1. Maintenance Software
The maintenance software of JCY-1700 is a PC-based application. It serves the purpose of configuring and inspecting
the product at the factory. On board the ship, it helps users to install the JCY-1700, change its settings, do its
operational checkup, and to find the causes of malfunctions, if any.
● The latest Maintenance Software (Ver 2.0.0B) is applicable to the maintenance of both the
JCY-1700 and JCY-1700S. The VDR model to maintain is chosen at startup of Maintenance
Software.
● When the software of RCU and DAU is updated to “2.0.0”, some added functions are able to be
operated. The following added functions cannot be operated in case of maintaining the RCU
and DAU installed old software.
• RCU setup: Capsule setting function
• DAU setup: Serial screen → Watch function
Added items (AIS,DCNT+A/D) of TYPE function
The software of RCU and DAU is updated for adapting to S-VDR and additional option units.
1) Software name:
JCY1700-maint.exe
5) OS:
Windows 2000, Windows Xp
* This software does not run on the Windows 95 / 98 / Me.
6) PC:
Minimum requirements for a lap top PC:
CPU: Pentium III 1GHz or more
When the PC of low specification is used, do not use monitoring functions (NMEA,
Audio, Radar) simultaneously.
PCMCIA card slot: PC card as a data backup medium of VDR
Communication I/F: Ethernet (10/100Mbps)
Screen resolution : 1024×768 (XGA)
7) Personal Firewall
In using the personal computer which enables the personal firewall function, use the maintenance software after
disabling it.
● Personal Firewall
A personal firewall is a filtering facility of LAN communication link attached to OS (Windows Xp) and the software for a virus
countermeasure.
● When a personal firewall is enable.
The VDR becomes impossible to communicate to the maintenaunce PC by a firewall function.
3. Maintenance software The outline of each function is explained according to the menu - - - -
functional list composition of maintenance software.
4. Starting and quitting of The operation method for starting and quitting of maintenance 1 █ 1 █
maintenance software software are explained.
5. Setup of RCU system The operational method of a system setup for the RCU is 2 █ 2 █
configuration information explained.
6. Setup of DAU system The operational method of a system setup for the DAU is 3 █ 3 █
configuration information explained.
7. System operation check The operational method for checking the VDR system status is 5 █ 4 █
explained.
Checks that the system setup is right.
Checks that each unit is operating normally.
Checks that data is collected.
8. Record data check The operational method for checking the record data of the VDR 6 █ 5 █
is explained.
Checks record data in the HVR.
Checks record data on the PC card.
9. Setup of the factory shipping The operational method of setup required only at the factory is 4 █ - ▲
explained.
However, when changes have occurred differing from the
contents of installation drawings at the time of shipment,
resetting the change operation is required at the time of
installation.
10. Troubleshooting utility The operational method of checking the system error is - ▼ - ▼
explained.
11. Program version upgrade The operational method for upgrading the program of the VDR - ▼ - ▼
is explained.
12. Installation The operational method for installing the maintenance software - - - -
is explained.
3. Functions
Menu Trees
When the JCY-1700S (S-VDR) is chosen to maintain, functions with “*” mark are deleted from menu of the Maintenance Software.
Because functions with “*” mark are unnecessary to maintain the JCY-1700S (S-VDR).
4.1 Procedures
4.1.1 Starting
1) Double-click the “Maintenance Software” icon.
2) The maintenance software will starts up, and it brings up the Log in Window.
Log in window
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.1.2 Enter the Name of the Person in charge, Company Name, and Password. “Register Information”
1) Registrant information
Enter the information of the registrant, which will be recorded onto VDR.
• Name of the person in charge
• Name of the company
2) Password
As you enter the password, the field appears as a string of “*”.
The password for a service engineer, who is in charge of installation, is “JRCVDR” (see 4.4 for more details).
Many of recent lap top PCs are equipped with not only wired LAN but with wireless LAN as well. Such a PC has
two Ethernet adapters. Select the adapter for the wired LAN.
1) [Add IP]
Click the [Add IP] button and register the IP address for the VDR.
The subnet mask “255.255.255.0” is set automatically.
Follow the procedures for quitting maintenance and delete the newly registered IP address when quitting the maintenance
operation. Even though you may forget to delete it, it will be deleted when the PC is rebooted.
2) [Cancel] button
Maintenance software will be started without entering registrant information and a password, the functions
which can be used are restricted. Although setting functions cannot be used, displaying functions can be used.
When the Maintenance software is started up without connection to the RCU, Click the [Cancel] button.
( In case of setup to the DAU and other functions)
1) Click the HVR in the SETUP menu to start the HVR setup WEB.
If you quit the main window of the maintenance software without quitting the real-time monitor function, the VDR continues to
send the recording data to the maintenance PC in real-time. Be sure to quit the real-time function before closing the main
window.
If you close the main window first by mistake, reboot RCU and DAU, which cancels the real-time output already ordered from
the maintenance PC.
4.4 Password
There are two kinds of passwords: one is used during the inspection at the time of factory shipment, and the other
for maintenance or installation on board the ship.
4.4.1 Password
1) Password for installation onboard : JRCVDR
2) Password for inspection at the factory : ******* (It’s not written in this manual.)
Some maintenance functions are restricted when the password for a service engineer is used, because there are
some settings that should not be changed on site. This avoids confusion caused by seeing unnecessary displays. If
you find it necessary to change some of these settings, contact the person in charge of the product at the factory.
This is made for cases where the password for shop inspections is entered.
The login conditions can be changed without quitting the maintenance software.
• To change the registrant information
• To switch the password from maintenance to that for inspections at the factory
• To change the model to maintain ( JCY-1700/JCY-1700S )
The item that requires an input at the time of factory and onboard is shown in the following table. Set up all the
items needed.
● R::: Input restrictions with a password: Blank = With no restriction
■ = The setup is possible only with a factory setting password.
● F::: Factory: ▼ = The setup is required.
● O::: Onboard: ▲ = The change setup may be carried out at the time of installation.
No. Screen Category Item R F O Note
1 Identification Ship information Ship’s name ▼
2 IMO number. ▼
3 VDR information Type Approval number ■ ▼
4 Shipment order ■ ▼ Input the order of 5000 and number of
equipment.
5 System Microphone setup. Connecting ▼
6 Installation position ▼ Input a Text.
7 Microphone unit Type ■ ▼
8 Manufacturer ■ ▼
9 VHF setup Connecting ▼
10 VHF transceiver Type ▼
11 Manufacturer ▼
12 Serial Number ▼
13 GPS Connection form ■ ▼ One-set connection / Two-set connection
(Main / Sub)
14 Unit name ▼ Input DGPS as text input.
15 Type ▼
16 Manufacturer ▼
17 Antenna installation ▼
position
18 Connection equipment ■ ▼ ▲ Main/Sub judging signal selection by the dry
selection contact signal.
19 Radar Connection form ■ ▼ One-set connection / Two-set connection
(Main / Sub)
20 Type ▼
21 Manufacturer ▼
22 Serial Number ▼
23 Record interval ■ It is not necessary to change the setting.
(15seconds).
24 Record time adjustment ■ It is not necessary to change the setting.
(0).
25 Connection equipment ■ ▼ ▲ Main/Sub judging signal selection by the dry
selection contact signal
26 Ethernet All items ■ It is not necessary to change the setting.
27 Configuration System All items ■ ▼ Number change of connection of DAU.
configuration
28 A real-time All items ■ A setup is required only at the time of an
monitor option system.
29 Serial Reception (GPS) ■ It is not necessary to change the setting.
5.2 Procedure
File menu
Tab
Unless the standard setting values are entered, the [Set], [All set], [Reboot] buttons are not available.
3) Selecting tab
Click the tab of the items which you wish to set.
4) Editing
Change setting values.
5) Setting
Click the [SET] button to transmit the updated setting values to the RCU.
5.3.1
5.3.2
5.3.3
5.3.4
5.3.7
5.3.5
5.3.6
5.3.1 [ Receive ]
Clicking this button, the maintenance software receives configuration data from the RCU.
5.3.2 [ Set ]
Clicking this button transmits the setting values on this screen to the RCU.
[ SET ] button registers only the data on the screen currently displayed onto the RCU. If editing is completed, click the [SET]
button for every screen and be sure it transmits.
5.3.3 [ Reboot ]
Be sure to click this button after completing editing or registering the setting values.
The updated setting values become effective only after the [Reboot] button is clicked.
• Clicking on this button saves the setting values onto RCU as well as the HVR.
• Clicking on this button makes RCU run on the updated setting values by rebooting it.
An “Initial error” occurs if you start the RCU by using the main power SW without clicking the [Reboot] button.
When the “Initial error” appears, the operation with [FUNC+RESTART] of the clause 10.1.2 can reset the error.
( Button operation on the internal operation panel of RCU is also possible. )
5.3.5 [ Default ]
Initializes the setting value of the screen currently displayed.
[ Default ] and [ All Default ] button appears, only when it’s logged in with the password for inspections.
These are used when creating a system configuration information file in the state where it does not connect with RCU.
5.3.7 [ Close ]
This button terminates the setting of the RCU configurations.
1) Save
Click “Save” in the File menu. The dialog for inputting the name of saved file will be displayed.
2) Open
Click “Open” in the File menu. The dialog for specifying an object file will be displayed.
5.4 Identification
How to set the identification information of the VDR (RCU) are explained in this section.
( ■ ) mark is placed in the field to indicate an invalid input when logged in with the password for installation.
5.4.1 5.4.2 ( ■ )
5.4.3
5.4.4
When you login and click the [Receive] button, the information registered on the VDR is displayed.
Registrant information is updated when [Set] button is clicked on any screen.
5.5 System
How to set the VDR (RCU) configurations are explained in this section.
( ■ ) mark is placed in the field to indicate an invalid input when logged in with the password for installation.
5.5.1
5.5.1.1
( ■ ) 5.5.1.2 5.5.1.3 ( ■ )
5.5.2
5.5.2.2
5.5.2.1
5.5.3 5.5.3.1 ( ■ )
5.5.3.2 5.5.3.3
5.5.3.4
( ■ ) 5.5.3.5
5.5.4 5.5.4.1 ( ■ )
5.5.4.3 ( ■ )
5.5.4.2 5.5.4.4 ( ■ )
5.5.4.5
5.5.4.6 ( ■ )
5.5.1 Microphone
How to configure microphone ports are explained.
2) Installed:
Type in the position of the microphone using less than 31 characters.
The entry fields in “VHF transceiver unit” becomes “unable” if “Not-connect” is selected.
DAU SWITCH
NMEA Main GPS
Serial Input
Port
The VDR standard is required to record the type of equipment that is entered for ship’s position and time correction.
Therefore the equipment type name, DGPS, is entered here, too.
Para. 5.5.3.2 through 5.5.3.4 is for both the main and sub GPS’s.
Only when “Main/Sub GPS” is selected in para. 5.5.3.1, does the entry field of the sub GPS become “able.”
→ Enter the entry field of the sub GPS.
If the GPS selection port is not connected, the state of the dry contact signal is “Open.”
By default, the state of dry contact signal “Open” indicates that the Main GPS is selected.
5.5.4 RADAR
Entering Radar information.
RCU SWITCH
RGB Main Radar
FGB
Sub Radar
Input Port
5.5.4.4 Adjusting ( ■ )
The correction time value for adjusting the recording time of RADAR image can be set in milliseconds. By
default, it is set as 0ms, and there is no need to change it.
The recording time is not equal to the time which captures the RADAR image. There is a gap between the two timings.
The correction time value is used to narrow this gap. But actually, the gap is negligible, and therefore there is no need to
change this setting value.
Para. 5.5.4.2 through 5.5.4.4 is for both the main and sub RADAR devices.
Only when “Main/Sub RADAR” is selected in para. 5.5.4.1, does the entry field of the sub RADAR become “able.”
→ Enter the entry field of the sub RADAR.
If RADAR selection port is not connected, the state of the dry contact signal is “Open.
“ By default, the state of dry contact signal “Open” indicates that the Main RADAR is selected.
5.6 Ethernet
How to set the parameters of Ethernet network connected to the RCU is explained.
If the password for installation is used to login, this screen does not appear.
Therefore, the ( ■ ) marks are placed in all fields.
The setting change for “Ethernet” is required only when building an option system. Do not change the setting when the
JCY-1700 is shipped with standard composition. If the IP address is forgotten it will to be impossible to use the maintenance
by the LAN connection.
( ■ ) 5.6.1
5.6.3 (■)
( ■ ) 5.6.2
( ■ ) 5.6.4
( ■ ) 5.6.7
( ■ ) 5.6.8
5.6.2 System ( ■ )
Set the common parameters of the Ethernet.
1) Subnet mask
255.255.255.0
2) Default gateway
192.168.110.100
This is needed when UDP signals from VDR are transmitted to another LAN network via a router.
5.6.3 Capsule ( ■ )
Set information of HVR.
1) IP address
192.168.110.2
2) Port No.
5000
5.6.4 RCU ( ■ )
Set information of RCU.
1) IP address
192.168.110.3
2) Port No.
y For DAU: 5000
y For Option/Maintenance PC: 6000
5.6.5 DAU ( ■ )
Set parameter for Ethernet of the DAU.
1) Standard IP address
192.168.110.100
2) Port No.
y For RCU: 5000
The actual IP addresses of DAU1 and DAU2 are obtained by adding the unit number to the standard IP address as below.
y DAU1: 192.168.110.101 y DAU2: 192.168.110.102
5.6.6 FGB ( ■ )
Set parameter the Ethernet of the FGB.
1) Standard IP address
192.168.110.150
2) Port No.
y For browser: 80
5.6.7 Option/Maintenance PC ( ■ )
Set the IP address of the PC that is connected to the VDR.
1) Option PC
IP address of the PC as a real-time monitor (option)
192.168.110.200
2) Maintenance PC
IP address of the maintenance PC
192.168.110.200
3) Port No.
The port number to which real-time monitor signals are transmitted
y Audio data: 50002
y Event data: 50003
y Reference (image data are transmitted to FGB): 50001
Notice that when an optional PC is not used, the IP address of the maintenance PC (192.168.110.200) is used as
the default setting. When any optional system is to be setup, its IP address needs to be renewed.
The IP address indicates where real-time signals (UDP/IP) are transmitted.
5.6.8 IT Network ( ■ )
Set the connection of the FTP to the maintenance PC server on the ship (under development).
1) IP address
192.168.110.160
2) FTP Port No.
21
3) User name
4) Password
Since it has only registered as provisional specification, it is not the last specification.
In using it, it sets up at the time of factory shipments.
5.7 Configuration
This screen is not displayed when the password for maintenance is used to login.
Therefore, the ( ■ ) marks are placed in all fields.
( ■ ) 5.7.3
5.7.4 (■)
( ■ ) 5.7.5
( ■ ) 5.7.6
( ■ ) 5.7.7
1) Standard Components
The following components are standard and marked with a [9].
y Capsule y DAU1 y FGB y ARB
2) DAU2
When DAU2 is added to the system, mark with a [9].
3) Capsule type
As the capsule for JCY-1700 is a “NDH-288B”, “288B” is set as the default setting value.
An option “288A” is for the old type of capsule”NDH-288A”. The difference between “288A” and “288B” is in their memory
capacities. The setting needs to be changed if it is connected to NDH-288A. If “288A” is selected for JCY-1700, event is not
recorded in the capsule.
Set up when you confirm a real-time data output as a system option function.
Effective (mark with a [9]) / non-effect is set up for every signal to output.
- Reference -
About Real Time Monitor as the maintenance function
The data output is terminated when the power supply is restart. The data can be output to the IP address of the Maintenance
PC.
2) Adjusting
Time correction can be fine tuned in ms.
5.7.5 ARB ( ■ )
The operation parameters of the ARB can be updated. However, there is no need to do so.
5.7.6 IT Network ( ■ )
Set up of I/F specification for the onboard failure diagnostic system is under development.
Since it has only registered as a provisional specification, it is not the last specification.
In using it, it sets up at the time of factory shipments.
1) Ports 1-3
For each port, select the use from the following options.
y Input port of switch signals when two GPS’s or two RADAR devices are used.
y Input port of general dry contact signals
→ If the number of dry contact inputs are 3 or less, optional unit for dry contact signals (i.e., digital signal
converter NCT-57/63) is not needed.
2) Header
Enter the header of output data sentences when the port is used as an input port of dry contact signals.
4) Sentence cycle
Set the output conditions when the port is used as an input port of dry contact signals.
Set the time interval in the second unit at which data are transmitted even though there is no change in the
incoming dry contact signals.
The Dry Contact updating of the settings is only viable when the Dry Contact is selected.
5.8 Capsule
This function is added with software update (Ver. 2.0.0) of the RCU.
The Maintenance software does not display this screen in case of maintaining to the RCU installed old software.
This screen is not displayed when the password for maintenance is entered to login.
The item that requires an input at the time of factory and onboard is shown in the following table. Set up all the
items needed.
When the JCY-1700S (S-VDR) is chosen to maintain, screens with “*” mark are deleted from DAU setup.
Because functions on screens with “*” mark are unnecessary to maintain the JCY-1700S (S-VDR).
6.2 Procedure
1) Starting up
Select [DAU] in the SETUP menu, and then select either DAU1 or DAU2.
2) Procedure
Basically the same as what is instructed in “5.2 Procedures” of “5. Setup of RCU”.
Refer to “5.2 Procedure”.
Basically the same as what is instructed in para.“5.3 Common Buttons” of “5. Setup of RCU”. Refer to para.“5.3
Common Buttons”.
The updating of the other settings, however, becomes effective only after the [Reboot] button is clicked.
This is because of understanding that once the setting of the filter of NMEA sentence is updated, it should be made effective as soon
as possible.
6.4 Identification
( ■ ) mark is used as a default of an input when logged in with the password for installation.
6.4.1
( ■ ) 6.4.2
6.4.3
1) Initial
The name of the person in charge, company name, and the date & time of registration (UTC) are automatically
registered if you login using the password used for inspections at the factory when update the DAU
configurations.
2) Amendment
The name of the person in charge, company name, and the date & time of registration (UTC) are automatically
registered if you login using the password used for maintenance on site when update the DAU configurations.
When you login and click the [Receive] button, the information registered on the VDR is displayed. Select this tab and
click either the [Set] button or the [Reboot] button, only then is the registrant information is updated.
6.5 System
( ■ ) mark used as a default of an input when logged in with the password for installation.
( ■ ) 6.5.1
1) Correction interval ( ■ )
The interval of time at which the time of the VDR is corrected automatically can be set. By default, it is set as
12 hours, and it is unnecessary to change this setting.
2) Adjusting ( ■ )
The correct time value can be set to adjust in milliseconds. By default, it is set as 0ms, and there is no need to
change it.
The correct time value is intended for use in the cancellation of the time lag that may be caused by the delay of time
correction. However, the time lag is negligible and therefore there is no need to change this setting.
3) Host unit ( ■ )
Set the DAU connected to the GPS. Select DAU1 or DAU2 from the pull-down menu.
→ By default, it is DAU1 and there is no need to change this.
4) Input port ( ■ )
Set the CH number for the serial port connected to GPS.
6.6 Serial
6.6.2
6.6.1 6.6.6
6.6.3
6.6.3.1 6.6.3.2
6.6.3.3 6.6.3.4
6.6.4
6.6.5
6.6.1 Channel
Select the DAU serial port channel from the pull-down menu (CH01-CH16).
6.6.2 Enable
For each serial port of the specified CH, select “Enable” or “Disable”.
Mark with a [9] if a sensor is connected to the designated CH.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Once the serial port is set to “enable” [9], all the entry fields of the display become “enable.”
6.6.3.1 Type
Select the type of receiving sentences.
No. Type Connector Selectable CH Remark
1 NMEA General sensors CH01-CH16 NMEA
2 NSK NSK unit (option) CH01-CH16 NCT-27B
3 NAV-I/F NAV-I/F unit (option) CH12 NCT-52A
4 DRY-CNT Digital signal converter unit (option) CH13、CH14 NCT-57/NCT-63
5 A/D Equipment with built-in DAU, Analog input unit CH15、CH16 NCT-58 (A/D built-in)
NQA-4091A
6 DCNT+A/D Equipment with built-in DSC CH13、CH14 NCT-57/NCT-63
*1 *2 (Addition of the optional A/D converter board) (A/D built-in)
7 AIS *1 AIS unit CH01-CH16 NMEA
*1 These types will be selectable with the latest software (Ver. 2.0.0) update of the DAU.
*2 Select the “DCNT+A/D” when the optional A/D converter board is built in the DSC.
Channels that an option unit can be connected to are limited. For only these channels, the sentence type of option unit
can be selected.
Once the type is selected, this parameter is automatically set by default. There is no need to change this value.
Once the type is selected, this parameter is automatically set by default. There is no need to change this value.
1) Header
Enter the header character.
“$” is entered in case of connecting to the general sensor units.
In case of connecting to the AIS, enter “!” as the header character. (DAU software: Ver. 2.0.0 or later)
When “!” is entered, the DAU receives the NMEA sentences with “$” and “!” as header.
2) Delimiter
Enter the delimiter in the form of codes. The delimiter is expressed as codes not as characters. “<CR><LF>“ can be
codified as “OD OA”.
1) Sentence ID
Set the sentence ID for filtering the sentence to be recorded.
y Type in 7 characters maximum, starting from the next to the header characters.
y Enter all the sentence IDs of the sentences to be recorded. A maximum of 12 IDs can be registered.
y The talker ID (2 characters) can be entered along with the sentence ID (3 characters).
y An uncertain character also can be entered using “?”.
y Enter as many characters as you like (up to 7 characters).
y At least, include the sentence ID (3 characters).
y Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK )
▫ GPZDA ▫ GPZDA?? ▫ ??ZDA ▫ ??ZDA??
As for JCY-1000, sentence ID are 3 characters and different in the way it is set. →Input only sentence ID (3 characters ).
2) Contents
Select the type of information obtained from the filtered sentences.
Recording items No. Character string displayed ID NMEA
Date and Time 01 Date and Time 001 ZDA
Ship's position 02 Ship's position 002 GGA
03 Local geodetic datum (DTM) 003 DTM
Ground/Water speed 04 Ground/Water speed 004 VBW
Ship's heading 05 Ship's heading 005 HDT
HDG
06 Water speed and heading 027 VHW
Depth 07 Depth 007 DPT
Rudder order and response 08 Rudder order ,manual 030 HTD
09 Rudder response ,manual 009 RSA
10 Rudder order ,automatic 011 HTC
11 Rudder response ,automatic 010 HTD
M/E RPM set order and response 12 M/E RPM set order ( CPP order ) 012 PRC
13 M/E RPM actual response ( CPP order ) 013 RPM
14 Telegraph order position 021 ETL
15 Thruster order 018 TRC
16 Thruster response 019 TRD
Main alarms 17 Main alarms (ALA) 008 ALA
and 18 Alarm information (ALR) 038 ALR
alarm of each units 19 Fire detection 017 FIR
( AIS and so on ) 20 Water level detection 020 WAT
Door status 21 Door status 032 DOR
Hull door status 22 Hull door status 014 DOR
Fire door status 23 Fire door status 015 DOR
Watertight door status 24 Watertight door status 016 DOR
Accelerations and Hull stress 25 Accelerations 022
26 Hull stress 023 HSS
Wind speed and direction 27 Wind speed and direction 024 MWV
Analog option 28 A/D convert data-1 (Option unit) 026 VRXDR
29 A/D convert data-2 (Option unit) 033 VRXDR
NAV-I/F option 30 NAV-I/F data (Option unit) 028 ANADATA
Dry contact option 31 Dry Contact data-1 (Option unit) 029 *****
32 Dry Contact data-2 (Option unit) 034 *****
Radar 33 Radar target 025 TTM
AIS 34 AIS VDO data 035 VDO
35 AIS VDM data 036 VDM
36 Status information (TXT) 037 TXT
Navigation 37 Heading steering command (CTS) 039 HSC
38 Rate of turn 040 ROT
Water current 39 Water current 041 VDR
Others 40 Other 999
This setting does not affect the overall operation of the VDR. However, be sure to set this value because this is going to be
important information when the recording data is played back.
This function is added with software update (Ver. 2.0.0) of the DAU.
The Maintenance software does not display this function in case of maintaining to the DAU installed old software.
When all NMEA sentences are set as “Disable”, the VDR will operate as follows:
• The VDR generates the error alarm of no NMEA sentences at the DAU start up. ( NG lamp lights up)
•The VDR clears the error alarm at receiving a NMEA sentences. (OK lamp lights up, NG lamp puts out the light)
• The VDR does not generate the error alarm again even if no NMEA sentences receve. (OK lamp continues lighting up)
This setting as “Disable” is recommended if a user can output a NMEA sentence easily.
Explain how to clear an error by outputting a NMEA sentence
6.6.6.1 1)
6.6.6.2
6.6.6.1 2)
Set up in order to record the right data even this setting does not affect the overall operation of the VDR. The setting values
need to be set to convert the output of the NAV-I/F into signals concerning the rudder angle and the wind direction.
6.7.1 6.7.4
6.7.3
6.7.2
6.7.4 6.7.5
6.7.4
6.7.1 Enable
Mark with a [9] if a sensor is connected to the specified CH.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
“Rudder” can be select in both CH1 and CH2 . However, since NCT-52A does not correspond to a twin rudder, even if it sets up,
it does not operate.
-- procedure --
-1 Select the setting CH.
-2 Setup ratio of the connect equipment.
-3 Click [NAV-I/F connect] button.
-4 Control the actual rudder, so that the rudder angle value is set to "00.0."
-5 Click [Initializing] button.
-6 Wait for 5 seconds until initial processing of a NAV-I/F unit (NCT-52A) is completed.
-7 Click [Keep rudder=0.0 and press]button.
-8 The rudder angle value displayed on the "Check value" field is recorded on VDR. Check whether a display
value on the “Check value” is right.
-9 Redo from procedure “-5” when it is not right.
-10 Click [Read]button, when checking the setting data to the NAV-I/F unit (NCT-52A).
-11 Click [NAV-I/F disconnect] button to quit when the setup is correctly set.
When an operation start is carried out with the [NAV-I/F connect] button, finally, click the [NAV-I/F disconnect] button to quit surely.
The button ([Set] etc) of the setting relation on the right side of a screen does not become effective if the [NAV-I/F disconnect] button
is not clicked to quit.
Restart the DAU when the quitting operation has not made.
The data of NAV-I/F is not recorded to VDR if the quitting operation is not made.
-- procedure --
-1 Select the setting CH.
-2 Set up the wind direction setting.
-3 Click [NAV-I/F connect]button.
-4 Control the anemoscope to stabilize the value of the wind direction.
-5 Click [Initializing] button.
-6 Wait for 5 seconds until initial processing of a NAV-I/F unit (NCT-52A) is completed.
-7 Enter the value of the wind direction which is displayed on the anemoscope.
-8 Click[SET]button.
-9 The value of the wind direction displayed on "Check value" field is recorded on VDR. Check whether a
display value on the “Check value” is right.
-10 Redo from procedure “-5 “ when it is not right.
-11 Click [Read]button, when checking the setting data to the NAV-I/F unit (NCT-52A).
-12 Click [NAV-I/F disconnect] button to quit when the setup is correctly set.
Since the analog signal input channels of CH3 and CH4 are not used, explanation is omitted.
6.8 Contact
(When the JCY-1700S is chosen to maintain, this screen does not be displayed.)
How to input the information for managing the dry contact signal is explained.
Although this setup does not affect operation of the VDR, please be sure to set it up in order to record the right data. These
setup value are used with playback software.
6.8.1 6.8.2
6.8.3
6.8.1 Select CH
Select the Serial CH (connect the DSC) of the DAU. Select CH13 and CH14 whichever is connected to the DSC.
"TYPE" setup (Setup at serial menu) of Selection CH Unless it is "DRY-CNT", the [File read] button does not become effective.
If [File read] button is not becoming effective, check a setup of a "Serial screen."
6.8.3 Sentence ID
Talker ID and Sentence ID which DSC generate sentence are displayed.
6.9 Analog
(When the JCY-1700S is chosen to maintain, this screen does not be displayed.)
How to set the connecting information of the analog signal output equipment is explained.
Input the parameter for converting an output value (%) into a real value(displayed).
6.9.1
6.9.2
6.9.3.2
6.9.3
6.9.3.1
6.9.3.3
6.9.3.4
6.9.3.5
6.9.1 Serial CH
Select the Serial CH of the DAU that is the object of setup (Connected AIU).
1) Select CH
Select CH from CH15 and CH16 whichever connects to the AIU (NQA-4091A).
If "TYPE" setup of Selection CH (setup in a Serial screen) is not "A/D", all items will be in an input prohibited state. When
displayed in the state of input prohibition, check a setup of a "Serial screen."
6.9.2 Calculate
Set up the coefficient of the formula which converts the output value (%) of the AIU into a real value(displayed)
with the following procedure.
-- procedure --
-1 Select the analog CH to set up.
-2 Input the minimum value of the analog signal output equipment (real value) into the “Equipment value”
field of “Low Point”.
-3 Input the A/D conversion value equivalent to an input value into a "Sentence Value" field.
-4 Click [ Set ] button of “Low Point”.
-5 Input the maximum value of the analog signal output equipment (real value) into the “Equipment value”
The manual input and a receiving input are possible for the "Sentence value" item of A/D conversion value(%).
When you click the [Receive] button, the A/D conversion value is set into the "Sentence value" field.
In the case of receiving, operation will be performed after operating as the measured value of object equipment (real value)
becomes maximum / the minimum value inputted into the "Equipment value" field.
Conversion formula
y=A1*10A2x+B1*10B2
6.9.3.1 Enable
Input the existence of the sensor equipment for connecting to each CH of the AIU.
In setting it as those with connection, please click and check the "Enable" check box.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Keep in mind that it does not receive the CH data which has not carried out by a valid setup.
6.10 Ethernet
How to set the parameters of Ethernet network connected to the DAU is explained.
If the password for installation is used to login, this screen does not appear.
Therefore, the ( ■ ) marks are put on all fields.
The setting change for “Ethernet” is required only when build an option system. Do not change the setting when the
JCY-1700 is shipped with standard composition. If the IP address is forgotten it will be impossible to use maintenance via
the LAN connection.
( ■ ) 6.10.1
( ■ ) 6.10.2
( ■ ) 6.10.3
( ■ ) 6.10.4
( ■ ) 6.10.5
The MAC address is a unique address assigned to the Ethernet communication adapter.
It is registered at the factory and should never be changed.
6.10.2 System ( ■ )
Set the common parameters of the Ethernet.
1) Subnet mask
255.255.255.0
2) Default gateway
192.168.110.100
This is needed when the UDP signals from the VDR are transmitted to another LAN network via a router.
6.10.3 RCU ( ■ )
Set information of RCU.
1) IP address
192.168.110.3
2) Port No.
y For DAU: 5000
y For receiving of time correction signals: 7000
6.10.4 DAU ( ■ )
Set parameter about Ethernet of DAU.
1) Standard IP address
192.168.110.100
2) Port No.
y For RCU: 5000
y For Option/Maintenance PC: 6000
The actual IP addresses of DAU1 and DAU2 are obtained by adding the unit number to the standard IP address as below.
y DAU1: 192.168.110.101 y DAU2: 192.168.110.102
6.10.5 Option/Maintenance PC ( ■ )
Set the IP address of the PC that is connected to VDR.
1) Option PC
IP address of the PC as a real-time monitor (option)
192.168.110.200
2) Maintenance PC
IP address of the maintenance PC
192.168.110.200
3) Port No.
The port number to which real-time monitor signals are transmitted
y Sensor (NMEA) data: 50000
Notice that when the optional PC is not used, the IP address of the maintenance PC (192.168.110.200) is used as
the default setting. When any optional system is to be setup, its IP address needs to be renewed.
The IP address indicates where real-time signals (UDP/IP) are transmitted.
6.11 Configuration
The display does not appear if the password for maintenance is used to login.
( ■ ) 6.11.1
( ■ ) 6.11.1.1
( ■ ) 6.11.1.2
6.11.1.1 LAN
Set the channel “Enable” or “Disable”, though which data is transmitted to the LAN port.
6.11.1.2 COM
Set the channel “Enable” or “Disable”, though which data is transmitted to the COM port.
The reason for the COM port being used is due to the anticipation of the DCB of the DAU being used to serve other
units. However, COM port is not to be used for the VDR.
♦ Check procedure
No. Check items Execution Function Clause
1 NMEA sentence data Monitor (M) -- DAU (D) 7.1
Monitor (M) – Dry Contact (C) 7.6
2 Radar image data Setup (C) -- FGB (F) 7.2
or or
Monitor (M) -- Radar (R) 7.3
3 Audio data Monitor (M) -- Audio (A) 7.4
4 Microphone test Monitor (M) -- Event (E) 7.5
Monitor the NMEA sentence data which is collected in the DAU on real time, and check the sentence specified by
the installation drawings is collected correctly. Be sure to check the collecting data of all channels.
● Record sentence setup
● Wires between each equipments
7.1.1 Starting
1) Click “DAU (D) “ in the Monitor (M) menu, and then select the DAU to monitor from DAU1(A) and DAU2(U).
7.1.4
7.1.2 7.1.6
7.1.3
7.1.8
7.1.5
7.1.7
CH17 - CH19
The monitor of the recorded sentence when a contact signal is input into the RCU.
Refer to 5.7.7
● “Recording data”: Monitors the sentence data which is recorded in the VDR.
The sentence which is not recorded is not displayed even if it has received.
The monitor data is displayed by the sentence format currently recorded in the VDR.
● ”Recording data”
The addition and deletion of the CH to the monitor can be operated freely.
● ”All data”
Only independent CH can be monitored.
Reception data is monitored when receiving.
If the monitoring of two or more channels is carried out simultaneously, data will be mixed and they will be displayed.
When the maintenance software is quitted, please make sure that a real –time monitor has stopped
Reboot DAU, when the maintenance software has been quitted without stopping a real-time monitor. The output of real-time data
stops.
Check that the radar image data which is made to display on WEB. Check normal operation of the FGB.
● Image capture setup
● Rader wiring
Check the quality of image of the capture picture at first using a monitor 1.
[ START ] [ STOP ]
While VDR is in operation, MCB is sending a command to the FGB to capture an image. This function needs to be shut down
during the maintenance of the FGB. For this purpose, the MCB cuts itself away from FGB in order to make the FGB free from
its interference. This is called the FGB maintenance mode.
Once the FGB is set in the maintenance mode, the FGB error is displayed on the internal operation panel of RCU.
File
Back
7.2.2.1
7.2.2.2
1) Image capture
Click “Capture Image”, and the RADAR image at the time of the click is captured.
2) Display of result
FGB displays the result of the capture. Confirm that it is “OK”. After confirmation, click the [Return] button
and go back to the FGB Maintenance WEB.
→ In case the result is “NG”, do it again.
Procedures:
▪ Click [Capture IMAGE]
▪ Confirm the result and [Return]
▪ Click [PNG IMAGE]
▪ RADAR image displayed
▪ Check the captured image
By default, the parameter of CH1 is used for the setting of capture operation.
For this switching operation, the parameters of the FGB need to be changed accordingly. When two different type RADAR
units are used, which parameter should be used as the setting value of the capture conditions needs to be determined.
3) Quit “Control”
Click the “X” button in the upper right corner of the window and close the window.
Monitor the Radar Image Monitor which is recorded in the VDR at real time to check the operation is working
correctly.
7.3.1 Starting
Click “Radar (R)“ in the Monitor (M) menu.
The monitored image is displayed later than the record time several seconds
Monitor the Audio data which is recorded in the ARB at real time to check the operation is working correctly.
● Microphone unit operation
● Wiring between the RCU and Microphone unit or VHF transceiver
7.4.1 Starting
Click “AUDIO (A) “ from Monitor (M) menu.
7.4.3 1)
7.4.2
7.4.3 2)
Select the CH to monitor. More than two CH cannot be played at the same time.
For each connecting unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation.
→ Each monitor CH is mixed by 3 input signal. For checking that each unit is correctly working, it is necessary to connect
only one unit to monitor.
2) Stop playing
Click [■] button to stop monitoring.
The monitored sound is played about one second later than sound source.
Monitor the operation event of VDR at real time to check that VDR system is working correctly.
Microphone connection setup
Check that all the connected microphone test results are normal.
[Connect]
[START] [STOP]
2) Monitoring start
Click [Monitoring start] button to start monitoring.
Although the menu and button which have not been indicated in this manual exist, since it is the function which is not usually
used, explanation is omitted.
When the maintenance softwrae is quitted, please make sure tahat the a real-time monitor stopped.
Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor.
The output of real-time data stops.
Monitor the dry contact data which is collected in the NCT-57/63 on real time, and check a dry contact state
specified by installation drawings is collected correctly. Be sure to check the collecting data of all channels.
This monitor analyzes the contents of NMEA sentence data outputted from the NCT-57/63, and a dry contact
state is indicating by an icon.
● NCT-57/63 setup
● Wires between each equipments
7.6.1 Starting
1) Click “Dry Contact (C) “ in the Monitor (M) menu, and then select the DAU to monitor from DAU1(A) and
DAU2(U).
7.6.2 7.6.4
7.6.8
7.6.3
7.6.5
7.6.7
7.6.6
7.6.6.5
7.6.6.3 7.6.6.4
7.6.6.2
7.6.6.2 General dry contact ( except Door status and Engine telegraph )
A dry contact state is displayed with a lamp icon.
▪ Green lamp: A target status is normal.
▪ Red lamp : A target status is abnormal.
▪ : A door is open.
▪ : A door is closing.
When the maintenance softwrae is quitted, please make sure tahat the a real-time monitor stopped.
Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor.
The output of real-time data stops.
● Check procedure
No. Check Items Execution function Clause
1 Download of record data in the HVR Data (D) -- HVR backup (H) 8.1
2 Conversion of record data Data (D) -- Data Convert (V) 8.2
• Capsule data
• PC card data
3 Playback data Data (D) -- Playback (P) 8.3
The data currently recorded on the capsule can be downloaded to direct PC by the LAN circuit.
8.1.1 Start
[RESTART] [STOP]
8.1.2
8.1.3 8.1.5
8.1.6
8.1.4 8.1.7
8.1.4
● When the Maintenance PC cannot communicate to the RCU or the software version of RCU software is
older than "2.0.0", the dialog for selecting the type of capsule will be displayed.
Refer to the clause 8.1.7 for details. Select the type of capsule which is connected.
Since it is all data selections by the default, remove the check of unnecessary data.
Download goes back from the newest data and downloads old data.
When requiring only the newest data, several% of download is enough.
Download of the amount of whole capacity requires about 3 hours.
Since data capacity is specified and downloaded, in NMEA sensor data, audio data, and image data, the time width
reproduced is different.
As for the data of the second half(New in the record) replayed although the time when playback is started(old in the record)
is not in agreement, all data will be gathered.
2) Progress display
Progress of download is displayed by Progress bar corresponding to each partition.
The downloaded data can be played even if canceling in the halfway, because it is effective.
2) Restart recording
Click [RESTART] button in the Control screen to restart recording the data which is canceled before download
starts.
It is made to convert so that recorded data by JCY-1700 can be replayed by playback software for JCY-1700.
8.2.1 Start
Click “Data Convert (V) “ from Data (D) menu.
8.2.2
8.2.3
8.2.4
8.2.6
8.2.5
1) PC card data
Click [ATA / HVR] button to display “ATA MODE” for the recorded data in the PC card.
2) Capsule data
Click [ATA / HVR] button to display “HVR MODE” for the downloaded data from the capsule at “clause 8.1
Download function”.
1) PC card data
Click [Read browse] button to specify the drive which is currently assigned to the PC card.
2) Capsule data
Click [Read browse] button to specify the route folder of downloaded file.
All default data is selected. Take out the [9] mark from the data which is not needed.
It is impossible to understand the contents of the capsule backup data because the data is downloaded as one of the DAT file,
The record situation can be understood, if the audio data is decomposed as G726 compressed file.
Audio file does not need to be changed into WAV file if playing with audio is not needed.
Moreover, there is the selection that only the needed part can be changed to WAV file after the converting as G726 file.
Conversion abbreviation can be selected because the converting to WAV file takes long time.
→ 80% of the time to convert is for the WAV file.
This conversion function will be used when a data downloaded from HVR is replayed with the playback software for
JCY-1700.
It is unnecessary in a maintenance.
Refer to the "playback - operation manual" for the operating instructions of playback software.
9. Factory-shipments setup
Set up at the time of shipment inspection at a factory.
Usually, it is not necessary to set up at the time of onboard installation. The setup change is needed in changing
from the contents of a installation drawings.
“File”
[Back]
Program version
9.1.2.1
9.1.2.2
9.1.2.1 Download
The setting field of FGB can be downloaded.
9.1.2.2 Upload
The setting file of FGB can be uploaded. By uploading, the capture conditions of FGB can be changed.
Click [Browse] button, and then select the file to be uploaded, and click the [UPLOAD] button.
Click the [Return] button and go back to the FGB Maintenance WEB screen.
If FGB is connected to JRC RADAR equipment, the setting file with optimum parameters is uploaded at the factory. And
there in no need to set them again on site.
However, if FGB is not connected to JRC RADAR equipment. In this case, the parameters need to be set on site after
shipment.
With the intension of reducing such an inconvenience, a new way of setting parameters is under consideration on our side.
Please wait for a while.
The FGB setting file extracted from system configuration information can be uploaded by this function.
Refer to the clause 10.1.7 and 10.5.
CAUTION in the process of downloading, editing, and uploading the FGB capture setting file:
When editing the file, delete the first line. If you try to upload the file without deleting its first line, an error will be reported.
Connecting to LAN of RCU directly can set up NCT-57/63 without connecting the PC to the NCT-57/63.
● Factory setup
Simplex inspection: Can be set up with connecting directly to NCT-57/63 if COM port is used.
System inspection: Can be set up NCT-57/63 by LAN connection as same as other equipment setup.
● Installation setup (when a change setup is required)
Can be set up NCT-57/63 by LAN connection as same as other maintenance setup.
-- Communication route --
< Maintenance PC > -- < RCU (HUB) > -- < DAU > -- < NCT-57/63 >
9.2.2.2 9.2.2.4 1)
9.2.2.3
9.2.2.4 2)
9.2.2.1
9.2.2.5
9.2.2.8 9.2.2.4 3)
9.2.2.6
1) New setup
Start from the procedure of the 9.2.2 clause when a setup data is created newly for the NCT-57/63.
9.2.2.2 Connecting CH
Select CH of NCT-57/63 which connected a dry contact signal.
The sentence data for selected CH is created.
When the lamp of the state of a dry contact signal is displayed with playback software, a "normal state" will be indicated by
green and a “non-normal state” will be indicated by red.
When a contact signal means "Active" or "not Active", the contact state of "Active" is selected as a normal state.
3) Comment
A comment can be added to the end of a sentence.
Input the character strings which show the contents of a dry contact signal.
As sentence information, the connection CH of NCT-57/63 is added automatically.
● Caution
Since a maximum length of a sentence is 82 bytes, even if a long comment is inputted more than 82 bytes are ignored.
1) Selecting a sentence
Double-click the sentence displayed on the list.
It checks that CH number for deletion is displayed on the connection CH field of the 9.2.2.2 clause.
2) Deleting a sentence
Click the [Delete] button.
When engine telegraph signals are not connected with dry contact signals, the procedure of the 9.2.3 clause is unnecessary.
9.2.3.1
9.2.3.2 9.2.3.5
9.2.3.2 1)
9.2.3.2 4) 9.2.3.6
9.2.3.4
9.2.3.2 2) 9.2.3.4 1)
9.2.3.2 3)
9.2.3.3 9.2.3.7
9.2.3.8
9.2.3.10
9.2.3.9
3) Selecting connection CH
Select the connection CH of NCT-57/63 with a pull-down menu.
9.2.5.5
9.2.5.4
9.2.5.7
9.2.5.3
9.2.5.2
9.2.5.6
9.2.5.1
● When COM connection is selected, it becomes impossible to set up 9.2.5.2 and 9.2.5.3 .
Click the [OK] button to continue transmission and reception. The dialog for saving a file is displayed.
A communication link is started after saving file.
Check that DSC shown on the dialog is the same as DSC to set up.
Click the [Yes] button when the DSC shown on the dialog is right. Transmitting the setup file to the DSC
is started.
Check items: • The number of DAU
• The channel number of DAU which is connected to the DSC
• The type of DSC (NCT-57 or NCT-63)
Accidentally, even if the setup file is transmitted conversely, the DSC cannot generate an error alarm.
Wrong data will be recorded as a result. Be careful enough and operate it
The setup file of DSC is recorded to the Capsule via ethernet link too.
When the Maintenance PC can communicate to the capsule, click the [Yes] button. Transmitting the setup
file to the Capsule is started.
4) Completion of a setting
When transmission to the DSC and the Capsule completes, a dialog will be closed and it will return to a main
window.
1) Sentence data
Check the definition field of "%C from the registering sentence in the list window of 9.2.2.6 clause.
● Used character
- "V" or "A": "V" = Normal, "A" = Abnorml
- "N" or "H": "N" = Normal, "H" = Abnormal
- "O" or "C": "O" = Open, "C" = Close
4) Operation position
B = Bridge P = Port wing S = Starboard wing C = Engine control room E = Engine side / local
W = Wing (port or starboard not specified)
- Reference –
● This function is not used to maintain the optional built-in A/D converter board to the DSC (NCT-57/63).
The setting of the built-in A/D converter board to the DSC is operated with the strap pins on the PCB
The setup of NQA-4091A is possible via LAN of RCU without connecting PC with NQA-4091A.
● Factory setup
Simplex inspection: Can be set up with directly connecting to NQA-4091A by using COM port.
System inspection: Can be set up NQA-4091A by LAN connection as same as other maintenance setup.
● Installation setup (when a change setup is required)
Can be set up NQA-4091A by LAN connection as same as other maintenance setup.
-- communication route --
< Maintenance PC > -- <RCU ( HUB) > -- < DAU > -- < NQA-4091A >
● The setting preparation according to this item is required only at the time of a new setup at a factory.
● In changing the range of the A/D module (6B12) set up at the factory, there is no necessity for "new setting preparation."
→ Start from the clause 9.3.2.
However, when A/D module needs to be added (Changed), "new setting preparation" explained according to this item is needed.
In setting up A/D module (6B12) newly, mount A/D module according to the following.
1) Take out 6B12 module that is mounted on the Slot1 (configuration slot) of back plane with D-SUB25
connector. → Take it out upward after taking out the screw for holding 6B12.
3) Jumper setup
Short-circuit with the configuration jumper (W1) on the left of Slot 1 (configuration slot) of back plane.
Initial setting of a A/D module can be set by short-circuited with configuration jumper (W1).
The communication rate at the time of initial setting is compulsively set to 9600bps.
It is necessary to change a communication rate setup of DAU into 9600bps.
Use the Setup function (See 6.6) of DAU and change the communication rate of the A/D connection CH into
9600bps.
9.3.2 Starting
Click the “Analog” from “Option” in the “Setup” Menu.
9.3.6 9.3.8
9.3.10
9.3.5 9.3.11
9.3.3
9.3.7
9.3.9
9.3.4
Since new setting preparation of the 9.3.1 is omitted, when a range setup at the time of onboard equipment changes, the
jumper setup has "Jumper Open" selected.
The address selection is needed only when the configuration jumper is “Open”.
When it is “Short”, only A/D module of slot 1 can be setup. Selection of the A/D module address is not need.
If the configuration jumper is shorted, the A/D module address is setup to the slot 1 is displayed at the address field.
1. The item which can be changed at the onboard is only an input range [Range].
Since it may become impossible to use in this system if other items are changed, do not change.
2. If it is changed to voltage range (+/- 10V or +/-1V Range etc) from +/- 20mA Range, 50Ω current conversion resistor
(AC1381) will be needed. Prepare in beforehand.
· 50Ω current conversion resistor (AC1381) code: 5EZFE00015
3. Conversely, if it is changed from +/- 20mA Range to voltage range (+/- 10V or +/- 1V Range etc), 50Ω current
conversion resistor (AC1381) must be removed.
In a new setup, set all A/D modules to a slot 1 one by one, and set up with the procedures from 9.3.8 to 9.3.10.
3 When you want to search for the program version. Setup (C)
· RCU: ”MCB-Application”, ”ARB”, ”FGB” -- RCU (C) 5.4
· DAU: ”DCB-Application” -- DAU (D) 6.4
· RCU: ”MCB-Boot”, ”MCB-Application” Control (R) 10.1.4
· DAU: ”DCB-Boot”, ”DCB-Application” -- Control (R)
· Maintenance software Help (H) 10.7
-- Version (A)
4 When you want to set the present time same as the VDR system. Control (R) 10.1.6
(The time is set automatically if GPS is connected) -- Control (R)
5 When you want to initialize the system data of the RCU and DAU. Control (R) 10.1.8
-- Control (R)
6 When you want to research the reason why the RCU and DAU are restarted by Control (R) 10.1.10
the WDT (Watch Dog Timer). -- Control (R)
A WDT generating factor code can be found.
The number of times of WDT generated in the past can be found. System (S) 10.3
-- System Log (L)
7 When the program upgrading has failed and the RCU and DAU normal operation Control (R) 10.1.9
is not working. -- Control (R)
8 When you want to investigate the cause in which the VDR system has generated a System (S) 10.4
fault. -- Event Log (E)
Refer to the past event log file.
TXT and the CSV file will save the referred event.
Excel etc will reference the saving file.
The event file references the receiving file by the saving the file of PC card or
the following function.
Preparing the function to receive the past event file via LAN. Control (R) 10.1.12
-- Control (R)
9 When you want to investigate the details of the error generated in the VDR. System (S) 10.2
The error factor can be checked remotely by the Maintenance PC, without -- System Status (S)
seeing the Internal Operation Panel of the RCU.
10 When you want to reference the contents of the NMEA sentence data recorded by Data (D) 10.6
the VDR via the text editor or Excel. -- Log to TXT (T)
11 When you want the setting file of the RCU and DAU. Setup (C)
The setting file of the RCU and DAU can be received and saved. -- RCU (C) 9.3
-- DAU (D) 10.3
The setting file of the RCU, FGB and DAU can be extracted and saved from the Data (D) 10.5
system configuration information file saved on the PC card. -- Config (C)
The setting file of the RCU, FGB, and DAU which are recorded on the capsule Control (R) 10.1.5
can be received and saved. -- Control (R)
10.1.2 10.1.3
10.1.4 10.1.5
10.1.6 10.1.7
10.1.8
10.1.9
10.1.10 10.1.11
10.1.12
• To stop recording • To restart recording • To set Alarm ACK • To compulsively reset initial error
These operations can be done from the maintenance PC.
The other operations are not recommended.
Button Function
RESTART To restart recording
STOP To stop recording
BACKUP To eject PC card
FUNC To display the program version information by LED
ACK To set the alarm ACK
FUNC + RESTART To compulsively reset the initial error
FUNC + BACKUP To backup the data in the Capsule to the PC card
FUNC + STOP To immediately stop the backup operation
1) Download
Click the [Download] button, and the downloading of the data begins.
The time & date of DAU is supposed to be corrected on the ZDA sentence base.
Use this function when time correction at the minute unit is needed before GPS is connected to DAU.
The setting data of the RCU and DAU are uploaded if the [Reboot] button is operated in the setup of system configuration
information of the RCU and DAU as described in the paragraph 5.6.
A reboot of the RCU and DAU should generate "an Initial error", without operating the [Reboot] button. In this case, cancel the
error by the [FUNC+RESTART] operation described in paragraph 10.1.2. (Button operation of the internal operation panel of the
RCU is also possible.)
This operation can be fixed as "Operation", when the upgrading of the program has failed and does not operate
as “FUNCTION=Download” when displayed.
If a HEX code of 8 digits is displayed, contact the technical support division of JRC.
While VDR is in operation, the MCB is sending a command to the FGB to capture the image. This function needs to be shut
down during the maintenance of the FGB. For this purpose, the MCB cuts itself away from the FGB in order to make the FGB
free from interference. This is called the FGB maintenance mode.
Once the FGB is set in the maintenance mode, the FGB error is displayed on the internal operation panel of the RCU.
The downloaded event file is the same as the file saved on the PC card.
The method of getting the event history file can be selected from the following.
• Downloading from the LAN connection (This operation)
• Copy from PC card
Refer to the operation of the “Event Log” (paragraph 10.4) when the downloaded event file is opened.
10.1.13 Quitting
Click the [×] button in the upper right corner of the window.
The operating status and the error detail information are displayed.
The error display of the internal operation panel of RCU displays the error as a representation of each factor.
Check the error detail information from the system status display.
When the alarm buzzer of the VDR is sounded, the error factor can be checked without looking at the internal operation panel of RCU.
► CAUTION ◄
There are only OK and NG because the system status display has 1 Bit.
In the case of NG, it is accepted as NG. It cannot necessarily be accepted as normal operation when OK is displayed.
Example) DAU: The CH which is not connected to the sensor equipment is also displayed as OK.
Microphone test at the time of starting: OK is displayed even before testing the microphone.
1) Receive
If [Receive] button is clicked, the data is received and the newest system status is displayed.
2) Cyclical Receive
Click of the [Cyclical Receive] button, system status data is received every 5 seconds.
→ The newest system status is updated periodically.
The [Cyclical Receive] button changes to the [Stop] button during cyclical receiving.
Click [Stop] button when stopping cyclical receiving.
10.2.4.4
10.2.4.6
10.2.4.5
10.2.4.7
10.2.4.8
10.2.4.9
10.2.4.11
10.2.4.10
10.2.4.12
10.2.4.1 Initial
”Initial” error is displayed.
1) Factor
The RCU compares each system configuration information on the RCU and the HVR when RCU is started.
If the system configuration information is not in agreement, it is detected as an initial error.
→ It is checking that the system configuration information in the HVR is recorded correctly.
2) Correspondence
Perform the operation as ”FUNC + Restart” by Remote Control function or from internal operation panel.
When the MIC test of 9 microphones is completed, it will be a waiting for a maximum of 30 minutes.
Check the result of a microphone test using the real-time event monitor.
1) Factor
The VDR outputs the test tone from the speaker with the built-in microphone in the cycle of 12 hours or at
the time of starting and checking the input signal of the microphone. The MIC error is determined when
input signal is out of standard.
2) Correspondence
• A microphone unit is out of order.
→ The connection of the microphone might need to be changed .
• Fault wiring
→ Check the wiring.
• Fault setting
→ Check that the microphone unit is connected to all the enable microphone CH.
• Surround noise
→ Restart the RCU after the background noise becomes low.
- Reference -
Specifying the operation of a microphone test
● Microphone test timing
• When starting
• The cycles of 12 hours from starting
• The microphone test is performed every 1 hour from the time of error generating only error CH.
( After results of MIC test become to normal, MIC test is performed as same timing as other MIC. )
● Record operation condition
Audio data is recorded from microphone unit even if MIC error occurs.
(No-sound may be recorded when the microphone unit is out of order)
10.2.4.3 DAU
The detail factor of ”DAU” error is displayed.
No. Items Factor Correspondence
1 Ethernet connection alarm Ethernet connection is cut. Check wiring.
Check power supply.
Check IP address.
2 DAU system alarm The inside error of DAU Check the system status display of DAU.
3 DAU data alarm NMEA Sentence is not receiving normally in Check the object CH from system status
some CH of DAU. display of DAU.
10.2.4.4 Battery
The state of a blackout signal is displayed.
Green lamp: Normal
Red lamp: Blackout
10.2.4.5 FAN
Failure of FAN in the power supply unit is displayed.
1) Factor
Either one or both of the fans in the power unit is out of order.
2) Correspondence
Replace both fans.
10.2.4.6 Capsule
The detail factor of ”Capsule” error is displayed.
● Ethernet
When the Ethernet connection cannot be connected with the HVR.
● Write connection error
When the connection of the Write socket for each partition cannot be connected.
● Status connection error
When reading the value of the BER from the object partition has failed.
10.2.4.7 BER
The detail status of the “BER” error is displayed.
● Result of the BER check for each partition
● BER count value of each partition
1) Factor
HVR is out of order.
The temporary failure due to very excessive temperature condition.
2) Correspondence
In order to check whether a condition changes or not, wait for several days.
If the BER error is canceled automatically, the error occurred temporarily and is not important.
If the error continues, consult with a Mitaka plant on a solution.
- Reference -
About BER
The HVR records the data in the built-in F-ROM.
The recording procedure for this F-ROM is performed as follows:
Write → Read → Verify
It counts the number of Verify error as BER.
10.2.4.8 Mode
The operation mode of RCU is displayed.
No. Items Mode
1 RCU online 0: Offline
1: Online
2 Booting with recovered configuration data 0: Normal
1: Data recovered from FLASH ROM
3 Booting with default configuration data 0: Normal
1: Default configuration
4 Blackout 0: Normal
1: Blackout
10.2.4.9 PC card
The detail factor of “PC card” error is displayed.
No. Items Factor Correspondence
1 Opening failure of PC card PC card fault Format the PC card
Exchange the PC card when not
2 Detection failure of PC card being recovered by formatting.
3 Un-loading of PC Card for 10 minutes It take over 10 minutes without Load the PC card.
PC card.
8 Reserve
9 Reserve
LAN information
IEC61996
System information
7 EEPROM reading error EEPROM fault Exchange EEPROM.
9 FLASH ROM checksum error Abnormal checksum of system setup Setup the data.
MAC address which is saved in F-ROM for back up
LAN information
IEC61996
System information
10 FLASH ROM writing error F-ROM fault Exchange the MCB.
2 Time-out of Initialization
7 Receiving failure of image data Receiving failure of image data. Check whether image data can be
received in a browser (IE).
8 No response to a command The no response error to a command. Exchange FGB, if you cannot
receive, even if it restarts.
9 Sleep mode by blackout The sleep mode by blackout. Return on the power.
10 Real time monitor request error The UDP transmission IP address to Set up the IP address of
FGB has not been set up. Transmission.
10.2.5.1
10.2.5.2
10.2.5.3
10.2.5.4
10.2.5.1 NET
”NET” error is displayed.
1) Factor
The DAU cannot be connected with RCU via Ethernet.
2) Correspondence
• Check the wiring
• Check the power supply of RCU and DAU
• Check the IP address setup
1) Factor
• The sensor equipment fault
• The wiring fault between sensor equipment
• The setup fault
2) Correspondence
• Check the signal output from the sensor equipment.
• Check the wiring.
• Check the setup (filter setup, receiving interval setup etc.)
DIP-SW
• ON: Check the receiving error.
• OFF: No check the receiving error.
When the sensor equipment does not output the sentence periodically, turn off the object CH of DIP-SW on PCB (DCB) of the
DAU. Receiving error of the CH is not checked by the DAU.
10.2.5.3 Mode
The operation mode of DAU is displayed.
LAN information
IEC61996
CH01-- CH16
System information
6 EEPROM reading error EEPROM fault Exchange EEPROM.
8 FLASH ROM checksum error Abnormal checksum of the system Reset up the data.
MAC address setup which is saved in F-ROM for
backup.
LAN information
IEC61996
CH01-- CH16
System information
9 FLASH ROM writing error Abnormal F-ROM Exchange DCB.
Confirm the counter value of WDT (self –reset by abort ) on RCU and DAU.
Confirm the counter value of WDT at installation and maintenance on the board.
Contact the factory when RCU or DAU counted.
“Tab”
[Receive]
[Clear]
2) Receiving data
Click the [RECEIVE] button, and the counter value of WDT is displayed.
“writefile.txt”
· Downloading from RCU: It is saved in the selected folder.
· PC card: It is saved in the “event” folder of the PC card.
1) Sorting
Past event log data can be displayed and sorted.
Click the head title of target column and it will be displayed and sorted by the contents of the column.
2) Saving a file
Past event log data can be saved at a “txt” or “CSV” type file.
Click “Save (S)” of “file” menu.
The setup file for each unit can be created from a system configuration file.
10.5.2
10.5.3
10.5.4
10.5.5
The “Log” files of NMEA sentence can be converted into a text file.
10.6.2
10.6.3
10.6.4
BLANK PAGE
11.1.2
11.1.3
11.1.4
► Caution ◄
Do not make the set file type and the upgrade file contradicting.
The operation is stopped, if upgrade which was wrong as follows is performed.
Example) The application of RCU has been uploaded into DAU.
11.1.4.1 LAN
Destination IP address and the port number are needed to set up when LAN is selected. However, it is not
necessary to change because it is set up automatically by selecting the unit of 11.1.2.
It is necessary to set up only when IP address of RCU and DAU is changed from the default value by the option system.
11.1.4.2 COM
If COM is selected, COM number which is used in the maintenance PC need to be inputted.
11.1.5
“Progress bar”
“ Progress message”
The object unit is restarted automatically and start operation with upgrade program after the upload is complete.
It is not necessary to reset up the system composition information by upgrade.
If the upgrade to need occurs, it tells about by technical information.
FGB (CKA-129)
部品面
Side of parts
S2
1
OFF ON
11.2.3 Starting
Click ”FGB (F) “ from “Version up (V)” menu.
11.2.4
11.2.5 11.2.6
There are two different kinds of the program file as ”Application” and ”Boot”.
The detail information about file to upgrade or etc. is told by technical information.
It is necessary to set up only when IP address of the FGB is changed from the default value by the option system.
2) The difference between the Japanese version and the English version
• The message language of the installer becomes Japanese/English.
• The event message of EVENT function becomes Japanese/English.
→ Object function: ”EVENT Log”, ”EVENT Monitor”
All display languages other than the above are English notations.
When the old version of the maintenance software has previously been installed, uninstall and perform the setup. Refer to
12.3.
1) Performing “setup.exe”
Double-click ”setup.exe” file.
2) Starting installer
When [Next >] button appears, click it after displaying the following window.
3) User information
Input “jrcvdr” into the serial number block and click [Next >] button.
(Installation can be completed without inputting the user name and the organization.)
5) Starting installation
Click [Install ] button to start the installation.
8) Starting installation
Click [Next >] button to start the installation.
9) Completing installation
The shortcut for the “Maintenance Software” of the JCY-1700 will be placed on the desktop.
Double-click it to start.
12.3 Upgrade
If the old version is installed, install after deleting the following application from the ”Control Panel”
- ”Add/remove Programs” of Windows.
* If the installation is performed without deleting, the message which directs deletion is displayed.