Specifications
Standards and EC Directives UL/CSA (UL 508, CSA C22.2 No. 14)
A300
Conforms to the following EC Directives:
• Machinery Directive Rated Carry Current (A) Volt-amperes (VA)
• Low Voltage Directive voltage current Make Break Make Break
• EN 1088
120 VAC 60 6
• EN 60204-1 10 A 7,200 720
• GS-ET-19 240 VAC 30 3
Q300
Certified Standards
Rated Carry Current (A) Volt-amperes (VA)
Certification voltage current Make Break Make Break
Standard File No.
body
125 VDC 0.55 0.55
Consult your 2.5 A 69 69
EN 60947-5-1
TÜV SÜD representative for 250 VDC 0.27 0.27
(certified direct opening)
details.
UL *1 UL 508, CSA C22.2 No.14 E76675 Solenoid Coil Characteristics
CQC (CCC) GB14048.5 2003010305064267 Item Type 24 VDC 110 VAC 230 VAC
KOSHA *2 EN60947-5-1 2005-196 Rated operating +10% 110 VAC 230 VAC
voltage (100% ED) 24 VDC -15%
±10% ±10%
*1. Certification for CSA C22.2 No. 14 is certified by the UL mark.
*2. Only certain models have been certified. Approx. Approx. Approx.
Current consumption
200 mA 50 mA 30 mA
Insulation Class Class F (130°C max.)
Certified Standard Ratings
Indicator Characteristics
TÜV (EN 60947-5-1), CCC (GB14048.5)
Item Type LED
Item Utilization category AC-15 DC-13
Rated voltage 10 to 115 VAC/VDC
Rated operating current (Ie) 3A 0.27 A
Current consumption Approx. 1 mA
Rated operating voltage (Ue) 240 V 250 V
Color (LED) Orange
Note: Use a 10 A fuse type gI or gG that conforms to IEC 60269 as a short-
circuit protection device. This fuse is not built into the Switch.
www.sti.com/info G15
D4NL Safety Interlock Switches
Connections
Contact Form
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per GS-ET-19).
G16 www.sti.com/info
D4NL Safety Interlock Switches
Switches
D4NL-□□□□-B
8
15.5
30.5
Pre-travel distance
Red
Black Four, head mounting screws
15.3 Operation Key
29 Operating D4NL-□□□□-
Three, 4.3-dia. holes
10.0 6.5 characteristics BS
4 Key insertion force
15 N max.
Key extraction
28.5 4.4
Dummy cap 32±0.2 30 N max.
Indicator force
UNLOCK Pre-travel distance 9 mm max.
(13.3)
6.5 (95) Movement before
LOCK
(32.3) 3 mm min.
29 55±0.2 being locked
59 (55.8)
0.5 Five, cover
mounting screws (3)
4
G
(10) UNLOCK LOCK
Conduit opening
D4NL-□□□□-B4
8
15.5
30.5
Pre-travel distance
Red
Black Four, head mounting screws
15.3 Operation Key
29
Three, 4.3-dia. holes Operating D4NL-□□□□-
10.0 6.5
characteristics B4
4
Key insertion force 15 N max.
Dummy cap Key extraction force 30 N max.
28.5 4.4 32±0.2
Indicator
Pre-travel distance 9 mm max.
UNLOCK
(13.3) Movement before
6.5 (95) 3 mm min.
LOCK
(32.3) being locked
29 55±0.2
59 (55.8)
0.5
Five, cover (3)
mounting screws
4
Conduit opening
Notes:
1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application.
www.sti.com/info G17
D4NL Safety Interlock Switches
D4NL-□□□□-BS 15.5
8
30.5
Pre-travel distance
Red Four, head mounting screws
Black 15.3 Operation Key
29
Three, 4.3-dia. holes
10.0 6.5 Operating D4NL-□□□□-
4 characteristics BS
UNLOCK LOCK
Conduit opening
G D4NL-□□□□-B4S
8
15.5
30.5
Pre-travel distance
Four, head mounting screws
15.3 Operation Key 29
Three, 4.3-dia. holes
10.0 6.5 Operating D4NL-□□□□-
Red
Black 4
characteristics B4S
Key insertion force 15 N max.
Release key
28.5 4.4 32±0.2 Key extraction force 30 N max.
Indicator
UNLOCK Pre-travel distance 9 mm max.
(13.3)
(95)
6.5 (32.3) Movement before
LOCK 3 mm min.
29 (31.5) 55±0.2 being locked
59
(55.8)
0.5 Five, cover
mounting screws (3)
4 Notes:
1. Unless otherwise specified, a tolerance
0.5 (30.7) 6.5
Cap screw of ±0.4 mm applies to all dimensions.
35.5 (57.9) (15.3) 2. There are fluctuations in the contact
5 79±0.2 4.5 29
ON/OFF timing for Switches with multiple
Releasing tool (88.5)
(provided)
Dummy poles (2NC, 2NC/1NO, or 3NC). Confirm
M8 hexagonal material cap Conduit cap
or equivalent performance before application.
8 10.5
UNLOCK LOCK
21 Conduit opening
Operation Keys
D4DS-K1 17.5 28 D4DS-K3 14 28 9 dia. Angle adjustment bolt
4 8 dia.
13
4.5 dia.
7 4.3
13 30 40 56
30 15 13
20°
Black
7 Four, 2.15R
2 2
6.3
15
D4DS-K2 10.5 D4DS-K5 20.9 28 24.6 Mounting Holes
6 22.5 (Enlargement)
9 28 7 4 17
15
4.5
30 13 15 15°
8
43 41 30 55
7 13
2 4.3
Four, 2.15R 41 43
Black 18° 6.5 (7)
18
G18 www.sti.com/info
D4NL Safety Interlock Switches
Vertical
insertion radius:
R ≥ 200
G
49.5 min 52.0 max
Key insertion position (36)
15 Center
tolerance of 45.5 min 48.0 max
key hole: ± 1 Key insertion position (36)
Vertical
insertion radius:
R ≥ 200
www.sti.com/info G19
D4NL Safety Interlock Switches
Center
(40)
tolerance of
key hole: ± 1 50.5 min 53.0 max
Key insertion position
(36)
Vertical
insertion radius:
R ≥ 200
Center Horizontal
Center tolerance of insertion radius:
key hole: ± 1 40
(28.5) tolerance of R ≥ 50
key hole: ± 1
D4NL + D4DS-K5
(with Front-inserted Operation Key)
51.9 min 54.4 max
Red Key insertion position
Black
(30.5)
D4NL + D4DS-K5
(with Top-inserted Operation Key)
(41 or 43) 55
Center
Horizontal
tolerance of Red Center (8) insertion radius:
key hole: ± 1 Black tolerance of
R ≥ 50
key hole: ± 1
20.9
Horizontal
insertion radius:
R ≥ 50 57.4 min 59.9 max
Key insertion position
Vertical
insertion radius: (36)
R ≥ 50
51.9 min 54.4 max
Key insertion position (30.5)
Center
tolerance of
key hole: ± 1
Center Horizontal
(28.5) tolerance of 43±0.1 insertion radius:
key hole: ± 1 R ≥ 50
M20-NPT Adapter
57.4 min 59.9 max
Key insertion position
(36)
G20 www.sti.com/info
D4NL Safety Interlock Switches
Application Examples
G9SA-321-T□ (24 VAC/VDC) + D4NL-□A□A-□, -□A□B-□, -□A□C-□
(Mechanical Lock Type) Circuit Diagram (Manual Reset)
KM2
S2
S4
42 54
S1: Safety Limit Switch
41 53 with direct opening mechanism
12 (D4B-N, D4N, D4F)
34
S2: Guard Lock Safety-door Switch
11 33 S3: Reset switch
S4: Lock release switch
KM1 and KM2: Magnetic Contactor
PLC M: 3-phase motor
PLC
Guard
S1 Feedback loop
OPEN
KM1
S3 KM2
Stop signal
1 3
TH K3 4
a K1 K2 K3 1
SA 2
a K4 3
4
K1 OffDelay Control 2 K1 JP 5
b K4 5 6
K2 Timer Circuit
K2
b
6
PE T21 T23 T22 A B 14 24 34 44 54 62
KM1 KM2
Guard opens
Timing Chart
Limit switch S1 Operation
Guard Lock instruction
Motor controller
Safety-door
Switch S2
Lock release
signal KM1
S4
Guard can be opened
KM2
Stop signal
Reset switch
S3
K1 and K2
(NC) M
K1 and K2
(NO)
K3 and K4
(NC)
K3 and K4
(NO)
KM1 and KM2
(NC) Note: The above example circuit is for Category 3.
KM1 and KM2
(NO)
Operation
instruction
Motor rotation
OFF-delay time
www.sti.com/info G21
D4NL Safety Interlock Switches
Ordering
Model Number Structure
G22 www.sti.com/info
D4NL Safety Interlock Switches
Ordering (continued)
List of Models
Switches with direct opening mechanisms (Operation Keys are sold separately)
Contact configuration
(door open/closed
Release detection switch and
Head Release Solenoid voltage/ Lock and release
key lock monitor switch Conduit opening Model
material key type indicator types
position contacts) (slow-action)
Certified direct opening
NC contact
M20 D4NL-4AFA-B
1NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4AFA-B-NPT
adaptor
M20 D4NL-4BFA-B
1NC/1NO+2NC M20 with 1/2” NPT
D4NL-4BFA-B-NPT
adaptor
M20 D4NL-4CFA-B
2NC+1NC/1NO M20 with 1/2” NPT
D4NL-4CFA-B-NPT
adaptor
M20 D4NL-4DFA-B
2NC+2NC M20 with 1/2” NPT
D4NL-4DFA-B-NPT
Mechanical lock adaptor
Solenoid release M20 D4NL-4EFA-B
2NC/1NO+1NC/1NO M20 with 1/2” NPT
adaptor
D4NL-4EFA-B-NPT G
M20 D4NL-4FFA-B
2NC/1NO+2NC M20 with 1/2” NPT
D4NL-4FFA-B-NPT
adaptor
M20 D4NL-4GFA-B
3NC+1NC/1NO M20 with 1/2” NPT
D4NL-4GFA-B-NPT
adaptor
M20 D4NL-4HFA-B
Solenoid: 3NC+2NC M20 with 1/2” NPT
D4NL-4HFA-B-NPT
24 VDC adaptor
Plastic Bottom Standard
Orange LED: M20 D4NL-4AFG-B
10 to 115 VAC/VDC 1NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4AFG-B-NPT
adaptor
M20 D4NL-4BFG-B
1NC/1NO+2NC M20 with 1/2” NPT
D4NL-4BFG-B-NPT
adaptor
M20 D4NL-4CFG-B
2NC+1NC/1NO M20 with 1/2” NPT
D4NL-4CFG-B-NPT
adaptor
M20 D4NL-4DFG-B
2NC+2NC M20 with 1/2” NPT
Solenoid lock D4NL-4DFG-B-NPT
adaptor
Mechanical
release M20 D4NL-4EFG-B
2NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4EFG-B-NPT
adaptor
M20 D4NL-4FFG-B
2NC/1NO+2NC M20 with 1/2” NPT
D4NL-4FFG-B-NPT
adaptor
M20 D4NL-4GFG-B
3NC+1NC/1NO M20 with 1/2” NPT
D4NL-4GFG-B-NPT
adaptor
M20 D4NL-4HFG-B
3NC+2NC M20 with 1/2” NPT
D4NL-4HFG-B-NPT
adaptor
www.sti.com/info G23
D4NL Safety Interlock Switches
Ordering (continued)
List of Models (continued)
Switches with direct opening mechanisms (Operation Keys are sold separately)
Contact configuration
(door open/closed
Release detection switch and
Head Release Solenoid voltage/ Lock and release
key lock monitor switch Conduit opening Model
material key type indicator types
position contacts) (slow-action)
Certified direct opening
NC contact
M20 D4NL-4AFA-B4
1NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4AFA-B4-NPT
adaptor
M20 D4NL-4BFA-B4
1NC/1NO+2NC M20 with 1/2” NPT
D4NL-4BFA-B4-NPT
adaptor
M20 D4NL-4CFA-B4
2NC+1NC/1NO M20 with 1/2” NPT
D4NL-4CFA-B4-NPT
adaptor
M20 D4NL-4DFA-B4
2NC+2NC M20 with 1/2” NPT
D4NL-4DFA-B4-NPT
Mechanical lock adaptor
Solenoid release M20 D4NL-4EFA-B4
2NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4EFA-B4-NPT
adaptor
G M20 D4NL-4FFA-B4
2NC/1NO+2NC M20 with 1/2” NPT
D4NL-4FFA-B4-NPT
adaptor
M20 D4NL-4GFA-B4
3NC+1NC/1NO M20 with 1/2” NPT
D4NL-4GFA-B4-NPT
adaptor
M20 D4NL-4HFA-B4
3NC+2NC M20 with 1/2” NPT
D4NL-4HFA-B4-NPT
adaptor
Plastic
M20 D4NL-4AFG-B4
1NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4AFG-B4-NPT
Special Solenoid: 24 VDC adaptor
Bottom release Orange LED: M20 D4NL-4BFG-B4
key 10 to 115 VAC/VDC 1NC/1NO+2NC M20 with 1/2” NPT
D4NL-4BFG-B4-NPT
adaptor
M20 D4NL-4CFG-B4
2NC+1NC/1NO M20 with 1/2” NPT
D4NL-4CFG-B4-NPT
adaptor
M20 D4NL-4DFG-B4
2NC+2NC M20 with 1/2” NPT
D4NL-4DFG-B4-NPT
Solenoid lock adaptor
Mechanical release M20 D4NL-4EFG-B4
2NC/1NO+1NC/1NO M20 with 1/2” NPT
D4NL-4EFG-B4-NPT
adaptor
M20 D4NL-4FFG-B4
2NC/1NO+2NC M20 with 1/2” NPT
D4NL-4FFG-B4-NPT
adaptor
M20 D4NL-4GFG-B4
3NC+1NC/1NO M20 with 1/2” NPT
D4NL-4GFG-B4-NPT
adaptor
M20 D4NL-4HFG-B4
3NC+2NC M20 with 1/2” NPT
D4NL-4HFG-B4-NPTt
adaptor
M20 with 1/2” NPT
2NC/1NO+1NC/1NO D4NL-4EDA-B4-NPT
Mechanical lock adaptor
Solenoid release M20 with 1/2” NPT
3NC+1NC/1NO D4NL-4GDA-B4-NPT
adaptor
Metal
M20 with 1/2” NPT
2NC/1NO+1NC/1NO D4NL-4EDG-B4-NPT
Solenoid lock adaptor
Mechanical release M20 with 1/2” NPT
3NC+1NC/1NO D4NL-4GDG-B4-NPT
adaptor
G24 www.sti.com/info
Mouser Electronics
Authorized Distributor
Omron:
D4NL-1CFG-B D4NL-1DFG-B D4NL1BFG-B D4NL-2DFA-BS D4NL-2EFA-B D4NL-1AFA-B D4NL-1AFG-B D4NL-
1AFH-B D4NL-1BFA-B D4NL-1BFB-B D4NL-1CFA-B D4NL-1CFB-B D4NL-1DFA-B D4NL-1GDG-B D4NL-2AFA-B
D4NL-2AFG-B D4NL-2AFH-B D4NL-2BFA-B4 D4NL-2BFG-B D4NL-2CFA-B D4NL-2CFG-B D4NL-2DFA-B
D4NL-2DFA-B4 D4NL-2DFG-B D4NL-2EDG-B D4NL-2FDG-B D4NL-2FFG-B D4NL-2HFG-B D4NL-4BFA-B4
D4NL-4EDA-B4-NPT D4NL-4EFG-B D4NL-4GDA-B4-NPT D4NL-4GDG-B4-NPT D4NL-RK D4NL-4FFB-B D4NL-
1BFG-B D4NL-4EDG-B4-NPT