6.

General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0254
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


UDN Customized Bracket for optional Lock for the cassette The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Bezel Example
FL-0254 AA0000
ENCLOSURE: FL Bill Validator Software Part Number
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH 1. Assembly FL-0254 contents

OPTIONAL ACCESSORIES AND DOCUMENTS: Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01 600 Bill; UDN Customized Lock Bracket;
Housing FLH-0812
Cassette switch; 12pin JAE
Power
FLP-9028 24V DC, RS-232, Coated PCB, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-9016
Head Coated PCBs
Sense FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs; Coated PCB
Click
Bezel, Handled Bill width 70 mm,
Bezel FLB-9076
Coated PCB

CashCode Company Inc.


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2005, CashCode Co. Inc PT# UG- FL-0254_A 04/05


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 GND 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
VALIDATING HEAD AS SHOWN.
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved

You might also like