Varmeca 30
Varmeca 30
Varmeca 30
06 / i
en
VARMECA 31/32
1
0-10 V/4-20 mA 2 10V L1
speed reference ADI1 L2
cal options or external reference) 3 Mains supply
en t o
4
0V L3
Motor PTC input
giv
ADI2
5 QS
e
24V
b Indication for local options 6
o
l i s t ser
ADIO3
u a
7
External fault input
n
DI01
ma nd u
Thi s
R+
e
8 Braking resistor
e
Run FWD/Stop DI2
t h Run REV/Stop
Selection of 0-10 V/4-20 mA
9
10
DI3
Dl4
R- (optional)
Jumper to be removed if
speed reference Fi Braking resistor option
11
Locking input +24V connected
12
ENA
13
Indicator relay RL1
14
RL2
VARMECA 30
Variable speed motors and geared motors
Parameter-setting manual
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
NOTE
LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest
technological developments. The information contained in this document may therefore be changed without notice.
CAUTION
For the user's own safety, this VARMECA 30 motor must be connected to an approved earth ( terminal).
If accidentally starting the installation is likely to cause a risk to personnel or the machines being driven, it is essential to supply
the equipment via a circuit-breaking device (power contactor) which can be controlled via an external safety system (emergency
stop, detection of errors on the installation).
The VARMECA 30 motor is fitted with safety devices which, in the event of a fault, control stopping and thus stop the motor. The
motor itself can become jammed for mechanical reasons. Voltage fluctuations, and in particular power cuts, may also cause the
motor to stop.
The removal of the causes of the shutdown can lead to restarting, which may be dangerous for certain machines or installations.
In such cases, it is essential that the user takes appropriate precautions against the motor restarting after an unscheduled stop.
The variable speed drive is designed to be able to supply a motor and the driven machine above its rated speed.
If the motor or the machine are not mechanically designed to withstand such speeds, the user may be exposed to serious danger
resulting from their mechanical deterioration. It is important that the user checks that the installation can withstand it, before
programming a high speed.
The variable speed drive which is the subject of this manual is designed to be integrated in an installation or an electrical machine,
and can under no circumstances be considered to be a safety device. It is therefore the responsibility of the machine manufacturer,
the designer of the installation or the user to take all necessary precautions to ensure that the system complies with current
standards, and to provide any devices required to ensure the safety of equipment and personnel.
LEROY-SOMER declines all responsibility in the event of the above recommendations not being observed.
2
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
en
modification of the clearance between components during
1 - General transportation and handling. Avoid touching the electronic
Depending on their degree of protection, VARMECA components and contact parts.
30þmotors may contain moving parts, as well as hot surfaces, VARMECA 30 motors contain parts which are sensitive to
during operation. electrostatic stress and may be easily damaged if handled
Unjustified removal of protection devices, incorrect use, faulty incorrectly. Electrical components must not be exposed to
installation or inappropriate operation could represent a mechanical damage or destruction (risks to health!).
serious risk to personnel and equipment.
For further information, consult the manual. 5 - Electrical connection
All work relating to transportation, installation, commissioning When work is performed on VARMECA 30 motors which are
and maintenance must be performed by experienced, qualified powered up, national accident prevention specifications must
personnel (see IEC 364 or CENELEC HD 384, or be respected.
DINþVDEþ0100, and also national specifications for The electrical installation must comply with the relevant
installation and accident prevention). specifications (for example conductor cross-sections,
In these basic safety instructions, protection via fused circuit-breaker, connection of protective
qualified personnel means persons competent to install, conductor). More detailed information is given in the manual.
mount, commission and operate the product and possessing Instructions for an installation which meets the requirements
the relevant qualifications. for electromagnetic compatibility, such as screening,
earthing, presence of filters and correct insertion of cables
2 - Use and conductors, are given in the documentation supplied with
VARMECA 30 motors are components designed for the VARMECA 30. These instructions must be followed in all
integration in installations or electrical machines. cases, even if the VARMECA 30 carries the CE mark.
When integrated in a machine, commissioning must not take Adherence to the limits given in the EMC legislation is the
place until it has been verified that the machine conforms with responsibility of the manufacturer of the installation or the
directive 89/392/EEC (Machinery Directive). machine.
It is also necessary to comply with standard EN 60204, which
stipulates in particular that electrical actuators (which include 6 - Operation
VARMECA 30) cannot be regarded as circuit-breaking Installations incorporating VARMECA 30 motors must be
devices and certainly not as isolating switches. fitted with additional protection and monitoring devices as laid
Commissioning can take place only if the requirements of the down in the current relevant safety regulations: law on
Electromagnetic Compatibility Directive (89/336/EEC, technical equipment, accident prevention regulations, etc.
modified by 92/31/EEC) are met. Modification of VARMECA 30 motors using control software
VARMECA 30 motors meet the requirements of the Low is permitted.
Voltage Directive 73/23/EEC, modified by 93/68/EEC. The Active parts of the device and live power connections must
harmonised standards of the DIN VDE 0160 series in not be touched immediately after the VARMECA 30 is
connection with standard VDE 0660, part 500 and EN 60146/ powered down, as the capacitors may still be charged. In view
VDE 0558 are also applicable. of this, the warnings fixed to VARMECA 30 motors must be
The technical characteristics and instructions concerning the observed. During operation, all doors and protective covers
connection conditions specified on the nameplate and in the must remain closed.
documentation provided must be observed without fail.
7 - Servicing and maintenance
3 - Transportation, storage Refer to the manufacturer's documentation.
All instructions concerning transportation, storage and correct
handling must be observed.
The climatic conditions specified in the technical manual must
be observed.
3
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
NOTE
4
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
CONTENTS
en
2.3 - Read mode ...................................................................................................................................................... 8
2.4 - Parameter-setting mode via "simplified" menu ................................................................................................ 9
2.5 - VARMECA 30 parameters accessible in SIMPLIFIED MENU ....................................................................... 10
2.6 - Parameter-setting mode via "advanced" menu .............................................................................................. 51
4 - APPENDIX ........................................................................................................................................................ 54
5
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
GENERAL INFORMATION
This manual is for use with software versions 1.00 (VMA 31/32), 2.20 (VMA 33/34), 2.00 (LCD KEYPAD console).
6
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
sure that it has not been damaged during transport.
Should damage have occurred please report it to those
responsible for its transport.
Inactive
Run Navigation
command between
Fault reset when menus or
or control via parameters and modification
Stop command console mode of parameter values
when control via console mode is selected
is selected
7
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
(1) Digital inputs 1, 2, 3, and 4 and the secure disable input are displayed on a single line according to their logic state (0 or 1) in the order (DI01, DI2, DI3, DI4, SDI1).
(2) Same as (1) for the output relay and brake control, in the order (relay, brake).
(3) Display of the timer on a single line (Year/Days, Hr/Min).
(4) Display of the energy meter on a single line (MWh, kWh).
8
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
Display on Switch Switch
power-up to Read menu to Simplified menu
Selection of
language
Choice: English
or French
Incrementation
or decrementation
of flashing digit
Parameter with mnemonics:
Modification Storage
9
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
10
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
centrifugal (eg: ventilation) overvoltage can occur on
the DC bus.
In this case, set 07 to the synchronous speed (1000 min–1
for 6 -pole, 1500 min–1 for 4-pole, 3000 min–1 for 2-pole,...).
(Address menu in manual reference 3997: 05.08)
0 to 480 V
08 MOTOR RATED VOLTAGE R-W – This is the rated voltage indicated on the motor nameplate.
(Address menu in manual reference 3997: 05.09)
0 to 1.00
11
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1
0-10 V/4-20 mA 10V L1 1
2 0-10 V/4-20 mA 10V L1
speed reference 2 Mains
(local options or external reference) 3
ADI1 L2 Mains supply speed reference ADI1 L2
3 supply
4
0V L3 (local options or external reference) 0V L3
Motor PTC input 4
ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 6
ADIO3 Indication for local options ADIO3
7 7
External fault input DI01 External fault input
8
DI01
R+ Run FWD/Stop +24V R+
Run FWD/Stop
8
DI2 Braking resistor 9 Braking
DI2
9 (optional) Run REV/Stop 10 resistor
Run REV/Stop DI3 R- DI3 R-
10 11 (optional)
Selection of 0-10 V/4-20 mA Dl4 Jumper to be removed if Selection of 0-10 V/4-20 mA +24V
Fi 12
speed reference Braking resistor option speed reference DI4
11 13
Locking input +24V connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
ADI2 terminal: • Configured as "PTC" input. If not used, connect to 0 V terminal with a jumper.
DI01 terminal: • Configured as "External fault" input. For the drive to operate, this terminal must be connected to the + 24 V.
DI4 terminal: • Configured as 0-10 V/4-20 mA selection. When it is connected to the + 24 V, terminal ADI1 is intended for a
4-20þmA signal. Without a jumper (factory setting), the speed reference will be 0-10 V.
Parameters specific to the configuration accessible with the LCD KEYPAD option (VMA 31/32 only) :
Parameter Name Type Factory setting Adjustment range
0-20 mA; 20-0 mA; 4-20 mA detect; 20-4 mA detect;
4-20 mA no detect; 20-4 mA no detect; 0-10 V;
Digital input
11 ADI1 MODE R-W 0-10 V
detect: with detection of 4 mA signal loss.
no detect: without detection of 4 mA signal loss.
12
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1 1
0-10 V/4-20 mA 10V L1 0-10 V/4-20 mA
2 Mains 2 10V L1
speed reference ADI1 L2 speed reference ADI1 Mains
3 supply 3 L2
(local options or external reference) 0V L3 (local options or external reference) 0V supply
4 4 L3
Motor PTC input ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
en
Indication for local options 6 6
ADIO3 Indication for local options ADIO3
7 7
DO NOT CONNECT DI01 External fault input DI01
8
R+ Braking Run FWD/Stop +24V
8 9 R+ Braking
Run FWD/Stop DI2 resistor DI2
Run REV/Stop
9
R- (optional) Run REV/Stop 10 resistor
DI3 DI3 R-
Selection of 0-10 V/4-20 mA
10 11 (optional)
Dl4
Jumper to be removed Selection of 0-10 V/4-20 mA +24V
speed reference Fi 12
11 if Braking resistor speed reference DI4
13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2
18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
ADI2 terminal:• Configured as "PTC" input. If not used, connect to 0 V terminal with a jumper.
DI01 terminal:• Configured as "External fault" input. For the drive to operate, this terminal must be connected to the + 24 V.
• In VMA 31/32 this terminal must not be used.
DI4 terminal: • Configured as 0-10 V/4-20 mA selection. When it is connected to the + 24 V, terminal ADI1 is intended for a
4-20þmA signal. Without a jumper (factory setting), the speed reference will be 0-10 V.
13
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1 1
10V L1 0-10 V/4-20 mA 10V L1
0-10 V/4-20 mA 2 Mains 2 Mains
ADI1 L2 speed reference ADI1 L2
speed reference 3 supply 3 supply
4
0V L3 4
0V L3
Motor PTC input ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 Indication for local options 6
ADIO3 ADIO3
7 7
Reverse DI01 Reverse DI01
8
R+ Forward +24V R+
8 Braking 9 Braking
Forward DI2 DI2
9 resistor Stop 10 resistor
Stop DI3 R- DI3 R-
10 11 (optional)
Selection of 0-10 V/4-20 mA Dl4 Jumper to be removed Selection of 0-10 V/4-20 mA +24V
12
speed reference Fi if Braking resistor speed reference DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
ADI2 terminal: • Configured as "PTC" input. If not used, connect to the 0 V terminal with a jumper.
DI4 terminal: • Configured as 0-10 V/4-20 mA selection. When it is connected to the + 24 V, terminal ADI1 is intended for a
4-20þmA signal. Without a jumper (factory setting), the speed reference will be 0-10 V.
With this configuration none of the parameters between 11 and 24 are opened.
14
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1 1
2 10V L1 2 10V L1
PID reference Mains PID reference ADI1 Mains
3
ADI1 L2 3 L2
supply 0V supply
4
0V L3 4 L3
PID feedback ADI2 PID feedback ADI2
en
5 QS 5 QS
24V 0V
Indication for local options 6 Indication for 6
ADIO3 ADIO3
local options
7 7
External fault input DI01 External fault input DI01
8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 resistor
Run REV/Stop DI3 R- DI3 R-
10 11 (optional)
PID enable Dl4 Jumper to be 0-10 V PID feedback +24V
11 12 0-10 V PID feedback
Fi PID enable DI4
Locking input
12
+24V removed if Braking (factory setting) 13 (factory setting)
ENA resistor option 0V SDI1
Locking input 14 0V
connected ADI2 SDI2
ADI2
+ 24 V 15 + 24 V
16 COM
13 Indicator relay
Indicator relay RL1 RL1C
14 4-20 mA PID feedback 17 4-20 mA PID feedback
RL2 0V 18
RL10 0V
Safety contact SD01
ADI2 19 ADI2
SD02
+ 24 V + 24 V
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal:•Configured as "External fault" input. For the drive to operate, this terminal must be connected to the + 24 V.
DI4 terminal:•Configured as "PID enable" input. When connected to the + 24 V, PID regulation is active, otherwise (contact open)
the VARMECA 30 is controlled using the speed reference via terminal ADI1.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Parameter Name Type Factory setting Adjustment range
0-20 mA; 20-0 mA; 4-20 mA detect; 20-4 mA detect;
4-20 mA no detect; 20-4 mA no detect; 0-10 V; Digital input
11 ADI1 MODE R-W 0-10 V detect: with detection of 4 mA signal loss
no detect: without detection of 4 mA signal loss
(Address menu in manual reference 3997: 7.06)
0-20 mA; 20-0 mA; 4-20 mA detect; 20-4 mA detect;
4-20 mA no detect; 20-4 mA no detect; 0-10 V; Digital input;
PTC sensors
12 ADI2 MODE R-W 0-10 V
detect: with detection of 4 mA signal loss
no detect: without detection of 4 mA signal loss
(Address menu in manual reference 3997: 7.11)
13
VMA31/32 VMA34/35
PROPORTIONAL GAIN PID R-W 200.0 0 to 320
150.0 (Address menu in manual reference 3997: 14.10)
14 PID INTEGRAL GAIN R-W VMA31/32 VMA34/35 0 to 320
20.0 20.0 (Address menu in manual reference 3997: 14.11)
15 PID DERIVATIVE GAIN R-W 0.00 0 to 2.50
(Address menu in manual reference 3997: 14.12)
16 PID OUTPUT UPPER LIMIT R-W 100.0% 0 to 100%
(Address menu in manual reference 3997: 14.13)
17 PID OUTPUT LOWER LIMIT R-W – 100.0% ± 100.0%
(Address menu in manual reference 3997: 14.14)
18 PID OUTPUT SCALE R-W 1.00 0 to 2.50
(Address menu in manual reference 3997: 14.15)
19 ADI2 INPUT SCALE R-W 1.00 0 to 2.50
(Address menu in manual reference 3997: 7.12)
20 Not used
± Limit (02) min–1
21 PRESET REFERENCE 7 RO +00000 min–1 PID reference expressed as speed
(Address menu in manual reference 3997: 14.20)
± Limit (02) min–1
22 PRESET REFERENCE 8 RO +00000 min–1 PID feedback expressed as speed
(Address menu in manual reference 3997: 14.21)
23 PID ERROR RO + 000.0% ± 100.0%
(Address menu in manual reference 3997: 14.19)
24 PID OUTPUT VALUE RO + 000.0 % ± 100.0%
(Address menu in manual reference 3997: 14.01)
15
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.5 - CONFIGURATION WITH 1 ANALOGUE REFERENCE + 3 PRESET REFERENCES (05 = 3VP + 1ANALOG.)
0-10 V/4-20 mA 1 1
2 10V L1 10V L1
speed reference Mains Speed reference
2 Mains
3
ADI1 L2 ADI1 L2
local options or external reference supply 3 supply
4
0V L3 0V L3
4
Motor PTC input ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 6
ADIO3 Indication for local options ADIO3
7 7
Speed selection DI01 Speed selection
8
DI01
8 R+ Braking Run FWD/Stop +24V R+
Run FWD/Stop DI2
9 Braking resistor
9 resistor DI2
Run REV/Stop DI3 R- Run REV/Stop 10 (optional)
10 DI3 R-
Speed selection 11
Dl4 Jumper to be removed Speed selection +24V
Fi 12
11 if Braking resistor DI4
13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
Indicator relay 13 16 COM
RL1 Indicator relay RL1C
14 17
RL2 RL10
18
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
Reference selection table
Note:
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
ADI2 terminal: • Configured as "PTC" input. If not used, connect to the 0 V terminal with a jumper.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Factory
Parameter Name Type setting Adjustment range
16
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.6 - CONFIGURATION WITH 1 ANALOGUE REFERENCE + 3 VMA31/32 PRESET REFERENCES WITH ESFR OPTION
(05 = 3VP 1ANA.ESFR)
Reference selection table
VARMECA 31/32
DI4 ADI03 Selection
0 0 0-10 V analogue reference (ADI1)
1
0-10 V/4-20 mA 10V L1
speed reference
2
ADI1 L2
Mains 1 0 Preset reference 2
en
3 supply
local options or external reference 0V L3
0 1 Preset reference 3
4
Electrical brake release ADI2
5 QS
24V
Speed selection 6
ADIO3 1 1 Preset reference 4
7
DO NOT CONNECT DI01
8 R+ Braking
Run FWD/Stop DI2 resistor
9
Run REV/Stop DI3 R- (optional)
10
Speed selection Dl4 Jumper to be removed
Fi if Braking resistor
11
Locking input +24V option connected
12
ENA
13
Indicator relay RL1
14
RL2
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
17
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1 1
10V L1 2 10V L1
Speed selection
2 Mains Speed selection ADI1 Mains
ADI1 L2 3 L2
3 supply 0V supply
4
0V L3 4 L3
Motor PTC input ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
6 6
0-10 V motor speed image ADIO3 0-10 V motor speed image ADIO3
7 7
Speed selection Speed selection DI01
DI01 8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 resistor
Run REV/Stop DI3 R- DI3 R-
10 11 (optional)
Speed selection Dl4 Jumper to be removed Speed selection +24V
12
Fi if Braking resistor DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
16 COM
13 Indicator relay
Indicator relay RL1 RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
ADI2 terminal: • Configured as "PTC" input. If not used, connect to 0 V terminal with a jumper.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Parameter Name Type Factory setting Adjustment range
18
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.8 - CONFIGURATION WITH REFERENCE CORRECTION VIA LOCAL BUTTON (05 = LOCAL/REM.)
1 1
2 10V L1 2 10V L1
Local button ADI1 Mains Local button ADI1 Mains
3 L2 3 L2
0V supply 0V supply
4 L3 4 L3
Remote reference ADI2 Remote reference ADI2
en
5 QS 5 QS
24V 0V
Indication for local options 6 Indication for local options 6
ADIO3 ADIO3
7 Selection of 0-10 V/4-20 mA 7
Selection of remote/correction DI01 DI01
for remote reference 8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking resistor
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 (optional)
Run REV/Stop DI3 R- DI3 R-
10 11
Selection of 0-10 V/4-20 mA Dl4 Jumper to be removed Selection of 0-10 V/4-20 mA +24V
12
for remote reference Fi if Braking resistor for remote reference DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal:• Configured as “Select Local Reference or Remote reference correction via local reference” input. When connected
to the + 24 V, the remote reference is not corrected.
DI4 terminal: • Configured as 0-10 V/4-20 mA selection. When it is connected to the + 24 V, terminal ADI2 is intended for a
4-20þmA signal. Without a jumper (factory setting), the remote reference will be 0-10 V.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Factory
Parameter Name Type setting Adjustment range
19
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.9 - CONFIGURATION WITH PRESET SPEED CORRECTION VIA LOCAL REFERENCE (05 = 2VP PROP. B)
1 1
2 10V L1 2 10V L1 Mains
Local reference ADI1 Mains Local reference
3 L2 3
ADI1 L2 power
0V supply
4 L3 4
0V L3 supply
Selection of preset speeds ADI2 Selection of preset speeds ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 Indication for local options 6
ADIO3 ADIO3
7 7
Disable correction DI01 Disable correction DI01
8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking resistor
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 (optional)
Run REV/Stop DI3 R- DI3 R-
10 11
Selection of 0-10 V/4-20 mA Dl4 Jumper to be removed +24V
Fi Selection of 0-10 V/4-20 mA 12
speed reference if Braking resistor DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
Note: • See manual 3776 for the connection and commissioning rules and the I/O characteristics
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and
+24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal: • Configured as "Select Preset Speeds or Correction of preset speeds via local reference".
When connected to the + 24 V the correction via the local reference affects the selected preset speed.
DI4 terminal: • Configured as 0-10 V/4-20 mA selection. When it is connected to the + 24 V, terminal ADI1 is intended for a
4-20þmA signal. Without a jumper (factory setting), the speed reference will be 0-10 V.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Parameter Factory
Name Type Adjustment range
setting
Inactive; Active
Selection of preset speeds
11 BIT 0 SEL. R.P./DIG. INPUT RO Inactive ADI2 Selection
0 Preset reference 1
1 Preset reference 2
20
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.10 - REGULATION OF A PRESSURE WITH THE INTEGRATED PI LOOP - PI REFERENCE USING LOCAL OR
EXTERNAL REFERENCE (05 = VENT PUMPS)
1 1
2 10V L1 10V L1
PID reference ADI1 Mains PID reference 2 Mains
3 L2 ADI1 L2
supply 3
en
0V L3 0V supply
PID feedback
4 4 L3
ADI2 PID feedback ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 6
ADIO3 Indication for local options ADIO3
Reference 0-10V or 4-20mA 7 7
DI01 Reference 0-10V or 4-20mA DI01
8
8 R+ Braking resistor +24V R+
Run FWD / Stop 9 Braking resistor
DI2 Run FWD / Stop DI2
9 (optional) 10 (optional)
DI3 R- DI3 R-
10 11
PID enable Dl4 Jumper to be 0-10 V PID feedback +24V
11
Lack of water safety +24V Fi removed if Braking 0V PID enable 12 0-10 V PID feedback
12 DI4
ENA 13 0V
resistor option ADI2 SDI1
Lack of water safety 14
ADI2
connected + 24 V SDI2
+ 24 V
15
Fault indicator relay 13 4-20 mA PID feedback COM
16
14
COM (factory setting) Fault indicator relay RL1C 4-20 mA PID feedback
17 (factory setting)
RL1C 0V RL10
18 0V
ADI2 Safety contact SD01
19 ADI2
+ 24 V SD02
+ 24 V
Note:
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal:• Configured as input, you can select the type of the reference pressure. The reference is in 0-10V if the input is
connected to +24V.
DI4 terminal: • Configured as "PID enable" input. When connected to the + 24 V, PID regulation is active, otherwise (contact open)
the VARMECA 30 is controlled using the speed reference via terminal ADI1.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
21
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
22
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
Automatic Run/Stop:
- On a run command, the power pump assembly will 2.1 - Set the operating point
adjust the flow so as to maintain a constant pressure - Max. flow (addr. 0.02) depends on the pump
throughout the system. When the flow ceases, the characteristics.
pump stops automatically. The pump restarts as soon
as the pressure falls below its working threshold. 2.2 - Give a run command and check the direction of
If draining occurs, the system stops in "User 1" fault rotation, if necessary reverse two wires on the motor
mode. phases.
The drive controls the flow according to the speed reference. DO NOT MODIFY THE RAMPS
This setting avoids altering the precision of regulation
2 - Pump with pressure sensor
2.4 - Select the "Vent. Pumps" configuration (addr. 0.05)
2.1 - The inverter adjusts speed to control the power
2.5 - Choice of reference type (adress 0.11)
- Programming using the LCD KEYPAD console
- Programming using the local operator display PAD VMA 30 2.6 - Choice of sensor type (addr. 0.12)
- Access to the user menu (menu 00).
Once the configuration has been set (addr. 0.05) the drive
opens the parameters linked to the application. Help with diagnostics (section 2.3.2)
Note: after modification of the parameters, the address 0.05 In this read mode it is possible to display the state of the
turns "FREE" analogue and digital inputs, the motor data (speed, current,
frequency, voltage), the timers and energy meters and also
2.2 - Possible displays the list of the last ten faults.
- Reference pressure (addr. 0.19)
- Actual pressure (addr. 0.20) Note:
- Pump rotation speed (addr. 0.21) - to activate the reading mode, press 5’s on the "M" button;
- Possibility of increasing time before stop (addr. 16.15)
2.3 - Emergency mode (factory adjustment : 25s)
If the pressure regulation malfunctions, you can revert to
speed regulation without using a parameter-setting tool,
simply by opening terminal DI4. The pressure reference
becomes a speed reference and can be used to adjust the
pump flow.
23
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.11 - CONFIGURATION OF TORQUE CONTROL WITH SPEED LIMITING (05 = TORQUE CNTRL.)
0-10 V/4-20 mA 1 1
10V L1 10V L1 Mains
speed reference 2 Mains Speed reference 2
3
ADI1 L2 (0-10 V/4-20 mA) 3
ADI1 L2 power
(local options or external reference) supply
4
0V L3 4
0V L3 supply
Torque reference Torque reference
ADI2 (0-10 V/4-20 mA) ADI2
0-10 V/4-20 mA 5 QS 5 QS
24V 0V
Indication for local options 6 Indication for local options 6
ADIO3 ADIO3
7 7
External fault input DI01 External fault input DI01
8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking resistor
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 (optional)
Run REV/Stop DI3 R- DI3 R-
10 11
Selection of speed/torque Dl4 Jumper to be removed +24V
Selection of speed/torque 12
Fi if Braking resistor DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
16 COM
13 Indicator relay
Indicator relay RL1 RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
Selection table
DI4 Selection
0 Speed-reference control via ADI1
Torque-reference control via ADI2
1
and speed limiting via parameter 13
Note: • See manual 3776 for the connection and commissioning rules and the I/O characteristics
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and
+24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal:• Configured as "External fault" input. For the drive to operate, this terminal must be connected to the + 24 V.
DI4 terminal: • Configured as "Selection of speed control or torque control with speed limiting". When connected to the + 24 V, the
VARMECA 30 is in torque control with speed limiting.
• Do not change from speed regulation to torque regulation when there is an active run command:
Parameters specific to the configuration accessible with the LCD KEYPAD option.
24
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.12 - FASTER/SLOWER CONFIGURATION (05 = FASTER/SLOWER, ESFR) IN VMA 31/32 WITH ESFR OPTION
(05 = FASTER/SLOWER) IN VMA 33/34 WITH OR WITHOUT ESFR OPTION
en
0V supply supply
4 L3 4
0V L3
Electrical brake release ADI2 Motor PTC input ADI2
5 QS 5 QS
24V 0V
Selection of reduced speed 6
Selection of reduced speed 6
ADIO3 ADIO3
7 7
DO NOT CONNECT DI01 Electrical brake release DI01
8
R+ Run FWD/Stop +24V R+
8 Braking 9 Braking resistor
Run FWD/Stop DI2 DI2
9 resistor Run REV/Stop 10 (optional)
Run REV/Stop DI3 R- DI3 R-
10 11
Acceleration input Dl4 Jumper to be removed +24V
Acceleration input 12
Fi if Braking resistor DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay Indicator relay RL1C
14
RL1 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Parameter Factory
Name Type Adjustment range
setting
± 32000 min-1
0.11 PRESET REFERENCE 2 R-W 0000 Reduced speed setting
(Address menu in manual reference 3997: 1.22)
0.12 to 0.24 NOT USED
25
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
2.5.2.13 - FASTER/SLOWER CONFIGURATION (05 = FASTER/SLOWER, NO ESFR) IN VMA 31/32 WITHOUT ESFR OPTION
VARMECA 31/32
13
Indicator relay RL1
14
RL2
Note: For single-phase versions, the power supply is connected to terminals L and N.
Parameters specific to the configuration accessible with the LCD KEYPAD option:
Parameter Factory
Name Type Adjustment range
setting
± 32000 min-1
0.11 PRESET REFERENCE 2 R-W 0000 Reduced speed setting
(Address menu in manual reference 3997: 1.22)
Description of operation of the faster/slower command:
This function is used to stabilise the speed at all levels between min. speed and max. speed.
The command operates by means of two contacts:
- a Run/Stop, Forward or Reverse contact which is used for starting up to a min. speed, and for maintaining intermediate speeds,
(DI2, DI3)
- an acceleration contact which is used to reach the max. speed (terminal DI4)
An additional input is used to reduce the max. speed (when ADI03 has been disabled). The faster/slower function can be used at
any point down to the reduced speed. The reduced speed can be set in parameter 0.11.
Diagram:
Max.
speed
Speed
Min.
speed
Time
DI2 or DI3 1
input
(maintain speed) 0
DI4 input 1
(acceleration)
0
26
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
1 1
10V L1 Main reference 2 10V L1
Main reference 2 Mains supply Mains
ADI1 L2 0-10 V or 4-20 mA 3
ADI1 L2
0-10 V or 4-20 mA 3 supply
4
0V L3 4
0V L3
Faster ADI2
en
Faster ADI2
5 QS 5 QS
24V 0V
Indication for local options 6 Indication for local options 6
ADIO3 ADIO3
7 7
External fault input DI01 External fault input DI01
8
R+ Run FWD/Stop +24V R+
8 Braking resistor 9 Braking resistor
Run FWD/Stop DI2 DI2
9 (optional) Run REV/Stop 10 (optional)
Run REV/Stop DI3 R- DI3 R-
10 11
Faster Dl4 Jumper to be removed if +24V
12
Fi Braking resistor Faster DI4
11 13
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay RL1 Indicator relay RL1C
14 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal:• Configured as "External fault" input. For the drive to operate, this terminal must be connected to the + 24 V.
Parameters specific to the configuration accessible with the LCD KEYPAD option.
27
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
28
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE PADVMA30
LCD KEYPAD
KEYPAD
MICRO CONSOLE
1 1
2 10V L1 2 10V L1
ADI1 Mains ADI1 Mains
3 L2 3 L2
0V supply 0V supply
4 L3 4 L3
en
Motor PTC input ADI2 Motor PTC input ADI2
5 QS 5
24V 0V
0-10 V motor speed image 6 0-10 V motor speed image 6
ADIO3 ADIO3
7 Zero speed output
External fault DI01 DI01
R+ +24V R+
8 Braking resistor Braking resistor
DI2 DI2
9 (optional) (optional)
DI3 R- DI3 R-
10
Dl4 Jumper to be removed if +24V
Fi DI4
11 Braking resistor
Locking input +24V option connected SDI1
12 Locking input 14
ENA SDI2
15
13 16 COM
Indicator relay Indicator relay RL1C
14
RL1 17
RL2 18
RL10
Safety contact 19
SD01
SD02
Note: For single-phase versions, the power supply is connected to terminals L and N.
• See manual 3776 for the connection and commissioning rules and the I/O characteristics.
• The parameters must be set with the VARMECA 30 locked, i.e. jumper between terminals SDI1 and SDI2 or ENA and +24V open.
• The VARMECA 30 operates in positive logic.
DI01 terminal (VMA 31/32) : Configured as "External fault" input. For the drive to operate, this terminal must be connected
to the + 24 V.
The local control options (B31/32 - BMA 31/32 - BMAVAR 31/32 - B 33/34 - BMA 33/34 - BMAVAR 33/34) are not
compatible with the use of the PAD VMA30 option
The PADVMA30 operator display consists of a display unit, three control buttons and three parameter-setting keys.
29
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE PADVMA30
LCD KEYPAD
KEYPAD
MICRO CONSOLE
Factory
Parameter Name Type setting Adjustment range
POWER-UP KEYPAD rSEt: at zero; Prec: identical to the reference at the time of
11 CONTROL MODE R-W rSEt powering down; Pr1: identical to RP1
REFERENCE
REFERENCE ON POWER-UP
12 (RP1) R-W 0 ± Maximum limit (02) min-1
30
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE PADVMA30
LCD KEYPAD
KEYPAD
MICRO CONSOLE
VMA 31/32
en
- Connect the option to the drive via the RJ45 socket.
- Lock the VMA 31/32 using terminals 11-12, then power it up. The display must show "inh".
- Access parameter 65 (return to factory settings) using the keys for scrolling through the parameters.
- Change the parameter to "ON" then save. After a few seconds, the parameter returns to "OFF".
VMA 33/34
- Lock the VMA 33/34 using terminals SD11 and SD12, then power it up. The display must show "inh".
- Access parameter 05 (selection of the configuration) using the keys for scrolling through the parameters.
31
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE PADVMA30
LCD KEYPAD
KEYPAD
MICRO CONSOLE
INFORMATION ON OPERATION
This provides the user with information on the status of the drive when it is stopped or in operation.
Comment
Auto/tunE - Auto and tunE alternately displayed
- Autocalibration phase in progress
dEc - Deceleration in progress after a stop command
inh - The drive is locked and cannot start the motor
- Freewheel stop
rdY - The drive is unlocked and waiting for a command
- The motor is ready to operate
StoP - The drive maintains the motor torque at zero speed
triP - The drive has switched to protective mode
- Alternating display of triP and the fault code (for the meaning of the code, see section 5.2)
Alar./USrx - Alternating display of Alar. and USrx, where x is the customer fault number (1 to 4).
- Alarms enabled by 10.54 to 10.57 (refer to the extended functions manual ref. 3997)
If the drive switches to protective mode, the drive output bridge is inactive and the drive no longer controls the motor.
The display alternately indicates "triP" and the fault code.
All the faults indicated by the display are listed in the table in section 3: Switching to protective mode - Diagnostics.
CORRESPONDANCE BETWEEN THE CONFIGURATIONS OF THE PXLCD CONSOLE AND THE PADVMA30
DISPLAY UNIT
32
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
difference between these modes is the method
used to identify the motor parameters, particularly
the stator resistance. These parameters vary with
the temperature, and as they are essential for
obtaining optimum performance levels, the
machine cycle must be taken into account for
selecting the most appropriate mode. U/F linear
and U/F Quadratic modes correspond to a control
mode by a U/F ratio. This ratio is linear in U/F mode
and quadratic in U/F Quadratic mode.
33
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
08
2
Boost
( 26 )
61 61 Motor
2 frequency
VMA 33/34 Open loop: The drive is in open loop control. Open
loop control mode is defined by the setting of
parameter 26.
CL.LP vector: The drive is controlling an induction
motor in closed loop flux vector control. The type of
encoder and control mode are defined by
parameters 26 to 33.
Servo: The drive is controlling a synchronous
motor. The type of encoder and control mode are
defined by parameters 26 to 33.
25 DRIVE MODE R-W OPEN LOOP
This parameter is used to select the control mode.
A return to factory settings procedure does not
modify the operating mode.
The operating mode can only be selected when the
drive is stopped.
Note: The change from open loop mode (Open
loop) to closed loop mode (CL.LP vector), or vice-
versa, initiates a return to factory settings of
parameters 40 (brake apply frequency or brake
apply speed) and 41 (magnetisation time delay/
speed threshold).
(Address menu in manual reference 3997: 11.31)
34
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
• If 25 = Open Loop
Parameter Name Type Factory setting Adjustment range
SR: EACH Run, SR: NOT Meas, U/F linear,
SR: 1st RUN, SR: POWER-UP, U/F Quadrat.
en
particularly the stator resistance. As these
parameters vary with the temperature, and are
essential for obtaining optimum performance
levels, the machine cycle must be taken into
account for selecting the most appropriate
mode. U/F and QUASI SQUARE modes
correspond to a control mode by a U/F ratio.
This ratio is linear in U/F mode and quadratic in
QUASI SQUARE mode.
35
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
• If 25 = Open Loop and 26 = SR: EACH Run, SR: NOT Meas, SR: 1st RUN, SR/POWER-UP, U/F: Quadrat.
Parameter Name Type Factory setting Adjustment range
27 to 30 Not used
0 to 25
Due to a certain number of internal drive
factors, oscillations may occur in the following
cases:
- Frequency regulation with current limiting
around the rated frequency and on load impacts
- Torque regulation on machines with a low load
and around the rated speed
31 CURRENT PROPORT. GAIN R-W 20
- on a mains supply break or on a controlled
deceleration ramp when DC bus regulation is
requested.
To reduce these oscillations, we recommend
that you first:
- Increase the proportional gain 31
- Then reduce the integral gain 32
(Address menu in manual reference 3997: 4.13)
0 to 25
32 CURRENT INTEGRAL GAIN R-W 40
(Address menu in manual reference 3997: 4.14)
33 to 35 Not used
Motor voltage
29 BOOST ON U/F RATIO R-W 0% 08
08
2
Boost
( 26 )
61 61 Motor
2 frequency
36
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
• If 25 = BF Vector
Parameter Name Type Factory setting Adjustment range
INCREMENTAL; INCREM.FD;
INCREM.FWD/REV;
INCREM. UVW; HALL EFFECT; NO MODE 1
NO MODE 2; NO MODE 3; NO MODE 4
INCREMENTAL: Quadrature incremental
en
encoder.
INCREM.FD: Incremental encoder with
26 SENSOR TYPE R-W INCREMENTAL Frequency/Direction output.
INCREM.FWD/REV: Incremental encoder with
FWD/REV outputs.
INCREM. UVW: Incremental encoder with
commutation channels.
HALL EFFECT: Hall effect sensor.
NO MODE 1 to 4: sensorless mode 1 to mode 4.
(Address menu in manual reference 3997: 3.38)
0 to 32000
Used to configure the number of points per
27 NO. PTS/ENCODER REV. R-W 1024 ppr encoder revolution. Converts the encoder input
into a speed.
(Address menu in manual reference 3997: 3.34)
0 to 16 ms
This parameter is used to insert a moving
average filter on the encoder speed feedback.
This is particularly useful for attenuating the
current demand when the load has a high
inertia and when a high gain is necessary on the
28 ENCODER FILTER R-W 0 ms speed loop. If the filter is not enabled under
these conditions, the speed loop output may
change continuously from one current limit to
another, blocking the integral function of the
speed loop.
The filter is inactive if 28 = 0.
(Address menu in manual reference 3997: 3.42)
0 to 32000
Adjusts the stability of the motor speed in the
event of sudden variations in the reference.
Increase the proportional gain until vibrations
29 SPEED PROPORT. GAIN R-W 200 occur in the motor, then reduce the value by 20
to 30%, checking that the motor remains stable
in the event of sudden variations in speed, both
at no load and on load.
(Address menu in manual reference 3997: 3.10)
0 to 32000
Adjusts the stability of the motor speed on load
impact.
30 SPEED INTEGRAL GAIN R-W 100 Increase the integral gain so that the same
speed is obtained on load and at no load in the
event of load impact.
(Address menu in manual reference 3997: 3.11)
37
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
Requires a servomotor.
38
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
towards the ESFR option.
(Address menu in manual reference 3997: 12.41)
• If 36 = Disabled
Parameter Name Type Factory setting Adjustment range
37 to 44 Not used
39
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
0 to 25 s
TIME DELAY BEFORE RAMP This time delay is triggered when brake control is
42 R-W 0.1 s enabled. It is used to allow time for the brake to
UNLOCK
release before unlocking the ramp.
(Address menu in manual reference 3997: 12.47)
43 Not used
44 Not used
45 Not used
40
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
THRESHOLD detected.
Note: This parameter is not active in closed loop
mode with software versions V2.0.
(Address menu in manual reference 3997: 12.43)
39 Not used
0 to 100 min-1
Used to adjust the frequency or speed threshold at
which brake control will be disabled. This threshold
enables the brake to be applied before zero speed
so as to avoid load veering while the brake is being
engaged.
If the frequency or speed drops below this threshold
40 BRAKE APPLY Vt THRESHOLD R-W 5 min-1 when no stop request has been made (change of
direction of rotation), brake control will remain
activated. This exception can be used to avoid the
brake being engaged as the speed passes though
zero.
Note: This parameter is not active in closed loop
mode with software versions V2.0.
(Address menu in manual reference 3997: 12.45)
This time delay delays the brake apply command in
relation to passing below the minimum speed
threshold (40). It is useful for avoiding repeated
41 BRAKE APPLY TIME DELAY R-W 0.3 s
application and release of the brake during
operation around zero speed.
(Address menu in manual reference: 12.46)
0 to 25 s
TIME DELAY BEFORE RAMP This time delay is triggered when brake control is
42 R-W 1.00 s enabled. It is used to allow time for the brake to
UNLOCK
release before unlocking the ramp.
(Address menu in manual reference 3997: 12.47)
0 to 25 s
This time delay is used to maintain the torque at
standstill while the brake is applied. When this time
43 BRAKE APPLY TIME DELAY R-W 1.00 s delay has elapsed, the drive output is deactivated.
Note: This parameter is not active in closed loop
mode with software versions V2.0.
(Address menu in manual reference 3997: 12.48)
Disabled; Enabled
41
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
42
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
Ref. reached: Reference reached output
50 DIO1 CONTROL R-W Any Min. speed: Minimum speed output
Rated load reached: Rated load reached output
Drive active: Drive active output
Gen. alarm: Drive general alarm output
Current lim: Current limit output
Jogging input: Jog input
Reset input: Reset input
Any: Any assignment
(Address menu in manual reference 3997: 8.41)
0 to 16000 min–1
51 JOG REFERENCE R-W 45 min–1 Operating frequency when the jog operation input
has been selected.
(Address menu in manual reference 3997: 1.05)
+ ref. only; + and – ref.
43
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
44
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
s, the motor demagnetisation time.
Motor
speed
t
Stop
Freewheel stopping time
Time
t
58 STOPPING MODE R-W Ramp Stop
Deceleration rdY Time
1 sec
ramp
t
Stop
Deceleration Time
ramp
Motor
current
DC injection rdY
Motor current
45
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
t
Stop
Braked stop
Motor Time
current
rdY
Motor Low frequency DC
current current injection injection
Delayed DC: The drive decelerates the motor by
58
(continued) imposing DC current for 1 second.
Motor
speed
t
Stop
Braked stop Time
Motor
current
DC injection rdY
Motor
(Address menu in manual reference 3997: 6.01)
Disabled; 2 directions; Clockwise; Anti-clockwise
46
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
4 kHz rise and the level of radio-frequency interference
(VMA 31/32) emission, and reduces the starting torque.
If the temperature becomes too high, the drive can
reduce the switching frequency selected by the
user.
(Address menu in manual reference 3997: 5.18)
0 to 400 Hz
47
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
No: No action.
CAUTION:
Lock the drive before changing 65.
No: No return to factory settings procedure is
RETURN TO FACTORY performed.
65 R-W No
SETTINGS Yes: Reconfigures the drive to factory settings.
Parameters relating to min. speed, max. speed,
motor parameters, the motor control mode and the
motor rating are not affected by the return to
factory settings.
(Address menu in manual reference 3997: 11.43)
48
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
Security code:
en
equivalent to the value of 66.
In read mode, this parameter is always at 0.
(Address menu in manual reference 3997: 11.30)
49
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
50
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
COMMISSIONING USING THE LCD KEYPAD MICRO CONSOLE
en
Mode not currently available
51
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
SWITCHING TO PROTECTIVE MODE – DIAGNOSTICS
52
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
SWITCHING TO PROTECTIVE MODE – DIAGNOSTICS
en
already connected, reduce its value (within the permitted
limit)
OU DC bus voltage DC bus overvoltage • Check that the mains supply is not disturbed
• Check the motor insulation
• Set a longer deceleration time in 04
• Check the deceleration mode
Ph Loss of phase No motor current with brake enabled • Reduce parameter 38
• Adapt the drive power to that of the motor
rS Stator resis. Stator resistance measurement fault • Check the connection of the motor cables
• Check that the serial link cable is not damaged or
SCL COM loss Serial link fault incorrectly connected
• Check 1163 = 0
Secd Sec. disable inp. Secure disable input fault • Give a stop command before unlocking the drive
• Check the motor load
• Reduce the overload level
th Motor sensor Motor sensor trip • Check the motor cooling and the ambient temperature
• Check the wiring of terminal ADI2 on the control terminal
block
• Check the wiring of terminal DI01 / underpresssure fault in
tr 01 User 1 User fault 1 via logic input config 05 = VENT. PUMPS
tr 02 User 2 User fault 2 high internal temperature • Check the cooling of the VMA 30
tr 03 User 3 User fault 3 via logic input
tr 04 User 4 User fault 4 via logic input
tr 05 User 5 User fault 5 via serial link
tr 06 User 6 User fault 6 via serial link
tr 07 User 7 User fault 7 via serial link
tr 08 User 8 User fault 8 via serial link
tr 09 User 9 User fault 9 via serial link
tr 10 User 10 User fault 10 via serial link
The measured position does not vary
(the encoder is incorrectly connected
enC2 Encoder rot. or not supplied with power or the shaft
is not turning)
The a, b, a\, b\ signals are the wrong
rot Invers. A/B • Check the encoder wiring
way round
The u, v, w switching signals are the
tun 3 Invers. UVW • Check the encoder wiring
wrong way round
Some signals are present, but U is
tun 4 Cal U encod. missing • Check the encoder wiring
Some signals are present, but V is
tun 5 Cal V encod. missing
Some signals are present, but W is
tun 6 Cal W encod. missing
The number of pairs of poles set is
incorrect (the revolutions measured
mechanically with a and b, and
tun 7 No. of poles • Check parameter 62
electrically with u, v and w, are
inconsistent, given the number of
pairs of poles entered)
• Drive set to fault mode during the autocalibration phase
• The Stop key has been pressed
tun E Autocalibr. Autocalibration error • The SDI contact has been opened during the
autocalibration phase
UU BUS Underv. DC bus undervoltage • Check the mains supply
* When a no-load test is carried out (i.e. with the motor disconnected), motor operation may appear unstable. This instability manifests
itself in the form of vibration and, in extreme cases, in a fault (overload, overcurrent or braking resistor overload). However, the instability
disappears as soon as the motor is loaded. To remove this instability during a no-load test, set parameter 5.13 to DYNAMIC. To return to
normal machine operating conditions, reset parameter 5.13 to FIXED.
If the problem persists, contact Leroy-Somer.
53
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
4 - APPENDIX
54
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = STANDARD
Parameter Parameter definition Factory setting
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.10 ADI1 input destination 01.36
07.11 ADI2 mode PTC sensor
en
07.14 ADI2 input destination 00.00
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert yes
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert yes
08.21 DIO1 input destination 10.61
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 09.30
08.31 Selection of terminal DIO1 as input or output input
09.33 Decimal output destination 07.06
09.34 Binary sum offset 4 VMA 33/34
05 = STANDARD + JOG
Parameter Parameter definition Factory setting
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Jog Run/Stop
06.43 Origin of commands via terminals
07.10 ADI1 input destination 01.36
07.11 ADI2 mode PTC sensor
07.14 ADI2 input destination 00.00
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert yes
08.21 DIO1 input destination 06.32
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.39
08.24 DI4 input destination 09.30
08.31 Selection of terminal DIO1 as input or output input
09.33 Decimal output destination 07.06
09.34 Binary sum offset 4 VMA 33/34
55
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = STANDARD + PID
Parameter Parameter definition Factory setting
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.09 ADI1 input invert no
07.10 ADI1 input destination 01.27
07.11 ADI2 mode 0-10V
07.14 ADI2 input destination 01.28
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert yes
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 10.61
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 14.08
08.31 Selection of terminal DIO1 as input or output input
14.02 Main reference source 01.27
14.03 PID reference source 01.27
14.04 PID feedback source 01.28
14.16 PID destination 01.36 VMA 33/34
05 = 3VP + 1ANALOG.
Parameter Parameter definition Factory setting
01.14 Selection of references ana. input 1
01.15 Selection of preset frequencies via terminals
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert no
07.10 ADI1 input destination 01.36
07.11 ADI2 mode PTC sensor
07.14 ADI2 input destination 00.00
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 01.46
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 01.45
08.31 Selection of terminal DIO1 as input or output input VMA 33/34
56
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
en
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert no
07.10 ADI1 input destination 01.36
07.11 ADI2 mode Digital input
07.14 ADI2 input destination 12.51
07.15 ADIO3 mode Digital input
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 01.46
08.11 Digital input or output DI01 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 12.40
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 01.45
08.31 Selection of terminal DIO1 as input or output output
05 = 8VP
Parameter Parameter definition Factory setting
01.14 Selection of references preset ref.
01.15 Selection of preset frequencies via terminals
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode Digital input
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert no
07.10 ADI1 input destination 01.46
07.11 ADI2 mode PTC sensor
07.14 ADI2 input destination 00.00
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DI01 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 01.47
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 01.45
08.31 Selection of terminal DIO1 as input or output input VMA 33/34
57
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = LOCAL/REM
Parameter Parameter definition Factory setting
01.04 Reference offset 0
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert yes
07.10 ADI1 input destination 01.38
07.11 ADI2 mode 0-10V
07.12 ADI2 input scaling 1.0
07.13 ADI2 input invert no
07.14 ADI2 input destination 01.36
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert yes
08.21 DIO1 input destination 01.09
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 09.30
08.31 Selection of terminal DIO1 as input or output input
09.33 Decimal output destination 07.11
09.34 Binary sum offset 4 VMA 33/34
58
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = 2VP PROP.B
Parameter Parameter definition Factory setting
01.04 Reference offset 0
01.14 Selection of references preset ref.
01.15 Selection of preset speeds via terminals
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
en
07.06 ADI1 mode 0-10V
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert yes
07.10 ADI1 input destination 01.38
07.11 ADI2 mode Digital input
07.12 ADI2 input scaling 1.0
07.13 ADI2 input invert no
07.14 ADI2 input destination 01.45
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DIO1 invert yes
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert yes
08.21 DIO1 input destination 01.09
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 09.30
08.31 Selection of terminal DIO1 as input or output input
09.33 Decimal output destination 07.06
09.34 Binary sum offset 4 VMA 33/34
59
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = PUMPS VENT
Parameter Parameter definition Factory setting
01.14 Selection of references via terminals
01.24 RP 4 2
01.26 RP 6 5
1.27 RP 7 1
02.04 Deceleration mode Fix ramp
02.11 Acceleration 1 0.1 0.5
02.20 Selection of deceleration ramp Decel. N°5
02.21 Deceleration ramp 1 5
02.25 Deceleration 5 0.1 0.5
05.12 Autotune No
07.08 ADI1 input scaling 0.99
07.10 ADI1 input destination 1224
07.11 ADI2 mode 4-20mA detect
07.14 ADI2 input destination 124
07.62 Potentiometer input scaling 0.9
07.64 Potentiometer input destination 1264
07.68 Source potentiometer 701
08.11 Digital input or output DI01 invert No
08.14 Digital input DI4 invert No
08.21 DIO1 input destination 931
08.22 DI2 input destination 0
08.23 DI3 input destination 0
08.24 DI4 input destination 1408
09.04 No. 1 AND function source 1 630
09.06 No. 1 AND function source 2 1630
09.14 No. 2 AND function source 1 1201
09.16 No. 2 AND function source 2 1002
09.34 Binary sum offset 2
09.64 No. 3 AND function source 1 1202
09.66 No. 3 AND function source 2 1004
09.70 No. 4 AND function destination 630
09.74 No. 4 AND function source 1 1641
09.76 No. 4 AND function source 2 802
10.35 Automatic fault erasure timer 2
10.70 Automatic under voltage reset Yes
11.01 Determination of 46 622
11.02 Determination of 47 623
11.03 Determination of 48 762
11.04 Determination of 49 1020
11.05 Determination of 50 1021
11.06 Determination of 51 1022
11.07 Determination of 52 1023
11.08 Determination of 53 1024
11.09 Determination of 54 1025
11.10 Determination of 55 1026
11.11 Determination of 56 1027
11.12 Determination of 57 1402
11.13 Determination of 58 1403
12.03 Threshold detector 1 source 124
12.04 Threshold detector 1 threshold 10
12.05 Threshold detector 1 hysteresis 2
12.06 Threshold detector 1 invert Yes
12.23 Threshold detector 2 source 702
12.25 Threshold detector 2 hysteresis 0.5
12.27 Threshold detector 2 destination 0
12.28 Variable selector 2 source 1 126
12.29 Variable selector 2 source 2 127
12.31 Destination sortie bloc 2 220 VMA 33/34
60
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = PUMPS (continued)
Parameter Parameter definition Factory setting
12.63 Threshold detector 3 source 702
12.65 Threshold detector 3 hysteresis 0.5
12.66 Threshold detector 3 output inversion Yes
14.02 Main reference source 701
14.03 PID reference source 701
en
14.04 PID feedback source 124
14.09 PID enable condition 901
14.10 PID proportional gain 100 150
14.11 PID integral gain 80 75
14.14 PID minimum limit 0
14.16 PID output destination 136
14.53 Sensor read coefficient 10
16.02 Timer 1 source 902
16.05 Timer 1 value 10
16.12 Timer 2 source 961
16.15 Timer 2 value (timed stop on Fmin) 25
16.22 Input source timer 3 1631
16.25 Timer set 3 3
16.32 Input source timer 4 1202
16.35 Timer set 4 10
16.39 Output destination 4 1230
16.42 Input ON auto maintain 1 1261
16.43 Input OFF auto maintain 1 1611
16.52 Input ON auto maintain 2 1601
16.53 Input OFF auto maintain 2 804
16.54 Input inversion OFF set 2 Yes
16.59 Output destination auto maintain 2 1061
16.62 Input ON auto maintain 3 1631
16.63 Input OFF auto maintain 3 1671
16.64 Input inversion OFF set 3 Yes
16.69 Output destination auto maintain 3 142
16.72 Input ON auto maintain 4 804
16.73 Input OFF auto maintain 4 1202
16.74 Input inversion OFF set 4 Yes VMA 33/34
05 = TORQUE CTRL
Parameter Parameter definition Factory setting
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.10 ADI1 input destination 01.36
07.11 ADI2 mode 0-10V
07.14 ADI2 input destination 04.08
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output inversion no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select interlock
08.11 Digital input or output DI01 invert yes
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 10.61
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 04.11
08.31 Selection of terminal DIO1 as input or output input VMA 33/34
61
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
62
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
en
06.04 Start/stop logic select Latched Run/Stop
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.08 ADI1 input scaling 1.0
07.09 ADI1 input invert no
07.10 ADI1 input destination 01.36
07.11 ADI2 mode Digital input PTC sensor
07.14 ADI2 input destination 12.51 00.00
07.15 ADIO3 mode Digital input
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert yes
07.18 ADIO3 input destination/output source 01.45
08.10 Drive enable mode select lock
08.11 Digital input or output DI01 invert no
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 12.40 12.51
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 00.00
08.31 Selection of terminal DIO1 as input or output output
09.04 No. 1 AND function source 1 08.04
09.05 No. 1 AND function source 1 invert yes
09.06 No. 1 AND function source 2 09.02
09.07 No. 1 AND function source 2 invert yes
09.08 No. 1 AND output invert no
09.10 No. 1 AND output destination 02.03
09.14 No. 2 AND function source 1 01.45
09.16 No. 2 AND function source 2 10.07 VMA 33/34
63
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
05 = MOTORISED POT.
Parameter Parameter definition Factory setting
01.09 Reference offset select ref + 01.04
01.14 Selection of references ana. input 1
06.04 Start/stop logic select Latched Run/
06.43 Origin of commands via terminals
07.06 ADI1 mode 0-10V
07.10 ADI1 input destination 01.36
07.11 ADI2 mode Digital input
07.14 ADI2 input destination 09.26
07.15 ADIO3 mode 0-10V output
07.16 ADIO3 input or output scaling 1.0
07.17 ADIO3 input or output invert no
07.18 ADIO3 input destination/output source 10.90
08.10 Drive enable mode select lock
08.11 Digital input or output DI01 invert yes
08.12 Digital input DI2 invert no
08.13 Digital input DI3 invert no
08.14 Digital input DI4 invert no
08.21 DIO1 input destination 10.61
08.22 DI2 input destination 06.30
08.23 DI3 input destination 06.32
08.24 DI4 input destination 09.27
08.31 Selection of terminal DIO1 as input or output input
09.25 Faster/slower reference destination 01.04 VMA 33/34
64
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
APPENDIX
0.36 = ON CONTACT (ESFR OPTION ENABLED) OR ON RELAY OR ANY ASSIGNMENT using parameter 12.41.
en
36 BRAKE CONTROL R-W DISABLED DISABLED; ON CONTACT
(Address menu in manual reference 3997: 12.41)
37 BRAKE RELEASE CURRENT R-W 10.0% 0 to 200.0%
THRESHOLD (Address menu in manual reference 3997: 12.42)
38 BRAKE APPLY CURRENT R-W 10.0% 0 to 200.0%
THRESHOLD (Address menu in manual reference 3997: 12.43)
39 BRAKE RELEASE HZ R-W 1.0 Hz 0 to 20.0 Hz
THRESHOLD (Address menu in manual reference 3997: 12.44)
40 BRAKE APPLY HZ R-W 2.0 Hz 0 to 20.0 Hz
THRESHOLD (Address menu in manual reference 3997: 12.45)
41 MAGNETISATION TIME DELAY R-W 0.1 s 0 to 25.0 s
(Address menu in manual reference 3997: 12.46)
42 RAMP UNLOCK TIME DELAY R-W 0.1 s 0 to 25.0 s
(Address menu in manual reference 3997: 12.47)
IMPORTANT NOTE
In VMA 31/32, when 36 = ON CONTACT, the assignment of terminal DI01 is automatically enabled for brake control.
The parameters concerning terminal DI01 become: 33 = NO; 34 = OUTPUT; 35 = 1240.
If brake control is disabled, 36 = DISABLED. Terminal DI01 must then be reassigned to external fault management via the following
parameters: 33 = YES; 34 = INPUT; 35 = 1061, thus returning to the standard configuration.
The fault "loss of phase" is linked to the brake command. When the motor is rotating, if the motor current falls below the set point
in parameter 38 (or 12.43), the drive goes into fault mode "loss of phase".
To disconnect this control, parameter 38 (or 12.43) must be set to "0".
65
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
NOTE
66
LEROY-SOMER PARAMETER-SETTING MANUAL 3847 en - 2013.06 / i
VARMECA 30
Variable speed motors and geared motors
NOTE
en
67
Moteurs Leroy-Somer
Headquarter: Boulevard Marcellin Leroy - CS 10015
16915 ANGOULÊME Cedex 9
Limited company with capital of 65,800,512 €
RCS Angoulême 338 567 258
www.leroy-somer.com