Bulletin #25

SELF-CONTAINED
engineering

PRECISION
WATER COOLED EXCELLENT RETURN
ON INVESTMENT
CHILLERS • Each Budzar unit is designed to maximize
the productivity of your process. Budzar
quality and reliability provide excellent
value for each dollar invested

LOW-COST, SIMPLE
OPERATION AND
MAINTENANCE
• Scroll compressors feature hot gas
capacity control for precise temperature
control and extended equipment service
life under varying load conditions.
• A.S.M.E. Constructed steel shell and
copper tube chiller vessels and
evaporators are specifically selected for
optimum performance and efficiency
• Programmable Logic Controller provides:
Programmability
-Software
-Softwaremay maybebecustomized,
customized,
transferred
transferredfrom froma apersonal
personalcomputer
computer
and
andupdated
updatedvia viaprogramming
programmingkey key
Displayed Instrumentation Information
-Pump
-Pumpdischarge
dischargepressure
pressureand andflow
flow
-Compressor
-Compressorsuction suctionpressure,
pressure,
temperature
temperatureand andsuperheat
superheat
-Liquid
-Liquidrefrigerant
refrigeranttemperature
temperatureand andsub-
sub-
cooling
cooling
-Evaporator
-Evaporatorinlet inletand
andoutlet
outlettemperature
temperature
-Compressor
-Compressorpump pumpstatus
status
Controller Functions
-Selectable
-Selectablecontrolled
controlledparameter
parameter(supply
(supply
ororreturn
returntemperature)
temperature)
-Head
-Headpressure
pressurecontrol
controlvia
viafan
fanmotor
motor
cycling
cycling(air(aircooled
cooledunits)
units)
High Technology
-All
-Allalarm
alarmsituation,
situation,values
valuesofofthe the
monitored
monitoredparameters
parametersand andthe thestatus
statusofof
the
thecontrolled
controlleddevices
devicesarearesaved
savedfor for
service/maintenance
service/maintenance review
review
WP SERIES WATER COOLED CHILLERS -Troubleshooting
-Troubleshootinginformation
when
whencircumstances
informationis isdisplayed
circumstancesrequire
displayed
requireassistance
assistance
ICE WP Series Self-Contained Water-Cooled Chillers deliver the benefit of economical -The
-Thecontroller
controlleridentifies
identifiesmarginal
marginal
space utilization with the energy efficiency in a water-cooled condenser. The WP operating
operatingconditions
conditionsand andadjusts
adjustschille-
chiller-
operation
operation
Series Chiller incorporates a chiller pump and a separate process water pump that
minimizes process temperature gradients. The result enhances product consistency. QUICK AND EASY
INSTALLATION
The WP Series Chillers offer capacities from 10 to 40 nominal tons. This series is
designed for processes requiring chiller fluid temperatures from +20oF to +60oF. • Installation cost is lowered by combining
our chillers with water reservoir
Budzar also designs and manufactures specialized equipment for non-standard assemblies. Our units arrive at your plant
applications. Our engineers have extensive experience in process chilling and pre-piped and pre-wired.
heating applications for such industries as: chemical, petroleum, plastics rubber, • All units are factory tested prior to
paper, power, steel, food, and pharmaceutical. We take the time to understand shipment
your current and future needs and design a solution targeted at high quality and
fast payback.

process

TEMPERATURE control
SELF-CONTAINED WATER COOLED CHILLERS

WP SERIES WATER-COOLED CHILLERS

Model WP WP -1110 WP-1515 WP-1620 WP-2430 WP-3640

Capacity @ 50o LWT TONS 11 16.5 22 33 44


Scroll Compressor HP 10 15 20 30 (15 ea) 40 (4 at 10 hp)
Chiller Flow @ GPM/PSI 24/25 40/25 52/25 79/35 105/25
Chiller Pump HP 1 1.5 1.5 2 3
Process Flow GPM/PSI 24/50 40/50 70/58 79/50 154/53
Process Pump HP 3 5 5 7.5 7.5
Connections (NPT) Supply INCHES 1.5 2 2 2.5 3
Return INCHES 1.5 2 2 2 .5 3
o
Condenser (85 F Tower Water) GPM 30 48 52 75 105
Connections (NPT) INCHES 1.25 1.5 1.5 2 2.5
Nameplate Amps @ 460/3/60 29.4 39.2 43.5 61.4 86.3
Total Power Input kW 15.0 19.3 20.1 31.5 43.0
Unit Efficiency (EER) BTU/WATT 8.56 9.26 9.97 9.49 10.13
Holding Tank Size GALLON 150 150 150 220 350
Operating Weight (Approx.) LBS 3,400 3,600 3,750 4,600 6,750
Shipping Weight (Approx.) LBS 2,600 2,800 2,850 3,100 3,850
Dimensions (Approx.) L x W x H INCHES 92 x 38 x 73 92 x 38 x 73 92 x 38 x 73 92 x 50 x 73 115 x 50 x 73

o o o o o
Note: All data based upon cooling water from 60 F to 50 F with 85 F @ 85 F condenser entering water with 10 F rise.
Increase capacity 10% for water cooled
Budzar Industries reserves the right to discontinue or change specifications without notice,
consistent with sound engineering practice and current industrial standards.

38241 Willoughby Pkwy., Willoughby, Ohio 44094-7582


(440) 918-0505 • Fax (440) 918-0606 / 918-0707
www.budzar.com • E-mail: sales@budzar.com Bulletin #25
10/03

You might also like