Casella Cel 630 Datasheet v2 PDF Us Version
Casella Cel 630 Datasheet v2 PDF Us Version
Casella Cel 630 Datasheet v2 PDF Us Version
Digital
Sound Level Meter
www.casellasolutions.com
Applications Key Features Environmental Noise Measurements
Occupational Noise Measurement • Ideal for environmental or occupational monitoring Data can be marked to signify any significant events, the data
• Workplace noise assessments according • Easy to use switch-on-and-go functionality from which can be removed afterwards in insight software.
to ISO9612, OSHA 29CFR 1910.95 • Latest digital technology with a high resolution Up to 60 hours of audio files can be stored, commonly used for
• Selection of hearing protection color TFT display noise source identification. Stored audio can be played back • Simultaneous broadband and
• Calculation of noise exposure • Pre-configured set-ups for occupational and on the instrument using headphones or downloaded to Casella frequency measurement
• Ensuring compliance with workplace noise legislation environmental measurements insight software. • Data markers
• Voice notes to annotate measurements • Back erase function
For unattended monitoring, event mode (CEL-633) allows trigger
• Audio (WAV) recording • Real-time frequency analysis
Environmental Noise Measurement levels (dB) to be set, so additional data (e.g. Leq, Lmax) is stored
• Single measurement range up to 140dB, no range • Single measurement range
• Boundary noise assessments together with the audio file for later play back or analysis, as well
adjustment required • Triggered ‘event’ capture
• Noise nuisance complaints as a profile down to 10ms intervals.
• Data markers, back erase function and audio recording A dedicated
• Measurements according to ISO1996, BS4142 An environmental noise monitoring kit is available which protects environmental kit
• Level triggered events for transient measurements is available
• UK Construction Section 61 notices the instrument and microphone from the weather and allows
• Real-time octave and ⅓ octave measurements
unattended monitoring for up 10 days.
• Simultaneous measurement of all parameters with all
frequency and time weightings
• Class 1 or Class 2 models available
• 2GB memory for more than 1 year of data storage
• Removable pre-amp
• Environmental outdoor kit available
• Replay voice notes and event audio analyzed and graphed and
annotated as copied to other
• Intuitive user interface required applications
Technical Specification
Standards: IEC61672: 2002 Class 1 and 2, ANSI S1.4: Type 1 and 2 Measured Parameters
(1983) Broadband: LXY, LXYmax, LXYmin, LXeq, LXpeak, Lavg, LC-LA, LXIeq, LTM3, LTM5, LAE.
Filters: IEC61260: Class 0, ANSI S1.43: (1996) Workplace dose values are calculated within insight
Note: IEC61672 replaces 2 obsolete standards, IEC60651 and software.
IEC60804 Octaves and ⅓ octaves: LXY, LXeq, LXYmax, 5x Ln% (on CEL-633). Where X is the
General frequency weighting A, C or Z and Y represents time
Measurement range: 20-140dB RMS (143.3dB peak) weighting Fast (F), Slow (S) or Impulse (I). All weightings
simultaneously measured where appropriate.
Total Noise floor: 19dB(A) Class 1, 25dB(A) Class 2
CEL-633 model additionally stores 5x Ln values in broadband and octave modes.
Time weightings: Fast, Slow and Impulse simultaneously
For time history data, all parameters are logged for period times plus 6 selectable
Frequency weightings: A, C and Z (un-weighted) simultaneously
profile parameters (plus 5x Ln values on CEL-633).
Frequency bands: 11 Octave bands 16Hz-16kHz (B&C models)
Memory
33 Octave bands 12.5Hz-20kHz (C models)
Memory: 2GB (>1 year logging when set to 1 second interval, 999 runs). All
Amplitude weighting (Q): 3, 4 and 5 simultaneously
parameters stored and accessible via Casella insight. Total measurement runs: 999.
Back erase: Last 10s in cumulative mode (all models)
Events: 999 events/run. 10 hours of audio recording in high quality mode, 60
Timers: Duration 1s-24h,
hours in low quality mode. For long term unattended monitoring the CEL-630
On/Off timers: 6 sets with selectable times and a repeat function takes a new run daily for up to a total of 400 days.
Physical Audio Recording
Tripod mount: ¼" Whitworth socket Low Quality: 8,000 samples/s @ 8bit (64kb/s), up to 4kHz
Batteries: 3x AA Alkaline, 10-15 hours dependent on back light High Quality: 24,000 samples/s @ 8 bit (192kb/s), up to 12kHz
External power: 9-14V DC at 150mA Environmental
Weight: 332g including batteries Operating 0 to 90%RH in the absence of condensation
Size: 230x72x31mm inc preamp and microphone Conditions: Temperature of -10 to +50°C (Class 1) and 0 to 40°C (Class 2)
Atmospheric pressure of 65 to 108kPa.
Languages
User interface can be changed via the menu: English, French, German,
Spanish, Italian, Portuguese, Chinese.