» Generator set data sheet

Model: C80 D6 (6B)


Frequency: 60
Fuel Type: Diesel

Spec sheet: SS28-CPGK


Noise data sheet (Open/enclosed): ND60-CS550
Airflow data sheet: AF60-550
Derate data sheet (Open/enclosed): TBD
Transient data sheet: TD60-550

Standby Prime
Fuel consumption Kw (kVA) Kw (kVA)
Ratings 80 (100) 73 (91)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 1.6 2.9 4.3 6.0 1.5 2.6 3.9 5.3
L/hr 7.3 13.1 19.7 27.2 6.6 12.0 17.6 24.0

Engine Standby Rating Prime Rating


Engine manufacturer Cummins
Engine model 6BTA5.9 G6
Configuration Inline 6-Cylinder Diesel
Aspiration Turbocharged and After Cooled
Gross engine power output, kWm 132 119
BMEP at set rated load, kPa 1492 1344
Bore, mm 102
Stroke, mm 120
Rated speed, rpm 1800
Piston speed, m/s 7.2
Compression ratio 17.3:1
Lube oil capacity, L 16.4
Overspeed limit, rpm 2100
Regenerative power, kW 7.272727273
Governor type Electronic
Starting voltage 12V Volts DC

Fuel flow
Maximum fuel flow, L/hr 45
Maximum fuel inlet restriction, mm Hg 8
Maximum fuel inlet temperature (°C) 71

©2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Document no. DS382-CPGK-RevA - 27/1/2012
Air Standby Rating Prime Rating
Combustion air, m 3/min 175.00 162.00
Maximum air cleaner restriction, kPa 6

Exhaust
Exhaust gas flow at set rated load, m3/min 28.2 19.5
Exhaust gas temperature, °C 551 528
Maximum exhaust back pressure, kPa 10

Standard set-mounted radiator cooling


Ambient design, °C 49.3
Fan load, KW m 5.60992
Coolant capacity (with radiator), L 19.75
Cooling system air flow, m3/sec @ 12.7mmH2O 3.24
Total heat rejection, BTU/min 11464 10112
Maximum cooling air flow static restriction mmH2O 12.7

Weights* Open Enclosed


Unit dry weight kgs 1263 1963
Unit wet weight kgs 1574 2274
* Weights represent a set with standard features. See outline drawing for weights of other configurations

Dimensions Length Width Height


Standard open set dimensions 2268 1094 1576
Enclosed set standard dimensions 3151 1142 1714

Genset outline

Open set

Enclosed set

Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.

©2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Document no. DS382-CPGK-RevA - 27/1/2012
Alternator data
Connection 1 Temp rise °C Duty2 Alternator Voltage
Wye -3 phase 150/125 S/P UCI224G 220-240
Wye -3 phase 150/125 S/P UCI224G 380
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0

Ratings definitions
Emergency Standby Limited-Time running Prime Power (PRP) Base Load (Continuous)
Power (ESP) Power (LTP): Power (COP)

Applicable for supplying power to Applicable for supplying power to a Applicable for supplying power to Applicable for supplying power
varying electrical load for the constant electrical load for limited varying electrical load for unlimited continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running Power hours. Prime Power (PRP) is in load for unlimited hours. Continuous
reliable utility source. Emergency (LTP) is in accordance with ISO accordance with ISO 8528. Ten Power (COP) in accordance with ISO
Standby Power (ESP) is in 8528. percent overload capability is 8528, ISO 3046, AS 2789, DIN 6271
accordance with ISO 8528. Fuel available in accordance with ISO and BS 5514.
Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS
3046, AS 2789, DIN 6271 and BS 5514.
5514.

Formulas for calculating full load currents:

Three phase output Single phase output

kWx1000 kWxSingleP haseFactor x1000


Voltagex1. 73x0.8 Voltage

See your distributor for more information.


Cummins Power Generation
Manston Park, Columbus Avenue
Manston, Ramsgate
Kent CT12 5BF, UK
Telephone: +44 (0) 1843 255000
Fax: +44 (0) 1843 255902
E-Mail: cpg.uk@cummins.com
Web: www.cumminspower.com

©2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Document no. DS382-CPGK-RevA - 27/1/2012

You might also like