Aex
Aex
Aex
2015 / 2016
Input Sources
Output Impedance 600 Ω (Unbalanced at 1 kHz) 600 Ω (Unbalanced at 1 kHz) 600 Ω (Unbalanced at 1 kHz)
Output Level -72 dB +/- 3 dB (at 1 kHz) -72 dB +/- 3 dB (at 1 kHz) -72 dB +/- 3 dB (at 1 kHz)
Material & Finish Diecasted zinc alloy Diecasted zinc alloy ABS. matt black & grey
with steelmesh. with steelmesh.
metallic quartz grey/silver metallic quartz grey/silver
The unit features a Background Music (BGM) mode which when triggered allows the user to play all the pre-stored music files in the
SD Card. The unit is suitable for applications in factory environments where its easily accessible messages can triggered to signify
end/start of shifts, in shopping malls and hotel environment where it can serve as a BGM source with thousands of music files to
enhance the ambient environment. The DS 201-S can also be integrated with the fire alarm panel, providing automatic evacuation or
warning messages in the event of an emergency.
Technical Specifications
DS 201-S
Weight 2.2 kg
MC 3, MP 2 Desktop Microphone
Technical Specifications
The MC 3, and MP 2 are Desktop Microphones range MC 3 MP 2
which promote simplicity and exceptional quality. The MC Connector 6.3 mm phone socket 6.3 mm phone socket
3 ( 0 dB output ) features an ascending and descending 2 nos. 2 way panel feed through 1 no. 2 way panel feed through
connector connector
4-tone chime. Dual-colour LED indicators clearly display
Indicator Type Chime in progress / Talk indicator
paging status while the entire unit are aesthetically
designed. Audio Signal Output 0 dBV, 600 Ω (Balanced) -60 dBV, 500 Ω (Balanced)
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
01
MEDUSA 3
Integrated PA System
The Medusa 3 Series was developed with a clear objective, a Public Address System that was reliable and easy to use. A single box solution
suitable for virtually any small-to-medium scale Public Address system application. The Medusa 3 Series consist of the Master Unit with a built in
power amplifier making it an extremely easy to deploy standalone PA System.
The Master unit is also versatile and provides up to 12-zones coverage. The Master Unit can be expanded with a Slave Unit, increasing the
systems amplification power as well as zones up to a maximum of 24-zones. The Medusa 3 Series can be complimented with a Medusa MEI 60
Automatic Evacuation Interface, allowing for a fully automated ‘sandwich’ (N+1, N, N-1) evacuation with built in message.
The Medusa 3 also comes with a built in amplifier monitoring and automatic changeover circuit to switch over the internal Master or Slave power
amplifier to an external standby amplifier upon failure. Coupled with a built-in siren and handheld emergency microphone the Medusa 3 Series
satisfies the growing need for building evacuation systems.
Technical Specifications
MED 306M MED 312M MED 306S
Rated Power Output 600 W at 100 V line 1200 W at 100 V line 600 W at 100 V line
Input Sensitivity
Remote Mic 0 dB Balanced 0 dB Balanced
Line 1 0 dB Balanced 0 dB Balanced
AUX 1 - 3 RCA Connector, -20 dB Stereo RCA Connector, -20 dB Stereo
Protection Circuit Over current & short circuit protection Over current & short circuit protection Over current & short circuit protection
with resettable fuse with resettable fuse with resettable fuse
Power Requirement 220 ~ 240 Vac, 50/60 Hz, 853W 220 ~ 240 Vac, 50/60 Hz, 1706W 220 ~ 240 Vac, 50/60 Hz, 853W
or 24 Vdc, 22.9 A or 24 Vdc, 44.8 A or 24 Vdc, 22.9 A
Dimensions (W x H x D) 430 x 132 x 500 mm 430 x 132 x 500 mm 430 x 132 x 500 mm
Weight 26 kg 39 kg 26 kg
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
02
MEDUSA 4
Integrated Signal Manager
MEDUSA 4
MED 400P Integrated Signal Manager
The Medusa 400P Integrated Signal Manager is a versatile public address pre-amplifier unit based on the key features of the Medusa 3
Series. The Medusa 400P Integrated Signal Manager comes with a built-in 12 zone line selector and is scalable with external LS 12A
Speaker Line Selector for a maximum of 60 zones.
The Medusa 400P is designed to be used with external power amplifiers making it a highly scalable suitable for any medium - to - large
scale projects. The Medusa 400P can be supplemented by a host of AEX System products such as automatic amplifier changeover unit,
Medusa Automatic Evacuation Interface and Remote Microphones.
Technical Specifications
MED 400P
Input Sensitivity
Remote Mic 0 dB Balanced
Line 1 0 dB Balanced
MED 400P AUX 1 - 3 RCA Connector, -20 dB Stereo
Weight 5.0 kg
The unit has internal storage for evacuation messages and can be
Power Requirement 24 Vdc, 0.4 A
configured to conduct (N+1, N, N-1) sandwich evacuation
procedure or a simple ALL CALL total evacuation. The unit is Dimensions (W x H x D) 430 x 150 x 44 mm
features 60 dry contact inputs.
Weight 1.8 kg
MEI 60
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
03
MEDUSA 5
Public Address & Emergency Voice Alarm Control System
MEDUSA 5
Public Address & Emergency Voice Alarm Control System
Technical Specifications
MEDUSA 54 (with built-in 480W power amplifier)
MEDUSA 52 MEDUSA 54
MEDUSA 52 (with built-in 240W power amplifier) Rated Output Power 240 W 480 W
Voice Alarm Controller Frequency response (at rated output) 40 Hz to 18 kHz
Output and load impedance 100 V (42Ω) 100 V (21Ω)
Signal-to-Noise Ratio Better than 80 dB
The MEDUSA 5 provides audio pre-amplification, signal routing, Total Harmonic Distortion < 0.5% (at rated output, f=1 khz)
remote microphone management, automated voice alarm with fire Input Sensitivity
alarm interface, system configuration & monitoring, power AUX 1 -20 dBv (20 kΩ Unbalanced) RCA Connector
AUX 2 -20 dBv (20 kΩ Unbalanced) RCA Connector
amplification & amplifier monitoring. The MEDUSA 5 is suitable for
AUX 3 -20 dBv (20 kΩ Unbalanced) RCA Connector
systems that requires a straight-forward automated voice alarm LINE IN -60/0 dBv (10kΩ Balanced) RJ45 Connector
function. Remote Microphone Input 0 dBv (600 Ω Unbalanced) RJ45 Connector
Output
LINE OUT 0 dBv (100 Ω Balanced) RCA
REC OUT 0 dBv (100 Ω Stereo) RCA
MAR 0 dBv (600 Ω Stereo) RJ45
External Amplifier 0 dBv (600 Ω Stereo) RJ45
Communication control
R-COMM RJ45
USB Connection USB 2.0, Type B
Dry Contact Control
Control Input (1-6) Control Input
Time Scheduler Control Output
MEDUSA 52 / 54
Fault Control Output
Emergency Override Control Output
Amplifier Changeover Built - In
Power Requirements 220 - 240 Vac, 50 Hz
Power Consumption 343 VA 686 VA
Backup Battery Power Requirements 220 ~ 240 Vac, 50 Hz, 352 W 220 ~ 240 Vac, 50 Hz, 704 W
or 24Vdc, 15 A or 24Vdc, 25 A
Power Consumption 12 W 24 W
Connector RJ 45 RJ 45
Output Zones 12 24
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
04
MEDUSA 5
Public Address & Emergency Voice Alarm Control System
Power Consumption 4 W
Connector RJ 45
Technical Specifications
MRE 12
Switches 12 Individual Group Switches,
Connector RJ 45
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
05
eMatrix
extension frame for additional module cards. No. of Card Slot per Frame 10
The eX 802A has all the features found in the eX 801A except that it houses an additional eX 802A
Standby Central Processing Card (CPC) which automatically takes over the operation of the Power Requirement 24 Vdc (Regulated), 1.5 A
Main CPC in the event of a fault. This feature avoids operational down time and eliminates the No. of Central Processing Card 1 no. eX 821A, 1 no of eX 822A
need to have a fully redundant system as a backup which is much costlier and difficult to No. of Power Supply Inlet Card 1 no. eX 881A
maintain. No. of Card Slot per Frame 9
eX 803A
The Extension Frame is used when additional modules cards are needed to cater for a more
Power Requirement 24 Vdc (Regulated), 1.5 A
extensive public address system. An audio & data bus connects the main frame to the
extension frame. The eX 803A features ten card slots, Extension Card, Power Supply Inlet No. of Extension Card 1 no. eX 824A
Card and a front facial Power Indicator. No. of Power Supply Inlet Card 1 no. eX 881A
No. of Card Slot per Frame
10
Indication Power
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
06
eMatrix
The eX 821A coordinates the activities of the module cards and eX 821A
performs the automated simultaneous voice evacuation during Connector 1 No. RJ45 Connector
1 No. DB9 Male Connector
emergency. The card has a built-in Real Time Clock, CPU fault 1 No. DB9 Female Connector
detection circuit and it is also able to communicate with the other Power Requirement Supplied by Main / Extension Frame
will automatically take over the entire operation. The switchover is Power Requirement Supplied by Main / Extension Frame
eX 823A Main Frame Extension Card eX 824A Extension Frame Extension Card
This card provides output terminals to extend the This card receives audio and data signals from the eX
audio and data buses from the main frame to the 823A and extends them to the modules housed in the
additional modules housed in the extension frame. extension frame. It also extends the audio and data buses
from the extension frame to the next extension frame.
Technical Specifications
eX 823A
Technical Specifications
Connector 4 Nos. RJ45 Connector
eX 824A
Power Requirement Supplied by Main / Extension Frame
Connector 8 nos. RJ45 Connector
Technical Specifications
eX 831A
No. of Channel 2
settings for a wide range of input levels and individual gain Low Frequency Filter (100 Hz) -15 dB to + 15 dB Boost & Cut (Adjustable)
potentiometer. The card can also provide phantom power to a -15 dB to + 15 dB Boost & Cut (Adjustable)
Distortion
condenser microphone if required. High Frequency Filter (10 kHz) < 0.5%
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
07
eMatrix
Remote Microphones or a combination of four Emergency Connectable eX 861A, eX 862A, eX 863A, eX 864A
Microphones and four Remote Microphones. Microphone eX 865A, eX 866A, eX 867A, eX 868A
Technical Specifications
eX 836A Audio Output Card eX 836A
outputs with individual gain control via the Control Manager Output Level & Impedance 0 dBV, 600 Ω (Balanced)
software. A dry contact output is available to provide external Control Output NO or NC Dry Contact (max. 24 Vdc, 1 A)
control which can be used for overriding the audio attenuator
Connector 2 nos. RJ45 Connector;
when the channel is activated. The module either connects 1 no. 1 x 4-pin Panel Feed
Through Connector
directly to the power amplifier inputs or through the automatic
amplifier changeover unit for amplifier changeover purposes. Power Requirement Supplied by Main / Extension Frame
Technical Specifications
eX 841A
No. of Channel 16
eX 841A Control Input Card
Sensing Method Dry Contact or Current Loop
The eX 841A provides up to 16 opto-isolated control sensor ( jumper selectable )
inputs to receive external dry contact signals which will be Dry Contact Method NO
transmitted to the Central Processing Unit to perform the next Current Loop Method Released Voltage 24 Vdc, 5 mA
instruction.
Connector 4 nos. RJ45 connector
Technical Specifications
eX 842A
eX 842A Control Output Card
No. of Channel 16
The eX 842A Control Output Card provides up to 16 Triggering Method NO or NC Dry Contact
( jumper selectable )
make/break relay dry contact output signals to any external
system. Each contact is able to withstand a voltage of up to Withstand Voltage 24 Vdc, 250 mA
Material & Finish Mild Steel; Epoxy Coated Power Handling Supplied by Main / Extension Frame
Weight 100 g
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
08
eMatrix
Technical Specifications
Output Level & Impedance 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced
Gooseneck Microphone Unidirectional electret Unidirectional electret Unidirectional electret Unidirectional electret
conderser microphone conderser microphone conderser microphone conderser microphone
Volume Control Microphone Level Microphone Level Microphone Level Microphone Level eX 862A
Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker
Level Control, Siren Level Control, Siren Level Control, Siren Level Control, Siren
Level Control Level Control Level Control Level Control
Auto Mic OFF 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min.
Communication Distance 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable)
Power Requirement 24 Vdc (Regulated), 0.18 A 24 Vdc (Regulated), 0.2 A 24 Vdc (Regulated), 0.2 A 24 Vdc (Regulated), 0.32 A
eX 864A
Material & Finish ABS Resin & Aluminium, Epoxy Coated Black
Dimension ( W x H x D ) 265 x 64.5 x 185 mm 265 x 64.5 x 185 mm 265 x 64.5 x 185 mm 475 x 64.5 x 185 mm
Technical Specifications
Output Level & Impedance 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced
Gooseneck Microphone Unidirectional electret Unidirectional electret Unidirectional electret Unidirectional electret
conderser microphone conderser microphone conderser microphone conderser microphone
Frequency Response 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz
eX 865A
Signal-to-Noise Ratio > 60 dB > 60 dB > 60 dB > 60 dB
Volume Control Microphone Level Microphone Level Microphone Level Microphone Level
Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker
Level Control, Siren Level Control, Siren Level Control, Siren Level Control, Siren eX 866A
Level Control Level Control Level Control Level Control
Auto Mic OFF 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min.
Number of Connectable Units 8 (Include Emergency Mic) 8 (Include Emergency Mic) 8 (Include Emergency Mic) 8 (Include Emergency Mic)
Communication Distance 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable)
Power Requirement 24 Vdc (Regulated), 0.18 A 24 Vdc (Regulated), 0.19 A 24 Vdc (Regulated), 0.23 A 24 Vdc (Regulated), 0.31 A
Material & Finish ABS Resin & Aluminium, Epoxy Coated Black
Dimension ( W x H x D ) 210 x 64.5 x 185 mm 210 x 64.5 x 185 mm 210 x 64.5 x 185 mm 430 x 64.5 x 185 mm
eX 868A
Weight 1.2 kg 1.2 kg 1.2 kg 1.2 kg
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
09
VECTUS VL Series
Centralised Network PA System
This allows for the implementation of a centralised PA system with VECTUS array of paging and surveillance features. The VL Series also makes
previously unattainable integration of the conventional PA system with other building services possible. TCP/IP compliant systems such as the Fire
Alarm System, CCTV System, Intrusion System and Building Management System can now be integrated to provide instantaneous voice assisted
response to each system. All these are accomplished within a single network system.
Provides RS 485 and RS 232 data communication ports Audio Output 0 to +4 dBV (Adjustable) , 600 Ω (Balanced)
for interfacing with conventional PA System. Level & Impedence
VL 31
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
10
VECTUS VN Series
Distributed Network PA System
The VECTUS VN Series Distributed Network PA System is built on VECTUSnet, AEX SYSTEM’S own TCP/IP based
proprietary network communication protocol that provides a platform for integration of Digital Audio, Video & Data
information. With VECTUS, any audio input can be dynamically routed under software control to any audio output on the
network in any combination, providing unparalleled routing flexibility; all over standard Ethernet.
Full remote control over the network is a standard part of the protocol with re-routing of audio easily accomplished via
software rather than with expensive re-cabling or use of dedicated analog switching. Use of standard Ethernet wiring
further reduces costs. Most facilities have a data network that carries computer files, HVAC control, security, etc. Network
PA technology allows for the co-existence of audio and data traffic over existing standard Ethernet infrastructure resulting
in substantial savings in design and installation.
With previously unattainable routing, control and monitoring flexibility, reduced system set-up and installation costs and
delivery of high quality audio, VECTUS is set to introduce a whole new meaning of a Digital Public Address System.
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
11
VECTUS VN Series
Distributed Network PA System
High-Low signal and variable voltage analog signals such as Indicator 3 nos- LED status indicator
Trigger Menthod NO Dry Contact
from a temperature sensor. The unit also provides 5 digital open
No. of Control 5 nos. Control Input &
VN 31A collector output signal which can be used to trigger relays or 5 nos. Control Output
connect to other devices for external trigger. Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W
receiving 10 digital High-Low signal and variable voltage analog No. of Control 10 nos. Control Input
VN 34A signals such as from a temperature sensor. Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W
interfacing with sensors, switches and third party Indicator 1 no. LED status indicator
equipments that are not network enabled. The unit is capable of Trigger Menthod NO Dry Contact
No. of Control 10 nos. Control Input
receiving 10 digital High-Low signal and variable voltage analog
VN 35A Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W
signals such as from a temperature sensor.
Technical Specifications
VN 41
Input Sensitivity Single Channel, 0 dBV, Stereo (Unbalanced)
Frequency Response 22 Hz ~ 20 kHz
VN 41 Single Channel Network Audio Insert Distortion < 0.1% @ 0 dB
Au d io F o rm a t MP E G 1/Lay er 3 wi th 8 ~ 192 k bps
The VN 41 accepts one stereo channel of analog audio and Constant Bi t Rate
streams it into a 10/100 Mbit Ethernet network system with a Network Interface RJ 45, 10/100 Mbps E ther net ( A uto) , TCP/IP
source address to allow it to be routed to any receiving device Connectors 1 no. Single RJ45 w/LED Network Socket
1 no. Single RJ45 Socket , 1 no. RCA Stereo Jack
connected to the network. The System Manager assigns its 1 no. 2 Way Panel Feed Through Connector
VN 41 2 nos. 4 Way Panel feed Through Connector
destination according to the requirements of the user. Indicators Power, Input Signal and Line In Control
Line Control Input 1 no. Of Dry Contact Input
Control Input 2 nos. Of Dry Contact Input
Control Output 2 nos. Of Normally Open Dry Contact,
Withstand Voltage 24 Vdc, 5 mA
Power Requirement 220 ~ 240 Vac, 50/60 Hz, 11 W
Technical Specifications
VN 44
Input Sensitivity Single Channel, 0 dBV, Stereo (Unbalanced)
Frequency Response 22 Hz ~ 20 kHz
VN 44 4 Channel Network Audio Insert Distortion < 0.1% @ 0 dB
Au d io F o rm a t MP E G 1/Lay er 3 wi th 8 ~ 192 k bps
The VN 44 accepts four stereo channels of analog audio and Constant Bi t Rate
Network Interface RJ 45, 10/100 Mbps E ther net ( A uto) , TCP/IP
simultaneously streams it into a 10/100 Mbit Ethernet network
Connectors 4 nos. RJ45 w/LED Network Socket ,
system with individual source addresses which allows it to be 4 no. RJ 45 Socket
VN 44
routed to any receiving device connected to the network. The 4 nos. RCA Stereo Jack , 10 nos. 4 Way Panel
feed Through Connector
System Manager assigns their destinations according to the
Indicators Power, Input Signal and Line In Control
requirements of the user. Line Control Input 4 nos. Of Dry Contact Input
Control Input 8 nos. Of Dry Contact Input
Control Output 8 nos. Of Normally Open Dry Contact,
Withstand Voltage 24 Vdc, 5 mA
Power Requirement 220 ~ 240 Vac, 50/60 Hz, 22 W
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
12
VECTUS VN Series
Distributed Network PA System
audio, ready to be fed into a power amplifier. Each channel has a unique MAC address for the I n p u t Se n sitivity Single Channel 0 d BV, 6 0 0 Ω Mo n o (Ba la n ce d)
unit to receive audio and data from the sender. Gain control can be remotely done via a PC L in e O u t Au d io L e ve l 0 d BV, 6 0 0 Ω Mo n o (Ba la n ce d)
D isto rt io n < 0 .1 % @ 0 dB
Au d io F o rm a t M P E G 1 /L a y e r 3 w i th 8 ~ 1 9 2 k bps Constant B i t R a te
N e tw o rk I n t e rf a ce R J 4 5 , 1 0 /1 0 0 M b p s E th e r n e t ( A u to ) , T C P/I P
C o n n e cto rs 1 no. Sin g le RJ45 w /L ED N e tw o rk C o n n e ct o r
1 n o . Sin g le RJ4 5 C o n n e cto r
1 n o . D o u b le D e ck RJ4 5 C o n n e cto r
1 n o . D B9 Ma le C o n n e cto r , 1 no. USB Type A Connector
VN 61A 1 n o . 2 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r
2 n o s. 4 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r
I n d ica to rs Po w e r, Prio rit y a n d At t e n u a t o r O ve rrid e
C o n tro l I n p u t 1 n o . O f D ry C o n t a ct I n p u t
C o n tro l O u t p u t 3 n o s. O f N o rm a lly O p e n D ry C o n t a ct O u t p u t ,
W ith sta n d V o lta g e 2 4 V d c, 5 m A
Atte n u a to r O ve rrid e O u t p u t 1 no. Of N o rm a lly O p e n D ry C o n t a ct O u t p u t
Technical Specifications
VN 64A
VN 64A 4 Channel Network Audio Extract
I n p u t Se n sitivity 4 Channel 0 d BV, 600 Ω Mono (Ba la n ce d)
The VN 64A extracts four stereo channel of audio from the network and convert it back to analog L in e O u t Au d io L e ve l 0 d BV, 600 Ω Mono (Ba la n ce d)
audio, ready to be fed into a power amplifier. Each channel has a unique MAC address for the F re q u e n cy Re sp o n se 2 0 H z ~ 2 0 kH z
D isto rt io n < 0 .1 % @ 0 dB
unit to receive audio and data from the sender. Gain control can be remotely done via a PC
Au d io F o rm a t M P E G 1 /L a y e r 3 w i th 8 ~ 1 9 2 k bps Constant B i t R a te
connected to the network with access rights.
N e tw o rk I n t e rf a ce R J 4 5 , 1 0 /1 0 0 M b p s E th e r n e t ( A u to ) , T C P/I P
C o n tro l I n p u t 4 n o s. O f D ry C o n t a ct I n p u t
VN 51
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
13
VECTUS VEB Series
TCP/IP Network Matrix PA System
logging and fault monitoring of all critical components within the system. Indicators Power
that are not network compliant. The unit is capable of receiving 60 opto-coupler contact VEB 31
closures which can be programmed to trigger a number of functions in the system such Network Interface 10/100 Mbps Ethernet TCP/IP
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
14
VECTUS VEB Series
TCP/IP Network Matrix PA System
that are not network compliant. The unit provides 60 opto-coupler output trigger, which VEB 32
can be used to trigger external relays and devices. Network Interface 10/100 Mbps Ethernet TCP/IP
Indicators Power
VEB 42 Emergency Paging Panel VEB 42-EM Emergency Paging Extension Panel
The Emergency Paging Panel is rack mount unit providing emergency responders/firemen personnel to conduct evacuation in any given project. Each
Emergency Paging Panel comes with a handheld microphone and user friendly robust zone selection buttons. The Emergency Paging Panel complies
with evacuation safety standards with its entire connection path to critical equipment in the system fully monitored. The Emergency Paging Panel will
primarily communicate with the entire system via the LAN, however in the event of a failure of the LAN infrastructure, the system will revert to an
analogue failsafe mode and still allow paging throughout the system. The Emergency Paging Panel comes with 24 zones selection button, should
more zone selection button be required the unit can be cascaded with the VEB 42-EM Emergency Paging Extension Panel.
Technical Specifications
VEB 42 VEB 42-EM
No. of zone selection buttons 24 nos. Push to activate buttons 24 nos. Push to activate buttons
Indicators POWER, Fault indicator, Emergency Mode activated, SIREN in progress, TALK POWER
the art touchscreen based paging console unit. It allows the VEB 43
user to operate the unit as well as select the zones via a user Network Interface RJ 45 10/100 Mbps Ethernet TCP/IP
WIFI Connectivity
friendly GUI. From the GUI the operator will be able to make
Touchscreen Dimension 10 inch
zone selection individually or in pre-defined groups based on
the client’s requirement. Being a network enabled console, the Microphone Non-removable condenser gooseneck
microphone with windshield
unit can be connected or relocated anywhere within the project
Power Requirements 12 Vdc, 2.5 A
without hassle - simply by connecting to the LAN’s datapoint. VEB 43
Future upgrade to the unit will also allow the unit to
communicate and make announcements via WIFI connection.
can utilize the Network System Manager to manage and control the routing pattern Network Interface 10/100 Mbps Ethernet TCP/IP
according to the user requirements remotely. Indicators Power, 4 nos. Input Signal and 4 nos. Line In Control
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
15
VECTUS VEB Series
TCP/IP Network Matrix PA System
analogue audio. This audio can then be then be fed into AEX SYSTEM’s range of power VEB 604-S
Audio Output Level 4-Channels of 0 dBV (600 Ω Balanced) RJ45 Connector
amplifier models. Each of the 4 channels on the unit has a unique IP address allowing
Audio Format CD Quality BGM Audio Codec
the unit to receive its own dedicated audio from desired sources available. Individual
Network Interface 10/100 Mbps Ethernet TCP/IP
gain control can be remotely controlled using the Network System Manager via the
Indicators Power, 1 no. Analog Link Indicator, 4 nos. ATT OVR
network.
Control Output 4 nos. ATT OVR (Attenuator Override) Control output
4 nos. Control Output (user programmable)
VEB 81
VEB 82
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
16
VECTUS VEB Series
TCP/IP Network Matrix PA System
VEB 83
VAC 04 Network Automatic Amplifier Changeover Unit VAC 08 Network Automatic Amplifier
VNS 16
Changeover Unit
The VAC 04 and VAC 08 Network Automatic Amplifier Changeover unit provides monitoring and surveillance of power amplifiers within a project via
the LAN. The unit is capable of monitoring up to 4 units (VAC 04) and 8 units (VAC 08) of power amplifiers for faults. Upon fault detection the unit will
automatically changeover the faulty amplifier to a standby amplifier and at the same time report the fault to the Network System Manager or Network
Paging Station.
VAC 04 VAC 08
Technical Specifications
VAC 04 VAC 08
Network Interface 10/100 Mbps Ethernet TCP/IP 10/100 Mbps Ethernet TCP/IP
No. of channels per unit 4 Channels Duty, 1 Standby 8 Channels Duty, 1 Standby
Indicators Power, 5 Bi-Colour indicators for 4 Duty and 1 Standby amplifier status Power, 9 Bi-Colour indicators for 8 Duty and 1 Standby amplifier status
12 outputs and multiple unit can be used within a project for large scale applications. Number of output 12 nos.
Access, etc. being migrated to the network, there is a high requirement for reliable and VNS 16
secure network infrastructure to support them. The 16-Port ELV Network Switch was Ports 16 nos. RJ 45 Connectors for 10 Base-T/100 Base-T;
Auto negotiated port for connecting 10/100 Base-T devices
developed to support such demands of these ELV Systems on the LAN with better
Cabling Type Unshielded twisted pair (UTP) Cat 5 or better
performance in delivering audio/video streaming along with improved performance
Indicators Power, 16 nos. Link/Activitity,
when working with broadcast packet conditions. The VNS 16 unit is a fixed configuration 16 nos. Speed (10/100 Base-T)
16 port Fast Ethernet switch and is easily scalable to suit project requirements. Standards 802.3 10 Base-T Ethernet
802.3u 100 Base-TX Fast Ethernet
VNS 16
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
17
Features
Amplifier
R3 Z3
FL Z1
R2
FL 2
R
FL 1
R Z2 Z4
FL
D
GN
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
18
Power Amplifiers
Rated Output 60 W at 100 V 150 W at 100 V 250 W at 100 V 150 W at 100 V 250 W at 100 V
Input Sensitivity MIC 1 6.3 mm Phone socket, 0 dB/-60 dB,600 Ω Balanced (with voice activated muting function and phantom power dip switch)
MIC 2 - 4 6.3 mm Phone socket, 0 dB/-60 dB, 600 Ω Balanced (with phantom power dip switch)
AUX
1 & 2 : (MA 2006, MA 2015,MA 2025)
RCA connector, -20 dB 10k Ω Stereo input
1 - 3 : (MA 2415, MA 2425)
MA 2006 / MA 2015 / MA 2025 REC OUT RCA connector, 0 dB 600 Ω unbalanced Stereo output
Zone Selection No Zone selection No Zone selection No Zone selection 4 Zone selection 4 Zone selection
DC Power Supply 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac,
50Hz, 85 W or 50Hz, 210 W or 50Hz, 355 W or 50Hz, 210 W or 50Hz, 355 W or
24 V , 2.3 A 24 V , 5.7 A 24 V , 9.4 A 24 V , 5.7 A 24 V , 9.4 A
Control 4 no. zone selection button (push to select and push to release) Talk button
Weight 0.4 kg
Rated Output Power 4 x 60 W rms 4 x 120 W rms 1 x 240 W rms 2 x 240 W rms 1 x 480 W rms 1 x 600 W rms 2 x 600 W rms 1 x 1200 W rms
Input Level 0 dB
Power Consumption 320 VA 640 VA 320 VA 640 VA 640 VA 740 VA 1480 VA 1480 VA
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
19
Control & Monitoring
Technical Specifications
AC 04S
C onne c te d Pow e r Handling Per Channel 1200 W per channel
Indic a tor s POWER, 5 Bi - Color Indicator for 4 Duty & 1 Standby Amplifier Status
AC 04S
Pow e r Re quir e me nts 2 4 Vdc ( Re gula te d) , 0.28 A
Technical Specifications
AC 08S
C onne c te d Pow e r Handling Per Channel 1200 W per channel
Indic a tor s POWER, 9 Bi - Color Indicator for 8 Duty & 1 Standby Amplifier Status
Technical Specifications
LM 08 Line Supervisory Unit LM 08
The LM 08 Line Supervisory Unit provides real-time monitoring and
Connected Power Handling Per Channel Up to 500 W rms max
surveillance for 8 loudspeaker lines, up to a distance of 1 km, monitoring for
Nos. Of Channels per Unit 8 channels
short circuits, open circuits and ground leaks. Utilising impedance checking
Connectors Power : 1 no. 2-Ways Panel Feed Through Connector
methodology, the unit allows for monitoring of branched loudspeaker network Control & Overriding Power : 1 no. 4-Ways Panel Feed Through Connector
and audio attenuator insertion with minimal setup requirements. An LCD Communication : 1 no. Double Deck RJ 45 Socket
I/O (100 V Line) : 8 nos. 4-Ways Panel Feed Through Connector
display provides a simple user-friendly interface for setup and monitoring. The
Priority & Volume Overriding : 8 nos. 4-Ways Panel Feed Through Connector
unit is capable of interfacing with other equipment via RS 485 for remote
Control Selection Button (Enter, Clear, Up, Down, Left, Right)
monitoring, fault event logging and fault notification.
Control Output Withstand Voltage 24 Vdc 40 mA (Fault Trigger)
Withstand Voltage 24 Vdc 1 A (Attenuator Override Output)
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
20
Control & Monitoring
monitoring of the output from the power amplifier, designed for 100V line Control Source Selector : 10 interlocking switches with
mechanical indicator buttons
distributed speaker system. The AM 10S allows the selection of any one of up to Audio Control : Stepless volume control
10 power amplifier outputs to be monitored.Visual indication is provided by a VU
Input Voltage 100 V ; 5 kΩ
meter that indicates the output level of the power amplifier. Aural monitoring is
provided by a high quality dynamic full range loudspeaker built into the enclosure Loudspeaker Component Dynamic Full Range Loudspeaker
of the unit. It is 19” EIA standard rack mountable and only takes up 1U space.
Level Meter Analog VU Meter
Weight 2.1 kg
AM 10S
against short circuit and overloading.There is a provision in the PS 06 to allow for Output 24 Vdc (Regulated), 6A max
connection to an array of batteries for backup power supply, in the event of AC
Regulation +/- 0.5 Vdc, 0.1 V ripple max.
power failure, the battery power automatically switches to supply the equipments
connected to the power supply unit. Protection Solid state & fast blow glass tube fuse
DC Fuse Rating : 6A, Short
AC Fuse Rating : 2A, Short
The LS 12A also comes with an additional ALL CALL button which automatically Indicator Type Green LED indicator for each zone
selects all 12 zones on the unit for added convenience. Control Input Dry contact transistor closure
Technical Specifications
AP 01 AT 06S AT 30S AT 60S AT 120S
Maximum Power 120W (100V) 6W (100V); 3W (70V) 30W (100V); 15W (70V) 60W (100V); 30W (70V) 120W (100V); 60W (70V)
Attenuation 5 level of -6 dB per step 5 level of -6 dB per step 5 level of -6 dB per step 5 level of -6 dB per step
(0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB,
-18 dB, - dB) -18 dB, - dB) -18 dB, - dB) -18 dB, - dB)
8
8
8
Material & Finish ABS Resin, White ABS Resin, White ABS Resin, White ABS Resin, White ABS Resin, White
Emergency Override 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
21
Loudspeakers
transformer is built into the unit, suitable for use with 100V line systems. Sensitivity 92 / 100 dB 90 / 98 dB
( 1 W / rated at 1m )
Coverage Angle 180 ° 180 °
( 1 kHz, -6 dB )
Frequency Response 100 Hz ~ 20 kHz 110 Hz ~ 20 kHz
CA 563 CA 564E Speaker Component 120 mm Dynamic Full 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker
as supermarkets, offices and restaurants, reproducing voice announcements and CE 565 CE 565E
background music with high clarity. Mounted on to a high impact ABS grille with an Rated Input (100 V) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W )
70 V : 3 W ( 3 - 1.5 - 0.75 W ) 70 V : 3 W ( 3 - 1.5 - 0.75 W )
off-white finish, its 120 mm dynamic full range loudspeaker component reproduces
Maximum Power 9W 9W
the source signal with high intelligibility due to its extended frequency response. An
Rated Impedance 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ )
aesthetically pleasing front metal mesh comes as a standard feature. Both models
are spring mounted on to the ceiling for ease of installation. They come with a Sensitivity
(1W / rated at 1m)
90 / 98 dB 90 / 98 dB
multiple impedance line matching transformer, suitable for 70 V or 100 V distributed Coverage Angle 180 ° 180 °
loudspeaker system with a maximum power handling of 6 W rated at 100 V. Model (1 kHz, -6 dB)
CE 565E comes readily fitted with a metal back enclosure to prevent fire from Frequency Response 110 Hz ~ 20 kHz 110 Hz ~ 20 kHz
speading via the ceiling cavity. Speaker Component 120 mm Dynamic Full 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker
Rated Input (100 V) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 10 W ( 10 - 5 - 2.5 W ) 100 V : 10 W ( 10 - 5 - 2.5 W )
70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 5 W ( 5 - 2.5 - 1.3 W ) 70 V : 5 W ( 5 - 2.5 - 1.3 W )
Maximum Power 9W 9W 9W 9W 15 W 15 W
Rated Impedance 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 1 kΩ ( 1 - 2 - 4 kΩ ) 1 kΩ ( 1 - 2 - 4 kΩ )
Coverage Angle (1 kHz, -6 dB) 180 ° 180 ° 180 ° 180 ° 180 ° 180 °
Frequency Response 64 Hz ~ 20 kHz 64 Hz ~ 20 kHz 100 Hz ~ 20 kHz 115 Hz ~ 20 kHz 64 Hz ~ 20 kHz 100 Hz ~ 20 kHz
Speaker Component 75 mm Dynamic Full 100 mm Dynamic Full 100 mm Dynamic 130 mm Dynamic Full 160 mm Dynamic Full 160 mm Dynamic Full
Range Loudspeaker Range Loudspeaker Full Range Loudspeaker Range Loudspeaker Range Loudspeaker Range Loudspeaker
Safety Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
22
Loudspeakers
time without the need of visible screws. CS 332 come with a multiple impedance Sensitivity 88 / 96 dB 88 / 96 dB
(1W / rated at 1m)
line matching transformer, suitable for 70V or 100V distributed loudspeaker
Coverage Angle 180 ° 180 °
system with a maximum power handling of 6W rated at 100V. All models come with (1 kHz, -6 dB)
back enclosure to prevent crosstalk between adjacent zones via the ceiling void. Frequency Response 250 Hz ~ 20 kHz 250 Hz ~ 20 kHz
Rated Input 100 V : 10 W (10 - 5 - 2.5 W) 100 V : 10 W (10 - 5 - 2.5 W) 100 V : 15 W (15 - 7.5 - 3.8 W) 100 V : 15 W (15 - 7.5 - 3.8 W)
70 V : 5 W (5 - 2.5 - 1.3 W) 70 V : 5 W (5 - 2.5 - 1.3 W) 70 V : 7.5 W (7.5 - 3.8 - 1.9 W) 70 V : 7.5 W (7.5 - 3.8 - 1.9 W)
Rated Impedance 1 kΩ (1 - 2 - 4 kΩ) 1 kΩ (1 - 2 - 4 kΩ) 670 Ω (670 - 1330 - 2670 Ω) 670 Ω (670 - 1330 - 2670 Ω)
Speaker Component 160 mm 2-Way Coaxial Loudspeaker 160 mm 2-Way Coaxial Loudspeaker 200 mm 2-Way Coaxial Loudspeaker 200 mm 2-Way Coaxial Loudspeaker
Rated Impedance 330 Ω (330 - 670 - 1330 kΩ) 330 Ω (330 - 670 - 1330 kΩ) 8Ω
Speaker Component LF : 1 no. 120 mm Dynamic Full LF : 1 no. 120 mm Dynamic Full LF : 1 no. 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker Range Loudspeaker
HF : 25 mm Neodymium HF : 25 mm Neodymium HF : 25 mm Neodymium
Magnet Dome Tweeter Magnet Dome Tweeter Magnet Dome Tweeter
FG 530W
FG 530WL Safety Acc. to EN 60065 Acc. to EN 6006 5 Acc. to EN 60065
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
23
Loudspeakers
enclosure to withstand harsh outdoor weather conditions, rated to Speaker Component 120 mm Dual cone loudspeaker component,
waterproof treated
IP X4. The unit comes with a built-in audio line matching GD 6
Protection IPX4 (acc. to IEC 529)
transformer for both 100V/70V line distributed speaker systems,
Safety Acc. to EN 60065
rated at 30W.
M a te r ia l & Finish High Impact Polystyrene (HIPS), Mint Green
Technical Specifications
PD 506W PD 506B PD 512W PD 512B
Maximum Power 9W 9W 18 W 18 W
Rated Impedance 1.7 kΩ (1.7 – 3.3 kΩ) 1.7 kΩ (1.7 – 3.3 kΩ) 0.83 kΩ (0.83 – 1.7 kΩ) 0.83 kΩ (0.83 – 1.7 kΩ)
Frequency Response 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz
Speaker Component 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker
Material & Finish ABS; White ABS; Black ABS; White ABS; Black
and water protected to IP 65 (IEC 529), thus ideal for Coverage Angle 165° 160°
(1 kHz, -6 dB)
outdoor applications with harsh environmental
Frequency Response 280 Hz ~ 12.5 kHz 250 Hz ~ 10 kHz
conditions. Available in two different models, the
Safety Acc. to EN 60065 Acc. to EN 60065
models are transformerised for 70V/100V line
Dust & Water Protection IP65 (acc. to IEC 529) IP65 (acc. to IEC 529)
distributed speaker system and comes with a swivel
RH 113 mounting bracket for final positioning adjustment.
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
24
Loudspeakers
Speaker Component 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker
Rated Input (70 V) 7.5 W (7.5 - 3.8 - 1.9 W) 15 W (15 - 7.5 - 3.8 W) 25 W (25 - 12.5 - 6.3 W)
Rated Impedance 670 Ω (670 - 1330 - 2700 Ω) 330 Ω (330 - 670 - 1330 Ω) 200 Ω (200 - 400 - 800 Ω)
Distribution Pattern 164˚ (H) x 87˚ (V) 155˚ (H) x 64˚ (V) 186˚ (H) x 46˚ (V)
Speaker Component 2 nos. 100 mm Full Range 4 nos. 10 mm Full Range 6 nos. 100 mm Full Range
Dust & Water Protection IP65 (acc. to IEC 529) IP65 (acc. to IEC 529) IP65 (acc. to IEC 529)
- Only for VA 415W - Only for VA 430W - Only for VA 450W
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
25
Loudspeakers
Technical Specifications
WM 563 WM 512
Rated Input 100V : 6 W (6 - 3 - 1.5 W) 100V : 12 W (12 - 6 - 3 W)
WM 563 70V : 3 W (3 - 1.5 - 0.75 W) 70V : 6 W (6 - 3 - 1.5 W)
Maximum Power 9W 18 W
Rated Impedance 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 0.83 kΩ (0.83 - 1.7 - 3.3 kΩ)
Sensitivity 90 / 98 dB 93 / 104 dB
(1W / rated at 1 m)
Coverage Angle 70 ° 70 °
(1 kHz, -6 dB)
Technical Specifications
WM 561W
Sensitivity 93 / 101 dB
WM 561W (1 W / rated at 1m)
Coverage Angle (1 kHz, -6 dB) 106 °
www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
26
PO - 015 - 01 Technical Alterations Reserved