Design of Fall at RD 29.250 of RB Upper/Dy
Design of Fall at RD 29.250 of RB Upper/Dy
Design of Fall at RD 29.250 of RB Upper/Dy
250 OF RB UPPER/DY
1.HYDRAULIC PARTICULARS:
1. Full supply diascharge u/s 0.871 CUMEC
2. Full supply diascharge d/s 0.670 CUMEC
3. Drop HL 0.339 m
4. Full supply level u/s 168.192 m
5. Full supply level d/s 167.853 m
6. Full supply depth u/s D 0.863 m
7. Full supply depth d/s D 0.579 m
8. Bed level u/s CBL 167.329 m
9. Bed level d/s CBL 167.274 m
10. Bed width u/s U/S 0.229 m
11. Bed width d/s D/S 1.798 m
12. Assume Bligh coefficient BLC 7
13. Side slope 1.25 :1
14. Safe exit gradient 0.17
DESIGN
1. Length of crest
In case of vertical drop falls, the length of crest should be the same as the .
bed width of the channel
A
Depth of sheet piles from scour considerations :
Discharge intensity 'q' = 0.37
cumec/m
Depth of scour 'R' = 1.36{q2/f}1/3 = 0.70
m
Anticipated scour = 1.25 R = 0.88
m
R.L. of the bottom of scour hole = #NAME?
- 0.88
= #NAME?
m
(where yd is water depth
Minimum depth of u/s cutoff below bed level = yd/3+0.60
im m at u/s )
= #NAME? + 0.60
= #NAME? m
RL of the bottom of sheet pile = #NAME? m
Provide sheet pile bottom elevation at = #NAME? m
If U/S sheet bottom El. is above Cistern level then provide El.= ### m
D/S sheet pile :
Discharge intensity 'q' = 0.37 cumec/m
Depth of scour 'R' = 1.36{q2/f}1/3 = 0.70 m
Anticipated scour = 1.5 R = 1.06 m
d = 167.27 - 57.15
= 110.12 m
b = 8.60 m
110.12
d/b= = 12.81 = I/ a
8.60
The downstream floor concrete shall overlaid by 0.2 m thick brick pitching
Depth of up stream cut off ###
Downstream Protection
(a). Bed Protection
Length of bed protection = 3*d/s water depth
= 1.74 m
#NAME? 57.15
1.70 1.60 1.60 1.60
2.10 6.50
8.60
Note:-
1) Drawing is not to the scale. 5) Top of the crest shall be capped with 1:2:4 cement conc. 0.20 m thick.
2) All dimensions are in metre. 6) Brick pitching equal to US FSD ,laid sloping down 1 in 10 towards the crest in US.
3) In impervious floor, the grade of cement concrete is 1:3:6 (M10) with 7) U/S wing walls may be splayed straight at 45 0from the US edge &
0.15m top c. conc. 1:2:4 (M15), over laid with 0.20m brick pitching. D/S wings shall be straight,parallel & vertical.
4) Curtain walls 0.40m thick in CM 1:4 with 0.30m th CC 1:3:6 foundation. 8) D/S bed shall be protected by 20 cm dry brick pitching(one brick on
edge &one flat) on 10 cm ballast,it is not required in lined canals.