Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Modbus GW PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MODBUS-GW™

Modbus Gateway

Integration & Graphics

General

The Modbus Gateway provides a


communication link between networks
that use the Modbus/TCP communication
protocol and Fire Alarm Control Panels
(FACPs) resident on an NFN network.

The NFN network communicates with the


Modbus Gateway through a NOTI-FIRE-NET
network via the network port on any NCM.
The Modbus communication protocol is
consistent with Modbus Application
Protocol Specification V1.1b.
• Support reads of up to 100 registers at a
The Modbus Gateway Configuration Tool, a time. Analog values can be read 10
programming utility included with the registers at a time.
Modbus Gateway assembly, is used to • Receive configuration data from the
configure the Modbus Gateway. The Modbus Gateway Configuration Tool.
Modbus Gateway is designed to need very • Log diagnostic information.
little configuration. In most applications • Send standard Modbus exception
you will only need to enter the TCP/IP responses.
settings for your network and the nodes • Reduce configuration time by self
you would like to monitor. The gateway configuring all nodes andpoints.
will automatically map all the configured
points and supply you with a user friendly MODBUS MASTERS COMPATIBLE
comma separated value report that defines
the mapping. • The Modbus Gateway was designed to be
compatible with standard Modbus/TCP
Features masters.
• Support one-byte Unit IDs.
• Compatible with standard and high • Have configurable polling times.
speed NOTI-FIRE-NET • The Modbus Gateway supports one
• Monitor four (4) compatible NFN or Modbus Master.
HS-NFN nodes not including the Modbus
Gateway node itself. PANEL COMPATIBLE
• Allows remote control of FACP
• Provide data such as event type, The Modbus Gateway was designed to be
active/inactive, enabled/disabled, compatible with the following panels:
acknowledged/unacknowledged, device
type and system troubles. • AFP-2800
• NFS2-3030

Page 1 of 2 DOC-02-097
System Architecture & Requirements NETWORK COMPONENTS

An Internet or Intranet IP network • RJ45 to RJ45 standard Ethernet network


connection is required to configure the cable customer's internet or intranet
Modbus Gateway, and to connect it with connection to Modbus Gateway
Modbus clients. The Internet or Intranet IP • NFN network version 5.0 or above (sold
network connection must meet the separately)
following requirements. • High Speed Network Communication
Module: HS-NCM-W/SF/MF board used
• Private or Business LAN to facilitate network communication
• Static IP address required between the Modbus Gateway and a
• Standard 100Base - T connection High Speed NFN net-work or Network
• Required Ports(s): 502 Communication Module: NCM-W/F
board used to facilitate network
REQUIRED EQUIPMENT communication between the Modbus
Gateway and an NFN network.
• MODBUS-GW- NFN to Modbus
Embedded Gateway.
• Network Control Module CUSTOMER SUPPLIED EQUIPMENT
• NFN Network - Version 5.0 or above
• Modbus Configuration Tool • Windows XP based computer to run the
Modbus Configuration Tool.

NFN Network

IP Network

MODBUS-GW HS-NCM-W/SF/MF
or NCM-W/F

AFP-2800 AFP-2800
AFP-2800

IP Network AFP-2800
MODBUS-GW HS-NCM-W/SF/MF
or NCM-W/F

© 2009 by Honeywell International Inc. All rights reserved.


Unauthorised use of this document is strictly prohibited.

This document is not intended for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information contact your nearest Notifier Sales Office or Distributor
www.notifier.com.au

Page 2 of 2 DOC-02-097

You might also like