Water
Water
Water
AIR TO WATER
Residential
284 Split Type/Split DHW Integrated Type *New Super High Power series
286 Case Studies
Installation Limitations
288 Optional Parts
290 Specifications & Dimensions
AIR TO WATER
3 to 5 kWh
1 kWh of heat
Domestic Hot Water Electricity
Comfort heating
2 to 4 kWh
Ambient air
Floor Heating
278 279
PRODUCT LINEUP
AIR TO WATER
Home Heating
Air to Water Overview
Wide range lineup suited for regional characteristics, family structure, and
application. We provide various products to meet your needs from High
Power via heating-centered series to reasonably-priced compact series.
Solar Connection
Room
Heating
Height
DHW tank
Outdoor unit + DHW Tank
DHW tank (option) can be used to supply hot
Floor
Heating
Appearance-oriented water by connecting it to the system.
Domestic
Hot water Hydraulic unit compact outdoor unit
+ Boiler
Split type Comfort series
By combining existing boiler, powerful
For Comfort series, optimized flow temperature heating can be performed even at low
control is realized by DC inverter technology. outdoor temperature.
Swimming
*: Outdoor Unit: WOHA060LFCA/WOHA080LFCA *optional part necessary
NEW
Pool
Super High Power series
Single-phase: 16kW
3-phase: 15/17kW
Internet Remote control
system
AIR TO WATER
Web-server
Floor heating Radiator
(Option)
For Room heating & domestic Hydraulic indoor unit DHW tank
or
280 281
PRODUCT LINEUP
AIR TO WATER
Split
Injection Port Energy saving
Hydraulic Indoor Unit/ WSHG140DG / WSHG140DG /
It realizes the high condensing pump with constant Outdoor Unit WOHG112LHT WOHG140LCTA
temperature without overheating volume or pressure
discharge gas temperature by Linear adjustment function. High Power series
3 phase
Control Injection process during
compression. Therefore, the condensing
Hydraulic Indoor Unit/ WSHK160DG / WSHK160DG / WSHK160DG /
temperature rises up higher than normal Outdoor Unit WOHK112LCTA WOHK140LCTA WOHK160LCTA
circuit. A higher hot water temperature
is realized by controlling the injection Energy efficiency class Comfort series
WSHK170DJ9
amount according to the usage state. Linear Control
Injection Port
Hydraulic Indoor Unit/ WSHA050DG / WSHA100DG / WSHA100DG / WSHA100DG /
Outdoor Unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA
Optimized circuit = Stainless steel buffer tank
higher water temperature Accurate temperature control Super High Power
Heat exchange amount is 25% higher than series
by DC inverter technology Single phase
previous model. Energy saving performance
NEW
refrigerant flow
Heating cycle Hydraulic Indoor Unit/ WGHK170DJ9 / WGHK170DJ9 /
Outdoor Unit WOHK150LJL WOHK170LJL
Time
Hydraulic Indoor Unit/ WGHK160DG / WGHK160DG / WGHK160DG /
Outdoor Unit WOHK112LCTA WOHK140LCTA WOHK160LCTA
Outdoor unit
Comfort series
Easy Control
Hydraulic Indoor Unit Controller
4 Heating mode
AIR TO WATER
1. Automatic mode 3. Comfort mode
EHPA Quality Label SG-Ready Label
Comfort/Reduce mode switching Constant comfort Fujitsu General’s WATERSTAGE* have SG-Ready is a defined standard by BWP***, which makes
automatically according to time temperature obtained the EHPA Quality Label** by tests it possible that the device can be integrated into a smart
program according to the international Standards grid. Heat pumps, which are equipped with the SG-Ready
4. Protection mode EN14511 and EN17025. The EHPA Quality Label, can receive signals from the power grid (and
2. Reduce mode Stand-by mode with anti- Label** is a label that shows the end- e.g. also from PV systems) about the available (unused
Constant reduce temperature frost protection consumer a quality heat pump unit on the renewable) energy (from wind, sun & water). Fujitsu
market. General provides the SG-Ready compatibility to all new
*: only High Power 3phase Heat Pumps series.
**: Check the validity of label at www.ehpa.org/quality/quality-label/ ***BWP: the Federal German Heat Pump Association
282 283
PRODUCT LINEUP
AIR TO WATER
Integrated Type
temp. temp.
temperature is down to -20°C without using backup heaters. -20°C Water temp. Water temp.
-22°C
And it’s possible to supply 55°C at -22°C outdoor temperature 60°C 55°C
without backup heater.
Outdoor Outdoor
temp. temp.
-20°C Water temp.
-10°C Water temp.
60°C 55°C
Comfort series
Split Type High power series
* If you want to raise the hot water supply temperature, backup heaters can be used for auxiliary operation.
AIR TO WATER
NEW
NEW
Automatic heating curve control Radiator
Automatic temperature control
60 with heating curve
Automatic temperature regulation in accordance with heating curve
temperature (˚C)
(Depends on heating terminal and outdoor temperature)
Leaving water
50
Chosen heating curve zone
40
30
284 285
PRODUCT LINEUP
AIR TO WATER
Case Studies
2 emitter simultaneous heating (Individual control) 2 emitter simultaneous heating (Individual control) Single heating & Domestic Hot Water
Floor heating + Radiator Floor heating + Radiator Radiator + Domestic Hot Water
Pump
Pump
Outdoor Outdoor
unit Valve Pump unit
Pump
Radiator Valve
Radiator
Outdoor Radiator
Floor heating units Floor heating
Balancing vessel (Option)
Boiler connected to heating Boiler connected to heating 2 emitter simultaneous heating (Individual control) &
(Boiler + Heating) (Boiler + Heating) Domestic Hot Water
Radiator + Domestic Hot Water
Hydraulic Hot water Supply
indoor unit Hydraulic Hydraulic (e.g. for shower)
indoor units indoor unit
Boiler
Boiler
Installation Limitations
Hydraulic
Capacity Pipe diameter
indoor unit
Series range (Liquid/Gas) H1 (m) H2 (m) L (m)
AIR TO WATER
(kW) (mm)
5
350 mm 300 mm 6.35/12.70
Split type Hydraulic indoor unit mini Split DHW integrated type 6
Comfort +20 -20 5-30 Outdoor unit
Hydraulic indoor unit 8 6.35/15.88
• Hydraulic indoor unit is to be hang on
10 9.52/15.88
the wall • Floor stand L H2
11
1840 mm
286 287
PRODUCT LINEUP
AIR TO WATER
Optional Parts
Split Split DHW integrated type Split Split DHW integrated type
Super Super Super Super
High Power Comfort High Power Comfort High Power Comfort High Power Comfort
Product Name Model Name High Power High Power Product Name Model Name High Power High Power
1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 1Ø 3Ø 1Ø 3Ø 1Ø
16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10 16 15 17 11 14 11 14 16 5 6 8 10
Cascade Slave
UTW-KZDXE — — — — — — — — — — — — — — — Kit UTW-KCSXE — — — — — — — — — — — — — — — — — —
(incl. LPB Clip)
2nd Circuit Kit
UTW-KZDXJ — — — — — — — — — — — — — — — — — — — — — UTW-C74TXF*3
Remote Wired
Controller
UTW-KBSXD — — — — — — — — — — — — — — — UTW-C74HXF*3
Boiler
UTW-KBDXD — — — — — — — — — — — — — — — Wired UTW-C55XA
Connection Kit
Room
Thermostat
Outdoor Sensor
Balancing Vessel UTW-TEVXA UTW-MOSXD
Transmitter
UTW-KDWXD RF
DHW Kit —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 —*1 UTW-MRCXD
(External) Modules for BSB-Port
DHW Tank
Circulating Pump UTW-PHFXG — — — — — — — — MODBUS Clip UTW-KMBXJ —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7 —*7
Service Tool
Swimming
UTW-KSPXD (incl. OCI700 UTW-KSTXD *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5 *5
Pool Kit
Adapter)
AIR TO WATER
External
Connect Kit
Regulation
UTW-KREXD UTY-XWZXZ3 — — — — — — — — — — — — — — — — — —
Extension Kit
*1: DHW operation is possible without DHW Kit and DHW Tank. : Available — : Not Available
Low Noise *3: 19 Languages included, no separate Eastern European RC necessary. C74TXF: Built in Room Temperature sensor C74HXF: Built in Room temperature and Humidity sensor
UTW-KLNXE — — — — — — — —
Kit *4: Eastern European Language(English, Czech Republic, Slovakia, Poland, Turkey, Hungary, Russia, Slovenia, Greece, Serbia)
*5: UTW-KL1XD is required for the connection.
*6: UTW-KW1XD or UTW-KW4XD is required for the connection.
*7: Additional optional part necessary
Drain Pan UTW-KDPXA — — — — — — — — — — — — — — — — — —
288 289
PRODUCT LINEUP
AIR TO WATER
Dimensions
Dimensions
Outdoor Unit: Hydraulic Indoor Unit:
NEW
Single Phase: WOHG160LJL
NEW
Single Phase : WSHG160DJ6 Outdoor Unit: Hydraulic Indoor Unit:
3 Phase: WOHK150LJL/WOHK170LJL 3 Phase: WSHK170DJ9 Single Phase: WOHG112LHT/WOHG140LCTA 3 Phase: WOHK112LCTA/WOHK140LCTA/WOHK160LCTA Single Phase: WSHG140DG
3 Phase: WSHK160DG
688 650 650
(515.5)
450 450
400
400
Top view Top view Top view
40 480 12
900 77 31 330 12 900 31 330 12
832,8
800
1080
805
847
AIR TO WATER
471 81 457 81
97 98 97 98
1428
1290
1290
493 479
Heating return Heating flow Heating return Heating flow
Ø25.4 Ø25.4 Ø25.4 Ø25.4
21
21
Front view Side view Front view Side view Front view Side view
290 291
PRODUCT LINEUP
AIR TO WATER
for Split Type Comfort Series for Split DHW Integrated Type Super High Power Series
Dimensions
Dimensions
Outdoor Unit: Hydraulic Indoor Unit:
Outdoor Unit: Hydraulic Indoor Unit: NEW
Single Phase: WOHG160LJL
NEW
Single Phase: WGHG160DJ6
WOHA060LFCA/WOHA080LFCA WOHA100LFTA WSHA050DG/WSHA100DG 3 Phase: WOHK150LJL/WOHK170LJL 3 Phase: WGHK170DJ9
688 645
631
650 599
45.4
395
648 576
(515.5)
Drain port Ø20 450 43
352
320
400
AIR TO WATER
900 77 31 330 12
20 790 62 290
1854
1841
457 81
830
620
97 98
479 1428
Heating return Heating flow
20
Ø25.4 Ø25.4
21
103
698
Front view Side view Front view Side view
292 293
PRODUCT LINEUP
AIR TO WATER
for Split DHW Integrated Type High Power Series for Split DHW Integrated Type Comfort Series
Specifications Specifications
Hydraulic indoor unit WGHG140DG WGHG140DG WGHK160DG WGHK160DG WGHK160DG Hydraulic indoor unit WGHA050DG WGHA100DG WGHA100DG WGHA100DG
Model Name Model Name
Outdoor unit WOHG112LHT WOHG140LCTA WOHK112LCTA WOHK140LCTA WOHK160LCTA Outdoor unit WOHA060LFCA WOHA060LFCA WOHA080LFCA WOHA100LFTA
Capacity range 11 14 11 14 16 Capacity range 5 6 8 10
Heating capacity 10.80 13.50 10.80 13.50 15.17 Heating capacity 4.50 6.00 7.50 10.00
1 kW kW
7°C/35°C floor heating * Input power 2.54 3.23 2.51 3.20 3.70 7°C/35°C floor heating *1 Input power 0.996 1.41 1.84 2.49
COP 4.25 4.18 4.30 4.22 4.10 COP 4.52 4.27 4.08 4.02
Heating capacity 10.77 12.00 10.77 13.00 13.50 Heating capacity 4.50 4.95 5.65 7.70
kW kW
2°C/35°C floor heating *1 Input power 3.44 3.87 3.40 4.15 4.34 2°C/35°C floor heating *1 Input power 1.39 1.53 1.78 2.47
COP 3.13 3.10 3.17 3.13 3.11 COP 3.24 3.24 3.17 3.12
Heating capacity 10.38 11.54 10.38 12.20 13.50 Heating capacity 4.10 4.60 5.70 7.40
kW kW
-7°C/35°C floor heating*1 Input power 4.32 5.08 4.28 5.13 5.40 -7°C/35°C floor heating*1 Input power 1.47 1.74 2.23 2.97
COP 2.40 2.27 2.43 2.38 2.50 COP 2.79 2.64 2.56 2.49
Space heating characteristics*2 Space heating characteristics*2
Temperature application °C 55 35 55 35 55 35 55 35 55 35 Temperature application °C 55 35 55 35 55 35 55 35
Energy efficiency class A+ A++ A+ A+ A+ A++ A+ A++ A+ A+ Energy efficiency class A+ A++ A+ A++ A+ A++ A+ A++
Rated heat output(Prated) kW 9 11 11 13 9 11 11 13 13 14 Rated heat output(Prated) kW 4 4 5 5 6 7 8 8
Seasonal space heating energy efficiency(η S) % 112 151 113 148 112 154 117 150 117 149 Seasonal space heating energy efficiency(η S) % 115 169 115 169 118 156 113 155
Annual energy consumption kWh 6,704 6,062 8,041 6,824 6,669 5,930 7,803 6,738 9,062 7,408 Annual energy consumption kWh 3,026 2,160 3,180 2,505 3,886 3,375 5,415 4,415
Hydraulic indoor unit 46 46 46 46 46 Hydraulic indoor unit 46 46 46 46
Sound power level dB(A) Sound power level dB(A)
Outdoor unit 68 69 69 68 70 68 71 Outdoor unit 65 60 65 63 65 69 68 69
Domestic hot water characteristics*2 Domestic hot water characteristics*2
Load profile L Load profile L
Energy efficiency class A Energy efficiency class A+
Energy efficiency(η wh) % 88 Energy efficiency(ηwh) % 120
Annual electricity consumption kWh 1166 Annual electricity consumption kWh 880
Hydraulic indoor unit Specification Hydraulic indoor unit Specification
Power source Single-phase 230 V 50 Hz 3-phase, 400 V 50 Hz Power source Single-phase 230 V 50 Hz
Dimensions H×W×D mm 1,840× 648 × 698 Dimensions H×W×D mm 1,840× 648 × 698
Weight (Net) kg 152 Weight (Net) kg 152
Water circulation L/min 19.5/39.0 24.4/28.7 19.5/39.0 24.4/48.7 27.4/54.8 Water circulation L/min 8.1/16.2 10.8/21.7 13.5/27.1 18.1/36.1
DHW capacity L 190 DHW capacity L 190
Hot water heater capacity kW 1.5 Hot water heater capacity kW 1.5
Expansion vessel capacity L 12 Expansion vessel capacity L 12
Leaving water temperature range Max °C 60 Leaving water temperature range Max °C 55
Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4 Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4
Hot water pipe connection diameter mm Ø 19.05 Hot water pipe connection diameter mm Ø 19.05
Outdoor unit specification Outdoor unit specification
Power source Single-phase 230 V 50 Hz 3-phase, 400 V 50 Hz Power source Single-phase 230 V 50 Hz
Current Max A 22.0 25.0 9.0 9.5 10.5 Current Max A 12.5 17.5 18.5
Dimensions H × W × D mm 1,290 × 900 ×330 Dimensions H × W × D mm 620 × 790 ×290 830 × 900 ×330
Weight (Net) kg 92 99 Weight (Net) kg 41 42 60
Type (Global Warming Potential) R410A (2,088) Type (Global Warming Potential) R410A (2,088)
Refrigerant Refrigerant
Charge kg 2.50 Charge kg 1.10 1.40 1.80
Additional refrigerant charge amount g/m 50 Additional refrigerant charge amount g/m 25 40
Liquid Ø 9.52 Liquid Ø 6.35 Ø 9.52
Diameter mm Diameter mm
Gas Ø 15.88 Gas Ø 12.70 Ø 15.88
Connection pipe Length Min/Max m 5/20 Connection pipe Length Min/Max m 5/30
Length(Pre-charge) m 15 Length(Pre-charge) m 15
Height difference Max m 15 Height difference Max m 20
Operation range Heating °C -25 to 35 Operation range Heating °C -20 to 35
*1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of *1:The values of heating capacity/input power/COP are based on measurement of EN14511 standard. Usage environment, such as operation of
the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and
these values. these values.
*2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html *2:All information of ErP can be available for downloaded from https://www.fujitsu-general.com/global/support/downloads/search/index.html
Dimensions Dimensions
Outdoor Unit: Hydraulic Indoor Unit: Outdoor Unit: Hydraulic Indoor Unit:
Single Phase: WOHG112LHT/WOHG140LCTA 3 Phase: WOHK112LCTA/WOHK140LCTA/WOHK160LCTA Single Phase: WGHG140DG WOHA060LFCA/WOHA080LFCA WOHA100LFTA WGHA050DG/WGHA100DG
3 Phase: WGHK160DG
650 650 644 644
630 630
599 650 599
45.4
648 576 395 648 576
43 Drain port Ø20 43
400
400
352
320
400
Top view Top view
540 125
900 77 31 330 12 900 31 330 12 Top view Top view
AIR TO WATER
900 77 31 330 12
20 790 62 290
1850
1850
1840
1840
830
620
1290
1290
20
21
Side view Front view Side view
Front view Side view
21
21
Front view Side view Front view Side view Front view Side view Front view Side view
294 295