Varistor - Test
SMCS - 4466-081
Illustration 1 g00677004
29/05/2018
Página 2 de 3
(CR1-CR6) Diodes
(CR7) Varistor
Ohmmeter
An ohmmeter can be used to check a varistor (CR7). Place an ohmmeter across the varistor. The
resistance should be a minimum of 15000 ohms. If the resistance is less than 15000 ohms, the varistor is
faulty.
Test Light
Illustration 2 g00555113
Test Light
Refer to the test light that is shown in Illustration 2. Follow these steps in order to test the varistor:
29/05/2018
Página 3 de 3
If the test light illuminates in either direction, there is a short in the varistor. Replace any faulty
varistors with varistors that have comparable operating characteristics. Include the following
information when a varistor is being ordered for replacement:
After the varistor has been replaced, verify that the strapping of the field winding lead is securely
wound on the shaft. Also, verify that the strapping of the field winding lead is securely tied.