Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ADRE Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

ADRE* Sxp/408 DSPi

Bently Nevada* Asset Condition Monitoring

Description
ADRE* Sxp Software and the 408 DSPi (Dynamic Signal Processing Instrument)
make up a highly scalable system for multi-channel signal processing and data
acquisition.
Unlike other general-purpose computer-based data acquisition systems, ADRE
Sxp and the 408 DSPi are specifically designed for real-time highly parallel signal
processing and presentation. This extremely versatile system incorporates the
functionality of many types of instrumentation, such as oscilloscopes, spectrum
analyzers, filters, signal conditioners, and digital recorders into a single platform.
The system is designed specifically for secure corporate network environments,
allowing it to operate remotely across a LAN/WAN, or store data in full “stand-
alone” mode without an additional/external computer. Additional equipment is
seldom, if ever, needed. The system’s real-time display capability permits it to
continuously display data independently of data being stored to permanent
memory. For established ADRE system users, ADRE Sxp also supports all previous
ADRE for Windows databases.

An ADRE Sxp data acquisition system consists of:


 408 Dynamic Signal Processing Instrument(s)
 ADRE Sxp client software, ADRE Quick Configuration software
 A computer system capable of running ADRE Sxp software.

The 408 DSPi is fully portable or can be rack mounted allowing convenient
operation in test stands, on-site, or at remote locations. The 408 DSPi’s highly
configurable design supports virtually all standard and non-standard input types
including both dynamic transducer signals (such as those from proximity probes,
velocity transducers, accelerometers, force hammers, dynamic pressure
sensors), and static signals (such as process variables from transmitters and
distributed control systems). For rotating machinery applications, users can
provide a Keyphasor* or other speed input signal (such as that from a magnetic
or optical transducer) to drive synchronous sampling and order tracking. For
structural analysis needs, impact testing using force hammers is supported. The
system also supports multiple triggering modes for automated data acquisition,
allowing you to use the system as a data or event logger without an operator
present.

The Client-Server architecture allows multiple software clients to operate and


simultaneously view data from single/multiple 408 DSPi systems simultaneously,
permitting users to independently view data in the fundamental measurement
units of their choice. Software installation and configuration are quick and easy,
allowing mass configuration of multiple channels with minimal user intervention.
Configuration templates and software further simplify the process, allowing the
user to install the software, produce a configuration, and begin capturing data in
minutes.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 1 of 31
408 DSPi Overview The sampling card can provide a variety of data
Each 408 DSPi supports up to 4 sampling cards for depending on the configuration and user needs.
up to 32 channels of data acquisition. The 408 DSPi Each channel can provide multiple “static” variables
base system uses internal clocks and simulated including:
speed/Keyphasor signals to support both  direct amplitude,
asynchronous and synchronous sampling for all
 bandpass amplitude
channels. Speed Input/Trigger cards support up to 3
 1X and 2X Amplitude and Phase, and up to 4
independent speed input channels for external
additional user defined nX vectors including
speed inputs. Each Speed Input/Trigger card uses 1
amplitude and phase
available slot, and the 408 DSPi can use a maximum
of 2 Speed Input/Trigger cards simultaneously  average & instantaneous gap or bias
providing up to 6 physical speed inputs and 6 voltages
simulated speed inputs. The user can assign any  multiple speed values, and
speed input (KPH) to any channel in a 408 DSPi. Most  a date/time stamp.
signal processing and sampling parameters can be
changed “on-the-fly” without interrupting data In addition to the static data, each channel can
collection. provide up to 4 user-defined dynamic waveforms.
Users can configure waveforms for simultaneous
The 408 DSPi architecture provides flexible hardware Synchronous and/or Asynchronous sampling, with
configuration. Users can insert sampling cards into different sampling rates and/or frequency spans.
the chassis as required. Slots 1 through 4 support all The sampling card supports up to 2 different
standard sampling cards. Slot 5 is intended synchronous sampling rates simultaneously. Time-
specifically for the Digital Replay card as well as Synchronous Averaging can also be enabled for all
future option cards. synchronous waveforms. In addition, the card can
also sample and store the raw time-continuous data
The standard Dynamic Sampling and Speed for each channel. All channels within the system are
Input/Trigger cards provide full support for structural always sampled simultaneously, are synchronized,
analysis and impact testing. Data can be analyzed and are initiated based on a set of user defined
natively or exported to 3rd party applications if events.
desired.
3-Ch Speed Input/Trigger Card (168906 – AA)
The 408 DSPi front panel controls and displays basic
functions and data. Users can directly initiate The 3-channel speed input/trigger card supports a
manual samples and triggering from the front panel variety of transducer inputs and signal conditioning
without using ADRE Sxp software. The front panel needs including; proximity, magnetic, optical, and
LEDs indicates sampling and trigger status and laser pickups. Transducer power for both optical
activity. Users can download multiple sampling pickup and ± 24Vdc proximity is also available if
configurations to the 408 DSPi and later select them needed. For impact testing applications, the force
for use from the front panel. hammer output can be connected directly to this
card providing level triggering and full dynamic
waveform capture. The card integrates a rich set of
configurable analog signal conditioning tools
8-Channel Dynamic Sampling Card (168905 – AA)
including: input gain, voltage clamping, inversion,
The 8-channel dynamic sampling card is an rising or falling edge trigger, auto/manual threshold,
extremely powerful and flexible signal processing and hysteresis. The user can associate a
engine. Along with the analog front-end programmable speed input (Keyphasor)
conditioning, the user can configure most multiplier/divider for each channel independently,
transducer inputs, with positive or negative bias, define discrete values for events per revolution, or, a
while maintaining maximum signal input range. An final ratio, whichever is more convenient. Each
array of DSP processors and 24-bit ADCs provide channel can have up to three separate “stages” of
maximum resolution. Input signals can be either AC multiplier/divider ratios. Trigger/speed input
or DC coupled, and users can independently define channels provide full dynamic sampling, complete
upper and lower input voltage levels along with full- with static and waveform data, available for real-
scale range and transducer scale factor. time viewing and storage. Each channel also

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 2 of 31
includes a buffered output, allowing the user to eight constant current transducer systems. Field
select either raw, conditioned analog, or TTL outputs. connection cable and adapter accessories
The buffered outputs are independent of the signal accommodate additional transducer connections.
being used for processing. In addition to ± 24 Vdc selections, the card provides
± positive and negative bias selections for constant
Digital Replay Card (168907 – AA – BB - CC) current applications, all of which can be used
The Digital Replay Card provides simultaneous simultaneously, to provide a highly flexible power
synchronous and asynchronous internal digital source for most any need. Users can configure
reprocessing and playback of all channels in the transducer power bias in blocks of four (4) directly
408DSPi. The replay card maintains exceptional from the card without the need for special tools,
accuracy and precision in the signal reprocessing jumpers, or software.
that far surpasses the capabilities of other
equipment and reprocessing techniques. The digital Each output provides individual short-circuit
replay card can play back raw data for all channels protection, current regulation, and indicators for
simultaneously including Keyphasor/speed and power status and voltage/current selection
dynamic sampler inputs. Users can modify all (complete card status is provided within ADRE Sxp
sampling parameters on a KPH channel when client software). Also, this card can occupy a
replayed, and fully manage and re-condition the dedicated option slot and leave all transducer input
gain, inversion, clamping, and other characteristics slots available.
of Keyphasor signals. This provides the ability to
control triggering edges and thresholds as Field wiring cable accessories allow the user to
reprocessing and analysis requires. On standard conveniently connect both power and signals to the
dynamic channels, users can modify most sampling 408DSPi. These accessories support most voltage
parameters. As an example, users may add or and constant current transducer applications
modify waveform assignments, variable generation, without the need for additional bulky equipment.
filtering options, frequency span, and Keyphasor Field wiring accessories and cables must be ordered
assignments that did not exist in the original separately.
configuration reprocessing the data. Additionally,
users may add or modify all sampling criteria and
triggering parameters. Full scale range, coupling,
and transducer type cannot be altered for standard
dynamic channels. The Digital Replay card occupies
Slot #5 of the 408 DSPi and does not reduce the
number of channels available for data collection.

With the addition of Analog Output Replay Card the


user may send up to 32 channels of recorded signals
through data ports to auxiliary equipment. These
signals are analog recreations of the original data
observed by ADRE. The Replay Module can be
ordered with or without the Analog Output Replay
Card. Existing Replay Cards can be modified to
include the Analog Output feature by sending the
cards to Product Repair at Bently Nevada.

Transducer Power Supply Card (168908 – AA – BB)


The transducer power supply card provides power
for a wide variety of displacement, velocity,
acceleration including ICP accels, force hammers,
and other transducer types used in field and test
stand applications. This card can simultaneously
power up to 32 transducers in various combinations,
and provides direct physical connections for up to 16
transducers, eight ± 24 Vdc transducer systems and
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 3 of 31
Networking Overview
Signal Conditioning - General
The 408 DSPi is a secure network appliance that 8 Channel Dynamic Sampling Card
supports DHCP or fixed IP addressing based on your
Slot Position
network environment needs. When installed on a
LAN/WAN in DHCP mode, the DHCP server or router Slots 1 through 4
will assign an IP address to the 408 DSPi. When the
user makes a direct connection between the 408 24 Bit A/D
DSPi and client computer in DHCP mode, an IP converters
address will be automatically assigned. The 408 DSPi
also supports fixed IP addressing. The user can
Input
assign a fixed IP address on one Ethernet port while
Impedance
simultaneously running DHCP on the second
Ethernet port. In some instances, primarily when Single Ended
navigating corporate security infrastructures, 742kΩ
firewalls, or VPNs (Virtual Private Networks), specific
router configuration may be necessary. Contact your Differential
local product support representative for details 1.484 MΩ between sig+ and sig- 4-
specific to your needs. 20 mA 511Ω

Specifications
Inputs
408 DSPi
Single-ended
8
Typical specifications are
provided for a temperature of Differential
+25 C ± 3 C (+77 F ± 5.4 F ) 4
except where noted. 4-20 mA
Data Storage 8
Capacity
Internal - 300GB or 600GB Maximum
Signal Input
Range:
Communication:
-25 to 25 V
Dual 1000/100Mb RJ45 Ethernet
Ports
AC Configurable
Protocol - TCP/IP
Full Scale Range
DHCP or Fixed IP addressing
0.7 to 10 V
LAN/WAN compatible
Internal Clock:
DC Configurable
Battery-Backed Real-Time clock
Full Scale Range
(RTC) accuracy is ± 2 seconds /
month 0.35 to 50 V

Status
Indication
Boot, Selftest, OK/Not OK, Activity,
A/D over range

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 4 of 31
Direct Measurement Accuracy Acceleration DC
Coupled Low
Filter values @ 0 db points unless specified Mode
otherwise.
3 Hz to 50 kHz
Non-RMS, Non- 2
Integrated ± 1% of Full Scale Range
Amplitude Velocity DC
Coupled Low
AC Coupled – Mode
Hi Mode
3 Hz to 50 kHz
1.6 Hz to 50 kHz
2 (-3db @ 3Hz )
± 1.25% of Full Scale Range 2
± 1% of Full Scale Range
AC Coupled -
Low Mode
N/A Non-RMS
Integrated, RMS
DC Coupled – Integrated
Hi Mode Amplitude
1 Hz to 50 kHz Acceleration AC
2
± 1% of Full Scale Range Coupled Hi
± .011V below 1 V pp Mode
DC Coupled - 10 Hz to 20 kHz
2
Low Mode ± 1% of Full Scale Range
0.167 Hz to 20 kHz
2
± 1% of Full Scale Range Velocity AC
± .011V below 1 V pp Coupled Hi
Mode
3 Hz to 20 kHz
Non-Integrated, ± 1% of Full Scale Range
2

RMS Amplitude
Direct
Acceleration Measurement
AC/DC Coupled Update Rates
Hi Mode Valid KPH or
10 Hz to 50 kHz Simulated KPH
2
± 1% of Full Scale Range present
Velocity 0 to Peak / Peak to Peak values
updated every 4 KPH periods.
AC/DC Coupled
Hi Mode Invalid KPH or
No KPH present
10 Hz to 50 kHz
2 High Mode – 2 sec sliding window
± 1% of Full Scale Range
Low Mode – 12 sec sliding window
AC Coupled
Low Mode 100ms update rate
N/A Integrated
Values
High Mode – 2 sec sliding window
Low Mode – 2 sec sliding window
100ms update rate

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 5 of 31
Bandpass Measurement Accuracy Bandpass
Measurement
Specifications are exclusive of filter corner Update Rates
settings and transition regions. Filter values
specified @ -3 db points. Valid KPH or
Non-RMS, Non- Simulated KPH
Integrated present
Amplitude 0 to Peak / Peak to Peak values
updated every 4 KPH periods.
1 Hz to 50 kHz
2 Invalid KPH or
± 1% of Full Scale Input No KPH present
100ms update rate
Non-RMS Integrated
Integrated, RMS
Integrated 2 sec sliding window
Amplitude Non-Integrated
1 Hz to 20 kHz 2 sec sliding window
2
± 1% of Full Scale Input
Filtered
Measurements
Bandpass Filter
Selections Filter
(Typical) Bandwidth
Selectable
Butterworth
1.2 cpm, 12 cpm, 120 cpm
2 Pole ( -40 db/decade )
(0.02 Hz, 0.2 Hz, 2 Hz)
4 Pole ( -80 db/decade )
User enabled
6 Pole ( -120 db/decade ) Auto-switching
8 Pole ( -160 db/decade ) tracking filters
Range transition
High Pass 1 Hz to 25.5kHz 120 cpm < to > 12 cpm @ 600
Low Pass 10 Hz to 50kHz rpm
Min separation between 12 cpm < to > 1.2 cpm @ 60 rpm
HPF and LPF Filter Settling
Time to 95 / 99
2 Pole – 10.24 x HPF % of final value
4 Pole - 3.24 x HPF 120 cpm < 0.477 / .796 sec
6 Pole - 2.25 x HPF 12 cpm < 4.77 / 7.96 sec
8 Pole – 1.96 x HPF 1.2 cpm < 47.7 / 79.6 sec
Options nX Amplitude
HPF < 10 Hz ( 2 Pole ) and Phase
HPF ≥ 10 Hz ( 2, 4, 6, 8 Pole) Accuracy
LPF ≥ 10 Hz ( 2, 4, 6, 8 Pole) 1 to 120k rpm
2
-3db Corner ± 1% of Full Scale Range
Frequencies ± 3˚ of Input (Steady State)
HPF & LPF - 1 Hz Increments, nX Resolution
-3db ± 5% and Range
0.01X Increments
0.01X to ((sample/rev)/2-1)X
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 6 of 31
Below Minimum Measurement
Amplitude Range
DC Coupled -25 to 25 Vdc ( Upper and Lower
≤ 0.015 Vpp voltage range fully
AC Coupled programmable)
≤ 0.5% of full scale Amplitude
± 0.12% of FSR @ 25V
Gap Voltage ± 0.30% of FSR @ 10V
Measurements ± 0.75% of FSR @ 1-5V
Measurement (FSR = Full Scale Range)
Ranges Resolution
0 V to 24 Vdc 152.588 µV ( 0 to 10 Vdc )
-24 V to 0 Vdc 61.035 µV ( 1 to 5 Vdc )
-12 to 12 Vdc Response to
-24 to 24 Vdc 95%/99% of
Final Value
Upper and Lower voltage range
fully programmable between -25 0.95 / 1.59 sec.
to 25 Vdc Low-pass filter
Amplitude -3db ± 5% @ 0.5 Hz
± 0.17% of FSR @ -25 to 25 V
± 0.26% of FSR @ 0 to ± 25 V 4 – 20 mA Input
± 0.26% of FSR @ -12.5 to 12.5 V Input Range
(FSR = Full Scale Range) 0 - 41.6 mA max
Resolution Amplitude
Measured 366.2 µV @ 24 V FSR ±1% of Full Scale Input
Response to Resolution
95%/99% of
244 nA / bit
Final Value
Response to
Instantaneous
95%/99% of
Gap
Final Value
0.95 / 1.59 sec.
5.3 / 8.84 sec
-3db ± 5% @ 0.5 Hz
Low-pass filter
Average Gap
-3db ± 5% @.09 Hz
5.3 / 8.84 sec,
-3db ± 5% @ .09 Hz
Dynamic Waveform
Data
Process Variable
Measurements Filtering associated with
asynchronously sampled dynamic
Voltage Inputs waveform data specific to anti-
0 to 10 Vdc ( Typical ) alias filters. Synchronously
1 to 5 Vdc ( Typical ) sampled waveform data is not
anti- alias filtered.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 7 of 31
Asynchronous DC Frequency
Sampling Rates Support
128 to 128kHz ( 2.56 x Frequency 937 rpm (15.62Hz) @ 2048x
Span, 50, 100, 250, 500, 1k, 2.5k, 1.87k rpm (31.25Hz) @ 1024x
5k, 10k, 25k, 50k Hz )
2.66k rpm (44.4Hz) @ 720x
Anti-Alias
3.75k rpm (62.5Hz) @ 512x
-80 db Minimum
5.3k rpm (88.8Hz) @ 360x
AC Coupled
7.5k rpm (125Hz) @ 256x
1 Hz to 50 kHz
15k rpm (250Hz) @ 128x
Amplitude
2
30k rpm (500Hz) @ 64x
±1% of Full Scale Range
60k rpm (1kHz) @ 32x
Phase
120k rpm (2kHz) @ 16x
±3˚ of Input
(AC Frequency support from 1 Hz)
DC Coupled
Output
DC Hz to 50 kHz
Up to 2 simultaneous
Amplitude synchronous waveforms per
2
±1% of Full Scale Range channel
Phase Hardware Generated
±3˚ of Input Spectra
Output Spectral Lines
Up to 4 simultaneous 6400, 3200, 1600, 800, 400, 200,
asynchronous waveforms per 100 lines, selectable. One
channel asynchronous spectrum per
Synchronous channel.
Sampling Rates Windowing provided on spectrum
Samples/rev (16, 32, 64, 128, 256, up to 800 lines, Rectangular,
360, 512, 720, 1024, 2048) Hanning, Flat-Top, Exponential
Synch sample rate X rpm ≤ 32 Free Running
kHz Spectrum
Hardware Generated 1 per channel
Time Synchronous Zoom Spectrum
Averaging 1 asynchronous spectrum per
Up to 2048 samples per channel.
waveform, up to 512 Averages Center
i.e. (8 revs @ 256 samples/rev), Frequency
(4 revs @ 512 samples/rev) Configurable in 1 Hz increments
Zoom Factors
2, 5, 10, 20, 50
Spectral Lines
100, 200, 400, 800

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 8 of 31
2
Note : Dynamic Sampling Card Amplitude vs. Inputs
Frequency Cumulative Error
Total Inputs
Frequency dependent amplitude 3 speed inputs per card (single
and phase errors added to fixed ended), maximum 2 cards per
range specifications. system.
Amplitude Supported
error vs. Transducers
frequency
Proximity, magnetic, or optical
0 % from 0 to 10kHz transducers. One “powered”
(± 4) % from 10kHz to 50kHz optical input (Channel 3 only)
Phase error vs. Proximity inputs
frequency Input Range
(-0.5) to (-2.8) deg from 0 to 5kHz -25 to +25 Vdc
(-2.8) to (-6.6) deg from 5kHz to Coupling
10kHz
AC or DC
Input
Impedance
Keyphasor*/Speed Measurements:
128.9 kΩ

3 Channel Speed Input (KPH) / Trigger Dynamic


Sampling Card Buffered
Transducer
Outputs
Slot Position
3 channels, user selectable output
Slots 1 through 4
Output Types
Raw, Analog Conditioned, TTL
Accuracy
± 22V output maximum
1 – 120k rpm, (+/- 0.00915)% of 20 µS min duty cycle for TTL
Period Input, (+/- 11) rpm @ 120k output
rpm Input
Output
Impedance
Simulated 330Ω
Keyphasor
Accuracy Output Drive
Capacitance
1 – 120k rpm (+/- 0.02) % of 6100 pf (min)
Period Input
Load Resistance
Note: Keyphasor card not
required to provide simulated ≥ 10k Ω
Keyphasor (up to 6 simulated Output
Keyphasors) Protection
Short circuit protected

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 9 of 31
Raw Outputs Direct
Amplitude and Measurement
Delay (KPH) Accuracy
AC Error Filter values specified @ 0 db
-0.91% to 0.42% points
DC Error Non-RMS, Non -
Integrated
± 60 mV
Amplitude
Signal Delay
AC Coupled -
0.6 µS (0.43 deg @ 2kHz)
High Mode
Conditioned
1.6 Hz to 20 kHz
Outputs 3
Amplitude and ± 1.25% of Full Scale Range
Delay AC Coupled -
AC Error Low Mode
-1.05% to 0.39% N/A
DC Error DC Coupled -
High Mode
- 0.35 V to +60 mV
1 Hz to 20 kHz
Signal Delay 3
± 1% of Full Scale Range
2.0 µS ( 4.0 µS Optical ) (1.4/2.8
deg @ 2kHz) ± .011V below 1 V pp
DC Coupled -
Low Mode
Transducer
Power 0.167 Hz to 20 kHz
3
± 1% of Full Scale Range
-24 Vdc, 57.6 mA max (-22.77 Vdc
max, -24.48 Vdc min) ± .011V below 1 V pp
+24 Vdc, 29 mA max (+24.48Vdc
max, +23.13Vdc min) Bandpass
+5 Vdc, 250 mA max (+5.2 Vdc Measurement
max, +4.25 Vdc min, optical (KPH) Accuracy
transducer power, Channel 3 only) Specifications are exclusive of
filter corner settings and
transition regions. Filter values
for bandpass specified @ -3 db
points
Non-RMS, Non -
Integrated
Amplitude
1 Hz to 20 kHz
3
± 1% of Full Scale Range

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 10 of 31
Gap Voltage Keyphasor
(KPH) Index
Measurements While the shaft is stopped, the
Measurement Keyphasor Index is used to assist
Range with positioning a shaft relative to
a reference position. Manual
0 to 25 Vdc
threshold must be selected for
-25 to 0 Vdc speeds below 1 rpm.
-12.5 to 12.5 Vdc Triggering
-25 to 25 Vdc Automatic or Manual Mode
Amplitude Selectable, positive or negative
± 0.20% of FSR @ -25 to 25 V edge of signal input.
± 0.28% of FSR @ 0 to ± 25 V Speed/Dynamic
± 0.28% of FSR @ -12.5 to 12.5 V Frequency
Range
(FSR = Full Scale Range)
DC Coupled: DC to 20kHz
Resolution
AC Coupled: 1Hz to 20kHz
Measured 381.47 µV @ 25 V
Auto
range
Threshold
Response to
1 rpm – 120k rpm (0.0167 Hz –
95%/99% of
2kHz), min voltage required at low
Final Value
freq
Instantaneous
Manual
Gap
Threshold
0.95 / 1.59 sec.
1 rpm to 120k rpm (0.0167 Hz to
-3db ± 5% @ 0.5 Hz 2kHz) -25 Vdc to 25 Vdc, 0.10 Vdc
Average Gap increments
5.3 / 8.84 sec, Input Clamping
-3db ± 5% @ .09 Hz -25 to 25 Vdc, 0.01 V increments,
positive and negative
Waveform
Status
Transformation
Types Inverting or non-inverting
Boot Status Hysteresis
Self-test 0.2 to 2.0 V, 0.2 V increments
Over/Under Speed 0.2 to 1.0 V, 0.2 V increments
Activity (Optical )
Edge Pulse AC Gain
Detection 1, 2, 5, 10
Error detection indicated if Minimum Input
change in rotative speed between Duty Cycle
consecutive Keyphasor pulses is 1.0 µS pulse
greater than 25%, or shaft
rotative speed is less than 1 rpm,
or greater than 120k rpm

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 11 of 31
Maximum Data Collection
Trigger Error Trigger/Event
with Sine Wave
Triggers
Input
Amplitude
Input ≤ 1kHz: < 0.5 deg,
Any variable, “or”, per channel.
1kHz – 20 kHz: < 1 deg
(amplitude, phase, nX, Direct,
Input Multiplier Bandpass, Gap, Process Variable)
/ Divider
Rpm
3 stages per input channel,
Upper and lower level, per speed
8 digits pre decimal, 12 digits post input
decimal per stage, configurable
Time
ratio or real number in software.
User-programmable, recurring,
scheduled
3
Note : Speed Input KPH Card Amplitude vs. Frequency External
Cumulative Error: Contact
Frequency dependent amplitude High or low voltage input ,
and phase errors added to fixed “normally open”, “normally
range specifications. closed” logic selectable in
Amplitude software
error vs. High Voltage
frequency 90 V to 240 V (AC or DC)
+ 1% to (-1.5) % from 0.1Hz to 4 mA Maximum current
20kHz 62 kΩ ± 2 %
Phase error vs. (High voltage input to return)
frequency
Low Voltage
(-1.5) to (-2.5) deg from 0 to 2kHz
5 V to 30 V (AC or DC)
(-2.5) to (-12) deg from 2kHz to
10kHz 15 mA Maximum current
2.15 kΩ ± 2 %
(Low voltage input to return)
Sampling
Events
∆rpm
1 rpm to 120k rpm, min 1 rpm
increments
∆Time
0.1 s to 999 hours, 0.1 s
increments.
16 ms minimum event period for
all sampling events.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 12 of 31
4
Digital Replay Note :Speed Input/KPH Card amplitude cumulative
KPH/Speed (total) error
Input AC Accuracy Speed Input/KPH signal processing is
Measurements independent from dynamic data produced by the
Speed Input/KPH cards (168906-02) delivered prior standard dynamic sampling card. Reprocessing of
to November 2006 require an update to work data from the standard sampling card is therefore
properly with the Digital Replay Card. not subject to any additional signal processing
When in replay mode, there is no alteration to errors.
dynamic sampler data. The following apply to KPH
measurements, in addition to standard operational
KPH specifications except where noted: Transducer Power Supply Card
Slot Positions
Event Rate = Shaft rpm x Events/rev: Slots 1 through 5
Event Rate Rpm Error Phase Error
1 to 6k +/- < 1 rpm +/- < 1 deg Voltage Outputs

6k to 30k +/- 4 rpm +/- < 1 deg -24Vdc (-23.35Vdc to -24.48 Vdc)

30k to 60k +/- 7 rpm +/- 1 deg


Max Current
60k to 90k +/- 20 rpm +/- 1 deg
84.5 mA ± 4.5 mA
90k to 120k +/- 40 rpm +/- 2 deg
120k to 300k N/A +/- 3 deg (typ) Short Circuit
300k to 600k N/A +/- 6 deg (typ) 55 mA ± 5mA per output, 8
outputs maximum
600k to 900k N/A +/- 8 deg (typ)
+24Vdc (+24.48Vdc to +23.34
900k to 1200k N/A +/- 9 deg (typ) Vdc)

Amplitude Current When


Sine wave input up to 8 Vpp any Shorted
full scale range. 52 mA ± 5mA per output, 4
outputs maximum
4
Raw Outputs
AC Error Current Outputs
-1.31% to 0.82% (+) Bias
DC Error 3.36 mA ± 0.3mA @ Load: 10 Ω to
± 60 mV 6.5 kΩ per output, 4 outputs max

Conditioned (-) Bias


4
Outputs 3.30 mA ± 0.36mA @ Load: 10 Ω
AC Error to 6.5 kΩ per output, 8 outputs
-1.45% to 0.79% max
DC Error
- 0.35 V to +60 mV

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 13 of 31
Status Environmental
Indication
Operating
Boot Status Temperature
OK Detection 408 DSPi and External Power
Current Limit Supply
Current Source - Bias (+/-) 0˚ C to +50˚ C (+32˚ F to +122˚ F)
Voltage Source - Bias (+/-) Note: Rated specifications at fan
inlets. Do not block fans during
Physical operation, un-obstructed airflow
Dimensions is required.
408 DSPi (L x W Storage
x H) Temperature
36.1 x 41 x 10 cm (14.25 x 16 x 3.8 -30˚ C to +80˚ C (-22˚ F to +176˚ F)
in) Relative
Power Supply (L Humidity
x W x H) 0% to 95% non-condensing
18.3 x 13.7 x 9.1 cm (7.2 x 5.4 x 3.6 Vibration
in) Operational
0.25G @ 5-100Hz
Weight Non-
408 DSPi operational
9.5 kg (21 lbs) @ 32 channels 3G @ 5-100Hz
Power Supply Shock
1.3 kg (3 lbs) 10G @ 2mS operational & non-
operational

Construction Environmental Considerations


408 DSPi The 408 DSPi is designed to meet a broad range of
Aluminum Chassis with cast use cases and environments. Significant design
aluminum front and rear measures have been implemented to provide a
panels. robust electrical and mechanical package. Shock
isolation mounts are used internally on critical
Black Powder Coating – textured
finish, indoor/outdoor use. components and careful attention focused on
reliability of the system including extensive shock,
Environmentally sealed vibration, and temperature exposure. The robust
momentary tactile switches. shipping case is designed for transportation and
Bayonet locking external power shipment in the most rigorous environments.
connector

The 408 DSPi is a measurement “instrument” and


should be treated with the appropriate
consideration. Exposure to “extreme” environments
will have constraints. Direct exposure to condensing
liquids, rain, sand, or other particulates that could
impair ventilation are however, not appropriate. In
scenarios that may exceed environmental
specifications custom solutions can be created to
meet specific needs. If you have any questions
regarding an application please contact your local
Bently Nevada representative.
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 14 of 31
Input Power
CE Mark Directives
External Power
EMC Directives 2004/108/EC – with amendments
Supply
Declaration of Conformity available online -
Input
http://www.GEmeasurement.com
90/264 Vac, 47/63 Hz auto
sensing
Harmonics
Output
EN 61000-3-2:2001
+32 Vdc ± 5% @ 10 A Max
Flicker
+5 Vdc ± 3% @ 600 mA Max
EN 61000-3-3:1995 w/A1:2001
Surge
Protection EN61000-6-2:2005 Generic Immunity - Industrial
Up to 2kV Max Electrostatic
LED Indicators Discharge
AC Power ready IEC 61000-4-2:1995
DC Output enabled Electro-
Magnetic Field
Fault Latch Detection
IEC 61000-4-3:1995
Faults
Electrical Fast
AC supply fault
Transient
Over/Under output voltage
IEC 61000-4-4: 1995
error
AC Power
Over current detection
Signal Ports
Thermal protection
Surge
(Faults are latching and require
Capability
AC power cycle to reset)
IEC 61000-4-5:1995
AC Power
Approvals
Signal Ports
System
RF Conducted
CE Mark Immunity
External Power IEC 61000-4-6:1996
Supply Only
AC Power
CSA (NRLT/C) Certification (CSA,
Signal Ports
and UL by CSA, KEMA (Europe)
and CB). Voltage Dips/
Interrupts
IEC 61000-4-11:1994
AC Power

To obtain the CE Certification, the rear panel


grounding switch was removed from the circuitry.
The switch has no impact to isolate the chassis.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 15 of 31
EN61000-6-4:2007 Generic Emissions - Industrial
Radiated
Emissions
CISPR 16
Conducted
Emissions
CISPR 16
AC Power
Telecom Ports

USA EMC
CFR 47 FCC
Radiated
Emissions
FCC 15
Conducted
Emissions
FCC 15

Low Voltage Directives


EN 60950:2001
EN 61010-1: 2001

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 16 of 31
Ordering Information 04 AC Power Supply with US
10A/250V Power Cord
For a detailed listing of country and product
05 AC Power Supply with Euro
specific approvals, refer to the Approvals Quick 10A 2 Wire Power Cord
Reference Guide (document 108M1756) located at
the following website: www.GEmeasurement.com. 06 AC Power Supply with Brazil
10A/250V Power Cord
408 DSPi G: Carry Case Option
168679-AXX-BXX-CXX-DXX-EXX-FXX-GXX-HXX-IXX-JXX 00 None
All accessories are ordered as separate line items 01 Hard Shipping Case
A: Slot # 1 Option 02 Soft Carry Case
00 Empty Slot Note: Soft carrying case holds one DSPi only. The DSPi
01 8 Ch Dynamic Sampler Card power supply or other accessories will not fit. The 408
cannot be shipped as freight in the soft case. The DSPi
02 3 Ch Speed Input (KPH) /
cannot withstand vibration or shock while in the soft case.
Trigger Card The soft case is smaller and lighter than the hard case.
03 Transducer Power Supply Card
B: Slot # 2 Option H: Metrology Certification Option
00 Empty Slot 00 None
01 8 Ch Dynamic Sampler Card 01 All Cards
02 3 Ch Speed Input (KPH) / I: Rack Mount Kit Option
Trigger Card
00 None
03 Transducer Power Supply Card
01 with 19 in Rack Mount Kit
C: Slot # 3 Option
J: Solid State Drive Option
00 Empty Slot
01 300 GB Solid State Drive
01 8 Ch Dynamic Sampler Card
02 600 GB Solid State Drive
02 3 Ch Speed Input (KPH) /
Trigger Card
What is included when ordering the 408 DSPi (168679):
03 Transducer Power Supply Card
1 Ethernet Cable – Cat5e with ferrite, 3 m (10 ft), required
D: Slot # 4 Option to meet CE certification.
00 Empty Slot Signal Input Cables are included with each Dynamic
01 8 Ch Dynamic Sampler Card Sampler - quantity 8, and Speed Input (KPH) card - quantity
6, when ordered with the 408 DSPi (168679). Additional
02 3 Ch Speed Input (KPH) /
signal input cables (172068) can be ordered separately if
Trigger Card needed.
03 Transducer Power Supply Card Laser KPH transducer input adapter cable (169714-01) and
E: Slot # 5 Option Transducer Power Supply cables and accessories are
ordered separately.
00 Empty Slot
01 Digital Replay Card w/o
ADRE Sxp Software
Analog Output Card
4080/01-AXX-BXX-CXX-DXX-EXX-FXX-GXX
02 Digital Replay Card w/ Analog
Output Card A: Version
03 Transducer Power Supply Card 01 Initial Order
F: Power Supply Option 98 Update
00 None B: Full Function Client - License Quantity (2)
01 90/264 Vac 47/63Hz (2US, 1 EU, 00 None
1 Br Power Cords Included) 01 One (1) Client License
03 AC Power Supply with US 02 Two (2) Client Licenses
10A/125V Power Cord
10 Ten (10) Client Licenses
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 17 of 31
C: Network Viewer Edition - License Quantity (2)
00 None ADRE Sxp Technical Support Plan
01 One (1) Client License 4080/20-AXX
02 Two (2) Client Licenses A: Number of Years
10 Ten (10) Client Licenses 01 One (1) Year – Single License
D: Archive Viewer Edition - License Quantity 02 Two (2) Years - Single License
00 None 03 Three (3) Years - Single License
01 One (1) Client License 04 Four (4) Years - Single License
02 Two (2) Client Licenses 05 Five (5) Years - Single License
10 Ten (10) Client Licenses
(1) (2) ADRE Quick Configuration Software
E: Full Client - Media Quantity
100M5072-01 Quick Configuration Software
(For use with ADRE Sxp. 2.8 or later.
00 None
Please contact your local sales
01 One (1) CD-ROM representative for additional ordering
02 Two (2) CD-ROMs information)
10 Ten (10) CD-ROMs
F: Network Viewer Edition - Media Quantity
(1) (2) Setting up an ADRE is now as simple as 1, 2, 3 when using
the ADRE Quick Configuration software.
00 None
01 One (1) CD-ROM
1. Arrange the cards.
02 Two (2) CD-ROMs
10 Ten (10) CD-ROMs

(1)
G: Archive Viewer Edition - Media Quantity
00 None
01 One (1) CD-ROM
02 Two (2) CD-ROMs
2. Sketch the machine.
10 Ten (10) CD-ROMs

(1) Media quantity must be either (1) or equal to


license quantity
(2) Includes ADRE* Quick Configuration Software
Media P/N 100M5072-01

3. Plug it in.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 18 of 31
The ADRE Quick Configuration software allows even the
novice user to create an Sxp-ready database to configure Digital Replay Card
ADRE and start receiving data within minutes. Bently best
168907-AXX-BXX-CXX
practices are integrated into the drag and drop menu to
automatically create data collection parameters and a A: Approvals
suite of plots to ensure the full power and productivity of
the ADRE system is realized.
0 2 option only (CE approved)
B: Output Option
The newest to the most experienced ADRE user can take 00 No output
advantage of the ease, speed, and expertise of the ADRE 01 With analog output
Quick Configuration software so that more time is spent
enhancing productivity utilizing the data, and less time
C: Cables (only applicable if B option = 0 1)
worrying about manually configuring the system. 00 Not Included
01 One 8 Channel Cable
02 Two 8 Channel Cables
Bently BALANCE* Software 03 Three 8 Channel Cables
3030/01-AXX Multi-Plane Balancing Software 04 Four 8 Channel Cables
(For use with ADRE Sxp. Requires
Bently Balance* Version 3.2 SP1
or later. Please contact your Note: Speed Input/KPH cards (168906–
local sales representative for 02) delivered prior to November 2006
additional ordering information) require an update to work properly
with the Digital Replay Card.
408 DSPi Accessories
(Accessories are ordered as separate line items.) Transducer Power Supply Card
168908-AXX-BXX
8-Channel Dynamic Sampler Card
168905-AXX A: Approvals
0 2 option only (CE approved)
A: Approvals
B: Output Accessory Option
0 2 option only (CE approved)
00 None
3-Channel Speed Input/KPH Trigger Card
Impact Hammer Kit
168906-AXX
Impact_Hammer_Kit - AXX-BXX-CXX-DXX-EXX-FXX
A: Approvals
Note: Transducer Power Supply Card recommended/required
0 2 option only (CE approved)

Requires appropriate adapter cable to A: 500lbf pk, 10mV/lbf, 0.3lbm (285570-01)


connect optical transducer inputs. 00 None
Note: Speed Input/KPH cards 01 Hammer Included
(168906–02) delivered prior to B: 1000lbf pk, 5mV/lbf, 0.3lbm (285570-02)
November 2006 require an update to 00 None
work properly with the Digital Replay
Card. 01 Hammer Included
C: 00 None
D: Std Accelerometer Set (200350, 100mV/g ±50g )
00 None
04 Set of 4
08 Set of 8
E: 00 None
F: 00 None

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 19 of 31
What is included when ordering the Impact Hammer Kit: additional cable length for a total of ~ 3
The Impact Hammer Kit can be configured with m (10 ft). Convenient for rack mount
various types of impact hammers and applications.
accelerometers. The kit includes a case suitable to fit
all components. 169234 - 01 408 DSPi 19 in Rack Mount Kit
Each hammer includes an assortment of tips and the
necessary cable for connection to the 408DSPi.
123135 Velomitor Power Module Kit – Provides
Accelerometers can be ordered in sets of 4 or 8, and
power and connects up to four
each one will include the necessary cable for
Velomitor transducers.
connection to the 408 DSPi. See Figure 4.
Each component of the Impact Hammer Kit can also
be ordered individually if needed, i.e. cables, etc. 169714 - 01 Keyphasor input adapter cable (0.5m).
Please refer to the datasheet for the Impact Hammer Connects laser transducer kits to KPH
Kit for details. card 168906 – 02 (or /01). See Figure 3.
Note: The impact hammers and accels require a
constant current power source. If the end user does 166812 - 01 Laser transducer kit with 2m cable.
not already have a method to power these devices, a Includes transducer and extension
Transducer Power Supply Card (168908-AA-BB) will cable. Requires adapter cable
be required. 169714 - 01 to connect to KPH card
Additional Accessories (Accessories are ordered 168906 – 02 (or /01). See Figure 3.
as separate line items)
166813 - 01 Laser transducer kit with 5m cable
172068 Signal Input Cable - SMA to BNC, 3 m (10 Includes transducer and extension
ft) required for 168905 – 02 (or /01), and cable. Requires adapter cable
168906 – 02 (or /01). 169714 - 01 to connect to KPH card
168906 - 02 (or /01). See Figure 3.
173887 SMA Push-On Adapter, for SMA to BNC
cable 172068. Allows SMA cable 284814-020 Laser transducer extension cable 20m
connector to be pushed onto signal
input connector for convenience.
02290050 Reflective tape roll
286241 BNC male to SMA female Adapter
174968 Fan vent cover update/replacement kit
174466 Ethernet Cable – Cat5e with ferrite, 3 m
(10 ft). Required to meet CE certification.
(quantity 1 included with 408DSPi) 176472 European AC Power Cord
250V 2.5m
169633 408 DSPi Hard Shipping Case
178775 - 01 408DSPi Transducer Power Supply Card
Standard Field Wiring Harness. See
288390 408 DSPi Soft Carrying Case Figure 5 and Figure 6.

169337 408 DSPi External Power Supply 178762 - 01 408DSPi Transducer Power Supply Card
Modular Field Wiring Harness (requires
90/264 Vac 47/63 Hz 178763-01) See Figure 5 and Figure 7.

178763 - 01 408DSPi Transducer Power Supply Card


169347 - 01 External Power Supply to 408DSPi Modular Wiring Adapter. See Figure 5.
Extension Cable, 1.8 m (6 ft). For use with
169337. Using this cable provides
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 20 of 31
178897 - 01 408DSPi Transducer Power Supply Card Answer: 178762-01 and 178897-01 (2 each would
Field Wiring Terminal Kit. See Figure 5. be required if channel count was greater than 4)
and 178763-01; Transducer connection PWR, COM
and SIG on 178897-01; connect 178897-01 to
177067 - 01 ADRE 408 Protective Cover Assembly
178762-01; connect individual channel on 178762-
01 to individual channels on 178763-01; individual
287743 ADRE 408 Analog Output to 8X BNC channels can use either the 1st 4 connector
Cable positions with the Voltage Source switch in the
289043 - 01 ADRE 408 Analog Output Rebuild Kit (neg-) position or use the 2nd 4 connector
(only for existing Replay Cards) positions. Daisy chaining is possible up to 3 per
channel.
6. What do I need to order if I want to power 9 to 24
Transducer Power Supply cable Frequently Ask Questions:
negative bias 3-wire transducers (Accelerometers,
1. What do I need to order if I want to power 1 to 4 Velomitors, or Proximitor Probe).
positive biased Accelerometers/Velomitor (2-wire)
Answer: 178762-01 and 178897-01 (each cable
constant current transducers.
can take 4 channels so order accordingly),
Answer: 178775-01 and 178897-01, Transducer 178763-01 use all 8 connector positions and
connection A to COM and B to SIG on 178897-01; connect in the same manner in Question #5. You
connect 178897-01 to 178775-01; connect can daisy chain up to 3 channels per 178763-01
178775-01 to input channels 5 through 8 on channel.
168908 which is provided with the Transducer
7. What do I need to order if I want to power 1 to 4
Power Supply; set the Constant Current switch in
positive bias 3-wire transducers (Accelerometers,
the (pos +) position.
Velomitors, or Proximitor Probe).
2. What do I need to order if I want to power 5 to 8
Answer: 178762-01, 178763-01, 178897-01;
positive biased Accelerometers/Velomitor (2-wire)
Transducer connection PWR, COM and SIG on
constant current transducers.
178897-01; connect 178897-01 to 178762-01;
Answer: This would require an additional connect individual channel on 178762-01 to
Transducer Power Supply 168908-02 and 2 set of individual channels on 178763-01 only using
178775-01 and 178897-01, Transducer connection channel inputs 1-4; Voltage Source switch in the
will be the same as Question #1. (pos +) position.
3. What do I need to order if I want to power 1 to 8 8. What do I need to order if I want to power 5 to 12
negative biased Accelerometers/Velomitor (2- positive bias 3-wire transducers (Accelerometers,
wire) constant current transducers. Velomitors, or Proximitor Probe).
Answer: 178775-01 and 178897-01 (both are 4 Answer: (2 or 3) 178762-01, (2 or 3) 178897-01 01
channel connectors so a set of 2 would be (each cable can take 4 channels so order
required for 5 to 8), Transducer connection B to accordingly), 178763-01, use only the first 4
COM and A to SIG on 178897-01; connect 178897- connector positions on 178763-01 and connect in
01 to 178775-01; connect 178775-01 to 168908 the same manner in Question #7. You can daisy
which is provided with the Transducer Power chain up to 3 channels per 178763-01 input.
Supply; set the Constant Current switch in the
9. What do I need to order if I want to power 13 to
(neg -) position.
24 positive bias 3-wire transducers
4. What do I need to order if I want to power more (Accelerometers, Velomitors, or Proximitor Probe).
than 9 to 16 negative biased
Answer: This would require an additional
Accelerometers/Velomitor (2-wire) constant
Transducer Power Supply 168908-02 and (4 to 6)
current transducers.
178762-01, (4 to 6) 178897-01 01 (each cable can
Answer: This would require an additional take 4 channels so order accordingly, 178763-01,
Transducer Power Supply 168908-02 and up to 4 use only the first 4 connector positions on
set of 178775-01 and 178897-01 (both connectors 178763-01 and connect in the same manner in
are capable of having 4 channels), Transducer Question #8. You can daisy chain up to 3
connection will be the same as Question #3. channels per 178763-01 input.
5. What do I need to order if I want to power 1 to 8
negative bias 3-wire transducers (Accelerometers,
Velomitors, or Proximitor Probe).
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 21 of 31
Minimum Computer Requirements needs can be very different and therefore we do
ADRE Sxp software will run on most computer not recommend generic solutions. We can provide
systems, desktop or notebook, provided that the peripherals such as printers, external hard drives,
systems meet minimum specifications. This monitors, or other devices that best meet your
datasheet provides recommended computer needs. Please provide your sales representative
requirements; inadequate specification will impact with specific requirements.
software operation and system performance and
the ability for the system to achieve maximum Operating System Requirements & Support
specifications. You must follow the “recommended ADRE Sxp software is designed to run and fully
computer specifications” to realize the full system tested on Microsoft® Windows 7 and Windows 8.
performance. ADRE Sxp software can be installed on Microsoft
Windows Vista. ADRE Sxp software cannot be
Recommended Computer Specifications installed on earlier versions of Microsoft Windows
operating systems such as Windows 95/98/NT/XP.
 2.4 Ghz or faster, Xeon
 1.8Ghz or faster, Dual Core (notebooks) Networking Requirements
 2 GB RAM ADRE Sxp software requires an available Ethernet
 160-250 GB HDD port with TCP/IP protocol support to communicate
 DVD±RW with the 408 DSPi. A 1000 MB (GB) Ethernet port is
required for the 408 DSPi to meet full performance
 1000/100 MB Ethernet specifications. Under typical conditions with only
 SXGA 128MB VRAM one or two clients accessing the 408 DSPi, 100MB
Ethernet will provide excellent performance.
ADRE Sxp Notebook Computer Bandwidth sharing on any network, depending on
traffic, is always a consideration and will affect
169849 High Performance Notebook Computer network performance. Ensure that all networking
This computer does not have an external hardware is installed and configured according to
parallel port. You can also use this computer your network administrator’s specifications.
with ADRE for Windows software but it is not
compatible with the 208DAIU. Database Access and Storage
 2.4 Ghz i7 Processor The 408 DSPi can store 292-600 GB of data
 8 GB RAM internally. For applications that may need
significantly more storage capacity, an external
 500 GB (or higher) HDD rack mounted drive array can also be added.
 DVD±RW Permanent installations, test stands, or very long
 1000/100 MB Ethernet term storage of raw streamed data can easily be
supported with an external drive array.
 802.11 a/b/g draft-n WLAN
w/Bluetooth®
 USB 2.0 (or higher) You can use the ADRE Sxp software to view all
data on the 408 DSPi, thereby minimizing the need
 15” HD + 1920x1080, 512MB VRAM to move large datasets over the network. Users
 720p HD webcam can move entire databases or just the portion they
 Windows® 8 Profession 64-bit OS need to a client computer. Because moving large
databases over a network can consume
 Notebook Carry Case significant bandwidth and affect network
 SanDisk Cruzer 32 GB USB 2.0 Flash performance we recommend that you use a
Drive dedicated or high bandwidth network or a local
(direct) connection between the 408 DSPi and the
ADRE Sxp client computer.
Computer Peripherals
Users should evaluate the selection of additional
external peripherals on a case-by-case basis. User

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 22 of 31
Archive Viewer Edition – The Archive Viewer
Data/Database Export software is intended for situations when a user
All versions of ADRE Sxp software provide the ability requires support from other personnel, typically
to export all data to a generic delimited spreadsheet from a corporate support team or consultant. In
format. Users can select specific data types, static such cases, support personnel will not actually be
(by variable type), and/or dynamic waveforms. configuring or collecting live data from the 408.
Exported data can then be imported into many 3rd Once a user has archived and moved data from
party applications for different types of analysis the 408, the Archive Viewer provides all viewing
and/or presentation needs. features and data manipulation capability. The
Archive Viewer allows users to open databases
only after they have been archived and moved to
another computer or placed on storage media.
Data/Database Import
The Archive Viewer is not able to connect to a 408
The latest versions (3.1 greater) of the ADRE Sxp at all.
software provide the ability to import vector and
waveform data from a generic delimited
spreadsheet format. Users can select a direct static
type, and asynchronous waveforms. Imported data
can be presented in the ADRE Sxp software for
different types of analysis and/or presentation
needs.

ADRE for Windows


ADRE Sxp software provides complete support for
existing ADRE for Windows databases. This allows
users to continue using existing ADRE for Windows
systems as needed while sharing data with those
running ADRE Sxp software. Although ADRE Sxp
does not communicate directly with the 208 DAIU,
ADRE for Windows software can run on the same
computer as ADRE Sxp. Contact your local
technical support representative for details
specific to your needs.

Network and Archive Viewer Edition Software


There are two "Viewer Edition" options for ADRE
Sxp that are specifically designed to meet use
case scenarios that do not require active control
or configuration of a 408 DSPi. All versions of ADRE
Sxp can read all ADRE for Windows databases.

Network Viewer Edition - The Network Viewer


allows a user to "connect to a 408" and view live
data or any archived data on the 408. Users need
this if they wish to view live data, participate in a
live test, etc. The network viewer can also display
all archived data, either locally, or on the 408. This
option is intended for applications that require
remote participation in data collection or viewing
of live data, as well as local viewing of archive
data.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 23 of 31
Full Network Archive Display Plot / Formats
ADRE Sxp Client Versions Function Viewer Viewer
The following plots can be selected from stored
data. Users can configure the display to show only
the applicable plots for any given application
Functionality
package.
View historical data on local
computer     Current Values
View historical data stored on
    Tabular List
network server/drive
 Orbit / Timebase (w/ superposition of
Import and view ADRE for
Windows data    overlay)
Configure, save, and view plots  Orbit (w/ superposition of overlay)
and plot sessions   
 Timebase (w/ superposition of overlay)
Export Static and Dynamic Data     Continuous Raw Timebase (w/multi
   decimation)
Build 408 Configurations
    Bode (w/ Forward & Reverse Vector
View Configurations transforms, coming soon)
Connect to 408    Polar (w/ Forward & Reverse Vector
  transforms)
Upload Configurations to 408
 Shaft Centerline (Average and Instantaneous
View Real-time Data on 408  
position & Orbit Overlay)
Download data from 408 to
local computer    X vs. Y
   Trend / Multivariable Trend
View Network Settings on 408
 Spectrum / Full Spectrum
Quick Configuration Software  
 Waterfall / Full Waterfall (w/ Campbell
408DSPi Control & Operation  format)
  Cascade / Full Cascade (w/ Campbell
Enter & Exit Store Enable
format)
Manual Sample 
 Structural Analysis (Timebase
Control Triggering  w/Rectangular and Exponential Windows)
Modify and Save Configuration  Structural Analysis Results (w/Transfer
Changes  Function, Coherence, Auto/Cross Spectrum)
On-the-fly Configuration  System Event List
Changes 
Set Active
Database/Configuration  Multi-Plane Balancing Software
 Bently BALANCE* software (3030/01) is designed
Modify System Properties
specifically to integrate with your ADRE system.
Update/Service 408  ADRE Sxp databases can be imported directly into
 Bently BALANCE 3.2 SP1 (and later) providing
408 Diagnostics analysis and a comprehensive solution for your
Configure Network Settings  most challenging balancing needs. You can also
import/export data directly from/to spreadsheets
into Bently BALANCE, adding great flexibility to
your balancing program. Bently BALANCE includes
powerful optimization tools, multiple sets of
influence vectors, and multiple “what-if” solutions,
all while viewing graphical results on plots and
weight maps. Bently BALANCE is a powerful part of
your total diagnostic and maintenance program.
Contact your local sales representative for more
details.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 24 of 31
Software Licensing
ADRE Sxp software is available as a single
“computer” license. A separate license is required
for each installation of this product on a different
computer. Contact your local sales or service
representative to purchase or discuss “site” or
“enterprise” licensing requirements.

Software Technical Support Agreement


The Software Technical Support Agreement (TSA)
allows you to contact our Product Service
department for assistance at any time during the
selected period of coverage. The support
agreement period begins with your initial request
for assistance, first software update, or three
months after your order, whichever comes first. In
addition to e-mail, fax, and telephone support, the
Support Agreement provides free software
updates as well as updates via the Internet. Your
Technical Support Agreement ensures that you
have access to the most current version of
software with all the latest enhancements.
Technical support plans are available for single
and enterprise wide installation of our software
products. Contact your local sales representative
for details specific to your needs.

Registration for ADRE Sxp Technical Support


Registration of the ADRE Sxp software product is
the only way to activate your Technical Support
Agreement. Please contact your local Technical
Support representative or visit us online for details
specific to product registration.

Training Programs
Training is essential to ensure users are able to
realize full value from their tools in the most
efficient manner. Our technical training group can
provide training to meet your needs. Training
specific to ADRE Sxp and the 408 DSPi can be
provided at your facility or at one of many Training
Centers located around the world. Contact your
local sales representative for details specific to
your needs.

Documentation (can be ordered separately)


176559-01 ADRE Quick Start Guide
172179-01 ADRE Sxp / 408 DSPi Datasheet

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 25 of 31
Graphs and Figures

Figure 1: ADRE Sxp/408 DSPi Front View

Figure 2: ADRE Sxp/408 DSPi Rear View

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 26 of 31
Figure 3: 408 DSPi with Optical KPH and Laser Tachometer speed input transducers.

Figure 4: 408 DSPi with Impact Hammer and Accelerometer.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 27 of 31
1. Standard terminal plug (included with 168908)
2. Modular wiring adapter (P/N 178763-01). Required for 178762-01.
3. SMA push-on quick-connect adapter (P/N 173887).
4. 4-connection standard wiring harness for 2- or 3-wire transducers (P/N 178775-01). See Figure 6 for detail.
5. 4-connection modular wiring harness for 2- or 3-wire transducers (P/N 178762-01). See Figure 7 for detail. Note:
Modular wiring harness can be stacked only with 3-wire voltage powered connections (will not work with constant
current transducers).
6. Field wiring terminal kit (one 12-position terminal and jumpers P/N 178897-01).
7. Field wiring for 2-wire constant current transducers with negative bias.
8. Field wiring for 2-wire constant current transducers with positive bias.
9. Field wiring for 3-wire positive or negative voltage powered transducers.
Figure 5: Field Wiring Cables for Transducer Power and Signal Input
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 28 of 31
1

1. Reverse side of connector.


2. Detail of wiring legend label.
Figure 6: Detail of Standard Wiring Harness 178775-01

1. Reverse side of connector.


2. Detail of wiring legend label.
Figure 7: Detail of Modular Wiring Harness 178762-01
Specifications and Ordering Information
Part Number 172179-01
Rev. T (09/15)

Page 29 of 31
1. ADRE 408 Replay Module with Analog Outputs
2. ADRE 408 Analog Output to 8X BNC Cable
Figure 8: 408 DSPi with Replay Module and Analog Output to 8X BNC Cable.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 30 of 31
*Denotes trademarks of Bently Nevada, Inc.,
a wholly-owned subsidiary of General Electric Company.
© 2006 - 2015 Bently Nevada, Inc. All rights reserved.

Printed in USA. Uncontrolled when transmitted electronically.

1631 Bently Parkway South, Minden, Nevada USA 89423


Phone: 775.782.3611 Fax: 775.215.2873
www.GEmeasurement.com

Microsoft, Windows 8, Windows 7, Windows Vista, Windows XP


are registered trademarks of Microsoft Corporation in the United States and/or other countries.
Bluetooth is a trademark of Bluetooth SIG, Inc.

Specifications and Ordering Information


Part Number 172179-01
Rev. T (09/15)

Page 31 of 31

You might also like