1.0 Introduction
10.0 Load Combination At Foundation Base & Check for Base Pressure
1.0 INTRODUCTION
The Project is Development of Delhi Merrut Expressway from Km 0+000 To 27+500 Including 6/8
Laning of NH-24 From Km. 49+346 (Hapur Bypass) In the State of Delhi and Uttarpradesh Under
Package-1 from Existing Km. 0+000 to Existing Km. 8+360 (Delhi-UP Border) In The State of Delhi On
Hybrid Annunity Mode.
M/s WELSPUN has entrusted the work on EPC to M/s GAWAR Constrution Ltd. The design consulting
work is entrusted by M/s GAWAR to "B&S Engineering Consultants Pvt. Ltd., Noida (BSEC)" for
preparation of detailed design and drawings of Bridge over River Yamuna.
The span arrangement comprises of 13 spans with span configuration of 13 x 42.4 metres. The bridge
has two independent carriageways (on both side of existing bridges) of overall width for each
carriageway as 20.5m. The total length of the bridge is 551.2m. PSC pretensioned girder & cast in situ
This
deck design note presents
slab is proposed the design ofsupported
as superstructure well foundations forrectangular
over PSC Abutment pier
A2. The properties
cap (18.45m of soil and
X 3.4m) are
considereded as per soil report. Due to liquefaction of 10.5m, MSL is taken at 196.555 i.e.
RCC solid circular pier of 3.0m diameter. Pile foundation are proposed for piers while Well foundation 10.5m
below
of 8.0mbore
dia hole level. as foundation for Abutments.
is proposed
For calculation of seismic coefficient R is taken 3 and Sa/g as 2.5 and Zone factor as 0.24 for zone IV
is considered. 35% extra seismic forces are consiered in design of well. Safe Bearing capacity of soil at
founding level is directly taken from geotech report. The Founding level of well foundation is proposed
as 172m and safe gross bearing capacity at founding level is 125t/m2. The properties of soil for i.e c
and ɸ are taken from geotechnical investigation report and same is used for calculating active and
passive earth pressure.
The calculation of DL, SIDL, LL & wind can be referred from the design note no.
BSEC/1701/MJB/0+805/DN-02. Backfilling behind abutment is considered with material having
properties C not less than 0 and φ not less than 32 0. For calculations of active and passive earth
pressure, procedure mentioned in IRC:78 is followed. Steining is checked for different load
combinations in SLS and ULS as per latest codes. SAM software is used to check the stress at different
section of well. Base pressure is checked for different laod combination without any load factors (in
accordance with IRC:78).
1. IRC : 6 –2014
2. IRC : 78 – 2014
c) Subsoil Strata
g) Well Data
Type of Founding Strata = SAND
Type of Steining = RCC
Transverse Dimension of Circular Well, W = 7.00
Constant K (as per IRC 78:2014) = 0.030
Steining thickness required = 1.2424 m.
Steining thickness provided, ts = 1.30 m.
Curb Height required = 2.626 m.
Curb Height provided, hc = 2.630 m.
Thickness of Well Cap = 1.50 m.
Dredge hole Diameter = 4.40 m.
h) Well Cap Data
Area of Well Cap = 38.485 Sqm
3. CALCULATION FOR WIND LOAD
conservative side)
e 4, IRC 6:2010)
4 x (3.44+1))
HL(*) Trans.
Load Vertical HL: Reduction
Details of Load cases Seismic Mom.
Case Load (t.) Normal (t.) Factor
(t.) (tm.)
1 MAX V CASE CLASS A 3L 115.6 32.9 0.0 196.0 0.9
P = (P'-260+4800/L) x (16.5-W)/15
Trans. Moment,
MT (t.m)
0.0
59.0
5. Load Calculation of Substructure -
C/L of Brg.
B
950 650
400
263.56 (Top of Abutment Cap)
1500 1500
2000 Width of dirt wall =
Width of abutment wall at base =
2000 No of Abutments shafts
3060
C/L of WELL
L B H
COMPONENT (M) (M) (M) No. OF
'Y' Moment at
Weight c.g from well
COMPONENT (t) cap top (m) R.L of c.g Base due to
(m) 'Y' force
Calculation of Loads & Moments at top of Well cap due to Seismic Forces on Abutment
RL of Moment at Abutment
V Load Vseismic Hseismic base, ML / MT due to
S No. Component Force
(T) (T) (T) (m) Hseismic (t.m)
RL of Moment at Fndn.
V Load Vseismic Hseismic base, ML / MT due to
S No. Component Force
(T) (T) (T) (m) Hseismic (t.m)
VOLUME
WEIGHT (T)
(m3)
27.10 67.8
42.00 105.0
10.17 25.4
24.20 60.5
206.08 412.2
'X' - Distance
of c.g from Moment at
front face of Base due to
abutment 'X' force
(about '1')
(m)
2.550 172.8
1.750 183.8
1.553 39.5
5.250 317.6
1.312 540.7
1254.4
m
m
m
(For HFL Case - with 15% buoyancy)
(For LWL Case - with 15% buoyancy)
Moment, ML due to
Vseismic,
(w.r.t C/L of Brg.)
(t.m)
0.0
0.0
25.2
25.22
Moment, ML due to
Vseismic,
(w.r.t C/L of Brg.)
(t.m)
0.0
0.0
31.5
31.52
Dry Submerged
Normal Seismic Normal Seismic γd = 1.8 t/m3
#REF! Ka Ca Ka' Ca' γsub = 1.0 t/m3
VERTICAL
NORMAL CASE EFFECTIVE MULTIPLYING
EP DYNAMIC INCREMENT
STATIC PRESSURE PRESSURE FACTOR
DRY
3x ( Ca Ka)
H/2
Ka x γd x H γd x H
NORMAL CASE DYNAMIC INC
F = Ka x Ƴd x H 2
3/4HxƳdx(CaKa) x 2/3xH
2 =(CaKa)x1.8xH 2
###
SUBMERGED
3(CaKa)
Ƴdx(HH')
(Ƴs x H') (Ka'xƳsxH') (Ƴs x H')
NORMAL CASE DYNAMIC INC
F =
LLSUR Ƴd x 1.2 2(CaKa) 2(CaKa)xƳdx1.2
2/3H 2/3H
Ka x Ƴd x 1.2 Ƴd x 1.2
NORMAL CASE DYNAMIC INC
=(CaKa) x Ƴd x 1.2 x H
6. Self weight of well foundation
Calculation of Basic Dimensions of Well Foundation
(ix) Wt. of Water & soil above cap & projections = 59.0 t.
(ix) Weight of Water & soil above cap & projections - = 44.8 t.
Calculation of Loads & Moments at Well Base due to Seismic Forces on Well
Moment, ML / MT
(t.m)
593.14
593.14
7 Seismic Forces on Superstructure - For Substructure design
Salient Levels -
Calculation of Active Earth Pressure & Passive Resistance for HFL Case
Formation 266.900
Level
F1 F2 HFL 262.000
p2
Total Horiz. Force Due to Active Earth till Abut Base, Fa = 153.40 t. LL Sur. Fa 58.1
and corresponding moment , Ma = 709.80 t.m. Mom 348.6
Total Horiz. Force Due to Active Earth till Fdn. level, Fa = 1131.60 t. LL Sur. Fa 58.1
and corresponding moment , Ma = 23134 t.m. Mom 2382.1
Calculation of Active Earth Pressure & Passive Resistance for LWL Case
Width of Abutment = 0.7 m
Transverse width of well at top = 7.0 m.
Transverse Width of Well at base = 7.2 m.
Area of Well at Base = 40.2 m2
Sec. modulus of Well at Base, ZL = 35.9 m3
Formation 266.900
Level
F3 LWL 253.500
p1 p3
F4
p4 Bottom of Well Cap 257.500
p4'
F5
p5 Scour Level 257.500
p6 p10
F6 F11
p6 p11 Change of 255.000
p7 p12 Strata
F7
F12
p7 p13 Change of 252.500
p8 p14 Strata
Total Horiz. Force Due to Active Earth till Abut Base, Fa = 166.90 t. LL Sur. Fa 58.2
and corresponding moment , Ma = 734.36 t.m. Mom 116.40
Total Horiz. Force Due to Active Earth till Fdn. level, Fa = 1416.78 t. LL Sur. Fa 58.2
and corresponding moment , Ma = 29328.15 t.m. Mom 2153.4
m.
m.
m.
m.
m.
m.
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
ure for stratum 1 & 2
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
t
t.m.
t
t.m.
m
m.
m.
m.
m.
m.
m.
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
ure for stratum 1 & 2
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
t.
t.m.
t.
t.m.
8a. Calculation of Net Earth Resistance : Seismic Case
Salient Levels -
Calculation of Static Component of Active Earth Pressure & Passive Resistance for HFL Case
Formation 266.900
Level
F1 F2 HFL 262.000
p2
Total Horiz. Force Due to Active Earth till Abut Base, Fa = 153.40 t. LL Sur. Fa 58.1
and corresponding moment , Ma = 709.80 t.m. Mom 348.60
Total Horiz. Force Due to Active Earth till Fdn. level, Fa = 1131.60 t. LL Sur. Fa 58.1
and corresponding moment , Ma = 23134.33 t.m. Mom 2382.10
Calculation of Static Component of Active Earth Pressure & Passive Resistance for LWL Case
Formation 266.900
Level
F3 LWL 253.500
p1 p3
F4
p4 Bottom of Well Cap 257.500
p4'
F5
p5 Scour Level 257.500
p6 p10
F6 F11
p6 p11 Change of 255.000
p7 p12 Strata
F7
F12
p7 p13 Change of 252.500
p8 p14 Strata
Total Horiz. Force Due to Active Earth till Abut Base, Fa = 166.90 t. LL Sur. Fa 58.2
and corresponding moment , Ma = 734.36 t.m. Mom 116.40
Total Horiz. Force Due to Active Earth till Fdn. level, Fa = 1416.78 t. LL Sur. Fa 58.2
and corresponding moment , Ma = 29328.15 t.m. Mom 2153.4
-0.279
1.088
-0.304
1.102
-0.279
1.088
-0.304
1.102
-0.279
5.737
0.000
0.000
-0.279
5.737
0.000
0.000
-0.279
5.737
0.000
0.000
-0.279
5.737
0.000
0.000
m
m.
m.
m.
m.
m.
m.
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
ssure for stratum 1 & 2
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m
m
m
m.
m.
m.
m.
m.
m.
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t./m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
t/m2
ssure for stratum 1 & 2
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
m.
t.
t.m.
t.
t.m.
PRESSURE UNDER
T
TM
T
TM
T
TM
T
TM
LOADS & MOMENTS AT BASE OF FOUNDATION
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.000 m
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
16.3 FROM WELL FOUNDATION +/- 11.5 0.0 0.0 0.0 0.0
17 WIND FORCES
17.1 Without Live Load +/- 80.1 0.0 0.0 0.0 65.6
17.2 With Live Load +/- 60.0 0.0 0.0 0.0 62.15
LOAD COMBINATIONS AT FOUNDATION BASE & CHECK FOR BASE PRESSURE
HEIGHT OF WELL = 35 m
LOAD CASE 1 : DL+SIDL+LL1+FPLL1+EP (HFL) - NORMAL CASE UNDER HFL
LOAD V. LOAD HL (T) ML (T.M) HT (T.M)
LOAD COMPONENT
FACTOR (T)
1 D.L OF SUPERSTRUCTURE 1.0 497.5 0.0 0.0 0.0
7 WT. OF WATER / SOIL OVER W. CAP 1.0 0.0 0.0 0.0 0.0
7 WT. OF WATER / SOIL OVER W. CAP 1.0 0.0 0.0 0.0 0.0
SUMMARY OF LOADS & MOMENTS AT WELL BASE & CHECKING OF BASE PRESSURE
MAPPLIED MPASSIVE DESIGN sMAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
42.2 2872.4
42.1 2834.8
42.2 2872.4
38.6 4299.0
34.3 593.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
41.6 2729.0
42.6 2646.7
E PRESSURE
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
0.0
196.0
0.0
1,356.5)x35.0/160 = 1062.6 tm
AT BASE = 0
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
0.0
196.0
0.0
1,356.5)x35.0/160 = 1134.1 tm
AT BASE = 0
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
10482.1
0.0
0.0
10521.3
0.0
1,255.8)x35.0/160 = 1014.6 tm
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
3144.6
0.0
0.0
3183.8
0.0
1,255.8)x35.0/160 = 1014.6 tm
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
10482.1
0.0
0.0
10521.3
0.0
1,255.8)x35.0/160 = 1086.1 tm
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
3144.6
0.0
0.0
3183.8
0.0
1,255.8)x35.0/160 = 1086.1 tm
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
2646.7
0.0
2842.7
0.0
1,356.5)x35.0/160 = 1075.7 tm
AT BASE = 0
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
2646.7
0.0
2842.7
0.0
1,356.5)x35.0/160 = 1147.3 tm
AT BASE = 0
RE
sMIN =
STATUS
P/A-M/Z
64.0 SAFE
72.2 SAFE
62.8 SAFE
62.8 SAFE
70.9 SAFE
70.9 SAFE
65.5 SAFE
73.7 SAFE
LOADS & MOMENTS AT BASE OF FOUNDATION
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.000 m
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
16.3 FROM WELL FOUNDATION +/- 11.5 0.0 0.0 0.0 0.0
17 WIND FORCES
17.1 Without Live Load +/- 80.1 0.0 0.0 0.0 65.6
17.2 With Live Load +/- 60.0 0.0 0.0 0.0 62.15
LOAD COMBINATIONS AT FOUNDATION BASE & CHECK FOR BASE PRESSURE
HEIGHT OF WELL = 35 m
LOAD CASE 1 : DL+SIDL+LL1+FPLL1+EP (HFL) - NORMAL CASE UNDER HFL
LOAD V. LOAD HL (T) ML (T.M) HT (T.M)
LOAD COMPONENT
FACTOR (T)
1 D.L OF SUPERSTRUCTURE 1.0 497.5 0.0 0.0 0.0
7 WT. OF WATER / SOIL OVER W. CAP 1.0 0.0 0.0 0.0 0.0
7 WT. OF WATER / SOIL OVER W. CAP 1.0 0.0 0.0 0.0 0.0
SUMMARY OF LOADS & MOMENTS AT WELL BASE & CHECKING OF BASE PRESSURE
MAPPLIED MPASSIVE DESIGN sMAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
7.2 488.2
7.1 480.4
7.2 488.2
3.6 397.3
34.3 593.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
41.6 2729.0
42.6 2646.7
E PRESSURE
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
0.0
196.0
0.0
1,356.5)x35.0/160 = 1062.6 tm
AT BASE = 0
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
0.0
196.0
0.0
1,356.5)x35.0/160 = 1134.1 tm
AT BASE = 0
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
1996.2
0.0
0.0
2035.4
0.0
1,255.8)x35.0/160 = 1014.6 tm
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
598.8
0.0
0.0
638.0
0.0
1,255.8)x35.0/160 = 1014.6 tm
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
1996.2
0.0
0.0
2035.4
0.0
1,255.8)x35.0/160 = 1086.1 tm
MT (T.M)
0.0
0.0
39.2
0.0
0.0
0.0
0.0
0.0
598.8
0.0
0.0
638.0
0.0
1,255.8)x35.0/160 = 1086.1 tm
0.0
0.0
196.0
0.0
0.0
0.0
0.0
0.0
2646.7
0.0
2842.7
0.0
1,356.5)x35.0/160 = 1075.7 tm
AT BASE = 0
MT (T.M)
0.0
0.0
196.0
0.0
0.0
0.0
0.0
2646.7
0.0
2842.7
0.0
1,356.5)x35.0/160 = 1147.3 tm
AT BASE = 0
RE
sMIN =
STATUS
P/A-M/Z
64.0 SAFE
72.2 SAFE
62.8 SAFE
62.8 SAFE
70.9 SAFE
70.9 SAFE
65.5 SAFE
73.7 SAFE
CHECK FOR STRESSES IN STEINING SLS CASE HFL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 252.93 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVE
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
16 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
13.4 882.2
13.4 835.6
MT (T.M)
0.0
0.0
196.0
59.0
0.0
0.0
0.0
501.3
0.0
0.0
756.4
0.0
356.5)x6.1/160 = 322.1 tm
s MIN = SECTION
P/A-M/Z SAFE AS
18.7 PCC
CHECK FOR STRESSES IN STEINING SLS CASE HFL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 252.99 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
13.4 878.7
13.4 832.2
MT (T.M)
0.0
0.0
234.0
59.0
0.0
0.0
0.0
832.2
0.0
0.0
1125.3
0.0
300.9)x6.0/160 = 309.3 tm
s MIN =SECTION
P/A-M/Z SAFE AS
11.5 PCC
CHECK FOR STRESSES IN STEINING SLS CASE LWL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 252.19 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVE
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
14.2 931.0
14.2 881.8
MT (T.M)
0.0
0.0
312.0
59.0
0.0
0.0
0.0
529.1
0.0
0.0
900.1
0.0
320.9)x6.8/160 = 330.0 tm
s MIN = SECTION
P/A-M/Z SAFE AS
9.0 PCC
CHECK FOR STRESSES IN STEINING SLS CASE LWL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 252.24 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
14.1 928.0
14.1 878.9
MT (T.M)
0.0
0.0
234.0
59.0
0.0
0.0
0.0
878.9
0.0
0.0
1172.0
0.0
300.9)x6.8/160 = 325.3 tm
s MIN =SECTION
P/A-M/Z SAFE AS
5.3 PCC
CHECK FOR STRESSES IN STEINING ULS CASE HFL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 251.66 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
14.7 965.6
14.7 914.5
MT (T.M)
0.0
0.0
468.0
88.6
0.0
0.0
0.0
823.1
0.0
0.0
1379.7
0.0
814.8)x7.3/160 = 469 tm
s MIN =SECTION
P/A-M/Z SAFE AS
-2.1 PCC
CHECK FOR STRESSES IN STEINING ULS CASE HFL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 252.22 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
10 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
14.2 928.9
14.2 879.8
MT (T.M)
0.0
0.0
405.6
59.0
0.0
0.0
0.0
703.8
0.0
0.0
1168.5
0.0
344.9)x6.8/160 = 335.4 tm
s MIN =SECTION
P/A-M/Z SAFE AS
-11.5 PCC
CHECK FOR STRESSES IN STEINING ULS CASE LWL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 250.70 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
7 WT. OF WATER / SOIL OVER W. CAP 1.35 0.0 0.0 0.0 0.0
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
15.7 1028.9
15.7 974.5
MT (T.M)
0.0
0.0
468.0
88.6
0.0
0.0
0.0
0.0
877.0
0.0
0.0
1433.6
0.0
814.8)x8.3/160 = 500.5 tm
s MIN =SECTION
P/A-M/Z SAFE AS
-19.5 PCC
CHECK FOR STRESSES IN STEINING ULS CASE LWL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 251.33 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
11 WIND FORCES
SUMMARY
MAPPLIED MPASSIVE DESIGN s MAX =
LOAD CASE V. LOAD (T)
(T.M) (T.M) MOMENT P/A+M/Z
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
15.0 987.2
15.0 935.0
MT (T.M)
0.0
0.0
405.6
59.0
0.0
0.0
0.0
935.0
0.0
0.0
1399.6
0.0
344.9)x7.7/160 = 355.8 tm
s MIN =SECTION
P/A-M/Z SAFE AS
-26.9 PCC
CHECK FOR STRESSES IN STEINING ULS CASE HFL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 250.58 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.00 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVE
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
15.3 FROM WELL FOUNDATION +/- 11.5 0.0 0.0 0.0 0.0
LOAD COMBINATIONS AT 250.58m LEVEL
HEIGHT OF WELL 8.42 m
LOAD CASE 9 : DL+SIDL+LL2+FPLL2+EP - Seis Long Case under HFL
LOAD V. LOAD HL (T) ML (T.M) HT (T.M)
LOAD COMPONENT
FACTOR (T)
TRANSVERSE
0 0
0 0
0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
15.6 1061.9
15.6 1046.9
15.6 1061.9
12.0 1336.1
7.7 132.9
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
MT (T.M)
0.0
0.0
62.4
11.8
0.0
0.0
0.0
1528.4
0.0
0.0
0.0
0.0
0.0
1602.6
0.0
718.0)x8.4/160 = 478.6 tm
s MIN = SECTION
P/A-M/Z SAFE AS
-78.8 PCC
CHECK FOR STRESSES IN STEINING ULS CASE LWL
LOADS & MOMENTS IN STEINING AT MAXIMUM MOMENT POINT
LEVEL AT WHICH THE STRESSES ARE CHECKED = 250.05 m
ECC. OF C/L OF BRG. TO C/L OF WELL = 0.000 m
PERMISSIBLE COMPRESSIVE STRESS IN CONCRETE (NORMAL) = 1366.80 T/m2
PERMISSIBLE TENSILE STRESS IN CONCRETE (NORMAL) = -173.40 T/m2
LONGITUDINAL TRANSVE
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
15 WIND FORCES
TRANSVERSE
0 0
0 0
0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 59.0
0 0
0 0
0 0
0 0
16.1 1098.1
16.1 1082.7
16.1 1098.1
12.5 1395.3
8.2 142.1
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
16.3 1071.6
16.3 1014.9
MT (T.M)
0.0
0.0
39.2
11.8
0.0
0.0
0.0
1591.7
0.0
0.0
0.0
0.0
0.0
1642.7
0.0
725.2)x9.0/160 = 496.6 tm
s MIN = SECTION
P/A-M/Z SAFE AS
-77.9 PCC
Calculation of Reinforcement
Vertical Reinforcement
The steining is designed as RCC member with minimum reinforcement of 0.2% of c/s
area including 0.06% minimum reinforcement at inner face of steining.
Hoop Reinforcement
Hoop Reinforcement= 0.04 % of volume / unit length of steining [ Ref: Cl 708.3.4 of IRC: 78 - 2014]
9312 cm / m height of steining
3
Min area of reinf required = 72kg / m3 of concrete of well curb [ Ref: IRC 78-2000; Cl 708.7.3]
Total volume of concrete of well curb = 41.56 m3
So min required wt of reinforcement = 2991.977 kg
Reinforcement Provided
Description No. Bar Dia Af (cm2) Dia of Ring Length(m) Weight(kg) Shape
Vertical Reinforcement
The steining is designed as RCC member with minimum reinforcement of 0.2% of c/s
area including 0.06% minimum reinforcement at inner face of steining.
Hoop Reinforcement
Hoop Reinforcement= 0.04 % of volume / unit length of steining [ Ref: Cl 708.3.4 of IRC: 78 - 2014]
9312 cm / m height of steining
3
2 SIDL 45.0 0 0 0 0
15.3 FROM WELL FOUNDATION +/- 0.0 0.0 0.0 0.0 0.0
16 WIND FORCE
A. SLS COMBINATIONS
B. ULS COMBINATIONS
5 ULS Basic Comb (LL Leading 1): 761 286.1 1116 55.9
6 ULS Basic Comb (LL Leading 2): 613 286.1 1116 55.9
7 ULS Seis Comb (Seis Leading 1): 543 302.4 1199 67.8
8 ULS Seis Comb (Seis Leading 2): 486 198.8 758 93.2
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 0
0 0
0 0
0 0
7.2 488.2
7.1 480.4
7.2 488.2
3.6 294.3
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
7.0 459.8
7.0 435.5
MT (T.M)
0.0
0.0
196.0
59.0
0.0
0.0
261.3
0.0
0.0
516.3
MT (T.M)
0.0
0.0
147.0
44.3
0.0
0.0
435.5
0.0
0.0
626.7
MT (T.M)
0.0
0.0
225.4
67.9
0.0
0.0
391.9
0.0
0.0
685.2
MT (T.M)
0.0
0.0
225.4
67.9
0.0
0.0
391.9
0.0
0.0
685.2
MT (T.M)
0.0
0.0
294.0
88.6
0.0
0.0
391.9
0.0
0.0
774.5
MT (T.M)
0.0
0.0
294.0
88.6
0.0
0.0
391.9
0.0
0.0
774.5
MT (T.M)
0.0
0.0
39.2
11.8
0.0
0.0
0.0
0.0
0.0
352.1
0.0
403.1
MT (T.M)
0.0
0.0
39.2
11.8
0.0
0.0
0.0
0.0
653.2
0.0
0.0
0.0
704.2
MT (TM)
516
627
685
685
774
774
403
704
LOADS & MOMENTS AT BASE OF ABUTMENT
ECC. OF C/L OF BRG. TO C/L OF ABUTMENT = 0.00 m
LONGITUDINAL TRANSVER
S. No. COMPONENT V. LOAD (T)
HL (T) L.ARM (M) ML (T.M) HT (T.M)
2 SIDL 45.0 0 0 0 0
15.3 FROM WELL FOUNDATION +/- 0.0 0.0 0.0 0.0 0.0
16 WIND FORCE
A. SLS COMBINATIONS
B. ULS COMBINATIONS
5 ULS Basic Comb (LL Leading 1): 761 286.1 1116 55.9
6 ULS Basic Comb (LL Leading 2): 613 286.1 1116 55.9
7 ULS Seis Comb (Seis Leading 1): 543 339.9 1342 84.8
8 ULS Seis Comb (Seis Leading 2): 509 210.4 790 116.5
TRANSVERSE
0 0
0 0
0 196.0
0 312.0
0 196.0
0 0.0
0 59.0
0 0
0 0
0 0
0 0
7.2 488.2
7.1 480.4
7.2 488.2
3.6 294.3
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
7.0 459.8
7.0 435.5
MT (T.M)
0.0
0.0
196.0
59.0
0.0
0.0
261.3
0.0
0.0
516.3
MT (T.M)
0.0
0.0
147.0
44.3
0.0
0.0
435.5
0.0
0.0
626.7
MT (T.M)
0.0
0.0
225.4
67.9
0.0
0.0
391.9
0.0
0.0
685.2
MT (T.M)
0.0
0.0
225.4
67.9
0.0
0.0
391.9
0.0
0.0
685.2
MT (T.M)
0.0
0.0
294.0
88.6
0.0
0.0
391.9
0.0
0.0
774.5
MT (T.M)
0.0
0.0
294.0
88.6
0.0
0.0
391.9
0.0
0.0
774.5
MT (T.M)
0.0
0.0
39.2
11.8
0.0
0.0
0.0
0.0
0.0
440.2
0.0
491.2
MT (T.M)
0.0
0.0
39.2
11.8
0.0
0.0
0.0
0.0
816.5
0.0
0.0
0.0
867.5
MT (TM)
516
627
685
685
774
774
491
867
DESIGN OF ABUTMENT SHAFT (SLS)
Abutment shaft is designed as cantilever for longitudinal moment on conservative side.
S.no. Refrence Unit
Load Data
1 Moment KN-m
Material Data
2 Grade of Steel
3 Charecterstic strength of reinforcement (f yk) Table 18.1,IRC 112 MPa
4 Partial factor for steel (γs) Cl 6.2.2,IRC 112
5 Design value for tensile strength (fyd=fyk/γs) Cl 6.2.2,IRC 112 MPa
6 Modulus of Elasticity of Steel (ES) Cl 6.2.2,IRC 112 GPa
7 Grade of Concrete
8 Charecterstic compressive strength (fck) Table 6.5,IRC 112 MPa
9α Cl 6.4.2.8,IRC 112
10 Concrete material factor (γm) Cl 6.4.2.8,IRC 112
11 Design value for concrete compressive strength (fcd= αfck/γm) Cl 6.4.2.8,IRC 112 MPa
12 Modulus of Elasticity of Concrete (Ecm) Table 6.5,IRC 112 GPa
Geometric Data
13 Width of Slab/Beam (b) mm
14 Total depth of Slab/Beam (D) mm
15 Cover to Reinforcement ,face in contact with earth ( c ) mm
16 Dia of Reinforcement (φ) in first layer mm
17 Dia of Reinforcement (φ) in second layer mm
18 Effective depth of beam/Slab (d) mm
19 Spacing of Reinforcement (s) or mm
20 Number of Bar (n) Nos
21 Area of Reinforcement (At) mm2
22 Reinforcement (%)
Stress Check
23 Concrete Cross Sectional Area (AC) mm2
24 Perimeter in contact with atmosphere (u) mm
25 Notional Size (=2AC/u) mm
26 Age at Loading days
27 Relative humidity Table 6.9 , IRC 112 %
28 Final Creep Co-efficient of 28 days (φ) Table 6.9 ,IRC 112
29 Effective Modulus of Elasticity of Concrete (E eff) Cl 6.4.2.5,IRC 112 MPa
30 Modular ratio (m)
31 Allowable stress in Steel Cl 12.2.2,IRC 112 MPa
32 Allowable stress in Concrete Cl 12.2.2,IRC 112 MPa
33 Position of nuetral axis from comp. face (x) mm
34 MOA of Compression area mm2
35 MOA of Tension area mm2
36 Diff. mm2
37 MOI of cracked section mm4
38 Stress in tension reinf. MPa
39 Status
40 Stress in concrete MPa
41 Status
Abt. Base
9890
Fe 500
500
1.150
434.783
200
M 40
40
0.670
1.500
17.867
33
11600
500
50
20
0
450
100
116
36442
0.628
5800000
12100
958.678
7.0
80
2.000
11000.0
18.182
400.0
19.20
176.7
1.81E+08
1.81E+08
0.000
7.08E+10
693.935
CHECK
24.676
CHECK
DESIGN OF ABUTMENT SHAFT BY BENDING THEORY (As per IRC 112:2011) ULS
At face of
S. No Type support
Load Data
1 Moment KN-m 14270
2 Shear Force VED KN 3580
3 Reduction factor b 1.000
4 Design Shear Force KN 3580
5 Axial force, NEd KN 5692.7
Material Data
6 Charecterstic strength of reinf. (fyk) MPa 500
7 Partial factor for steel (γs) 1.150
8 Design yield strength of reinf. (fyd=fyk/γs) MPa 434.8
9 Modulus of Elasticity of Steel (ES) GPa 200.0
10 Charecterstic compressive strength of concrete (fck) MPa 40
11 α 0.670
Geometric Data
14 Width of Slab/Beam (b) mm 11600
15 Total depth of Slab/Beam (D) mm 700
16 Cover to Reinforcement ( c ) mm 75
17 Dia of Reinforcement (φ) mm 25
18 Spacing of Reinforcement (s) or mm 100
19 Number of Bar (n) Nos 116
20 Area of provided reinforcement (At) mm2 56941
21 Reinforcement (%) 0.815
*Shear Resistance
41 σ cp (subject to maximum of 0.2 fcd) MPa 0.7
42 K=1+Sqrt (200/d) <= 2 1.576
43
Concrete Shear capacity VRd.c =[0.12 K(80ρ1fck)0.33+(0.15σcp)]bwd KN 4612
3/2 1/2
44 Vmin= 0.031 K fck Mpa 0.388
45
Min Concrete Shear capacity VRd c min = (Vmin + 0.15 σcp) bw d KN 3446
46 Concrete Shear Capacity (Max of VRd.c,VRd.cmin ) KN 4612
47 ρ1=At/(bd) <= 0.02 0.008
48 Status ( If 0= Reinf. Not Reqd; for 1= Reinf Reqd.) 0
*Distribution Reinforcement (Cl. 16.6.1.1-IRC:112-2011) SAFE
0.7 M
2.125
2.75
2.125 0.2
Dimensions:
Outer dia of well = 7.00 m
Side of equivalent square = 6.20 m
Thickness of steining = 1.30 m
Inner dia of well = 4.40 m
Thickness of well cap = 1.50 m
Width of well cap = 0.7 m
Length of well cap = 7.00 m
Area of well cap = 38.5 Sqm
Cantilever Length = 3.3 m (From Autocad)
Width of well cap at cantilever tip= 5.1 m
Width of cap at support = 7.0 m (on conservative side)
Thickness of well cap = 1.5 m
LOAD CALCULATIONS:
Self weight of well cap = 74.7 t
Shear Force = 74.7 t
Bending Moment = 123.3 tm
LOAD CASE 2 : SLS Rare Combination (Wind Leading): Load Factor for DL 1
Vertical load on abutment shaft = 524.9 t
UDL = 749.88 t/m
SF = 2474.62 t
Bending Moment = 4083.1 tm
Total Bending Moment at support = -1073.0 tm
Total Shear Force at support = -1941.4 t
Torsion = 4472.2 tm
LOAD CASE 3 : ULS BasicCombination (Earth Pressure Leading Load Factor for DL 1.35
Vertical load on abutment shaft = 717.0 t
UDL = 1024.23 t/m
SF = 3379.94 t
Bending Moment = 5576.9 tm
Total Bending Moment at support = -1383.9 tm
Total Shear Force at support = -2581.7 t
Torsion = 6727.4 tm
LOAD CASE 4: ULS BasicCombination (Earth Pressure Leading 2): Load Factor for DL 1.00
LOAD CASE 5 : ULS BasicCombination (Live Load Leading 1): Load Factor for DL 1.35
Vertical load on abutment shaft = 761.0 t
UDL = 1087.16 t/m
SF = 3587.63 t
Bending Moment = 5919.6 tm
Total Bending Moment at support = -1041.2 tm
Total Shear Force at support = -2374.0 t
Torsion = 5263.0 tm
LOAD CASE 6: ULS BasicCombination (Live Load Leading 2): Load Factor for DL 1.00
Vertical load on abutment shaft = 613.3 t
UDL = 876.18 t/m
SF = 2891.38 t
Bending Moment = 4770.8 tm
Total Bending Moment at support = -385.4 tm
Total Shear Force at support = -1524.7 t
Torsion = 5263.0 tm
LOAD CASE 7 : ULS Seismic Combination (Seismic Leading 1): Load Factor for DL 1.35
Vertical load on abutment shaft = 543.4 t
UDL = 776.29 t/m
SF = 2561.74 t
Bending Moment = 4226.9 tm
Total Bending Moment at support = -2733.9 tm
Total Shear Force at support = -3399.9 t
Torsion = 6325.4 tm
LOAD CASE 8 : ULS Seismic Combination (Seismic Leading 1): Load Factor for DL 1.00
Vertical load on abutment shaft = 508.7 t
UDL = 726.76 t/m
SF = 2398.32 t
Bending Moment = 3957.2 tm
Total Bending Moment at support = -1198.9 tm
Total Shear Force at support = -2017.7 t
Torsion = 3724.1 tm
SUMMARY
MOMENT ( t- TORSION
SLS m) ( t-m) SHEAR FORCE (t)
ULS
Load Data
1 Moment KN-m
Material Data
2 Grade of Steel
3 Charecterstic strength of reinforcement (f yk) Table 18.1,IRC 112 MPa
4 Partial factor for steel (γs) Cl 6.2.2,IRC 112
5 Design value for tensile strength (fyd=fyk/γs) Cl 6.2.2,IRC 112 MPa
6 Modulus of Elasticity of Steel (ES) Cl 6.2.2,IRC 112 GPa
7 Grade of Concrete
8 Charecterstic compressive strength (fck) Table 6.5,IRC 112 MPa
9α Cl 6.4.2.8,IRC 112
10 Concrete material factor (γm) Cl 6.4.2.8,IRC 112
11 Design value for concrete compressive strength (fcd= αfck/γm) Cl 6.4.2.8,IRC 112 MPa
12 Modulus of Elasticity of Concrete (Ecm) Table 6.5,IRC 112 GPa
Geometric Data
13 Width of Slab/Beam (b) mm
14 Total depth of Slab/Beam (D) mm
15 Cover to Reinforcement ,face in contact with earth ( c ) mm
16 Dia of Reinforcement (φ) in first layer mm
17 Dia of Reinforcement (φ) in second layer mm
18 Effective depth of beam/Slab (d) mm
19 Spacing of Reinforcement (s) or mm
20 Number of Bar (n) Nos
21 Area of Reinforcement (At) mm2
22 Reinforcement (%)
Stress Check
23 Concrete Cross Sectional Area (AC) mm2
24 Perimeter in contact with atmosphere (u) mm
25 Notional Size (=2AC/u) mm
26 Age at Loading days
27 Relative humidity Table 6.9 , IRC 112 %
28 Final Creep Co-efficient of 28 days (φ) Table 6.9 ,IRC 112
29 Effective Modulus of Elasticity of Concrete (E eff) Cl 6.4.2.5,IRC 112 MPa
30 Modular ratio (m)
31 Allowable stress in Steel Cl 12.2.2,IRC 112 MPa
32 Allowable stress in Concrete Cl 12.2.2,IRC 112 MPa
33 Position of nuetral axis from comp. face (x) mm
34 MOA of Compression area mm2
35 MOA of Tension area mm2
36 Diff. mm2
37 MOI of cracked section mm4
38 Stress in tension reinf. MPa
39 Status
40 Stress in concrete MPa
41 Status
WELL CAP
-10149
Fe 500
500
1.150
434.783
200
M 40
40
0.670
1.500
17.867
33
3000
1000
75
25
0
925
115
26
12805
0.427
3000000
4000
1500.000
7.0
80
2.000
11000.0
18.182
400.0
19.20
309.2
1.43E+08
1.43E+08
0.000
1.18E+11
-964.228
O.K.
-26.625
O.K.
DESIGN OF WELL CAP BY BENDING THEORY (As per IRC 112:2011) ULS
At face of
S. No Type support
Load Data
1 Moment KN-m -10412
2 Shear Force VED KN -23740
3 Reduction factor b 1.000
4 Design Shear Force KN -23740
5 Axial force, NEd KN 0.0
Material Data
6 Charecterstic strength of reinf. (fyk) MPa 500
7 Partial factor for steel (γs) 1.150
8 Design yield strength of reinf. (fyd=fyk/γs) MPa 434.8
9 Modulus of Elasticity of Steel (ES) GPa 200.0
10 Charecterstic compressive strength of concrete (fck) MPa 40
11 α 0.670
Geometric Data
14 Width of Slab/Beam (b) mm 3000
15 Total depth of Slab/Beam (D) mm 1000
16 Cover to Reinforcement ( c ) mm 75
17 Dia of Reinforcement (φ) mm 25
18 Spacing of Reinforcement (s) or mm 115
19 Number of Bar (n) Nos 26
20 Area of provided reinforcement (At) mm2 12805
21 Reinforcement (%) 0.474
*Shear Resistance
41 σ cp (subject to maximum of 0.2 fcd) MPa 0.0
42 K=1+Sqrt (200/d) <= 2 1.471
45
Min Concrete Shear capacity VRd c min = (Vmin + 0.15 σcp) bw d KN 945
46 Concrete Shear Capacity (Max of VRd.c,VRd.cmin ) KN 1170
47 ρ1=At/(bd) <= 0.02 0.005
48 Status ( If 0= Reinf. Not Reqd; for 1= Reinf Reqd.) 0
49 v=0.6(1-fck/310) MPa 0.523
Maximum shear capacity of section V ED KN 12611.6
50
<= 0.5*bw*d*v*fcd
OK
51 Balance shear force (VED - VRd.c) KN 0
52 Dia of Shear Reinforcement (φs) mm 12.0
53 Number of Legs Nos 8.0
54 Spacing of Reinforcement (s) or mm 240
55 Area of Shear Reinforcement (ASW) mm2
68 Status O.K
TORSION CHECK IN WELL CAP
S.no Unit
Load Data
1 Torsional Moment TED KN-m 67274
2 Shear Force on bearing VED KN -25817
Material Data
3 Grade of Steel Fe 500
4 Charecterstic strength of reinforcement (fyk) MPa 500
5 Partial factor for steel (γs) 1.15
6 Design value for tensile strength (fyd=fyk/γs) MPa 434.783
7 Modulus of Elasticity of Steel (ES) GPa 200
8 Grade of Concrete M 40
9 Charecterstic compressive strength (fck) MPa 40
10 fctm MPa 2.80
11 α 0.67
12 Concrete material factor (γm) 1.50
13 Design value for concrete compressive strength (fcd= αfck/γm) MPa 17.867
Geometric Data
14 Width of Slab/Beam (b) mm 3000
15 Total depth of Slab/Beam (D) mm 1000
16 Cover to Reinforcement ,face in contact with earth ( c ) mm 75
Dia of Main Reinforcement (φ) mm 25
Effective depth (d) mm 900.5
Torsional Resistance
17 A=Total area of cross section mm2 3000000
18 U=Outer Perimeter of cross section mm 8000
19 tef.i= (A/U) 375
20 It should not be less than (tef,i > 2x(D+C+φ/2+φs)) 199
21 Ak= Area of hollow core mm2 1640625
22 Torsional shear stress Tt.i = (TED/(2 x AK x tef,i) Mpa 54.67
23 Considering Zi= mm 625
24 VED.i=Design Torsional Shear Force (Tt.i x tef,i x zi) KN 12814
25 Total shear force (including Torsional S.F) KN -13003
26 v 0.523
27 αcw 1
θ 21.8
sin θ 0.371
cos θ 0.928
28 cot θ 2.5
29 z =(0.9d) mm 810.5
30 v1 0.523
31 TRd.max (Design torsional resistance moment) KN-m 3961
32 VRd.max (Max design shear resistance) KN 7828
33 TED/TRd.max+VED/VRd.max= 13.68
34 Section Capacity Status Not OK
35 Uk is the perimeter of the area Ak 6500
36 Req. cross sectional area of the longitudnal reinf. for torsion ΣAsl cm2/m 1179.0
37 Dia of Longitudinal Reinforcement (φ) 20
38 Spacing of Reinforcement (s) or c/c 120
40 Total area provided cm2/m 26.2
41 Status Not OK
42 Design yeild strength of shear reinf (fywd =0.8fyk/gs) Mpa 348
43 Dia of Shear Reinforcement (φs) mm 12
44 Spacing of Reinforcement (s) or mm 220
45 Number of Legs Nos 8
46 Area of shear reinf (Asw) mm2 905
47 Steel shear capacity VRd.s KN 2899
48 Status OK
49 Max shear capacity VRd.max KN 7828
50 Status OK
Earth Pressure Calculation For Design of Dirt Wall & Abutment Shaft:
3.34M
0.35 m
Multplying 7.90M
factor for 9.40M
dynamic
incriment
3.80
WELL CAP
0.671 5.25 257.50
1.2Kag Kagh
DIRT WALL:
=
Live Load Surcharge:
Force = 2.2 t/m
Lever Arm (0.5H) = 1.67 m
Moment at base of dirt wall = 3.7 tm/m
LOAD COMBINATIONS
Seismic Combination :
Factor H (t/m) M (tm/m)
LL Surcharge 0.2 0.45 0.75
Active Er Pr 1 3.12 4.37
Total 3.56 5.12
DESIGN OF DIRT WALL SLS
Load Data
1 Moment KN-m
Material Data
2 Grade of Steel
3 Charecterstic strength of reinforcement (f yk) Table 18.1,IRC 112 MPa
4 Partial factor for steel (γs) Cl 6.2.2,IRC 112
5 Design value for tensile strength (fyd=fyk/γs) Cl 6.2.2,IRC 112 MPa
6 Modulus of Elasticity of Steel (ES) Cl 6.2.2,IRC 112 GPa
7 Grade of Concrete
8 Charecterstic compressive strength (fck) Table 6.5,IRC 112 MPa
9α Cl 6.4.2.8,IRC 112
10 Concrete material factor (γm) Cl 6.4.2.8,IRC 112
11 Design value for concrete compressive strength (fcd= αfck/γm) Cl 6.4.2.8,IRC 112 MPa
12 Modulus of Elasticity of Concrete (Ecm) Table 6.5,IRC 112 GPa
Geometric Data
13 Width of Slab/Beam (b) mm
14 Total depth of Slab/Beam (D) mm
15 Cover to Reinforcement ,face in contact with earth ( c ) mm
16 Dia of Reinforcement (φ) in first layer mm
17 Dia of Reinforcement (φ) in second layer mm
18 Effective depth of beam/Slab (d) mm
19 Spacing of Reinforcement (s) or mm
20 Number of Bar (n) Nos
21 Area of Reinforcement (At) mm2
22 Reinforcement (%)
Stress Check
23 Concrete Cross Sectional Area (AC) mm2
24 Perimeter in contact with atmosphere (u) mm
25 Notional Size (=2AC/u) mm
Age at Loading days
Relative humidity Table 6.9 , IRC 112 %
26 Final Creep Co-efficient of 28 days (φ) Table 6.9 ,IRC 112
27 Effective Modulus of Elasticity of Concrete (E eff) Cl 6.4.2.5,IRC 112 MPa
28 Modular ratio (m)
29 Allowable stress in Steel Cl 12.2.2,IRC 112 MPa
30 Allowable stress in Concrete Cl 12.2.2,IRC 112 MPa
31 Position of nuetral axis from comp. face (x) mm
32 MOA of Compression area mm2
32 MOA of Tension area mm2
33 Diff. mm2
34 MOI of cracked section mm4
35 Stress in tension reinf. MPa
36 Status
37 Stress in concrete MPa
38 Status
DIRT WALL
74
Fe 500
500
1.150
434.783
200
M 40
40
0.670
1.500
17.867
33
1000
350
50
12
0
300
125
8
905
0.259
350000
1350
518.519
7.0
80
2.000
11000.0
18.182
400.0
19.20
84.3
3.55E+06
3.55E+06
0.000
9.65E+08
299.325
O.K.
6.429
O.K.
DESIGN OF DIRT WALL BY BENDING THEORY (As per IRC 112:2011) ULS
At face of
S. No Type support
Load Data
1 Moment KN-m 110
2 Shear Force VED KN 74
3 Reduction factor b 1.000
4 Design Shear Force KN 74
5 Axial force, NEd KN 0.0
Material Data
6 Charecterstic strength of reinf. (fyk) MPa 500
7 Partial factor for steel (γs) 1.150
8 Design yield strength of reinf. (fyd=fyk/γs) MPa 434.8
9 Modulus of Elasticity of Steel (ES) GPa 200.0
10 Charecterstic compressive strength of concrete (fck) MPa 40
11 α 0.670
Geometric Data
14 Width of Slab/Beam (b) mm 1000
15 Total depth of Slab/Beam (D) mm 350
16 Cover to Reinforcement ( c ) mm 50
17 Dia of Reinforcement (φ) mm 12
18 Spacing of Reinforcement (s) or mm 125
19 Number of Bar (n) Nos 8
20 Area of provided reinforcement (At) mm2 905
21 Reinforcement (%) 0.319
*Shear Resistance
41 σ cp (subject to maximum of 0.2 fcd) MPa 0.0
42 K=1+Sqrt (200/d) <= 2 1.839
68 Status O.K
DESIGN OF CANTILEVER WING WALL SLS
Load Data
1 Moment KN-m
Material Data
2 Grade of Steel
3 Charecterstic strength of reinforcement (f yk) Table 18.1,IRC 112 MPa
4 Partial factor for steel (γs) Cl 6.2.2,IRC 112
5 Design value for tensile strength (fyd=fyk/γs) Cl 6.2.2,IRC 112 MPa
6 Modulus of Elasticity of Steel (ES) Cl 6.2.2,IRC 112 GPa
7 Grade of Concrete
8 Charecterstic compressive strength (fck) Table 6.5,IRC 112 MPa
9α Cl 6.4.2.8,IRC 112
10 Concrete material factor (γm) Cl 6.4.2.8,IRC 112
11 Design value for concrete compressive strength (fcd= αfck/γm) Cl 6.4.2.8,IRC 112 MPa
12 Modulus of Elasticity of Concrete (Ecm) Table 6.5,IRC 112 GPa
Geometric Data
13 Width of Slab/Beam (b) mm
14 Total depth of Slab/Beam (D) mm
15 Cover to Reinforcement ,face in contact with earth ( c ) mm
16 Dia of Reinforcement (φ) in first layer mm
17 Dia of Reinforcement (φ) in second layer mm
18 Effective depth of beam/Slab (d) mm
19 Spacing of Reinforcement (s) or mm
20 Number of Bar (n) Nos
21 Area of Reinforcement (At) mm2
22 Reinforcement (%)
Stress Check
23 Concrete Cross Sectional Area (AC) mm2
24 Perimeter in contact with atmosphere (u) mm
25 Notional Size (=2AC/u) mm
Age at Loading days
Relative humidity Table 6.9 , IRC 112 %
26 Final Creep Co-efficient of 28 days (φ) Table 6.9 ,IRC 112
27 Effective Modulus of Elasticity of Concrete (E eff) Cl 6.4.2.5,IRC 112 MPa
28 Modular ratio (m)
29 Allowable stress in Steel Cl 12.2.2,IRC 112 MPa
30 Allowable stress in Concrete Cl 12.2.2,IRC 112 MPa
31 Position of nuetral axis from comp. face (x) mm
32 MOA of Compression area mm2
32 MOA of Tension area mm2
33 Diff. mm2
34 MOI of cracked section mm4
35 Stress in tension reinf. MPa
36 Status
37 Stress in concrete MPa
38 Status
WELL CAP
90
Fe 500
500
1.150
434.783
200
M 40
40
0.670
1.500
17.867
33
1000
300
50
12
0
250
100
10
1131
0.377
300000
1300
461.538
7.0
80
2.000
11000.0
18.182
400.0
19.20
82.9
3.44E+06
3.44E+06
0.000
7.64E+08
357.865
O.K.
9.765
O.K.
DESIGN OF CANTILEVER WING WALL BY BENDING THEORY (As per IRC 112:2011) ULS
At face of
S. No Type support
Load Data
1 Moment KN-m 135
2 Shear Force VED KN 62
3 Reduction factor b 1.000
4 Design Shear Force KN 62
5 Axial force, NEd KN 0.0
Material Data
6 Charecterstic strength of reinf. (fyk) MPa 500
7 Partial factor for steel (γs) 1.150
8 Design yield strength of reinf. (fyd=fyk/γs) MPa 434.8
9 Modulus of Elasticity of Steel (ES) GPa 200.0
10 Charecterstic compressive strength of concrete (fck) MPa 40
11 α 0.670
Geometric Data
14 Width of Slab/Beam (b) mm 1000
15 Total depth of Slab/Beam (D) mm 300
16 Cover to Reinforcement ( c ) mm 50
17 Dia of Reinforcement (φ) mm 16
18 Spacing of Reinforcement (s) or mm 125
19 Number of Bar (n) Nos 8
20 Area of provided reinforcement (At) mm2 1608
21 Reinforcement (%) 0.693
*Shear Resistance
41 σ cp (subject to maximum of 0.2 fcd) MPa 0.0
42 K=1+Sqrt (200/d) <= 2 1.928
68 Status O.K
ANNEXURE -1
STAAD FILES