STP-DRV-6575
MICROSTEPPING DRIVE
In This Chapter...
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–3
Typical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–4
Wiring Connections and Configuration Switches . . . . . . . . .2–4
Connecting the Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–5
Connecting the Power Supply . . . . . . . . . . . . . . . . . . . . . . .2–6
Connecting the I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–7
SureStep™ Drive Digital Inputs and Outputs . . . . . . . . . . . . . . .2–7
Connecting the Input Signals – STEP and DIR . . . . . . . . . . . . . .2–7
Connecting the Input Signals – EN Input . . . . . . . . . . . . . . . . . .2–8
Connecting the Fault Output . . . . . . . . . . . . . . . . . . . . . . . . . . .2–9
Drive Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–10
Drive Configurations Settings . . . . . . . . . . . . . . . . . . . . . . . . . .2–10
Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–12
Choosing a Power Supply . . . . . . . . . . . . . . . . . . . . . . . . .2–13
Mounting the Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–14
Dimensions and Mounting Slot Locations . . . . . . . . . . . . .2–14
SureStepTM Stepping Systems User Manual
Chapter 2: SureStep™ STP-DRV-6575 Microstepping Drive
Specifications
SureStep™ Microstepping Drive Specifications
Part Number STP-DRV-6575
Input Power 24–65 VDC (external power supply required; fuse at 7A fast-acting)
Output Current 0.5–7.5 A/phase (peak of sine)
Current Controller Dual H-bridge digital MOSFET, 4-quadrant PWM at 20 kHz
5–24 VDC nominal (range: 4–30 VDC); (5mA @ 4V; 15 mA @ 30V);
Optically isolated, differential. Minimum pulse width = 0.5µs.
Step
Maximum pulse frequency = 150 kHz or 2MHz (user selectable).
Function = Step or Step CW pulse.
5–24 VDC nominal (range: 4–30 VDC); (5mA @ 4V; 15 mA @ 30V);
Input
Optically isolated, differential. Minimum pulse width = 0.5µs.
Signals Direction
Maximum pulse frequency = 150 kHz or 2MHz (user selectable).
Function = Direction or Step CCW pulse.
5–24 VDC nominal (range: 4–30 VDC); (5mA @ 4V; 15 mA @ 30V);
Enable Optically isolated, differential.
Function = disable motor when closed.
Output 30 VDC / 80mA max, optically isolated photodarlington, sinking or sourcing.
Fault
Signal Function = closes on drive fault.
Rotary Switch Selectable
Select motor based on part number, or by motor current.
Function
Step Pulse Step and Direction: Step signal = step/pulse; Direction signal = direction.
Jumper Type Step CW & CCW: Step signal = CW step; Direction signal = CCW step.
Selectable
Functions Step Pulse
Select 150 kHz or 2MHz
Noise Filter
Reduce power consumption and heat generation by limiting motor running current
Current
to 100%, 90%, or 80% of maximum. Current should be increased to 120% if
Reduction
microstepping. (Torque is reduced/increased by the same %.)
Idle Current Reduce power consumption and heat generation by limiting motor idle current to
DIP Switch Reduction 90% or 50% of running current. (Holding torque is reduced by the same %.)
Selectable Anti-resonance and damping feature improves motor
Load Inertia
Functions performance. Set motor and load inertia range to 0–4x or 5–10x.
Step For smoother motion and more precise speed, set the pulse step resolution to
Resolution 20000, 12800, 5000, 2000, 400 smooth, 400, 200 smooth, or 200 steps/rev.
Automatically rotate the motor back and forth two turns in each direction in order
Self Test
to confirm that the motor is operational.
Drive Cooling Method Natural convection (mount drive to metal surface)
Mounting Use (2) #6 screws to mount wide or narrow side to metal surface
Motor & Power Supply: Screw term blocks Phoenix Contact 1757051 (30–12AWG)
Removable Connectors
Signals: Screw terminal blocks Phoenix Contact 1803633 (30–14 AWG)
Weight 10.8 oz [306g] – (including mating connectors)
Operating Temperature 0 to 85 °C [32 to 185 °F] – (interior of electronics section)
Ambient Temperature 0 to 50 °C [32 to 122 °F] – (drive must be mounted to suitable heat sink)
Humidity Maximum 90% non-condensing
Agency Approvals CE (EMC & LVD); RoHS
VDC +
Logic Motor
+
VDC –
A+
A– STP-
B+ DRV-xxxx
STP-PWR-xxxx B– Stepper Drive
FAULT+
Terminal Block
EN–
1757051
EN+
DIR–
DIR+
STEP–
STEP+
DIP Switches
B–
Terminal Block
Removable
B+
1803633
Power
A–
A+
V–
V+
External wiring is connected using two separate pluggable screw terminal connectors. The
power connections share a six-position connector, and the digital inputs and output share an
eight-position connector.
Red 4
A+
lead
motor
A–
White
Green Black
B+ B–
4 Leads
All AutomationDirect SureStep™ motors are four lead bipolar step motors.
Red/ Red/
Red Black Wht Red Black Wht
B– n/c B+ B– B+ n/c
Step motor wire lead colors vary from one manufacturer to another.
Step motor wire lead colors vary from one manufacturer to another.
Fuse* EMI**
Step + * External fuse not req'd when
Motor using an STP-PWR-xxxx P/S; fuse is internal.
Power VDC
Supply – ** CE use requires an EMI line filter.
V–
Many high speed indexers have differential (also known as line-driver) outputs.
Warning: 24VDC is the maximum voltage that can be applied directly to the
standard speed EN input. If using a higher voltage power source, install resistors to
reduce the voltage at the input. Do NOT apply an AC voltage to an input terminal.
+ EN+
5-24 VDC
Power STP-DRV-6575
switch or relay Drive
Supply (closed = logic low)
- EN–
+ EN+
+ output
5-24 VDC EN–
Power NPN
Supply Proximity STP-DRV-6575
- - Sensor Drive
+ + output EN+
Leave the ENABLE input unconnected if you do not need to disable the amplifiers.
FAULT+ Load +
5-24 VDC
STP-DRV- Power
6575 Drive Supply
FAULT– -
Connecting FAULT Output as Sourcing Output
FAULT+ +
5-24 VDC
STP-DRV- Power
6575 Drive Supply
FAULT– Load -
Do not connect more than 30 VDC. Current must not exceed 80 mA.
Drive Configuration
You need to configure your drive for your particular application before using the
drive for the first time. The SureStep STP-DRV-6575 microstepping drive offers
several features and configuration settings, including:
ON 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7
20000 12800 5000 2000 400 400 200 200
SMOOTH SMOOTH
ON 1 2 1 2 1 2 1 2 ON 3 3 ON 4 4 ON 8 8
100% 90% 80% 120% 5-10x 0-4x 50% 90% ON OFF
(Use 120% when microstepping)
Jumper Settings
Jumpers S3 and S4 are located on the internal circuit board, and they can be
accessed by removing the drive’s front cover.
Remove connectors and cover to access Jumpers
S3 and S4. They are located on the upper
left corner of the circuit board.
Jumper S4:
Step Pulse Noise Filter
Jumper S3:
Step Pulse Type
Jumper S3 – Step Pulse Type
• Jumper in “1-2” position – Step & Direction (factory default)
• Jumper in “1-3” position – Step CW / Step CCW
Jumper S4 – Step Pulse Noise Filter
• Jumper in “1-2” position – 2MHz
• Jumper in “1-3” position – 150 kHz (factory default)
Rotary Switch Settings – Motor/Current Settings
STP-DRV-6575 Motor Selection Table
Motor Data Drive Configuration Data
Motor Current
Torque (oz·in)
(Arms/phase)
Drive Current
(peak sine A)
Roter Inertia
Inductance
Resistance
STP-MTR
Rotary Switch
-xxxx(D)
Holding
(oz·in2)
(g·cm2)
(mN·m)
Torque
Inertia
Motor
(mH)
Position
(Ω)
F0 1
-23079 2.8 276 2.60 3.82 1.10 1949 475 3.36 A
-34066 2.8 434 7.66 7.70 1.11 3065 1402 3.36 B
H-23079 5.6 287 2.60 1.18 0.40 2025 371 6.72 C
H-34066 6.3 428 7.66 1.52 0.25 3021 1402 7.56 D
H-34097 6.3 803 14.80 2.07 0.03 5668 2708 7.56 E
H-34127 6.3 1292 21.90 4.14 0.49 9123 4008 7.56 F
Alarm Codes
In the event of a drive fault or alarm, the green LED will flash one or two times,
followed by a series of red flashes. The pattern repeats until the alarm is cleared.
STP-DRV-6575 Alarm Codes
Status LED Alarm Code Error
solid green no alarm; motor disabled
flashing green no alarm; motor enabled
flashing red configuration or memory error *
1 green, 4 red power supply voltage too high **
1 green, 5 red over current / short circuit ** †
1 green, 6 red open motor winding **
2 green, 3 red internal voltage out of range **
2 green, 4 red power supply voltage too low *
* Does not disable the motor.
The alarm will clear about 30 seconds after the fault is corrected.
** Disables the motor. Cannot be cleared until power is cycled.
† The over-current/short-circuit alarm typically indicates that an electrical fault exists
somewhere in the system external to the drive. This alarm does not serve as motor
overload protection.
SureStep™ STP-PWR-xxxx power supplies from AutomationDirect are the best choices
of DC power supply to use with SureStep™ STP-DRV-xxxx(D) microstepping drives.
2.98 0.89
[75.6] [22.7]
1.04
[26.5]
4.42
[112.3]
0.22 0.41
2 X R0.09
[5.6] [10.5]
[R2.2]
0.35 1.30
[8.9] [33.0]