Dams
Dams
Dams
They are much thicker at the base than the and design of the dam. Buttress dams are 2. Wind pressure
6
𝑅𝑦 6𝑒
top – a shape that reflects the distribution sometimes called hollow dams because 3. Wave Action 𝑞= − (1 ± )
the buttresses do not form a solid wall 𝐵 𝐵
of the forces of the water against the dam. 4. Floating bodies Note: Use (+) to get the stress at point where
As water becomes deeper, it exerts more stretching across a river valley 5. Earthquake Load Ry is nearest. In the diagram shown above, use
horizontal pressure on the dam. Gravity ANALYSIS OF GRAVITY DAMS III. Solve For Reaction (+) to get qT and (-) to get qH. A negative stress
dams are relatively thin near the surface of A dam is subjected to hydrostatic force due A. Vertical Reaction, Ry indicates compressive stress and a positive
the reservoir, where the water pressure is to water which raised on its upstream side. stress indicates tensile stress.
𝑅𝑦 = ∑ 𝐹𝑣
light. A thick base enables the dam to These forces cause the dam to slide horizontally 𝐵
B. Horizontal Reaction, Rx CASE II: 𝑒≥
withstand the more intense water pressure on its foundation and overturn it about its 6
at the bottom of the reservoir. Since soil cannot carry any tensile stress, the
downstream edge or toe. These tendencies are 𝑅𝑥 = ∑ 𝐹ℎ
2. Embankment Dam is a gravity dam result of the previous equation is invalid if the
resisted by friction on the base of the dam and IV. Moment about the Toe
formed out of loose rock, earth, or stress is positive. This will happen if e>B/6.
gravitational forces which causes a moment A. Righting Moment, RM (rotation towards
combination of these materials. The Should this happen use the following equation
opposite to the overturning moment. The dam the upstream side)
upstream and downstream slopes of may also be prevented from sliding by keying its 2𝑅𝑦
embankment dams are flatter than those base. 𝑅𝑀 = ∑ 𝑠𝑡𝑎𝑏𝑖𝑙𝑖𝑧𝑖𝑛𝑔 𝑚𝑜𝑚𝑒𝑛𝑡𝑠 𝑞𝑐 =
3𝑥̅
1. The section of concrete gravity dam is shown. Unit weight of concrete is 24 KN/m3. Hydrostatic uplift pressure varies
linearly from heel to toe. Coefficient of friction between the base of the dam and the foundation is 0.8.
4m
9m
3m
9m