Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Inner-Board Connector: Epld External Interface

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Board function-Main Processing Unit (MPU)

MPU/SRU
 Routing processing board includes CPU
Adapter Route Process
Unit module, the external interface module,
Power
module stratum-3 clock, etc.
Power
module
 the Routing processing board provides the
LSW following functions:
module
CPU  Route calculation;
module
 Outband communication between boards;
Monitorin

External Interface
g module  Device management and maintenance;

FPGA
Storage
module  Data configuration;
Clock
Driver  provide two-channel 2.048-MHz

EPLD

Backplane connector
Inner-Board connector
stratum- synchronous clock signals for the
3 clock
Switch downstream devices, or receive 2.048-MHz
Module
or 2.048-Mbit/s external reference clock
signals.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page25
SRU of the CX600-X8
An SRU consists
An SRU consists ofof the
the CPU,
CPU, storage
storage
module, interface module, clock
module, interface module, clock module,
module,
USB communication
communication module,
module, monitoring
monitoring module,
module,
port and
and power
power module.
module.
The SRUs of
The SRUs of the
the CX600-X8
CX600-X8 areare integrated
integrated
with
with SFUs.
SFUs.
Slot for a
CF card of
up to 1GB Highlights of the
Highlights of the SRU
SRU
Two
Two USBUSB ports:
ports: supporting
supporting version
version
downloading
downloading through
through USBUSB devices
devices and
and
power
power supply
supply forfor USB
USB devices
devices
1588 v2 Inside
CF card with mass storage
CF card with mass storage capacity capacity
(up to 1 GB)
(up to 1 GB)
RJ-45 connector, Compatible
Compatible with with the
the design
design of
of disks
disks
providing clock RJ-45/SMB connector: processing
RJ-45/SMB connector: processing
information and BITS Stratum-3
clock
Stratum-3 clock
clock and
and 1588
1588 clock;
clock;
supporting input and output
supporting input and output of of
2MHz/2Mbps/1PPS clock
2MHz/2Mbps/1PPS clock signals signals
SMB connector,
High performance multi-core
High performance multi-core CPU
CPU
providing clock The bandwidth of
The bandwidth of the
the control
control bus
bus
information and BITS between
clock
between thethe SRU
SRU and
and the
the LPU
LPU is
is
increased
increased to to 11 Gbit/s.
Gbit/s.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page26
SRU of the CX600-X16
An MPU consists
An MPU consists of
of the
the CPU,
CPU, storage
storage
USB port module,
module, interface
interface module,
module, clock
clock module,
module,
communication
communication module,
module, monitoring
monitoring module,
module,
and power module.
and power module.
Slot for a CF
Highlights of the
Highlights of the MPU
MPU
card of up to
Two
Two USB USB ports:
ports: supporting
supporting version
version
1GB
downloading through USB devices
downloading through USB devices and and
power supply for USB
power supply for USB devices devices
1588v2 Inside CF
CF cardcard with
with mass
mass storage
storage capacity
capacity (up(up
to
to 11 GB)
GB)
Compatible
Compatible with with the
the design
design of
of disks
disks
1G/2.5G SFP connector, RJ-45/SMB connector: processing
RJ-45/SMB connector: processing
supporting the architecture Stratum-3
Stratum-3 clock
clock and
and 1588
1588 clock;
clock; supporting
supporting
of multi-chassis cascading input
input and
and output
output ofof 2MHz/2Mbps/1PPS
2MHz/2Mbps/1PPS
clock signals
clock signals
High performance multi-core
High performance multi-core CPU
CPU
RJ-45 connector,
The bandwidth of the control
The bandwidth of the control bus bus
providing clock
information and BITS
between
between the the MPU
MPU andand the
the LPU
LPU isis
clock increased to 1 Gbit/s.
increased to 1 Gbit/s.
Providing
Providing two two 1G
1G oror 2.5G
2.5G SFP
SFP interfaces
interfaces
SMB connector, for
for future
future expansion
expansion intointo clusters
clusters
providing clock The architecture is
The architecture is designed
designed toto be
be
information and BITS compatible
compatible withwith the
the SFU
SFU function
function onon future
future
clock MPUs.
MPUs.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page27
SFU Boards
 Switching Board comprises of
CPU module, switching module
and CMU.

 Mainly responsible for switching


data between LPUs.

 -X16 has four SFUs that work


in 3+1 load balancing mode.

 X8 support 2+1 load balancing


mode

 Indicators on panel include


ACT indicator, RUN indicator
and OFL indicator.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page28
SFUs of the CX600-X8
Channels: Each SFU provides 12 Redundancy: Three SFUs work in load
pairs of high-speed SerDes links for balancing mode. When one SFU fails,
each LPU. The rate of each pair of SRU˙
˙MPUˇ
ˇSFU
the traffic is switched to the other SFUs
SerDes links is 3.125 Gbit/s (LPU). automatically.
Control plane
SRU SRU

LPU LPU

Interface Interface

SFU

Forwarding plane

 Architecture: 2+1
 Architecture: 2+1 backup
backup of of SFUs.
SFUs. Two
Two SFUs
SFUs are
are integrated
integrated onon the
the SRU.
SRU.
 Capacity: 480
 Capacity: 480 Gbit/s
Gbit/s for
for each
each SFU.
SFU. The
The capacity
capacity of
of the
the entire
entire system
system is
is 1.44
1.44 Tbit/s.
Tbit/s.
 Features: Large
 Features: Large capacity,
capacity, congestion-free,
congestion-free, high
high reliability,
reliability, and
and supporting
supporting switching
switching capacity
capacity of
of
40G/slot.
40G/slot.
Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page29
SFUs of the CX600-X16
Channels: Each SFU provides 8 Redundancy: Four SFUs work in
pairs of high-speed SerDes links for load balancing mode. When one
each LPU. The rate of each pair of SFU fails, the traffic is switched to
SerDes links is 3.125 Gbit/s (LPU). the other SFUs automatically.

LPU LPU

Interface
Interface

 Architecture: 3+1
 Architecture: 3+1 backup
backup of
of SFUs.
SFUs.
 Capacity: 640
 Capacity: 640 Gbit/s
Gbit/s for
for each
each SFU.
SFU. The
The capacity
capacity of
of the
the entire
entire system
system is
is 2.56
2.56 Tbit/s.
Tbit/s.
 Features: Large
 Features: Large capacity,
capacity, congestion-free,
congestion-free, high
high reliability,
reliability, and
and supporting
supporting switching
switching capacity
capacity of
of 40G/slot.
40G/slot.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page30
CMU of the CX600 New System (optional)
 Extensive environment
 Extensive environment monitoring
monitoring functions
functions
Indicator
Alarm detection of
Alarm detection of the
the smoke
smoke sensor
sensor :Supports
:Supports the the connection
connection to to the
the
smoke
smoke sensor
sensor through
through the the panel
panel toto detect
detect the
the alarm
alarm signals
signals from
from the
the
chassis
chassis oror equipment
equipment room.room.
Detection
Detection of of the
the ambient
ambient temperature
temperature :Supports
:Supports the the connection
connection to to the
the
temperature sensor through the panel to detect the
temperature sensor through the panel to detect the temperature of the temperature of the
chassis
chassis oror equipment
equipment room.room.
Access control management
Access control management :Detects :Detects whether
whether access
access control
control is is
RJ-45 enabled through magnetic inspection and reports the
enabled through magnetic inspection and reports the inspection signal to inspection signal to
connector the
the device.
device. The
The remote
remote unlocking
unlocking function
function isis reserved.
reserved. You You can
can instruct
instruct the the
CMU to enable or disable access control through
CMU to enable or disable access control through the remote control the remote control
function.
function.
Device alarm output
Device alarm output :The :The CMUCMU provides
provides two-level
two-level alarm
alarm output
output signals.
signals.
Main contact point inspection :The CMU can
Main contact point inspection :The CMU can provide six main contact provide six main contact
points
points to
to detect
detect signal
signal input
input and and monitor
monitor whether
whether the the devices
devices outside
outside the the
chassis work normally.
chassis work normally.
One
One 232 232 and
and 485485 serial
serial interface
interface :Provides
:Provides an an RS-232
RS-232 serial
serial interface,
interface,
which is connected to the panel. You can use it
which is connected to the panel. You can use it to query or locateto query or locate
information
information about
about thethe CMU.
CMU. In In addition,
addition, thethe CMU
CMU provides
provides anan R-485
R-485 serial
serial
Panel port,
port, which
which isis connected
connected to to the
the panel.
panel. You
You cancan connect
connect anan device
device to to this
this
connector interface.
interface. The
The interface
interface supports
supports full-duplex
full-duplex mode.
mode.
Perform the system
Perform the system environment
environment monitoring
monitoring and
and access
access control
control
functions
functions
 Not require
 Not require additional
additional devices,
devices, saving
saving customers’
customers’ investment.
investment.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page31
Differences Between the Hardware of the CX600-X8
and CX600-X16
Item -X8/X16 Remarks

Backplane Different and cannot be shared Different in size

The hardware of the SFUs is the


SFU Different and cannot be shared same. The connector between the
SFU and backplane is different.
SRU for CX600-X8; MPU for CX600-
SRU/MPU Different and cannot be shared
X16

LPU Same and can be shared ˉ

Fan Same and can be shared ˉ

Fan filtering
Same and can be shared ˉ
unit
Power
Same and can be shared ˉ
module

CMU Same and can be shared ˉ

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page32
New Boards and Cards of V6R1-
LPUF40 and PIC

LPUF Mother Card

NE 40G
platform
P40 half-height
subcard v2 In side
1588
2*10GE 20*GE

NE 20G
platform LPUF21˖2*10GEˇ20*GE
P20 full-height subcard

NE 10G platform
P10㧦8*GE with1588v2
P10 half-height subcard

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page33
New Boards and Cards of V6R1- LPUF40
 Main function:
 Classify, search and forward data at a wire
speed of 40G; traffic management, process link
protocol;
searchi
ng ,forw  netstream supported by service boardOAM;
SI
module arding
module From PIC  Highlights of LPUF40㧦
 Consist of CPU module, switching interface
TO backpland TM
module
module, TM module, forwarding module, OAM

OAM&
and netstream module etc;
From PIC
CPU Netstre
am  Support flexible subcard㧘each LPUN can be
module
module
inserted with 2 subcard;
 Support CX600-X8 and CX600-X16 hardware
platform.
 Support restricted use on CX600-X3 platform.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page34
New Boards and Cards of V6R1- LPUF40
(Cont.)
Item Specifications
Dimensions (width
41mm×520mm×400mm
x depth x height)
Power consumption
About 280W
(Typical value)
Heat dissipation 908 BTU/hour
Board weight 6.6kg
type PowerPC
CPU
Frequency 1.3GHz
NP bandwidth 40Gbit/s
SRAM 288MB
Flash 32MB
Memory SDRAM 1GB
RLDRAM 6.912Gb
EEPROM 64KB

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page35
New Boards and Cards of V6R1- LPUF40 PIC
 GE optical module, providing features of GE optical interfaces.
 FE optical module, providing features of FE optical interfaces.
 Electrical interface SFP module, providing features of the
10M/100M/1000M adaptive electrical interfaces.
 Intermixing of the preceding modules.
20-port 100/1000Base-X SFP flexible plug-in card  2 types of PIC code, have the same appearance, the difference is
20-port 100/1000Base-X SFP flexible plug-in card A that the 20-port 100/1000Base-X-SFP flexible card A supports
IEEE1588v2.

 10GE optical interface XFP module;

 Support LAN/WAN mode.

2-port 10GBase LAN/WAN-XFP flexible plug-in card

 Optical interface XFP module, providing features of the


10GE adaptive;
 Support LAN/WAN mode.
 Support IEEE1588v2.
2-port 10GBase LAN/WAN-XFP FPIC flexible plug-in card A

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page36
New Boards and Cards of V6R1- LPUF21/10 PIC
 GE optical module, providing features of GE
optical interfaces

 GE optical module, providing features of GE


optical interfaces

 Electrical interface SFP module, providing


features of the 10M/100M/1000M adaptive
electrical interfaces
LPUF21: 2*10GE+20*GE  Intermixing of the preceding modules

 GE optical module, providing features of GE optical


interfaces.
 FE optical module, providing features of FE optical
interfaces.
 Electrical interface SFP module, providing features
of the 10M/100M/1000M adaptive electrical
interfaces.

LPUF10: 8*GE  Intermixing of the preceding modules.

Copyright © 2010 Huawei Technologies Co., Ltd. All rights reserved. Page37