Rosemount Inc. 1495 - Standard Orifice ISO 5167 (2003) Calculation Data Sheet
Rosemount Inc. 1495 - Standard Orifice ISO 5167 (2003) Calculation Data Sheet
Rosemount Inc. 1495 - Standard Orifice ISO 5167 (2003) Calculation Data Sheet
Flow Rates:
Minimum: 9.33 m3/hr
Normal: 13.20 m3/hr
Maximum: 16.16 m3/hr
Full Scale: 18.66 m3/hr
CALCULATED DATA (Calculation Performed at Normal Conditions.)
Plate Thickness:
Pipe ID (thermally corrected) 62.516 mm Bore Size (thermally corrected) 45.457 mm
GUIDELINES
Primary Element Min Limit of Use 1.69 m3/hr Min Recommended Pipe Reynolds: 5619.0
Max. Allow. Pressure @ Temp: 11.0 bar-a 80.40 K Recommended Min DP: 6.339 mmH2O@4C
Design Pressure/Temperature: 1.913 bar-a 80.400 K Max. Allow. Temp.: 1088.706 K
WARNINGS
NOTES
This report is provided according to the terms and conditions of the Instrument Toolkit(TM) End-Use Customer License Agreement.
Version: 3.0 (Build213A) Printed On: 17-Jun-19
Orifice Plate Sheet of
Unit Req. BY