HITACHI

HITACHIscrew compressors
screw compressors

High
Highefficiency
efficiencyand
andeasy
easymaintenance
maintenance

7.5∼240kW
7.5∼240kWoil-flooded rotary
oil-flooded screw
rotary compressors
screw compressors
Hitachi supports your production innovation with its
advanced technologies focusing on energy saving.
Since started with 75kW (100HP) piston-type compressors launched in 1911, Hitachi has been acting as a leader of
air compressor industry and providing excellent qualities to the customers.
Our big challenge in recent years is "effective use of energy" to promoting both environmental conservation and
cost saving. In 1993, Hitachi released the world's first variable rotating speed compressors by inverter control,
and subsequently introduced certain flagship products.
Now, we are launching the       2000 Series (7.5kW∼75kW) as the brand-new models to satisfy customers'
relentless demands.
We believe the      2000 Series compressor will be a reliable partner for achieving your advanced
production innovation.

1
model list
Motor output (kW)

series Dryer 2000 series series Page

7.5 11 15 22 37 55 75 100 110 150 125∼240

air- built-in
cooled −
Vplus water- built-in
P3∼6

cooled −
air- built-in
cooled
M-type −
built-in
water-
cooled −
P7∼10
air- built-in
cooled −
S-type built-in
water-
cooled

: conventional V-type : HISCREW 2000 Series

capacity control
Control method S-type M-type Vplus

U-mode (suction throttle valve control) ○ ○ −


I-mode (on-off line control, U-mode is automatically
selected as load fluctuation) ◎ ○ ○
P-mode (motor stop-restart control) − ◎ ○

V-mode (constant discharge pressure control by inverter) − − ◎


◎ : Factory preset mode
Vplus is added PQ wide mode to V-type

2
New line-up with ''PQ wide mode'' ―― Vplus.

Vplus provides variable air capacity upon your requirement by inverter control.
■ Vplus achieves cost saving by ideal air capacity control.

●conventional model ●Vplus 37kW model


1,200rpm
3 3
1.8m /min 11kW 2.0m /min
1,400rpm
3 3
2.4m /min 15kW 2.4m /min
2,250rpm
3 3
3.8m /min 22kW 3.8m /min
3,700rpm
3 3
6.3m /min 37kW 6.3m /min

[At 0.69 MPa]

Reduction of power consumption. Stable discharge pressure.

By the best combination with Hitachi inverters, Vplus achieves With highly accurate discharge pressure control
considerable energy saving with easier maintenance. system, Vplus realises ± 0.01MPa as the
100
maximum fluctuation of pressure. It can supply
air with optimum pressure efficiently.
90

80

70 Approx. Energy-saving effect


Power consumption (%)

38% power savings S-type/M-type


60 0.69
Pressure (MPa)

50

0.59
40
Vplus
stable discharge ±0.01MPa
30 Typical compressors with suction throttle pressure
Typical compressors with suction throttle
20
and on/off line control Time
10 HISCREW 2000 Series
Vplus
0 10 20 30 40 50 60 70 80 90 100
Air consumption (%)

■ Energy Saving (37kW model) ■ Example of 37 kW annual power cost


Advantage :

38% The annual power cost for a compressor


is equivalent to the approximate cost of

Ideal 73%
installing one compressor.

system 200MWh
123MWh
10%
17%

Power cost Maintenance cost Cost of amortizing body


(7-year equal amortization)
(Average air consumption 50% Operating time : 6000h/year) (Power cost for 37-kW class, 6,000-hour annual operation)

3
PQ wide mode ― A unique control mode to widen operable range.
Hitachi's inverter controlling system brings about larger capacity under lower pressure or higher pressure under smaller
capacity. The operable pressure range is from 0.44 to 0.83MPa*, and air capacity is increasing maximum 6-14% compared
with conventional models. (*In case of 22/37kW model)

■ Capacity table (with PQ wide mode) High pressure


3
(m /min) (MPa) ( 22kW/37kW model )
In the case of the
0.83
Pressure conventional model
MPa 0.44 0.49 0.59 0.69 0.83 0.88
Vplus
(0.45) (0.5) (0.6) (0.7) (0.85) (0.9)
Model
7.5kW 1.15 1.15 1.15 1.03 0.96 0.69 Wider
operable

Increase in air
11kW 1.75 1.75 1.75 1.6 1.5
0.59 conventional model range

quantity
15kW 2.4 2.4 2.4 2.1 2.0
(Pressure)

22kW 4.1 4.1 4.1 3.8 3.3


0.49
37kW 6.7 6.7 6.7 6.3 5.5
0.44
55kW 10.0 10.0 9.5 8.5 Low pressure
75kW 13.4 13.4 12.6 10.8

19.0 19.0 18.1 16.7 0 100 106


(%)
100kW
*Pressure for 100kW is indicated in ( ). PQ wide mode area (air consumption)

PQ wide mode enables outstanding cost-saving.


■Outstanding conventional model(22/37kW) (22/37kW)
power-saving 100 100

in wide pressure Typical compressors with


Suction throttle
range. 0.83MPa
80 80
Power consumption (%)

Power consumption (%)

60 60

0.69MPa 0.69MPa
40 40
0.59MPa 0.59MPa
0.49MPa 0.44MPa
20 20

0 20 40 60 80 100 0 20 40 60 80 100 106


Air consumption (%) Air consumption (%)
Operating pressure : max. 0.69MPa, min. 0.49MPa Operating pressure : Extended to max. 0.83MPa, min. 0.44MPa
In a range from 0.69 to 0.49MPa, power-saving efficiency In a range from 0.69 to 0.44MPa, power-saving efficiency
greater than any other control system. greater than any other control system.

■ Comparison of electric energy Unit : MWh Unit : MWh


Motor output Load factor 100 70 50 20 0 Motor output Load factor 100 70 50 20 0
U-type 51 47 43 39 35 U-type 241 216 200 164 157
7.5kW M-type 51 41 33 21 0 37kW M-type 241 195 158 104 0
Vplus 47 35 26 13 0 Vplus 221 162 123 65 0
U-type 73 67 62 55 51 U-type 366 328 300 260 235
11kW M-type 73 59 48 30 0 55kW M-type 366 294 247 168 0
Vplus 68 49 37 19 0 V-type 335 245 185 94 0
U-type 95 86 81 72 67 U-type 476 424 390 339 304
15kW M-type 95 76 61 35 0 75kW M-type 476 380 310 193 0
Vplus 89 63 48 25 0 Vplus 436 313 234 124 0
U-type 143 129 119 103 93 U-type 660 591 545 475 429
22kW M-type 143 115 94 62 0 100kW
Note : U-type
M-type
is commonly used suction throttle valve control.
660 534 443 295 0
Vplus 131 97 73 39 0 Vplus 615 472 353 182 0
Conditions : Operating time : 6,000hr/year
The figures of Vplus from 7.5 to 15kW were calculated under the setting pressure of 0.73MPa.
Those of Vplus from 22 to 100kW were calculated under the setting pressure of 0.59MPa.

Vplus 4
Vplus
Vplus abundant
abundant functions
functions to
to achieve
achieve safety,
safety, stability
stability and
and easy
easy operation
operation

Conservation of discharge pressure Vplus can reduce the charging time.


Conservation of discharge pressure Vplus can reduce the charging time.
Vplus maintains the necessary discharge pressure at all With the PQ wide mode, the charging time can be shorter,
Vplus maintains the necessary discharge pressure at all With the PQ wide mode, the charging time can be shorter,
times with the unique patented intelligent control system, maximum 14% (15kW model).
times with the unique patented intelligent control system, maximum 14% (15kW model).
even in motor stop-restart control.
even in motor stop-restart control.

Constant pressure

MPa
0.83 Constant pressure

pressureMPa
0.83

(Pressure) ︵
(Pressure) 0.69

pressure
(MPa) 0.69
(MPa) At ON
Conservation function of discharge pressure At ON
Conservation function of discharge pressure

Discharge
0.69

Discharge
0.69

At OFF
0 At OFF
0
86% 14% Pressure-rise time
86%
100% 14% Pressure-rise time
0.59
0.59
100%
Constant pressure
Constantarea
control pressure
control area
Pressure decrease (Conventional Pressure setting is easy to change.
Pressure decrease
variable speed (Conventional
control model)
variable speed control model)
Pressure setting is easy to change.
Even with a compressor load, it is possible to change the
Even with a compressor load, it is possible to change the
Pressure setting.
Pressure setting.
You can decide whether or not to apply PQ
You can decide whether or not to apply PQ
wide mode by using the panel switch.
wide mode by using the panel switch. Control pressure indication
Control pressure indication

●Capacity priority Priority on air quantity Control pressure key-in


●Capacity priority Priority on air quantity Control pressure key-in
(PQ wide mode on)
(PQ wide mode on)
100
(%)(%)

100
Pa
9M a
0.669MPPa Higher response and stability with Hitachi’s
consumption

1
90
Higher response and stability with Hitachi’s
consumption

2
0. .59MPa
1
90 2
0 9M a
0.5 4MPa original sensorless vector and PID control.
PQ wide mode 80
80 0.44MP original sensorless vector and PID control.
PQ wide mode 0.4
Power

We have developed our own system that can control


ON
Power

We have developed our own system that can control


ON 70
70 80 90 100 Air quantity (%) discharge pressure within ± 0.01MPa.
80 90 100 Air quantity (%) discharge pressure within ± 0.01MPa.
(1) Power consumption becomes approx. 92% when the discharge pressure decreases
(1) Power consumption
from 0.69MPa becomes approx. 92% when the discharge pressure decreases
to 0.59MPa.
from 0.69MPa to 0.59MPa.
Automatic restart function
(2) Using the power remaining after pressure decrease, capacity can be increased up
Using
(2) to theInpower
106%. remaining
that case, after consumption
the power pressure decrease,
becomescapacity
100%.can be increased up
Automatic restart function
to 106%. In that case, the power consumption becomes 100%. In the case of blackouts within 5 seconds, HISCREW is
In the case of blackouts within 5 seconds, HISCREW is
capable of restarting. (Except the S-type)
capable of restarting. (Except the S-type)
●Energy-saving priority Priority on reducing power consumption
●Energy-saving priority Priority on reducing power consumption
(PQ wide mode off)
(PQ wide mode off) 100
Retry function
(%)(%)

100
Retry function
1
Pa
9M a
1
consumption

90
0.669MPPa When an inverter-trip occurs, HISCREW runs the restart
consumption

2
90
0..59MPa 2 When an inverter-trip occurs, HISCREW runs the restart
0 9M Pa program up to 3 times.
80 00..549MPa program up to 3 times.
PQ wide mode M
0.49
80
PQ wide mode
Power

OFF
Power

OFF 70
70 80 90 100 Air quantity (%)
80 90 100 Air quantity (%)
Built-in DC reactor
(1) Power consumption automatically becomes approx. 92% when the discharge Built-in DC reactor
(1) Power
pressureconsumption automatically
decreases from 0.69MPa to becomes
0.59MPa. approx. 92% when the discharge Built-in DC reactor inhibits the harmonic component by the
pressure decreases from 0.69MPa to 0.59MPa. Built-in DC reactor inhibits the harmonic component by the
inverter.
(2) If the discharge pressure decreases to 0.49 MPa, power consumption automatically inverter.
If the discharge
(2) becomes approx.pressure
86%. decreases to 0.49 MPa, power consumption automatically
becomes approx. 86%.

Built-in contactor
Built-in contactor
Electromagnetic contactor protects the inverter.
Electromagnetic contactor protects the inverter.

5
STANDARD
STANDARD SPECIFICATIONS
SPECIFICATIONS

Air-cooled
Air-cooled Vplus
Vplus [Without
[Without dryer
dryer and
and Dryer
Dryer built-in
built-in model]
model] ( )Dryer equipped.
( )Dryer equipped.
Model OSP-22V5A OSP-37V5A OSP-55V5A OSP-75V5AL
Model OSP-7.5VA OSP-15VA (R)Ⅱ
OSP-22V5A(R)Ⅱ (R)Ⅱ
OSP-37V5A(R)Ⅱ (R)Ⅰ
OSP-55V5A(R)Ⅰ (R)
OSP-75V5AL( R)Ⅰ
Ⅰ OSP-100V5ALⅠ
OSP-100V5ALⅠ
(R)Ⅲ
OSP-7.5VA(R)Ⅲ OSP-11VA(R)Ⅲ
OSP-11VA(R)Ⅲ (R)Ⅲ
OSP-15VA(R)Ⅲ OSP-22V6A OSP-37V6A OSP-55V6A OSP-75V6AL
Item
Item (R)Ⅱ
OSP-22V6A(R)Ⅱ (R)Ⅱ
OSP-37V6A(R)Ⅱ (R)Ⅰ
OSP-55V6A(R)Ⅰ (R)
OSP-75V6AL( R)Ⅰ
Ⅰ OSP-100V6ALⅠ
OSP-100V6ALⅠ
Motor 7.5 11 37 55 75 100
Motor output
output kW
kW 7.5 11 15
15 22
22 37 55 75 100
Discharge pressure MPa 0.83    
  0.69 0.7
0.7
Rated
Rated Discharge pressure MPa 0.83   0.69
specs
specs Capacity 3
1.03 1.6 2.1 3.8 6.3 9.5 12.6 18.1
Capacity m
m /min
3
/min 1.03 1.6 2.1 3.8 6.3 9.5 12.6 18.1
Discharge pressure MPa 0.69 0.88 0.69
0.69 0.88
0.88 0.69
0.69 0.88 0.59 0.83
0.83 0.59 0.83 0.59 0.83
0.83 0.59 0.83
0.83 0.6 0.85
0.85
In Discharge pressure MPa 0.69 0.88 0.88 0.59 0.59 0.83 0.59 0.59 0.6
In PQ
PQ
wide mode
mode Capacity m
3
1.15 0.96 1.75 1.5 2.4 2.0 4.1 3.3 6.7 5.5 10 8.5 13.4 10.8 19.0 16.7
wide Capacity m /min 1.75 1.5 2.4 3.3 8.5 10.8 16.7
3
/min 1.15 0.96 2.0 4.1 6.7 5.5 10 13.4 19.0
Setting
Setting range
range of
of pressure
pressure MPa 0.49∼0.88 0.44∼0.83 0.49∼0.83 0.5∼0.85
MPa 0.49∼0.88 0.44∼0.83 0.49∼0.83 0.5∼0.85
Operating range
Operating range of
of PQ
PQ wide
wide mode
mode MPa 0.69∼0.88 0.59∼0.83 0.6∼0.85
MPa 0.69∼0.88 0.59∼0.83 0.6∼0.85
Intake
Intake air
air press./temp.
press./temp. ― Ambient pressure / 0∼40˚C (5∼40˚C)
― Ambient pressure / 0∼40˚C (5∼40˚C)
Discharge temperature
temperature Suction
Suction temperature
temperature + 15
15 or
or lower
˚C +
Discharge ˚C lower
  2-pole
Driving  
― 2-pole TEFC
TEFC motor
motor
Driving method
method ― 4-pole
4-pole TEFC
TEFC motor
motor V-belt
V-belt drive.
drive. Inverter
Inverter control
control gear
gear drive
drive
Starting
Starting method
method ― Inverter
Inverter

NEW HISCREW OIL 2000 25 NEW HISCREW OIL 2000 33 NEW HISCREW OIL 2000 48
Lubricating 5 6 77 88 NEW HISCREW OIL 2000 13 NEW HISCREW OIL 2000 25 NEW HISCREW OIL 2000 33 NEW HISCREW OIL 2000 48
Lubricating oil
oil capacity L NEW HISCREW OIL 2000 NEW HISCREW OIL 2000 NEW HISCREW OIL 2000 NEW HISCREW OIL 2000
capacity L NEW HISCREW OIL 2000 5 NEW HISCREW OIL 2000 6 NEW HISCREW OIL 2000 NEW HISCREW OIL 2000 NEW HISCREW OIL 2000 13 [not
[not filled]
filled] [not
[not filled]
filled] [not
[not filled]
filled]
10 ―
Dew
Dew point
point of
of outlet
outlet air
air ˚C
˚C 10 Under
Under pressure
pressure ―
Dryer

kW 0.3 0.5 ―
Dryer

Rated motor
motor output
output kW 0.3 0.5 1.1
1.1 2.2 3.0 ―
Rated 2.2 3.0
― HFC-R407C/Capillary ―
Refrigerant/control
Refrigerant/control system
system ― HFC-R407C/Capillary tube
tube ―
2 [ ]
Dischage
Dischage pipe
pipe diameter
diameter
B
B Rc3/4
Rc3/4 Rc1
Rc1 11 11 1/2
1/2 11 1/2
1/2 [Flange]]
22 [Flange 2 1/2[Flange
1/2 Flange]
Dimensions (W×D×H)
(W×D×H) mm 840×710×1,075 930×770×1,200 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Dimensions mm 840×710×1,075 930×770×1,200 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
820(890)
820( 1,070 1,500( 1,670) 2,400
Weight
Weight
kg
kg
285(310)
285( 310) 335(365)
335( 365) 350(380)
350( 380) 570(620)
570( 620) 890) (1,190)
1,070( 1,190) 1,500 (1,670) 2,400
Noise level
level (at dB 53 55 56 57 60 66 69 72
Noise (at 1.5m
1.5m in
in front)
front) [A]
dB[A] 53 55 56 57 60 66 69 72

Water-cooled
Water-cooled Vplus/
Vplus/ V-type
V-type [Without
[Without dryer
dryer and
and Dryer
Dryer built-in
built-in model]
model] ( )Dryer equipped.
( )Dryer equipped.
Model
Model OSP-22VW(R)Ⅰ
OSP-22VW(R)Ⅰ OSP-37VW(R)Ⅰ
OSP-37VW(R)Ⅰ OSP-55VW(R)Ⅰ
OSP-55VW(R)Ⅰ OSP-75VWL(R)
OSP-75VWL( R)Ⅰ
Ⅰ OSP-100VWLⅠ
OSP-100VWLⅠ
Item
Item
Motor
Motor output
output kW 22 37 55 75 100
kW 22 37 55 75 100
0.69 [ ] 0.69
Rated
Rated
Discharge pressure MPa
Discharge pressure MPa 0.69 [0.83
0.83]    
    0.69 0.7
0.7
specs Capacity
3
[ ]] 6.3 [ ]] 9.5 12.6 18.1
specs m
m /min
3.8
3.8 [3.3 6.3 [5.5
3
Capacity /min 3.3 5.5 9.5 12.6 18.1
Discharge pressure
Discharge pressure MPa 0.59
0.59 0.83
0.83 0.59 0.83 0.6 0.85
In 0.59 0.83 0.6 0.85
In PQ
PQ MPa
wide
wide mode
mode Capacity m
3
10 8.5 13.4 10.8 19.0 16.7
Capacity m /min
3
/min 10 8.5 13.4 10.8 19.0 16.7
Setting [ ] 0.49∼0.83
Setting range
range of
of pressure
pressure MPa
MPa
0.49∼0.69
0.49∼0.69 [0.49∼0.69
0.49∼0.69] 0.49∼0.83 0.5∼0.85
0.5∼0.85
Operating range
range of
of PQ
PQ wide
wide mode MPa 0.59∼0.83
0.59∼0.83 0.6∼0.85
Operating mode MPa 0.6∼0.85
Intake
Intake air
air press./temp. Ambient
press./temp. ―
― Ambient pressure
pressure // 0∼40˚C
0∼40˚C (5∼40˚C)
(5∼40˚C)
Discharge temperature
Discharge temperature ˚C Cooling water
water temperature
temperature + 13˚C or
or lower
lower
˚C Cooling + 13˚C
Driving
Driving method 4-pole
method ―
― 4-pole TEFC
TEFC motor
motor V-belt
V-belt drive.
drive. Inverter
Inverter control
control 2-pole
2-pole TEFC
TEFC motor
motor gear
gear drive
drive
Starting
Starting method
method ― Inverter
Inverter

Lubricating
Lubricating oil
oil capacity 8 13 25
capacity L
L
NEW HISCREW OIL 2000
NEW HISCREW OIL 2000 8 NEW HISCREW OIL 2000
NEW HISCREW OIL 2000 13 NEW HISCREW OIL 2000
NEW HISCREW OIL 2000 25 [not
[not filled]
filled] NEW HISCREW OIL 2000 33 [not filled] NEW HISCREW OIL 2000 48 [not filled]
NEW HISCREW OIL 2000 33 [not filled] NEW HISCREW OIL 2000 48 [not filled]

Cooling Temperature
Temperature ˚C 32
32 or
or lower
lower
Cooling ˚C
water
water Quantity
Quantity L/min 45 65
65 100
100 100
100 125
125
L/min 45
Dew 10
10 Under
Under pressure
Dew point
point of
of outlet
outlet air
air ˚C
˚C pressure ―

Dryer
Dryer

Rated motor
Rated motor output
output kW 1.1 2.2 3.0 ―
kW 1.1 2.2 3.0 ―
Refrigerant/control HFC-R407C/Capillary
HFC-R407C/Capillary tube
Refrigerant/control system
system ―
― tube ―

Dischage B 1 11 1/2 11 1/2 22 [[Flange ] [ ]
Dischage pipe
pipe diameter
diameter B 1 1/2 1/2 Flange] 22 1/2
1/2[Flange
Flange]
Dimensions mm 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Dimensions (W×D×H)
(W×D×H) mm 1,200×890×1,260
1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Weight kg 940 1,100( 1,220)
Weight kg 570(620)
570( 620) (1,010)
940( 1,010) 1,100(1,220) 1,540(1,710)
1,540( 1,710) 2,300
2,300
Noise dB 57 60 65
Noise level
level (at
(at 1.5m
1.5m in
in front)
front) dB[A]
[A] 57 60 65 66
66 69
69
Notes :
Notes :
1. Capacity is the converted value at its inlet condition.
1. Capacity is the converted value at its inlet condition.
2. Noise level is the value at 1.5m in front and 1m height in an anechoic room.
2. Noise level is the value at 1.5m in front and 1m height in an anechoic room.
3. Dew point measured at ambient temperature 30˚C and rated discharge pressure.
3. Dew point measured at ambient temperature 30˚C and rated discharge pressure.
4. Using PQ wide mode, dew point change by discharge pressure.
4. Using PQ wide mode, dew point change by discharge pressure.
5. A unit is shipped without a selected earth leakage breaker.
5. A unit is shipped without a selected earth leakage breaker.
6. A unit is shipped without oil (55kW and above).
6. A unit is shipped without oil (55kW and above).
7. A properly sized receiver is necessary for energy saving.
7. A properly sized receiver is necessary for energy saving.
8. Specifications may be changed without notice.
8. Specifications may be changed without notice.

Vplus
Vplus 6
6
High
High efficiency
efficiency by
by ECOPROFILE
ECOPROFILE conventional
conventional model
model
5% (m3/min)
(m 3
/min)
5%
increased
We
We have
have developed
developed a a new
new increased
15
15
optimal rotor
optimal rotor profile,
profile,
ECOPROFILE, for
ECOPROFILE, for the
the 3%
3%
HISCREW 2000 2000 series
series through
through increased
increased
HISCREW 22
simulations of of more
more than
than 2000
2000 22
simulations
kinds of
kinds of rotor
rotor profile
profile patterns.
patterns. 5%
5%
Using High
High performance
performance realized
realized by
increased
increased
Using ECOPROFILE,
ECOPROFILE, efficiency
efficiency newly
by
is newly developed
developed rotor
rotor 55
55
is increased from
increased from approximately
approximately
3 *
3 to
to 5%.
5%.*

*compared
compared with
with conventional
conventional model.
model.

High
High efficiency
efficiency by
by unique
unique capacity
capacity control
control

■ Example
Example of
of 37
37 kW
kW annual
annual electric
electric energy
energy
Approx. (Average
100
Approx. (Average air
air consumption
consumption 50%)
50%)
100 21% power
21% power savings
savings
90
90

80
80

70
70
(%)

200MWh
consumption(%)

60 200MWh 158MWh
158MWh
60
Powerconsumption

50
50

40 (6,000hour
(6,000hour operation/year)
operation/year)
40
Power

typical
typical compressors
compressors with
with suction
suction throttle
throttle
30
30
typical Typical
Typical compressors
compressors with
with
typical compressors
compressors with
with suction
suction throttle
throttle suction
and suction throttle
throttle and
and
and on-off
on-off line
line control
20
20 control on-off
on-off line
line control
control 2000
2000 Series
Series
10
10 S-type
S-type M-type
M-type When
When ECOMODE
ECOMODE isis used
used
(S-type) Compared
Compared with
with typical
typical ones
ones with
with aa suction
suction throttle
throttle and
and

42MWh
(S-type)
one-off line
one-off line control,
control, the
the HISCREW
HISCREW compressor
compressor reduces
reduces
0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40
Air
50 60 70 80 90 100 power
power consumption
consumption by by approximately
approximately 21%.
21%. For
For 37kW
37kW :: MWh
Air consumption
consumption (%)
(%) example,
example, in
in the
the case
case of
of aa 50%
50% decrease
decrease inin air
air quantity
quantity
used,
used, the
the difference
difference in
in annual
annual power
power consumption
consumption is:is:
(Install an air tank for energy-saving.)
(Install an air tank for energy-saving.)

ECOMODE
ECOMODE function
function as
as standard
standard equipment
equipment
●Using High-limit
High-limit pressure
pressure lowered
lowered automatically
●Using ECOMODE,
ECOMODE, maximum
maximum pressure
pressure is
is automatically
automatically ↓ High-limit
High-limit pressure
pressure
automatically
reduced
↓ (Unload
(Unload start
start pressure)
reduced with load fluctuations, so approx. 3%
with load fluctuations, so approx. 3% power
power pressure)
pressure
Linepressure

saving can
saving can be
be achieved.
achieved.
ECOMODE setting
ECOMODE setting is
is easy;
easy; you
you need
need only
only push
push the
the switch
switch Low-limit
Low-limit pressure
pressure
Line

on the
on the control
control panel.
panel. (Load
(Load reset
reset pressure)
pressure)
Load Unload Time→
Time→
Load Unload
Energy-saving
Energy-saving effect:
effect: Approx.
Approx. 3%
3% max.
max.

Easy
Easy operation
operation More
More reliable
reliable lubricating
lubricating oil
oil
●Varied
●Varied settings,
settings, pressure,
pressure, ECOMODE
ECOMODE function,
function, remote
remote After
After testing
testing 2000
2000 blends
blends of of oil,
oil, we
we developed
developed
operation
operation and all, can be changed easily on
and all, can be changed easily on the
the control
control a
a new type of synthetic oil for the HISCREW
new type of synthetic oil for the HISCREW
panel.
panel. 2000
2000 series.
series.
The
The new
new oil
oil has
has long
long life,
life, so
so the
the oil
oil change
change

  cycle
cycle is two years. Initial ration is 20%
is two years. Initial ration is 20% less
less

  than
than conventional
conventional model.
model.

7
7
Easy maintenance
1. Dryer
●New structure
Dryer uses an environment-friendly
Compact and easy to maintain
refrigerant, HFC-R407C.
1 2 ●8-year overhaul interval
2. Maintenance cooler
The combination of high load type
If only the right side panel is
bearing and high-precision
removed, the air-cooled cooler can
lubricating oil filtration system
be cleaned.
allows an 8-year overhaul interval.
(75kW, 100kW model is not included)
3. V-ribbed belt
Equipped with a
●General hermetic motor
new, more durable
High reliability and easy maintenance
belt.
4
●Daily check
4. Spin on type
All items in the daily checks can be
3 oil separator
performed by removing the front
Easy maintenance.
5 panel.

5. Cooling fan operates with


the main motor (7.5∼15kW
Vplus)

Systematic upgrade
Hitachi HISCREW 2000 series (Vplus, M-type and S-type) share Advantages
a common design and parts. Our original way of systematic
upgrade, in which Vplus plays a central role, have a lead as a 1 The combination system demonstrates almost the same
whole. characteristics in power consumption as a Vplus of 75kW.
2 Approx. 25% reduction in initial investment.
V-M combination system 3 Approx. 44% reduction in electric power cost at the used
air ratio of 60% when the pressure if 0.59MPa.
● Hitachi’s V-M combination system would be the most
appropriate as a system of 2 to 3 compressors because of
our original common design.
M-type
● V-M combination system brings certain advantages
described below.

Vplus 37kW M-type 37kW


100
Power consumption ratio (%)

200
Initial investment (%)

25%
Conventional model of
Suction throttle
75kW 50 V-type M-type valve control Vplus
100

Vplus
Vplus M-type
0 0
75kW Vplus 37kW VM 100 200
Single-V, Multi-V system combination Used air ratio (%)
※Compared amount without dryer models.

● Can save energy by varied combination

    Mtype / Stype 8
Optional Specifications

Improved operationality Dual operation


■Digitalized pressure, temperature, electric current ■Mere wiring enables alternating or follow-up operation.
and other setup are displayed in characters. Wiring between 2 units of HG version enables alternate and lead log operation such
Detailed setup of remote operation and momentary power as V-M combination operation, 2 M-type and Dual V operations with no external
failure are also possible in accordance with usage condition. control panel. In V-M combination operation, if the amount of used air becomes 0, the
V-type will stop
Failure indicator lump Operational status automatically. wiring operation/stop Air tank
indicator lump load/unload
In addition, you can M-type
improve the
operationality further
by combining with
other equipment.
Primary functions
Energy saving operation, scheduled operation, alternating or follow-up operation (in parallel or interval change-over), communication function,
LCD monitor Setup switch area Power lump Operation Stop switch maintenance time notification, storing operational and load data, timely switching of pressure setup, switching of external pressure setup, etc.
switch Contents displayed on the monitor
Total operation time, discharge pressure, load factor, the number of loading, electric current, total loading time, detailed failure history, etc.
Only Vplus displays motor output and frequency, and inverter failure history.

Note :
1. HG Version is applicable only to 22 - 75kW, for both Vplus and M-type of HISCREW2000 series. 2. Both of two compressors must be HG Version to use the alternating or follow-up function.
3. In order to use the alternating or follow-up function, separate wiring works are necessary. (Prepare the connecting cable at the expense of customer since it does not come with this equipment.)
4. In order to use the communication function, separate remote supervisory system (COSMOS) and wiring works are necessary. (Prepare the communication cable at the expense of customer since it does not come with this equipment.)

Care for environment protection ■Specifications


Target equipment Dedicated to 11 to 75kW dryer built-in type HISCREW2000 series
■Neither additional piping work nor Processing method / oil content level after the processing Oil absorbent filtration / 5 mg/L or less (extractive substance in normal-hexane)
space is necessary. Discharge method of purified water Solenoid valve with timer
Suitable compressors specified pressure MAX. 0.92MPa
ECOSEP maintains the oil Working temperature 5∼40℃
Power source AC200/200・220V (50/60Hz) [self-support]
concentration level in the drain at
Drainage diameter Rc 3/8
5 mg/L or less. The number of element tanks 1(11∼37kW) 2(55∼75kW)
3,000h (22/75kW)
Operating life of the element tank 6,000h (15kW)
9,000h (11kW)

Notes :
1. Since ECOSEP is for exclusive use of dryer built-in type HISCREW2000 series, drain water discharged
from other machines cannot be processed.
2. The expected concentration level of oil content is not a guaranteed value.
3. ''Extractive substance in normal-hexane" means the mass of residue after having hexane emitted at 80℃
Drain of usual Drain processed by where the hexane is used to extract from slightly acidified specimen.
compressor ECOSEP 4. The replacement interval of the element tank should be referred to as a rough standard, since their
installed environment could shorten the operating life of each element tank.
5. Since water-pollution standards differ according to regions and areas of water, ask administrative
agencies in charge about the details.

(can be connected to HG version)

Remote monitoring system of Hitachi air compressors


(LAN: Local Area Network)
■Integrating IT with the compressor ensures easy monitoring. Central administration by an existing PC on your LAN is possible.
●Real-time monitoring of functions, setup and operational ●Perfect fit for monitoring the plural units control or compressors
status of the compressor from your office contributes to labor which were put into distributed places.
and energy saving. RS485 Multi-dropped connection
●Monitoring through Web on your existing PC does not require Remote monitoring system
COSMOS
any additional installation of particular software.
●Such upgrading as to widened monitoring through the M-type
Internet and/or maintenance system is possible.
LAN access or direct hookup
Office Compressor room

9
STANDARD
STANDARD SPECIFICATIONS
SPECIFICATIONS

Air-cooled M-type/ S-type [Without dryer and Dryer built-in model] ( )Dryer equipped.
Air-cooled M-type/ S-type [Without dryer and Dryer built-in model] ( )Dryer equipped.
Model OSP-15S5A(R)Ⅱ OSP-22S5A(R)Ⅰ OSP-37S5A(R)Ⅰ OSP-55S5A(R)Ⅰ OSP-75S5AL(R)Ⅰ OSP-100S5ALⅠ OSP-110S5ALⅠ
Model S-type ― ― OSP-15S5A(R)Ⅱ OSP-22S5A(R)Ⅰ OSP-37S5A(R)Ⅰ OSP-55S5A(R)Ⅰ OSP-75S5AL(R)Ⅰ OSP-100S5ALⅠ OSP-110S5ALⅠ
S-type ― ― OSP-15S6A(R)Ⅱ OSP-22S6A(R)Ⅰ OSP-37S6A(R)Ⅰ OSP-55S6A(R)Ⅰ OSP-75S6AL(R)Ⅰ OSP-100S6ALⅠ OSP-110S6ALⅠ
OSP-15S6A(R)Ⅱ OSP-22S6A(R)Ⅰ OSP-37S6A(R)Ⅰ OSP-55S6A(R)Ⅰ OSP-75S6AL(R)Ⅰ OSP-100S6ALⅠ OSP-110S6ALⅠ
OSP-7.5M5A(R)Ⅱ OSP-11M5A(R)Ⅱ OSP-15M5A(R)Ⅱ OSP-22M5A(R)Ⅰ OSP-37M5A(R)Ⅰ OSP-55M5A(R)Ⅰ OSP-75M5AL(R)Ⅰ OSP-100M5ALⅠ OSP-110M5ALⅠ
M-type OSP-7.5M5A(R)Ⅱ OSP-11M5A(R)Ⅱ OSP-15M5A(R)Ⅱ OSP-22M5A(R)Ⅰ OSP-37M5A(R)Ⅰ OSP-55M5A(R)Ⅰ OSP-75M5AL(R)Ⅰ OSP-100M5ALⅠ OSP-110M5ALⅠ
Item M-type OSP-7.5M6A(R)Ⅱ OSP-11M6A(R)Ⅱ OSP-15M6A(R)Ⅱ OSP-22M6A(R)Ⅰ OSP-37M6A(R)Ⅰ OSP-55M6A(R)Ⅰ OSP-75M6AL(R)Ⅰ OSP-100M6ALⅠ OSP-110M6ALⅠ
Item OSP-7.5M6A(R)Ⅱ OSP-11M6A(R)Ⅱ OSP-15M6A(R)Ⅱ OSP-22M6A(R)Ⅰ OSP-37M6A(R)Ⅰ OSP-55M6A(R)Ⅰ OSP-75M6AL(R)Ⅰ OSP-100M6ALⅠ OSP-110M6ALⅠ
Motor output kW 7.5 11 15 22 37 55 75 100 110
Motor output kW 7.5 11 15 22 37 55 75 100 110
3
Capacity m3/min 1.03 [1.15] 1.6 [1.75] 2.1 [2.4]  3.8 [3.3]  6.3 [5.5] 9.5 [8.5] 12.6 [10.8] 18.1[16.7] 20[18]
Capacity m /min 1.03 [1.15] 1.6 [1.75] 2.1 [2.4]  3.8 [3.3]  6.3 [5.5] 9.5 [8.5] 12.6 [10.8] 18.1[16.7] 20[18]
Intake air press./temp. ― Ambient pressure / 0∼40˚C (5∼40˚C)
Intake air press./temp. ― Ambient pressure / 0∼40˚C (5∼40˚C)
Discharge pressure MPa 0.83 [0.69] 0.69 [0.83] 0.75 [0.85]
Discharge pressure MPa 0.83 [0.69] 0.69 [0.83] 0.75 [0.85]
Discharge temperature ˚C Suction temperature + 15 or lower
Discharge temperature ˚C Suction temperature + 15 or lower
Driving method ― 4-pole TEFC motor V-belt drive 2-pole TEFC motor gear drive
Driving method ― 4-pole TEFC motor V-belt drive 2-pole TEFC motor gear drive
Starting method ― Full voltage start Star-delta [3 contactors]
Starting method ― Full voltage start Star-delta [3 contactors]
NEW HISCREW OIL 2000 25 NEW HISCREW OIL 2000 33 NEW HISCREW OIL 2000 48 NEW HISCREW OIL 2000 53
Lubricating oil capacity L NEW HISCREW OIL 2000 5 NEW HISCREW OIL 2000 6 NEW HISCREW OIL 2000 7 NEW HISCREW OIL 2000 8 NEW HISCREW OIL 2000 13 NEW HISCREW OIL 2000 25 NEW HISCREW OIL 2000 33 NEW HISCREW OIL 2000 48 NEW HISCREW OIL 2000 53
Lubricating oil capacity L NEW HISCREW OIL 2000 5 NEW HISCREW OIL 2000 6 NEW HISCREW OIL 2000 7 NEW HISCREW OIL 2000 8 NEW HISCREW OIL 2000 13 [not filled] [not filled] [not filled] [not filled]
[not filled] [not filled] [not filled] [not filled]
Dew point of outlet air ˚C 10 Under pressure ―
Dew point of outlet air ˚C 10 Under pressure ―
Dryer

Rated motor output kW 0.3 0.5 1.1 2.2 3.0 ―


Dryer

Rated motor output kW 0.3 0.5 1.1 2.2 3.0 ―


Refrigerant/control system ― HFC-R407C/Capillary tube ―
Refrigerant/control system ― HFC-R407C/Capillary tube ―
Dischage pipe diameter B Rc 3/4 Rc1 1 1 1/2 2 [Flange] 2 1/2 [Flange]
Dischage pipe diameter B Rc 3/4 Rc1 1 1 1/2 2 [Flange] 2 1/2 [Flange]
Dimensions (W×D×H) mm 840×710×1,075 930×770×1,200 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Dimensions (W×D×H) mm 840×710×1,075 930×770×1,200 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Weight kg 275
(300) 320
(350) 330
(360) 540
(590) 760
(830) 1,020
(1,140) 1,420(1,590) 2,300 2,360
Weight kg 275
(300) 320
(350) 330
(360) 540
(590) 760
(830) 1,020
(1,140) 1,420(1,590) 2,300 2,360
Noise level (at 1.5m in front) dB[A] 53 55 56 57 60 66 69 72 75
Noise level (at 1.5m in front) dB[A] 53 55 56 57 60 66 69 72 75

Water-cooled M-type/ S-type [Without dryer and Dryer built-in model] ( )Dryer equipped.
Water-cooled M-type/ S-type [Without dryer and Dryer built-in model] ( )Dryer equipped.
Model OSP-55S5W(R)Ⅰ OSP-75S5WL(R)Ⅰ OSP-100S5WLⅠ OSP-110S5WLⅠ
Model S-type
S-type

― ―
― OSP-55S5W(R)Ⅰ OSP-75S5WL(R)Ⅰ OSP-100S5WLⅠ OSP-110S5WLⅠ
OSP-55S6W(R)Ⅰ OSP-75S6WL(R)Ⅰ OSP-100S6WLⅠ OSP-110S6WLⅠ
OSP-55S6W(R)Ⅰ OSP-75S6WL(R)Ⅰ OSP-100S6WLⅠ OSP-110S6WLⅠ
OSP-22M5W(R)Ⅰ OSP-37M5W(R)Ⅰ OSP-55M5W(R)Ⅰ OSP-75M5WL(R)Ⅰ OSP-100M5WLⅠ OSP-110M5WLⅠ
M-type OSP-22M5W(R)Ⅰ OSP-37M5W(R)Ⅰ OSP-55M5W(R)Ⅰ OSP-75M5WL(R)Ⅰ OSP-100M5WLⅠ OSP-110M5WLⅠ
Item M-type OSP-22M6W(R)Ⅰ OSP-37M6W(R)Ⅰ OSP-55M6W(R)Ⅰ OSP-75M6WL(R)Ⅰ OSP-100M6WLⅠ OSP-110M6WLⅠ
Item OSP-22M6W(R)Ⅰ OSP-37M6W(R)Ⅰ OSP-55M6W(R)Ⅰ OSP-75M6WL(R)Ⅰ OSP-100M6WLⅠ OSP-110M6WLⅠ
Motor output kW 22 37 55 75 100 110
Motor output kW 22 37 55 75 100 110
3
Capacity m3/min 3.8 [3.3] [
6.3 5.5 ] 9.5 8.5[ ] 12.6 10.8[ ] 18.1 16.7[ ] 20 [18]
Capacity m /min 3.8 [3.3] 6.3 [5.5] 9.5 [8.5] 12.6 [10.8] 18.1 [16.7] 20 [18]
Intake air press./temp. ― Ambient pressure / 0∼40˚C (5∼40˚C)
Intake air press./temp. ― Ambient pressure / 0∼40˚C (5∼40˚C)
Discharge pressure MPa [
0.69 0.83 ] 0.75 [0.85]
Discharge pressure MPa [
0.69 0.83 ] 0.75 [0.85]
Discharge temperature ˚C Cooling water temperature 13 or lower

Discharge temperature ˚C Cooling water temperature 13 or lower

Driving method ― 4-pole TEFC motor V-belt drive 2-pole TEFC motor gear drive
Driving method ― 4-pole TEFC motor V-belt drive 2-pole TEFC motor gear drive
Starting method ― Star-delta [3 contactors]
Starting method ― Star-delta [3 contactors]
Lubricating oil capacity L NEW HISCREW OIL 2000 8 NEW HISCREW OIL 2000 13 NEW HISCREW OIL 2000 24 [not filled] NEW HISCREW OIL 2000 33 [not filled] NEW HISCREW OIL 2000 48 [not filled] NEW HISCREW OIL 2000 53 [not filled]
Lubricating oil capacity L NEW HISCREW OIL 2000 8 NEW HISCREW OIL 2000 13 NEW HISCREW OIL 2000 24 [not filled] NEW HISCREW OIL 2000 33 [not filled] NEW HISCREW OIL 2000 48 [not filled] NEW HISCREW OIL 2000 53 [not filled]
Cooling Temperature ˚C 32 or lower
Cooling Temperature ˚C 32 or lower
water Quantity
water L/min 45 65 100 100 125 170
Quantity L/min 45 65 100 100 125 170
Dew point of outlet air ˚C 10 Under pressure ―
Dew point of outlet air ˚C 10 Under pressure ―
Dryer

Rated motor output kW 1.1 2.2 3.0 ―


Dryer

Rated motor output kW 1.1 2.2 3.0 ―


Refrigerant/control system ― HFC-R407C/Capillary tube ―
Refrigerant/control system ― HFC-R407C/Capillary tube ―
Dischage pipe diameter B 1 1 1/2 2 [Flange] 2 1/2 [Flange]
Dischage pipe diameter B 1 1 1/2 2 [Flange] 2 1/2 [Flange]
Dimensions (W×D×H) mm 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Dimensions (W×D×H) mm 1,200×890×1,260 1,400×970×1,400 1,850×1,100×1,450 1,850×1,150×1,470 2,050×1,365×1,875
Weight kg 540(590) 880(950) 1,050(1,170) 1,460(1,630) 2,200 2,260
Weight kg 540(590) 880(950) 1,050(1,170) 1,460(1,630) 2,200 2,260
Noise level (at 1.5m in front) dB[A] 57 60 65 66 69 72
Noise level (at 1.5m in front) dB[A] 57 60 65 66 69 72

Air-cooled Intermediate Series 22/37kW


Air-cooled Intermediate Series 22/37kW
Model OSP-22M5AK OSP-37M5AK
Model OSP-22M5AK OSP-37M5AK
Item OSP-22M6AK OSP-37M6AK
Item OSP-22M6AK OSP-37M6AK
Motor output kW 22 37
Motor output kW 22 37
Capacity 3
m3/min 2.2 3.7
Capacity m /min 2.2 3.7
Discharge pressure MPa 1.57
Discharge pressure MPa 1.57
Dischage pipe diameter B 1 1 1/2
Dischage pipe diameter B 1 1 1/2
Dimensions (W×D×H) mm 1,250×910×1,480 1,400×910×1,480
Dimensions (W×D×H) mm 1,250×910×1,480 1,400×910×1,480
Notes :
Notes :
1. Capacity is the converted value at its inlet condition. 5. A unit is shipped without oil (55kW and above). 8.Capacity is measured at following pressure (100/110kW).
1. Noise
Capacity is is
thethe
converted
value at value
1.5m at
in its inlet condition. 5.
2. level front and 1m height in an anechoic room. 6. A
A unit is shipped
properly without is
sized receiver oilnecessary
(55kW andforabove).
energy saving. 8.Capacity
0.75MPa ismodel:
measured at following
0.70MPa, pressure
0.85MPa model:(100/110kW).
0.80MPa.
2. Noise levelmeasured
is the value
at at 1.5m intemperature
front and 1m height
and in an anechoic
dischargeroom. 6. Specifications
A properly sized receiver is necessary
3. Dew point ambient 30˚C rated pressure. 7. may be changed withoutfor energy saving.
notice. 0.75MPa model: 0.70MPa, 0.85MPa model: 0.80MPa.
3. A
4. Dew
unitpoint measured
is shipped at ambient
without temperature
a selected 30˚C breaker.
earth leakage and rated discharge pressure. 7. Specifications may be changed without notice.
4. A unit is shipped without a selected earth leakage breaker.

Mtype 10
Mtype // Stype
Stype 10
150kW
kW Dual

Energy
Energy saving
saving by
by dual
dual control
control Easy
Easy maintenance
maintenance
Energy The
The construction
construction allows
allows easy
easy daily
daily inspection.Replacement
Dual Energy saving
saving is
is achieved
achieved by inspection.Replacement
Dual control
control Vtype
Vtype Built-in
Built-in V-M Combi system.
V-M Combi system.
by
of
of suction filter, oil filter and oil separator
suction filter, oil filter and oil separator element
element and
and refilling
refilling
100
of lubricant
of lubricant can
can be
be performed
performed by by removing
removing the
the front
front panel.
panel.
100

1 Cleaning
1 Cleaning of
of Cooler
90
90
Typical
Cooler
Typical model Easy
80
80
model
Easy to
to clean
clean by
by
(%)
Cnsumption(%)

70 removing
removing the
the side
side cover.
cover.
70
PowerCnsumption

60
60
50
Variable
Variable speed
speed module
module 2
2 Refilling
Refilling Grease
Grease
50
40
Power

40
30 1
1 3 Totally
3 Totally Enclosed
Enclosed Fan-
Fan-
30
2
2
4
4 cooled
cooled Motor
Motor
20
20 Totally
Totally enclosed
enclosed motor
motor is
is
10
10 built in, high for both
Variable speed
Variable speed module
module Constant
Constant speed
speed module
module 3 5 built in, high for both
3 5 reliability
reliability and
and efficiency.
0
0 0 10 20 30 40 50 60 70 80 90 100 efficiency.
0 10 20 30 40 50 60 70 80 90 100

4 Spin-on
Spin-on type
type oil
Variable
Variable speed 4 oil
Stop

speed Variable
Unload Variable speed
speed control
control Unload Variable
Variable speed
speed control
Stop

Master module Unload Unload control


Master module separator
separator element
element
Constant
Constant speed
speed
Slave module
Slave module
Stop
Stop Load
Load 6 years Overhaul Interval 5
5 Direct
Direct gear
gear driven
Coupling
driven
Coupling adjustment
adjustment
Using Hitachi special design bearing.
Using Hitachi special design bearing.
0
0 50
50 100
100 is
is unnecessary.
unnecessary.
Air
Air Cnsumption
Cnsumption (%)
(%)

Large-size
Large-size LCD
LCD monitor
monitor Examples
Examples of
of monitoring
monitoring display
display
Display M1
M1 Monitoring
Monitoring Display M2
M2 Monitoring
Monitoring Display M3
M3 Monitoring
Monitoring Display
Display together
together with
with pressure,
pressure, current,
current, load
load factor,
factor, M1
Display
10:10* M2
Display
10:10* M3
Display
10:10*
and operation hours.
and operation hours.
M1
TYPE : INTE-
10:10* M2
TYPE : INTE-
10:10* M3
TYPE : INTE-
10:10*
Enlarged
Enlarged view
view of
of monitor
monitor TYPE : INTE- TYPE : INTE- TYPE : INTE-
SNGL-MANU-S SNGL-MANU-S SNGL-MANU-S
SNGL-MANU-S SNGL-MANU-S SNGL-MANU-S
DIS. PRESS : 0.69MPa DIS. PRESS : 0.69MPa DIS. PRESS : 0.69MPa
DIS. PRESS : 0.69MPa DIS. PRESS : 0.69MPa DIS. PRESS : 0.69MPa
RUN HR : 580h DIS. TEMP. 1 : 90˚C DATE : 2004/06/22
RUN HR : 580h DIS. TEMP. 1 : 90˚C DATE : 2004/06/22
LOAD HR : 410h DIS. TEMP. 2 : 50˚C HR.TO MAINT : 3420h
LOAD HR : 410h DIS. TEMP. 2 : 50˚C HR.TO MAINT : 3420h
LOAD NOS : 61 CURRENT : 200A NEXT MAINT : 0.5Year
LOAD NOS : 61 CURRENT : 200A NEXT MAINT : 0.5Year
LOAD RATE : 50%
LOAD RATE : 50%
LOAD TIME : 40s
LOAD TIME : 40s
UNLOAD TIME : 40s
UNLOAD TIME : 40s

*As for
*As for display
display language,
language, besides
besides English,
English, Chinese
Chinese and
and Japanese
Japanese are
are available.
available. (optional)
(optional)

Low
Low starting
starting current
current Single
Single module
module operating
operating fanction
fanction
With
With dual
dual control,
control, two
two modules
modules start
start up
up sequentially. Even
sequentially. Even in
in the
the case
case of
of one
one module
module failed,
failed, the
the other
other module
module
Surge current can be reduced.
Surge current can be reduced. can be operated independently.
can be operated independently.

STANDARD
STANDARD SPECIFICATIONS
SPECIFICATIONS
Air-cooled
Air-cooled V-type/
V-type/ M-type
M-type [Without
[Without dryer
dryer model]
model]
Air
Air cooled
cooled V
V type
type Water
Water cooled
cooled V
V type
type Air
Air cooled
cooled M
M type
type Water
Water cooled
cooled M
M type
type
Model
Model
Item OSP-150V5AD/V6AD
OSP-150V5AD/V6AD OSP-150V5WD/V6WD
OSP-150V5WD/V6WD OSP-150M5AD/M6AD
OSP-150M5AD/M6AD OSP-150M5WD/M6WD
OSP-150M5WD/M6WD
Item
Motor kW 150
150 (75×2) 150
150 (75×2)
Motor Output
Output kW (75×2) (75×2)
Intake Ambient pressure
pressure // 0∼40˚C Ambient pressure
pressure // 0∼40˚C
Intake air
air press./temp.
press./temp. ―
― Ambient 0∼40˚C Ambient 0∼40˚C
Discharge MPa 0.75〔0.85〕 0.75〔0.85〕
Discharge Pressure
Pressure MPa 0.75〔0.85〕 0.75〔0.85〕
Capacity m33/min 26.0〔24.1〕
26.0〔24.1〕 26.0〔24.1〕
26.0〔24.1〕
Capacity m /min
Capacity Built in
in V-M
V-M Combi Built in
in Dual
Dual System
Capacity Control
Control ―
― Built Combi Built System
Oil Type
Type ― NEW
NEW HISCREW
HISCREW OILOIL 2000
2000 NEW
NEW HISCREW
HISCREW OIL OIL 2000
2000
Oil ―
Lubricating 66
66 (Not
(Not filled) 66
66 (Not
(Not filled)
Lubricating Oil
Oil Capacity
Capacity liter
liter filled) filled)
Fan Motor Output
Fan Motor Output kW
kW 2.2
2.2 (1.1×2)
(1.1×2) 0.1
0.1 (0.05×2)
(0.05×2) 2.2
2.2 (1.1×2)
(1.1×2) 0.1
0.1 (0.05×2)
(0.05×2)
Discharge
Discharge Pipe
Pipe Diameter
Diameter B
B 3B
3B JIS
JIS Flange
Flange 3B
3B JIS
JIS Flange
Flange
Dimensions
Dimensions mm
mm 2,450×1,700×1,900
2,450×1,700×1,900 2,450×1,700×1,900
2,450×1,700×1,900
Weight
Weight (W
(W×D×H)
×D×H) kg
kg 3,200
3,200 3,250
3,250 3,100
3,100 3,150
3,150
Noise Level
Noise Level dB
dB 75
75 73
73 75
75 73
73
Minimum
Minimum Air
Air Receiver
Receiver m33
m 4.0 4.0
4.0 4.0
Notes :
Notes :
1. Capacity is the converted value at its inlet condition. Capacity is measured at the following pressures. 0.75MPa model at 0.7MPa 0.85MPa model at 0.8MPa
1. Capacity is the converted value at its inlet condition. Capacity is measured at the following pressures. 0.75MPa model at 0.7MPa 0.85MPa model at 0.8MPa
2. Noise level is the value at 1.5m in front and 1m height in an anechoic room. 3. A unit is shipped without oil. 4. Install air receiver with minimum capacity.
2. Noise level is the value at 1.5m in front and 1m height in an anechoic room. 3. A unit is shipped without oil. 4. Install air receiver with minimum capacity.

11
11
125~240
125~240kW
kW

High
High perfomance
perfomance in
in a
a compact
compact package
package

■55 to
to 7%
7% more
more efficient
efficient than
than conventional
conventional models. 
models.  ■
■ Integral
Integral Unload
Unload Mode
Mode as
as a
a Standard
Standard Equipment
Equipment
          
           has been equipped with
has been equipped with the
the new
new rotor
rotor In
In addition to U-mode control (stepless suction
addition to U-mode control (stepless suction throttle),
throttle),
1
profile and has also adopted original 2-stage
profile and has also adopted original 2-stage air ends air ends I-mode control (intake throttle and purge)* 1 is provided as a
I-mode control (intake throttle and purge)* is provided as a2
(compressor
(compressor mainmain units),
units), resulting
resulting inin 5
5 to
to 7%
7% increase
increase ofof standard
standard feature.
feature. This
This provides
provides excellent
excellent energy
energy efficiency*
efficiency*2
capacity
capacity compared with conventional models with
compared with conventional models with the
the same
same during capacity control as well as during normal operation.
during capacity control as well as during normal operation.
output.
output. This
This performance
performance remains
remains thethe top
top level
level compared
compared 100
100 Conventional U-type Compressor *1: A function is provided for locking the
with either oil-cooled or oil-free type models.
with either oil-cooled or oil-free type models. Conventional
(OS StandardU-type Compressor
U-type)
*1: Acompressor
function is inprovided for lockingwhen
U-type operation the
compressor in U-type
is usedoperation
as a basewhen

comparison(%)
(OS Standard U-type) the compressor load

consumptioncomparison(%)
80 13% the
unit or for applications prohibits load
compressor is used as a base
Comparison 13%
Comparison of
of capacity
capacity (240kW
(240kW model)
80 unit or for applications prohibits
model) (m33/min) pressure fluctuations.
(m /min) 21% pressure fluctuations.

42.2
42.2 45.0
45.0 60
60
21% *2: An air tank of sufficient capacity is
*2: An air tank
required to of
requiredrefer
sufficient
obtain
to obtain
capacity
the power is
saving.
the4.power saving.
Please to page
Please refer to page 4.

Powerconsumption
40

Air Air
40

20
Power 20

Example 240 kW
Conventional
Conventional model
model (OS)
(OS) 0 10 20 30
Example 240 kW
40 50
0 10 20 30 40 50
Usage air volume (m33/min)
Usage air volume (m /min)

Example
Example of
of 2-stage
2-stage HISCREW’s
HISCREW’s Maintenance
Maintenance saving
saving
advantage
advantage in power saving
in power saving ■
■ Daily
Daily routine
routine work
work of
of drain
drain evacuation
evacuation isis unnecessary.
unnecessary.
Includes
Includes an automatic temperature control valve
an automatic temperature control valve as
as standard
standard equipment,
equipment,
which
which automatically controls the temperature in the oil separator
automatically controls the temperature in the oil separator in
in order
order
not to produce drain. Bothersome daily routine work of drain evacuation
not to produce drain. Bothersome daily routine work of drain evacuation
from
from the
the oil
oil separator
separator is
is not
not necessary.
necessary.

Example of 240kW
Example of 240kW ■
■ Greatly
Greatly Reduced
Reduced Lubricant
Lubricant Consumption
Consumption
Discharge pressure 0.69MPa
Discharge pressure 0.69MPa Oil consumption (cm33/m33)
The Oil consumption
The newly developed oil
newly developed oil separator
separator reduces
Conventional model : OS-240U6 (cm /m )
Compressor
Compressor
Conventional model : OS-240U6
New model : OSP-240S6WT reduces
New model : OSP-240S6WT the
the amount
amount of of oil
oil contained
contained in in the
the 0.03
Operating time
Operating time
6,000 hours
6,000 hours 0.03
discharged
discharged airair to
to 0.003
0.003 cm
cm3/m
3
/m3 (1/10
3
(1/10 th
th
that
that of conventional compressors), which
of conventional compressors), which 1
Air
Air consumption
consumption :: 30m
30m3/min
3
/min 110
gives
gives a
a new
new image
image toto large
large oil-cooled
oil-cooled
Power-saving
Power-saving ratio
ratio == 13%
13%
10
203MWh
screw
screw compressors.
compressors. This
This makes
makes itit possible
possible 0.003
to
0.003
Power
Power savings
savings =
= MWh to provide
provide clean
clean compressed
compressed air air and
and
reduces Conventional model
reduces the
the time
time spent
spent adding
adding lubricant.
lubricant. Conventional model

STANDARD
STANDARD SPECIFICATIONS
SPECIFICATIONS
Model OSP-125S5WT OSP-150S6WT OSP-160S5WT OSP-190S6WT OSP-200S5WT OSP-240S6WT
Item Model OSP-125S5WT OSP-150S6WT OSP-160S5WT OSP-190S6WT OSP-200S5WT OSP-240S6WT
Item
Discharge pressure MPa 0.69(0.83)
Discharge pressure MPa 0.69(0.83)
Motor output kW 125 150 160 190 200 240
Motor output kW 125 150 160 190 200 240
Capacity 3
m3/min 23.3(20.5) 28.5(25.0) 30.0(26.5) 36.5(32.1) 37.7(33.2) 45.0(39.6)
Capacity m /min 23.3(20.5) 28.5(25.0) 30.0(26.5) 36.5(32.1) 37.7(33.2) 45.0(39.6)
Intake air press./temp. ― Ambient pressure / 0∼40˚C
Intake air press./temp. ― Ambient pressure / 0∼40˚C
Discharge temperature ˚C Cooling water temperature + 13 or lower
Discharge temperature ˚C Cooling water temperature + 13 or lower
Lubricating oil capacity L Mineral oil 100 [not filled] Mineral oil 120 [not filled] Mineral oil 150 [not filled]
Lubricating oil capacity L Mineral oil 100 [not filled] Mineral oil 120 [not filled] Mineral oil 150 [not filled]
Temperature ˚C 32 or lower
Cooling water Temperature ˚C 32 or lower
Cooling water Quantity L/min 170 205 215 255 270 325
Quantity L/min 170 205 215 255 270 325
Dischage pipe diameter ― 3B JIS10k Flange 4B JIS10k Flange
Dischage pipe diameter ― 3B JIS10k Flange 4B JIS10k Flange
Dimensions (W×D×H) mm 2,303×1,400×1,555 2,503×1,650×1,555
Dimensions (W×D×H) mm 2,303×1,400×1,555 2,503×1,650×1,555
Weight kg 3,550 3,550 3,600 4,700 4,800 4,850
Weight kg 3,550 3,550 3,600 4,700 4,800 4,850
Noise level (at 1.5m in front) dB[A] 73 74 75 75 75 75
Noise level (at 1.5m in front) dB[A] 73 74 75 75 75 75
Notes :
Notes
1. :
Capacity is the converted value at its inlet condition. 2. Noise level is the value at 1.5m in front and 1m height in an anechoic room. 3. Dew point measured at ambient temperature 30˚C and rated discharge pressure.
1. A
4. Capacity is the converted
unit is shipped without avalue at itsearth
selected inlet leakage
condition. 2. Noise
breaker. level
5. A unitisisthe value at
shipped 1.5m in
without oil.front
6. Aand
unit1m height inwithout
is shipped an anechoic room. 7.3.The
the starter. Dewdimension
point measured at ambient
of starter temperature
is 600mm 30˚C andinrated
in width, 1000mm discharge
depth, 1400mm pressure.
in height.
4. A unit is shipped without is
8. A properly sized receiver a selected
necessary earth leakagesaving.
for energy breaker.9.5.Specifications
A unit is shipped
may without oil. 6.
be changed A unitnotice.
without is shipped without the starter. 7. The dimension of starter is 600mm in width, 1000mm in depth, 1400mm in height.
8. A properly sized receiver is necessary for energy saving. 9. Specifications may be changed without notice.

150kW 12
150kW Dual
Dual Vtype/Mtype
Vtype/Mtype // 2-stage
2-stage HISCREW
HISCREW 12
Auxiliary equipment to enhance air quality
We
We recommend
recommend using
using the
the following
following auxiliary
auxiliary equipment
equipment with
with your
your compressors
compressors for
for effective
effective and
and systematic
systematic
use
use of
of your
your facilities.
facilities.

Examples
Examples of
of air
air compressed
compressed air
air system
system

Nominal
Nominal filtration
filtration rating/1
rating/1 m
m

Air
Air receiver
receiver Line
Line filter
filter

Oil
Oil content/0.01wtppm
content/0.01wtppm

Line
Line filter
filter Micro
Micro mist
mist filter
filter
Air
Air dryer
dryer

Oil
Oil content/0.003wtppm
content/0.003wtppm

Line Micro
Micro mist
mist Deodorant
Line filter
filter Deodorant
filter
filter filter
filter

Cold
Cold air
air

Line Micro
Micro mist
mist Deodorant
Deodorant
Line filter
filter filter filter PUROFRIO
filter filter PUROFRIO
Remote
Remote monitoring system Multi
monitoring system Multi unit
unit controller
controller
COSMOS
COSMOS
compatible
compatible with
with HG
HG Version
Version of
of 2000
2000 series.
series.

13
13
R407C
R407C

HITACHI
HITACHI AIR
AIR DRYER
DRYER HDR series of HDR series of
HDR series of HDR series of
Supply air with less moisture. medium size large size
Supply air with less moisture. medium size large size

Hitachi air dryers are compact in construction and designed to be suitable for combination with HISCREWs.
Hitachi air dryers are compact in construction and designed to be suitable for combination with HISCREWs.
HDR series, which is of high performance and carries inlet air of high temperature, is available in a variety of models.
HDR series, which is of high performance and carries inlet air of high temperature, is available in a variety of models.

HDR medium-sized series


HDR medium-sized series
Model
Model HDR-7.5AE HDR-15AE HDR-22AE HDR-37AE HDR-55AE HDR-75AE HDR-100AE
Item HDR-7.5AE HDR-15AE HDR-22AE HDR-37AE HDR-55AE HDR-75AE HDR-100AE
Item
Applicable compressor kW 7.5 15 22 37 55 75 100
Applicable compressor kW 7.5 15 22 37 55 75 100
3
Capacity (Note 1) m3/min 1.1/1.34 2.4/2.8 3.9/4.2 6.5/7.0 9.2/9.5 12.8/13.4 16.8/17.6
Capacity (Note 1) m /min 1.1/1.34 2.4/2.8 3.9/4.2 6.5/7.0 9.2/9.5 12.8/13.4 16.8/17.6
Max. inlet pressure of compressed air MPa 0.93 0.97
Max. inlet pressure of compressed air MPa 0.93 0.97
Max. inlet temperature of compressed air ˚C 65 80 60
Max. inlet temperature of compressed air ˚C 65 80 60
Ambient temperature ˚C 5∼40
Ambient temperature ˚C 5∼40
Dew point of outlet air ˚C 10 under pressure
Dew point of outlet air ˚C 10 under pressure
Rated output of refrigerator kW 0.25 0.5 1.1 1.1 1.85 3.0 3.75
Rated output of refrigerator kW 0.25 0.5 1.1 1.1 1.85 3.0 3.75
Cooling method of condenser ー Air cooling
Cooling method of condenser ー Air cooling
Refrigerant control device ー Capillary tube
Refrigerant control device ー Capillary tube
Capacity control device ー Hot gas bypass valve
Capacity control device ー Hot gas bypass valve
Refrigerant used ー HFC-R407C
Refrigerant used ー HFC-R407C
Finish color ー Ivory (Munsell No. 5Y8.5/1)
Finish color ー Ivory (Munsell No. 5Y8.5/1)
Pipe conection B 3/4 1 1 1 1/2 1 1/2 2 Flange 2 Flange
Pipe conection B 3/4 1 1 1 1/2 1 1/2 2 Flange 2 Flange
Dimensions (W×D×H) mm 255×656×680 303×678×681 303×753×681 303×1,033×751 303×1,083×981 431×1,183×1,124 491×1,323×1,164
Dimensions (W×D×H) mm 255×656×680 303×678×681 303×753×681 303×1,033×751 303×1,083×981 431×1,183×1,124 491×1,323×1,164
Weight kg 33 54 58 94 127 205 245
Weight kg 33 54 58 94 127 205 245
Accessories ー Auto drain trap / Drain valve
Accessories ー Auto drain trap / Drain valve
Notes:
Notes:
1. The capacity refer to the following operating condition : 32℃ ambient temperature, 40℃ inlet temperature, 0.69MPa inlet pressure, 10℃ dew point of under pressure.
1.
2. The
Initialcapacity refer
pressure to the
losses of following
the dryersoperating condition
are less than : 32℃
or equal ambient temperature, 40℃ inlet temperature, 0.69MPa inlet pressure, 10℃ dew point of under pressure.
to 0.03MPa
2. Contact
3. Initial pressure losses
our service of the
outlet dryers
if you are like
would lesstothan
useor
in equal to 0.03MPa
corrosive gas environment.
3. Contact our service outlet if you would like to use in corrosive
4. The dimensions show surface of panels (not include piping, bolt) gas environment.
4. The dimensions show surface of panels (not include piping, bolt)

HDR large-sized series


HDR large-sized series
Model
Model HDR-120WE HDR-150WE HDR-190WE HDR-240WE HDR-300WE HDR-380WE HDR-120AE HDR-150AE HDR-190AE HDR-240AE HDR-300AE HDR-380AE
Item HDR-120WE HDR-150WE HDR-190WE HDR-240WE HDR-300WE HDR-380WE HDR-120AE HDR-150AE HDR-190AE HDR-240AE HDR-300AE HDR-380AE
Item
Applicable compressor kW ー 150 190 240 ー ー ー 150 190 240 ー ー
Applicable compressor kW ー 150 190 240 ー ー ー 150 190 240 ー ー
3
Capacity (Note 1) m3/min 21/25 27/31 35/41 42/49 51/60 64/75 20/23 25/30 32/38 38/45 47/55 59/69
Capacity (Note 1) m /min 21/25 27/31 35/41 42/49 51/60 64/75 20/23 25/30 32/38 38/45 47/55 59/69
Max. inlet pressure of compressed air MPa 0.97 0.93 0.97 0.93
Max. inlet pressure of compressed air MPa 0.97 0.93 0.97 0.93
Max. inlet temperature of compressed air ℃ 60
Max. inlet temperature of compressed air ℃ 60
Ambient temperature ℃ 2∼40
Ambient temperature ℃ 2∼40
Dew point of outlet air ℃ 10 under pressure
Dew point of outlet air ℃ 10 under pressure
Rated output of refrigerator kW 2.2 3.0 3.75 3.75 2.2×2 3.0×2 2.2 3.0 3.75 3.75 2.2×2 3.0×2
Rated output of refrigerator kW 2.2 3.0 3.75 3.75 2.2×2 3.0×2 2.2 3.0 3.75 3.75 2.2×2 3.0×2
Cooling method of condenser ー Water cooling Air cooling
Cooling method of condenser ー Water cooling Air cooling
Refrigerant control device ー Capillary tube
Refrigerant control device ー Capillary tube
Capacity control device ー Hot gas bypass valve Hot gas bypass valve Hot gas bypass valve Hot gas bypass valve
Capacity control device ー Hot gas bypass valve Hot gas bypass valve Hot gas bypass valve Hot gas bypass valve
Refrigerant used ー HFC-R407C
Refrigerant used ー HFC-R407C
Finish color ー Ivory (Munsell No. 5Y8.5/1)
Finish color ー Ivory (Munsell No. 5Y8.5/1)
Pipe conection B 2 11 2 Flange 3 Flange 4 Flange 5 Flange 2 11 2 Flange 3 Flange 4 Flange 5 Flange
Pipe conection B 2 2 Flange 3 Flange 4 Flange 5 Flange 2 2 Flange 3 Flange 4 Flange 5 Flange

Dimensions (W×D×H) 672×1,260 905×1,969 2,020×1,100 672×1,260 950×1,290 905×1,969 2,020×1,100


mm 672×1,260 950×1,290×1,332 905×1,969 2,020×1,100 672×1,260 950×1,290 905×1,969 2,020×1,100
Dimensions (W×D×H) mm ×1,276 950×1,290×1,332 ×1,583 ×1,650 ×1,276 ×1,332 ×1,583 ×1,650
×1,276 ×1,583 ×1,650 ×1,276 ×1,332 ×1,583 ×1,650
Weight kg 250 348 352 540 720 840 255 358 362 540 740 860
Weight kg 250 348 352 540 720 840 255 358 362 540 740 860
Accessories ー Auto drain trap / Drain valve
Accessories ー Auto drain trap / Drain valve
Notes:
Notes:
1. The capacity refer to the following operating condition : 32℃ ambient temperature, 40℃ inlet temperature, 0.69MPa inlet pressure, 10℃ dew point of under pressure.
1.
2. The
Initialcapacity refer
pressure to the
losses of following
the dryersoperating condition
are less than : 32℃
or equal ambient temperature, 40℃ inlet temperature, 0.69MPa inlet pressure, 10℃ dew point of under pressure.
to 0.03MPa
2. Contact
3. Initial pressure losses
our service of the
outlet dryers
if you are like
would lesstothan
useorin equal to 0.03MPa
corrosive gas environment.
3. The
4. Contact our service
dimensions showoutlet if you
surface ofwould
panelslike
(nottoinclude
use in corrosive gas environment.
piping, bolt)
4. The dimensions show surface of panels (not include piping, bolt)

Optional parts 14
Optional parts 14
HITACHI
HITACHI FILTER
FILTER
Provides
Provides clean
clean air
air by
by removing
removing dirt
dirt particles
particles in
in compressed
compressed air.
air.

Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Capacity (converted to the ambient pressure) m3/min
3
1.2 1.8 2.4 3.9 6.6 10.6 13.8 20 24.4 40 48.8
Capacity (converted to the ambient pressure) m /min 1.2 1.8 2.4 3.9 6.6 10.6 13.8 20 24.4 40 48.8
Air
Air Inlet air temperature ℃ 30
condition Inlet air temperature ℃ 30
item

condition
Commonitem

Inlet air pressure MPa 0.69


Inlet air pressure MPa 0.69
Common

Use Usable fluid ー Compressed air


Use Usable fluid ー Compressed air
conditions Max. pressure
conditions Max. pressure MPa 0.97
MPa 0.97
Connecting pipe diameter B(A) Rc1/2 Rc3/4 Rc3/4 Rc1 Rc11/2 Rc11/2 Rc2 Rc2 21/2Flange 3Flange 4Flange
Connecting pipe diameter B(A) Rc1/2 Rc3/4 Rc3/4 Rc1 Rc11/2 Rc11/2 Rc2 Rc2 21/2Flange 3Flange 4Flange

Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item Model HAF-7.5B HAF-11B HAF-15B HAF-22B HAF-37B HAF-55B HAF-75B HAF-100B HAF-240A HAF-400A HAF-480A
Item Model HAF-7.5B HAF-11B HAF-15B HAF-22B HAF-37B HAF-55B HAF-75B HAF-100B HAF-240A HAF-400A HAF-480A
Line
Line filter
filter
Use
Use
Inlet air temperature range
Inlet air temperature range


5∼60
5∼60
conditions Ambient temperature range
This filter eliminates conditions Ambient temperature range
℃ 2∼60
This filter eliminates ℃ 2∼60
solid materials ranging Filtration rating μm 1(Note 1) approx. 3
solid materials ranging Filtration rating μm 1(Note 1) approx. 3
filter

in size from 1 to 3
Linefilter

in size from 1 to 3 Filtration efficiency % 99.999


micron and larger. Filtration efficiency % 99.999
micron and larger.
Line

Pressure Initial MPa 0.005 or lower


Pressure Initial MPa 0.005 or lower
drop Terminal(to replace element) MPa 0.07
drop Terminal(to replace element) MPa 0.07
Dimensions (diameter×length) mm 90×231 115×287 115×455 160×509 170×591 170×699 173×792 173×949 420×1,690 500×1,521 500×1,752
Dimensions (diameter×length) mm 90×231 115×287 115×455 160×509 170×591 170×699 173×792 173×949 420×1,690 500×1,521 500×1,752
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135

Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item Model HMF-7.5B HMF-11B HMF-15B HMF-22B HMF-37B HMF-55B HMF-75B HMF-100B HMF-240A HMF-400A HMF-480A
Model HMF-7.5B HMF-11B
Micro
Micro mist
mist filter
filter
Item
Use Inlet air temperature range ℃
HMF-15B HMF-22B HMF-37B HMF-55B HMF-75B HMF-100B HMF-240A HMF-400A HMF-480A
5∼60
This filter eliminates oil Use Inlet air temperature range ℃ 5∼60
This filter eliminates oil conditions
Ambient temperature range
conditions ℃ 2∼60
and solid materials
filter

Ambient temperature range ℃ 2∼60


and solid materials
mistfilter

whose sizes are 0.01 Outlet oil content wtppm 0.01(Note 2) approx. 0.5
whose sizes are 0.01 Outlet oil content wtppm 0.01(Note 2) approx. 0.5
Micromist

micron and larger.


micron and larger. Pressure Initial MPa
MPa
0.01
The outlet oil content Pressure Initial 0.01
Micro

The outlet oil content loss Terminal(to replace element) MPa 0.07
will be 0.01wtppm. loss Terminal(to replace element) MPa 0.07
will be 0.01wtppm.
Dimensions(diameter×length) mm 90×231 115×368 115×536 160×582 170×664 170×772 173×865 173×1,022 420×1,690 500×1,521 500×1,752
Dimensions(diameter×length) mm 90×231 115×368 115×536 160×582 170×664 170×772 173×865 173×1,022 420×1,690 500×1,521 500×1,752
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135

Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Item 7.5B 11B 15B 22B 37B 55B 75B 100B 240A 400A 480A
Model HKF-7.5B HKF-11B HKF-15B HKF-22B HKF-37B HKF-55B HKF-75B HKF-100B HKF-240A HKF-400A HKF-480A
Deodorant
Deodorant filter
filter
Item
Item Model HKF-7.5B HKF-11B HKF-15B HKF-22B HKF-37B HKF-55B HKF-75B HKF-100B HKF-240A HKF-400A HKF-480A
This filter absorbs and Use Inlet air temperature range ℃ 5∼60
This filter absorbs and Use Inlet air temperature range ℃ 5∼60
eliminates oil vapors conditions
filter

Ambient temperature range ℃ 2∼60


eliminates oil vapors conditions
Deodorantfilter

Ambient temperature range ℃ 2∼60


that have unpleasant
that have unpleasant Outlet oil content wtppm 0.003(Note 3) approx. 0.1
Deodorant

odor. The outlet oil Outlet oil content wtppm 0.003(Note 3) approx. 0.1
odor. The outlet oil Pressure loss MPa 0.007 0.005{0.05}
content will be Pressure loss MPa 0.007 0.005{0.05}
content will be
0.003wtppm. Dimensions (diameter×length) mm 90×211 115×231 115×231 160×308 170×390 170×498 173×591 173×748 420×1,690 500×1,521 500×1,752
0.003wtppm. Dimensions (diameter×length) mm 90×211 115×231 115×231 160×308 170×390 170×498 173×591 173×748 420×1,690 500×1,521 500×1,752
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 80 120 135
※ Install an air dryer in the pre-stage of these filters.
※ Install
Notes : an air dryer in the pre-stage of these filters.
Notes
1. :
corresponds to the 2nd grade of "compressed air grades" in ISO8573-1. The inlet oil content is 3wtppm.
1.
2. corresponds to
corresponds to the
the 2nd gradeof
1st grade of"compressed
"compressedairairgrades"
grades"ininISO8573-1.
ISO8573-1.The
Theinlet
inletoil
oilcontent
contentisis3wtppm.
3wtppm.
2. converted
3. corresponds to the
value 1st grade
by "the of "compressed
test method air grades"
of oil content" in ISO8573-1.
in ISO8573-2. Theoilinlet
The inlet oil content
content is 3wtppm.
is 0.01wtppm.
3. converted value by "the test method of oil content" in ISO8573-2. The inlet oil content is 0.01wtppm.

15
15
UNIT
UNIT CONTROLLER
CONTROLLER Note:
Note: The
The specification
specification of
of the
the control
control board
board could
could differ
differ according
according to
to the
the air
air compressor
compressor model
model to
to be
be connected.
connected.

Multi
Multi Unit
Unit Controller
Controller (MULTI
(MULTI ROLLER
ROLLER EX)
EX) ■Standard
■Standard specs
specs
Model
This
This equipment
equipment enables
enables to
to operate
operate plural
plural Item
Model MR26-4E
MR26-4E MR26-8E
MR26-8E MR26-12E
MR26-12E
Item
efficiently. It
efficiently. It excludes
excludes unload
unload operations
operations of
of no
no use
use Power
Power Supply
Supply Single-phase
Single-phase AC100V/200V
AC100V/200V(Common)
(Common)
and levels
and levels operation
operation hours
hours of
of each
each unit.
unit. Frequency
Frequency 50/60Hz
50/60Hz((Common)
Common)
Controlled
Controlled Units
Units 4 8 12
4 8 12
Discharge
Discharge Pressure 0
Pressure 0 to
to 1
1 MPa(Digital
MPa( Digital Display)
Display)

Input
Control Operation Answer,
Answer, Shutdown
Shutdown

Input
Control Operation
External Start,
External Start, Stop,
Stop, External
External Forced
Forced Start-up,
Start-up, Flow
Flow Volume
Volume
Control Start, Stop,
Stop, Load,
Load, PID
PID Command
Command

Output
Control Start,

Output
External Start,
External Start, Shutdown,
Shutdown, Auto
Auto
Dimensions
Dimensions (W×D×H)
(W×D×H) 400×200×600 (mm)
400×200×600 (mm) 500×200×900 (mm)
500×200×900 (mm) 500×200×1,200
500×200×1,200 (mm)
(mm)
Weight
Weight 19
19 (kg)
(kg) 32
32 (kg)
(kg) 37
37 (kg)
(kg)

Alternate
Alternate operation
operation panel
panel (Dual
(Dual roller
roller II)
II) ■Standard
■Standard specs
specs
Model
Model
This
This is
is a
a highly
highly functional
functional new
new model
model of of alternate
alternate operation
operation Item
Item
SDR-2
SDR-2
panel, which
panel, which can
can control
control 2
2 units
units of
of interchangeably.
interchangeably. Power
Power source
source AC100V [AC200V is
AC100V(−10%+10%)
[AC200V
(−10%+10%) is usable
usable by
by connector
connector switching.]
switching.]
If the
If the 2
2 units
units are
are operated
operated asas a
a main
main andand aa standby
standby units,
units, they
they Frequency
Frequency 50/60Hz
50/60Hz
will Controllable
Controllable number
number of
of units
will constitute a standby system. It is also useful for leveling off
constitute a standby system. It is also useful for leveling units 2
off Discharge pressure
pressure
2

0∼ ∼1
1M MP
Pa
the
the operation
operation hours
hours of
of the
the 22 units.
units.
Discharge a
Input

Control Remote
Remote setting,
setting, Remote
Remote operation
Input

Control operation

● Various
Various alternate
alternate and/lead-lag
and/lead-lag operation
operation are
are External
External Operation,
Operation, stop,
stop, failure,
failure, Remote
Remote operation
operation
applicable
applicable to to S-type
S-type models,
models, where
where AUTO
AUTO function Control Operation,
Operation, stop,
stop, load
load instruction
Output

function Control instruction


Output

is
is not
not necessary.
necessary. External
External Operation,
Operation, failure,
failure, automatic
automatic

● The
The large
large LCD
LCD andand the
the touch
touch panel
panel have
have improved
improved Controllable
Controllable width
width of
of discharge
discharge Min.±0.02MP
Min.±0.02M Pa (Note1)
a(Note1)
its
its user-friendliness.
user-friendliness. Dimensions (W×D×H) 300×160×400
Dimensions (W×D×H) 300×160×400 (mm)
(mm)
It
It has
has been
been downsized
downsized too.too. The
The built-in
built-in sensor
sensor has has Weight 8.5 (kg)
(kg)
Weight 8.5
digitalized
digitalized pressure
pressure setting,
setting, which
which facilitates
facilitates piping
piping Notes:
Notes:
work
work and
and adjustments.
adjustments.
1. When setting the minimum width of the pressure, contact our agent separately.
1. When setting the minimum width of the pressure, contact our agent separately.
2. Compressors except those driven by inverters are controllable by this equipment.

● It
It comes
comes equipped
equipped with
with functions
functions of
of automatic
automatic
2. Compressors except those driven by inverters are controllable by this equipment.

restart
restart just
just after
after momentary
momentary power
power failure,
failure, calendar
calendar
operation,
operation, detailed
detailed memory
memory of of failures
failures and
and long-
long-
term
term suspension.
suspension.

● Central
Central control
control toto stop
stop operation
operation isis possible.
possible. It It
comes
comes equipped
equipped withwith input/output
input/output terminals
terminals forfor
external
external control.
control.

HITACHI
HITACHI OIL
OIL CLEANER
CLEANER
Useful
Useful for
for long
long time
time and
and continuous
continuous operations.
operations.
In
In oil
oil flooded
flooded type
type screw
screw compressors,
compressors, removal
removal of
of oil
oil condensate
condensate is is crucial.
crucial. This
This oil
oil cleaner
cleaner is
is ingeniously
ingeniously designed
designed so
so that
that
the condensate is separated and purged during operation. Hitachi Oil Cleaner is ideal for applications where
the condensate is separated and purged during operation. Hitachi Oil Cleaner is ideal for applications where continuouscontinuous
operation
operation isis required,
required, and
and where
where the
the usage
usage capacity
capacity varies
varies greatly.
greatly.
Model
Model ※ ※ ※
Item OWS-1
OWS-1 ※OWS-1A
OWS-1A OWS-2
OWS-2 ※OWS-2A
OWS-2A OWSK-1
OWSK-1 ※OWSK-1A
OWSK-1A
Item
Applicable 7.5∼15kW ((22/37kW 1.57MPa))
Applicable model
model Over
Over 22kW
22kW 7.5∼15kW 22/37kW 1.57MPa
Pressure range
Pressure range of
of normal
normal operation
operation MPa 0.39∼0.97 0.39∼0.97
0.39∼0.97 0.39∼1.67
MPa 0.39∼0.97 0.39∼1.67
Shell
Shell capacity
capacity L 15 9
9 15
L 15 15
Ambient
Ambient temperature
temperature ℃ 0∼40 0∼40
0∼40 0∼40
0∼40
℃ 0∼40
Fluids
Fluids handled Oil Oil
Oil and drain
and Oil
Oil and drain
and
handled ―
― Oil and drain
and drain drain drain
Visual
Visual check Level
Level switch
check with
with switch of
of electrostatic
electrostatic Visual
Visual check
check with Level switch
with Level switch of
of electrostatic Visual check
electrostatic Visual check with Level switch
with Level switch of
of electrostatic
electrostatic
Condensate
Condensate level
level sensing
sensing method
method ― the
― the drain
drain gauge
gauge capacitance
capacitance type
type the
the drain
drain gauge
gauge capacitance
capacitance type
type the
the drain
drain gauge
gauge capacitance
capacitance type
type
Automatic
Automatic exhaustion
exhaustion Automatic
Automatic exhaustion
exhaustion Automatic
Automatic exhaustion
exhaustion
Drain
Drain exhausting
exhausting method
method ―
― Manual
Manual Manual
Manual Manual
Manual
by solenoid
by solenoid valve.
valve. by
by solenoid
solenoid valve.
valve. by
by solenoid
solenoid valve.
valve.
Condensate
Condensate exhaustion
exhaustion amount
amount 640∼800/1 100/1 activation 700∼1,300/1
cm3
cm3 ―
― 640∼800/1 ―
― 100/1 activation ―
― 700∼1,300/1
when
when solenoid activation
activation (20
( sec.) (5 sec) activation
activation (20
( sec.)
solenoid 20 sec.) (5 sec) 20 sec.)
Weight kg
kg 42 54 35 47 50 62
Weight 42 54 35 47 50 62
Dimensions mm 394×350×1,086 625×356×1,086 442×360×800 841×360×800 908×379×1,193
685×350×1.193 908×379×1,193
Dimensions (W×D×H)
(W×D×H) mm 394×350×1,086 625×356×1,086 442×360×800 841×360×800 685×350×1.193
※ For these models, electric power source of single phase, 200V is necessary.
※ For these models, electric power source of single phase, 200V is necessary.

Optional 16
Optional parts
parts 16
PUROFRIO
Equipment to produce extremely cold air.

(1) The generator of extremely cold air with a built-in heatless dryer, (2) The cooling unit with a built-in heatless dryer, which is to be installed
which is to be installed separately. as a distributed component of existing air usage system.
Model Model
Item HSC-09D HSC-18D Item HSC-09 HSC-18

Fluid ー Compressed air (Note 1) Fluid ー Compressed air, Nitrogen gas (Note 3)
Ambient temperature ℃ 5∼35 Ambient temperature ℃ 5∼35

Usable range

Usable range
Inlet fluid temperature ℃ 5∼35 Inlet fluid temperature ℃ 5∼35
Inlet fluid pressure MPa 0.49∼0.92 Inlet fluid pressure MPa 0.49∼0.92
Inlet flow volume m3/min 0.85(0.4) 1.8(0.9) Inlet flow volume m3/min 0.74(0.29) 1.5(0.63)

low volume
Processing
low volume
Processing
Discharge flow volume m3/min 0.74(0.29) 1.5(0.63) Discharge flow volume m3/min 0.74(0.29) 1.5(0.63)
(Note 2) Discharge fluid temperature ℃ -10(-20) (Note 2) Discharge fluid temperature ℃ -10(-20)
Power source V 50/60Hz)
( 3φ 200/200・220 Power source V 50/60Hz)
( 3φ 200/200・220
Rated output of refrigerator W 800 1,100 Rated output of refrigerator W 800 1,100
Cooling method of condenser ー Air cooling Cooling method of condenser ー Air cooling
Capacity control device ー Hot gas bypass valve Capacity control device ー Hot gas bypass valve
Refrigerant ー HFC-R404A Refrigerant ー HFC-R404A
Piping diameter B 1/2 3/4 Piping diameter B 1/2 3/4
Weight kg 90 160 Weight kg 70 120
Dimensions (W×D×H) mm 420×670×915 485×925×1,350 Dimensions (W×D×H) mm 300×705×790 300×955×955
Accessories ー Inlet valve, discharge valve Accessories ー Inlet valve, discharge valve
Notes:
1. The fluid must have been passed through the line, micro mist and deodorant filters and its dew point must be 10℃ and below under the pressure, which is equivalent to -17℃ and below under
the atmospheric pressure.
2. The values in the category of processing flow volume were measured at 30℃ of inlet gas temperature, 30℃ of ambient temperature, and 0.69MPa of inlet pressure.
Contact our service outlet and inquire about the discharge temperature separately, since it changes dependent on the processing flow volume and the inlet fluid temperature.
3. The fluid must have been passed through a heatless dryer, and its dew point must be -40℃ and below under the pressure.

Cooling applications for PROFRIO


■ Type selection

●Rapid cooling after adhering -8


HSC-09D HSC-18D
●Grinding -10

Outlet air temperature(℃) -12


●Lower temperature for inspecting semiconductor devices
-14
●Rapid cooling of molds for plastic
-16

●Cooling of woodworking machinery -18

●Cooling of machine tools -20

-22
●Improvement of process efficiency
-24
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2
Capacity(m3/min)

Necessary capacity of power transformer


Select an appropriate power transformer to secure model Min. capacity of transformer
OSP-7.5∼15kW 30KVA
necessary power source for a compressor.
OSP-22 50KVA
OSP-37 75KVA
OSP-55 100KVA
OSP-75 150KVA
OSP-100 300KVA
Note : The capacity of transformer changes dependent on the specs of power cable.

Safty Precautions
■ Regarding compressor application
● The compressor described in this catalog utilizes only air as a gas. Absolutely avoid using it for compression of a gas other than air
  ー this could result in a fire hazard or damage to the equipment.
● Never use compressed air for human breathing.

■ Regarding installation site


● Install this compressor indoors. Avoid using it at a place susceptible to moisture such as precipitation or vapors ー this could result in
  a fire hazard, electric shock, rusting or shortened life of parts.
● There should be no explosive or flammable gas(acetylene, propane, etc.) , organic solvent, explosive powder or flame used near the
  compressor ー otherwise there is a fire hazard.
● Avoid using the compressor at a palace where there is corrosive gas such as ammonia, acid, salt sulfurous acid gas, etc.
  ー this could result in rusting, shortened life, or damage to the equipment.

■ Regarding usage
● Before use, be sure to read the instruction manual thoroughly for correct use of the compressor.
● Absolutely avoid modifying the compressor or its componentsーthis could result in damage or malfunction.

17
Beware of ventilation in the compressor room
is
is not
not unusable
unusable in
in aa closed
closed room.
room. Install
Install the
the HISCEREW
HISCEREW inin aa proper
proper
installation
installation location
location where
where the
the heat
heat generated
generated by
by the
the can
can be
be ventilated.
ventilated.
(1) Ventilation without a Duct (Figure A) For ventilation of the air exhausted from an air dryer, install a ventilating fan with a capacity
(1) Ventilation without a Duct (Figure A) For ventilation of the air exhausted from an air dryer, install a ventilating fan with a capacity
For ventilation without an exhaust duct, install a ventilating fan with a capacity as specified as specified by Recommended Ventilating Fan 3 in the Ventilation Data.
For ventilation without an exhaust duct, install a ventilating fan with a capacity as specified as specified by Recommended Ventilating Fan 3 in the Ventilation Data.
by Recommended Ventilating Fan 1 in the Ventilation Data. The capacity is based on the (3) Ventilation with a Duct and Ventilating Fan (Figure C)
by Recommended Ventilating Fan 1 in the Ventilation Data. The capacity is based on the (3) Ventilation with a Duct and Ventilating Fan (Figure C)
allowable room temperature rise of 5˚C. Position the ventilating fan as high as possible on If the pressure loss as calculated as above (2) is 20 Pa or higher, a ventilating fan is
allowable room temperature rise of 5˚C. Position the ventilating fan as high as possible on If the pressure loss as calculated as above (2) is 20 Pa or higher, a ventilating fan is
the wall. required on the duct. Install the duct with keeping a gap of 200 to 300mm between the duct
the wall. required on the duct. Install the duct with keeping a gap of 200 to 300mm between the duct
(2) Ventilation with a Duct and without a Ventilating Fan (Figure B) end and the grilled air exhaust (air compressor part only) of the HISCREW's top enclosure
(2) Ventilation with a Duct and without a Ventilating Fan (Figure B) end and the grilled air exhaust (air compressor part only) of the HISCREW's top enclosure
For ventilation with an exhaust duct, calculate the duct's pressure loss based on the Air panel. On the other end of the duct, install a ventilating fan with a capacity as specified by
For ventilation with an exhaust duct, calculate the duct's pressure loss based on the Air panel. On the other end of the duct, install a ventilating fan with a capacity as specified by
Exhaust (air compressor) in the Ventilation Data. Recommended Ventilating Fan 2 in the Ventilation Data. When selecting a ventilating
Exhaust (air compressor) in the Ventilation Data. Recommended Ventilating Fan 2 in the Ventilation Data. When selecting a ventilating
If the calculated pressure loss is lower than 20 Pa, a ventilating fan is not required on the fan, consider not only this capacity but also the duct pressure loss and the exhausted air
If the calculated pressure loss is lower than 20 Pa, a ventilating fan is not required on the fan, consider not only this capacity but also the duct pressure loss and the exhausted air
duct. Install the duct with its detachable end making direct contact with the grilled air temperature rise.
duct. Install the duct with its detachable end making direct contact with the grilled air temperature rise.
exhaust (air compressor part only) of the HISCREW's top enclosure panel.
exhaust (air compressor part only) of the HISCREW's top enclosure panel.

Fig.
Fig. A
A Fig.
Fig. B
B Fig.
Fig. C
C
Ventilating Ventilating
Exhaust outlet Ventilating Exhaust outlet Ventilating
Exhaust outlet duct Exhaust outlet duct
Exhaust outlet duct duct
Exhaust outlet
excluded
Dryerexcluded

Ventilating fan refer to Ventilating fan refer


Ventilating fan refer to Ventilating fan refer
table 1 below. to table 2 below.
table 1 below. to table 2 below.
Dryer

hh
Air intake Air Air
Air intake Use detachable. Air Air
Use detachable. intake intake
intake intake

Ventilating Ventilating
Exhaust outlet Ventilating Ventilating
Exhaust outlet Exhaust outlet duct Exhaust outlet duct
Exhaust outlet duct Exhaust outlet duct
built-in

Ventilating fan refer


Dryerbuilt-in

Ventilating fan refer Dryer


to table 3 below. Dryer Dryer
to table 3 below. exhaust Dryer
exhaust exhaust
Ventilating fan refer to Ventilating fan refer exhaust
Ventilating fan refer to Ventilating fan refer
Dryer

table 1 below. to table 2 below.


table 1 below. to table 2 below.

hh
Air intake Air Air
Air intake Use detachable. Air Air
Use detachable. intake intake
intake intake

■Ventilation
■Ventilation data
data
Air-cooled
Air-cooled series
series
(kW) 7.5 11 15 22 37 55 75 100 150
Item (kW) 7.5 11 15 22 37 55 75 100 150
Item
Heat generation MJ/h 33.1 47.3 63.2 90.8 154 226 306 406 650
Heat generation MJ/h 33.1 47.3 63.2 90.8 154 226 306 406 650
3
Air exhaust (air compressor) m3/min 20 28 28 55 75 100 150 200 180×2
Air exhaust (air compressor) m /min 20 28 28 55 75 100 150 200 180×2
Approx. temp. Rise (exhaust air) ˚C 25 25 35 25 31 35 30 31 30
Approx. temp. Rise (exhaust air) ˚C 25 25 35 25 31 35 30 31 30
Allowable pressure loss (exhaust duct) Pa 20
Allowable pressure loss (exhaust duct) Pa 20
3
Recommended fan capacity 1 m3/min 88 125 167 240 407 598 810 1,074 1,720
Recommended fan capacity 1 m /min 88 125 167 240 407 598 810 1,074 1,720
3
Recommended fan capacity 2 m3/min 23 32 32 63 86 115 173 230 207×2
Recommended fan capacity 2 m /min 23 32 32 63 86 115 173 230 207×2

Air-cooled
Air-cooled with
with built-in
built-in dryer
dryer series
series
(kW)
Item (kW) 7.5 11 15 22 37 55 75
Item 7.5 11 15 22 37 55 75
Heat generation MJ/h 36.4 52.3 69.9 104 175 251 352
Heat generation MJ/h 36.4 52.3 69.9 104 175 251 352
3
Air exhaust (air compressor) m3/min 20 28 28 55 75 100 150
Air exhaust (air compressor) m /min 20 28 28 55 75 100 150
3
Air exhaust (airf dryer) m3/min 10 18 18 30 50 30 30
Air exhaust (airf dryer) m /min 10 18 18 30 50 30 30
Approx. temp. Rise (exhaust air) ˚C 25 25 35 25 31 35 30
Approx. temp. Rise (exhaust air) ˚C 25 25 35 25 31 35 30
Externally allowable pressure loss Pa 20
Externally allowable pressure loss Pa 20
3
Recommended fan capacity 1 m3/min 96 138 185 276 464 664 932
Recommended fan capacity 1 m /min 96 138 185 276 464 664 932
3
Recommended fan capacity 2 m3/min 33 47 52 102 149 181 295
Recommended fan capacity 2 m /min 33 47 52 102 149 181 295
3
Recommended fan capacity 3 m3/min 10 15 20 39 62 66 122
Recommended fan capacity 3 m /min 10 15 20 39 62 66 122

Water-cooled
Water-cooled series
series
(kW) 22 37 55 75 100 125 150 160 190 200 240
Item (kW) 22 37 55 75 100 125 150 160 190 200 240
Item
Heat generation MJ/h 16.7 29.3 41.5 57 82.9 122 146 156 185 195 233
Heat generation MJ/h 16.7 29.3 41.5 57 82.9 122 146 156 185 195 233
3
Recommended fan capacity 1 m3/min 44 78 110 151 220 324 388 414 490 516 619
Recommended fan capacity 1 m /min 44 78 110 151 220 324 388 414 490 516 619

Water-cooled
Water-cooled with
with built-in
built-in dryer
dryer series
series
(kW)
(kW) 22 37 55 75
●Derivation
●Derivation of
of necessary
necessary ventilation
ventilation capacity
capacity
Item 22 37 55 75
Item
Heat generation MJ/h 30.1 50.7 66.5 103 Q:Necessary ventilation capacity m3/min
3
Heat generation MJ/h 30.1 50.7 66.5 103 n×H
n×H Q:Necessary ventilation capacity m /min
Recommended fan capacity 1
Recommended fan capacity 1
3
m3/min
m /min
80
80
134
134
176
176
273
273 Q=
Q= 0.00126×DT×60
H:Heat generation per unit MJ/h
H:Heat generation per unit MJ/h
Note: The recommended ventilator capacities hold true when the ambient temperature rise is repressed
Note: The recommended ventilator capacities hold true when the ambient temperature rise is repressed
0.00126×DT×60 n:The number of installed units
n:The number of installed units
to 5℃ and the static pressure is 0 Pa . For more detail, refer to the installation figure and the instruction manual, DT:Tolerable temperature rise ℃
to 5℃ and the static pressure is 0 Pa . For more detail, refer to the installation figure and the instruction manual,
   and plan your ventilation facility.
DT:Tolerable temperature rise ℃
   and plan your ventilation facility. (The highest tolerable temperature of the compressor
(The highest tolerable temperature of the compressor
− annually highest ambient temperature)
− annually highest ambient temperature)

18
18
China Indonesia Thailand
Hitachi (China) Ltd. Hitachi Asia Ltd. (Jakarta Office) Hitachi Asia (Thailand) Co., Ltd.
18th Floor Beijing Fortune Building 10th Floor, Mid Plaza 1, JL. Jend. 18th Floor, Ramaland Building, 952
5 Dong San Huan Bei Lu Sudirman Kav. 10-11, Jakarta 10220 Rama IV Road Bangrak, Bangkok 10500
Chao Yang District, TEL : +62 (21) 574-4313 TEL : +66 (2) 632-9292
Beijing 100004 FAX : +62 (21) 574-4312 FAX : +66 (2) 632-9299
TEL : +86 (10) 6590-8111
FAX : +86 (10) 6590-8110 Malaysia Vietnam
(Shanghai Office) Hitachi Asia (Malaysia) Sdn. Bhd. Hitachi Asia Ltd. (Ho Chi Minh City Office)
(Hitachi (Shanghai) Trading Co., Ltd.) Suite 17.3, Level 17, Menara IMC (Letter Box 7th Floor, The Landmark, 5B Ton Duc Thang
18th Floor, Rui Jin Building No.5) No. 8 Jalan Sultan Ismail, 50250, Street District 1, Ho Chi Minh City
No.205, Maoming Road (S) Kuala Lumpur TEL : +84 (8) 829-9725
Shanghai, 200020 TEL : +60 (3) 2031-8751 FAX : +84 (8) 829-9729
TEL : +86 (21) 6472-1002 FAX : +60 (3) 2031-8758 (Ha Noi Office)
FAX : +86 (21) 6472-4990 Sun Red River Bldg., 6th Floor,
(Guangzhou Branch) Philippines 23 Phan Chu Trinh Street
3406, Office Tower, CITIC Plaza Hitachi Asia Ltd. (Philippines Branch) Hoan Kiem District Hanoi
233 TianHe North Road, 25th Floor, Pacific Star Building, Cor. Makati & Sen. TEL : +84 (4) 933-3123
Guangzhou 510613 Gil. Puyat Ave., Makati, Metro Manila FAX : +84 (4) 933-3125
TEL : +86 (20) 8752-1289 TEL : +63 (2) 819-7528, -7529
FAX : +86 (20) 8752-1301 FAX : +63 (2) 819-7539

Hitachi East Asia Ltd. Singapore


4th Floor, North Tower World Hitachi Asia Ltd.
Finance Centre, Harbour City, Canton Power & Industrial Systems Group
Road, Tsim Sha Tsui, Kowloon Hong Kong. 24 Jurong Port Road, #03-05 Cwt Distripark,
TEL : +852 2735-9218 Office Block, Singapore 619097
FAX : +852 2735-6793 TEL : +65-6305-7400
FAX : +65-6305-7401
(Taipei Branch)
3rd Floor, Hung Kuo Building
No.167 Tun-Hwa North Road,
Taipei (105) Taiwan
TEL : +886 (2) 2718-3666
FAX : +886 (2) 2718-8180

Specifications in this catalog are subject to change with or without notice, as Hitachi continues to develop the latest technologies and products for its customers.

For further information, please contact your nearest sales representative.

ISO14001 ISO9001