PD 1096

DOORS

Minimum height 2.00m

Minimum width 900mm

Maximum width 1200mm


Height of door knob
LOCATION ON PROPERTY
Front setback R1: 4.50m
Side setback R1: 2.00m
Rear setback R1: 2.00m
Distance of eaves from property line 0.75m
MINIMUM ROOM SIZES
6.00sqm
Rooms for human habitation
Minimum dimension of 2.00m
3.00sqm
Kitchen
Minimum dimension of 1.50m
1.20sqm
Bathroom
Minimum dimension of 0.90m
MINIMUM AIR SPACE REQUIREMENTS
3.00 cubic meters (Allot 1.00 sqm
Schools
per person)
Offices and factories 12.00 cubic meters
Habitable rooms 14.00 cubic meters
MINIMUM CEILING HEIGHTS
Naturally ventilated: 2.70m
Ground floor
Artificially ventilated: 2.70m
Naturally ventilated: 2.70m
Second floor
Artificially ventilated: 2.40m
Naturally ventilated: 2.70m
Succeeding floors
Artificially ventilated: 2.10m
Mezzanine 1.80m
LIGHT AND VENTILATION
10% of floor area, but 1.00sqm
Windows for rooms
minimum
5% of floor area, but 240 sq. mm.
Windows for bathrooms
minimum
Minimum dimension of court 2.00m
Min. width of court passageway 1.20m
STAIRS
Riser 200mm maximum

Tread 250mm minimum


Less than 10 OL:0.75m
10-50 OL.: 0.90m
Minimum width
More than 50 OL:1.10m
Minimum headroom 2.00m
Maximum vertical distance between landings 3.60m
Handrail height 800-900mm
RAMPS
Maximum slope
Maximum cross slope
Minimum width No general requirements provided,
Minimum landing length only for ramps located in reviewing
stands, grandstands and
Distance between landings bleachers.

Handrail height
CORRIDORS
1.10m
OCCUPANT LOADS (Area per person)
Place of assembly 0.65 sqm
Standing room
Concentrated use
Less concentrated use
Educational
Classrooms 1.80 sqm
Shop, laboratories, vocational rooms 4.60 sqm
Dry nurseries
Conference rooms, exhibit rooms, gyms 1.40 sqm
Healthcare
Sleeping departments 11.00 sqm
In-patient treatment 22.00 sqm
Hospitals, sanitaria 8.40 sqm
Nursing homes 7.40 sqm
Children's nurseries 3.25 sqm
Residential
Dwellings 28.00 sqm
Hotels, apartments, dormitories 18.60 sqm
Mercantile
Street floor or basement used for sale 2.80 sqm
Upper floors used for sale 5.60 sqm
Floors not used for sale (office, storage, etc.) 9.30 sqm
Drinking establishments 1.40 sqm
Commercial kitchens 18.60 sqm
FIREWALL EXTENSIONS
Above roof 400mm
From outermost edges (walls) 600mm
Under eaves 300mm
EXITS
0-10 OL: 1 exit
10-499 OL: 2 exits
Number of exits required (based on occupant load)
500-999 OL: 3 exits
1000 or more OL: 4 exits
Minimum width of exits 1.10m (corridors)
Maximum travel distance to exit, no sprinkler 45.00m
Maximum travel distance to exit, with sprinkler 60.00m
Minimum width of exit door 900mm

Minimum height of exit door 2.00m


Change in floor level at doors 50mm
Maximum length of dead ends
Place of assembly
Educational
Healthcare
Detention/correctional
6.00m
Residential (hotels/dormitories)
Residential (apartment buildings)
Business
Business, with NFPA 13 sprinkler system
Industrial
ELEVATORS

In apartments or condomimiums 5
storeys or higher, at least 1
passenger elevator shall be kept on
24-hour constant service.
Various elevator requirements

Minimum 600mm-deep pit

Maximum 4 cars per hoistway


BP 344 RA 9514 BP 220

General: 2.00m
2.00m 2.00m
Bathroom/mezzanine: 1.80m
Main door: 0.80m
800mm 710mm Bedroom: 0.70m
Bathroom: 0.60m
1220mm
820-1060mm (900mm
preferred)

1.50m
1.50m
2.00m
0.75m

2.00m
2.00m for walkways 2.00m for means of egress

1.80m

10% of floor area

5% of floor area
2.00m
1.20m

Existing stairs: 205mm max.


250mm maximum
New stairs: 100-180mm
Existing stairs: 230mm min.
200mm minimum
Slanted nosing preferred New stairs: 280mm min.
over protruding nosing, Existing stairs: 915mm
provide 300mm-wide New stairs, 0-49 OL: 915mm
tactile strip at top and 600mm
New stairs, 50-1999 OL: 1120mm
bottom of stairs. New stairs, 2000 or more OL: 1420mm
2.00m 2.00m
3.66m 3.60m
760-865mm 800-1200mm

1 in 12 1 in 12
1 in 48
1.20m 1120mm
1.50m
6.00m (horizontal
760mm (vertical distance bet. landings)
distance bet. landings)
700mm and 900mm 760-865mm

1.20m

0.28 sqm
0.65 sqm
1.40 sqm

1.90 sqm
4.60 sqm
3.30 sqm

11.10 sqm
22.30sqm

18.60 sqm

2.80 sqm
5.60 sqm
9.30 sqm

300mm
300mm
300mm

0-500 OL: 2 exits 0-9 OL: 1 exit


501-999 OL: 3 exits
10 or more OL: 2 exits
1000 or more OL: 4 exits
915mm Additional note regarding exits: BP 220
specifically refers to Section 3.1007 of
PD 1185 (the old Fire Code) for the exit
requirements. This is included in BP
220 as Annex 1 on page 53.
800mm (for all doors)

2.00m (For all doors)


13mm

6.10m
6.00m
6.00m
Provide turnabout space 6.00m
within 3.50m of any dead
end 6.00m
end
Not allowed
6.00m
15.00m
15.50m

Inside dimensions of car: Required for healthcare occupancies two storeys


1.10m wide x 1.40m deep or higher.
Required for multi-family
dwellings and condominiums
6 storeys of higher. Follow
standards in NBC and BP 344.
Maximum travel distance
from building entrance: Provide at least one exit per elevator lobby.
30.00m
PD 957

Follow NBC

Follow NBC
For rowhouse: 300mm
For rowhouse: 300mm
For rowhouse: 300mm
Follow NBC
BP 220
Socialized Economic
RATIO BETWEEN SALEABLE AND NON-SALEABLE AREAS
Saleable
No fixed ratio
Non-saleable
MINIMUM AREA OF LOT
Single-detached 64.00 sqm 72.00 sqm
Duplex 48.00 sqm 54.00 sqm
28.00 sqm 36.00 sqm
Note: Minimum lot area for rowhouses classified as socialized was
Rowhouse
previously 32.00 sqm. However, this value was changed to 28.00 sqm as
per Board Resolution 824, Series of 2008 (check HLURB website).

MINIMUM LOT FRONTAGES


Single detached
Corner lot 8.00m
Regular lot 8.00m
Irregular lot 4.00m
Interior lot 3.00m
Duplex 6.00m
Rowhouse 3.50m 4.00m
MINIMUM FLOOR OF AREA OF SHELTER
Single and multi-family dwelling 18.00 sqm 22.00 sqm
Condominiums

Single-occupancy condominium
18.00 sqm 18.00 sqm

Family condominium
PARKS & PLAYGROUND ALLOCATION FOR SUBDIVISIONS
Required when Project is 1 hectare or bigger
0 - 150 lots/ha: 3.50%
151 - 160 lots/ha: 4.00%
161 - 175 lots/ha: 5.00%
Density : allocation
176 - 200 lots/ha: 6.00%
201 - 225 lots/ha: 7.00%
Above 225 lots/ha: 9.00%
Absolute minimum allotment 100.00 sqm
COMMUNITY FACILITIES ALLOCATION
Required when Project is 1 hectare or bigger
0 - 150 lots/ha: 1.00%
Density : allocation 151 - 225 lots/ha: 1.50%
Above 225 lots/ha: 2.00%
100 - 1,499 lots; Multipurpose center

1,500 - 1,999 lots; Add retail center, elementary school,


No. of saleable lots : facilities required
tricycle terminal

2,000 - 3,000 lots; Add high school


MINIMUM ROAD SIZES GIVEN PER ROAD TYPE
Interconnecting road 10.00m
Major road 8.00m
Collector road 8.00m
Minor road 6.50m
Motor court 6.00m
Pathwalk 3.00m
Alley 2.00m
MINIMUM LEVEL OF COMPLETION
Shell house, with doors and
Single-family dwelling Complete house
windows
PD 957
Medium cost Open market

Maximum 70%
Minimum 30%

100.00 sqm 120.00 sqm


80.00 sqm 96.00 sqm

50.00 sqm 60.00 sqm

12.00m
10.00m
6.00m
3.00m
8.00m
4.00m

30.00 sqm 42.00 sqm

18.00 sqm 18.00 sqm


12.00 sqm for students/ 12.00 sqm for students/
employees in highly employees in highly
urbanized areas urbanized areas
22.00 sqm 36.00 sqm

Project is 1 hectare or bigger


0 - 20 ha, 3.50%
21 - 25 ha, 4.00%
26 - 35 ha, 5.00%
36 - 50 ha, 6.00%
51 - 65 ha, 7.00%
Above 65 ha, 9.00%
100.00 sqm

Project is 1 hectare or bigger

None given None given

100 - 1,499 lots; Multipurpose center

1,500 - 1,999 lots; Add retail center, elementary school,


tricycle terminal

2,000 - 3,000 lots; Add high school

10.00m
10.00m
10.00m
8.00m
6.00m
3.00m
2.00m
Complete house