Control Unit Omega 804: User Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

CONTROL UNIT OMEGA 804

User manual
User manual OMEGA 804 Series

INDEX
1. DESCRIPTION AND MAIN FEATURES ................................................................... 3
2. DISPLAY AND CONTROL BUTTONS ..................................................................... 3
3. INSTALLATION AND CONNECTIONS .................................................................... 4
4. MENU STRUCTURE ................................................................................................. 5
5. HOW TO CHECK OR MODIFY PARAMETERS....................................................... 5
6. INITIAL CONFIGURATION ...................................................................................... 6
7. TYPES OF CONFIGURATION DEPENDING ON THE APPLICATION ................... 6
7.1. SYSTEM USED AS A ROPE TENSION MONITOR (WRT)...........................................................7
7.2. SYSTEM USED AS A LOAD WEIGHING DEVICE (LWD) ............................................................8
8. ADDITIONAL FUNCTIONS .................................................................................... 10
8.1. HOLD FUNCTION ....................................................................................................................... 10
8.2. CHAIN COMPENSATION ........................................................................................................... 10
9. ERROR CODES AND TROUBLESHOOTING ....................................................... 11
10. SPECIFICATIONS .................................................................................................. 11
11. QUICK CONFIGURATION GUIDE ......................................................................... 12

2
User manual OMEGA 804 Series

1. DESCRIPTION AND MAIN FEATURES


Dinacell OMEGA 804 is a control unit to measure, monitor and limit the load of a
elevator besides to monitor the tension of each elevator rope individually.

This system consists of inputs for up to eight sensors and the following inputs and
outputs to interface with the elevator controller: output for display in the cabin,
four relay contacts to inform of the load levels chosen and one input to hold
function, that inhibit load measure during the elevator travel.

2. DISPLAY AND CONTROL BUTTONS




 Show alarms status
Show load and value of
 parameters
   Rope tension monitor

 Show units

  Hold function status

 Control buttons

Functions of control buttons:

a. Enter/exit of the menu and navigate through parameters.


b. Accept and save modified values.

a. When load is shown: Enter in the rope tension monitor function


b. During menu navigation: Enter to modify a parameter.
c. While modifying a parameter: Chose digit to change.

a. During menu navigation: Show the stored value of the selected


parameter.
b. While modifying a parameter: Change the blinking digit
incrementally from 0 to 9.

3
User manual OMEGA 804 Series

3. INSTALLATION AND CONNECTIONS

USB sockets for load cells.


Sensors input
(SWK, SWR, TCA, LCA)

24Vdc version 80-260Vac version


Power supply
input
(Two versions)
24V dc (Non polarity) Earthed 80-260V ac power supply.
It provides two types of output depending on
the CDISP parameter:
1. CDISP = “INCRE”: Progressive display MB-D
Cabin display
output
(two wire connection without polarity).
2. CDISP = “LED”: Under overload it will be an
intermittent voltage of 7,5V (max. 75mA)
with the polarity shown in the figure.
This function will be activated when an input
HOLD input voltage of 24 to 230V (DC or AC) is applied.
(See the ADDITIONAL FUNCTIONS chapter).

Relay
Terminals of the alarm relays.
connections
for alarms (See the alarms section in chapter 7.2)

4
User manual OMEGA 804 Series

4. MENU STRUCTURE
The menu has the cyclic structure shown in the following figure.
Press button for 3 seconds to enter, then press it repeatedly to move from a
parameter to another. Press it for 3 seconds to exit.

Display the value of the measured load



Sets the sensor type (SWK, SWR, TCA and LCA)

Sets the number of sensors to use

Sets measurement units to kg or lb

Initial reference when sensors are not installed on the ropes
(not available when parameter SENSO is set to TCA)

Parameter to adjust measurement with empty car

Parameter to adjust measurement with car loaded

Sets levels of load that change the relays status

Sets the car display type (incremental or LED)

Sets the weight of the compensation chain

5. HOW TO CHECK OR MODIFY PARAMETERS


Once inside menu and display showing the parameter to be viewed or changed:
 Press to check the current value.
 Press to enter to modify the value:
∙ Press to chose the digit to change (blinking) and to change it.
(if there’s no digit blinking, change the value with button directly).
∙ Press twice to save the value.

If button is not pressed the second time before display blink


ends, the changes will not be stored.

After any of these operations, the display shows the current parameter.

5
User manual OMEGA 804 Series

6. INITIAL CONFIGURATION
1. Install the control unit with the information of the INSTALL AND CONECTIONS
chapter, and then power up the unit with the correct voltage (see the
SPECIFICATIONS chapter).

Press
2 sec. Choose
to enter Press type of Press x2
2. Set parameter to enter sensor to save
according value
with the sensors
Display
type that it is shows this
going to use .

Press Choose
3. Set parameter Press number of Press x2
according to enter sensors to save
value
with the number
of sensors that it Display
is going to be shows this
connected.

Press
Press Choose Press x2
to enter “kg” or ”lb” to save
value
4. Set units of measurement.
Display
shows this

Follow next configuration steps


depending on the application.

7. TYPES OF CONFIGURATION DEPENDING ON THE APPLICATION


This system has two modes of working:
a) can be used to adjust ropes tension (WRT)
b) can be used as a load weighing device (LWD).

The operation sets the zero when sensors are not installed on the ropes.
After this, the ropes tension can be measured and adjusted individually.

IREF operation is not available for TCA sensor

6
User manual OMEGA 804 Series

7.1. SYSTEM USED AS A ROPE TENSION MONITOR (WRT)

Make sure that the sensors are not installed on the ropes.

Press Choose
1. Set with the Press “ALL” Press x2
value “ALL”. to enter value to save
value

Display
shows this

∙ Now install sensors on the ropes.


∙ Make sure the cabin is empty and
there’s no weight in the car roof.

Press
Press Choose countdown
to enter seconds
2. Adjust ZERO with
the cabin empty. Display Choose Change
shows this digit digit

Wait
countdown
Press x2 to start
adjustment

Press 3 sec. to
exit menu Press 2 sec.
to enter in Press repeatedly
WRT function to choose sensor
to check
3. Check sensors load
individually entering Display
in WRT function. shows load The sensor chosen is
indicated by a circle
with its number
WRT function helps to
check tension of all ropes
individually. Press 3 sec. to exit
To adjust the tension of the WRT function
ropes, follow the next step.

7
User manual OMEGA 804 Series

4. Adjust tension of ropes with the help of rope tension monitor (WRT) in display,
as it is explained with the next figure.

Ropes with sensors 1 Sensors 7 and 8


and 2 are balanced shows not connected
Ropes with sensors 3, 4, 5
and 6 are NOT balanced

7.2. SYSTEM USED AS A LOAD WEIGHING DEVICE (LWD)


1. Drive the elevator car to the middle of the shaft.
2. Bounce in cabin to insure there’s no friction on guides.
3. Install sensors on the ropes.
Press
repeatedly
Press
3 sec.
to enter Press Choose countdown
to enter seconds

4. Adjust ZERO with


the cabin empty. Display Choose Change
shows this digit digit

Wait
countdown
Press x2 to start
adjustment
Introduce inside the cabin a well-known weight
(minimum 50% of the elevator full load).

Press
Press Enter the value of the real
to enter weight inside the cabin

5. Adjust LOAD with the


cabin loaded. Display Choose Change
shows this digit digit

Wait
countdown
Press x2 to start
adjustment

8
User manual OMEGA 804 Series

Press Press to enter


6. Set alarms.
in alarms
submenu
“Alarms” are the Choose alarm
programmed load Display
shows this
levels that change
the state of relays.
It is not necessary
to introduce weight
in the cabin.
Enter to Keep
Press x2 modify pressed
RELAYS ASSIGNMENT to check
to save value
Alarm1 Relay for Full Load.
Enter the level
Alarm2 Relay for Overload.
Relay for Unlevel
Alarm3 Wire Rope Tension Choose relay Press x2 Choose Change
(Fixed assignment). to validate digit digit
contacts
Additional Relay to “open” or ”close”
activate MB-D, LED,
Alarm4
buzzer or other
warning devices.

Press
Press Choose Press x2
to enter “incre” or ”LED” to save
value
7. Set cabin display
output. Display
shows this

Press 2 sec. Press once to go to the CHAIN parameter.


to exit (See the ADDITIONAL FUNCTIONS chapter).

9
User manual OMEGA 804 Series

8. ADDITIONAL FUNCTIONS
8.1. HOLD FUNCTION
When a voltage in the range 24-230V (DC or AC) is applied in this input, the unit
stops to measure and the last value of weight acquired will be shown in display.

The voltage must be applied when the doors close and the it must be removed
when the doors open. This ensures that the movement of the cabin will not affect
the weighing process and therefore, no relay will be activated during elevator
travel.

Also, when the doors are closed, since no more people will be entering in the
cabin, there is no reason to continue the weighing process. When the doors open,
voltage must be removed from the hold input so that the unit can begin
measuring the load in the cabin.

8.2. CHAIN COMPENSATION


This function allows to compensate the difference of weight between floors
produced by the compensation chain.
The unit needs the HOLD signal active when the doors close to compensate the
weight during the elevator movement.

How to set the chain compensation weight (Max. 200 kg):

Press
repeatedly
Press
3 sec. Enter the value of the
to enter Press weight of compensation
to enter chain (Max 200kg).

Display Choose Change


shows this digit digit

Press x2 to start
Press 3 sec. adjustment
to exit

The default value is zero (00000), this means that


no chain compensation is activated.

10
User manual OMEGA 804 Series

9. ERROR CODES AND TROUBLESHOOTING


When the unit detects some anomaly it will show an error codes of the following:

Important: When an error appears, all alarms are activated and the
elevator remains blocked.

Error description Action


Load cell is not properly connected, it Check the load cells
or its cable is damaged. connection.
Negative overflow. Check the load cell
The load cell is giving a negative signal connection because it should
too high. be no negative charge.
Positive overflow. load cell by another with
Load cell is holding a higher load than higher nominal load.
its nominal value.
Polarity error. This happens when the Check the load cells
unit adjusts the weight with the wrong connection.
load cell polarity, or the weight is not in Adjust the zero and weight
the cabin during the adjustment. again.
Loss of data in memory. The unit must be configured
Notice: When this error appears, every again with the properly
relay will remain in OFF state. values.
Load cell with very low sensibility. Adjust the zero and weight
Usually the unit is wrong adjusted. again.

RESTORING THE FACTORY SETTINGS (Only in case of problems)

Press Press repeatedly Enter Choose Press x2 Press 2 sec.


simultaneously to find “RESET” “YES” to save to exit
value
10. SPECIFICATIONS
24Vdc version 80-260Vac version
Power supply Short-circuitable.
characteristics It is not necessary to replace any fuse.
Nominal voltage 24V dc 80-260V ac
Maximum current 250mA 75mA
Nominal frequency - 50-60 Hz
Relays Contacts Normally Open 250V – 3A
Box IP-50 V0 fireproof plastic.

11
User manual OMEGA 804 Series

11. QUICK CONFIGURATION GUIDE


 Parameters checking or modification
Press repeatedly to find
the desired parameter Modify the value
Press
2 sec.
to enter
Press 2 sec. Check Enter to Change Choose Press x2
to exit value modify digit digit to save
value

 Initial configuration of the unit


1. Make the necessary connections.
2. Set parameter according with the sensors type.
3. Set parameter according with the number of sensors.
4. Set of measurement (“kg” or ”lb”).

Now follow steps a) or b) depending on the application:

a) Configuration when system is b) Configuration when system is


working as a rope tension working as load weighing
monitor (WRT) device (LWD)
5. Make sure that the sensors are 5. Drive the elevator car to the
not installed on the ropes. middle of the shaft.
6. Set with the value 6. Bounce in cabin to insure
“ALL”. there’s no friction on guides.
7. NOW, install sensors on the 7. Now, install sensors on the
ropes. ropes.
8. Adjust ZERO with the cabin 8. Adjust ZERO with the cabin
empty. empty.
9. Check sensors load individually 9. Adjust LOAD with a well-known
weight inside the cabin.
pressing button during 3 10. Set desired alarms levels.
seconds and then exit pressing 11. Set cabin display output
button during 3 seconds. (“incre” for progressive display
10. Adjust tension of ropes with or “LED”).
the help of rope tension 12. Set the chain compensation
monitor (WRT) in display. weight (max. 200 kg).

Dinacell Electrónica, S.L. - www.dinacell.com


92-6081-00
C/ El torno, 8 - 28522 Rivas Vaciamadrid - Madrid (SPAIN) 11/05/2012
Tel.: +34 91 300 14 35 – Fax: +34 91 300 16 55

12