Littelfuse Hall Effect Sensors 55140 Datasheet PDF
Littelfuse Hall Effect Sensors 55140 Datasheet PDF
Littelfuse Hall Effect Sensors 55140 Datasheet PDF
Description
The 55140 is a small flange mounting hall effect sensor occupying only 3.22cm²
(0.500”² ) board space with a choice of digital, or programmable analogue
outputs. It is available as three-wire (voltage output) or two-wire (current output)
versions. It’s case design enables screw or adhesive mounting and capable of
switching up to 28Vdc and 20mA. It comes with a range of sensitivity, cable
length and connector options.
Features
• Magnetically operated position • Vibration 50g max. @ 50-2,000Hz
sensor • Shock 150g max. @ 11ms ½ Sine
• Digital,latching or programmable • EMC to DIN 40839 (Consult
analog types available Littelfuse)
Block Diagram • Medium, high or programmable • Reverse/Over voltage protection
sensitivities • Built in temperature compensation
Two-wire Version • Three-wire (voltage output) or two- • Open Drain Output
VDD wire (current output) versions
Pin 1
(Red) Hall Current
Switch Comparator
Cn Plate Source
Benefits
GND Clock
Pin 2 • High switching speed up to 10kHz • Unaffected by harsh environment
(Black) • Long life; up to 20 billion operations • Customer selection of cable length
Notes: • Operates in static or dynamic and connector type
1. Add capacitor Cn as shown, close for the sensors for transient suppression if required. magnetic field
2. Add pull-up resistor Rpu as shown for sinking output. The Rpu value should be calculated
using your supply voltage while keeping the ON state current at a level below the
maximum. Rpu = VDD/Io; Applications
Rpu = 12Vdc/10mA = 1.2
• Position and limit sensing • Flow metering
• RPM measurement • Angle sensing
Three-wire Version • Commutation of brushless • Magnetic encoders
VDD
VDD DC motors
Pin 1
(Red) Hall Rpu
Switch Comparator Output
Cn Plate
Dimensions
Dimensions in mm (inch)
Two-wire version illustrated.
23.00
(.906) 300
6.00
(.236) Encapsulant excluded (11.81)
6.35 NOM.
(.250)
9.50
7.50 (.374)
(.295) 11.00
14.00 (.433)
(.551)
3.00 14.00
(.118) 3.20x3.81 TYP.
Slot (.12x.150) (.551)
Centre of Sensitivity
General Tol.: ±(.005) 0.13
Electrical Ratings
Output Current
mA - max. 20 N/A -1.0 to +1.0
(continuously on)
Current Consumption Low mA - min. 1.6 - 5.2 5.0 - 6.9 2.0 - 10.0
Over Temperature Range High mA - max. 1.6 - 5.2 12.0 - 17.0 2.0 - 10.0
Notes:
1. As long as Tj (Junction Temperature) is not exceeded. It is recommended to operate within the normal Operate Supply Voltage of +24Vdc maximum.
Operating beyond Absolute Ratings may cause permanent damage to the Hall IC.
2. Preprogrammed by Littelfuse or Customer pending agreement.
3. For custom modifications to the wire length or size, or adding a special connector, please contact Littelfuse.
Hall Options
Select Option Hall Type Sensitivity Gauss Activate - D
(typ.) mm (inch)
2M 2 Wire Switch 120 13.5 (.531)
2H 2 Wire Switch 57 18.5 (.728)
3M 3 Wire Switch 130 12.5 (.492)
3H 3 Wire Switch 59 18.0 (709)
AP Analog Programmable Consult Littelfuse
D Termination Specification
N S
Termination Options
Select Description
Option (Two-wire versions illustrated)
Series
Hall Option
2M, 2H, 3M, 3H, or AP
Cable Length
02
Termination
A, E, or F
Packaging
Packaging Option Packaging Specification Quantity Quantity & Packaging Code Taping Width