Product Overview

2015 / 2016
Input Sources

ME 1, MH 1a, MH 2a Emergency and Handheld Microphone


The ME 1 is an emergency handheld type unidirectional dynamic microphone which is activated by a press to talk switch. The microphone unit
provides a trigger to the receiving equipment with priority functions. The MH Series handheld microphone consist of MH 1a with a cardioid polar
pattern for general use and MH 2a (Supercardioid) for better noise rejection and wide bandwidth for professional applications. Both models feature
excellent handling noise with its advanced shock-mount system and robust die-casted zinc alloy body with a hardened ball mesh to protect its
capsule. Performance is further improved with its noise-free slide switch for unobtrusive operation.
Technical Specifications
MH 1a MH 2a ME 1

Type Dynamic microphone Dynamic microphone Dynamic microphone

Polar Pattern Unidirectional, Cardioid Unidirectional, Super Cardioid Unidirectional

Frequency Response 50 Hz ~ 15 kHz 50 Hz ~ 16 kHz 300 Hz ~ 8 kHz

Output Impedance 600 Ω (Unbalanced at 1 kHz) 600 Ω (Unbalanced at 1 kHz) 600 Ω (Unbalanced at 1 kHz)

Output Level -72 dB +/- 3 dB (at 1 kHz) -72 dB +/- 3 dB (at 1 kHz) -72 dB +/- 3 dB (at 1 kHz)

Magnet Type Neodymium Neodymium Ferrite


MH 1a MH 2a ME 1
Capsule Type 29 mm Dynamic Moving Coil 29 mm Dynamic Moving Coil 24 mm Dynamic Moving Coil

Cable 5 m Microphone Cable 5 m Microphone Cable Coiled cable,


(3 pin XLR (F) (3 pin XLR (F) 3 cole & 1 screen x
to 1/4” mono Phone Jack) to 1/4” mono Phone Jack) 1.4 m (at a max extended length)

Switch Slide switch (Pop-Free) Slide switch (Pop-Free) Push-to-talk switch

Dimensions Dia 53 x 180 mm Dia 53 x 185 mm 58 x 80 mm

Material & Finish Diecasted zinc alloy Diecasted zinc alloy ABS. matt black & grey
with steelmesh. with steelmesh.
metallic quartz grey/silver metallic quartz grey/silver

DS 201-S Digital Source Player


The DS 201-S Digital Source Player is a dual purpose player capable of providing pre-stored MP3 messages as well as serving as a
Background Music (BGM) source for any Public Address (PA) System application. The DS 201-S utilizes an SD Card as its primary
storage and also monitors the availability of the SD Card for faults. The unit allows 12 MP3 messages to be pre-stored and the
messages can be selected to play via the front panel message selector button or via dry contact from the rear terminal connector.

The unit features a Background Music (BGM) mode which when triggered allows the user to play all the pre-stored music files in the
SD Card. The unit is suitable for applications in factory environments where its easily accessible messages can triggered to signify
end/start of shifts, in shopping malls and hotel environment where it can serve as a BGM source with thousands of music files to
enhance the ambient environment. The DS 201-S can also be integrated with the fire alarm panel, providing automatic evacuation or
warning messages in the event of an emergency.
Technical Specifications
DS 201-S

Output Channels 1nos. Stereo Output (RCA Connector)


1nos. 0dB Balanced Output (RJ 45)

Storage Medium SD Card (Supports SDHC Card)

Control Input 14 Control Inputs (12-Message select, BGM Play, Stop)

Control Output 1nos. Message in progress Control Output Dry Contact


(Max. current handling 24Vdc, 3A)
1nos. Bell Muting Control Opto-Coupler Control output

Frequency Response 20Hz ~ 20kHz

Power Requirement 24 Vdc (Regulated), 0.3A

Dimensions (W x H x D) 483 x 44 x 150 mm

Material and Finish Mild Steel; Epoxy Powder


Coated Textured Black

Weight 2.2 kg

MC 3, MP 2 Desktop Microphone
Technical Specifications
The MC 3, and MP 2 are Desktop Microphones range MC 3 MP 2
which promote simplicity and exceptional quality. The MC Connector 6.3 mm phone socket 6.3 mm phone socket
3 ( 0 dB output ) features an ascending and descending 2 nos. 2 way panel feed through 1 no. 2 way panel feed through
connector connector
4-tone chime. Dual-colour LED indicators clearly display
Indicator Type Chime in progress / Talk indicator
paging status while the entire unit are aesthetically
designed. Audio Signal Output 0 dBV, 600 Ω (Balanced) -60 dBV, 500 Ω (Balanced)

Frequency Response 100 Hz ~ 12 kHz 100 Hz ~ 12 kHz

Dimensions (W x H x D) 105 x 50 x 170 mm 105 x 50 x 170 mm


MC 3 MP 2
Power Requirement 24 Vdc (Regulated), 0.1 A Phantom Power

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
01
MEDUSA 3
Integrated PA System

MEDUSA 3 Integrated PA System


MED 306M - 600W Integrated PA System Master Unit
MED 312M - 1200W Integrated PA System Master Unit
MED 306S - 600W Integrated PA System Slave Unit

The Medusa 3 Series was developed with a clear objective, a Public Address System that was reliable and easy to use. A single box solution
suitable for virtually any small-to-medium scale Public Address system application. The Medusa 3 Series consist of the Master Unit with a built in
power amplifier making it an extremely easy to deploy standalone PA System.

The Master unit is also versatile and provides up to 12-zones coverage. The Master Unit can be expanded with a Slave Unit, increasing the
systems amplification power as well as zones up to a maximum of 24-zones. The Medusa 3 Series can be complimented with a Medusa MEI 60
Automatic Evacuation Interface, allowing for a fully automated ‘sandwich’ (N+1, N, N-1) evacuation with built in message.

The Medusa 3 also comes with a built in amplifier monitoring and automatic changeover circuit to switch over the internal Master or Slave power
amplifier to an external standby amplifier upon failure. Coupled with a built-in siren and handheld emergency microphone the Medusa 3 Series
satisfies the growing need for building evacuation systems.

MED 306M MED 312M MED 306S

Technical Specifications
MED 306M MED 312M MED 306S

Rated Power Output 600 W at 100 V line 1200 W at 100 V line 600 W at 100 V line

Output Zones 12 Zone 12 Zone 12 Zone

Frequency Response 20 Hz - 20 Khz 20 Hz - 20 Khz 20 Hz - 20 Khz

Input Sensitivity
Remote Mic 0 dB Balanced 0 dB Balanced
Line 1 0 dB Balanced 0 dB Balanced
AUX 1 - 3 RCA Connector, -20 dB Stereo RCA Connector, -20 dB Stereo

REC OUT 0 dB Balanced 0 dB Balanced

Amplifier Changeover Built - In Built - In Built - In

Protection Circuit Over current & short circuit protection Over current & short circuit protection Over current & short circuit protection
with resettable fuse with resettable fuse with resettable fuse

Power Requirement 220 ~ 240 Vac, 50/60 Hz, 853W 220 ~ 240 Vac, 50/60 Hz, 1706W 220 ~ 240 Vac, 50/60 Hz, 853W
or 24 Vdc, 22.9 A or 24 Vdc, 44.8 A or 24 Vdc, 22.9 A

Dimensions (W x H x D) 430 x 132 x 500 mm 430 x 132 x 500 mm 430 x 132 x 500 mm

Weight 26 kg 39 kg 26 kg

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
02
MEDUSA 4
Integrated Signal Manager

MEDUSA 4
MED 400P Integrated Signal Manager
The Medusa 400P Integrated Signal Manager is a versatile public address pre-amplifier unit based on the key features of the Medusa 3
Series. The Medusa 400P Integrated Signal Manager comes with a built-in 12 zone line selector and is scalable with external LS 12A
Speaker Line Selector for a maximum of 60 zones.

The Medusa 400P is designed to be used with external power amplifiers making it a highly scalable suitable for any medium - to - large
scale projects. The Medusa 400P can be supplemented by a host of AEX System products such as automatic amplifier changeover unit,
Medusa Automatic Evacuation Interface and Remote Microphones.

Technical Specifications

MED 400P

Output Zones 12 Zone

Frequency Response 20 Hz - 20 Khz

Input Sensitivity
Remote Mic 0 dB Balanced

Line 1 0 dB Balanced
MED 400P AUX 1 - 3 RCA Connector, -20 dB Stereo

REC OUT 0 dB Balanced

Protection Circuit Over current & short circuit protection


with resettable fuse

Power Requirement 24 Vdc, 0.5 A

Dimensions (W x H x D) 430 x 87 x 200 mm

Weight 5.0 kg

MEI 60 Automatic Evacuation Interface


Technical Specifications
The MEI 60 Automatic Evacuation Interface is designed to be used
MEI 60
with the MEDUSA 3 and MEDUSA 400P range of products. The unit
is designed to be integrated with the fire alarm panel and conduct Connector RJ45 for communication.
Panel feedthrough connector.
automated evacuation upon triggered.
No. of Dry Contact 60

The unit has internal storage for evacuation messages and can be
Power Requirement 24 Vdc, 0.4 A
configured to conduct (N+1, N, N-1) sandwich evacuation
procedure or a simple ALL CALL total evacuation. The unit is Dimensions (W x H x D) 430 x 150 x 44 mm
features 60 dry contact inputs.
Weight 1.8 kg

MEI 60

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
03
MEDUSA 5
Public Address & Emergency Voice Alarm Control System

MEDUSA 5
Public Address & Emergency Voice Alarm Control System

The MEDUSA Series is designed with a clear objective, to reduce


equipment count, ease installation and reduce inter-equipment
cabling by integration of multi-functions into a single box. A single
box solution shortens installation time and reduces the possibility of
errors.
The MEDUSA Series consist of the main unit that performs the audio
pre-amplification, signal routing, remote microphone management,
automated voice alarm with fire alarm interface, system configuration
& monitoring, power amplification & amplifier monitoring and line
supervisory. The unit also comes with a built-in Digital Message
With the growing needs of building evacuation systems, integrated Player and Time Scheduler which is programmable via a Windows
with paging and uninterrupted background music capabilities, the based GUI provided. The expansion of zones are supported by the
MEDUSA Series offer a cost-vs-performance solution to any use of the Active Routers. The maximum number of zones
installation with unsurpassed features that is only found in high-end configurable with the MEDUSA Series is 126 zones.
systems.

Technical Specifications
MEDUSA 54 (with built-in 480W power amplifier)
MEDUSA 52 MEDUSA 54
MEDUSA 52 (with built-in 240W power amplifier) Rated Output Power 240 W 480 W
Voice Alarm Controller Frequency response (at rated output) 40 Hz to 18 kHz
Output and load impedance 100 V (42Ω) 100 V (21Ω)
Signal-to-Noise Ratio Better than 80 dB
The MEDUSA 5 provides audio pre-amplification, signal routing, Total Harmonic Distortion < 0.5% (at rated output, f=1 khz)
remote microphone management, automated voice alarm with fire Input Sensitivity
alarm interface, system configuration & monitoring, power AUX 1 -20 dBv (20 kΩ Unbalanced) RCA Connector
AUX 2 -20 dBv (20 kΩ Unbalanced) RCA Connector
amplification & amplifier monitoring. The MEDUSA 5 is suitable for
AUX 3 -20 dBv (20 kΩ Unbalanced) RCA Connector
systems that requires a straight-forward automated voice alarm LINE IN -60/0 dBv (10kΩ Balanced) RJ45 Connector
function. Remote Microphone Input 0 dBv (600 Ω Unbalanced) RJ45 Connector
Output
LINE OUT 0 dBv (100 Ω Balanced) RCA
REC OUT 0 dBv (100 Ω Stereo) RCA
MAR 0 dBv (600 Ω Stereo) RJ45
External Amplifier 0 dBv (600 Ω Stereo) RJ45
Communication control
R-COMM RJ45
USB Connection USB 2.0, Type B
Dry Contact Control
Control Input (1-6) Control Input
Time Scheduler Control Output
MEDUSA 52 / 54
Fault Control Output
Emergency Override Control Output
Amplifier Changeover Built - In
Power Requirements 220 - 240 Vac, 50 Hz
Power Consumption 343 VA 686 VA
Backup Battery Power Requirements 220 ~ 240 Vac, 50 Hz, 352 W 220 ~ 240 Vac, 50 Hz, 704 W
or 24Vdc, 15 A or 24Vdc, 25 A

MAR 12 Active Router (12 zone)


MAR 24 Active Router (24 zone)
The MAR 12 / MAR 24 Active Routers provide additional zone control
to MEDUSA 5. They comes with built-in amplifier monitoring &
changeover functions.
MAR 12
Technical Specifications
MAR 12 MAR 24
Power Requirement 24 Vdc (Regulated) , 0.4 A 24 Vdc (Regulated), 0.5 A

Power Consumption 12 W 24 W

Connector RJ 45 RJ 45

Max. Current Flow max. output 500W, 5A max. output 500W, 5A

Switches 12 push to activate buttons 24 push to activate buttons


MAR 24

Amplifier Input 2 BGM, 2 paging stations 4 BGM, 4 paging stations

Output Zones 12 24

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
04
MEDUSA 5
Public Address & Emergency Voice Alarm Control System

VM 12 Multi-System Network Manager


VM 21S Network Paging Station
VM 22S Multi-System Network Paging Station
VM 31 Station Adaptor
The VM 12 provides the node address configuration and centralized
time-scheduling for multiple PA Systems integrated over the
network. The VM 21S/VM 22S transforms any desktop PC to a
powerful PA paging terminal with Windows based graphical paging
interface, time scheduling for pre-recorded message broadcast and
text streaming where text input is synthesised into human voice for
consistent voice announcements. The VM 21S/VM 22S enables the
VM 12 / VM 21S / VM 22S
MEDUSA to receive and make announcements over the LAN,
WAN and internet. VM 31 serves as an audio pre-amp unit for
VM 31
VM 21S/VM 22S to the conventional PA System Line Input .

MAI 60 Alarm Interface Unit


MAI 60EM Alarm Interface Unit Extension Module
The MAI 60 provides up to 60 nos. of control input for external
interface to other systems such as the Fire Alarm System. The unit MAI 60

comes with 15 nos. of control input and 3 slots for extension


modules of 15 control input each. A maximum of two units can be
connected to the MEDUSA system, bring a total of 126 control MAI 60EM
inputs.

Technical Specifications Technical Specifications


MAI 60 MAI 60EM
Power Requirement 24 Vdc (Regulated) , 0.06 A Power Requirement Supply form MAI 60

Power Consumption 12 W Connector RJ 45


16 way panel feed through connector
Connector RJ 45
16 way panel feed through connector No. of Dry Connect 15 nos.

No. of Dry Connect 15 nos.

MRM 06 Remote Microphone


The MRM 06 Remote Microphone provides 6 loudspeaker zone selection button with ALL
CALL, ALL CLEAR and TALK button. LED indicator for chime in progress and ready-to-talk
assists the operation of the unit. A BUSY indicator lights when another microphone with
higher priority is in use. The remote microphone connects to the MEDUSA controller
through a single RJ-45 plug and communicates serially up to 1 km. The system is able to
handle up to 8 microphones. The unit comes with a supervisory circuit for fault detection of
the unit itself and the communication line.
Technical Specifications
MRM 06

Remote Microphone Input Sensitivity 0 dBV

Frequency Response 100 Hz – 16 kHz

Switches 9 Individual Group Switches,

Maximum Cable Length 1000 meter(Shielded Cable)


MRM 06
Power Requirement 24 Vdc (Regulated) , 0.16 A

Power Consumption 4 W

Connector RJ 45

MRE 12 Remote Microphone Extension


The MRE 12 Remote Microphone Extension provides an additional 12 loudspeaker zone
control. The MEDUSA system is extendable up to a maximum of 126 zones. The unit
connects to the main microphone unit for power and communication.

Technical Specifications
MRE 12
Switches 12 Individual Group Switches,

Power Requirement 24 Vdc (Regulated), 0.12 A


MRE 12
Power Consumption 3W

Connector RJ 45

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
05
eMatrix

Series Digital Matrix System


The eX 800A Series eMatrix System is an 8-bus Digital Audio matrix, designed to
fulfil the demands for both emergency and communication broadcasting, operating Specification

normally as a Public Address Management System and transforming into an


Emergency Management System during emergency. eX 800A Series consists of
Basic Early Evacuation System. The eX 800A Series is able to handle up to a
maximum of 20 inputs while providing a maximum of 60 pure audio outputs which
are fully expandable to 188 speaker zones using relays. The eMatrix System is able
to handle up to 8 simultaneous inputs and 60 simultaneous outputs.

eX 801A Single CPC Main Frame Technical Specifications


eX 801A
The eX 801A houses up to ten module cards and provides them with audio and data buses
Power Requirement 24 Vdc (Regulated), 1.5 A
while distributing the incoming power supply. The eX 801A controls and monitors all operation
No. of Central Processing Card 1 no. eX 821A
with integrated front facial indicators for the status of the system such as Power, CPU Off,
Error and System Status. The main frame also transmits audio and data informations to the No. of Power Supply Inlet Card 1 no. eX 881A

extension frame for additional module cards. No. of Card Slot per Frame 10

Indication Power, CPU Off, Error, Status 1

eX 802A Dual CPC Main Frame Technical Specifications

The eX 802A has all the features found in the eX 801A except that it houses an additional eX 802A

Standby Central Processing Card (CPC) which automatically takes over the operation of the Power Requirement 24 Vdc (Regulated), 1.5 A

Main CPC in the event of a fault. This feature avoids operational down time and eliminates the No. of Central Processing Card 1 no. eX 821A, 1 no of eX 822A

need to have a fully redundant system as a backup which is much costlier and difficult to No. of Power Supply Inlet Card 1 no. eX 881A
maintain. No. of Card Slot per Frame 9

Indication Power, CPU Off Error, Status 1, Status 2

eX 803A Extension Frame Technical Specifications

eX 803A
The Extension Frame is used when additional modules cards are needed to cater for a more
Power Requirement 24 Vdc (Regulated), 1.5 A
extensive public address system. An audio & data bus connects the main frame to the
extension frame. The eX 803A features ten card slots, Extension Card, Power Supply Inlet No. of Extension Card 1 no. eX 824A

Card and a front facial Power Indicator. No. of Power Supply Inlet Card 1 no. eX 881A
No. of Card Slot per Frame
10

Indication Power

eX 811A Control Manager


The eX 811A Control Manager is the proprietary software which is exclusively integrated with the eX 800A
Series to enable the user to configure and customize the eMatrix System to suite its application. It allows user
to configure input channel, output zones, time scheduler, failure output patterns, system diagnosis settings
and many other functions. The Control Manager supports up to 3500 event logs, which records the system’s
activities and faults. Moreover, the software enables the user to perform tests to check the status of audio
path, hardware cards and so on. It also provides a constant monitoring system so that the eMatrix System is
in optimum working condition. For security reason, the software provides 3-level password protection and any
login will automatically be detected by the software when the password is entered.

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
06
eMatrix

eX 821A Central Processing Card Technical Specifications

The eX 821A coordinates the activities of the module cards and eX 821A

performs the automated simultaneous voice evacuation during Connector 1 No. RJ45 Connector
1 No. DB9 Male Connector
emergency. The card has a built-in Real Time Clock, CPU fault 1 No. DB9 Female Connector

detection circuit and it is also able to communicate with the other Power Requirement Supplied by Main / Extension Frame

range of firemen interface equipments by AEX System.

eX 822A Central Processing Card 2


The eX 822A works as a hot-standby Central Processing Card (CPC) Technical Specifications
for the eX 821A. The module slots into a dedicated slot in the eX 802A eX 822A
Dual CPC Main Frame and monitors the operation of the primary Connector 1 No. RJ45 Connector;
CPC. In the event of failure to the primary CPC, the secondary CPC 1 No. DB9 Female Connector

will automatically take over the entire operation. The switchover is Power Requirement Supplied by Main / Extension Frame

instantaneous while an audible warning is emitted in the event of


failure for rectification work. Every event is logged for reporting and
available for print-out from the GUI.

eX 823A Main Frame Extension Card eX 824A Extension Frame Extension Card

This card provides output terminals to extend the This card receives audio and data signals from the eX
audio and data buses from the main frame to the 823A and extends them to the modules housed in the
additional modules housed in the extension frame. extension frame. It also extends the audio and data buses
from the extension frame to the next extension frame.
Technical Specifications

eX 823A
Technical Specifications
Connector 4 Nos. RJ45 Connector
eX 824A
Power Requirement Supplied by Main / Extension Frame
Connector 8 nos. RJ45 Connector

Power Requirement Supplied by Main / Extension Frame

Technical Specifications
eX 831A

No. of Channel 2

Input Sensitivity MIC: -70 to -45 dB (Adjustable)


eX 831A Auxiliary Input Card with built in Audio Limiter,
600 Ω (Unbalanced)
LINE: -20 to + 8 dB (Adjustable),
The eX 831A provides two auxiliary inputs for sources such as 10 kΩ, balanced MIC or
background music, digital messages and microphones with jumper LINE selectable by the built-in jumper

settings for a wide range of input levels and individual gain Low Frequency Filter (100 Hz) -15 dB to + 15 dB Boost & Cut (Adjustable)
potentiometer. The card can also provide phantom power to a -15 dB to + 15 dB Boost & Cut (Adjustable)
Distortion
condenser microphone if required. High Frequency Filter (10 kHz) < 0.5%

Frequency Response 20 Hz - 20 kHz

Phantom Power 7.5 V

Control Input Dry Contact Activation

2 nos. Volume Control


Control
Connector 2 nos. RJ45 Connector

Power Requirement Supplied by Main / Extension Frame

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
07
eMatrix

eX 834A Microphone Input Card


Technical Specifications
The eX 834A provides two inputs for the eX 800A Series: eX 834A
Microphones. Each input is able to communicate up to eight No. of Channel 2

Remote Microphones or a combination of four Emergency Connectable eX 861A, eX 862A, eX 863A, eX 864A
Microphones and four Remote Microphones. Microphone eX 865A, eX 866A, eX 867A, eX 868A

Connector 2 nos. RJ45 Connector

Power Requirement Supplied by Main / Extension Frame

Technical Specifications
eX 836A Audio Output Card eX 836A

The eX 836A provides two 0 dB electronically balanced audio No. of Channel 2

outputs with individual gain control via the Control Manager Output Level & Impedance 0 dBV, 600 Ω (Balanced)
software. A dry contact output is available to provide external Control Output NO or NC Dry Contact (max. 24 Vdc, 1 A)
control which can be used for overriding the audio attenuator
Connector 2 nos. RJ45 Connector;
when the channel is activated. The module either connects 1 no. 1 x 4-pin Panel Feed
Through Connector
directly to the power amplifier inputs or through the automatic
amplifier changeover unit for amplifier changeover purposes. Power Requirement Supplied by Main / Extension Frame

Technical Specifications
eX 841A

No. of Channel 16
eX 841A Control Input Card
Sensing Method Dry Contact or Current Loop
The eX 841A provides up to 16 opto-isolated control sensor ( jumper selectable )

inputs to receive external dry contact signals which will be Dry Contact Method NO
transmitted to the Central Processing Unit to perform the next Current Loop Method Released Voltage 24 Vdc, 5 mA
instruction.
Connector 4 nos. RJ45 connector

Power Requirement Supplied by Main / Extension Frame

Technical Specifications
eX 842A
eX 842A Control Output Card
No. of Channel 16
The eX 842A Control Output Card provides up to 16 Triggering Method NO or NC Dry Contact
( jumper selectable )
make/break relay dry contact output signals to any external
system. Each contact is able to withstand a voltage of up to Withstand Voltage 24 Vdc, 250 mA

24 Vdc, 250 mA. Connector 4 nos. RJ45 Connector

Power Requirement Supplied by Main / Extension Frame

eX 874A Blank Panel eX 881A Power Supply Inlet Card


The blank panel is used to cover any unused The eX 881A Power Supply Inlet Card accepts
slots in the frame to prevent foreign objects from regulated 24 Vdc power supply through its 3 pin
entering the enclosure. terminal block, which includes an earth
termination.

Technical Specifications Technical Specifications


eX 874A eX 881A

Material & Finish Mild Steel; Epoxy Coated Power Handling Supplied by Main / Extension Frame

Dimension ( W x H x D ) 35.5 x 128 x 5 mm Connector 1 No. 3-Pin Terminal Block,

Weight 20 g Material & Finish Mild Steel; Exopy Coated Black

Dimension ( W x H x D ) 19.5 x 128 x 173 mm

Weight 100 g

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
08
eMatrix

eX 861A . eX 862A . eX 863A . eX 864A Emergency Microphone


The Emergency Microphones are equipped with programmable function keys to perform zone selection, group selection and matrix
functions. The models comes with an Emergency Confirm and a Cancel button with latched covers. The units are connected to the
main system, via RS 485 up to 1.2 km. All models feature built-in chime, audio gain control and 20 kHz pilot signal. An auto mic off
feature monitors the microphone for inactivity and automatically shuts it off to prevent the unit from occupying the system.

Technical Specifications

Item eX 861A eX 862A eX 863A eX 864A

Output Level & Impedance 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced

Gooseneck Microphone Unidirectional electret Unidirectional electret Unidirectional electret Unidirectional electret
conderser microphone conderser microphone conderser microphone conderser microphone

Distortion <1% <1% <1% <1%


eX 861A
Frequency Response 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz

Signal-to-Noise Ratio > 60 dB > 60 dB > 60 dB > 60 dB

Internal Monitor Speaker 0.5 W 0.5 W 0.5 W 0.5 W

Volume Control Microphone Level Microphone Level Microphone Level Microphone Level eX 862A
Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker
Level Control, Siren Level Control, Siren Level Control, Siren Level Control, Siren
Level Control Level Control Level Control Level Control

Auto Mic OFF 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min.

Number of Programmable Functions 10 20 40 120

Number of Connectable Units 4 4 4 4

Communication Protocol RS 485 RS 485 RS 485 RS 485


eX 863A
Connector RJ45, RJ45, RJ45, RJ45,
panel feed through connector panel feed through connector panel feed through connector panel feed through connector

Communication Distance 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable)

Power Requirement 24 Vdc (Regulated), 0.18 A 24 Vdc (Regulated), 0.2 A 24 Vdc (Regulated), 0.2 A 24 Vdc (Regulated), 0.32 A
eX 864A
Material & Finish ABS Resin & Aluminium, Epoxy Coated Black

Dimension ( W x H x D ) 265 x 64.5 x 185 mm 265 x 64.5 x 185 mm 265 x 64.5 x 185 mm 475 x 64.5 x 185 mm

Weight 1.3 kg 1.3 kg 1.3 kg 2.0 kg

eX 865A . eX 866A . eX 867A . eX 868A Remote Microphone


The Remote Microphones are equipped with programmable function keys to perform zone selection, group selection and matrix functions.
The units are connected to the main system via RS 485 up to 1.2 km. All models feature built-in chime, audio gain control and 20 kHz pilot
signal for audio path diagnosis. An auto mic off feature monitors the microphone for inactivity and automatically shuts it off to prevent the
unit from occupying the system.

Technical Specifications

Item eX 865A eX 866A eX 867A eX 868A

Output Level & Impedance 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced 0 dBV 600 Balanced

Gooseneck Microphone Unidirectional electret Unidirectional electret Unidirectional electret Unidirectional electret
conderser microphone conderser microphone conderser microphone conderser microphone

Distortion <1% <1% <1% <1%

Frequency Response 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz 100 Hz - 20 kHz
eX 865A
Signal-to-Noise Ratio > 60 dB > 60 dB > 60 dB > 60 dB

Internal Monitor Speaker 0.5 W 0.5 W 0.5 W 0.5 W

Volume Control Microphone Level Microphone Level Microphone Level Microphone Level
Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker Control,Monitor Speaker
Level Control, Siren Level Control, Siren Level Control, Siren Level Control, Siren eX 866A
Level Control Level Control Level Control Level Control

Auto Mic OFF 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min. 15 sec. to 2 min.

Number of Programmable Functions 10 20 40 120

Number of Connectable Units 8 (Include Emergency Mic) 8 (Include Emergency Mic) 8 (Include Emergency Mic) 8 (Include Emergency Mic)

Communication Protocol RS 485 RS 485 RS 485 RS 485

Connector RJ45, RJ45, RJ45, RJ45, eX 867A


panel feed through connector panel feed through connector panel feed through connector panel feed through connector

Communication Distance 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable) 1.2 km (Shielded Cable)

Power Requirement 24 Vdc (Regulated), 0.18 A 24 Vdc (Regulated), 0.19 A 24 Vdc (Regulated), 0.23 A 24 Vdc (Regulated), 0.31 A

Material & Finish ABS Resin & Aluminium, Epoxy Coated Black

Dimension ( W x H x D ) 210 x 64.5 x 185 mm 210 x 64.5 x 185 mm 210 x 64.5 x 185 mm 430 x 64.5 x 185 mm
eX 868A
Weight 1.2 kg 1.2 kg 1.2 kg 1.2 kg

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
09
VECTUS VL Series
Centralised Network PA System

VECTUS VL Series - Centralised Network PA System


The VL Series is a combination of PA system hardware and software built on VECTUSnet, AEX SYSTEM’s high-level proprietary integrated network
communication protocol which is built on top of TCP/IP. The ontology of VECTUSnet is to heuristically optimize the interactive operation of multiple
subsystem on network environment. It has been specifically created by AEX SYSTEM to provide the most manageable integration of Digital Audio,
Video & Data Information.

This allows for the implementation of a centralised PA system with VECTUS array of paging and surveillance features. The VL Series also makes
previously unattainable integration of the conventional PA system with other building services possible. TCP/IP compliant systems such as the Fire
Alarm System, CCTV System, Intrusion System and Building Management System can now be integrated to provide instantaneous voice assisted
response to each system. All these are accomplished within a single network system.

AUDIO FEATURES Availability Web Services


- PC Paging with Graphical
Zone Selection
- Text Streaming Feature Accessibility XML / SOAP
- Remote Text Streaming
via the Internet
- Digital Message Playback Integrity MODBUS / TCP
with Time Scheduler
- Audio Information Playback(MP3) Performance OPC / DA 2.0
SURVEILLANCE FEATURES
- Proactive Surveillance
VECTUSnet is the core of VECTUS Series of products. It ensures manageable - Visual Paging Reliability ODBC
- Visual Surveillance
integration of digital audio, video and data information and defines the system - Remote Live Video Recording Regulatory
VIDEO FEATURES
quality from the aspects of availability, accessibility, integrity, performance, - Live IP Video Broadcast
- Playback of Prerecorded Security
reliability, regulatory and security. VECTUSnet is fully TCP/IP compliant for Multimedia Content
- Real Time News &
maximum scalability and expandability purposes. It is backward compatible to all Information Display
- Uniformed Operations
upcoming systems developed by AEX SYSTEM.

VL 12 Multisystem Network Manager VL 21S Network Paging Station (Standard)


VL 22S Multi-System Network Paging Station (Standard)
Simplistic and user friendly Windows based graphical
user interface. Fully functional paging terminal with Audio & Text
Streaming capabilities.
Multi Network Station initialization and configuration. Windows based graphical interface.
Allows up to 8 standalone PA Systems to be Designed for use with both mouse control and
networked together. touch screen.

In-built background music and digital tuner


source player.

User-friendly time scheduling capabilities.

Receiving and making announcements over the


internet.

Text Streaming engine ready for Text Paging.

Fully functional paging terminal for multi PA


System paging. (Only available for VL 22S
Multi-System Network Paging Station).

VL 31 Station Adaptor Technical Specifications


VL 31
Serves as preamp unit for VL 21 and VL 22 audio to Audio Input Level 0 dBV, (Unbalanced)
conventional PA system.
Output Channels Paging Channel, Music Channel

Provides RS 485 and RS 232 data communication ports Audio Output 0 to +4 dBV (Adjustable) , 600 Ω (Balanced)
for interfacing with conventional PA System. Level & Impedence

Frequency Response 20 - 20 kHz

THD Distortion < 0.05 % @ 0 dB

Connectors 1 no. RJ45 Connector


2 nos.RJ45 Connectors
3 nos. 3.5 mm Headphone Connector
1 no. USB B - Type Connector
1 no. DC Power Supply Input (2.0 mm)
Indicators USB, Communication & CPU Off

Power Requirement 12 Vdc, 0.5 A

VL 31

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
10
VECTUS VN Series
Distributed Network PA System

VECTUS VN Series - Distributed Network PA System


Until recently, designing and building audio distribution systems with any degree of flexibility and intelligence has been a
difficult and expensive undertaking, requiring large expenditures on wiring, conduit, switching equipment and installation
labour. In addition, conventional public address systems using traditional analog technology have the added disadvan-
tage of often being difficult and prohibitively expensive to reconfigure once installed.

The VECTUS VN Series Distributed Network PA System is built on VECTUSnet, AEX SYSTEM’S own TCP/IP based
proprietary network communication protocol that provides a platform for integration of Digital Audio, Video & Data
information. With VECTUS, any audio input can be dynamically routed under software control to any audio output on the
network in any combination, providing unparalleled routing flexibility; all over standard Ethernet.

Full remote control over the network is a standard part of the protocol with re-routing of audio easily accomplished via
software rather than with expensive re-cabling or use of dedicated analog switching. Use of standard Ethernet wiring
further reduces costs. Most facilities have a data network that carries computer files, HVAC control, security, etc. Network
PA technology allows for the co-existence of audio and data traffic over existing standard Ethernet infrastructure resulting
in substantial savings in design and installation.

With previously unattainable routing, control and monitoring flexibility, reduced system set-up and installation costs and
delivery of high quality audio, VECTUS is set to introduce a whole new meaning of a Digital Public Address System.

VN 12 Network System Manager


The VN 12 Network System Manager provides a simplistic and user-friendly Windows based
graphical user interface for system initialization steps such as node search, node address
configuration, zone configuration and programming of the function keys at the paging consoles. After
system initialization, the audio routing pattern and priority setting is performed together with the
programming of the VECTUS I/O devices. The Network System Manager recommended to be
continuously logged on to the network at all time after the settings are done.

VN 13 Audio Streaming Manager


The VN 13 Audio Streaming Manager enables the user to stream up to 5 simultaneous channels of
audio from a PC into the network over a single Ethernet connection instead of traditional sources
such as CD, MD, or cassette deck. Each channel will have its own play list and playback mode,
which configurable from the GUI. It is ideal for applications that require selection of multi channels of
audio such as in a hotel where guests are able to select the music of their preference to their own
rooms or shopping mall where retail stores are able to select the program to meet their needs. The
Audio Streaming Manager is also able to perform 3 simultaneous time scheduled digital message
playback and 4 simultaneous event triggered digital message playback.

VN 21S Network Paging Station (Standard)


The VN 21S converts a normal workstation PC into a full fledged Paging Station with additional
features that never before could an ordinary paging console do. The operator now could make
zone selection either from a graphical map or floor plan to assist the operator visually or from
the GUI layout, similar to a paging console for button selection. The Text Streaming feature
allows announcements to be entered in text, real-time or pre-stored. The text will then be
synthesised into human voice and broadcasted. Text streaming assures that all announcements
made are consistent in voice, pronunciation, rate of speech and loudness. VT 61 paging
gooseneck microphone to be connected to the audio input of the PC is available for use with
the VN 21S

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
11
VECTUS VN Series
Distributed Network PA System

VN 31A I/O Interface Unit


The VN 31A I/O Interface Unit provides a mean of interfacing Technical Specifications
with sensors, switches and third party equipments that are not VN 31A
network enabled. The unit is capable of receiving both 5 digital Network Interface RJ-45, 10/100 Mbps , TCP/IP

High-Low signal and variable voltage analog signals such as Indicator 3 nos- LED status indicator
Trigger Menthod NO Dry Contact
from a temperature sensor. The unit also provides 5 digital open
No. of Control 5 nos. Control Input &
VN 31A collector output signal which can be used to trigger relays or 5 nos. Control Output

connect to other devices for external trigger. Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W

VN 34A Control Input Interface Unit Technical Specifications


VN 34A
The VN 34A Control Input Interface Unit provides a mean of Network Interface RJ-45, 10/100 Mbps , TCP/IP
interfacing with sensors, switches and third party Indicator 1 no. LED status indicator
equipments that are not network enabled. The unit is capable of Trigger Menthod NO Dry Contact

receiving 10 digital High-Low signal and variable voltage analog No. of Control 10 nos. Control Input

VN 34A signals such as from a temperature sensor. Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W

VN 35A Control Input Interface Unit Technical Specifications


VN 35A
The VN 35A Control Input Interface Unit provides a mean of Network Interface RJ-45, 10/100 Mbps , TCP/IP

interfacing with sensors, switches and third party Indicator 1 no. LED status indicator

equipments that are not network enabled. The unit is capable of Trigger Menthod NO Dry Contact
No. of Control 10 nos. Control Input
receiving 10 digital High-Low signal and variable voltage analog
VN 35A Power Requirement 220 ~ 240 Vac , 50 / 60 Hz , 11 W
signals such as from a temperature sensor.

Technical Specifications
VN 41
Input Sensitivity Single Channel, 0 dBV, Stereo (Unbalanced)
Frequency Response 22 Hz ~ 20 kHz
VN 41 Single Channel Network Audio Insert Distortion < 0.1% @ 0 dB
Au d io F o rm a t MP E G 1/Lay er 3 wi th 8 ~ 192 k bps
The VN 41 accepts one stereo channel of analog audio and Constant Bi t Rate
streams it into a 10/100 Mbit Ethernet network system with a Network Interface RJ 45, 10/100 Mbps E ther net ( A uto) , TCP/IP

source address to allow it to be routed to any receiving device Connectors 1 no. Single RJ45 w/LED Network Socket
1 no. Single RJ45 Socket , 1 no. RCA Stereo Jack
connected to the network. The System Manager assigns its 1 no. 2 Way Panel Feed Through Connector
VN 41 2 nos. 4 Way Panel feed Through Connector
destination according to the requirements of the user. Indicators Power, Input Signal and Line In Control
Line Control Input 1 no. Of Dry Contact Input
Control Input 2 nos. Of Dry Contact Input
Control Output 2 nos. Of Normally Open Dry Contact,
Withstand Voltage 24 Vdc, 5 mA
Power Requirement 220 ~ 240 Vac, 50/60 Hz, 11 W

Technical Specifications
VN 44
Input Sensitivity Single Channel, 0 dBV, Stereo (Unbalanced)
Frequency Response 22 Hz ~ 20 kHz
VN 44 4 Channel Network Audio Insert Distortion < 0.1% @ 0 dB
Au d io F o rm a t MP E G 1/Lay er 3 wi th 8 ~ 192 k bps
The VN 44 accepts four stereo channels of analog audio and Constant Bi t Rate
Network Interface RJ 45, 10/100 Mbps E ther net ( A uto) , TCP/IP
simultaneously streams it into a 10/100 Mbit Ethernet network
Connectors 4 nos. RJ45 w/LED Network Socket ,
system with individual source addresses which allows it to be 4 no. RJ 45 Socket

VN 44
routed to any receiving device connected to the network. The 4 nos. RCA Stereo Jack , 10 nos. 4 Way Panel
feed Through Connector
System Manager assigns their destinations according to the
Indicators Power, Input Signal and Line In Control
requirements of the user. Line Control Input 4 nos. Of Dry Contact Input
Control Input 8 nos. Of Dry Contact Input
Control Output 8 nos. Of Normally Open Dry Contact,
Withstand Voltage 24 Vdc, 5 mA
Power Requirement 220 ~ 240 Vac, 50/60 Hz, 22 W

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
12
VECTUS VN Series
Distributed Network PA System

VN 61A Single Channel Network Audio Extract


Technical Specifications
The VN 61A extracts one stereo channel of audio from the network and convert it back to analog VN 61A

audio, ready to be fed into a power amplifier. Each channel has a unique MAC address for the I n p u t Se n sitivity Single Channel 0 d BV, 6 0 0 Ω Mo n o (Ba la n ce d)

unit to receive audio and data from the sender. Gain control can be remotely done via a PC L in e O u t Au d io L e ve l 0 d BV, 6 0 0 Ω Mo n o (Ba la n ce d)

connected to the network with access rights. F re q u e n cy Re sp o n se 2 0 H z ~ 2 0 kH z

D isto rt io n < 0 .1 % @ 0 dB

Au d io F o rm a t M P E G 1 /L a y e r 3 w i th 8 ~ 1 9 2 k bps Constant B i t R a te

N e tw o rk I n t e rf a ce R J 4 5 , 1 0 /1 0 0 M b p s E th e r n e t ( A u to ) , T C P/I P
C o n n e cto rs 1 no. Sin g le RJ45 w /L ED N e tw o rk C o n n e ct o r
1 n o . Sin g le RJ4 5 C o n n e cto r
1 n o . D o u b le D e ck RJ4 5 C o n n e cto r
1 n o . D B9 Ma le C o n n e cto r , 1 no. USB Type A Connector
VN 61A 1 n o . 2 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r
2 n o s. 4 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r
I n d ica to rs Po w e r, Prio rit y a n d At t e n u a t o r O ve rrid e
C o n tro l I n p u t 1 n o . O f D ry C o n t a ct I n p u t
C o n tro l O u t p u t 3 n o s. O f N o rm a lly O p e n D ry C o n t a ct O u t p u t ,
W ith sta n d V o lta g e 2 4 V d c, 5 m A
Atte n u a to r O ve rrid e O u t p u t 1 no. Of N o rm a lly O p e n D ry C o n t a ct O u t p u t

Power Requirement 220 ~ 240 Vac, 50/60 Hz, 11 W

Technical Specifications
VN 64A
VN 64A 4 Channel Network Audio Extract
I n p u t Se n sitivity 4 Channel 0 d BV, 600 Ω Mono (Ba la n ce d)

The VN 64A extracts four stereo channel of audio from the network and convert it back to analog L in e O u t Au d io L e ve l 0 d BV, 600 Ω Mono (Ba la n ce d)

audio, ready to be fed into a power amplifier. Each channel has a unique MAC address for the F re q u e n cy Re sp o n se 2 0 H z ~ 2 0 kH z

D isto rt io n < 0 .1 % @ 0 dB
unit to receive audio and data from the sender. Gain control can be remotely done via a PC
Au d io F o rm a t M P E G 1 /L a y e r 3 w i th 8 ~ 1 9 2 k bps Constant B i t R a te
connected to the network with access rights.
N e tw o rk I n t e rf a ce R J 4 5 , 1 0 /1 0 0 M b p s E th e r n e t ( A u to ) , T C P/I P

C o n n e cto rs 4 nos. RJ45 w L ED N e tw o rk C o n n e ct o r


6 n o s. RJ4 5 C o n n e cto r
4 n o s. D B9 Ma le C o n n e cto r
4 n o s. U SB Typ e A C o n n e cto r
4 n o s. 8 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r
2 n o s. 4 W a y Pa n e l F e e d T h ro u g h C o n n e ct o r

I n d ica to rs Po w e r, Prio rit y a n d At t e n u a t o r O ve rrid e

C o n tro l I n p u t 4 n o s. O f D ry C o n t a ct I n p u t

VN 64A C o n tro l O u t p u t 1 2 n o s. O f N o rm a lly O p e n D ry C o n t a ct O u t p u t ,


W ith sta n d V o lta g e 2 4 V d c, 5 m A
Atte n u a to r O ve rrid e 4 n o s. O f N o rm a lly O p e n D ry C o n t a ct O u t p u t
O u tp u t W ith sta n d V o lta g e 2 4 V d c, 1 A

Power Requirement 220 ~ 240 Vac, 50/60 Hz, 27 W

VN 51 Network Paging Console


The VN 51 can be connected anywhere in the network via an RJ 45 port. The operator
can make the zone selection invidually or in pre-definedgroups. A built-in condenser
gooseneck microphone is provided together with a set of function selection buttons.
Technical Specifications
VN 51

Network Interface RJ-45, 10/100 Mbps , TCP/IP

Indicator 16 x 2 character LCD ,10 Individual Group LEDs , and TALK.

Switches 10 Individual Group Switches, Function Key (F1 & F2),


Paging Mode, Enter, Clear, TALK,
Reset button

Power Requirement +24 Vdc (Regulated), 0.12 A

VN 51

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
13
VECTUS VEB Series
TCP/IP Network Matrix PA System

VECTUS VEB Series


- TCP/IP Network Matrix PA System
The VECTUS VEB Series Network Matrix PA System is the latest TCP/IP based PA System offering from AEX
SYSTEM. The system runs on AEX SYSTEM’s tried and tested TCP/IP network communication
protocol that provides a platform for audio and control data routing over standard Ethernet (LAN)
infrastructure. The system is fully scalable and capable of supporting up to 32 simultaneous audio channels,
making it suitable for a simple application up to the most complex of public address systems.
Supporting a distributed architecture also makes the VEB Series an indispensible solution for mixed
development projects that consist of multiple blocks and multiple sub PA Systems that require site-wide
integration. With a failsafe mode, the VEB also ensures emergency evacuation functionality even with major
failure to the Ethernet (LAN) infrastructure.
The VEB Series also features advance touch screen Network paging consoles with extremely user friendly
graphic user interface. These network paging consoles can even be connected and used via WIFI
infrastructure allowing the consoles to be portable for added practicality.

VEB 12-IPC Network System Manager Unit


The Network System Manager unit is designed to provide overall system governance of the
VEB Network PA System. The unit will provide the user interface for system initialization
steps such as; VEB unit nodes search, VEB units address configuration, zone configuration VEB 12-IPC
and audio pattern routings. The Network System Manager can also act as a time scheduler
with pre-recorded messages as well as a background music source with up to 3 channels Technical Specifications
VEB 12-IPC
of background music streaming. In compliance to emergency evacuation requirements,
the unit will store the evacuation messages and provide event logging, announcement Network Interface 10/100 Mbps Ethernet TCP/IP

logging and fault monitoring of all critical components within the system. Indicators Power

Power Requirements 220~240 Vac mains 50/60 Hz

VEB 13-IPC Network Audio Streaming Manager Unit


The Network Audio Streaming Manager Unit allows the user to stream 8 simultaneous channels of audio into
the network over a single Ethernet connection. These audio channels can be retrieved by the VEB Network
Audio Extracts. Each channel will have its own playlist created by the user. These playlists are configurable by
from the GUI. This is an ideal solution for applications that require multiple audio channels like hotel, shopping
complexes, supermarkets, theme parks, etc.
VEB 13-IPC

VEB 21 Network Paging Station


The VEB 21 converts a normal workstation PC into a full fledged Paging Station with additional features that
never before could an ordinary paging console do. The operator now could make zone selection either from a
graphical map or floor plan to assist the operator visually or from the GUI layout, similar to a paging console
for button selection. The Text Streaming feature allows announcements to be entered in text, real-time or
pre-stored. The text will then be synthesised into human voice and broadcasted. Text streaming assures that
all announcements made are consistent in voice, pronunciation, rate of speech and loudness. VT 61 paging
gooseneck microphone to be connected to the audio input of the PC is available for use with the VEB 21

VEB 31 Control Input Interface


The VEB 31 provides a means of interfacing with other third party equipment and sensors Technical Specifications

that are not network compliant. The unit is capable of receiving 60 opto-coupler contact VEB 31

closures which can be programmed to trigger a number of functions in the system such Network Interface 10/100 Mbps Ethernet TCP/IP

as an automated fire evacuation broadcast. Indicators Power

Control Input 60 nos. Opto-coupler Control Input Sensors

Power Requirements 24 Vdc (Regulated), 0.3 A


VEB 31

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
14
VECTUS VEB Series
TCP/IP Network Matrix PA System

VEB 32 Control Output Interface


The VEB 32 provides a means of interfacing and triggering other third party equipment Technical Specifications

that are not network compliant. The unit provides 60 opto-coupler output trigger, which VEB 32

can be used to trigger external relays and devices. Network Interface 10/100 Mbps Ethernet TCP/IP

Indicators Power

Control Input 60 nos. Opto-coupler Control Output

Power Requirements 24 Vdc (Regulated), 0.7 A


VEB 32

VEB 42 Emergency Paging Panel VEB 42-EM Emergency Paging Extension Panel
The Emergency Paging Panel is rack mount unit providing emergency responders/firemen personnel to conduct evacuation in any given project. Each
Emergency Paging Panel comes with a handheld microphone and user friendly robust zone selection buttons. The Emergency Paging Panel complies
with evacuation safety standards with its entire connection path to critical equipment in the system fully monitored. The Emergency Paging Panel will
primarily communicate with the entire system via the LAN, however in the event of a failure of the LAN infrastructure, the system will revert to an
analogue failsafe mode and still allow paging throughout the system. The Emergency Paging Panel comes with 24 zones selection button, should
more zone selection button be required the unit can be cascaded with the VEB 42-EM Emergency Paging Extension Panel.

VEB 42 VEB 42-EM

Technical Specifications
VEB 42 VEB 42-EM

Network Interface 10/100 Mbps Ethernet TCP/IP N/A

No. of zone selection buttons 24 nos. Push to activate buttons 24 nos. Push to activate buttons

Communication UART R-COMM to VEB 42-EM UART R-COMM to VEB 42

Indicators POWER, Fault indicator, Emergency Mode activated, SIREN in progress, TALK POWER

Power Requirements 24 Vdc (Regulated), 0.5 A 24 Vdc (Regulated), 0.3 A

VEB 43 Network Paging Console


The Network Paging Console for the VEB Series is a state of Technical Specifications

the art touchscreen based paging console unit. It allows the VEB 43

user to operate the unit as well as select the zones via a user Network Interface RJ 45 10/100 Mbps Ethernet TCP/IP
WIFI Connectivity
friendly GUI. From the GUI the operator will be able to make
Touchscreen Dimension 10 inch
zone selection individually or in pre-defined groups based on
the client’s requirement. Being a network enabled console, the Microphone Non-removable condenser gooseneck
microphone with windshield
unit can be connected or relocated anywhere within the project
Power Requirements 12 Vdc, 2.5 A
without hassle - simply by connecting to the LAN’s datapoint. VEB 43
Future upgrade to the unit will also allow the unit to
communicate and make announcements via WIFI connection.

VEB 404-S 4-Channel Network Audio Insert


The VEB 404-S accepts 4 stereo channels of analogue audio, encodes and streams Technical Specifications
VEB 404-S
all channels out simultaneously via standard Ethernet (LAN). The unit will serve as a
Input Sensitivity 4 Channels 0 dBV (Stereo) RJ45 Connector
background music source audio insert for most projects allowing CD players, FM
tuners and the likes to be stream to any destination zone within the project. The user Audio Format CD Quality BGM Audio Codec

can utilize the Network System Manager to manage and control the routing pattern Network Interface 10/100 Mbps Ethernet TCP/IP

according to the user requirements remotely. Indicators Power, 4 nos. Input Signal and 4 nos. Line In Control

Control Input 4 nos. Dry Contact trigger for input activation

Power Requirements 24 Vdc (Regulated), 0.1 A


VEB 404-S

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
15
VECTUS VEB Series
TCP/IP Network Matrix PA System

VEB 601-S Single Channel Network Audio Extract


Technical Specifications
The VEB 601-S extracts single channel of audio from the network and converts it back
VEB 601-S
to analogue audio. This audio can then be fed into AEX SYSTEM’s range of power
Audio Output Level 0 dBV (600 Ω Balanced) RJ45 Connector
amplifier models. Each unit has a unique IP address allowing the unit to receive audio
Audio Format CD Quality BGM Audio Codec
from the desired source. Gain control can be remotely controlled using the Network
Network Interface 10/100 Mbps Ethernet TCP/IP
System Manager via the network.
Indicators Power, 1 no. Analog Link Indicator, 1 no. ATT OVR
Control Output 1 no. ATT OVR (Attenuator Override) Control output
1 no. Control Output (user programmable)

VEB 601-S Power Requirements 24 Vdc (Regulated), 0.3 A

VEB 604-S 4-Channel Network Audio Extract


The VEB 604-S extracts 4 channels of audio from the network and converts it back to Technical Specifications

analogue audio. This audio can then be then be fed into AEX SYSTEM’s range of power VEB 604-S
Audio Output Level 4-Channels of 0 dBV (600 Ω Balanced) RJ45 Connector
amplifier models. Each of the 4 channels on the unit has a unique IP address allowing
Audio Format CD Quality BGM Audio Codec
the unit to receive its own dedicated audio from desired sources available. Individual
Network Interface 10/100 Mbps Ethernet TCP/IP
gain control can be remotely controlled using the Network System Manager via the
Indicators Power, 1 no. Analog Link Indicator, 4 nos. ATT OVR
network.
Control Output 4 nos. ATT OVR (Attenuator Override) Control output
4 nos. Control Output (user programmable)

Power Requirements 24 Vdc (Regulated), 0.75 A


VEB 604-S

VEB 81 SIP Audio Gateway


The VEB 81 provides a means of interfacing the VEB Series PA System with other third Technical Specifications
party SIP-enabled systems. An example of such integration would be with an IP VEB 81
Telephony/Intercom system. With the VEB 81 installed, it would allow any of the IP based Network Interface 10/100 Mbps Ethernet TCP/IP
handset units to select any of the PA System zones and make announcements through
Indicators Power
the handset unit.
Power Requirements 220 ~ 240 Vac, 50/60 Hz, 11 W

VEB 81

VEB 82 WIFI Audio Gateway


The VEB 82 WIFI Audio Gateway provides a means for remote devices such as the Technical Specifications
VEB 43 Network Paging Console to make access the PA System and make VEB 82
announcements via WIFI infrastructure. The VEB 82 WIFI Audio Gateway would also Network Interface 10/100 Mbps Ethernet TCP/IP
allow Android and iOS based portable devices with AEX System’s proprietary VEB App
No. of simultaneous Max. 5
to access and control the PA System wirelessly. The VEB 82 is capable of supporting up client devices

to 5 devices simultaneously at any given time. Indicators Power

Power Requirements 220 ~ 240 Vac, 50/60 Hz, 11 W

VEB 82

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
16
VECTUS VEB Series
TCP/IP Network Matrix PA System

VEB 83 Internet Audio Gateway


The VEB 83 Internet Audio Gateway allows access and control to the VEB Series PA
Technical Specifications
System in remote locations via the internet. With the VEB 83 installed as part of the VEB
VEB 83
Series PA System in a remote site, the user will be able to access the system and make
Network Interface 10/100 Mbps Ethernet TCP/IP
announcements via the internet utilizing the VEB 21 Network Paging Station. Multiple
sites with PA system could be integrated as a total system utilizing the VEB 83. Indicators Power

Power Requirements 220 ~ 240 Vac, 50/60 Hz, 11 W

VEB 83

VAC 04 Network Automatic Amplifier Changeover Unit VAC 08 Network Automatic Amplifier
VNS 16
Changeover Unit
The VAC 04 and VAC 08 Network Automatic Amplifier Changeover unit provides monitoring and surveillance of power amplifiers within a project via
the LAN. The unit is capable of monitoring up to 4 units (VAC 04) and 8 units (VAC 08) of power amplifiers for faults. Upon fault detection the unit will
automatically changeover the faulty amplifier to a standby amplifier and at the same time report the fault to the Network System Manager or Network
Paging Station.

VAC 04 VAC 08

Technical Specifications
VAC 04 VAC 08

Network Interface 10/100 Mbps Ethernet TCP/IP 10/100 Mbps Ethernet TCP/IP

No. of channels per unit 4 Channels Duty, 1 Standby 8 Channels Duty, 1 Standby

Max. power handling per channel 1200 W 1200 W

Indicators Power, 5 Bi-Colour indicators for 4 Duty and 1 Standby amplifier status Power, 9 Bi-Colour indicators for 8 Duty and 1 Standby amplifier status

Power Requirements 24 Vdc (Regulated), 0.33 A 24 Vdc (Regulated), 0.55 A

VLS 12 Network Matrix Expander


The Network Matrix Expander allows the increase of outputs within a PA System. Technical Specifications
These output can easily be created in accordance to the client’s requirements and VLS 12
controlled to be switched ON or OFF (during announcements and music routing)
Network Interface 10/100 Mbps Ethernet TCP/IP
directly via the LAN using the Network System Manager, Network Paging Console or
the Network Paging Station. Each Network Matrix Expander is capable of providing Indicators Power, 12 nos. Output status indicator (ON/OFF)

12 outputs and multiple unit can be used within a project for large scale applications. Number of output 12 nos.

Max Current Handling 12 A per output (1200W)


per output

Power Requirements 24 Vdc (Regulated), 0.42 A


VLS 12

VNS 16 16-Port ELV Network Switch


With the growing emergence of ELV services such as the PA Systems, IP CCTV, Card Technical Specifications

Access, etc. being migrated to the network, there is a high requirement for reliable and VNS 16

secure network infrastructure to support them. The 16-Port ELV Network Switch was Ports 16 nos. RJ 45 Connectors for 10 Base-T/100 Base-T;
Auto negotiated port for connecting 10/100 Base-T devices
developed to support such demands of these ELV Systems on the LAN with better
Cabling Type Unshielded twisted pair (UTP) Cat 5 or better
performance in delivering audio/video streaming along with improved performance
Indicators Power, 16 nos. Link/Activitity,
when working with broadcast packet conditions. The VNS 16 unit is a fixed configuration 16 nos. Speed (10/100 Base-T)
16 port Fast Ethernet switch and is easily scalable to suit project requirements. Standards 802.3 10 Base-T Ethernet
802.3u 100 Base-TX Fast Ethernet

VNS 16

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
17
Features

1 PC Paging 5 Time Scheduling


PC Paging provides flexibility to allow any existing computer Time scheduling programs allows the system to perform
workstations to be utilized as a paging station. automated daily tasks such as broadcasting of hourly messages such
as opening times and closing times of a business operation. This
allows business operations to run leaner and more efficiently.

2 Text Streaming 6 Background Music Source


Text Streaming provides consistent announcements by allowing audio The VECTUS system also doubles up as a BGM source for MP3
paging to be done simply by typing the announcements into a paging playback.
terminal.

Amplifier

3 Internet Paging / eText Streaming 7 System Status Monitoring


Live paging can be simultaneously done up to four sites located The overall system status can be monitored via the VECTUS software.
outside the LAN. Three modes of broadcast are available; Direct All critical component's status such as amplifier status can easily be
Audio Streaming, Delayed Audio Streaming (with Time checked online.
Scheduler) or Text Streaming when the bandwidth is limited.

R3 Z3
FL Z1
R2
FL 2
R
FL 1
R Z2 Z4
FL
D
GN

4 Graphical Zone Selection 8 Fail Safe Mode


Allows operators to accurately select zones during announcements In the event of a failure to the network infrastructure, the VEB 42
from a virtual building displayed. Emergency Paging Panel will automatically switch to a fail safe mode
and allow announcement to the whole system.

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
18
Power Amplifiers

MA 2000 Series Mixer Amplifier


The MA 2000 Series is the range of Mixer Amplifiers that is able to handle 4 microphone inputs and auxiliary inputs, making the MA 2000
Series suitable for small and medium scale public address applications, such as mosque, office, restaurants or pubs, fitness clubs,
auditoriums, warehouses, factories and retail stores.The MA 2000 series comes with individual input gain controls with a master volume
control. Bass and Treble controls are provided for the user’s equalisation preference. The MA 2000 series is integrated with voice muting
function for Mic 1, thus giving it the highest priority to override other sources during emergency situation. Able to operate off mains or an
external battery, the MA 2000 Series is a viable solution for any mobile application from a family day sports event to a large-scale garden
party. Technical Specifications
MA 2006 MA 2015 MA 2025 MA 2415 MA 2425

Rated Output 60 W at 100 V 150 W at 100 V 250 W at 100 V 150 W at 100 V 250 W at 100 V

Frequency Response 40 Hz - 20 kHz

Input Sensitivity MIC 1 6.3 mm Phone socket, 0 dB/-60 dB,600 Ω Balanced (with voice activated muting function and phantom power dip switch)

MIC 2 - 4 6.3 mm Phone socket, 0 dB/-60 dB, 600 Ω Balanced (with phantom power dip switch)
AUX
1 & 2 : (MA 2006, MA 2015,MA 2025)
RCA connector, -20 dB 10k Ω Stereo input
1 - 3 : (MA 2415, MA 2425)

MA 2006 / MA 2015 / MA 2025 REC OUT RCA connector, 0 dB 600 Ω unbalanced Stereo output

Zone Selection No Zone selection No Zone selection No Zone selection 4 Zone selection 4 Zone selection

Protection Circuit Over current and short circuit protection.

AC Power Consumption 85 W 210 W 355 W 210 W 355 W

DC Power Supply 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac, 220 ~ 240 Vac,
50Hz, 85 W or 50Hz, 210 W or 50Hz, 355 W or 50Hz, 210 W or 50Hz, 355 W or
24 V , 2.3 A 24 V , 5.7 A 24 V , 9.4 A 24 V , 5.7 A 24 V , 9.4 A

Dimensions (W x H x D) 430 x 90 x 250 mm


MA 2415 / MA 2425 - 4 Zone
Weight 6.6 kg 8.2 kg 11.2 kg 8.3 kg 11.3 kg

RM 04 Remote Microphone Technical Specifications


RM 04
Output sensitivity 0 dB

Frequency Response 20 Hz - 20 kHz

Indicators Zone selection LED indicator Chime in progress / Talk indicator

Control 4 no. zone selection button (push to select and push to release) Talk button

RM 04 Chime Pre-announcement 4-tone ascending, Post-announcement 4-tone descending

Material & Finish ABS, Graphite Black

Dimensions (W x H x D) 400 x 130 x 140 mm

Weight 0.4 kg

PB 1000 Series Audio Power Amplifier


The PB 1000 Series Audio Power Amplifiers are completely engineered
with the latest advancement in audio technology. Vast improvements
were made to the sonic performance and operation stability with current
protection circuitry. The power amplifiers provide wide frequency
response, low THD level and high S/N ratio. The PB 1000 Series is also
incorporated with toroidal transformer technology which reduces
electromagnetic noise and improves power efficiency. The audio power
amplifier features 2 inputs; Program Input and Priority Input. The Priority
Input which is used during emergency paging will automatically
override the Program Input, normally used for announcements and
background music. All models can operate on both AC mains power or
PB 1024 / PB 1048/ PB 1224 / PB 1060 / PB 1260 / PB 1120 a backup 24 Vdc power source, providing continuous uninterruptible
PB 1406 / PB 1412 operation even during a power failure.
Technical Specifications

PB 1406 PB 1412 PB 1024 PB 1224 PB 1048 PB 1060 PB 1260 PB 1120

Rated Output Power 4 x 60 W rms 4 x 120 W rms 1 x 240 W rms 2 x 240 W rms 1 x 480 W rms 1 x 600 W rms 2 x 600 W rms 1 x 1200 W rms

Frequency Response at rated output 40 Hz to 18 kHz

Total Harmonic Distortion < 1% (at rated output, f=1 kHz)

Signal-to-Noise Ratio Better than 90 dB (IEC A)

Input Connections 1 Program and 1 Priority Terminal (RJ 45)

Input Level 0 dB

Input Impedance 10 kΩ (Balanced)

Load Impedance (per channel) 167 Ω 84 Ω 42 Ω 42 Ω 21 Ω 17 Ω 17 Ω 9Ω

Power Consumption 320 VA 640 VA 320 VA 640 VA 640 VA 740 VA 1480 VA 1480 VA

Power Requirement 220~240 Vac mains 50/60 Hz or 24 Vdc

Operation Temperature -10°C to 40°C

Storage Temperature -40°C to 70°C

Relative Humidity < 95%

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
19
Control & Monitoring

AC 04S & AC 08S Automatic Amplifier Changeover Unit


AC 04S & AC 08S provides supervision of duty amplifiers and provides automatic changeover of faulty amplifiers to a standby amplifier. The
AC 04S is capable of monitoring 4 duty amplifiers with automatic changeover to 1 standby amplifier while the AC 08S is capable of monitoring
up to 8 Duty amplifiers with changeover to 1 standby amplifier. The standby amplifier will back-up the duty amplifiers on a first come first serve
basis. The unit also provides aural and visual indication to notify users of faulty amplifier.

Technical Specifications

AC 04S
C onne c te d Pow e r Handling Per Channel 1200 W per channel

N os. Of C ha nne ls pe r U nit 4 Cha nne ls Duty , 1 Channel Standby

C onne c tor s Pow e r : 2 -Wa y Pa ne l Fe e d Thr ough C onne c tor

I/O ( 1 0 0 V L ine ) : 4 -Wa y Pa ne l Fe e d Thr ough C onne c tor

I/O ( L ine L e ve l) : RJ 45 Socket


General dry contact fault

Indic a tor s POWER, 5 Bi - Color Indicator for 4 Duty & 1 Standby Amplifier Status
AC 04S
Pow e r Re quir e me nts 2 4 Vdc ( Re gula te d) , 0.28 A

D ime nsions ( W x H x D ) 483 x 44 x 150 mm

M a te r ia l & Finish Mild Steel Casing, Epoxy Black

Technical Specifications

AC 08S
C onne c te d Pow e r Handling Per Channel 1200 W per channel

N os. Of C ha nne ls pe r U nit 8 Cha nne ls Duty , 1 Channel Standby

C onne c tor s Pow e r : 2 -Wa y Pa ne l Fe e d Thr ough C onne c tor

I/O ( 1 0 0 V L ine ) : 4 -Wa y Pa ne l Fe e d Thr ough C onne c tor

I/O ( L ine L e ve l) : RJ 45 Socket


AC 08S General dry contact fault

Indic a tor s POWER, 9 Bi - Color Indicator for 8 Duty & 1 Standby Amplifier Status

Pow e r Re quir e me nts 2 4 Vdc ( Re gula te d) , 0.5 A

D ime nsions ( W x H x D ) 483 x 44 x 150 mm

M a te r ia l & Finish Mild Steel Casing, Epoxy Black

Technical Specifications
LM 08 Line Supervisory Unit LM 08
The LM 08 Line Supervisory Unit provides real-time monitoring and
Connected Power Handling Per Channel Up to 500 W rms max
surveillance for 8 loudspeaker lines, up to a distance of 1 km, monitoring for
Nos. Of Channels per Unit 8 channels
short circuits, open circuits and ground leaks. Utilising impedance checking
Connectors Power : 1 no. 2-Ways Panel Feed Through Connector
methodology, the unit allows for monitoring of branched loudspeaker network Control & Overriding Power : 1 no. 4-Ways Panel Feed Through Connector
and audio attenuator insertion with minimal setup requirements. An LCD Communication : 1 no. Double Deck RJ 45 Socket
I/O (100 V Line) : 8 nos. 4-Ways Panel Feed Through Connector
display provides a simple user-friendly interface for setup and monitoring. The
Priority & Volume Overriding : 8 nos. 4-Ways Panel Feed Through Connector
unit is capable of interfacing with other equipment via RS 485 for remote
Control Selection Button (Enter, Clear, Up, Down, Left, Right)
monitoring, fault event logging and fault notification.
Control Output Withstand Voltage 24 Vdc 40 mA (Fault Trigger)
Withstand Voltage 24 Vdc 1 A (Attenuator Override Output)

Interval Timer Duration 1 min, 5 min, 1 hour, and 24 hours

Measurement Sensitivity +/- 10 % of Line Impedance

Indicators 2 x 16 Characters LCD Display


LM 08
Power Requirements 24 Vdc (Regulated), 0.45 A

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
20
Control & Monitoring

AM 10S Amplifier Monitoring Panel Technical Specifications


The AM 10S Amplifier Monitoring Panel provides aural and visual AM 10S

monitoring of the output from the power amplifier, designed for 100V line Control Source Selector : 10 interlocking switches with
mechanical indicator buttons
distributed speaker system. The AM 10S allows the selection of any one of up to Audio Control : Stepless volume control
10 power amplifier outputs to be monitored.Visual indication is provided by a VU
Input Voltage 100 V ; 5 kΩ
meter that indicates the output level of the power amplifier. Aural monitoring is
provided by a high quality dynamic full range loudspeaker built into the enclosure Loudspeaker Component Dynamic Full Range Loudspeaker
of the unit. It is 19” EIA standard rack mountable and only takes up 1U space.
Level Meter Analog VU Meter

Material & Finish Mild Steel; Epoxy Coated

Dimensions (W x H x D) 480 x 44 x 150 mm

Weight 2.1 kg
AM 10S

PS 06 Power Supply Unit Technical Specifications


PS 06
The PS 06 Power Supply Unit provides regulated 24 Vdc power supply up to a Input 220 ~ 240 Vac; 50/60 Hz
maximum of 6 amperes. Utilizing solid state technology is features protection 24 Vdc Battery Backup

against short circuit and overloading.There is a provision in the PS 06 to allow for Output 24 Vdc (Regulated), 6A max
connection to an array of batteries for backup power supply, in the event of AC
Regulation +/- 0.5 Vdc, 0.1 V ripple max.
power failure, the battery power automatically switches to supply the equipments
connected to the power supply unit. Protection Solid state & fast blow glass tube fuse
DC Fuse Rating : 6A, Short
AC Fuse Rating : 2A, Short

Indicators AC mains fault ~ Red LED


Power ON ~ Green LED
Backup Power ~ Green LED

Dimensions (W x H x D) 215 x 44 x 150 mm


PS 06
Weight 1.4 kg

LS 12A Speaker Line Selector


The LS 12A Speaker Line Selectors enables switching between two inputs such as
Technical Specifications
background music, paging in a public address system and allows for splitting and
LS 12A
control of sub-zones within a PA system.The unit provides users the flexibility to
Connector 100 V line : 2.5 mm Plug-in screw type,
manage announcements and background music within all the zones in a project. Panel feedthrough terminal block
Utilizing an array of relays, the unit has 12 buttons on the facial for manual control Switch Buttons 12 nos. push buttons for line selection
of the 12 available speaker zones allowing the zones to be switched ON or OFF. 1 number ALL CALL button

The LS 12A also comes with an additional ALL CALL button which automatically Indicator Type Green LED indicator for each zone

selects all 12 zones on the unit for added convenience. Control Input Dry contact transistor closure

Max. Current Handling 1200 W per channel

Power Requirement 24 Vdc, 0.25 A


Dimensions (WxHxD) 430 x 44 x 150 mm
LS 12A

ATS Series Audio Attenuator


AP Series Local Source Patch Panel
The ATS Series Audio Attenuator are aesthetically designed to blend into most architectural surrounding without any matching complications with
other electrical fittings. The units are constructed from high impact ABS material with a white matte finish, making the units highly durable while
complementing most walls’ surface finishing.Apart from its aesthetic aspects, serious thought has been put into the safety aspect of the ATS
Series, bearing in mind that each unit comes with a built-in overriding relay, which when triggered will automatically set the output level to
maximum. The AP Series serves as a patch-in panel for a local 100V line source to the loudspeakers connected to it. The units also come with overriding
relay for emergency overriding of the local source.

AP 01 AT 06S AT 30S AT 60S AT 120S

Technical Specifications
AP 01 AT 06S AT 30S AT 60S AT 120S

Maximum Power 120W (100V) 6W (100V); 3W (70V) 30W (100V); 15W (70V) 60W (100V); 30W (70V) 120W (100V); 60W (70V)

Attenuation 5 level of -6 dB per step 5 level of -6 dB per step 5 level of -6 dB per step 5 level of -6 dB per step
(0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB, (0 dB, -6 dB, -12 dB,
-18 dB, - dB) -18 dB, - dB) -18 dB, - dB) -18 dB, - dB)
8

8
8

Maximum Insertion Loss - 0.5 dB - 0.5 dB - 0.5 dB - 0.5 dB

Material & Finish ABS Resin, White ABS Resin, White ABS Resin, White ABS Resin, White ABS Resin, White

Emergency Override 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A 24 Vdc, 0.01 A

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
21
Loudspeakers

CA Series 6W Ceiling Loudspeaker


Technical Specifications
The slim profiled CA 563 and CA 564E ABS Grille Ceiling Loudspeakers comes with an
CA 563 CA 564E
epoxy coated fine metal mesh that easily matches to most ceiling surfaces. Being spring
Rated Input 100 V : 6 W (6 - 3 - 1.5 W) 100 V : 6 W (6 - 3 - 1.5 W)
mounted eases installation and improves aesthetics. Both CA 563 and CA 564E come
70 V : 3 W (3 - 1.5 - 0.75 W) 70 V : 3 W (3 - 1.5 - 0.75 W)
with a 120 mm dynamic full range loudspeaker component, making the unit suitable for a
Maximum Power 9W 9W
wide range of application, be it voice or music. CA 564E comes readily fitted with an
enclosure for installations that call for it. A 6W rated multi-tapping line matching Rated Impedance 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ)

transformer is built into the unit, suitable for use with 100V line systems. Sensitivity 92 / 100 dB 90 / 98 dB
( 1 W / rated at 1m )
Coverage Angle 180 ° 180 °
( 1 kHz, -6 dB )
Frequency Response 100 Hz ~ 20 kHz 110 Hz ~ 20 kHz
CA 563 CA 564E Speaker Component 120 mm Dynamic Full 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065

CE Series 6W Ceiling Loudspeaker


The CE 565 and CE 565E Ceiling Loudspeakers suits low ceiling applications such Technical Specifications

as supermarkets, offices and restaurants, reproducing voice announcements and CE 565 CE 565E

background music with high clarity. Mounted on to a high impact ABS grille with an Rated Input (100 V) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W )
70 V : 3 W ( 3 - 1.5 - 0.75 W ) 70 V : 3 W ( 3 - 1.5 - 0.75 W )
off-white finish, its 120 mm dynamic full range loudspeaker component reproduces
Maximum Power 9W 9W
the source signal with high intelligibility due to its extended frequency response. An
Rated Impedance 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ )
aesthetically pleasing front metal mesh comes as a standard feature. Both models
are spring mounted on to the ceiling for ease of installation. They come with a Sensitivity
(1W / rated at 1m)
90 / 98 dB 90 / 98 dB

multiple impedance line matching transformer, suitable for 70 V or 100 V distributed Coverage Angle 180 ° 180 °
loudspeaker system with a maximum power handling of 6 W rated at 100 V. Model (1 kHz, -6 dB)
CE 565E comes readily fitted with a metal back enclosure to prevent fire from Frequency Response 110 Hz ~ 20 kHz 110 Hz ~ 20 kHz
speading via the ceiling cavity. Speaker Component 120 mm Dynamic Full 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065


Mounting Method Spring Spring

CE 565 CE 565E Applicable Ceiling 3 ~ 25 mm 3 ~ 25 mm


Thickness

CM Series Flush Mount Ceiling Loudspeaker


The CM Series Flush Mount Ceiling Loudspeakers are designed for low ceiling applications in a public address system. The loudspeakers utilise
torsion springs for easy installation and to eliminate visible mounting screws. The CM Series consist of 6 models: CM 361 ( 75 mm transducer );
CM 461/CM 461E ( 100 mm transducer ) ; CM 561E ( 130 mm transducer ); CM 611/ CM 611E ( 160 mm transducer ). All models come with a
multiple impedance line matching transformer, suitable for 70V or 100V distributed loudspeaker system. Suffix ‘E’ which follows the model name,
denotes that the model comes with a metal back enclosure.

CM 361 CM 461 CM 461E CM 561E CM 611 CM 611E


Technical Specifications

CM 361 CM 461 CM 461E CM 561E CM 611 CM 611E

Rated Input (100 V) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 6 W ( 6 - 3 - 1.5 W ) 100 V : 10 W ( 10 - 5 - 2.5 W ) 100 V : 10 W ( 10 - 5 - 2.5 W )
70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 3 W ( 3 - 1.5 - 0.8 W ) 70 V : 5 W ( 5 - 2.5 - 1.3 W ) 70 V : 5 W ( 5 - 2.5 - 1.3 W )

Maximum Power 9W 9W 9W 9W 15 W 15 W

Rated Impedance 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 1 kΩ ( 1 - 2 - 4 kΩ ) 1 kΩ ( 1 - 2 - 4 kΩ )

Sensitivity (1 W / rated at 1 m) 88 / 96 dB 90 / 98 dB 90 / 98 dB 90 / 98 dB 92 / 102 dB 92 / 102 dB

Coverage Angle (1 kHz, -6 dB) 180 ° 180 ° 180 ° 180 ° 180 ° 180 °

Frequency Response 64 Hz ~ 20 kHz 64 Hz ~ 20 kHz 100 Hz ~ 20 kHz 115 Hz ~ 20 kHz 64 Hz ~ 20 kHz 100 Hz ~ 20 kHz

Speaker Component 75 mm Dynamic Full 100 mm Dynamic Full 100 mm Dynamic 130 mm Dynamic Full 160 mm Dynamic Full 160 mm Dynamic Full
Range Loudspeaker Range Loudspeaker Full Range Loudspeaker Range Loudspeaker Range Loudspeaker Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
22
Loudspeakers

CS Series Splashproof Ceiling Loudspeaker


The CS Series Splashproof Ceiling Loudspeakers are designed for installations
Technical Specifications
where the unit is subjected to moisture & high humidity such as pool side,
CS 332 CS 332L
bathroom or at open covered walkways. These ceiling loudspeakers are able to
Rated Input (100 V) 100 V : 6 W ( 6 - 3 - 1.5 W ) 6W
withstand moisture due to its high impact ABS grille and its 75 mm dynamic full 70 V : 3 W ( 3 - 1.5 - 0.8 W )
range loudspeaker component, being constructed for moisture proofing. A zinc Maximum Power 9W 9W
plated front metal mesh, finished in off-white, provides an elegant appearance for
certain models. Its unique torsion spring mounting system reduces installation Rated Impedance 1.7 kΩ ( 1.7 - 3.3 - 6.7 kΩ ) 8Ω

time without the need of visible screws. CS 332 come with a multiple impedance Sensitivity 88 / 96 dB 88 / 96 dB
(1W / rated at 1m)
line matching transformer, suitable for 70V or 100V distributed loudspeaker
Coverage Angle 180 ° 180 °
system with a maximum power handling of 6W rated at 100V. All models come with (1 kHz, -6 dB)
back enclosure to prevent crosstalk between adjacent zones via the ceiling void. Frequency Response 250 Hz ~ 20 kHz 250 Hz ~ 20 kHz

Speaker Component 75 mm Dynamic Full 75 mm Dynamic Full


Range Loudspeaker Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065


CS 332 CS 332L

CX Series Flush Mount 2-Way Coaxial Ceiling Loudpeaker


Coaxial Ceiling Loudspeakers are well sought-after in installations that require good musical quality reproduction for its ability to produce a wider
audio bandwidth due to its individually dedicated transducers for the high & low frequencies. Being coaxially mounted improves the sound
alignment, close to a single point-source. The CX 611 is fitted with a 160 mm coaxial transducer while the CX 815, a 200 mm coaxial transducer.
Both models are transformerised for 100V line systems, 10W (CX 611) and 15W (CX 815). Its slim profile grille & fine metal mesh makes the unit
blend into its surroundings seamlessly. Both models have options of a metal back enclosure; CX 611E and CX 815E.

CX 611 CX 611E CX 815 CX 815E


Technical Specifications
CX 611 CX 611E CX 815 CX 815E

Rated Input 100 V : 10 W (10 - 5 - 2.5 W) 100 V : 10 W (10 - 5 - 2.5 W) 100 V : 15 W (15 - 7.5 - 3.8 W) 100 V : 15 W (15 - 7.5 - 3.8 W)
70 V : 5 W (5 - 2.5 - 1.3 W) 70 V : 5 W (5 - 2.5 - 1.3 W) 70 V : 7.5 W (7.5 - 3.8 - 1.9 W) 70 V : 7.5 W (7.5 - 3.8 - 1.9 W)

Maximum Power 15 W 15 W 22.5 W 22.5 W

Rated Impedance 1 kΩ (1 - 2 - 4 kΩ) 1 kΩ (1 - 2 - 4 kΩ) 670 Ω (670 - 1330 - 2670 Ω) 670 Ω (670 - 1330 - 2670 Ω)

Sensitivity ( 1 W / rated at 1m ) 92 / 102 dB 92 / 102 dB 94 / 106 dB 94 / 106 d B


. .
Coverage Angle ( 1 kHz, -6 dB ) 130 ° 130 ° 120 ° 120 °

Frequency Response 55 Hz ~ 20 kHz 65 Hz ~ 20 kHz 60 Hz ~ 20 kHz 70 Hz ~ 20 kHz

Speaker Component 160 mm 2-Way Coaxial Loudspeaker 160 mm 2-Way Coaxial Loudspeaker 200 mm 2-Way Coaxial Loudspeaker 200 mm 2-Way Coaxial Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065

2-Way Foreground Loudspeaker


The FG 530W is a 2-way Foreground Loudspeaker which is suitable for application which requires high audio quality and precise sound
projection applications such as in hypermarket, exhibition center and sports complex. The unit incorporates a 120 mm dynamic full range
transducer to produce low frequencies while a 25 mm dome tweeter is used to produce higher frequencies. The FG 530W is versatile when
comes to mounting which can be done by surface mounting or using the mounting bracket provided to mount the unit at a tilt angle of either
0° or 20° with 180° pan capability. An 8 Ω model is available for low impedance applications.
Technical Specifications
FG 530W FG 530W-WP FG 530WL
Rated Input 100 V : 30 W (30 - 15 - 7.5 W) 100 V : 30 W (30 - 15 - 7.5 W) 50 W (Continuous Program)
70 V : 15 W (15 - 7.5 - 3.8 W) 70 V : 15 W (15 - 7.5 - 3.8 W)

Maximum Power 45 W 45 W 200 W ( Peak Program)

Rated Impedance 330 Ω (330 - 670 - 1330 kΩ) 330 Ω (330 - 670 - 1330 kΩ) 8Ω

Sensitivity (1 W / rated at 1m) 90 / 105 dB 90 / 105 dB 90 / 105 dB

Coverage Angle (4 kHz, -6 dB) 90 x 90 ˚ 90 x 90˚ 90 x 90 ˚

Frequency Response 75 Hz ~ 20 kHz 75 Hz ~ 20 kHz 75 Hz ~ 20 kHz

Speaker Component LF : 1 no. 120 mm Dynamic Full LF : 1 no. 120 mm Dynamic Full LF : 1 no. 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker Range Loudspeaker
HF : 25 mm Neodymium HF : 25 mm Neodymium HF : 25 mm Neodymium
Magnet Dome Tweeter Magnet Dome Tweeter Magnet Dome Tweeter
FG 530W
FG 530WL Safety Acc. to EN 60065 Acc. to EN 6006 5 Acc. to EN 60065

FG 530W-WP Finish White White White

Dust & Water Prodection IP65 (acc. to IEC 529)

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserv e d
23
Loudspeakers

Outdoor Garden Loudspeaker Technical Specifications


GD 6
The GD 6 is designed for use in outdoor garden applications where
Rated Input 100 V : 30 W (30 - 15 - 7.5 W)
the loudspeaker unit is tasked to evenly cover a large area without 70 V : 15 W (15 - 7.5 - 3.8 W)
compromising on the clarity of the system. The full range garden
Maximum Power 45 W
loudspeaker effortlessly provides sound quality and performance,
Rated Impedance 330 Ω (330 - 670 - 1300 Ω)
may it be public announcement or background music playback.
Sensitivity (1 m @ 1 W / rated) 88 / 103 dB
The unit utilises a dual cone dynamic 120 mm loudspeaker
Coverage Angle (H x V) 360 °
component which has been treated for waterproofing properties.
The loudspeaker component is enclosed in a compact HIPS Frequency Response 80 Hz ~ 15 kHz

enclosure to withstand harsh outdoor weather conditions, rated to Speaker Component 120 mm Dual cone loudspeaker component,
waterproof treated
IP X4. The unit comes with a built-in audio line matching GD 6
Protection IPX4 (acc. to IEC 529)
transformer for both 100V/70V line distributed speaker systems,
Safety Acc. to EN 60065
rated at 30W.
M a te r ia l & Finish High Impact Polystyrene (HIPS), Mint Green

PD 506 & PD 512 Pendant Loudspeaker


The PD 506 and PD 512 Pendant Loudspeaker is a sphere shaped loudspeaker designed to be mounted directly from the ceiling via its connecting
100V line input cable. The loudspeaker is suitable to be used in high ceiling areas where a false ceiling is not available and mounting ceiling
loudspeaker are prohibitive. The unit is available in 2 colors of either White (PD 506W, PD 512W) or Black (PD 506B, PD 512B), to easily suit
architectural requirements. Each model for PD 506 comes with a built in 100V/70V line matching transformer with 6W and 3W power tapings while
PD 512 comes with a built in 100V/70V line matching transformer with 12W and 6W power tapings.

PD 506W PD 506B PD 512W PD 512B

Technical Specifications
PD 506W PD 506B PD 512W PD 512B

Rated Input 100 V : 6 W (6 – 3 W) 100 V : 6 W (6 – 3 W) 100 V : 12 W (12 – 6 W) 100 V : 12 W (12 – 6 W)


70 V : 3 W (3 – 1.5 W) 70 V : 3 W (3 – 1.5 W) 70 V : 6 W (6 – 3 W) 70 V : 6 W (6 – 3 W)

Maximum Power 9W 9W 18 W 18 W

Rated Impedance 1.7 kΩ (1.7 – 3.3 kΩ) 1.7 kΩ (1.7 – 3.3 kΩ) 0.83 kΩ (0.83 – 1.7 kΩ) 0.83 kΩ (0.83 – 1.7 kΩ)

Sensitivity ( 1 W / rated at 1m ) 90 / 98 dB 90 / 98 dB 90 / 101 dB 90 / 101 dB

Coverage Angle ( 1 kHz, -6 dB ) 180° 180° 220° 220°

Frequency Response 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz 130 Hz ~ 16 kHz

Speaker Component 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker

Material & Finish ABS; White ABS; Black ABS; White ABS; Black

RH Series ABS Paging Horn Loudspeaker


The RH Series is suited for applications in areas with
high ambient noise such as basement carparks, open Technical Specifications

air theme parks or in heavy machinery rooms. The RH RH 082 RH 113


Rated Input 100 V : 20 W (20 - 10 - 5 W) 100 V : 30 W (30 - 15 - 7.5 W)
Series ABS paging horn loudspeakers provide an 70 V : 10 W (10 - 5 - 2.5 W) 70 V : 15 W (15 - 7.5 - 3.8 W)
excellent solution to speech reproduction and sound Maximum Power (100 V) 30 W 45 W
RH 082 distribution in such conditions. Constructed from high Rated Impedance 500 Ω (500 - 1k - 2k Ω) 330 Ω (330 - 667 - 1.3k Ω)
impact ABS, the units are strong but lightweight and Sensitivity 113/125 dB 115/130 dB
resistant to corrosion and UV light. They are dust (1W / rated at 1m)

and water protected to IP 65 (IEC 529), thus ideal for Coverage Angle 165° 160°
(1 kHz, -6 dB)
outdoor applications with harsh environmental
Frequency Response 280 Hz ~ 12.5 kHz 250 Hz ~ 10 kHz
conditions. Available in two different models, the
Safety Acc. to EN 60065 Acc. to EN 60065
models are transformerised for 70V/100V line
Dust & Water Protection IP65 (acc. to IEC 529) IP65 (acc. to IEC 529)
distributed speaker system and comes with a swivel
RH 113 mounting bracket for final positioning adjustment.

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
24
Loudspeakers

PLS Series Projector Loudspeaker


The use of ordinary PA loudspeaker in places with high ambient noise such as in basement carparks, open air theme parks or in heavy machinery rooms
proves to be insufficient to cut through the severe acoustic condition to get the message across to the listener. The PLS Series Projector Loudspeakers
provide an excellent solution to speech reproduction and sound distribution in such conditions. Constructed from high impact ABS, the units are strong
but lightweight and resistant to corrosion and UV light. They are dust and water protected to IP65 (in accordance to IEC 529), thus ideal for outdoor
applications with harsh environmental conditions. The PLS Series Projector Loudspeaker is transformerised for 100 V / 70 V line distributed loudspeaker
system and come with a swivel mounting bracket for final positioning adjustment.
Technical Specifications

PLS 610 PLS 630


Rated Input 100 V : 10 W (10 - 5 - 2.5 W) 100 V : 30 W (30 - 15 - 7.5 W)

PLS 610 Maximum Power 15 W 45 W

Rated Impedance 1 KΩ (1 - 2 - 4 KΩ) 330 Ω (330 - 670 - 1300 Ω)

Sensitivity ( 1 W / rated at 1m ) 92 / 102 dB 92 / 106 dB

Coverage Angle ( 1 kHz, -6 dB ) 180° 180°

Frequency Response 150 Hz ~ 15 kHz 100 Hz ~ 16 kHz

Speaker Component 120 mm Dynamic Full Range Loudspeaker 120 mm Dynamic Full Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065

PLS 630 Material & Finish ABS; White ABS; White

Dimensions Ф138×205 mm Ф161×240 mm

Weight 1.60 Kg 1.75 Kg

VA Series Aluminium Column Loudspeaker


VA 450 The
TheVAVASeries
Seriesarearethetheideal
idealloudspeakers
loudspeakerswhere wheresound
soundprojection
projectionis isnecessary
necessarydue dueto toreverberant
reverberant
VA 450W
conditions.
conditions.The Theloudspeakers
loudspeakersare aredesigned
designedto tohave
havewidewidehorizontal
horizontalangle
angleto toincrease
increasecoverage
coveragearea
area
while
whileitsitsnarrow
narrowvertical
verticalangle
angleto toincrease
increasedirectivity.
directivity.The
TheVAVASeries
Seriesareareconstructed
constructedfromfromdie-casted
die-casted
and
andextruded
extrudedaluminium
aluminiumforfordurability
durabilityandandaesthetic
aestheticappeal.
appeal.AllAllmodels
modelsare aresupplied
suppliedwith
withmatching
matching
transformer
transformer to to
cater
caterforfor
both
both70V70Vandand100V
100Vline. The
line. VAVA
The Series consists
Series consists of of
sixsix
models:
models:VAVA415,
415,VAVA415W,
415W,
VA 430 VAVA430, VAVA430W, VAVA 450 and VAVA450W. Each model is is
different byby
the rated power input. Three models
430, 430W, 450 and 450W. Each model different the rated power input. Three models
VA 430W
are
areavailable
available(VA (VA415W,
415W,VAVA430W 430Wand andVAVA450W)
450W)forforoutdoor
outdoorapplications
applicationswhichwhichcould
couldwithstand
withstand
prolonged
prolonged exposure
exposure to to
rain, heat
rain, heatandandUV.
UV.
Technical Specifications

VA 415 / VA 415W VA 430 / VA 430W VA 450 / VA 450W


VA 415
VA 415W Rated Input (100 V) 15 W (15 - 7.5 - 3.8 W) 30 W (30 - 15 - 7.5 W) 50 W (50 - 25 - 12.5 W)

Rated Input (70 V) 7.5 W (7.5 - 3.8 - 1.9 W) 15 W (15 - 7.5 - 3.8 W) 25 W (25 - 12.5 - 6.3 W)

Rated Impedance 670 Ω (670 - 1330 - 2700 Ω) 330 Ω (330 - 670 - 1330 Ω) 200 Ω (200 - 400 - 800 Ω)

Sensitivity (1 W / rated at 1 m) 90 / 102 dB 92 / 107 dB 93 / 110 dB

Frequency Response 85 Hz ~ 15 kHz 80 Hz ~ 17 kHz 75 Hz ~ 20 kHz

Distribution Pattern 164˚ (H) x 87˚ (V) 155˚ (H) x 64˚ (V) 186˚ (H) x 46˚ (V)

Speaker Component 2 nos. 100 mm Full Range 4 nos. 10 mm Full Range 6 nos. 100 mm Full Range

Safety Acc. to EN 60065 Acc. to EN 60065 Acc. to EN 60065

Dust & Water Protection IP65 (acc. to IEC 529) IP65 (acc. to IEC 529) IP65 (acc. to IEC 529)
- Only for VA 415W - Only for VA 430W - Only for VA 450W

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserved
25
Loudspeakers

Surface Mounted Wall Loudspeaker


The WM 563 and WM 512 Surface Mounted Wall Loudspeaker is designed for a wide range of applications. The unit is ideally installed in
areas without a false ceiling such as in stairwells and rooms with concrete ceiling. Utilising a 120 mm dynamic full range loudspeaker
component, the WM 563 and WM 512 provides excellent speech and music reproduction even under high ambient noise conditions. Its
vented enclosure is designed to enhance the sound quality of the unit. The unit comes fitted with a fine metal mesh cover at the front baffle
for improved aesthetics and better protection. The WM 563 and WM 512 comes with a multiple tapping line-matching transformer, suitable
for 70V or 100V line distributed speaker system. The loudspeaker can be mounted horizontally or vertically without visible mounting screws
and also tilted for closer sound projection. The enclosure is designed for permanent installation to prevent unauthorised
removal of the unit.

Technical Specifications
WM 563 WM 512
Rated Input 100V : 6 W (6 - 3 - 1.5 W) 100V : 12 W (12 - 6 - 3 W)
WM 563 70V : 3 W (3 - 1.5 - 0.75 W) 70V : 6 W (6 - 3 - 1.5 W)

Maximum Power 9W 18 W

Rated Impedance 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ) 0.83 kΩ (0.83 - 1.7 - 3.3 kΩ)

Sensitivity 90 / 98 dB 93 / 104 dB
(1W / rated at 1 m)

Coverage Angle 70 ° 70 °
(1 kHz, -6 dB)

Frequency Response 180 Hz ~ 17 kHz 180 Hz ~ 17 kHz


WM 512
Speaker Component 120 mm Dynamic Full 120 mm Dynamic Full
Range Loudspeaker Range Loudspeaker

Safety Acc. to EN 60065 Acc. to EN 60065

Surface Mounted Wall Loudspeaker


The WM 561 Wall Loudspeaker is designed to provide public address system solution for a wide range of applications. The unit ideally
installed in areas without false ceiling such as in staircase or rooms with concrete ceilings. A 120 mm dual cone full range transducer is
integrated into the WM 561 providing excellent speech and music reproduction even under high ambient noise conditions. The unit is
constructed from robust ABS enclosure which comes in two finishes of either white or black.

Technical Specifications
WM 561W

Rated Input 100 V : 6 W (6 - 3 - 1.5 W)


70 V : 3 W (3 - 1.5 - 0.75 W)
Maximum Power 9W

Rated Impedance 1.7 kΩ (1.7 - 3.3 - 6.7 kΩ)

Sensitivity 93 / 101 dB
WM 561W (1 W / rated at 1m)
Coverage Angle (1 kHz, -6 dB) 106 °

Frequency Response 120 Hz ~ 20 kHz

Speaker Component 120 mm Dual cone Full Range Loudspeaker

Safety Acc. to EN 60065

www.aexsystem.com
PO - 015 - 01 Technical Alterations Reserve d
26
PO - 015 - 01 Technical Alterations Reserved