Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Catalog Chandler Engineering - ETA.0215

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Model 292B Portable Natural Gas Chromatograph

The production and custody transfer of natural gas requires accurate measurement of the composition of the gas.
Many contractual requirements define the desired composition, heating value and relative density of the gas being sold
or transported. Portable gas analysis of the critical components in natural gas ensures reliable results when installation of
stationary analyzers is impractical or costly.

The AMETEK Model 292B natural gas chromatograph is designed as a truly 'portable' analyzer. An integrated sample
inlet manifold allows for single connections of sample and drive (carrier) gases, allowing for flexible installation either as
a stand-alone analyzer, or integrated into a mobile platform such as a truck or other vehicle.

Chandler Dew Point Testers


BUREAU OF MINES-TYPE DEW POINT TESTER FROM AMETEK

The Chandler Bureau of Mines Dew Point Tester is a primary instrument used to measure the dew point temperature
of any gas. It is rugged, portable and can provide very repeatable results. Because of its primary nature, the standard
dew point tester requires no calibration. Consequently, it is frequently used to verify results of electronic instruments.

The Chandler Dew Point Tester, which meets ASTM D1142 and traceable to NIST, is a chilled mirror device that
operates by achieving the conditions required by the definition of dew point. When a gas is cooled out of contact with
liquid water, the humidity or water content remains constant, but the percentage of saturation increases until it reaches
100% and moisture begins to condense. The temperature at this point is known as the dew point or frost point.

Ranarex™ Gas Gravitometer


Ranarex Gravitometer measures the specific gravity of gases as compared to air. For many industrial process gases
there is a definite connection between the analysis of the gas mixture and its specific gravity. When the specific gravity is
involved in the analysis of the total mixture, or when the instruments are used with orifice metering in gas volume, they
are graduated in specific gravity. When the gravimetric principle can be applied, Ranarex gravitometer excells over more
complex and costly analyzers in total performance.

Chandler UGC Vibrating Densitometer


For more than 30 years, the Chandler Densitometer has been used by major pipelines and other industries. It was
developed primarily for extremely accurate fluid metering (custody transfer), plus many other applications, such as
pipeline interface detection, blending, process control, etc. The frequency output of the Chandler Vibrating Densitometer
is compatible with most flow computers.

For detailed information of each model, please refer to the product specification sheets.

33
Model 292B Portable Natural Gas Chanscope II Bureau of Mines Dew Point Tester
Chromatograph
Principle TCD Chilled mirror

Components C1~C5, C6+ Moisture

Range 0-2000 BTU/scf -129°C~ambient temperature

Accuracy ±0.05% ±0.1°C~±1°C (depend on ranges)

Sensitivity ±0.05% 0.1°C

Repeatability ±0.05% or 0.5BTU/1000BTU —


Limit of C2/C3/C4: 0.025%, varies with -129°C (depends on cooling
detection different component medium)
Measuring 12 Minutes Depends on final dew point and
cycle cooling rate
Analog output 0-10 VDC, 4-20mA (option) —

Communication RS-232C Modbus —


Sample gas 49 kPa-24.1 mPa 0-34.6 mPa
pressure
Flow rate 100-1300 mL/Minute 2.36 L/Minute
Power 115/230 VAC ±10%, 50/60 Hz Battery-powered with 115 VAC or
230 VAC charger (optional)
Operation -25~55°C -20~50°C
temperature
Explosion proof area Class 1, Division 2, Group C & D —

Enclosure NEMA 4 —
Installation Portable Portable
Weight 17 kg 11 kg
Dimension 280 × 267 × 457 200 × 355 × 178 (Portable case)
H×W×D (mm)
Main • Natural gas • Natural gas
applications • Sour gas
• Industrial gases
• Heat Treating Furnaces
Features Portable; Compliance with industry Portable; Meets ASTM D1142;
standards: GPA, ATMS, ISO, AGA; RTD traceable to NIST; Easy to maintain and use
Column can be used more than 10 years

34
Model Ranarex Gas UGC Vibrating
Gravitometer Densitometer
Principle Torque created by gases in Vibrating densitometer
opposite direction
Components Gas gravitometer Liquid density
Range Portable: 0.52-1.03/0.97-1.90 0.3 - 1.6 g/mL

Accuracy ±0.5% of real value ±0.0002 g/mL (0.3~0.5 g/mL),


depends on ranges
±0.00001 g/mL (0.3~1.0 g/mL),
Repeatability —
depends on ranges
Limit of detection — 0.3 g/mL

Analog output — Frequency: 1kHz~2kHz

Flow rate 4.7-9.5 L/Minute 5.7 L/Minute

Sample gas pressure <140 kPag <22.4 mPa

Operation temperature -18~54°C -40~85°C

Power 115 VAC, 60 Hz or 230 VAC, 50 Hz 24 VDC ±8 VDC @ 35mA

Explosion proof area GP Only Class 1, Division 1, Group C & D


Enclosure — NEMA 4, Optional NEMA 4X

Dimension
535 × 375 × 267 —
H×W×D (mm)
Weight Portable: 23 kg 11 kg
Main applications • Oil Refining • Pipeline interface detection
• Natural Gas Measurement • Blending
• Gas Utilities • Process control
• Chemical Processing
• Heat Treating Metals
• Combustion Analysis
• Sewage Treatment
Features Portable, Accurate, Continuous on-line density
Sensitive, Fast Response; measurement; Provides input for
Durable, corrosion-resistant mass flow calculations; Excellent
materials. Outer case protects repeatability and long-term stability; Model 278 CSA
against dust, humidity and shock. approved

35

You might also like