Diagrammatic sketch
Gas stove
Pluggable terminal
Slide cover
Please slide the cover 3. For home installation should pay attention, please do not install
following the arrow direction
the detector near the gas stove, to avoid detector bake by the
stove flame, do not install in the place with large lampblack, to
avoid wrong alarm or cause the detector air intake not smooth,
which greatly affect to sensibility of the detector, please do not
fix near the ventilators, windows, doors, shower room with
much source of steam.
Test Notices
After fix well the gas leakage detector, you could give small amount
1. Please install the detector according to user manual recommended sketch
of gas which is around 5cm from the gas convention window to test
map. If not possible to meet the condition, installation person should consider
the detector alarm state by lighter non-ignition mode, when alarm the relative factors of “installation environment”,find out the best position to fix
would come with the output of networking signal, could be judge as it. To make sure detector under valid monitor range.
system networking access testing. Due to the Inherent characteristics
2.In order to low down cost of the project installation maintenance and reduce
of semiconductor detector, please do not release plenty of gas with the fault alarm due to the improper construction, the installation person should
high density to test the detector, and do not frequently or long time conduct an initial assessment of the kitchen function, distribution, setting to
testing the detector which might caused the damage of detector confirm the best position of wiring and installing before installation & wiring.
sensitive material and the great fall of the detector sensitivity, all
would result in fault alarm. The alarm density of gas is setting 3.Please do make sure to realize that the gas released from house decoration
is a damage for the detector, could not be recovery which might cause the fault
according to the criteria of GB15322.2-2003 regulated value, the
alarm or invalid. During the decoration time, we suggest user to use regular
detector would stop alarming and turn into detecting state while the environment protection material, do not take off products blister, it could
gas density is lower than alarm level. automatic deposit dust proof. Open the door and window, keep indoor
ventilation, if it is possible, you could take off the detector temporary.
Test skill
Control the lighter gas density from small to large manually, with
different mode of ignition, distance around 5cm from the gas Matters need attention
convention window (do not test it directly to the detector) to release
the gas (check and make sure the red led light will flash) slowly from 1. The product must work with correct connection and right power
thin to thick, keep it until detector alarm with red light flash, then supplier, the detector could not work normally no matter
immediately remove the lighter. The direct impact of high density what ‘s reason caused the power off,.
gas to the detector should be avoid when it is being test. 2. Please take off the blister in time after the detector keeping
work for 24 hours powering on.
Maintenance 3. The product should keep periodic maintenance according to
the user manual.
After long time use of gas detector, the gas convention window
4. The detector could not work without life time limit,our
would caused the adhesion of oil, which effect the sensitive of recommended validity life is 3 year, it should be test every
half year, and you should repair or change after find it invalid.
5. The product could not use high density(>100% LEL)gas to
test, otherwise it might reduce the sensor sensitivity, and
cause the sensor could not work normally.
6. The product could reduce the accident, but could not make
sure a hundred percent safe. For your safety, please keep
precaution and enhance safety consciousness in daily life,
besides using our products correctly.