QC Report
QC Report
QC Report
Description
Abrading,Washing and Application of Finalcoat for Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 5
V9501A .
Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes N/A N/A N/A N/A N/A
Abrasive: N/A
Air Quality for Undercoat water
Yes Salt level N/A Yes
Blasting/Painting washing
Batch: N/A
PAINT SYSTEM Primer Mid Coat Top Coat
1 Midcoat
st
2 Midcoat
nd
Batch:829010816
Hempel Paints Comp A
Best Before:01-2020
Batch:078055745
Hempel Paints Comp B
Best Before:05-2019
QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes Maintained
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
455 452 456 458 455 457 456 456 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes
8:30 AM 19 25 16 62 27
10:30 AM 21 28 19 59 29
2:00 PM 18 27.9 15 50 31
PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE
QG3 UTILITY
h includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 59-
POWER TOOL
N/A
TOTAL
Avg. DFT in µm
456 µm
Inter-coat Interval
Maintained
Coating Defects
No
Yes
Profile Tape
PAINTING INSPECTOR
DAILY PAINTING INSPECTION REPORT
Description
Abrading,Washing and Application of 1st Midcoat for Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel fo
V9501A .
Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes N/A N/A N/A N/A N/A
Abrasive: N/A
Air Quality for Undercoat water
Yes Salt level N/A Yes
Blasting/Painting washing
Batch: N/A
PAINT SYSTEM Primer Mid Coat Top Coat
1 Midcoat
st
2 Midcoat
nd
Batch:829010816
Hempel Paints Comp A
Best Before:01-2020
Batch:078055745
Hempel Paints Comp B
Best Before:05-2019
QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes Maintained
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
315 313 320 322 318 320 315 318 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes
8:30 AM 18.9 26 16 53 28
10:30 AM 20.1 27 19 61 30
PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE
QG3 UTILITY
hich includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for 59-
POWER TOOL
N/A
TOTAL
Avg. DFT in µm
318 µm
Inter-coat Interval
Maintained
Coating Defects
No
Yes
Profile Tape
PAINTING INSPECTOR
DAILY PAINTING INSPECTION REPORT
Description
Degreasing,High pressure washing,Blasting and Priming of Internal side which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Ves
59-V9501A .
Wash Degreasing ABRASIVE BLAST CLEAN Blast Profile HAND TOOL POWER TOO
Surface Preparation
Yes Yes Sa2.5 77 µm N/A N/A
Batch:829010816
Hempel Paints Comp A
Best Before:01-2020
Batch:078055745
Hempel Paints Comp B
Best Before:05-2019
QUALITY TESTS AS PER QG Dust level Grade Stripe Coats Inter-coat Interval
ITP Yes N/A
2
DFT Readings in µm Adhesion test Coating Defects
Visual
N/A
152 150 151 153 154 150 153 152 No
INSP’n RESULTS PAINTING REPAIRS PAINTING WORK REJECTED PAINTING WORK ACCEPTED Yes
8:30 AM 17.5 25 15 53 25
10:30 AM 19 27 16 55 26
2:00 PM 20 29 16 48 30.1
PAINT INSP’N REPORT PAINTING INSPECTED & PREPARED BY PAINTING CONTRACTOR INSPECTED & REVIEWED BY QATAR GAS
CONTRACTOR
POSITION PAINTING INSPECTOR PAINTING INSPECTOR
SIGNATURE
QG3 UTILITY
de which includes Shell,Top/Bottom Dish and Manway cover of Wet Air Receiver Vessel for
POWER TOOL
N/A
TOTAL
Avg. DFT in µm
152 µm
Inter-coat Interval
N/A
Coating Defects
No
Yes
Profile Tape
PAINTING INSPECTOR