Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Lutron AM 4216

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Mini Vane + Air flow + Air Velocity , CMM, CFM

ANEMOMETER
Model : AM-4216 ISO-9001, CE, IEC1010

FEATURES
* 13 mm dia heavy duty mini vane
with telescope probe available for
high temp. air velocity measurement.
* Air flow : CMM (m^3/min.) and
CFM (ft^3/min.)
* Air velocity :
m/s, ft/min, km/h, knots.
* Air temperature : ℃, ℉.
* 3 air flow mode : Instant, 2/3 Vmax,
Average.
* Low-friction ball vane wheels is
accurate in both high & low
velocities.
* Large LCD with dual display.
* Record max. and min. reading value.
* Data hold.
* Microcomputer circuit.
* Thermistor sensor for temp.
measurement, fast response time.
* RS 232 PC serial interface.
* Separate probe, easy for operation
of the different measurement
environment.

LUTRON ELECTRONIC
mini vane, air flow + air velocity
ANEMOMETER
Model : AM-4216
FEATURES
* 13 mm dia heavy duty mini vane with telescope probe Memory Record maximum & minimum
available for high temp. air velocity measurement. Recall reading value with recall.
* Air flow : CMM ( m^3/min. ) and CFM ( ft^3/min. ) Power off Auto shut off saves battery life
* Air velocity : m/s, ft/min, km/h, knots, mile/h. or manual off by push button.
* Air temperature : ℃, ℉. Sampling Approx. 1 sec.
* 3 air flow mode : Instant, 2/3 Vmax, Average. Time
* Low-friction ball vane wheels is accurate in both high Operating Less than 80% RH.
and low velocities. Humidity
* Large LCD with dual display. Operating Meter 0 ℃ to 50 ℃ ( 32 ℉ to 122 ℉ ).
* Record maximum and minimum reading with recall. Temperature Probe 0 ℃ to 80 ℃ ( 32 ℉ to 176 ℉ ).
* Microcomputer circuit provides special function & offer Data Output RS 232 PC serial interface.
high accuracy. Power Supply Alkaline or heavy duty type DC 9V battery,
* Data hold. 006P, MN1604 (PP3) or equivalent.
* Auto shut off saves battery life. Power Approx. DC 8.3 mA.
* Thermistor sensor for temp. measurement, fast Consumption
response time. Weight 381 g/0.84 LB, main instrument
* Build-in low battery indicator. Dimension Main instrument:
* Operates from 006P DC 9V battery. 180 x 72 x 32 mm ( 7.1 x 2.8 x1.3 inch ).
* RS 232 PC serial interface. Probe :
* Separate probe, easy for operation of the different Vane - 13 mm dia.
measurement environment. Telescope probe length - Max. 600 mm.
* Used the durable, long-lasting components, including a Accessories Instruction manual........................ 1 PC.
strong, light weight ABS-plastic housing case. Included Sensor probe................................ 1 PC.
* Wide applications: use this anemometer to check air Carrying case................................1 PC.
conditioning & heating systems, measure air velocities, Optional RS232 cable..........................UPCB-01
wind speeds, temperature...etc. USB cable............................. USB--01
Windows software, data record
GENERAL SPECIFICATIONS and data acquisition.............. SW-U801-WIN
Circuit Exclusive one-chip of microcomputer
LSI circuit. ELECTRICAL SPECIFICATIONS ( 23 ± 5 ℃ )
Display * 13 mm (0.5") Super large LCD A. Air velocity
display. Measurement Range Resolution Accuracy
* Dual functions display. m/s 0.8 - 12.00 m/s 0.01 m/s ± (2%+0.2m/sec)
Measurement Air velocity: km/h 2.8 - 43.2 km/h 0.1 km/h ± ('2%+0.2km/h)
m/s (meters per second) mile/h 1.8 - 26.8 mile/h 0.1 mile/h ± (2%+0.2mile/h)
km/h ( kilometers per hour ), knots 1.6 - 23.3 knots 0.1 knots ± (2%+0.2knots)
ft/min ( feet per minute ), ft/min 160 - 2358 ft/min 1 ft/min ± (2%+20 ft/min)
knots ( nautical miles per hour ),
mile/h ( miles per hour ),
Air flow: B. Air flow
CMM ( m^3/min. ) Measurement Range Resolution Area
CFM ( ft^3/min. ). CMM ( m^3/min. ) 0-999,900 m^3/min. 0.001-100 0.001-9,999 m^3/min.
Air temperature: ℃/℉ CFM ( ft^3/min. ). 0-999,900 ft^3/min. 0.001-100 0.001-9,999 ft^3/min.
Data hold.
Sensor Air velocity & Air flow
Structure Conventional twisted van C. Air temperature
arm and low friction ball Measuring Range 0 ℃ to 80 ℃/32 ℉ to 176 ℉
bearing design. Resolution 0.1 ℃/0.1 ℉
Temperature : Thermistor. Accuracy 0.8 ℃/1.5 ℉ ( < 60 ℃ )
* Appearance and specifications listed in this brochure are subject to change without notice. 0609-AM4216