Hitachi Circuit Breakers

Download as pdf or txt
Download as pdf or txt
You are on page 1of 146

FAX : <63>(2) 819-7539

: Thailand
ms Group Hitachi Asia (Thailand) Co., Ltd.
3-05 Cwt Distripark, 18th Floor, Ramaland Building, 952 Rama IV Road
619097 Bangrak, Bangkok 10500

H itach i C ircuit Bre ak er s & M iniatu re Ci rc ui t B reak er s


TEL : <66>(2) 632-9292
FAX : <66>(2) 632-9299

Chi Minh City Office)


5B Ton Duc Thang
Minh City

: China
Hitachi East Asia Ltd.
Floor, 4th Floor, North Tower
World Finance Centre, Harbour City
oi Canton Road, Tsim Sha Tsui, Kowloon
Hong Kong
TEL : <852>2735-9218
FAX : <852>2375-3192

Pvt. Ltd. Hitachi China Ltd. (Beijing Office)


(10th Floor) Room 1412, Beijing Fortune Building
Marg., New Delhi, 110001 5 Dong San Huan BeiLu
371-2817, -3953, -3958 Chao Yang District, Beijing 100004
TEL : <86>(10) 6590-8851, -8852, -8853, -8854
FAX : <86>(10) 6590-8850

arta Office) Hitachi (Shanghai) Trading Co., Ltd.


.I. Jend. 18th Floor, Rui Jin Building,
karta 10220 No.205, Maoming Road(S)
Shanghai, 200030
TEL : <86>(21) 6472-1002
FAX : <86>(21) 6415-8272

a) Sdn. Bhd. Taiwan Hitachi Asia Pacific Co., Ltd.


nara IMC (Letter Box No.5) 3rd Floor, Hung Kuo Building No.167
, 50250, Kuala Lumpur Tun-Hwa North Road, Taipei (105) , Taiwan
TEL : <886>(2) 2718-3666
8758 FAX : <886>(2) 2718-8180

is subject to change without notice.

es.co.jp/english/index.htm

For further information, please contact your nearest sales representative.


Hitachi Industrial Equipment Systems Co., Ltd.
A PPLICATIONS

Hitachi Circuit Breakers and Miniature Circuit Breakers are such as conductors, motors, and starters.
designed for circuit protection of low-voltage distribution They are designed for use in switchboard, control centers,
systems. They are suitable for application as main breakers and panel boards, combination starters, and separate individual
for protection of branch and feeder circuits and connected enclosures. In these various enclosures, they are applicable to
apparatus. These breakers provide overload protection for the requirements of lighting, distribution, and other power
conductors and short-circuit protection for all circuit elements circuits.

C ONTENTS

Applications..........................................................................................................................................1

Fuse-Free Breakers
New Line-up Series (Features) ........................................................................................................................... 2
Classification and Composition ......................................................................................................................... 4
Composition in terms of Interrupting Capacity ............................................................................................... 5
Ratings and Specifications ................................................................................................................................. 6
Construction ..................................................................................................................................................... 15
Characteristics .................................................................................................................................................. 19
Caution.............................................................................................................................................................. 20
Selection ........................................................................................................................................................... 21
Accessories ........................................................................................................................................................ 25
Dimensions ....................................................................................................................................................... 39

Earth Leakage Breakers and Earth Leakage Relays


Classification and Composition ....................................................................................................................... 67
Ratings and Specifications ............................................................................................................................... 68
Construction ..................................................................................................................................................... 72
Application of Earth Leakage Relays .............................................................................................................. 75
Dimensions ....................................................................................................................................................... 76
Earth Leakage Breakers for Welders ............................................................................................................ 106

Miniature Circuit Breakers


Features........................................................................................................................................................... 108
Specifications .................................................................................................................................................. 109
Characteristic curve and Compensation curve............................................................................................. 110

Residual Circuit Breakers


Features............................................................................................................................................................111
Specifications .................................................................................................................................................. 112

Air Circuit Breakers (AKN, AKS, AKH series)


Ordering ......................................................................................................................................................... 114
Ratings ............................................................................................................................................................ 120
Dimensions ..................................................................................................................................................... 142

1
FUSE-FREE BREAKER
NEW L INE-UPS WITH FULLY INTEGRATED C ONFIGURATION,
A DVANCED P ERFORMANCE AND SIMPLIFIED OPERATION

Hitachi Global Series


Hitachi has been developing new Molded Case Circuit
Breakers and now we have just launched new type circuit
breakers and these are innovative high quality breakers,
new technology fulfills improving the performance
and new design satisfies all application requirements
and world customers.
It's a new solution of the breakers.

FEATURES

New color
of
the face

Renew the color of the face of the breakers from


black to brighter color, Light Gray, and the impression
of the distribution panels will be improved brightly
and sophisticated.

2
High
breaking
performance

Breaking performance of standard type (F series) are lcs = 100%lcu which is world level performance of
the breaking current by new solution of breaking system and new breaking system reduces thermal and
mechanical stress to distribution systems and they can be used any distribution system.

AF 60AF 100AF 250AF 400AF 600AF 800AF 1000AF 1200AF


Types F-60RB F-100KB F-250FB F-400R F-600F F-800R FX1000 FX1200
FXK125-S F-250KC FX400 FX600 FX800
FXK125-H FXK250-S
FXK250-H

Easy to install the


Easy to
accessories and
install
easy to change the
accessories
specifications

Hitachi Global series provides wide range of the


frame and the varieties of accessories for customers.
The specifications of breakers can be changed by
cassette type internal accessories. They can be
installed by users, quickly responding to changing
specifications.
Applicable type are stated in table of Ratings and
Specifications.

Dimensions are unified for the economical and standard types,


Dimensions
contributing to total cost reduction of the control panel.
are
Breaking Capacity at 230V
unified

Even height is unified in addition to the conventional


Standard type
projected area unification. This compatibility reduces
FX, FXK, RX, RXK
the total cost in mounting panels. Interrupting
capacity is also unified for the fuse-free breaker and Economical type
earth leakage breaker within the frame of the same SX, SXK, EX, EXK
rated current, enabling easy, smooth replacement.

3
C LASSIFICATION AND C OMPOSITION

Hitachi Fuse-Free Breakers are produced in the variety of types shown below. Any type can
be freely chosen according to the purposes of applications and circuit conditions, making it
possible to design an electric circuit with high economy and reliability.

Fuse-Free Breaker for General Purpose

F Series L Series S Series


Standard Breaker High Interrupting Economical
Capacity Breaker Breaker

<Fundamental> <Current Limiting> <Small>

30A – 1600A frame 50A – 800A frame 30A – 800A frame

Motor Breaker

M Series

30A – 225A frame

4
C OMPOSITION IN TERMS OF INTERRUPTING C APACITY
AC 230V — 240V
Transformer capacity 750 –
– 30 50 – 100 150 200 – 500 2000 – 3000
(kVA) 1500
Interrupting capacity
5 7.5 10 14 25 35 42 50 85 100 125 175
kA (sym)
30 S-30E F-30FB
50 S-50EB S-50SB L-50E
60 S-60RB F-60RB
100 125 S-100EB S-100S S-100SB FXK125-S FXK125-H L-100E
FXK250-S FXK250-H
225 250 S-225SB, SXK225 L-225E
Frame (AF) F-250FB F-250KC
400 SX400, S-400S FX400, F-400R L-400E
600 SX600, S-600S FX600, F-600F L-600E
SX800 FX800
800 F-800RH L-800E
S-800S F-800R
1000 – 1200 FX1000, FX1200, F-1000K, F-1200K, F-1000C, F-1200C
1600 F-1600CB, F-1600B, F-1600E

AC 380V — 440V
Transformer capacity
– 50 75 – 100 200 – 500 750 – 1000 1500 – 2000 2500 – 3500
(kVA)
Interrupting capacity
1.5 2.5 5 7.5 10 15 18 22 25 30 35 50 85 125 175
kA (sym)
30 S-30E F-30FB
50 S-50EB S-50SB L-50E
60 S-60RB F-60RB
100 125 S-100S, S-100SB FXK125-S FXK125-H L-100E
FXK250-S FXK250-H
Frame (AF) 225 250 S-225SB, SXK225
F-250FB F-250KC
L-225E

SX400 FX400
400 L-400E
S-400S F-400R
SX600 FX600
600 L-600E
S-600S F-600F
FX800
800 SX800, S-800S F-800RH L-800E
F-800R
1000 – 1200 FX1000, FX1200, F-1000K, F-1200K, F-1000C, F-1200C
1600 F-1600CB, F-1600B, F-1600E

F Series

S Series

5
R ATINGS AND SPECIFICATIONS
Table 1 F series
Type F-30FB F-60RB F-60R F-100S FXK125-S FXK125-H F-100KB

Appearance

Number of poles 2 3 2 3 4 4 2 (*1) 3 2 (*1) 3 4

Rated Current (A) 3 5 10 15 20 30 15 20 30 50 15 20 30 40 50 15 20 30 40 50 15 20 30 40


(Base ambient temperature 40ºC) 15 20 30 40 50 60 60 75 100 63 75 100 125 63 75 100 125 50 60 75 100

Rated Insulation Voltage Ui (V) 690 690 690 690 690


Rated Impulse withstand Voltage Uimp (kV) 6 6 8 8 8
690V — — — — — —
440V 2.5 / 1 10 / 10 10 / 5 30 / 30 50 / 50
415V 2.5 / 1 10 / 10 10 / 5 30 / 30 50 / 50
Rated AC 400V 2.5 / 1 10 / 10 10 / 5 30 / 30 50 / 50
IEC 60947-2
Breaking 380V 2.5 / 1 10 / 10 10 / 5 30 / 30 50 / 50
Capacity (kA) (Icu/Ics)
240V 7.5 / 2 25 / 25 35 / 18 50 / 50 100 / 100 85 / 85
230V 7.5 / 2 25 / 25 35 / 18 50 / 50 100 / 100 85 / 85
250V 2.5 / 1 — 5/2 — — — 25 / 13 — 40 / 20 — —
DC
125V 5/2 — 7.5 / 2 — — — 25 / 13 — 40 / 20 — —
a d
c a 52 75 52 75 100 120 90 90 120
b 130 130 150 150 150
Dimensions (mm)
c 60 60 60 68 68 86
b

d 84 84 85 94 94 106
Net Weight (kg) 0.48 0.6 0.53 0.74 0.96 1.3 1.4 1.4 1.4 1.4 2.3
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal
Phase Separator for Line Side ○ ● (*2) ● ● (*2) ● (*2)
Alarm Switch AL ○ ○ ○ ○ (*3) ○ (*3) ○
Auxiliary Switch AUX ○ ○ ○ ○ (*3) ○ (*3) ○
Interior Shunt Trip SHT ○ ○ ○ ○ (*3) ○ (*3) ○
Accessories Undervoltage Trip UVT — — ○ — — ○
TB ○ ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○
STB-3H STB-2S (Up to 50A) STB-2S (Up to 50A) STB-3J
Rear-connecting STB STB-2M STB-2M STB-1B
(Up to 50A : STB-2D) BSD-3S (60A or more) BSD-3S (60A or more) (Up to 50A : STB-2)
Stud
BSD — — — —
Flush Mounting Base GKW(STB) ○ ○ ○ — — ○
Assembly GK GKW(BSD) — — — ○ (Up to 50A) ○ (Up to 50A) —
Plug-in Mounting
PK ○ ○ ○ ○ (60A or more) ○ (60A or more) ○
Base Assembly
Drawout Assembly PDK — — — — — —
Mechanical Interlock MIW MIW-2E MIW-2E MIW-1C MIW-2C MIW-3H MIW-3H MIW-3D
MMK-S — — — ○ ○ ○
Motor-operating
Exterior MMK-C — — — — — —
Mechanism
Accessories MMK — — — — — —
Lock Cover LC LC-2E LC-2E LC-1B LC-2C ○ ○ LC-2C
Handle Lock HL ○ ○ ○ ○ ○ ○
HA HA-108 HA-108 HA-107 HA-104 — — HA-106
Handle Operating
Mechanism HM- HM-
HM — — HM-57 — HM-S13 HM-S13 HM-S11
S12 S12
TMC TMC-1 TMC-1 TMC-2C TMC-2C TMC-2C TMC-3C
Front
Terminal Short Type TMC-1S TMC-1S — — — — —
Type
Cover Long Type TMC-2D TMC-2D — — — — —
Rear Type BTC BTC-1 BTC-1 BTC-2C BTC-2C BTC-2C BTC-3C
IEC Rail 35 mm ○ ○ — — — — —
Automatic Tripping Device Full Magnetic Full Magnetic Full Magnetic Thermal-Magnetic Thermal-Magnetic Full Magnetic
Trip Button ● ● ● ● ●

Attention
1. ● : Standard ○ : Option
2. 2-pole types marked with (*1) are supplied in 3-pole type.
3. Please state "For DC" in case of DC use. Especially, state please state kind of the power supply in case of from 30 to 100AF.
4. Flush Mounting Base Assembly, GKW are standard in case of up to 250AF and FX400.
5. Please state that number of poles of breakers when order MIW.
6. Installation of phase separators is required in case of types marked (*2).
7. Tripping system of F-1000K and F-1200K are induction heat system, please state frequency when ordering.
8. For DC use, the tripping character is only instantaneous trip in case of F-1000K and F-1200K.
9. The accessories marked (*3) can be installed by customers.

6
FXK250-S F-250FB FXK250-H F-250KC F-400R FX400 F-600F FX600

2 (*1) 3 4 2 (*1) 3 4 2 (*1) 3 4 2 (*1) 3 2 (*1) 3 4 3


200 / 225 / 250 300 / 350 / 400
125 150 175 125 150 175 250 300
300 / 350 / 400 500 600 500 / 600
200 225 250 200 225 250 300 400
adjustable adjustable
690 690 690 690 690 690
8 8 8 8 8 8
— — — — — — —
30 / 30 50 / 50 50 / 50 50 / 50 50 / 50 50 / 50
30 / 30 50 / 50 50 / 50 50 / 50 50 / 50 50 / 50
30 / 30 50 / 50 50 / 50 50 / 50 50 / 50 50 / 50
30 / 30 50 / 50 50 / 50 50 / 50 50 / 50 50 / 50
50 / 50 85 / 85 100 / 100 85 / 85 100 / 100 100 / 100 100 / 100 100 / 100
50 / 50 85 / 85 100 / 100 85 / 85 100 / 100 100 / 100 100 / 100 100 / 100
25 / 13 — — 40 / 20 — — 40 / 40 — — — 40 / 40 — — —
25 / 13 — — 40 / 20 — — 40 / 40 — — — 40 / 40 — — —
105 140 105 140 140 185 140 210 280 210
165 165 257 257 274 274
68 103 68 103 103 103 103 103
95 127 95 127 133 133 141 141
1.6 3.1 1.6 3.1 5.3 6.1 8.2 5.1 5.9 10 13 9.7
Front Terminal Front Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
○ (*3) ○ ○ (*3) ○ ○ ○ (*3) ○ ○ (*3)
○ (*3) ○ ○ (*3) ○ ○ ○ (*3) ○ ○ (*3)
○ (*3) ○ ○ (*3) ○ ○ ○ (*3) ○ ○ (*3)
— — ○ ○ ○ ○
○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○
— — — — — —

○ ○ ○ ○ ○ ○
— — — — —
○ ○ ○ (GK) ○ ○ (GK) ○ (GK)
○ ○ ○ ○ ○ ○
— — — — — —
MIW-4M MIW-4H MIW-4M MIW-4H MIW-5D MIW-5F MIW-5 MIW-5G
— — — — — —
— — ○ ○ ○ ○
— — — — — —
LC-4J LC-4H LC-4J LC-4H — — — —
HL-4J ○ HL-4J ○ HL-5 HL-5 HL-6 HL-6
HA-210 HA-206 HA-210 HA-206 HA-405 HA-406 HA-402 HA-402

HM-S25 HM-S21 HM-S25 HM-S21 HM-405 HM-406 HM-402 HM-407

TMC-4J TMC-4H TMC-4J TMC-4H TMC-5B TMC-5B TMC-5D TMC-5D


TMC-4JS — TMC-4JS — — — — —
— — — — — — — —
BTC-4J — BTC-4J — BTC-5B BTC-5B — —
— — — — — —
Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Electronic Relay Thermal-Magnetic Electronic Relay
● ● ● ● ● ●

7
Table 1 F series
Type F-800R FX800 F-800RH F-1000K F-1000C

Appearance

Number of poles 3 4 3 3 4 3 4 3 4
400 / 450 / 500 500 / 600 / 700
Rated Current (A)
700 800 600 / 700 / 800 700 800 1000 800 / 900 / 1000
(Base ambient temperature 40ºC)
adjustable adjustable
Rated Insulation Voltage Ui (V) 690 690 690 690 690
Rated Impulse withstand Voltage Uimp (kV) 8 8 8 8 8
690V — — — — —
440V 50 / 50 50 / 50 85 / 43 85 / 22 85 / 22
415V 50 / 50 50 / 50 85 / 43 85 / 22 85 / 22
Rated AC 400V 50 / 50 50 / 50 85 / 43 85 / 22 85 / 22
IEC 60947-2
Breaking 380V 50 / 50 50 / 50 85 / 43 85 / 22 85 / 22
Capacity (kA) (Icu/Ics)
240V 100 / 100 100 / 100 125 / 63 125 / 32 125 / 32
230V 100 / 100 100 / 100 125 / 63 125 / 32 125 / 32
250V 40 / 40 — — 40 / 40 — 40 / 10 — —
DC
125V 40 / 40 — — 40 / 40 — 40 / 10 — —
a d
c a 210 280 210 210 280 210 280 210 280
b 274 274 274 410 410
Dimensions (mm)
c 103 103 103 150 150
b

d 141 141 141 190 190


Net Weight (kg) 10.5 13.5 11 10.5 13.5 26 33 26 33
Standard Connection Type Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
Phase Separator for Line Side ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
Alarm Switch AL ○ ○ (*3) ○ ○ ○
Auxiliary Switch AUX ○ ○ (*3) ○ ○ ○
Interior Shunt Trip SHT ○ ○ (*3) ○ ○ ○
Accessories Undervoltage Trip UVT ○ ○ ○ ○ ○
TB ○ ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○
Rear-connecting STB — — — — —
Stud BSD ○ ○ ○ ○ ○
Flush Mounting Base GKW(STB) — — — — —
Assembly GK GKW(BSD) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK)
Plug-in Mounting
PK ○ ○ ○ ○ ○
Base Assembly
Drawout Assembly PDK — — — — —
Mechanical Interlock MIW MIW-5 MIW-5G MIW-5 MIW-8 MIW-8
MMK-S — — — — —
Motor-operating
Exterior MMK-C ○ ○ ○ ○ ○
Mechanism
Accessories MMK — — — — —
Lock Cover LC — — — — —
Handle Lock HL HL-6 HL-6 HL-6 ○ ○
Handle Operating HA HA-402 HA-402 HA-402 HA-801 HA-801
Mechanism HM HM-402 HM-407 HM-402 — —
TMC TMC-5D TMC-5D TMC-5D TMC-6 TMC-6
Front
Terminal Short Type — — — — —
Type
Cover Long Type — — — — —
Rear Type BTC — — — —
IEC Rail 35 mm — — — — —
Automatic Tripping Device Thermal-Magnetic Electronic Relay Thermal-Magnetic Thermal-Magnetic Electronic Relay
Trip Button ● ● ● ● ●

Attention
1. ● : Standard ○ : Option
2. 2-pole types marked with (*1) are supplied in 3-pole type.
3. Please state "For DC" in case of DC use. Especially, state please state kind of the power supply in case of from 30 to 100AF.
4. Flush Mounting Base Assembly, GKW are standard in case of up to 250AF and FX400.
5. Please state that number of poles of breakers when order MIW.
6. Installation of phase separators is required in case of types marked (*2).
7. Tripping system of F-1000K and F-1200K are induction heat system, please state frequency when ordering.
8. For DC use, the tripping character is only instantaneous trip in case of F-1000K and F-1200K.
9. The accessories marked (*3) can be installed by customers.

8
R ATINGS AND S PECIFICATIONS

FX1000 F-1200K F-1200C FX1200 F-1600CB F-1600B F-1600E

3 3 4 3 4 3 3 4 3 4 3 4
500 / 600 / 700 600 / 700 / 800 600 / 700 / 800 800 / 900 / 1000 800 / 900 / 1000
1000 1200
800 / 900 / 1000 1200 1000 / 1200 1000 / 1200 1200 / 1400 / 1600 1200 / 1400 / 1600
1400 1600
adjustable adjustable adjustable adjustable adjustable
690 690 690 690 690 690 690
8 8 8 8 8 8 8
— — — — — — 45 / 34
85 / 85 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 85 / 64
85 / 85 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 85 / 64
85 / 85 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 100 / 75
85 / 85 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 100 / 75
125 / 125 125 / 32 125 / 32 125 / 125 125 / 32 125 / 32 125 / 94
125 / 125 125 / 32 125 / 32 125 / 125 125 / 32 125 / 32 125 / 94
— 40 / 10 — — — — 40 / 10 — —
— 40 / 10 — — — — 40 / 10 — —
210 210 280 210 280 210 210 280 210 280 210 280
410 410 410 410 410 410 370
150 150 150 150 150 150 140
190 190 190 190 190 190 191
26 26 33 26 33 26 37 49 37 49 27 36
Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) —
○ (*3) ○ ○ ○ (*3) ○ ○ ○
○ (*3) ○ ○ ○ (*3) ○ ○ ○
○ (*3) ○ ○ ○ (*3) ○ ○ ○
○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ —
— — — — — — —
○ ○ ○ ○ ○ ○ ○
— — — — — — —
○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK)
○ ○ ○ ○ — — —

— — — — — — ○
MIW-8 MIW-8 MIW-8 MIW-8 MIW-8D MIW-8D ○
— — — — — — —
○ ○ ○ ○ ○ ○ —
— — — — — — ○
— — — — — — ○
○ ○ ○ ○ ○ ○ ○
HA-801 HA-801 HA-801 HA-801 HA-801 HA-801 ○
— — — — — — —
TMC-6B TMC-6 TMC-6 TMC-6B — — —
— — — — — — —
— — — — — — —
— — — — — — —
— — — — — — —
Electronic Relay Thermal-Magnetic Electronic Relay Electronic Relay Electronic Relay Magnetic Electronic Relay
● ● ● ● ● ● ●

9
Table 2 S series
Type S-30S S-30E S-50E S-50EB S-50SB S-60RB S-100EB

Appearance

Number of poles 2 3 2 3 2 3 2 3 2 3 2 3 2 3

Rated Current (A) 3 5 10 3 5 10 5 10 15 20 5 10 15 20 5 10 15 20 5 10 15 20


60 75 100
(Base ambient temperature 40ºC) 15 20 30 15 20 30 30 40 50 30 40 50 30 50 30 50 60

Rated Insulation Voltage Ui (V) 500 500 500 500 690 690 250
Rated Impulse withstand Voltage Uimp (kV) — 4 — 4 6 6 6
690V — — — — — — —
440V — — — — 2.5 / 1 5/2 —
415V — 1.5 / 1 — 1.5 / 1 2.5 / 1 5/2 —
Rated AC 400V 1.5 / 1 1.5 / 1 1.5 / 1 1.5 / 1 2.5 / 1 5/2 —
IEC 60947-2
Breaking 380V 1.5 / 1 — 1.5 / 1 — 2.5 / 1 5/2 —
Capacity (kA) (Icu/Ics)
240V 2.3 / 1.3 — 2.3 / 1.3 — 7.5 / 2 10 / 3 10 / 3
230V 2.5 / 1.3 5/2 2.3 / 1.3 5/2 7.5 / 2 10 / 3 10 / 3
250V — — — — 2.5 / 1 — 2.5 / 1 — 2.5 / 1 —
DC
125V — — — — 5/2 — 5/2 — 5/2 —
a d
c a 50 75 50 75 50 75 50 75 52 75 52 75 52 75
b 95 96 96 96 130 130 130
Dimensions (mm)
c 60 60 60 60 60 60 60
b

d 79 76 79 76 84 84 84
Net Weight (kg) 0.32 0.47 0.25 0.37 0.32 0.47 0.25 0.37 0.48 0.6 0.5 0.7 0.5 0.7
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal
Phase Separator for Line Side (*2) — — — — ○ ○ ○
Alarm Switch AL — ○ — ○ ○ ○ ○
Auxiliary Switch AUX — ○ — ○ ○ ○ ○
Interior Shunt Trip SHT — ○ — ○ ○ ○ ○
Accessories Undervoltage Trip UVT — — — — — — —
TB — — — — ○ ○ ○
Terminal Block
TB2 — ○ — ○ ○ ○ ○
STB-3K STB-3K
Rear-connecting STB — — — — STB-2M
(Up to 50A :STB-2M) (Up to 50A :STB-2M)
Stud
BSD — — — — — — —
Flush Mounting Base GKW(STB) — — — — ○ ○ ○
Assembly GK GKW(BSD) — — — — — — —
Plug-in Mounting
PK — — — — ○ ○ ○
Base Assembly
Drawout Assembly PDK — — — — — — —
Mechanical Interlock MIW — — — — MIW-2E MIW-2E MIW-2E
MMK-S — — — — — — —
Exterior Motor-operating
MMK-C — — — — — — —
Accessories Mechanism
MMK — — — — — — —
Lock Cover LC LC-0B LC-03 LC-0B LC-03 LC-2G LC-2G LC-2G
Handle Lock HL — — — — HL-2G HL-2G HL-2G
Handle Operating HA — — — — HA-108 HA-108 HA-108
Mechanism HM — — — — HM-S12 — HM-S12 — HM-S12
TMC TMC-0C TMC-0A TMC-0G TMC-0C TMC-0A TMC-0G TMC-1 TMC-1 TMC-1
Front
Terminal Short Type — — — — TMC-1S TMC-1S TMC-1S
Type
Cover Long Type — — — — TMC-2D TMC-2D TMC-2D
Rear Type BTC — — — — BTC-1 BTC-1 BTC-1
IEC Rail 35 mm ● ● ● ● ○ ○ ○
Automatic Tripping Device Full Magnetic Full Magnetic Full Magnetic Full Magnetic Full Magnetic Full Magnetic Full Magnetic
Trip Button ● — ● — ● ● ●

Attention
1. ● : Standard ○ : Option
2. 2-pole types marked with (*1) are supplied in 3-pole type.
3. Please state "For DC" in case of DC use . Especially, state please state kind of the power supply in case of from 30AF to 100AF.
4. Please state that number of poles of breakers when order MIW.
5. Installation of phase separators is required in case of types marked (*2).
6. The accessories marked (*3) can be installed by customers.

10
R ATINGS AND S PECIFICATIONS

S-100SB S-100S S-225SB SXK225 S-400S SX400 S-600S SX600 S-800S SX800

2 3 2 3 2 (*1) 3 2 (*1) 3 2 (*1) 3 2 (*1) 3 2 (*1) 3 3 3 3


200 / 225 / 250 300 / 350 / 400 400 / 450 / 500
125 150 175 125 150 175 250 300
60 75 100 60 75 100 300 / 350 / 400 500 600 500 / 600 700 800 600 / 700 / 800
200 225 200 225 350 400
adjustable adjustable adjustable
690 690 690 690 690 690 690 690 690 690
6 6 6 6 8 8 8 8 8 8
— — — — — — — — — —
10 / 3 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18
10 / 3 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18
10 / 3 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18
10 / 3 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18 36 / 18
35 / 9 25 / 7 35 / 18 35 / 18 50 / 25 50 / 25 50 / 25 50 / 25 85 / 43 85 / 43
35 / 9 25 / 7 35 / 18 35 / 18 50 / 25 50 / 25 50 / 25 50 / 25 85 / 43 85 / 43
5/2 — 5/2 — 10 / 5 — 10 / 5 — 25 / 13 — — — 40 / 20 — — — 40 / 20 —
7.5 / 2 — 7.5 / 2 — 15 / 8 — 15 / 8 — 25 / 13 — — — 40 / 20 — — — 40 / 20 —
52 75 65 90 105 105 140 140 210 210 210 210
130 150 165 165 257 257 274 274 274 274
60 60 60 68 103 103 103 103 103 103
84 85 85 95 133 133 141 141 141 141
0.53 0.74 0.7 1 1.6 1.6 5.3 6.1 5.1 5.9 10 9.7 10.5 11
Front Terminal Front Terminal Front Terminal Front Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
● (*2) ○ ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
○ ○ ○ ○ (*3) ○ ○ (*3) ○ ○ (*3) ○ ○ (*3)
○ ○ ○ ○ (*3) ○ ○ (*3) ○ ○ (*3) ○ ○ (*3)
○ ○ ○ ○ (*3) ○ ○ (*3) ○ ○ (*3) ○ ○ (*3)
— — ○ — — ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○
STB-3K STB-3H
— — — — — — — —
(Up to 50A :STB-2M) (Up to 50A : STB-2D)
— — ○ ○ ○ ○ ○ ○ ○ ○
○ ○ — — — — — — — —
— — ○ ○ ○ (GK) ○ ○ (GK) ○ (GK) ○ (GK) ○ (GK)
○ ○ — — ○ ○ ○ ○ ○ ○
— — — — — — — — — —
MIW-2E MIW-2C MIW-4F MIW-4L MIW-5D MIW-5F MIW-5 MIW-5G MIW-5 MIW-5G
— — ○ — — — — — — —
— — — — ○ ○ ○ ○ ○ ○
— — — — — — — — — —
LC-2G LC-2C LC-4E LC-2F — — — — — —
HL-2G ○ HL-4E HL-2F HL-5 HL-5 HL-6 HL-6 HL-6 HL-6
HA-108 HA-104 HA-207 HA-209 HA-405 HA-406 HA-402 HA-402 HA-402 HA-402
— HM-S12 — HM-S22 HM-S23 HM-405 HM-406 HM-402 HM-407 HM-402 HM-407
TMC-1 TMC-2C TMC-4K TMC-4J TMC-5B TMC-5B TMC-5D TMC-5D TMC-5D TMC-5D
TMC-1S — TMC-4JS TMC-4JS — — — — — —
TMC-2D — — — — — — — — —
BTC-1 BTC-2C BTC-4G BTC-4J BTC-5B BTC-5B — — — —
○ — — — — — — — — —
Full Magnetic Full Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Electronic Relay Thermal-Magnetic Electronic Relay Thermal-Magnetic Electronic Relay
● ● ● ● ● ● ● ● ● ●

11
Table 3 L series
Type L-50E L-100E L-225E L-400E L-600E L-800E

Appearance

Number of poles 3 4 3 4 3 4 3 4 3 4 3 4
Rated Current (A) 5 10 15 15 20 30 125 150 175 250 300
500 600 700 800
(Base ambient temperature 40ºC) 20 30 50 50 60 75 100 200 225 350 400
Rated Insulation Voltage Ui (V) 690 690 690 690 690 690
Rated Impulse withstand Voltage Uimp (kV) 8 8 8 8 8 8
690V — — — — — —
440V 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
415V 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
Rated AC 400V 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
IEC 60947-2
Breaking 380V 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
Capacity (kA) (Icu/Ics)
240V 175 / 88 175 / 88 175 / 88 175 / 88 175 / 88 175 / 88
230V 175 / 88 175 / 88 175 / 88 175 / 88 175 / 88 175 / 88
250V — — — — — —
DC
125V — — — — — —
a d
c
a 90 120 90 120 140 185 140 185 210 280 210 280
b 150 150 257 257 274 274
Dimensions (mm)
c 103 103 103 103 103 103
b

d 123 123 133 133 141 141


Net Weight (kg) 2.0 2.5 2.0 2.5 5.2 7.0 6.1 8.2 10.0 13.0 10.5 13.5
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
Phase Separator for Line Side (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
Alarm Switch AL ○ ○ ○ ○ ○ ○
Auxiliary Switch AUX ○ ○ ○ ○ ○ ○
Interior Shunt Trip SHT ○ ○ ○ ○ ○ ○
Accessories Undervoltage Trip UVT ○ ○ ○ ○ ○ ○
TB ○ ○ ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○ ○
Rear-connecting STB ○ ○ — — — —
Stud BSD — — ○ ○ ○ ○
Flush Mounting Base GKW(STB) ○ ○ — — — —
Assembly GK GKW(BSD) — — ○ (GK) ○ (GK) ○ (GK) ○ (GK)
Plug-in Mounting
PK ○ ○ ○ ○ ○ ○
Base Assembly
Drawout Assembly PDK — — — — — —
Mechanical Interlock MIW MIW-3E MIW-3E MIW-5D MIW-5D MIW-5 MIW-5
MMK-S ○ ○ — — — —
Motor-operating
Exterior MMK-C — — ○ ○ ○ ○
Mechanism
Accessories MMK — — — — — —
Lock Cover LC LC-2C LC-2C — — — —
Handle Lock HL ○ ○ HL-5 HL-5 HL-6 HL-6
Handle Operating HA HA-106 HA-106 HA-405 HA-405 HA-402 HA-402
Mechanism HM HM-S11 HM-S11 HM-405 HM-405 HM-402 HM-402
TMC TMC-3C TMC-3C TMC-5B TMC-5B TMC-5D TMC-5D
Front
Terminal Short Type — — — — — —
Type
Cover Long Type — — — — — —
Rear Type BTC BTC-3C BTC-3C BTC-5B — BTC-5B — — —
IEC Rail 35 mm — — — — — —
Automatic Tripping Device Full Magnetic Full Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic
Trip Button ● ● ● ● ● ●

Attention
1. ● : Standard ○ : Option
2. Please state "For DC" in case of DC use. Especially, state please state kind of the power supply in case of from 30 to 100AF.
3. Please state that number of poles of breakers when order MIW.
4. Installation of phase separators is required in case of types marked (*2).
5. The accessories marked (*3) can be installed by customers.

12
R ATINGS AND S PECIFICATIONS

Table 4 M series
Type MS-30E MS-50EB MS-50SB MS-100SB MFXK100-S MS-225SB MSXK225 MFXK225-S

Appearance

Number of poles 3 3 3 3 3 3 3 3
0.7 1.4 2.3
0.8 1.2 1.4 2
2.6 4.2 5.6
Rated Current (A) 2.5 4 5 6.3 10 12 16 25 125 150 125 150 125 150
7.4 9 10 14 60 75 90 60 75 90
(Base ambient temperature 40ºC) 7.1 8 10 12 32 40 45 175 225 175 225 175 225
16 25 33 40
16 25 32
45
Rated Insulation Voltage Ui (V) 500 500 690 690 690 690 690 690
Rated Impulse withstand Voltage Uimp (kV) 4 4 6 6 8 6 6 8
690V — — — — — — — —
500V — — 1.5 / 1 2.5 / 1 10 / 10 5/3 5/3 10 / 5
440V — — 2.5 / 1 10 / 3 30 / 30 15 / 8 15 / 8 30 / 15
Rated IEC 60947-2 415V 1.5 / 1 1.5 / 1 2.5 / 1 10 / 3 30 / 30 15 / 8 15 / 8 30 / 15
Breaking AC
Capacity (kA) (Icu/Ics) 400V 1.5 / 1 1.5 / 1 2.5 / 1 10 / 3 30 / 30 15 / 8 15 / 8 30 / 15
380V — — 2.5 / 1 10 / 3 30 / 30 15 / 8 15 / 8 30 / 15
240V — — 7.5 / 2 35 / 9 50 / 50 35 / 18 35 / 18 50 / 25
230V 5/2 5/2 7.5 / 2 35 / 9 50 / 50 35 / 18 35 / 18 50 / 25
a d
c
a 75 75 75 75 90 105 105 105
b 96 96 130 130 150 165 165 165
Dimensions (mm)
c 60 60 60 60 68 60 68 68
b

d 76 76 84 84 94 85 95 95
Net Weight (kg) 0.37 0.37 0.6 0.74 1.6 1.6 1.6 1.6
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal
Phase Separator for Line Side (*2) — — ○ ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
Alarm Switch AL ○ ○ ○ ○ ○ ○ ○ (*3) ○ (*3)
Auxiliary Switch AUX ○ ○ ○ ○ ○ ○ ○ (*3) ○ (*3)
Interior Shunt Trip SHT ○ ○ ○ ○ ○ ○ ○ (*3) ○ (*3)
Accessories Undervoltage Trip UVT — — — — — — — —
TB — — ○ ○ ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○ ○ ○ ○
Rear-connecting STB — — STB-2M STB-3K — — — —
Stud BSD — — — — ○ ○ ○
Flush Mounting Base GKW(STB) — — ○ ○ — — — —
Assembly GK GKW(BSD) — — — — ○ ○ ○
Plug-in Mounting
PK — — ○ ○ ○ — — ○
Base Assembly
Drawout Assembly PDK — — — — — — — —
Mechanical Interlock MIW — — MIW-2E MIW-2E MIW-4F MIW-4L MIW-4M
MMK-S — — — — ○ ○ — —
Motor-operating
Exterior MMK-C — — — — — — — —
Mechanism
Accessories MMK — — — — — — — —
Lock Cover LC LC-03 LC-03 LC-2G LC-2G ○ LC-4E LC-2F LC-4J
Handle Lock HL — — HL-2G HL-2G ○ HL-4E HL-2F HL-4J
Handle Operating HA — — HA-108 HA-108 — HA-207 HA-209 HA-210
Mechanism HM — — HM-S12 HM-S12 HM-S13 HM-S22 HM-S23 HM-S25
TMC TMC-0G TMC-0G TMC-1 TMC-1 TMC-2C TMC-4K TMC-4J TMC-4J
Front
Terminal Short Type — — TMC-1S TMC-1S — TMC-4JS TMC-4JS TMC-4JS
Type
Cover Long Type — — TMC-2D TMC-2D — — — —
Rear Type BTC — — BTC-1 BTC-1 BTC-2C BTC-4G BTC-4J BTC-4J
IEC Rail 35 mm ● ● ○ ○ — — — —
Automatic Tripping Device Full Magnetic Full Magnetic Full Magnetic Full Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic
Trip Button — — ● ● ● ● ● ●

Attention
1. ● : Standard ○ : Option
2. Please state that number of poles of breakers when order MIW.
3. Installation of phase separators is required in case of types marked (*2).
4. The accessories marked (*3) can be installed by customers.

13
Table 5 Selecting Table of a Motor Breaker for 3-phase Induction Motor

200 – 220V AC 400 – 440V AC


Motor Breaker Motor Breaker Motor Breaker Motor Breaker
Motor Motor Motor Motor
Rated Rated Rated Rated
Capacity Capacity Capacity Capacity
Current Type Current Type Current Type Current Type
(kW) (kW) (kW) (kW)
(A) (A) (A) (A)
MS-50EB, 0.2 0.8 11 25 MS-30E,
0.2 1.4 11 45
MS-50SB 0.4 1.4 15 32 MS-50EB
0.4 2.5 15 60 0.75 2.5 18.5 40
MS-100SB, MS-50SB
0.75 4 18.5 75 1.5 4 22 45
MFXK100-S
1.5 8 MS-30E 22 90 2.2 6.3 MS-30E 30 60
MS-100SB,
2.2 10 30 (125)* 3.7 10 37 75
MS-225SB, MFXK100-S
3.7 16 37 (150)* 5.5 16 45 90
MFXK225-S
5.5 25 MS-225SB,
7.5 16 50 (125)*
7.5 32 MFXK225-S
Note:
1. Starting conditions are set within 3 seconds at 500% (2 seconds at 600%) of full load current for types MS-30E, MS-50EB, MS-50SB and within 8 seconds at 500% (5
seconds at 600%) of full load current for other types.
2. Specify the rated current since the figures with asterisks are the mere reference current.

● Overcurrent Tripping Characteristics

MS-30E, MS-50EB MS-50SB MFXK100-S


Hr.

Hr.
Hr.

Max. value of 31 to 50A


Min.

Min.
Min.

Max. Max. value of less than 30A


Max. value
Tripping Time

Tripping Time

Tripping Time

Min.
Max.
Min. value interrupting
Sec.

time
Sec.

Min. value
Sec.

MS-100SB MS-225SB MFXK225-S


Hr.

Hr.

Hr.

Max. value Cold start max. value Cold start max. value
Min.

Min.

Min.

Hot start Hot start


max. value max. value
Tripping Time

Tripping Time

Tripping Time

Min. value Min. value

Min.
value
Sec.

Sec.
Sec.

Max. Max.
interrupting interrupting
time time

14
C ONSTRUCTION

Hitachi Fuse-Free Breaker is comprised a switching mechanism, arc The arc is thus confined, divided and extinguished.
extinguishing devices, and a tripping unit contained in a compact
molded case. ■ Tripping Unit
The tripping unit of the Fuse-Free Breaker is produced in two types:
■ Switching Mechanism a thermal-magnetic type and a full-magnetic type. The tripping unit is
The switching mechanism is a quick-make/quick-break type utilizing a provided for each pole of the breaker, and if any one pole operates, all
trip-free toggle mechanism. of the poles open the circuit simultaneously.

■ Arc Extinguishing Device ■ Positive Indication


The series of grid plates is mounted in parallel between supports The handle position gives positive indication of whether the breaker is
of insulating material. The slots in the steel plates extend directly ON (top), OFF (down) or tripped (midway).
over the contacts and draw the arc from moving contact up into the
divided chamber.

Fig. 1 Thermal Magnetic Type

15
Fig. 2 Full magnetic Type

Handle

Molded cover

Line terminal

Load terminal

Full magnetic type


Molded case tripping mechanism
Fixed contact Moving contact

Principle (How the tripping mechanism operates)

Fig. 3 Normality Fig. 4 Time-Delay Action (1)

Magnet coil Yoke

Movable
iorn core
Armature

Cylinder Pole piece


(Brass tube) Spring silicon liquid oil

This figure shows that the movable iron core and armature When overcurrent flows through the magnet coil, only the
do not move at less than rated current of the breaker. movable iron core moves for the pole piece, overcoming
viscosity of the silicon liquid oil.

Fig. 5 Time-Delay Action (2) Fig. 6 Instantaneous Action

The armature is pulled at the pole piece, overcoming the When a large current flows through the magnet coil, take
core spring by increasing of the flux, and the armature short circuit for instance, armature is pulled at pole piece
operates the tripping mechanism of the breaker. instantly without moving iron core, and it operates the
tripping mechanism of the breaker.

16
Construction of Current-Limiting Type Breakers (L series)

L -S er ie s bre ak ers r api dl y interrupt


Handle Quick-make, quick-break,
Moving contact high faulty current by electromagnetic
trip-free mechanism repulsing mechanism.
Arc extinguishing
Tripping unit
device Available Current

Current
Let thru current by
standard FFB
Let thru current by
current-limiting type FFB

Line
terminal Load Time
terminal

About 4 to 8ms
About 10 to 20ms

Current limiting Arc extinguishing


contact device

Fig. 7 Construction of L-100E

When a current flows through a conductor in one direction while another current
flows through a conductor in the opposite direction (as shown in the figure on the
left), an electromagnetic repulsing force act between the conductors. The current-
limiting type breaker utilizes this force to complete high-speed current interruption
within an extremely short period of time.

Fig. 8 Current limiting characteristics

Function of Hitachi Current-Limiting Type Breaker is as follows:

Fig. 9-1 Fig. 9-2 Fig. 9-3

When a short circuit current flows through this The electromagnetic repulsing force causes The breaking mechanism has functioned to
breaker, an electromagnetic repulsing force the moving contact to swing apart from the open the circuit.
works in the direction shown above. fixed contact before the breaking mechanism
functions, accomplishing extremely quick
breaking.

17
Construction of Electronics Type Breakers (FX400 – FX1200)

Excellent Current Limiting Function Double Instantaneous Trip*

Owing to high-speed current interruption, excellent current limiting Double electronic and mechanical instantaneous tripping
is achievable. Thus breaker stress with respect to temperature or characteristic protects equipments from short circuit.
mechanic is reduced circuits are securely protected.

Higher MT current Reduces Miss trip by motors rush Current Easy Coordination*

Instantaneous tripping current is now greater *than conventional Tripping characteristics include adjustable long time delay & short
models. Reduces probability of miss trip at high inrush current. time delay in proportion to long time delay (setting current x 1,000%)
Improvement of the voltage equilibrium characteristic of the earth are contribute to easier coordination with other electric appliance
leakage breaker. such as down stream circuit breakers, transformers and wires.
*In-house comparison *over 400A frame

Time Frame MT Current


FFB
tripping 400A 5,000A
characteristics
600A 8,000A
800A 10,000A
Motor startup
inrush current 1,000A 17,000A
1,200A 20,000A (FFB)

Current
10 15 (rated current
magnification)

18
C HARACTERISTICS

1. Overcurrent Tripping ■ Full-magnetic type


Because of its tripping device with proper time-delay characteristics, The rated current of a full-magnetic type which has no thermal element
Hitachi Fuse-Free Breaker automatically opens circuits for overcurrents will not undergo a change despite variations in ambient temperature.
up to about 800% of its ampere rating. For heavy short-circuit currents, Instead, the viscosity of the oil in its dash pot relay varies with
its instantaneous magnetic tripping device functions to break the circuit. temperature, causing the operating time to change as shown in Fig. 11.
These characteristics are specified in Circuit Breakers IEC60947-2, The rate of change in the operating time which the example below
as shown in Table 6, according to which Hitachi Fuse-Free Breaker is illustrates is as follows: If this tripping device adjusted to an ambient
designed. temperature of 40ºC is employed at a site whose ambient temperature is
50ºC, and if it trips over a circuit because of an overcurrent, its operating
time will be reduced to 85% of standard time.

Table 6 Overcurrent Tripping characteristics


All poles loaded
Conventional
Conventional non-tripping C o n v e n t i o n a l t r i p p i n g
time (h) Tripping current value varies
current current
At 20ºC
1.05 times current setting 1.3 times current setting 2*
*1 hour when ln ≤ 63A Base ambient temperature 40ºC

Tripping time
300
At 40ºC
200

Tripping time (%)


180
<Base ambient temperature> 160
140
Tripping device of Hitachi Fuse-Free Breaker is factory-adjusted for 120
100
application at an ambient temperature of 40ºC, the base ambient
80
temperature specified by IEC standard.
60
0 10 20 30 40 50

■ Thermal-magnetic type Current (percent rated current) Ambient temperature (ºC)

When employing or testing a thermal-magnetic type at ambient


temperatures other than 40ºC, the operating current for tripping varies
(as shown in Fig. 10). It is necessary to compensate for the rated current
according to the temperature compensation curve prepared for each frame. Fig. 11 Example of Application of Ambient Temperature
Application of the temperature curve is as follows: Compensation Curve for Full-magnetic Type

The compensation current I is represented by:

I1 x 100
I= <Maximum applicable temperature>
X (%)
Fuse-Free Breaker is applicable to ambient temperatures up to 50ºC.
Where I = value of compensation current, I1 = value of current required Application at a site whose ambient temperature exceeds 50ºC is a
at certain ambient temperature, and X = rate of increase or decrease special case, for which users are requested to contact Hitachi for advice.
of current at a certain ambient temperature compensation curve for
determining the amount of compensation for the rated current value.
The example shown below illustrates that the rated current of a device
adjusted at the base ambient temperature 40ºC at a site whose ambient
temperature is 50ºC decreases to 90% of the rating.

Tripping current value varies


Compensation rate of rated current (%)

At 20ºC Base ambient temperature 40ºC


Tripping time

At 40ºC 130

120

110

100

90

80
0 10 20 30 40 50
Current (percent rated current) Ambient temperature (ºC)

Fig. 10 Example of Application of Ambient Temperature


Compensation Curve for Thermal-magnetic Type

19
C AUTION

1. Standard mounting is shown in the diagram below. 5. Insulation clearance on line end of FFB is as follows:

15 degree 15 degree 15 degree 15 degree


or less or less or less or less Metal plate coated
B

A
Line end
Line end

FFB
Load end
Load end
Fig. 14
Vertical wall Vertical wall

Fig. 12 Standard Mounting Method

If mounting in another direction is inevitable, contact Hitachi for advice.

2. Reversible connection types are available. Table 7 Insulation Clearance


Reverse connection is basically prohibited (See following figure (Fig.13)) ( ) dimension is 400V class
Minimum dimensions
Power source Load (mm)
Classification FFB frame
A B
30A Frame, 50A Frame
ON side ON side
1 (Excluding L-50E) 30 25
60A Frame
OFF side OFF side
L-50E
2 40 40
100A Frame
Load Power source
3 125A 225A 250A Frame 50 40
4 F-250FB F-250KC 100 40
(a) Correct connection (b) Incorrect connection
400A Frame, 600A Frame,
5 80 (110) 50
800A Frame
1000A Frame, 1200A Frame,
6 150 (190) 100
1600A Frame

But reversible connection type available as follows: 6. Insulation of line side’s living parts
Maximum It is recommended that line side’s live parts of front connected type
Frame F series S series applicable Remarks
breakers are insulated by insulation tape or insulation barrier.
voltage
100AF F-100KB — 1. Please state "Reversible connection
type" when ordered.
FXK250-S, S-225SB,
225AF
FXK250-H SXK225
400AF F-400R S-400S
600AF F-600F S-600S AC460V 2. Installation of phase separators on the Insulation barrier
load side is required.
F-800F, Taping
800AF S-800S
F-800RH
1000AF F-1000K — Dimension is the same
A
1200AF F-1200K — as A of above table

3. Don’t install the breaker at a site whose ambient temperature of an


installation site exceeds 50ºC. If installing the breaker in such a high
ambient temperature is unavoidable, contact with Hitachi in advance. Fig. 15

4. Application of full magnetic type for DC circuit


Breakers for AC and breakers for DC are separately calibrated, and
different application cannot be performed.
If DC application, please specify pure DC, single-phase full-wave rectified
or three-phase full-wave rectified, etc.

20
SELECTION

1. Select a breaker type according to the purpose 2. Estimate the available short-circuit current and select
■ Protection of general wiring: Table 1 to 4 economical frames — whose interrupting capacity is higher
■ Protection of motor: Table 5 than that estimation — from among the following series:
■ Protection of branch lamp circuit: Table 6 F series: Standard type for general service
■ Protection against earth leakage S series: Small-scaled and low-cost, economical type
L series: High-performance, current-limiting, high-interrupting
<Consideration to available short circuit current> capacity type
In estimating short circuit currents, there are many considerations, such
as characteristics of transformer, connecting wire size and the distance
from the transformer to the faulty point and so on.
The below charts bring you an easy solution for selecting the breaker type.

Fig. 16 Example of selection

AC 460V (Transformer voltage: 415V)

50A 125A frame 100AF 125A frame 225AF 250AF frame

FXK250-H
FXK125-H

FXK125-H

FXK125-S FXK250-S

400A frame 600A frame 800A, 1000A, 1200A frame

21
3. Select the rated current as follows: ■ Rated Current of main circuit for motor
● Rated currents for heater and lamp circuits The motor groups connected to this circuit are divided into subgroups,
Select a circuit breaker whose current rating corresponds to the value of each consisting of motors which are started simultaneously.
the current allowable for the circuit. Each subgroup is regarded as one motor for convenience (and the sum of
● The rated current of a motor circuit is selected as follows: the full load current of each motor within this subgroup is regarded as the
full load current of this virtual motor). Then select the rated current of a
<For general type breakers for protection of wiring>
subgroup whose full-load current is largest from the Table 8, 9, 10, 11.
■ Rated current of branch circuit for motor The sum of this tentative rated current and the full-load current of all
Table 8, 9, 10, 11 shows rated currents of the breakers which have been the other subgroups is selected as the rated current of the breaker under
selected on condition that they will not effect erroneous operation at consideration.
motor starting time. Where two or more motors are connected to one
branch circuit, the sum of the rated currents of these motors forms the
basis for selecting the rated current of the breakers.

Table 8 Directly Starting a 3-phase Induction Motor (400 – 440V AC)


Motor FFB
Full-load Rated Interrupting capacity (kA) Sym
Capacity
current current
(kW) 2.5 5 7.5 10 15 22 25 30 35 43 50 85
(A) (A)
0.2 0.7 15
0.4 1.4 15
0.75 2.3 15
1.5 4.2 15
F-30FB
2.2 5.6 15 FXK125-S FXK125-H L-50E
3.7 9.0 20 S-60RB F-60RB
5.5 14 30
7.5 16 30
11 25 50 S-50SB
15 33 60
18.5 40 60
22 45 75 FXK125-S FXK125-H L-100E
S-100S
30 60 100
S-100SB
37 75 100
45 90 150
55 (110) 175 S-225SB
FXK250-S FXK250-H L-225E
75 (150) 225 SXK225
90 (180) 225
F-400R
110 (220) 350 S-400S SX400 L-400E
FX400
150 (300) 500 F-600F
S-600S SX600 L-600E
190 (380) 600 FX600

Note: (1) The starting conditions are set within 15 seconds at 500% (10 seconds at 600%) of full load current.

Table 9 Star-delta Starting a 3-phase Induction Motor (400 – 440V AC)


Motor FFB
Full-load Rated Interrupting capacity (kA) Sym
Capacity
current current
(kW) 2.5 5 7.5 10 15 22 25 30 35 43 50 85
(A) (A)
For a capacity of 15 kW or less, select the same breaker among those for direct-starting
18.5 40 75
S-100S
22 45 75 FXK125-S FXK125-H L-100E
S-100SB
30 60 100
37 75 125
45 90 150 S-225SB
FXK250-S FXK250-H L-225E
55 (110) 175 SXK225
75 (150) 225
90 (180) 350 S-400S F-400R
L-400E
110 (220) 400 SX400 FX400
S-600S F-600F
150 (300) 600 L-600E
SX600 FX600
F-800R
190 (380) 700 S-800S FX800 F-800RH
L-800E

22
Table 10 Selecting table of Fuse-Free Breaker for Motor Branch Circuit Directly Starting 3-phase Induction Motor (200 – 220V AC)
Motor FFB
Full-load Rated Interrupting capacity (kA) Sym
Capacity
current current
(kW) 5 10 14 25 30 35 42 50 85 175
(A) (A)
0.2 1.4 15
0.4 2.6 15
0.75 4.2 15 S-30E
1.5 7.4 15 S-30FB
FXK125-S FXK125-H L-50E
2.2 10 20 S-60RB F-60RB
3.7 16 30
S-50EB,
5.5 25 50
S-50SB
7.5 33 60
11 45 75
S-100S S-100SB FXK125-S FXK125-H L-100E
15 60 100 S-100EB
S-100SB
18.5 75 100
22 90 150
30 (120) 200 S-225SB
FXK250-S FXK250-H L-225E
37 (150) 225 SXK225
45 (180) 225
55 (220) 350 S-400S F-400R
L-400E
60 (240) 400 SX400 FX400
75 (300) 500 S-600S F-600F
L-600E
90 (360) 600 SX600 FX600

Table 11 Star-delta Starting a 3-phase Induction Motor (200 – 220V AC)


Motor FFB
Full-load Rated Interrupting capacity (kA) Sym
Capacity
current current
(kW) 2.5 5 10 14 25 30 35 50 85 125 175
(A) (A)
For a capacity of 15 kW or less, select the same breaker among those for direct-starting
18.5 75 125
22 90 150 S-225SB
FXK250-S FXK250-H L-225E
30 (120) 200 SXK225
37 (150) 225
45 (180) 350 F-400R
S-400S, SX400 L-400E
55 (220) 400 FX400
60 (240) 500 F-600F
S-600S, SX600 L-600E
75 (300) 600 FX600
F-800RH
90 (360) 700 S-800S, F-800R, SX800 L-800E
FX800

<Breaker Used for Protection of Motor Against Overload> Table 12 Applicable Conditions of Motor Breaker
A motor breaker is used to protect wiring and a motor against overload. Its
rated current is about the same value as full-load current of the motor. The Starting condition
Rated current
applicable conditions are subject to the following restrictions: Starting current/
(Amperes) Starting time
full load current
1) Only one motor is installed on the circuit under consideration. 500% Within 3 sec
2) Starting current is less than 600% of the full-load current and motor 50 or less
600% Within 2 sec
load is light (for specific requirements for each rated current, refer to 500% Within 8 sec
From 51 to 150
Table 12). 600% Within 5 sec
When the above restrictions cannot be met use a general type FFB.
When ordering, please specify the Frame (selected by the interrupting capacity)
and the rated current. (About the same as full load current of the motor.)

● When using the breaker for the transformer primary circuit.


Since exciting inrush current may be 20 to 30 times the transformer
rated current, the breaker rated current should be selected more than
two times the transformer rated current.

23
4. Application to discrimination coordination
In a discrimination coordination system, only the breaker nearest the Main circuit breaker

fault opens to isolate the faulty circuit from the rest of the power system.
This system results in maximum continuity of service.
ELECTRONICS TYPE breakers are best suited to application as the Branch circuit breaker
upstream (main) breaker.

Normal circuit Faulty circuit Fig. 17

Table 13 Discrimination between standard FFBs and ELECTRONICS TYPE FFBs


230V class
FFB for main circuit Type FX400 FX600 FX800 FX1000 FX1200 F-1600CB
FFB for branch circuit Interrupting
Interrupting Capacity (kA) 100 100 100 125 125 125
Type Capacity(kA)
F-30FB 5 5 5 5 5 5 5
F-50FC 10 5 7.5 7.5 10 10 10
F-60RB 25 5 10 10 25 25 25
F-50HB 35 5 10 10 35 35 35
FXK125-H 100 5 14 14 85 85 85
FXK125-S 50 5 10 10 50 50 50
FXK125-H 100 5 14 14 85 85 85
FXK250-S, FXK250-H, F-250FB, F-250KC 85 / 100 4 10 10 35 35 65
FX400, F-400R 100 — — 10 18 22 25
F-600F, FX600 100 — — — — 22 25
F-800F, FX800, F-800R 100 — — — — — 25
FX1000 125 — — — — — —
FX1200 125 — — — — — —
S-30E, S-50EB, S-50SB 5 4 5 5 5 5 5
S-100EB, S-60RB 10 4 7.5 7.5 10 10 10
S-100SB 35 5 14 14 25 25 25
S-225SB, SXK225 35 4 10 10 25 25 25
SX400, S-400S 50 — — 10 18 22 25
SX600, S-600S 50 — — — — 22 25
SX800, S-800S 85 — — — — — 25
L-50E 175 5 14 14 125 125 125
L-100E 175 5 14 14 125 125 125
L-225E 175 4 10 10 42 65 125
L-400E 175 — — 10 18 22 42
L-600E 175 — — — — 22 42
L-800E 175 — — — — — 42

380V class
FFB for main circuit Type FX400 FX600 FX800 FX1000 FX1200 F-1600CB
FFB for branch circuit Interrupting
Interrupting Capacity(kA) Capacity (kA) 50 50 50 85 85 85
Type
F-30FB 2.5 2.5 2.5 2.5 2.5 2.5 2.5
F-50FC 7.5 4 7.5 7.5 7.5 7.5 7.5
F-60RB 10 4 7.5 7.5 10 10 10
FXK125-H 50 4 7.5 7.5 50 50 50
FXK125-S 30 4 7.5 7.5 25 25 25
FXK125-H 50 4 7.5 7.5 35 50 50
FXK250-S, F-250FB 30 4 7.5 7.5 22 22 30
FXK250-H, F-250KC 50 4 7.5 7.5 22 22 30
FX400, F-400R 50 — — 7.5 18 22 22
F-600F, FX600 50 — — — — 22 22
FX800, F-800R 50 — — — — — 22
FX1000 85 — — — — — —
FX1200 85 — — — — — —
S-50SB 2.5 2.5 2.5 2.5 2.5 2.5 2.5
S-60RB 5 4 5 5 5 5 5
S-100S, S-100SB 10 4 7.5 7.5 10 10 10
S-225SB, SXK225 15 4 7.5 7.5 15 15 15
SX400, S-400S 35 — — 7.5 22 22 22
SX600, S-600S 35 — — — — 22 22
SX800, S-800S 35 — — — — — 22
L-50E 125 4 10 10 30 30 85
L-100E 125 4 10 10 30 30 85
L-225E 125 4 7.5 7.5 22 22 50
L-400E 125 — — 7.5 18 22 22
L-600E 125 — — — — 22 22
L-800E 125 — — — — — 22

24
A CCESSORIES

Interior Accessories
■ Available accessories inside of FFB are as follows:

Undervoltage Trip (UVT) Shunt Trip (SHT)

The Undervoltage Trip is used to automatically trip the breaker The Shunt Trip is used to trip the breaker electrically from a remote
when the line voltage drops to 35 to 70% of its normal value. point. Since this trip coil does not have a continuous rating, the coil
The standard mounting method of the breaker with this trip is circuit must be broken by making connections to the load end of
vertically on the wall with its line end positioned upward. the breaker (Fig. 20 (a)). If a separate power supply is to be used,
the customer is requested to specify an auxiliary switch to prevent
the coil from being burnt by overheating (Fig. 20 (b)).
The standard mounting method of the breaker with this trip is on
the wall with its line end positioned upward.

Lead wire
0.5mm2 PVC-insulated wire (yellow),
0.5 meter long

Alarm Switch (AL) Auxiliary Switch (AUX)

When the breaker is tripped, this switch closes to energize an The auxiliary switch, a device interlocked with opening and closing
indicating light or sound an alarm. It employs a microswitch operation of a breaker, is used to open or close control circuits as the
equipped with a C-contact. breaker operates. It employs a microswitch equipped with a C-contact.

■ Terminal Symbols and Connection Condition of AL Switch ■ Terminal Symbols and Connection Condition of AUX Switch

Condition of Breaker Connection condition of AL switch Condition of Breaker Connection condition of AUX switch
S-2 (S-5) A-2 (A-5)
S-1 A-1
ON and OFF ON and OFF
(S-4) (A-4)
S-3 (S-6) A-3 (A-6)

S-2 (S-5) A-2 (A-5)


S-1 A-1
Tripped OFF or Tripped
(S-4) (A-4)
S-3 (S-6) A-3 (A-6)

( ): for 2C contacts ( ): for 2C contacts

25
Terminal Block for Interior Accessories

TB TB2
3P 16.5
40
8.5
10
3P 6P

10 10
32
(F)
10
(F)
47.5
6P 16.5

(F)
10

62
10.5 3 8 10 10

32
(E)
7.9

(E)
7.9

10
7

10
16.5 7

62
12
16.5

10
TB TB2

10
(F)
Fig. 18 External View of a Breaker with Terminal Block Fig. 19 Dimensions of FFB with Terminal Block for
for an Interior Accessory Interior Accessory

Table 14 Rating of Alarm Switch and Auxiliary Switch

Voltage Rated current Time constant


250V 2A
AC —
500V 1A
110V 0.5A
DC 10 ms or less
220V 0.25A

(a) Uni-power (b) Separate power


(excepting F-250FB F-250KC)

Fig. 20 Wiring Diagram of Shunt Trip

Table 15 Coil rating of SHT and UVT

SHT UVT
Type
Voltage Input (VA) Voltage Input (VA)
S-30E, S-50EB, 100
— —
S-225SB, SXK225 (for 400V: 200VA)
AC 100-110V 50Hz 60Hz
F-30FB, S-50SB, F-60RB, F-50KB, AC 200-220V AC 100V AC 100V
L-50E, S-100EB, S-100S, S-100SB, AC 230-240V 200V 110V 20
F-100S, F-100RB, F-100KB, L-100E AC 380V 230V 200V
AC 400-440V 240V 220V
FXK125-S, FXK125-H, FXK250-S, FXK250-H, AC 480V
— —
F-250FB, F-250KC

( )
200
L-225E, S-400S, SX400, F-400R, Common use for 50Hz 60Hz
50 and 60 Hz 20
FX400, L-400E AC 100V AC 100V
200V 110V
S-600S, SX600, F-600F, FX600, L-600E, DC 100V 230V 200V
S-800S, SX800, F-800R, F-800RH, FX800, DC 110V 240V 220V 30
L-800E, FX1000, FX1200, F-1000C, F-1000K,
400V 400V
F-1200C, F-1200K, F-1600CB, F-1600B
415V 440V

26
Table 16 Applicability of interior accessories
✶ FXK125-S
✶ FX600 F-1200K
✶ FXK125-H
F ✶ FX800 F-1600B ✶ FX1000
F-30FB F-100S ✶ FXK250-H ✶ FX400
F-600F F-800R ✶ FX1200
F-60RB F-100KB ✶ FXK250-S ✶ F-400R
F-1000K F-1600CB
Type S F-250FB
F-800RH
F-250KC

S-30E S-50SB, S-100EB, S-225SB ✶ SX400 ✶ SX600 S-600S


S-100S
S-50EB S-100SB, S-60RB ✶ SXK225 ✶ S-400S ✶ SX800 S-600S
L
L-225E L-600E
L-50E L-100E
L-400E L-800E
M
Number ✶ MFXK100-S
of poles MS-30E MS-50SB ✶ MFXK225-S
MS-50EB MS-100SB MS-225SB
Accessories MF-250FB
2 3 2 3 2 3, 4 2, 3 2, 3, 4 2, 3, 4 3, 4

AL 1C 1C 1C 1C 1C 1C 1C 2C 2C 2C

AUX 1C 1C 1C 1C 1C 1C 1C 2C 2C 2C

SHT

UVT

AL 1C 1C 1C 1C 1C 1C 2C 1C 2C 1C 2C
+
AUX 1C 1C 1C 1C 1C 1C 2C 2C 2C

AL
+ 1C 1C 1C 1C 2C 2C 2C
SHT

AL
+ 1C 2C 2C 2C

UVT

AUX
+ 1C 1C 1C 2C 2C 2C

SHT

AUX
+ 1C 2C 2C 2C

UVT

AL
+ 1C 1C 1C 2C 1C 2C 1C 2C
AUX
+ 1C 1C 1C 2C 2C 2C

SHT
AL
+ 1C 2C 1C 2C 1C 2C
AUX
+ 1C 2C 2C 2C

UVT

Handle of Breaker AL AUX SHT UVT

Notes:
1. 2C means that it can be mounted 1C, if required.
2. *: Terminal block (TB) for UVT wiring is equipped.
3. The accessories of marked ✶ types can be installed by customers.
4. AL 2C or AUX 2C is available in case of FXK125-S / H and FXK250-S / H

27
Exterior Accessories

■ Accessories mounted on the outside of breaker are as follows: 3. Flush-mounting Base Assembly (GKW, GK)
■ Rear Connecting Stud (STB) and Bar Stud (BSD) The flush-mounting base assembly is an accessory for mounting a
■ Plug-in Mounting Base Assembly (PK) breaker on a switchboard. A breaker is secured via insulating bushings
■ Flush Mounting Base Assembly (GK) to an exclusive mounting frame by using screws as same method as
■ Mechanical Interlock (MI) the rear connecting stud or bar stud. A rectangular hole sized a little
■ Motor Operating Mechanism (MMK, MMK-C) larger than that of a breaker is cut into the switchboard and the breaker
■ Electro-magnetic Operating Mechanism (MK-C) is embedded into this hole and secured to the switchboard by the
■ Handle Operating Mechanism mounting frame. The flush plate is mounted on the breaker.

1. Rear Connecting Stud (STB) and Bar Stud (BSD)


Rear connecting stud is used as rear connecting terminal.

Fig. 23 FFB with Flush-mounting Base Assembly

Fig. 21 FFB with Rear Connecting Studs


4. Mechanical Interlock (MIW)
For 600A frame or less and S-800S, molded insulating bushings are This mechanical interlock prevent from any of two breakers to be closed.
provided.

2. Plug-in Mounting Base Assembly (PK)


The plug-in mounting base assembly is an accessory demounting a
breaker by saving the trouble of removing the connection wiring from it
when inspecting or replacing a breaker mounted on a switchboard or a
panel board.

Fig. 24 FFB with Mechanical Interlock

5. Drawout Mechanism (PDK)


The drawout mechanism is an accessory for easy mounting and removal
of F-1600E.

Fig. 22 FFB with Plug-in Mounting Base Assembly

Fig. 25 FFB with Drawout Mechanism

28
6. Motor Operating Mechanism (MMK-S)
This mechanism is suitable to remote control a breaker by utilizing a motor.
Since the control circuit is self holding type, the operation of this
mechanism is completed by brief closing of push button switch contact.
As soon as completing of operation, the control circuit is opened and
the motor is stopped by instant operation of a limit switch.
The manual operation is also available.

Fig. 26 Motor Operating Mechanism

Table 17 Standard Ratings of Motor Operated Mechcanism


Type MMK-S
3P 4P
F100KB
F series FXK125-S FX400
F-250FB F-400R
FXK125-H F-400R
F-250KC
Type of FFB
L-50E L-225E L-50E L-225E
L series
L-100E L-400E L-100E L-400E
S-225SB SX400
S series — —
SXK225 S-400S
DC100

DC110
Max. operational AC100 0.2 0.3 0.2 0.3
current peak (A) AC110 (0.6) (0.9) (0.6) (0.9)
AC200 0.1 0.15 0.1 0.15
AC220 (0.3) (0.45) (0.3) (0.45)
Power supply (VA) 500 100 50 100

Fig. 27 Control Circuit of Motor Operating Mechanism

29
DIMENSIONS OF MMK-S

F-100KB

FXK125-S, FXK125-H

Drilling plan

S-225SB

F-250FB, F-250KC Mounting screw Mounting screw for FFB x 6 (M4)


M4 screw hole or
for MMK-S x 2 (M4) ø5 holes x 6
Phase separator

Drilling plan

SX400, FX400

L-50E

L-100E

30
7. Motor Operating Mechanism (MMK-C)
This mechanism is suitable to remote control a breaker by utilizing a
motor. There is one type as follows.
MMK-C (Compact Type): The breaker is operated by rotation of a single
phase series commutator motor with reduction gear.

Fig. 28 Motor Operating Mechanism

*excepting 4 poles FFB

Table 18 Standard Ratings of Motor Operated Mechcanism


Type MMK-C
F-800R F-800RH
FX800 F-1000C (4P) F-1000K (4P)
F-400R F-600F
F series F-1000C* F-1000K* F-1200C (4P) F-1200K (4P)
FX400 FX600
F-1200C* F-1200K* F-1600CB (4P) F-1600B (4P)
Type of FFB
F-1600CB* F-1600B*
L-225E L-600E
L series — —
L-400E L-800E
S series S-400S S-600S S-800S —
DC100 ∙ 110V 3 6.5 8 10
Max. operational
AC120V 3 6.5 8 10
current peak (A)
AC240V 1.5 3.5 4 5
Operating time (sec) 1.2 1.5 1.5 1.5
Power supply (VA) 100 200 200 400

F-400R FX400 F-600F FX600 F-800R PS Push-button Switch


F-800RH FX800 FX1000C F-1000K FX1000 X Auxiliary Electromagnetic Contactor
F series
F-1200C F-1200K FX1200 F-1600CB n For operating FFB“ ON”
Type
F-1600B f For operating FFB“ OFF”
L series L-225E L-400E L-600E L-800E a Closed by operation (normally open)
S series S-400S S-600S S-800S b Opened by operation (normally closed)
CP Circuit Protector
2 Timer
Si Silicon Rectifier
R Resister
M Motor
IS S LS Limit Switch

31
DIMENSIONS OF MMK-C

L-225E
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

FX400, F-400R
SX400, L-400E
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

32
FX600, F-600F
SX600, L-600E
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

FX800, F-800R
F-800RH, SX800
L-800E
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

33
FX1000, F-1000K
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

FX1200, F-1200K
(Standard Type)

(Rear Connecting Type)

(Built-in Type)

34
F-1600B, F-1600CB ø13.5 holes

(Standard Type)
Manual
handle

(Rear Connecting Type)

(Built-in Type)

35
8. Terminal Cover (TMC)

B
A

D
C

TMC-0G All Types


(Excepting TMC-0G)

Fig. 29 Fig. 30 Shape of Terminal Cover

Dimensions
Types Applicable breakers Remarks
A B C D
TMC-0G S-30E, S-50EB 75 (50) 19.5 56 5
TMC-1 75 (50) 48 59.5 28
F-30FB, S-50SB, S-60SB,
TMC-1S 75 (50) 25 56 5 Short type
F-60RB, S-100EB, S-100SB
TMC-2D 75 (50 56 59.5 36 Long type
S-100S, F-100S,
TMC-2C 90 (60) 63 63 36
FXK125-S, FXK125-H
TMC-3C F-100KB, L-50E, L-100E 90 (60) 56 85.5 36
TMC-4K S-225SB 105 79 56 50
TMC-4J SXK225 105 79 53 50
TMC-4JS FXK250-S, FX-250-H 105 28 51 5 Short type
TMC-4H F-250FB, F-250KC 105 71 99 40
L-225E, S-400S, F-400FB,
TMC-5B 147 147 99 110
L-400E
S-600S, F-600F, L-600E,
SX600, FX600, S-800S,
TMC-5D 210 154 91.5 129
F-800R, F-800RH, L-800E,
SX800, FX800
TMC-6 F-1000K, F-1200K 210 159 145 130
TMC-6B FX1000, FX1200 210 159 138.5 130
Remarks Dimensions with ( ) are for 2-pole types

Terminal Cover (BTC) Types Applicable FFB Type


BTC-1 F-30FB, S-50SB, S-60RB, F-60RB, S-100EB, S-100SB
BTC-2C S-100S, F-100S, FXK125-S, FXK125-H
BTC-3C F-100KB, L-50E, L-100E
BTC-4G S-225SB, MS-225SB
BTC-4J SXK225, FXK250-S, FXK250-H
BTC-5B L-225E, L-400E, S-400S, F-400R, SX400, FX400

Fig. 31

9. Handle operating mechanism ■ Door Interlock


This device is mounted on the face or door of a switchboard or a control For a handle mounted on a hinged door, this door interlock allows the
board, making it possible to open or close a breaker from the outside. door to be opened only when the breaker’s operating handle is placed at
Following interlocks are attached as standard. the OPEN COVER position. When the handle is placed at the ON or OFF
position, this device will prevent the door from being opened.
■ Handle Interlock
This handle interlocks is for preventing unnecessary manipulations of a ■ Color of Handle and Nameplate
breaker. Users are requested to provide a padlock for this device. The standard colors of handle and nameplate are as follows:
Handle: No1.5 (Black)
Nameplate: Black letters on silver aventurine

36
Handle Operating Mechanism

(with padlock)
Fig. 32

■ Dimension of HA Type Handle (3P)

Center line Center line


of FFB (ELB) of FFB (ELB)

Max. A
Max. A

Name plate Center line


Center line of FFB (ELB)
Name plate
of FFB (ELB) handle
handle

Max. B
Max. B

Center line
of FFB (ELB) Center line
handle of FFB (ELB)
Stopper for handle
Stopper for door interlock 4-ø5.5 Mounting holes
door interlock Use the padlock Release
Release lever lever Use the padlock
(30mm dimension) Stopper for
(30mm dimension) Center line
Door interlock
Door Center line (Mounted on of FFB (ELB)
Handle
of FFB (ELB) case side) handle
lever
center handle 4-ø5.5 Mounting
holes (For
Stopper mounting
Door
for door name plate)
4-ø5.5 Mounting
interlock Handle lever
ø11 hole holes center
(Mounted ø60 hole
on case 4-ø6 ø11 hole
side) Door drilling Mounting holes
for handle mechanism
Center line of Door drilling
(ELB) FFB
(ELB) FFB Center line of FFB handle (ELB) for handle mechanism
mounting panel
mounting panel FFB handle (ELB)

Fig. 33-1 Fig. 33-2

Types Applicable breakers Panel cutting Fig. A B C D E F G H ■ Padlock


HA-104 S-100S, F-100S Fig.33-1 102 115 91 108 35 — — 75
F-30FB, S-50SB, S-60RB,
HA-108 Fig.33-1 104 114 88 105 35 1.5 — 75
F-60RB, S-100EB, S-100SB
5
F-100KB 102 115 110 127 35 — — 75
HA-106 Fig.33-1
L-50E, L-100E 102 115 127 144 35 — — 75
HA-206 F-250FB, F-250KC Fig.33-1 110 118 131 148 35 — — 75
HA-207 S-225SB Fig.33-1 100 118 90 107 35 1.5 — 75
HA-209 SXK225 Fig.33-1 106 110 96 115 35 — — 75
HA-210 FXK250-S, FXK250-H Fig.33-1 106 110 98 115 35 — — 75 30
L-225E, S-400S,
HA-405 Fig.33-1 113 120 140 157 38 — 6 78
F-400R, L-400E
HA-406 SX400, FX400 Fig.33-1 113 120 140 157 38 — 6 78
S-600S, F-600F,
L-600E, SX600, FX600
(Padlock is not attached as standard)
HA-402 Fig.33-1 113 120 145 162 38 7.5 — 78
S-800S, F-800R, F-800RH,
L-800E,SX800, FX800 Fig. 34
FX1000, F-1000K,
HA-801 FX1200, F-1200K Fig.33-2 195 200 187 206 100 — — 165
FX1600CB, F-1600B

37
Handle Operating Mechanism

Fig. 35 (with padlock)

■ Dimension of HA Type Handle (3P)

Door
Dimension in (mm) Panel
Face plate Panel
Latch Holder

Flush

Max. C
plate
ø

Dimensions of padlock
Center

Max. B
Door interlock (Padlock isn’t attachment)
release lever 1. Diam. B= Ø6 or under line of FFB
Padlock Dimension A 2. Width C= 19 or more
3.Length of straight part D
Setting position
Setting position =10.5 or more Flush
of right hinge of door
of left hinge of door plate

Centerline

4-Ø15 holes Fig. 36-2

Centerline

Ø90hole

Center line of
Drilling plan of doors
FFB handle

Hinge
4-ø15 holes
Fig. 36-1
s
le
Ho
3 8
ø1

Center line of
FFB handle

Over 150
(When hinge
Fig. 36-3 is 10)

Length between
hinge and breaker

Dimension ■ Padlock
Handle Type Applicable Breakers Bolt
Fig. A B C D L: Straight length
F-100KB 132
HM-S11 M4 x 50 Fig.36-1 — — —
L-50E, L-100E 149
F-30FB, S-50SB, S-60SB (Padlock is not attached as standard)
HM-S12 M4 x 65 Fig.36-1 108.5 — — —
F-60RB, S-100EB, S-100SB
HM-S13 FXK125-S, FXK125-H M4 x 70 Fig.36-1 118 — — —
HM-S21 F-250FB, F-250KC M4 x 50 Fig.36-1 150.5 — — —
HM-S22 S-225SB M4 x 45 Fig.36-1 110.5 — — —
HM-S23 SXK225 M4 x 45 Fig.36-1 118 — — — Fig. 37
HM-S25 FXK250-S, FXK250-H M4 x 45 Fig.36-1 118 — — —
S-600S, S-800S, F-600F ■ Padlock Dimension
HM-402 M6 x 130 Fig.36-2 176 137 137 0
F-800R, F-800RH, L-600E, L-800E
HM-405 L-225E, S-400S, F-400R, L-400E M6 x 130 Fig.36-2 170 137 140 6 A B L
HM-406 SX400, FX400 M6 x 130 Fig.36-2 170 137 140 6 HM-402, 405, 406, 407 45 6 — 6.5 Over 16
HM-407 SX600, FX600, SX800, FX800 M6 x 130 Fig.36-2 176 137 137 0

38
DIMENSIONS

S-30S / S-50E

Hr.
Max. value of less
than 30A

Min.
Max. value
of 31 to 50A

Tripping Time
Base ambient
temperature 40ºC

300

Min. 200
value

Tripping Time (%)


180

Sec.
160
140
120

100

80

60
0 10 20 30 40 50
-5

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
(2) Mounting holes (2) Mounting holes Terminal Cover
for M4 screw for M4 screw

M5 screw

■ Drilling Plan 2-M4 screw hole 2-M4 screw hole


or ø5 hole or ø5 hole

2 pole 3 pole

For front mounting bolts

■ Terminal Arrangement

39
S-30E / S-50EB

Hr.
(MS-30E / MS-50EB)

Min.
Max.

Tripping Time
Min. Base ambient
temperature 40ºC

Tripping Time (%)


Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Mounting fixture 2-M4 screw hole 2-M4 screw hole M5 screw

2 pole 3 pole

2-M4 screw hole 2-M4 screw hole


■ Drilling Plan or ø5 hole or ø5 hole

2 pole 3 pole

■ Terminal Arrangement

Applicable wire
Max. applicable crimping ø1.6 – 22mm2
terminal: 14 mm2

ø5.5
M5 screw

(Max.)

Bus and crimping Manufacturing of terminal


Wire connection
terminal connection (Max. 14)

40
S-30FB / S-50SB

Hr.
Max. value of less than 30A

Min.
(MS-50SB) Max. value of 31 to 50A
Max. value for DC
application

Tripping Time
Min. Base ambient
value temperature 40ºC
for AC

Sec.
Min.

Tripping Time (%)


value
for DC

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

2 pole 3 pole

■ Drilling Plan

2 pole 3 pole
For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

2 pole 3 pole

41
F-60RB

Hr.
Max. value of less than 30A

S-60RB

Min.
Max. value of 31 to 60A
Max. value for DC

Tripping Time
application

Base ambient
Min. temperature 40ºC
value
for AC

Sec.

Tripping Time (%)


Min.
value
for DC

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

2 pole 3 pole

■ Drilling Plan

2 pole 3 pole
For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

42
L-50E

Hr.
Max. value of 31 to 50A

Min.
Max. value of less than 30A

Tripping Time
Base ambient
temperature 40ºC
Min.

Sec.

Tripping Time (%)


value

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

3 pole 3 pole
For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Max. applicable
pressure type Breaker underside
wire connector:
22mm2

M6 screw

Bus or pressure wire connector connection


Applicable wire
connector:
1.6 to 22mm2

Insulating bushing
Wire connection (15 to 50A)
M8 screw
3 pole

43
Hr.

Hr.
S-100EB / S-100SB Max. value of less

Min.
Max. value

Min.
than 30A

(MS-100SB) Max. value of 31


to 50A

Tripping Time

Tripping Time
Max. value for
DC application

Min. Min.
value value

Sec.

Sec.
Min. value
for DC

S-100SB Current MS-100SB


(percent rated current)

Overcurrent Tripping
Characteristic Curve

■ Dimensions

2-Mounting holes 2-Mounting holes Base ambient


for M4 screw for M4 screw temperature 40ºC

Tripping Time (%)


Ambient Temperture (ºC)

Temperature
Compensation Curve

2 pole 3 pole

2-M4 tap holes 2-M4 tap holes


■ Drilling Plan or ø2-5 holes or ø2-5 holes ø2 holes 4-M4 tap holes
or ø4-5 holes
ø17 holes

2 pole 3 pole 2 pole 3 pole


For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

2 pole
Applicable
M8 screw pressure type Mounting plate
wire connector:
38mm2
M4 Mounting screw
Breaker
underside

R2
Insulating
tube M10 screw

44
S-100S
Base ambient
temperature 40ºC

Tripping Time

Tripping Time (%)


Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

2 pole 3 pole 2 pole 3 pole


For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Breaker underside
Max. applicable
pressure type
wire connector:
38mm2
Mounting
plate

M8 screw

Insulating
bushing

Bus or pressure wire connector connection Insulating pipe


Insulating pipe

M10 screw
2 pole 3 pole

45
Hr.

Hr.
FXK125-S / FXK125-H
Max. value of 51 to 125A

Min.

Min.
Max. value of 31 to 50A

(MFXK100-S)
Max. value

Tripping Time

Tripping Time
Max.
interrupting Min. value Max.
time interrupting

Sec.

Sec.
Min. value time

Current Current
(percent rated current) (percent rated current)

Overcurrent Tripping Overcurrent Tripping


Characteristic Curve Characteristic Curve
(15-30A) (31-125A)

■ Dimensions

■ Drilling Plan

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Max. applicable
pressure type
wire connector:
60mm2 (22mm2)
M8 screw 24
(M6 screw) 9.5
22

Bus or pressure wire connector connection


Applicable wire
( ): dimensions only for 50A or less connector:
1.6 to 22mm2

Wire connection (15 to 50A)

Dimensions are only for 60A to125A

46
L-100E

Hr.
Max. value of 31 to 100A

Min.
Max. value of

Tripping Time
less than 30A

Min.
value of Base ambient
31 to 100A temperature 40ºC
Min. value of

Tripping Time (%)


less than 30A

Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan (4)-M4 tap holes (6)ø17 holes


(4)-M4 tap holes or ø(4)5 holes
or ø(4)5 holes

3 pole 3 pole
For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Max. applicable
Breaker underside
pressure type
wire connector:
38mm2 (22mm2)
M8 screw
(M6 screw)

Bus or pressure wire connector connection Insulating


Applicable wire bushing
( ): dimensions only for 50A or less connector:
1.6 to 22mm2
Insulating pipe
(60 to 100A)
M10 screw (M8)
3 pole
Wire connection (15 to 50A) ( ): dimensions only for 50A or less

47
S-225SB

Hr.
Hr.
Cold start max. value

Min.
Max. value
(MS-225SB)

Min.
Hot start
max. value

Tripping Time

Tripping Time
Min. value
Min. value

Max.

Sec.
Sec.
Max. interrupting
interrupting time
time

S-225SB Current MS-225SB


(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions

Base ambient
temperature 40ºC
(4) Mounting holes
for M4 screw

of rated current (%)


Compensation rate
Ambient Temperture (ºC)

Temperature Compensation Curve

2 pole 3 pole

(4) M4 tap holes or


■ Drilling Plan (2) M4 tap holes or
ø(4) 5 holes

ø(2) 5 holes ø(6) 28 holes

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Maximum applicable pressure


type-wire connector = 60mm2
Special pressure type wire Breaker underside
connector is attached for
175 – 225A as shown on the
right table
Rated current (A) Applicable wire size of pressure
type wire connector (mm2)
175 – 225 Pressure type wire connector
80, 100, 125 (mm)

ø10 holes

Pressure type wire connector


directly connected

48
SXK225

Hr.
Hr.
Cold start max. value

Min.
Max. value
(MSKX225)

Min.
Hot start
max. value

Tripping Time

Tripping Time
Min. value Min. value

Sec.
Sec.
Max.
interrupting Max.
time interrupting
time

SXK225 Current MSXK225


(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions
Base ambient
temperature 40ºC

of rated current (%)


Phase separator

Compensation rate
Screw of slide cover

Trip button
Ambient Temperture (ºC)

Temperature Compensation Curve

2-M4 Mounting
screw hole

■ Drilling Plan 2-M4 screw holes


2-M4 screw holes
or ø5 holes
or ø5 holes
ø(6) 28 hole

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

ø10 hole
Max. applicable crimping
Terminal Arrangement 46
terminal: 150mm2

M8 screw
A system studs
(Standard)

B system studs

25 right
t6.5

and left
24 pole

Crimping terminal 61 56 center pole


Manufacturing of terminal directly connected
68 70 right and left pole

95 110 center pole

49
FXK250-S / FXK250-H

Hr.
Max. value
(MFXK225-S)

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current
(percent rated current) Ambient Temperture (ºC)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Phase insulator
(Removable)

Trip button

2-M4
Mounting
holes

■ Drilling Plan 2-M4 screw holes 2-M4 screw holes


or ø5 holes or ø5 holes
ø6-28 holes

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs


Maximum applicable pressure
type-wire connector = 60mm2
Special pressure type wire
connector is attached for
175 – 225A as shown on the
right table
Rated current (A) Applicable wire size of pressure
type wire connector (mm2)
175 – 225 Pressure type wire connector
80, 100, 125 (mm)

Pressure type wire connector


directly connected

50
L-225E

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current
(percent rated current) Ambient Temperture (ºC)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Max. applicable pressure-type


Wire connector: 100mm2

ø9 hole
A system studs
(Standard)

B system studs
(Customer-changeable)

Bus or pressure-type wire connector connection

Right and left poles

Center pole

51
S-400S/F-400R /L-400E

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current
(percent rated current) Ambient Temperture (ºC)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

Position of mounting screw


special nuts attached
For front mounting bolts For rear connecting studs

■ For front connection ■ For Rear Connecting Studs

M10 bolt

A system studs
(Standard)

B system studs
(Customer-changeable)

Pressure-type wire connector connection

Right and left poles

Center pole

52
Hr.
SX400 / FX400

Min.
Tripping Time
Max.

Sec.
interrupting
time

Current 200A setting


(percent rated current) 400A setting

Overcurrent Tripping Characteristic Curve

■ Dimensions

Right and left poles


Phase separator

4-M6 screw hole


Center poles

Screw of slide cover

Trip button

■ Drilling Plan
4-M6 screw hole or ø7 hole
4-M6 screw hole or ø7 hole

6-ø35 hole

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs


Insulating tube
Max. applicable (center pole)
crimping terminal:
200mm2 x 1
M10 bolt
(w-terminal)

A system studs
(Standard)

B system studs
(Customer-changeable)

Crimpint terminal connection


(ex. crimping terminal 100mm2 x 2 pcs.)

Right and left poles

Center pole

53
S-600S/F-600F/L-600E

Hr.
Max. value

Min.
Min. Magnetic Base ambient

Tripping Time
value trip range temperature 40ºC
(in 4 steps)

Position

of rated current (%)


Compensation rate
of setting

Sec.
Max. interrupting time

Current
(percent rated current) Ambient Temperture (ºC)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

194 when the auxilary


handle is attached.

■ Drilling Plan
(4) M6 tap holes
(4) M6 tap holes or ø(4) 7 holes
or ø(4) 7 holes
ø(6) 48 holes

For front mounting bolts For rear connecting studs

■ For front connection ■ For Rear Connecting Studs

ø13.5 hole

M12 bolt

Standard mounting
of bar studs are
flatwise A system

Bar studs are mounted


edgewise, If orders as
(B system studs)

Pressure-type wire connector connection

204 when the auxilary


handle is attached.

54
Hr.
SX600 / FX600

Min.
Tripping Time
Max.

Sec.
interrupting
time

Current 300A setting


(percent rated current) 600A setting

Overcurrent Tripping Characteristic Curve

■ Dimensions

4-M6 screw hole Phase separator

Center poles

Trip button

■ Drilling Plan 4-M6 screw hole or ø7 hole


4-M6 screw hole or ø7 hole

ø48 hole

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs


ø13.5 hole
4-M6 screw hole

Max. applicable
crimping terminal:
M12 bolt 200mm2 x 2

A system
studs
(Standard)
B system studs

Crimpint terminal connection


(ex. crimping terminal 200mm2 x 2)

55
S-800S / F-800R /

Hr.
Max. value

Min.
F-800RH / L-800E Min.
Magnetic
trip range
(in 4 steps)

Tripping Time
value

Base ambient
Position temperature 40ºC
of setting

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current
(percent rated current) Ambient Temperture (ºC)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

194 when the auxilary


handle is attached.

■ Drilling Plan
(4) M6 tap holes
(4) M6 tap holes or ø(4) 7 holes
or ø(4) 7 holes ø(6) 48 holes

For front mounting bolts For rear connecting studs

■ For front connection ■ For Rear Connecting Studs

M12 bolt ø13.5 hole

Standard mounting
of bar studs are
flatwise A system

Bar studs are mounted


edgewise, If orders as
(B system studs)

204 when the auxilary


handle is attached.

56
Hr.
SX800 / FX800

Min.
Tripping Time
Max.

Sec.
interrupting
time

Current 400A setting


(percent rated current) 800A setting

Overcurrent Tripping Characteristic Curve

■ Dimensions

4-M6 screw hole Phase separator

Trip button

■ Drilling Plan 4-M6 screw hole or ø7 hole


4-M6 screw hole or ø7 hole

ø48 hole

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs


ø13.5 hole
4-M6 screw hole

M12 bolt

A system studs
(Standard)

B system studs

57
F-1000C / F-1200C

Hr.
Hr.

Min.
Min.
Tripping Time

Tripping Time
Max. Max.

Sec.

Sec.
interrupting interrupting
time time

Setting range 1000A setting 500A setting Setting range 1200A setting 600A setting
at short limit at short limit

F-1000C Current (A) F-1200C

Overcurrent Tripping Characteristic Curve

■ Dimensions

■ Drilling Plan

For front mounting bolts For rear connecting studs

■ For front connection ■ For Rear Connecting Studs

M12 bolt

58
Max. value

Hr.

Hr.
Max. value

F-1000K / F-1200K
Min. value

Min.

Min.
Magnetic
Magnetic trip range
trip range (in 4 steps)
Min. (in 4 steps)
value

Tripping Time

Tripping Time
Position
of setting Position
of setting

Sec.

Sec.
Max. Max.
interrupting Lo Hi interrupting
Lo Hi
time time

F-1000K Current F-1200K


(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions
Base ambient
temperature 40ºC

of rated current (%)


Compensation rate
Ambient Temperture (ºC)

Temperature Compensation Curve

■ Drilling Plan

For front mounting bolts For rear connecting studs

■ For front connection ■ For Rear Connecting Studs

M12 bolt

59
FX1000 / FX1200

Hr.
Min.
Tripping Time
Max.
interrupting

Sec.
time

Current FX1000
500A setting
(percent rated current)
FX1200
600A setting
Overcurrent Tripping
Characteristic Curve FX1000
1000A setting
FX1200
1200A setting

■ Dimensions

4-M8 screw hole Phase separator


ø13.5 hole

Auxiliary handle

Trip button

4-M8 screw hole or ø10 hole


■ Drilling Plan 4-M8 screw hole or ø10 hole

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

Auxiliary handle
4-M8 screw hole
M12 bolt ø13.5 hole

A system studs
(Standard)
B system studs

60
Hr.
F-1600CB

Min.
Tripping Time

Sec.
Max.
interrupting
time

Setting range 1600A setting 800A setting


at short limit

Current (A)

Overcurrent Tripping Characteristic Curve

■ Dimensions

■ Drilling Plan 4-M8 tap holes or ø4-10 holes


4-M8 tap holes or ø4-10 holes
320 and more

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

4-Mounting holes ø12 hole


for M8 screw

Standard
mounting of bar
studs are flatwise
A system
less than 15
for connecting
of conductor
Bar studs are mounted
M10 x 50 bolt edgewise, If orders as
(B system studs)

61
Hr.
F-1600B

Min.
Tripping Time
Magnetic
trip range
(in 4 steps)
Position of setting

Sec.
Hi
Max.
Lo
interrupting
time

Current
(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions

■ Drilling Plan
4-M8 tap holes or ø4-10 holes 4-M8 tap holes or ø4-10 holes
320 and more

For front mounting bolts For rear connecting studs

■ Terminal Arrangement ■ For Rear Connecting Studs

4-Mounting holes ø12 hole


for M8 screw

Standard
mounting of bar
studs are flatwise
A system
less than 15
for connecting
of conductor
M10 x 50 bolt Bar studs are mounted
edgewise, If orders as
(B system studs)

ø12 hole

62
Hr.
F-1600E Rated current

Min.
[T1] Setting range

Tripping Time
[I2] Setting range

Sec.
[T2] Setting range [I3] Setting range

Current
(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions

■ Drilling Plan ■ For Rear Connecting Studs

63
DIMENSIONS OF 4 POLE BREAKERS

F-60R 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-100S 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-100KB 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

64
F-250FB / F-250KC 4 pole

L-225E 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-400R / L-400E 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-600F / L-600E 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

65
F-800R / L-800RH 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-1000K, F-1200K 4 pole


F-1000C, F-1200C 4 pole

For front mounting bolts For rear connecting studs

Drilling plan

F-1600CB 4 pole
F-1600B 4 pole
4-M8 screw Phase
hole separator
ø13.5 hole

Auxiliary
handle

Trip
button

For front mounting bolts For rear connecting studs

Drilling plan

66
EARTH LEAKAGE BREAKERS
AND EARTH LEAKAGE RELAYS
This is a combination of a Fuse-Free Breaker and a leakage current detector for
preventing fire or electric shock due to deterioration of electric insulation.
It will provide perfect protection of a circuit against overload,
short-circuit, or earth leakage.

■ Principle of operation
This device is composed of a zero phase current transformer for
detecting leakage current, a control circuit, and a Fuse-Free Breaker
with a shunt trip.
As shown in Fig. 37, magnetic fluxes cancel out each other, inducing
no output voltage in the secondary coil while no leakage is present in
the load circuit.
i1 + i2 + i3 = 0
If leakage current (lg) occurs in the load circuit, magnetic flux øg is
induced, producing a certain voltage across the secondary coil.
i1 + i2 + i3 = ig
The induced voltage is supplied to the shunt trip coil of the Fuse-
Free Breaker, through a control circuit composed of diodes and Fig. 37 Principle of operation
semiconductor control elements, to break the circuit.

CLASSIFICATION AND COMPOSITION

Earth Leakage
E Series R Series
Standard Breaker High Interrupting
Breaker
Relay Series

30A – 800A frame 100A – 1200A frame –

67
R ATINGS AND SPECIFICATIONS
Table 19 E series
Type EB-50E EB-100E EX30 EX50 EX50B EX50C

Appearance

3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W


Phase- wiring Sysytem 1ø2W 1ø3W 1ø3W 1ø3W 1ø3W 1ø3W 1ø3W
1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W
Number of poles 2 3 3 3 3 3 3

Rated Voltage (AC V) 100 – 200 100 – 200 200 – 440 200 – 440 100 – 200 200 – 440

Rated Current (A) 5 10 15 20 5 10 15 5 10 15 20 5 10 15 20 5 10 15 20


60 75 100
(Base ambient temperature 40ºC) 30 40 50 20 30 30 40 50 30 40 50 30 40 50

Rated Impulse withstand Voltage Uimp (kV) 4 4 6 6 6 6


High 30 30 (15) 30 30
Rated Sensitivity Current (mA) (15) 30 (100) 30 100
Speed 100 ∙200 ∙500 100 ∙200 ∙500 100 (200) 100 ∙200 ∙500
Type Operating time (sec. or less) 0.1 0.1 0.1 0.1 0.1 0.1
Rated Sensitivity Current (mA) — — — — — (100 ∙200 ∙500 )
Time
Operating time (sec. or less) — — — — — (0.3)
Delay
Type Limiting non-actuating time
— — — — — (0.1)
(sec. or more)
Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical
Indication of Earth Leakage
(button) (button) (button) (button) (button) (button)
440V — — 2.5 / 1 2.5 / 1 — 10 / 3
415V — — 2.5 / 1 2.5 / 1 — 10 / 3
Rated JIS C 8201-2-2
400V — — 2.5 / 1 2.5 / 1 — 10 / 3
Breaking Ann2 AC
Capacity (kA) 240V — — 5/2 5/2 — 35 / 9
(Icu/Ics)
200V 5/2 5/2 5/2 5/2 10 / 3 35 / 9
100V 5/2 5/2 — — 10 / 3 —
a d
c a 50 75 75 75 75 75 75
b 96 97.5 130 130 130 130
Dimensions (mm)
c 60 60 60 60 60 60
b

d 76 76 84 84 84 84
Net Weight (kg) 0.3 0.4 0.6 0.7 0.7 0.7 0.7
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal
Phase Separator for Line Side — — ○ ○ ○ ● (*2)
Test Button Lead Wire TBL ○ ○ ○ ○ ○ ○
Alarm Switch AL ○ ○ ○ ○ ○ ○
Interior Auxiliary Switch AUX ○ ○ ○ ○ ○ ○
Accessories Earth Leakage Alarm Sw. EAL — — — — — —
TB — — ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○ ○
STB — — STB-2M STB-2M STB-2M STB-2M
Rear-connecting Stud
BSD — — — — — —
Flush Mounting Base GKW (STB) — — ○ ○ ○ ○
Assembly GK∙ GKW (BSD) — — — — — —
Plug-in Mounting
PK — — — — — —
Base Assembly
Mechanical Interlock MIW — — MIW-2E MIW-2E MIW-2E MIW-2E
Motor-operating MMK-S — — — — — —
Exterior Mechanism MMK-C — — — — — —
Accessories
Lock Cover LC LC-03 LC-03 LC-2G LC-2G LC-2G LC-2G
Handle Lock HL — — HL-2G HL-2G HL-2G HL-2G
Handle Operating HA — — HA-108 HA-108 HA-108 HA-108
Mechanism HM — — HM-S12 HM-S12 HM-S12 HM-S12
TMC TMC-0G TMC-0H TMC-1 TMC-1 TMC-1 TMC-1
Front
Terminal Short type — — TMC-1S TMC-1S TMC-1S TMC-1S
Type
Cover Long type — — TMC-2D TMC-2D TMC-2D TMC-2D
Rear Type BTC — — BTC-1 BTC-1 BTC-1 BTC-1
IEC Rail 35 mm ● ● ○ ○ ○ ○
Automatic Tripping Device Full Magnetic Full Magnetic Full Magnetic Full Magnetic Full Magnetic Full Magnetic
Trip Button — — — — — —

Attention
1. ● : Standard ○ : Option
2. Please use right and left poles in case of using ELBs of 3 poles 200V to 1ø2W 200V wiring sysytem.
3. Please connect neutral line to middle pole of ELBs incase of using ELBs of 3 poles 200V to 1ø3W100 / 200V distribution system.
4. Standard flush mounting base assembly of up to 400AF are GKW and GK is standard in case of 600AF or more.
5. Installation of phase separators is required in case of types marked (*2)
6. IEC rail is standard installation in case of EB-50E and EB-100E, so installation screws and metal fittings are not attached.
7. The accessories marked (*3) can be installed by customers
8. Please state frequency 50 or 60Hz in case of RF-800KN, RF-1000KN, RF-1200KN.

68
R ATINGS AND S PECIFICATIONS

EX100 EX100B EX225 EXK225 EX400 EX400B EX600B EX800B

3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W


1ø3W 1ø3W 1ø3W 1ø3W 1ø3W 1ø3W 1ø3W 1ø3W
1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W
3 3 3 3 3 3 3 3
200 – 440 200 – 440 200 – 440
100 – 200 200 – 440 200 – 440 200 – 440 200 – 440
(100 – 200) (100 – 200) (100 – 200)
200 / 225 / 250 300 / 350 / 400 400 / 450 / 500
125 150 175 125 150 175 250 300
50 60 75 100 50 60 75 100 300 / 350 / 400 500 / 600 600 / 700 / 800
200 225 200 225 350 400
adjustable adjustable adjustable
6 6 6 6 8 8 8 8
(15) 30 30 30 30 (30) (30)
100 ∙200 ∙500 100 ∙200 ∙500
100 (200) 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
— (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 )
— (0.3) (0.3 0.6 1.2) (0.3 0.6 1.2) (0.3 0.6 1.2) (0.3 0.6 1.2) (0.3 0.6 1.2) (0.3 0.6 1.2)

— (0.1) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5)

Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical


(button) (button) (button) (button) (button) (button) (button) (button)
— 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18
— 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18
— 10 / 3 15 / 8 15 / 8 36 / 18 36 / 18 36 / 18 36 / 18
— 35 / 9 35 / 18 35 / 18 50 / 25 50 / 25 50 / 25 50 / 25
10 / 3 35 / 9 35 / 18 35 / 18 50 / 25 50 / 25 50 / 25 50 / 25
10 / 3 — — — — — — —
75 75 105 105 140 140 210 210
130 130 165 165 257 257 274 274
60 60 60 68 103 103 103 103
84 84 85 93 133 133 141 141
0.8 0.9 2.2 2.2 6.6 6.5 10.6 12.9
Front Terminal Front Terminal Front Terminal Front Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
○ ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ (*3) ○ ○ (*3) ○ (*3) ○ (*3)
○ ○ ○ ○ (*3) ○ ○ (*3) ○ (*3) ○ (*3)
— — — — — — — —
○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○
STB-3K STB-3K
— — — — — —
(50A:STB-2M) (50A:STB-2M)
— — ○ ○ ○ ○ ○ ○
○ ○ — — — — — —
— — ○ ○ ○ ○ ○ (GK) ○ (GK)
— — — — — — — —

MIW-2E MIW-2E MIW-4F MIW-4L ○ MIW-5F MIW-5G MIW-5G


— — — — — — — —
— — — — — — — —
LC-2G LC-2G LC-4E LC-2F — — — —
HL-2G HL-2G HL-4E HL-2F HL-5 HL-5 HL-6 HL-6
HA-108 HA-108 HA-207 HA-209 HA-405 HA-406 HA-402 HA-402
HM-S12 HM-S12 HM-S22 HM-S23 — — — —
TMC-1 TMC-1 TMC-4K TMC-4J TMC-5B TMC-5B TMC-5D TMC-5D
TMC-1S TMC-1S TMC-4JS TMC-4JS — — — —
TMC-2D TMC-2D — — — — — —
BTC-1 BTC-1 BTC-4G BTC-4J BTC-5B BTC-5B — —
○ ○ — — — — — —
Full Magnetic Full Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Electric Relay Electric Relay Electric Relay
— — — ● — ● ● ●

9. Applicable voltage range


Rated voltage Applicable circuit voltage Permissible range of voltage
100 – 200V 100 ∙ 110 ∙ 200 ∙ 220V 80 – 242V
440V 400 ∙ 415 ∙ 440V 320 – 484V
200 ∙ 220 ∙ 240
200 – 440V 160 – 484V
380 ∙ 400 ∙ 415 ∙ 440V

69
Table 20 R series
Type RXK125-S RXK125-H RX100 RXK250-S RXK250-H RG-225BN RG-225BH RX400 RX400B

Appearance

3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W


Phase- wiring Sysytem 1ø3W 1ø3W 3ø4W 1ø3W 1ø3W 3ø4W 1ø3W 1ø3W
1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W
Number of poles 3 3 4 3 3 4 3 3
200 – 440
Rated Voltage (AC V) 200 – 440 200 – 440 200 – 440 200 – 440 200 – 440 200 – 440 200 – 440
(100 – 200)
200 / 225 / 250
Rated Current (A) 15 20 30 40 50 16 20 30 40 50 5 10 15 20 30 40 125 150 175 125 150 175 125 150 175 250 300
300 / 350 / 400
(Base ambient temperature 40ºC) 63 75 100 125 63 75 100 125 50 60 75 100 200 225 250 200 225 250 200 225 350 400
adjustable
Rated Impulse withstand Voltage Uimp (kV) 8 8 8 8 8 8 8 8
High 30 30 30 30 30 100 ∙200 (30) (30)
Rated Sensitivity Current (mA) 30
Speed 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500 100 ∙200 ∙500 ∙ 500 100 ∙200 ∙500 100 ∙200 ∙500
Type Operating time (sec. or less) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
Rated Sensitivity Current (mA) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100∙200∙500 ) — (100 ∙200 ∙500 ) (100 ∙200 ∙500 )
Time
Operating time (sec. or less) (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2) — (0.3 ∙ 0.6 ∙1.2) (0.3 ∙ 0.6 ∙1.2)
Delay
Type Limiting non-actuating time
(0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) (0.1 0.2 0.5) — (0.1 0.2 0.5) (0.1 0.2 0.5)
(sec. or more)
Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical
Indication of Earth Leakage
(button) (button) (button) (button) (button) (button) (button) (button)
440V 30 / 15 50 / 25 50 / 25 30 / 15 50 / 25 42 / 21 50 / 50 50 / 50
415V 30 / 15 50 / 25 50 / 25 30 / 15 50 / 25 42 / 21 50 / 50 50 / 50
Rated JIS C 8201-2-2 400V 30 / 15 50 / 25 50 / 25 30 / 15 50 / 25 42 / 21 50 / 50 50 / 50
Breaking Ann2 AC
Capacity (kA) (Icu/Ics) 240V 50 / 25 100 / 50 85 / 43 50 / 25 100 / 50 85 / 43 100 / 100 100 / 100
200V 50 / 25 100 / 50 85 / 43 50 / 25 100 / 50 85 / 43 100 / 100 100 / 100
100V — — — — — — — —
a d
c a 90 90 120 105 105 185 140 140
b 150 150 150 165 165 345 275 275
Dimensions (mm)
c 68 68 103 68 68 103 103 103
b

d 94 94 123 95 95 133 133 133


Net Weight (kg) 2.1 2.1 2.8 2.0 2.0 9.3 6.6 6.6
Standard Connection Type Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Terminal Front Bar Terminal Front Bar Terminal
Phase Separator for Line Side ● (*2) ● (*2) ○ ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
Test Button Lead Wire TBL ○ ○ ○ ○ ○ ○ ○ ○
Alarm Switch AL ○ (*3) ○ (*3) ○ ○ (*3) ○ (*3) ○ ○ ○ (*3)
Interior Auxiliary Switch AUX ○ (*3) ○ (*3) ○ ○ (*3) ○ (*3) ○ ○ ○ (*3)
Accessories Earth Leakage Alarm Sw. EAL — — — — — — — —
TB ○ ○ ○ ○ ○ ○ ○ ○
Terminal Block
TB2 ○ ○ ○ ○ ○ — ○ ○
STB-2S STB-2S
STB ○ — — — — —
(Up to 50A) (Up to 50A)
Rear-connecting Stud
BSD-3S BSD-3S
BSD — ○ ○ ○ ○ ○
(60A or more) (60A or more)
Flush Mounting Base GKW (STB) ○ (Up to 50A) ○ (Up to 50A) ○ — — — — —
Assembly GK∙GKW (BSD) ○ (60A or more) ○ (60A or more) — ○ ○ ○ (GK) ○ ○
Plug-in Mounting
PK ○ ○ — — — — — —
Base Assembly
Mechanical Interlock MIW MIW-3H MIW-3H MIW-3F MIW-4M MIW-4M MIW-5DE ○ MIW-5F
Motor-operating MMK-S — — — — — — — —
Exterior
Accessories Mechanism MMK-C — — — — — — — —
Lock Cover LC ○ ○ LC-2C LC-4J LC-4J — — —
Handle Lock HL ○ ○ ○ HL-4J HL-4J HL-5 HL-5 HL-5
Handle Operating HA — — HA-106 HA-210 HA-210 HA-405 HA-405 HA-406
Mechanism HM HM-S13 HM-S13 HM-S11 HM-S25 HM-S25 — — —
TMC TMC-2C TMC-2C TMC-3C TMC-4J TMC-4J TMC-5B TMC-5B TMC-5B
Front
Terminal Short type — — — TMC-4JS TMC-4JS — — —
Type
Cover Long type — — — — — — — —
Rear Type BTC BTC-2C BTC-2C BTC-3C BTC-4J BTC-4J BTC-5B BTC-5B BTC-5B
IEC Rail 35 mm — — — — — — — —
Thermal- Thermal- Thermal- Thermal- Thermal- Electronic
Automatic Tripping Device Full Magnetic Thermal-Magnetic
Magnetic Magnetic Magnetic Magnetic Magnetic Relay
Trip Button ● ● — ● ● — — ●

Attention
1. ● : Standard ○ : Option
2. Please use right and left poles in case of using ELBs of 3 poles 200V to 1ø2W 200V wiring sysytem.
3. Please connect neutral line to middle pole of ELBs incase of using ELBs of 3 poles 200V to 1ø3W100 / 200V distribution system.
4. Standard flush mounting base assembly of up to 400AF are GKW and GK is standard in case of 600AF or more.
5. Installation of phase separators is required in case of types marked (*2)
6. IEC rail is standard installation in case of EB-50E and EB-100E, so installation screws and metal fittings are not attached.
7. The accessories marked (*3) can be installed by customers
8. Please state frequency 50 or 60Hz in case of RF-800KN, RF-1000KN, RF-1200KN.

70
R ATINGS AND S PECIFICATIONS

RG-400BN RG-400BH RX600B RF-600FN RX800B RF-800KN RF-1000KN RF-1000CBN RF-1200KN RF-1200CBN

3ø3W 3ø3W 3ø3W 3ø3W 3ø3W 3ø3W


3ø4W 1ø3W 3ø4W 1ø3W 3ø4W 1ø3W 3ø4W 1ø3W 1ø3W 3ø4W 1ø3W
1ø2W 1ø2W 1ø2W 1ø2W 1ø2W 1ø2W
4 3 4 3 4 3 4 3 3 4 3

200 – 440 200 – 440 440 (200) 200 – 440 440 (200) 440 (200) 440 (200) 440 (200) 440 (200)

300 / 350 / 400 400 / 450 / 500 500 / 600 / 700 600 / 700 / 800
250 300
500 / 600 500 600 600 / 700 / 800 700 800 1000 800 / 900 / 1000 1200 1000 / 1200
350 400
adjustable adjustable adjustable adjustable
8 8 8 8 8 8 8 8 8
50 ∙100 ∙200 50 ∙100 ∙200 50 ∙100 ∙200 50 ∙100 ∙200 50 ∙100 ∙200 50 ∙100 ∙200
100 ∙200 ∙500 30 100 ∙200 ∙500 100 ∙200 ∙500
500 ∙1000 500 ∙1000 500 ∙1000 500 ∙1000 500 ∙1000 500 ∙1000
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
(100 ∙200 ∙500 ) — (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 ) (100 ∙200 ∙500 )
(0.3 0.6 1.2) — (0.3 0.6 1.2) (0.3 1.2) (0.3 0.6 1.2) (0.3 1.2) (0.3 1.2) (0.5 1.2) (0.3 1.2) (0.5 1.2)

(0.1 0.2 0.5) — (0.1 0.2 0.5) (0.1 0.5) (0.1 0.2 0.5) (0.1 0.5) (0.1 0.5) (0.2 0.5) (0.1 0.5) (0.2 0.5)

Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical


(button) (button) (button) (button) (button) (button) (button) (button) (button)
42 / 21 50 / 50 42 / 21 50 / 50 85 / 22 85 / 22 85 / 22 85 / 22 85 / 22
42 / 21 50 / 50 42 / 21 50 / 50 85 / 22 85 / 22 85 / 22 85 / 22 85 / 22
42 / 21 50 / 50 42 / 21 50 / 50 85 / 22 85 / 22 85 / 22 85 / 22 85 / 22
85 / 43 100 / 100 85 / 43 100 / 100 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
85 / 43 100 / 100 85 / 43 100 / 100 125 / 32 125 / 32 125 / 32 125 / 32 125 / 32
— — — — — — — — —
185 210 280 210 280 210 280 210 210 280 210
345 274 580 274 800 800 800 800 800
103 103 141 103 185 185 185 185 185
133 141 179 141 225 225 225 225 225
10.2 10.6 23.0 12.9 50.0 41.0 60.0 41.0 41.0 60.0 41.0
Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ (*3) ○ ○ (*3) ○ ○ ○ (*3) ○ ○ (*3)
○ ○ (*3) ○ ○ (*3) ○ ○ ○ (*3) ○ ○ (*3)
— — ● — ● ● ● ● ●
○ ○ ○ ○ ○ ○ ○ ○ ○
— ○ ○ ○ ○ ○ ○ ○ ○
— — — — — — — — —

○ ○ ○ ○ ○ ○ ○ ○ ○
— — — — — — — — —
○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK)
— — — — — — — — —

MIW-5DE MIW-5G ○ MIW-5G ○ ○ ○ ○ ○


— — — — — — — — —
— — — — — — — — —
— — — — — — — — —
HL-5 HL-6 HL-6 HL-6 ○ ○ ○ ○ ○
HA-405 HA-402 HA-402 HA-402 HA-801 HA-801 HA-801 HA-801 HA-801
— — — — — — — — —
TMC-5B TMC-5D TMC-5D TMC-5D TMC-6 TMC-6 TMC-6B TMC-6 TMC-6B
— — — — — — — — —
— — — — — — — — —
BTC-5B — — — — — — — —
— — — — — — — — —
Thermal- Thermal- Thermal- Thermal-
Thermal-Magnetic Electronic Relay Electronic Relay Electronic Relay Electronic Relay
Magnetic Magnetic Magnetic Magnetic
— — ● ● ● ● ● ● ● ●

9. Applicable voltage range


Rated voltage Applicable circuit voltage Permissible range of voltage
100 – 200V 100 ∙ 110 ∙ 200 ∙ 220V 80 – 242V
200V 200 ∙ 220V 160 – 220V
440V 400 ∙ 415 ∙ 440V 320 – 484V
200 ∙ 220 ∙ 240
200 – 440V 160 – 484V
380 ∙ 400 ∙ 415 ∙ 440V

71
C ONSTRUCTION

The Earth Leakage Circuit Breakers (ELB) consists of circuit breaker unit composed by a switching mechanism, are
extinguishers, an over-current tripping device, etc., zero-phase sequence current transformer, amplifier and others for
detecting earth leakage current. These components are accommodated in a heat-proof and arc-proof molded case and
cover. A typical example of its construction is shown in the diagram below.

Handle Arc extinguishing device

Earth leakage tripping device


Quick-make, quick-break,
trip-free mechanism
Earth leakage trip indicator

Test button
Amplifier

Over current tripping device Rated sensitivity current selector

Zero-phase sequence Operating time selector


current transformer (Time delay type)

Typical construction of Earth leakage breaker for power supply

Rated sensitivity Connecting


current selector terminal for ZCT

ZCT Connecting
terminal

Operating
time selector

Reset button

Connecting terminal for Earth leakage Test button Output terminal


earth leakage relay trip indication

Typical construction of Earth leakage relays

72
Table 21 Applicability of interior accessories

EX30 EX225
RF-800KN
EX50 ✶ EXK225 ✶ EX600B
RG-225B (N) RF-1000KN
EB-50E EX50B ✶ RXK125-S ✶ RX600B
Frame EB-50E ✶ EX400B RF-1200KN RF-600FN
EB-100E EX50C ✶ RXK125-H ✶ EX800B
✶ RX400B ✶ RF1000CBN
EX100 ✶ RXK250-S ✶ RX800B
✶ RF1200CBN
Poles EX100B ✶ RXK250-H

Accessories 2 3 3 3, 4 3 3, 4 3

Alarm
AL 1C 1C 1C 2C 2C 2C 2C
Switch

Auxiliary
AUX 1C 1C 1C 2C 2C 2C 2C
Switch

Alarm AL 1C 1C 2C 1C 1C 1C
+ + —
Auxiliary AUX 1C 1C 2C 2C 2C 2C

Earth
Leakage
EAL — — — — —
Alarm
Switch Equipped normaly Equipped normaly

Alarm AL 1C 1C
+ + 2C 2C
Auxiliary AUX — — — — —
+ +
EAL Switch EAL Equipped normaly Equipped normaly

Test Button
TBL
Lead Wire

Remarks: (1) Handle of breaker


(2) 2C: 1C is also available Handle of Breaker AL EAL AUX TBL

Table 22 Earth Leakage Relays


Standard type
Function Automatic Reset Relay: Automatic Reset
High Speed Type Time Delay Type Latched Type
Type Lamp: Latched
Type-Form R-NZB R-NZBT R-NZBK R-NZBL R-NZBR

Appearance

Rated Voltage (AC V) 100, 200, 240, 380, 415


Frequency (Hz) 50, 60
50 / 100 / 200 / 100 / 200 / 500 / 50 / 100 / 200 / 100 / 200 / 500 /
Rated Sensitivity Current (mA)
500 / 1000 (1) (30) 1000 / 2000(1) 500 / 1000 (1) (30) 1000 / 2000(1)
0.3 0.1 or less 0.3
Operating Time (sec.) 0.1 or less
(0.2 / 0.5 / 2 / 4 (1)) 0.3 (0.2 / 0.5 / 2 / 4 (1))
Alarm Contact 1c + 1a
a 80
a d
c

Dimensions (mm) b 80
b

c 115
Weight (kg) 0.45
Notes: (1) Interchangeable by manual operation.
(2) Rating with ( ) are manufactured by customer’s order.
(3) Rated Voltage Applicable Circuit Voltage Remarks
100V 100 ∙ 110V Interchangealbe by
200V 200 ∙ 220V tap changing
240V 230 ∙ 240V
380V 380V
415V 400 ∙ 415 ∙ 440 ∙ 460V (60Hz)

73
Table 23 Contact Specifications
Load Resistive Load cosø = 1 Inductive Load cosø = 0.3, L / R = 7ms
Rated Thermal Current (A) 3
AC 120V 3 2
AC 240V 3 1.5
Rated Current (A) AC 415V 1 0.5
DC 24V 3 1.5
DC 100V 0.2 0.2

Table 24 Zero-phase-sequence Current Transformer


Maximum Available Wire Size
Aperture
Type Vinyl-insulated 600V Wire (IV) Polyethylene-Insulated 600V Wire (CV)
Diameter
2-wire 3-wire 4-wire 2-wire 3-wire 4-wire
ZR-15 ø15 14mm2 (88A) 8mm2 (61A) 8mm2 (61A) 2mm2 (33A) 2mm2 (33A) —
ZR-30B ø30 60mm2 (217A) 50mm2 (190A) 38mm2 (162A) 38mm2 (190A) 22mm2 (135A) 14mm2 (105A)
ZR-58B ø58 250mm2 (556A) 200mm2 (469A) 150mm2 (395A) 200mm2 (560A) 150mm2 (480A) 100mm2 (365A)
2 2 2 2 2
ZR-65 ø65 325mm (650A) 250mm (556A) 200mm (469A) 250mm (655A) 200mm (560A) 150mm2 (480A)
ZR-80 ø80 500mm2 (842A) 500mm2 (842A) 325mm2 (650A) 400mm2 (870A) 325mm2 (760A) 250mm2 (655A)
ZR-100 ø100 500mm2 x 4 (1,684A) 400mm2 x 6 (1,490A) 500mm2 (842A) 600mm2 (1,140A) 600mm2 (1,140A) 400mm2 (870A)
2 2 2 2
ZR-120 ø120 — 350mm x 9 (1,950A) 400mm x 8 (1,490A) 1000mm (1,600A) 800mm (1,370A) 600mm2 (1,140A)

Table 25 ZCT with Primary Conductors


Type Z-400B Z-600B Z-800B Z-1000B Z-1200B Z-2000B

Appearance

Number of Poles 3 4 3 4 3 4 3 4 3 4 3 4
Continuous Thermal Current (A) 400 600 800 1000 1200 2000
Rated Voltage (AC V) 600
Frequency (Hz) 50, 60
Rated withstand Current (kA) 100 (peak value) 150 (peak value)
Rated Sensitivity Current Refer to Earth Leakage Relays
Operating Time (sec.) Ditto
A 220 315 220 315 240 320 240 320 240 320 310 380
a c
B 348 348 348 348 380 380 380 380 380 380 300 300
Dimensions (mm)
b1

B1 400 400 460 460 480 480 480 480 480 480 600 600
b

C 187 214 187 214 214 239 214 239 214 239 242 284
Weight (kg) 11 15 11.2 16 12.3 17 12.3 17 13 18 30 42

74
A PPLICATION OF E ARTH L EAKAGE R ELAYS

75
DIMENSIONS

Hr.
EB-50E

Min.
Max.

Tripping Time
Base ambient
Min.
temperature 40ºC

Sec.

Tripping Time (%)


Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Mounting fixture 2-M4 mounting hole 2-M4 mounting hole


M5 screw

Test button

Earthleakage Earthleakage
trip indicator trip indicator

Test button

Direct-connected bus drilling

■ Drilling Plan 2-M4 screw hole 2-M4 screw hole


or ø5 hole or ø5 hole

1mm clearance on each side of handle


2 pole 3 pole

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector: Applicable wire
14mm2 conductor
ø1.6 – 22mm2

M5 screw

Bus or pressure-type wire connector connection Wire connection

76
Hr.
EX30 / EX50 / EX50B Max. value for 31A or more

Min.
Max. value for
30A or less

Tripping Time
Base ambient
temperature 40ºC

Min.
value

Tripping Time (%)


Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
2-mounting holes for
M4 screw

Rated sensitivity
current selector
(if provided)

ø5.5 holes
Earthleakage
trip indicator

Test button

Direct-connected bus drilling

■ Drilling Plan 2-M4 tap holes


or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection


Max. applicable
pressure-type
wire connector:
14mm2

Applicable wire
conductor
ø1.6 – 22mm2

M5 screw

77
Hr.
EX50C Max. value for 31A or more

Min.
Max. value for
30A or less

Tripping Time
Base ambient
temperature 40ºC

Min.

Tripping Time (%)


value

Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
2-mounting holes for
M4 screw Phase separator

Rated sensitivity
current selector
(if provided)

Earth leakage
indicator

Test button

Direct-connected bus drilling

■ Drilling Plan
2-M4 tap holes
or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection


Max. applicable
pressure-type
wire connector:
14mm2
Applicable wire
conductor
M5 screw ø1.6 – 22mm2

78
EB-100E

Hr.
Max.

Min.
Tripping Time
Min. Base ambient
temperature 40ºC

Tripping Time (%)


Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Mounting fixture 2-mounting hole


M8 screw

ø5.5 holes

Test button

Earthleakage
trip indicator

Direct-connected bus drilling

■ Drilling Plan
2-M4 screw hole
or ø5 hole

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector:
38mm2

M8 screw

79
EX100

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC

Min. value

Tripping Time (%)


Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Mounting hole
for M4 screw

Earth leakage
indicator

Test button

Direct-connected bus drilling

■ Drilling Plan
2-M4 tap holes
or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector:
38mm2 Applicable wire
M8 screw conductor
ø1.6 – 22mm2

80
EX100B

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC

Min. value

Tripping Time (%)


Sec.
Current Ambient Temperture (ºC)
(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Mounting hole
for M4 screw

Earthleakage
trip indicator

Test button

Direct-connected bus drilling

■ Drilling Plan
2-M4 tap holes
or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector:
38mm2 Applicable wire
M8 screw conductor
ø1.6 – 22mm2

81
Hr.

Hr.
RXK125-S / RXK125-H
Max. value of 51 to 125A

Min.

Min.
Max. value of 31 to 50A

Max. value

Tripping Time

Tripping Time
Max.
interrupting Min. value Max.
time interrupting

Sec.

Sec.
Min. value time

Current Current
(percent rated current) (percent rated current)

Overcurrent Tripping Overcurrent Tripping


Characteristic Curve Characteristic Curve
(15-30A) (31-125A)

■ Dimensions
Phase insulator
(Removable)

2-M4 mounting holes

Test button

Rated sensitivity
current selector
(if provided)

Operating time selector


(Time delay type only)

Earth leakage
trip indicator Trip button

Direct-connected bus drilling

■ Drilling Plan
2-M4 screw holes or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable pressure-type


wire connector: 60mm2
(22mm2 for 50A or less)
M8 screw
(M6 screw for 24
50A or less) 9.5
17

Bus or pressure wire conductor connection


Applicable wire
conductor
( ): dimensions only for 50A or less
ø1.6 – 22mm2

Wire connection (15 to 50A)

82
EX225

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Mounting hole
Phase separator for M4 screw

Earthleakage
indicator

Rated sensitivity
current selector
(if provided)

Test button

Direct-connected bus drilling

■ Drilling Plan

4 (or 2)-M4 tap


holes or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Maximum applicable pressure


-type wire connector = 60mm2
Special pressure type wire
connector is attached for
175 – 225A as shown on the
right table
Rated current (A) Applicable wire size of pressure-
type wire connector (mm2)
175 – 225 Pressure-type wire connector
80, 100, 125 (mm)

Pressure-type wire connector


directly connected

83
EXK225

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Phase separator

Rated sensitivity
current selector
(if provided)
Trip
button
Test button
Operating time
selector

Earthleakage
trip indicator

2-M4 mounting hole

Direct-connected bus drilling

■ Drilling Plan

2-M4 screw hole


or ø5 hole

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector:
150mm2

M8 screw

Pressure-type wire connector


directly connected

84
RXK250-S / RXK250-H

Hr.
Max. value

Min.
Tripping Time
Base ambient
temperature 40ºC
Min. value

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Mounting hole for
M4 screw

Earthleakage
trip indicator
Rated sensitivity
current selector
(if provided)

Operating time selector


(Time delay type only)

Test button

Direct-connected bus drilling

■ Drilling Plan

4-M4 tap holes


or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Maximum applicable pressure


t-ype wire connector = 60mm2
Special pressure type wire
connector is attached for
175 – 225A as shown on the
right table
Rated current (A) Applicable wire size of pressure-
type wire connector (mm2)
175 – 225 Pressure-type wire connector
80, 100, 125 (mm)

Pressure type wire connector


directly connected

85
EX400 / RX400

Hr.
Max. value

Min.
Base ambient

Tripping Time
Min. value temperature 40ºC

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

Phase separator
Mounting hole for M4 screw
Rated sensitivity
current selector
(if provided)

Earthleakage indicator
Operating time selector
(Time delay type only)
Test button

■ Drilling Plan

4-M4 tap holes


or ø5 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M10 bolt

86
EX400B / RX400B

Hr.
Min.
Tripping Time
Max.

Sec.
interrupting
time

200A setting
Current
400A setting
(percent rated current)

Overcurrent Tripping Characteristic Curve

■ Dimensions

Phase separator Phase separator

4-M6 mounting hole 4-M6 mounting hole

Rated
Rated sensitivity sensitivity
current selector current
selector
Operating
time
Operating time
selector
selector
Earth
leakage
Earth leakage indicator
indicator
Test
Test button button

Rated current
Rated current selector
selector Trip button
Trip button

■ Drilling Plan
4-M6 screw hole
or ø7 hole

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement

M10 bolt

87
Hr.
EX600B / RX600B

Min.
Tripping Time
Max.

Sec.
interrupting
time

Current 300A setting


(percent rated current) 600A setting

Overcurrent Tripping
Characteristic Curve

■ Dimensions
4-M6 mounting hole Phase separator

Test button

Rated sensitivity
current selector

Operating time
selector

Earth leakage
indicator

Rated current selector

Trip button

■ Drilling Plan
4-M6 screw hole
or ø7 hole

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement

M12 bolt

88
Hr.
EX800B / RX800B

Min.
Tripping Time
Max.

Sec.
interrupting
time

Current 400A setting


(percent rated current) 800A setting

Overcurrent Tripping
Characteristic Curve

■ Dimensions
Phase separator
4-M6 mounting hole

Test button

Rated sensitivity
current selector

Operating time
selector

Earth leakage
indicator

Rated current selector

Trip button

■ Drilling Plan
4-M6 screw hole
or ø7 hole

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement

M12 bolt

89
Hr.
RF-1000KN
Max. value

Min.
Adjustable
magnetic
trip range
Min. (in 4 steps)
value

Tripping Time
Base ambient
temperature 40ºC
Position
of setting

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

4-M10 tap holes or ø11 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

90
Hr.
RF-1000CBN

Min.
Tripping Time
Max.

Sec.
interrupting
time
1000A setting
(time highly type)

500A setting (time highly type)

500A setting (time delay type)


Current
(percent rated current) 1000A setting (time delay type)

Overcurrent Tripping
Characteristic Curve

■ Dimensions
Phase separator

M10 mounting hole ø13.5 holes


Auxiliary handle

Trip button

Rated current
selector

Sealed cover
Rated sensitivity
current selector

Test button
Earth leakage indicator
and reset button

■ Drilling Plan

4-M10 screw hole or ø11 hole

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

91
Hr.
RF-1200KN
Max. value

Min.
Adjustable
magnetic
trip range
Min. (in 4 steps)
value

Tripping Time
Base ambient
temperature 40ºC
Position
of setting

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

4-M10 tap holes or ø11 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

92
Hr.
RF-1200CBN

Min.
Tripping Time
Max.

Sec.
interrupting
time
1200A setting
(time highly type)

600A setting (time highly type)

600A setting (time delay type)


Current
(percent rated current) 1200A setting (time delay type)

Overcurrent Tripping
Characteristic Curve

■ Dimensions
Phase separator

M10 mounting hole ø13.5 holes


Auxiliary handle

Trip button

Rated current
selector

Sealed cover
Rated sensitivity
current selector

Test button
Earth leakage indicator
and reset button

■ Drilling Plan
4-M10 screw hole or ø11 hole

1mm clearance on each side of handle


For front mounting bolts
Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

93
Hr.
RX100 4P Max. value for 31 to 100A

Min.
Max. value for
30A or less

Tripping Time
Base ambient
Min. temperature 40ºC
value
for 31 to
100A
Min.

Tripping Time (%)


Sec.
value
for 30A
or less

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions Mounting hole for


M4 screw

Phase separator

Rated sensitivity
current selector ø8.5 hole
(if provided) (ø6.5 hole for 50A or less)

Test button

Earth leakage
trip indicator

Direct-connected bus drilling

■ Drilling Plan
4-M4 tap holes
or ø5 holes

Center of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable pressure-type


wire connector: 38mm2
(22mm2 for 50A or less)

M8 screw
(M6 screw for Applicable wire
50A or less) conductor
ø1.6 – 22mm2

94
Hr.
RG-225BH 4P Max. value

Min.
RG-225BN 4P

Tripping Time
Base ambient
Min. value temperature 40ºC

of rated current (%)


Compensation rate
Sec.
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Phase separator

4-Mounting hole for M6 screw

Earth leakage
trip indicator Test button

ø5.5 holes

Rated sensitivity
current selector

Direct-connected bus drilling

■ Drilling Plan
4-M6 tap holes
or ø7 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

Max. applicable
pressure-type
wire connector:
100mm2

M10

Bus or pressure-type wire connector connection

95
Hr.
RG-400BN 4P Max. value

Min.
RG-400BH 4P

Tripping Time
Min. Base ambient
value temperature 40ºC

Sec.

of rated current (%)


Compensation rate
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Phase separator

Mounting hole for M6 screw


S.N pole
R.T pole

Test button
Earth leakage
trip indicator

Rated sensitivity
current selector

ø11 holes

■ Drilling Plan

4-M6 tap holes or ø4-7 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M10 bolt

96
RF-600FN 4P

Hr.
Max. value

Min.
Adjustable
Min. magnetic
value trip range

Tripping Time
(in 4 steps)
Base ambient
temperature 40ºC
Position
of setting

Sec.

of rated current (%)


Compensation rate
Max. interrupting time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
Phase separator
4-mounting holes for M8 screw
ø13.5 holes

Trip button Rated sensitivity


current selector
Reset buton and
earth leakage
trip indicator

Test button

■ Drilling Plan
4-M8 tap holes or ø9 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

97
Hr.
RF-800KN 4P
Max. value

Min.
Adjustable
magnetic
trip range
(in 4 steps)
Min.

Tripping Time
value
Base ambient
Position temperature 40ºC
of setting

of rated current (%)


Sec.

Compensation rate
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions

■ Drilling Plan

4-M10 tap holes or ø4-11 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

98
Hr.
RF-1000KN 4P
Max. value

Min.
Adjustable

RF-1200KN 4P
magnetic
trip range
Min. (in 4 steps)
value

Tripping Time
Base ambient
temperature 40ºC
Position
of setting

of rated current (%)


Sec.

Compensation rate
Max.
interrupting
time

Current Ambient Temperture (ºC)


(percent rated current)

Overcurrent Tripping Temperature


Characteristic Curve Compensation Curve

■ Dimensions
68.5
t15

■ Drilling Plan

4-M10 tap holes or ø4-11 holes

1mm clearance on each side of handle

For front mounting bolts Frontplate cutout

■ Terminal Arrangement ■ Internal Diagram Connection

M12 bolt

99
Rated sensitivity
■ Dimensions Mounting holes current selector

R-NZB

Terminal screw for M3.5


Indication lamp Test button Reset button

■ Drilling Plan ■ Internal Diagram Connection

2-M4 tap holes or ø2-5 holes

Rated sensitivity
■ Dimensions Mounting holes current selector

R-NZBT Operating time


selector

Terminal screw for M3.5


Indication lamp Test button Reset button

■ Drilling Plan ■ Internal Diagram Connection

2-M4 tap holes or ø2-5 holes

100
Rated sensitivity
■ Dimensions Mounting holes current selector

R-NZBK Operating time


selector

Terminal screw for M3.5


Indication lamp Test button

■ Drilling Plan ■ Internal Diagram Connection

2-M4 tap holes or ø2-5 holes

Rated sensitivity
■ Dimensions Mounting holes current selector

R-NZBL

Terminal screw for M3.5


Test button Indication lamp
Reset button

■ Drilling Plan ■ Internal Diagram Connection

2-M4 tap holes or ø2-5 holes

101
Rated sensitivity
■ Dimensions Mounting holes current selector

R-NZBR Operating time selector

Terminal screw for M3.5


Indication lamp Test button Reset button

■ Drilling Plan ■ Internal Diagram Connection

2-M4 tap holes or ø2-5 holes

102
■ Dimensions ■ Drilling Plan

Z-400B
Terminal
screw for
M3.5

ø13.5
holes 4-M6 tap holes 4-M6 tap holes
or ø4-8 holes or ø4-8 holes
3 pole 3 pole 4 pole

Terminal ■ Terminal Arrangement


screw for
M3.5

M12 bolt

ø13.5
holes

4 pole

■ Dimensions ■ Drilling Plan

Z-600B
Terminal
screw for
M3.5

ø13.5
holes 4-M6 tap holes 4-M6 tap holes
or ø4-8 holes or ø4-8 holes
3 pole 3 pole 4 pole

Terminal ■ Terminal Arrangement


screw for
M3.5

M12 bolt

ø13.5
holes

4 pole

■ Dimensions ■ Drilling Plan

Z-800B Terminal
screw for
M3.5

ø13.5
holes
4-M8 tap 4-M8 tap
holes or holes or
3 pole 3 pole ø4-10 holes 4 pole ø4-10 holes

Terminal ■ Terminal Arrangement


screw for
M3.5

M12 bolt

ø13.5
holes

4 pole

103
■ Dimensions ■ Drilling Plan

Z-1000B Terminal
screw for
M3.5

ø13.5
holes
4-M8 tap 4-M8 tap
holes or holes or
3 pole 3 pole ø4-10 holes 4 pole ø4-10 holes

Terminal ■ Terminal Arrangement


screw for
M3.5

M12 bolt

ø13.5
holes

4 pole

■ Dimensions ■ Drilling Plan

Z-1200B Terminal
screw for
M3.5

ø13.5
holes
4-M8 tap 4-M8 tap
holes or holes or
3 pole 3 pole ø4-10 holes 4 pole ø4-10 holes

Terminal ■ Terminal Arrangement


screw for
M3.5

M12 bolt

ø13.5
holes

4 pole

■ Dimensions ■ Drilling Plan

Z-2000B
Terminal
screw for
M3.5

ø4-11 holes
4-M8 tap 4-M8 tap
holes or holes or
ø4-12 ø4-12
3 pole 3 pole holes 4 pole holes
Terminal
screw for
M3.5
■ Terminal Arrangement

M10 bolt

ø11 holes

4 pole

104
ZR-15 — 120

■ Dimensions
2-M4 mounting holes Mounting holes Surface K Mounting holes

Surface L

Output terminal (M3.5)

ø15 holes
ø30 holes

Outlet terminal wire 0.5mm2


length 500mm

ZR-15 ZR-30B

Mounting holes Surface K Mounting holes

Surface L

4-øH holes

Output terminal (M3.5) Output terminal (M3.5)

ø58 holes
s
le
ho
øD

ZR-58B ZR-65 — 120

Type A B C D E F×G H J (kg)


ZR-65 145 170 79 Ø65 75 80 × 60 Ø6 6 1.6
ZR-80 172 198 89 Ø80 90 100 × 65 Ø6 6 2.0
ZR-100 185 222 90 Ø100 100 110 × 65 Ø8 8 2.5
ZR-120 226 264 95 Ø120 120 140 × 70 Ø9.5 9.5 3.0

105
E ARTH L EAKAGE BREAKERS FOR WELDERS

Hr.
Min.

Tripping Time (sec.)


Tripping Time
Max. value

Max. value

Sec.
Setting
time (sec.)

Min. value Min. value

Continuous Tripping Instantaneous


Current (A) Current Tripping Current (A)
RXW225 Earth Leakage Current
(Percent Rated Sensitivity Current)

Overcurrent Tripping Earth Leakage Tripping


Characteristic Curve Characteristic Curve (at 0.3 sec.)

■ Ratings and Specifications


Type RXW225 RGW-400B
Number of Poles 2
Rated Voltage (AC V) 200, 415
Rated Sensitivity Current (mA) 100 ∙ 200 ∙ 500*
Operating Time (sec.) **0.3 ∙ 0.6 ∙ 1.2* (0.1 ∙ 0.2)*
Rated Current (kA) 225 400
Instantaneous Tripping Current (kA) 3—4 3.6 — 4.4

Interrupting Capacity AC200V 85


(kA) sym. AC415V 42
Setting Current (A) 3±1
Continuous
Current Setting Time (sec.) **0.3 ∙ 0.6 ∙ 1.2(3)*
Protection
Release Time (sec.) 0.1
Terminal For pressure-type wire connector terminal Front bar terminal
Net Weight (kg) 7.4 8.3
Note:
* Interchangeable by manual operation.
** Earth leakage tripping time and continuous current tripping time are interlocked.

■ Selection
Specifications of Welder Setting Current
Rated Current of ELCB (A) of Instantaneous
Rated Voltage (AC V) Rated Capacity (kVA) Maximum Input (typ.)(kVA) Tripping Current (A)
35 111 225 1200
50 106 225 1200
200
75 219 400 2250
100 330 400 3500
35 111 225 600
50 106 225 600
75 219 225 1200
415 100 330 225 1700
125 (395) 400 2250
150 (475) 400 2500
200 (630) 400 3500
( ): for reference value

106
■ Dimensions

RXW225
4-M4 mounting hole
Earth leakage indicator M8 screw

Indication lamp

Test button

Rated sensitivity
current selector
Operation time selector

■ Drilling Plan 4-M4 mounting holes


or ø5 holes

■ Dimensions Insulting barrier

RGW-400B
easy installation
ø11 holes
4-mounting hole for M6 screw

Continuous
currrnt and
earth leakage Test button
indicator

Rated operation time selector Rated sensitivity


current selector

■ Drilling Plan
M6 tap holes or ø7 holes

107
MINIATURE CIRCUIT BREAKERS
MCB is applicable to electric circuit with rated voltage 230/400V, 240/415V AC,
frequency 50/60Hz and rated current is up to 63A.
The product provides against overload and short circuit and equipments in
household and commercial installations.
MCB is also used as non-frequent changeover of electric circuit.

BK63 series BTK63 series Alarm switch Auxiliary switch


(for BK63)

TRIPPING CHARACTERISTICS COLORED HANDLES


n Type B Easy to distinguish the rated current of the MCB by means of
Instant tripping characteristics : 3–5In colored handle.
Application : computers and electronic equipments
1A Black
n Type C
I nstant tripping characteristics : 5–10In 2A Pink
Application : general load such as bulbs , motors
3A Pink

n Type D 4A Brown
Instant tripping characteristics : 10–20In 6A Green
Application : high current surge device such as transformers, motors
with heavy load
10A Red
16A Grey
20A Blue
APPROVAL 25A Yellow
32A Purple
n CE marking 40A Black

n CB Certificate 50A White


63A Cupper-colored

108
SPECIFICATIONS

Type BK63 BTK63

Protection Overload and short circuit

Rated current 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A

Characteristics B, C, D curve

Number of poles 1P, 1P+N, 2P, 3P, 3P+N, 4P

1P 2, 3, 4P 1P 2, 3, 4P
Breaking capacity 10kA
6kA 6kA 10kA
at 230/400VAC at 400VAC at 240/415VAC at 415VAC
Standards IEC60898

Approval SEMKO CB scheme KEMA CB scheme

Type of trip Thermal magnetic release

Electrical endurance 6,000 operations 8,000 operations

Installation 35mm DIN rail

Width 17.8mm per pole

Type of terminal Lug type (Cable up to 25mm2)

1changeover contact
6A at 230VAC,3A at 415VAC(AX)
6A at 230VAC,3A at 415VAC(AL)
Alarm switch 2A at 48VAC,1A at 125VAC
Not applicable
(Optional)
Lug terminal
Cable capacity 2.5mm2

9mm wide

(mm) (mm)

Dimension

109
C HARACTERISTIC CURVE AND C OMPENSATION CURVE

n Characteristic curve For type BK63, BTK63


Operating curves

n Compensation table n Compensation curve

[Temperature copensation table](IEC60898-1)


In(A)
1 1.05 1.02 1.0 0.98 0.95 0.93 0.9 0.89 0.85
2 2.03 2.04 2.0 1.96 1.92 1.88 1.84 1.8 1.74
3 3.18 3.09 3.0 2.91 2.82 2.7 2.61 2.49 2.37
4 4.24 4.12 4.0 3.88 3.75 3.64 3.52 3.36 3.24
6 5.24 6.12 6.0 5.88 5.76 5.64 5.52 5.4 5.3
10 10.6 10.3 10.0 9.7 9.3 9.0 8.6 8.2 7.8
16 16.8 16.5 16.0 15.5 15.2 14.7 14.2 13.8 13.3
20 21.0 20.6 20.0 19.4 19.0 18.4 17.8 17.4 16.8
25 26.2 25.7 25.0 24.2 23.7 23.0 22.2 21.5 20.7
32 33.5 32.9 32.0 31.4 30.4 29.8 28.4 28.2 27.5
40 42.0 41.2 40.0 38.8 38.0 36.8 35.6 34.4 33.2
50 52.5 51.5 50.0 48.5 47.4 45.5 44.0 42.5 40.5
63 66.2 64.9 63.0 61.0 58.0 56.7 54.2 51.7 49.2
[1:113% In 12:145% In accordng to IEC60898-1]

110
RESIDUAL CURRENT CIRCUIT BREAKERS
RCCB is applicable to electric circuits with rated voltage 240/415VAC, frequency 50/60Hz
and rated current up to63A. The RCCBs provides indirect protection to the operator’s body
under such condition that the exposed live parts should be connected to a proper earthing
pole. The RCCB also provides protection against the fi re danger caused by earth fault
current due to function failure of over current protection device.

RK63 series

FEATURES APPROVAL
n RCCBs with rated sensitivity up to 30mA can be used as n CE marking
supplementary protecting device in case other protecting
n CB Certificate
device fails its protection against electric shock.

n RCCBs designed for household installation and other similar


application, is for non-professional operation, and no
maintenance is required.

n RCCBs provides no protection against electric shock resulted


from direct contacts of both protected lines, or leakage COLORED HANDLES
current between these two lines.

n Particular devices such as surge protective devices, surge n Black only.


arresters etc are recommended to installation at upstream
line to RCCBs as precaution against potential surge voltage
and current occurring at its power input side.

n Satisfying conditions and applications as mentioned above,


RCCBs with ON-OFF indicating device is considered suitable
for isolation function.

111
SPECIFICATIONS

Type RK63

Protection Ground fault

Rated current 25, 32, 40, 63A

Operating I∆n 30, 100, 300mA (non-adjustable)

Non operating I∆n 0.5I∆n

Number of poles 2, 4 pole

Rated voltage 240VAC (2P), 240/415VAC(4P)

Residual current off time ≤0.1 sec.

Standards IEC61008

Approval SEMKO CB scheme

Type of trip of grand fault Electro-magnetic (No over current relay)


Conditional short circuit
6kA
capacity (Inc)
Rated making 500A for In=25,32,40A
capacity (Im) 630A for In=63A
Electrical endurance 6,000 times

Installation 35mm DIN rail

Width 17.8mm per pole

Type of terminal Lug type (Cable up to 35mm2)

(mm)

Dimension

4P 2P

112
MIN. SALES LOT

n MCBs

Type Min. sales lot (pcs.)

BK63 1P BTK63 1P 120

BK63 2P BTK63 2P 60

BK63 3P BTK63 3P 40

BK63 4P BTK63 4P 30

n RCCBs

Type Min. sales lot (pcs.)

RK63 2P 60

RK63 4P 30

113
AIR CIRCUIT BREAKERS
ORDERING
ACB
&
Accessories

AKH

Ampere Frame size & Rated current


Type No. of pole Connections
frmae phase array (CT Spec.)
AKH - - 00 Without OCR & CT Draw-out type
AKS 3P / 4P 02 200A
Standard J Manual connection
AKN 06 630AF D 3 3P (D) 04 400A
type 06 630A Automatic
RST (N) A
04 400A connection
AKN
AKH 08 830AF 06 630A Fixed type
08 800A H Horizontal type
4P
10 1000AF Reverse 10 1000A V Vertical type
13 1250AF W 4 4P (D, W) 13 1250A Mixed type
phase type
16 1600AF NRST 16 1600A M Line: Horizontal
AKS 20 2000AF 20 2000A Load: Vertical
Mixed type
N Line: Vertical
Load: Horizontal
P Front type
06 630A
3P / 4P
Standard 08 800A
D 3 3P (E) 10 1000A
20 2000AF type
RST (N) 13 1250A
AKH AKS 16 1600A
4P 20 2000A
25 2500AF Reverse 25 2500A
W 4 4P (E, X)
32 3200AF phase type 32 3200A
NRST
40 4000AF 40 4000A

3P/4P
Standard
40 4000AF D 3 3P (F) 40 4000A
type
RST(N)
AKS
4P
Reverse
50 5000AF W 4 4P (F, Y) 50 5000A
phase type
NRST

3P/4P
40 4000AF Standard 40 4000A
D 3 3P (G)
type
RST(N)
AKH AKS 50 5000AF 50 5000A
4P
Reverse
W 4 4P (G, Z)
63 6300AF phase type 63 6300A
NRST

114
Motor rated voltage Shunt coil rated voltage Trip relay
MA Without Motor D0 Without Shunt coil
M1 AC / DC 100 – 130V D1 AC / DC 100 – 130V
M2 AC / DC 200 – 250V D2 AC / DC 200 – 250V
M3 DC 125V D3 DC 125V
M4 DC 24 – 30V D4 DC 24 – 30V
M5 DC 48 – 60V D5 DC 48 – 60V
M6 AC 380 – 415V D6 AC 380 – 480V
M7 AC 440 – 480V D7 AC 48V
M8 AC 48V

Closing coil rated voltage Closing coil rated voltage UVT coil rated voltage
D0 Without Closing coil AX Standard OFF-Charge 3a3b U0 Without UVT coil
D1 AC / DC 100 – 130V AC Standard ON-Charge 3a3b U1 AC / DC 100 – 130V
D2 AC / DC 200 – 250V BX Standard OFF-Charge 5a5b U2 AC / DC 200 – 250V
D3 DC 125V BC Standard ON-Charge 5a5b U3 DC 125V
D4 DC 24 – 30V HX High capacity OFF-Charge 5a5b U4 DC 24 – 30V
D5 DC 48 – 60V HC High capacity ON-Charge 5a5b U5 DC 48 – 60V
D6 AC 380 – 480V CC Standard ON-Charge 6a6b U6 AC 380 – 480V
D7 AC 48V JC High capacity ON-Charge 6a6b U7 AC 48V
*UVT Delay module is available over
AC / DC 48V

Accessories

AL AL1 + MRB Trip alarm contact 1a + Manual reset button


A2 AL1 + AL2 + MRB Trip alarm contact 2a + Manual reset button
A3 AL1 + MRB + RES (AC / DC 100 – 130V) Trip alarm contact 1a + Manual reset button + Remote reset switch
A4 AL1 + MRB + RES (AC / DC 200 – 250V) Trip alarm contact 1a + Manual reset button + Remote reset switch
A5 AL1 + MRB + Auto reset AL + Auto reset type
A6 AL1 + AL2 + MRB + Auto reset A2+ Auto reset type
A7 AL1 + MRB + RES (AC / DC 100 – 130V) + Auto reset A3 + Auto reset type
A8 AL1 + MRB + RES (AC / DC 200 – 250V) + Auto reset A4 + Auto reset type
C C Counter
S CS2 Charge switch communication
B B ON / OFF button lock
M MI Mechanical Interlock
D DI or MOC Door Interlock or Mechanical Operated Cell Switch
K K1 Key Lock
K2 K2 Key Interlock set
K3 K3 Key Lock double
R RCS Ready to close switch
T TM Temperature Alarm
H 1) SHT2 Double Shut Coil
Note) 1. UVT and SHT2 aare alternative.
2. Other accessories should be ordered seperately.

115
ORDERING
Cradle

AL

Rated current
ACB cradle No. of pole Connections Safety shutter
& frmae
H16D AKH-06 – 16D 3 3P H Horizontal type Without
E
H20D AKH-20D 4 4P V Vertical type safety shutter
H32E AKH-20 – 32E P Front type With safety
F
H40E AKH-40E Mixed type shutter
H50G AKH-40 – 50G M Line: Horizontal
H63G AKH-63G Load: Vertical
N16D AKN-06 – 16D Mixed type Arc cover
S20D AKS-20D N Line: Vertical
Load: Horizontal Without
S32E AKS-20 – 32E N
Arc cover
S40E AKS-40E
Terminal With
S50F AKS-40 – 50F S
connections Arc cover
S50G AKS-40 – 50G
S63G AKS-63G Manual
J
connection
Automatic
A
connection

116
ORDERING
Trip relay

Trip relay type Communication & protection Control voltage & frequency
0 Without trip relay 0 Without trip relay 0 Without trip relay

N G 0
N Normal 0 Without comm. 0 Self-Power, 60Hz
*LSIG configuration as standard 5 Self-Power, 50Hz
- with LED indicators
- without output contacts
*Ground fault system by bector sum

A G 0
A Ammeter G Earth leakage 0 Self-Power, 60Hz
Z Earth leakage (extemal CT, fault current ≤ 30A) 1 AC / DC 100 – 250V, 60Hz
E Earth leakage (extemal CT, fault current > 30A) 2 DC 24 – 60V, 60Hz
C Earth leakage + Comm. 5 Self-Power, 50Hz
K Earth leakage (extemal CT, fault current ≤ 30A) + Comm. 6 AC / DC 100 – 250V, 50Hz
X Earth leakage (extemal CT, fault current > 30A) + Comm. 7 DC 24 – 60V, 50Hz
*LSIG configuration as standard
*Ground fault system
G, C: 4pole unit - fault current over 20% of rated currenty by vector sum
3pole unit - phase unbalanced current over 20% of rated current
Z, K: external CT - out ZCT applied
E, X: external CT - private ZCT applied
*Comm. works under control power
*LSIG output contact works under control power
(LED indicators works without control power)

P G 1
P Power meter C Earth leakage + Comm. 1 AC / DC 100 – 250V, 60Hz
K Earth leakage (extemal CT, fault current ≤ 30A) + Comm. 2 DC 24 – 60V, 60Hz
X Earth leakage (extemal CT, fault current > 30A) + Comm. 6 AC / DC 100 – 250V, 50Hz
A Pre-Trip Alarm + Comm. 7 DC 24 – 60V, 50Hz
*LSIG configuration as standard
*Ground fault system
C: vector sum
K: external CT - out ZCT applied
X: external CT - private ZCT applied
*Comm. works under control power
*Applicable to generator protection purpose
*Voltage module required for P and S types. (supplied separately)
*Ground fault function unavailable at A (Pre-Trip Alarm + Comm.)

S C 1
S Supreme meter C Earth leakage + Comm. 1 AC / DC 100 – 250V, 60Hz
K Earth leakage (extemal CT, fault current ≤ 30A) + Comm. 2 DC 24 – 60V, 60Hz
X Earth leakage (extemal CT, fault current > 30A) + Comm. 6 AC / DC 100 – 250V, 50Hz
A Pre-Trip Alarm + Comm. 7 DC 24 – 60V, 50Hz
*LSIG configuration as standard
*Ground fault system
C: vector sum
K: external CT - out ZCT applied
X: external CT - private ZCT applied
*Comm. works under control power
*Applicable to generator protection purpose
*Voltage module required for P and S types. (supplied separately)
*Ground fault function unavailable at A (Pre-Trip Alarm + Comm.)

Note) The function like Metering, Communication, ZSI, Remote Reset and DO control are not available only under Self-Power condition.

117
R ATINGS

AKH
series

Type AKH-06D AKH-08D AKH-10D AKH-13D AKH-16D AKH-20D


Ampere frame (AF) 630 800 1000 1250 1600 2000
200 400
Rated current (A) (in max) at 40ºC 400 630 1000 1250 1600 2000
630 800
Setting current (A)* Control trip relay (... x in max) (0.4 – 1.0) x in max
Rated current of neutral pole (A) 400
400
630 1000 1250 1600 2000
630
800
Rated insulation voltage (V) (Ui) 1,000
Rated operating voltage (V) (Ue) 690
Rated impulse withstand voltage (kV) (Uimp) 12
Frequency (Hz) 50 / 60
Number of poles (P) 3, 4
Rated breaking capacity (kA sym) 220V / 230V / 380V / 415V 85
IEC 60947-2
AC 50 / 60Hz (Icu) 460V / 480V / 500V 85
JISC 8201-2-1
550V / 600V / 690V 65
Rated service breaking capacity (kA) (Ics) ...% x Icu 100%
Rated making capacity (kA peak) 220V / 230V / 380V / 415V 187
IEC 60947-2
AC 50 / 60Hz (Icm) 460V / 480V / 500V 187
JISC 8201-2-1
550V / 600V / 690V 143
Rated shot-time 1 sec 65
withstand current (kA) (Icw) 2 sec 60
3 sec 50
Operating time (ms) Maximum total breaking time 40
Maximum closing time 80
Life cycle (time) Mechanical Without maintenance 20,000
With maintenance 30,000
Electrical Without maintenance 5,000
With maintenance 10,000
Connections** Draw-out Horizontal connection ● -
/ Fixed Vertical connection ○ ●
Front connection ○ -
Mixed connection ○ -
Weight (kg) Draw-out type Main body Motor charging type 63 / 74 70 / 85
(3P / 4P) (With cradle) Manual charging type 61 / 72 68 / 83
Cradle only 29 / 32 33 / 40
Fixed type Motor charging type 34 / 44 38 / 47
Manual charging type 32 / 42 36 / 45
External dimensions (mm) Draw-out 3P 430 x 334 x 375
(H x W x D) type 4P 430 x 419 x 375
Fixed type 3P 300 x 300 x 295
4P 300 x 385 x 295
Trip relay N, A, P, S type
Certificate & Approval KEMA
*Refer to trip relay specification. **●: Standard, ○: Option

118
AKH-06E AKH-08E AKH-10E AKH-13E AKH-16E AKH-20E AKH-25E AKH-32E AKH-40E AKH-40G AKH-50G AKH-63G
630 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300

630 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300

(0.4 – 1.0) x In max (0.4 – 1.0) x In max

630 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300

1,000 1,000
690 690
12 12
50 / 60 50 / 60
3, 4 3, 4
100 150
100 150
85 100
100% 100%
220 330
220 330
187 220
85 100
75 100
65 100
40 40
80 80
15,000 10,000
20,000 15,000
5,000 2,000
10,000 5,000
● ○ ○
○ ● ●
○ - -
○ - -
87 / 103 104 / 147 181 / 223 186 / 230
85 / 101 102 / 145 179 / 221 184 / 228
44 / 55 58 / 70 97 / 117 102 / 124
44 / 55 63 / 100 98 / 123 103 / 130
42 / 53 61 / 98 96 / 121 101 / 128
430 x 412 x 375 460 x 785 x 375
430 x 527 x 375 460 x 1,015 x 375
300 x 378 x 295 300 x 751 x 295
300 x 493 x 295 300 x 981 x 295
N, A, P, S type N, A, P, S type
KEMA KEMA

119
R ATINGS
AKN AKS
series

Type AKN-06D AKN-08D AKN-10D AKN-13D AKN-16D AKS-20D


Ampere frame (AF) 630 800 1000 1250 1600 2000
200 400
Rated current (A) (in max) at 40ºC 400 630 1000 1250 1600 2000
630 800
Setting current (A)* Control trip relay (... x in max) (0.4 – 1.0) x in max
Rated current of neutral pole (A) 400
400
630 1000 1250 1600 2000
630
800
Rated insulation voltage (V) (Ui) 1,000
Rated operating voltage (V) (Ue) 690
Rated impulse withstand voltage (kV) (Uimp) 12
Frequency (Hz) 50 / 60
Number of poles (P) 3, 4
Rated breaking capacity (kA sym) 220V / 230V / 380V / 415V 65 70
IEC 60947-2
AC 50 / 60Hz (Icu) 460V / 480V / 500V 65 70
JISC 8201-2-1
550V / 600V / 690V 50 65
Rated service breaking capacity (kA) (Ics) ...% x Icu 100% 100%
Rated making capacity (kA peak) 220V / 230V / 380V / 415V 143 154
IEC 60947-2
AC 50 / 60Hz (Icm) 460V / 480V / 500V 143 154
JISC 8201-2-1
550V / 600V / 690V 105 143
Rated shot-time 1 sec 50 65
withstand current (kA) (Icw) 2 sec 42 55
3 sec 36 50
Operating time (ms) Maximum total breaking time 40
Maximum closing time 80
Life cycle (time) Mechanical Without maintenance 20,000
With maintenance 30,000
Electrical Without maintenance 5,000
With maintenance 10,000
Connections** Draw-out Horizontal connection ● -
/ Fixed Vertical connection ○ ●
Front connection ○ -
Mixed connection ○ -
Weight (kg) Draw-out type Main body Motor charging type 63 / 74 70 / 85
(3P / 4P) (With cradle) Manual charging type 61 / 72 68 / 83
Cradle only 29 / 32 33 / 40
Fixed type Motor charging type 34 / 44 38 / 47
Manual charging type 32 / 42 36 / 45
External dimensions (mm) Draw-out 3P 430 x 334 x 375
(H x W x D) type 4P 430 x 419 x 375
Fixed type 3P 300 x 300 x 295
4P 300 x 385 x 295
Trip relay N, A, P type
Certificate & Approval KEMA
*Refer to trip relay specification. **●: Standard, ○: Option

120
AKS-20E AKS-25E AKS-32E AKS-40E AKS-50F AKS-40G AKS-50G AKS-63G
2000 2500 3200 4000 4000 5000 4000 5000 6300
630, 800
1000, 1250 2500 3200 4000 4000 5000 4000 5000 6300
1600, 2000
(0.4 – 1.0) x In max (0.4 – 1.0) x In max (0.4 – 1.0) x In max
630, 800
1000, 1250 2500 3200 4000 4000 5000 4000 5000 6300
1600, 2000
1,000 1,000 1,000
690 690 690
12 12 12
50 / 60 50 / 60 50 / 60
3, 4 3, 4 3, 4
85 100 120
85 100 120
85 85 100
100% 100% 100%
187 220 264
187 220 264
187 187 220
85 85 100
75 75 90
65 65 85
40 40 40
80 80 80
15,000 10,000 10,000
20,000 15,000 15,000
5,000 2,000 2,000
10,000 5,000 5,000
● ○ ○ ○
○ ● ● ●
○ - - -
○ - - -
87 / 103 104 / 147 145 / 173 181 / 223 186 / 230
85 / 101 102 / 145 143 / 171 179 / 221 184 / 228
44 / 50 58 / 70 78 / 90 97 / 117 102 / 124
44 / 55 63 / 100 76 / 94 98 / 123 103 / 130
42 / 53 61 / 98 74 / 92 96 / 121 101 / 128
430 x 412 x 375 460 x 629 x 375 460 x 785 x 375
430 x 527 x 375 460 x 799 x 375 460 x 1,015 x 375
300 x 378 x 295 300 x 597 x 295 300 x 751 x 295
300 x 493 x 295 300 x 767 x 295 300 x 981 x 295
N, A, P type N, A, P type N, A, P type
KEMA KEMA KEMA

121
DIMENSIONS

Fixed type
2000AF

630 – 1600A:
AKH / AKN / AKS-06 – 16D

Front view

Vertical type

Door Frame: DF (AKH / AKN / AKS-D / E)

Note) The dimensions are for drawout type.

122
Horizontal type

Front connection
type

123
DIMENSIONS

Draw-out type
2000AF

630 – 1600A:
AKH / AKN / AKS-06 – 16D

Front view

Vertical type

124
Horizontal type

Front connection
type

125
DIMENSIONS

Fixed type
2000AF

2000A:
AKH / AKS-20D

Front view

Vertical type

126
Draw-out type
2000AF

2000A:
AKH / AKS-20D

Front view

Vertical type

127
DIMENSIONS

Fixed type
4000AF

2000 – 3200A:
AKH / AKN / AKS-20 – 32E

Front view

Vertical type

128
Horizontal type

Front connection
type

129
DIMENSIONS

Draw-out type
4000AF

2000 – 3200A:
AKH / AKN / AKS-20 – 32E

Front view

Vertical type

130
Horizontal type

Front connection
type

131
DIMENSIONS

Fixed type
4000AF

4000A:
AKH / AKS-40E

Front view

Vertical type

132
Horizontal type

133
DIMENSIONS

Draw-out type
4000AF

4000A:
AKH / AKS-40E

Front view

Vertical type

134
Horizontal type

135
DIMENSIONS

Fixed type
5000AF

4000 – 5000A:
AKS-40 – 50F

Front view

Vertical type

136
Horizontal type

18

Door Frame: DF (AKH-G, AKS-F )

Note) The dimensions are for drawout type.

137
DIMENSIONS

Draw-out type
5000AF

4000 – 5000A:
AKS-40 – 50F

Front view

Vertical type

138
Horizontal type

139
DIMENSIONS

Fixed type
6300AF

4000 – 6300A:
AKH / AKS-40 – 50G

Front view

4000A – 5000A 6300A

Vertical type

4000A – 5000A 6300A


18

140
Horizontal type
4000A – 5000A

6300A

141
DIMENSIONS

Draw-out type
6300AF

4000 – 6300A:
AKH / AKS-40 – 50G

Front view

4000A – 5000A 6300A

Vertical type

4000A – 5000A 6300A

142
Horizontal type
4000A – 5000A

6300A

143
memo

144