A Clear Path To Electrical Power Excellence!
A Clear Path To Electrical Power Excellence!
A Clear Path To Electrical Power Excellence!
Electrical Power
Excellence!
CW500
Power Quality Analyzer
Bulletin CW500-01EN
Electrical power
measurement is a key for
innovation.
The Yokogawa CW500 is a
portable power meter that
Features
utilizes a current clamp
sensor for use in the field
enabling consumption
and power quality • Power Measure and Logging
measurement of the power • Power Quality Measuring
line.
• User Support
By the navigation screen • Analysis of Data and Report Generation
of the unit, the connection
setting and detail setting of
the unit is simple and direct
by following the screens. Power Measuring and Logging
Keys which directly turn on • Simultaneously measures 3 CH Voltage input, 4 CH current
desired measuring screens clamp-on probe input, 2 CH DCV input.
allow comfortance at the • Displays value list or trend graph screen of Instantaneous/
use of field. Average/Maximum/Minimum of Voltage/Current/Power/Power
factor/Phase Angle/Phase Advanced Capacitance Calculation
Stored measured data are and DCV input.
easily accessed by a click • Integration Value of Active/
on the file with included Reactive/Apparent Energy
PC software. is each displayed by
consumption and generation.
• Demand value can be
monitored by screens of
present power consumption
Simplified power compared to aimed demand
measuring – Several direct power value.
keys keep you simple and
direct access to Voltage/
Current/Power/Power factor/
Phase Angle/Frequency/
Integrated power/Demand by
values or by a trend graph.
User Support
Firmly capture line Quick Start Guide Function:
power quality issue – • Start Guide Function supports secure wiring and setting
Captures short period power before measuring.
malfunction conforming IEC • Automatically recognize the type of current clamp-on probe.
6100-4-30 Class S.
Vector Display:
User support – Function of • Indicates Voltage and Current phase difference and values
Quick Start Guide to support between input channels of voltage and current.
secure wiring and setting of • Checks whether the wiring is appropriate or not.
units.
Power Quality Measuring Analysis of Data and Report Generation
Function
Short period power line malfunctions such as voltage swells/dips/interruptions/transient overvoltage or inrush currents, or
long period such as harmonic distortion, flicker may damage or reset your devices.
The CW500 helps to identify each of those short period malfunctions, by recording occurrence time, occurrence finish time
and waveforms. Additionally there is a digital output on occurrence.
Long period malfunctions can be analyzed by harmonics, flicker, waveform or checking on the unbalance rate calculation
for 3 phase measurement.
All data can be finalized to a report format with included software.
The CW500 conforms to the IEC standard of 61000-4-30 Class S.
Increase and decrease on certain phases could cause Pst (1 min), Pst or Plt is
Flicker
flickering distortion on voltage and currents. measured.
Capture temporary power line issues Capture continuous power line issues
Various kind of power issues are captured by high Harmonic Measuring
sampling rate of 24 µs and overlapping RMS measuring • Displays components of up to the 50th Harmonics
by half cycles. They are recorded as an event by occurred contents by individual channel or overall by graph or list
time, occurrence finish time and waveforms are recorded. • Displays the maximum occurred point on graph.
Voltage swell
Voltage dip
Voltage Interrupt
Transient overvoltage
Inrush Current Graph display List display
List display
Waveforms and
measured data Waveform
are stored on a SD
memory card. Displays voltage and
current waveform by all or
Main operation individually.
It can be zoomed in and out
by vertical or horizontal with
rate selection below.
Vertical rate: 0.1, 0.5, 1, 2, 5, 10
Horizontal rate: 1, 2, 5, 10
Start of guidance
PUSH “START/STOP”key
and select “Quick start
guide”.
Recording item selection will Example diagram
be displayed. of power supply
3T
identification will be executed N
Recording setting
Set recording interval time Multiple line measuring
and recording time or period.
4 system load measuring
Maximum of 4 systems is capable for 1 phase 2 line
Maximum of 2 systems is capable for 1 phase 3 line or 3
phase 3 line.
9 Software for Analysis and Setting (Free) CW500Viewer
Data analysis , making reports of data, making setting file and doing a real time measuring can be easily done with the
CW500Viewer.
The data can be transferred by SD memory card, USB communication or Bluetooth communication (for USA, Canada,
Japan only).
USB
communication
Bluetooth
communication*
Example of multiple
graph display
SD Memory Card
Example of setting display
Application
Voltage/Current/
Power/Power factor/
Demand/
Leakage current Analog input 2 CH
11 Improving power line of a printing Others
factory by measuring harmonics
(Printing factory) Improvement of Power factor for power efficiency
CW500 can calculate the appropriate condensor value by
Purpose: Investigation of the cause of periodic setting the aimed power factor value.
malfunction for printing machine. By setting the appropriate advanced condensor and
Harmonics distortion on line could be the reason? improving the power factor, users will benefit for power
Measuring: CW500 merit saving with less load current and improve the capacity of
• Compact size and easy to carry. the whole power system.
• Up to 50th Harmonics measuring.
• Long term recording
Result: Confirming high level harmonic contents
on 5th and 7th.
Found harmonics were generated by internal
assets.
Especially 5th harmonics damages the direct reactor
of condensor for improving power factor
Found
[Before] cause
[After]
Confirmation
of inflow
harmonics
500kV transformers
of factory “A”.
External Appearance CW500
External Appearance
12
17
18 19
13
14
15
16
5
1 9 10 11
6
2
7
3
8
4
12
7 Power quality screen switch 12 Cursor and Enter Key 19 Clamp-on probe connection
Accessories
Photo
Output AC 50 mV
AC 500 mV AC 500 mV AC 500 mV AC 500 mV AC 500 mV
For each range
voltage (25 mV/A) AC 500 mV
50 Hz/ ±1.0% rdg ±0.5% rdg ±0.5% rdg ±0.5% rdg ±0.5% rdg ±0.8% rdg
60 Hz ±0.05 mV ±0.1 mV ±0.1 mV ±0.1 mV ±0.1 mV ±0.2 mV
Level
40 Hz to ±2.0% rdg ±0.8% rdg ±1.0% rdg ±0.8% rdg ±1.0% rdg ±1.5% rdg
±1.0% rdg*
1 kHz ±0.1 mV ±0.2 mV ±0.2 mV ±0.2 mV ±0.2 mV ±0.4 mV
Accuracy
Max Circuit AC 300 Vrms AC 300 Vrms AC 300 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms AC 600 Vrms
voltage
approx. approx. approx. approx. approx. approx. approx.
70(W) × 120(H) × 52(W) × 106(H) × 60(W) × 100(H) × 73(W) × 130(H) × 81(W) × 128(H) × 73(W) × 130(H) × 61(W) × 111(H) ×
Dimension 25(D) mm 25(D) mm 26(D) mm 30(D) mm 36(D) mm 30(D) mm 43(D)mm
(excluding pointed part)
Weight approx. 230 g approx. 170 g approx. 160 g approx. 240 g approx. 260 g approx. 170 g approx. 950 g
Extension code Power supply adapter Portable case (for CW500) Conversion Cable (Banana-DIN)
98082*1 98031*2 93047 99073*2, 3
*1 Extension code 98082 corresponds to below current probe. 96060, 96061, 96062
*2 Non-CE product. Not available for CE marking necessary region.
*3 The following clamp-on probe are able to be connected. 96030, 96033, 96036
Specifications CW500
Specifications
14
YMI-KS-MI-SE01