Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Lenovo Storage V3700 V2 and V3700 V2 XP: Product Guide

Download as pdf or txt
Download as pdf or txt
You are on page 1of 31
At a glance
Powered by AI
The key takeaways are that the Lenovo Storage V3700 V2 and V3700 V2 XP provide affordable consolidated storage for small and mid-sized organizations with advanced software capabilities. They can scale up to 4.055 PB and support a variety of host and drive connectivity options.

The main features and benefits include scalable modular storage, flexible host connectivity options, support for up to 264 drives and 10 expansion enclosures, flexibility in drive types, and integrated software functions.

The Lenovo Storage V3700 V2 and V3700 V2 XP systems can be scaled up to 4.055 PB of raw storage capacity by attaching up to 10 expansion enclosures supporting additional drives. They also allow scaling storage performance by adding faster SAS SSDs or HDDs.

Lenovo Storage V3700 V2 and V3700 V2 XP

Product Guide

Lenovo Storage V3700 V2 and V3700 V2 XP (Machine Type 6535) are members of the Lenovo Storage V
Series family of disk systems. By using IBM Spectrum Virtualize software functions, interoperability, and
management tools, Lenovo Storage V3700 V2 and V3700 V2 XP deliver innovation and new levels of
storage efficiency with ease of use in an entry-level disk system to enable organizations to overcome their
storage challenges.
Lenovo Storage V3700 V2 and V3700 V2 XP storage systems feature two node canisters, with 8 GB cache
per canister, upgradeable to 16 GB per canister (V3700 XP only), in a compact, 2U, 19-inch rack mount
enclosure. 12 Gb SAS (V3700 V2 XP only) and 1 Gb iSCSI connectivity is standard, with an option for
additional 1 Gb iSCSI, 12 Gb SAS, 16 Gb Fibre Channel (FC), 10 Gb iSCSI or Fibre Channel over Ethernet
(FCoE), or 25 Gb iSCSI connectivity.
Lenovo Storage V3700 V2 and V3700 V2 XP support up to 264 drives with up to ten expansion enclosures.
They also offer flexible drive configurations with the choice of 2.5-in. and 3.5-in. form factors, 10 K or 15 K
rpm SAS and 7.2 K rpm NL SAS hard disk drives (HDDs), and SAS solid-state drives (SSDs). The Lenovo
Storage V3700 V2 and V3700 V2 XP enclosures are shown in the following figure.

Figure 1. Lenovo Storage V3700 V2 and V3700 V2 XP SFF (top) and LFF (bottom) enclosures

Did you know?


Lenovo Storage V3700 V2 and V3700 V2 XP provide small and midsized organizations with the ability to
consolidate and share data at an affordable price, while utilizing advanced software capabilities that often
are found in more expensive systems.
Lenovo Storage V3700 V2 and V3700 V2 XP can be scaled up to 4.055 PB of raw storage capacity.
Lenovo Storage V3700 V2 offers hybrid block storage connectivity with support for 1 Gb iSCSI and 12 Gb
SAS, 10 Gb iSCSI or FCoE, 25 Gb iSCSI, or 16 Gb FC host connectivity at the same time. With Lenovo
Storage V3700 V2 XP 12 Gb SAS, 1 Gb iSCSI, and 10 Gb iSCSI or FCoE, 25 Gb iSCSI, or 16 Gb FC can be
used simultaneously.

Click here to check for updates

Lenovo Storage V3700 V2 and V3700 V2 XP 1


Key features
The Lenovo Storage V3700 V2 and V3700 V2 XP storage systems provide the following key features and
benefits:
Scalable, modular storage with dual-active intelligent array node canisters with 8 GB (V3700 V2) or
up to 16 GB (V3700 V2 XP) cache per canister.
Flexible host connectivity to match diverse client needs with support for 12 Gb SAS (V3700 V2 XP)
and 1 Gb iSCSI connectivity standard, with optional 10 Gb iSCSI or FCoE, 25 Gb iSCSI, 16 Gb FC,
or extra 12 Gb SAS or 1 Gb iSCSI connectivity.
12 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) or 24x 2.5-
inch small form factor (SFF) drives in the control enclosure; scalable up to 132 LFF drives per
system with the attachment of up to 10 LFF expansion enclosures (12x LFF drives each) or up to
264 SFF drives per system with the attachment of up to 10 SFF expansion enclosures (24x SFF
drives each) to satisfy growing needs for storage capacity and performance.
Flexibility in storing data on high-performance SAS SSDs, performance-optimized enterprise SAS
HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form
factors within a single system to perfectly meet performance and capacity requirements for various
workloads.
Rich set of standard functions are available at no extra cost, including virtualized internal storage,
thin provisioning, data reduction pools, one-way data migration, FlashCopy snapshots (up to 64
targets), and embedded GUI.
Optional licensed functions, including higher number of FlashCopy snapshots, Easy Tier, encryption
(V3700 V2 XP only), and Remote Mirroring.
VMware vSphere Virtual Volumes (VVol) integration brings advanced storage management functions
to the virtual machine level for finer VM storage service level control and policy-driven automation.
Note: VVol integration feature requires Spectrum Connect that can be downloaded from
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/v3700v2/6535/downloads
Intuitive, web-based GUI for easy system set up and management.
Extensive interoperability with support for most major server platforms and operating systems.
Lenovo Storage V Series systems that are based on Spectrum Virtualize software provide five 9’s
(99.999%) availability which means an average annual downtime of less than five minutes.
The Lenovo Storage V3700 V2 and V3700 V2 XP support the complete range of data storage requirements,
from highly utilized applications to high-capacity, low usage applications, with the flexible choice of drives.
The following 2.5-inch drives are supported:
High-performance SSDs: 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS
Read-optimized SSDs: 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB SAS
Performance-optimized, enterprise class disk drives:
300 GB, 600 GB, and 900 GB 15K rpm SAS
900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS
High-capacity, archival-class nearline disk drives: 2 TB 7.2K rpm NL SAS
The following 3.5-inch drives are supported:
Performance-optimized, enterprise class disk drives:
300 GB, 600 GB, and 900 GB 15K rpm SAS
900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS
High-capacity, archival-class nearline disk drives: 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm
NL SAS

Lenovo Storage V3700 V2 and V3700 V2 XP 2


All drives are dual-port and hot-swappable. Drives of the same form factor can be intermixed within the
appropriate enclosure, which provides the flexibility to address performance and capacity needs within a
single enclosure.
Up to ten Lenovo Storage V3700 V2 expansion enclosures are supported by a single Lenovo
Storage V3700 V2 or V3700 V2 XP control enclosure. Customers can intermix 3.5-inch and 2.5-inch
expansion enclosures behind a 3.5-inch or 2.5-inch control enclosure. This configuration delivers the
added flexibility to mix 3.5-inch and 2.5-inch drives within a single system (but not within the
enclosure). More drives and expansion enclosures are designed to be dynamically added with virtually no
downtime, which helps to quickly and seamlessly respond to ever-growing capacity demands.
The Lenovo Storage V3700 V2 and V3700 V2 XP storage systems are designed to offer high levels of
system and data availability with the following technologies:
Dual-active, intelligent node canisters with mirrored cache
Dual-port drives with automatic drive failure detection and RAID rebuild with global hot spares
Redundant hardware, including power supplies and fans
Hot-swappable and customer replaceable components
Automated path failover support for the data path between the server and the drives

Components and connectors


The following figure shows the front of the Lenovo Storage V3700 V2 or V3700 V2 XP SFF enclosure.

Figure 2. Front view of the Lenovo Storage V3700 V2 or V3700 V2 XP SFF enclosure
The following figure shows the front of the Lenovo Storage V3700 V2 or V3700 V2 XP LFF enclosure.

Figure 3. Front view of the Lenovo Storage V3700 V2 or V3700 V2 XP LFF enclosure

Lenovo Storage V3700 V2 and V3700 V2 XP 3


The following figure shows the rear of the Lenovo Storage V3700 V2 Control Enclosure.

Figure 4. Rear view of the Lenovo Storage V3700 V2 Control Enclosure

Lenovo Storage V3700 V2 and V3700 V2 XP 4


The following figure shows the rear view of the Lenovo Storage V3700 V2 XP Control Enclosure.

Figure 5. Rear view of the Lenovo Storage V3700 V2 XP Control Enclosure


The following figure shows the rear of the Lenovo Storage V3700 V2 Expansion Enclosure.

Figure 6. Rear view of the Lenovo Storage V3700 V2 Expansion Enclosure

Lenovo Storage V3700 V2 and V3700 V2 XP 5


System specifications
The following table lists the Lenovo Storage V3700 V2 and V3700 V2 XP storage system specifications.
Note: The supported hardware options and software features listed in this product guide are based on the
Spectrum Virtualize software version 8.1.3. For details about specific Spectrum Virtualize software releases
that introduced support for certain hardware options and software features, refer to the Readme file for the
particular software release that can be found at:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v3700v2/6535/downloads.

Table 1. System specifications


Component Specification
Form factor Lenovo Storage V3700 V2 Control Enclosure: 2U rack mount
Lenovo Storage V3700 V2 XP Control Enclosure: 2U rack mount
Lenovo Storage V3700 V2 Expansion Enclosure: 2U rack mount
Controller Dual controller (known as node canister) configuration.
configuration
RAID levels RAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6.
Controller cache 16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per
node canister). Cache mirroring between the node canisters. Flash-backed cache protection
(includes battery).
Drive bays Up to 264 SFF drive bays per storage system:
24 SFF drive bays in the control enclosure
24 SFF drive bays in the expansion enclosure; up to 10 expansion enclosures

Up to 132 LFF drive bays per storage system:


12 LFF drive bays in the control enclosure
12 LFF drive bays in the expansion enclosures; up to 10 expansion enclosures

Intermix of SFF and LFF enclosures is supported.


Drive technology SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported.
Drive Dual-ported 12 Gb SAS drive attachment infrastructure.
connectivity
Controller unit with two node canisters (ports per one node canister):
24x 12 Gb SAS internal drive ports (SFF enclosure)
12x 12 Gb SAS internal drive ports (LFF enclosure)
1x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of the
expansion enclosures

Expansion unit with two expansion canisters (ports per one expansion canister):
24x 12 Gb SAS internal drive ports (SFF enclosure)
12x 12 Gb SAS internal drive ports (LFF enclosure)
2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained
attachment of the expansion enclosures
Drives SFF drives:
300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs
900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs
2 TB 7.2K rpm NL SAS HDDs
400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB read-optimized SAS SSDs

LFF drives:
300 GB, 600 GB, and 900 GB 15K rpm SAS HDDs
900 GB, 1.2 TB, 1.8 TB, and 2.4 TB 10K rpm SAS HDDs
4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm NL SAS HDDs

Lenovo Storage V3700 V2 and V3700 V2 XP 6


Component Specification
Storage capacity Up to 4.055 PB (264x 15.36 TB SAS SSDs)
Host connectivity Standard ports (per control enclosure with two node canisters):
4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700
V2 XP only)

Optional additional ports on host interface cards (per control enclosure with two node
canisters):
8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)
4x 25 Gb iSCSI (RoCE) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
4x 25 Gb iSCSI (iWARP) SFP28 host ports (SW fiber, LC) (2 ports per node canister)
Host operating Microsoft Windows Server 2012, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7;
systems^ SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, 6.0, and 6.5.
Standard Virtualization of internal storage, Thin Provisioning, Data reduction pools, One-way Data
software features Migration, FlashCopy snapshots (up to 64 targets), and Embedded GUI.
Optional FlashCopy snapshots upgrade (up to 2048 targets), Easy Tier, Encryption (V3700 XP only), and
software features Remote Mirroring.
Performance Up to 168 000 / 390 000 cache read IOPS
(V3700 V2 / Up to 65 000 / 114 000 disk read IOPS
V3700 V2 XP)* Up to 17 000 / 29 000 disk write IOPS
Up to 32 000 / 54 000 disk mixed (70% read/30% write) IOPS
Up to 4.2 / 6.3 GBps sequential disk read throughput
Up to 1.1 / 1.7 GBps sequential disk write throughput
Configuration Per system:
maximums** Maximum number of storage pools: 1024
Maximum number of logical volumes: 2048
Maximum logical volume size: 256 TB
Maximum number of drives in a RAID array: 16
Maximum number of RAID arrays: 128
Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares)
Maximum number of distributed RAID arrays: 10
Maximum hot spare drives: No limit
Maximum number of host ports: 2048
Maximum number of hosts: 256
Maximum number of host ports per one host: 32
Maximum number of snapshots: 2048 (requires an optional license)
Maximum number of remote mirroring relationships: 2048 (requires an optional license)
Cooling Redundant cooling with the fan modules that are built into power supplies.
Power supply Two redundant hot-swap 800 W AC power supplies.
Hot-swap parts Node canisters, expansion canisters, SFP+/SFP28 transceivers, drives, power supplies with
fans.
Management 2x 1 GbE ports (UTP, RJ-45) in a primary/redundant configuration.
interfaces Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.
Security features Secure Socket Layer (SSL), Secure Shell (SSH), user level security, LDAP authentication
Warranty Three-year customer-replaceable unit and onsite warranty with 9x5 next business day
terms. Optional warranty service upgrades are available through Lenovo: 24x7 coverage,
2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty
extensions, YourDrive YourData.

Lenovo Storage V3700 V2 and V3700 V2 XP 7


Component Specification
Dimensions Height: 87 mm (3.4 in.); width: 483 mm (19.0 in.); depth: 556 mm (21.9 in.)
Weight Control enclosure (fully configured): 26 kg (57.3 lb)
Expansion enclosure (fully configured): 26.7 kg (58.9 lb)
^ The operating systems shown are for Lenovo servers. The V3700 V2 might support other operating systems. For a full list of
supported operating systems, refer to the Lenovo Storage V3700 V2 Interoperability Matrix that can be found on the Lenovo
Storage V3700 V2 Documentation page:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v3700v2/6535/documentation.
* Internal performance measurements with SSDs.
** For a detailed list of configuration limits and restrictions for a specific version of the Spectrum Virtualize for Lenovo Storage
V3700 V2 Software, refer to the Lenovo Support website: http://support.lenovo.com

Control enclosures
The following table lists the models of the Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures.

Table 2. Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures


Part Machine Feature
Description number Type-Model code
Relationship models (Worldwide)
Lenovo Storage V3700 V2 LFF Control Enclosure 6535C1D 6535-HC1 AU3Z
Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2D 6535-HC4 AU40
Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3D 6535-HC2 AU41
Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535C4D 6535-HC5 AU42
Relationship models (PRC only)
Lenovo Storage V3700 V2 LFF Control Enclosure PRC 6535R1C 6535-HC1 AU3Z
Lenovo Storage V3700 V2 SFF Control Enclosure PRC 6535R2C 6535-HC4 AU40
Lenovo Storage V3700 V2 XP LFF Control Enclosure PRC 6535R3C 6535-HC2 AU41
Lenovo Storage V3700 V2 XP SFF Control Enclosure PRC 6535R4C 6535-HC5 AU42
TopSeller models (Worldwide)
Lenovo Storage V3700 V2 LFF Control Enclosure (Top Seller) 6535EC1 6535-HC1 AU3Z
Lenovo Storage V3700 V2 SFF Control Enclosure (Top Seller) 6535EC2 6535-HC4 AU40
Lenovo Storage V3700 V2 XP LFF Control Enclosure (Top Seller) 6535EC3 6535-HC2 AU41
Lenovo Storage V3700 V2 XP SFF Control Enclosure (Top Seller) 6535EC4 6535-HC5 AU42

The Lenovo Storage V3700 V2 or V3700 V2 XP control enclosure includes the following items:
One Lenovo Storage V3700 V2 LFF or SFF control enclosure
Two power supplies with cooling modules
Two node canisters
Rack mount hardware kit
Publications package
Note: The control enclosures come standard without power cords; the power cord option must be
purchased together with the enclosure (see Power supplies and cables for details).
The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures ship with two node canisters. A node
canister provides interfaces for host connectivity, management, and internal drives, and it runs storage
management and virtualization software.

Lenovo Storage V3700 V2 and V3700 V2 XP 8


Each Lenovo Storage V3700 V2 or V3700 V2 XP control enclosure ships with 16 GB of battery-backed
cache (8 GB per node canister). The Lenovo Storage V3700 V2 XP control enclosures can be upgraded to
32 GB (16 GB per node canister). The following table lists cache upgrade option.

Table 3. Cache upgrade for the Lenovo Storage V3700 V2 XP control enclosure
Maximum
quantity per
Part Feature one control
Description number code enclosure
Lenovo Storage V3700 V2 XP Cache Upgrade 01DC667 AU79 1

The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures ship with the following host
connectivity interfaces:
4x Gigabit Ethernet (RJ-45) ports (2 ports per node canister) for 1 Gb iSCSI host connectivity and
management
4x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (2 ports per node canister) for 12 Gb SAS direct
host attachments (V3700 V2 XP only)
Each node canister has one expansion slot for an optional host interface card (HIC). The following host
interfaces can be added to the Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures with
optional HICs (if HICs are used, two HICs of the same type are required per one control enclosure):
8x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (4 ports per HIC) for SAS connectivity
8x 1 GbE (RJ-45) ports (4 ports per HIC) for extra iSCSI connectivity (for a total of 12x 1 GbE ports
per control enclosure)
8x 10 GbE SFP+ ports (4 ports per HIC) with eight SW SFP+ optical transceivers (LC connectors)
installed (4 transceivers per HIC) for 10 Gb iSCSI or FCoE connectivity
8x 16 Gb FC SFP+ ports (4 ports per HIC) with eight SW SFP+ optical transceivers (LC connectors)
installed (4 transceivers per HIC) for FC connectivity (16 Gb FC LW SFP+ transceivers are available
for ordering as an option)
4x 25 GbE (RoCE) SFP28 ports (2 ports per HIC) with four SW SFP28 optical transceivers (LC
connectors) installed (2 transceivers per HIC) for 25 GbE iSCSI connectivity with support for RDMA
with RoCE v2
4x 25 GbE (iWARP) SFP28 ports (2 ports per HIC) with four SW SFP28 optical transceivers (LC
connectors) installed (2 transceivers per HIC) for 25 GbE iSCSI connectivity with support for RDMA
with iWARP
Configuration notes:
Both node canisters must have the same type of the host interface card installed, and both cards
must have SFP+/SFP28 modules of the same type.
25 Gb iSCSI host interface cards do not support FCoE.

Lenovo Storage V3700 V2 and V3700 V2 XP 9


The following tables list the available host port configurations for the Lenovo Storage V3700 V2 and V3700
V2 XP control enclosures.

Table 4. Lenovo Storage V3700 V2 host port configurations


Port type and total number of ports
12 Gb SAS 1 Gb iSCSI 10 Gb iSCSI or FCoE 25 Gb iSCSI 16 Gb FC
(RoCE or iWARP)
Lenovo Storage V3700 V2 standard configuration
- 4 (2 per node canister) - - -
Lenovo Storage V3700 V2 optional configurations
8 (4 per node canister) 4 (2 per node canister) - - -
- 12 (6 per node canister) - - -
- 4 (2 per node canister) 8 (4 per node canister) - -
- 4 (2 per node canister) - 4 (2 per node canister) -
- 4 (2 per node canister) - - 8 (4 per node
canister)

Table 5. Lenovo Storage V3700 V2 XP host port configurations


Port type and total number of ports
12 Gb SAS 1 Gb iSCSI 10 Gb iSCSI or FCoE 25 Gb iSCSI 16 Gb FC
(RoCE or iWARP)
Lenovo Storage V3700 V2 XP standard configuration
4 (2 per node canister) 4 (2 per node canister) - - -
Lenovo Storage V3700 V2 XP optional configurations
12 (6 per node canister) 4 (2 per node canister) - - -
4 (2 per node canister) 12 (6 per node canister) - - -
4 (2 per node canister) 4 (2 per node canister) 8 (4 per node canister) - -
4 (2 per node canister) 4 (2 per node canister) - 4 (2 per node canister) -
4 (2 per node canister) 4 (2 per node canister) - - 8 (4 per node
canister)

The following table lists ordering information for the host connectivity options that are supported with the
Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures.

Table 6. Host connectivity options


Maximum
quantity per
Part Feature control
Description number code enclosure
Host connectivity card options
Lenovo Storage V3700 V2 2x 4-port 12Gb SAS Adapter Cards (mSAS HD) 01DC657 AU49 1
Lenovo Storage V3700 V2 2x 4-port 16Gb FC SFP+ Adapter Cards 01DC659 AU4B 1
(with SW SFP+ transceivers installed in all ports)
Lenovo Storage V3700 V2 2x 4-port 1GbE Adapter Cards (RJ-45) 01DC661 AU4D 1

Lenovo Storage V3700 V2 and V3700 V2 XP 10


Maximum
quantity per
Part Feature control
Description number code enclosure
Lenovo Storage V3700 V2 2x 4-port 10GbE SFP+ Adapter Cards 01DC663 AU4F 1
(with SW SFP+ transceivers installed in all ports)
Lenovo Storage V3700 V2 25GbE (RoCE) Adapter Pair 00YK990 B2UU 1
(with SW SFP28 transceivers installed in all ports)
Lenovo Storage V3700 V2 25GbE (iWARP) Adapter Pair 00YK991 B2UV 1
(with SW SFP28 transceivers installed in all ports)
SFP+ options for 16 Gb FC host interface card (the card ships with four 16 Gb FC SW SFP+ transceivers)
Lenovo Storage V3700 V2 16Gb FC LW SFP Transceivers (Pair) 01DC665 AU77 4*
Lenovo Networking cable options for FC, FCoE, 10 Gb iSCSI, and 25 Gb iSCSI host connectivity
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 8
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 8
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 8
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 8
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 8
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 8
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 8
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 8
Lenovo Storage V3700 V2 cable options for FC, FCoE, 10 Gb iSCSI, and 25 GbE iSCSI host connectivity
Lenovo Storage V3700 V2 1m OM3 Fiber Cable (LC) 01PG244 B2YH 8
Lenovo Storage V3700 V2 5m OM3 Fiber Cable (LC) 01PG245 B2YJ 8
Lenovo Storage V3700 V2 10m OM3 Fiber Cable (LC) 01DC687 AU51 8
Lenovo Storage V3700 V2 25m OM3 Fiber Cable (LC) 01PG246 B2YK 8
Lenovo Storage V3700 V2 cable options for FC, FCoE, and 10 Gb iSCSI host connectivity
Lenovo Storage V3700 V2 1m Fiber Cable (LC) 01DC681 AU4V 8
Lenovo Storage V3700 V2 5m Fiber Cable (LC) 01DC683 AU4X 8
Lenovo Storage V3700 V2 25m Fiber Cable (LC) 01DC685 AU4Z 8
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS (host)
Lenovo Storage V3700 V2 0.6m SAS Cable (mSAS) 01DC669 AU4H 8 / 12**
Lenovo Storage V3700 V2 1.5m SAS Cable (mSAS) 01DC671 AU4K 8 / 12**
Lenovo Storage V3700 V2 3m SAS Cable (mSAS) 01DC673 AU4M 8 / 12**
SAS host connectivity cables - Mini-SAS HD (controller) to Mini-SAS HD (host)
Lenovo Storage V3700 V2 0.6m 12Gb SAS Cable (mSAS HD) 01DC675 AU4P 8 / 12**
Lenovo Storage V3700 V2 1.5m 12Gb SAS Cable (mSAS HD) 01DC677 AU4R 8 / 12**
Lenovo Storage V3700 V2 3m 12Gb SAS Cable (mSAS HD) 01DC679 AU4T 8 / 12**
* Up to two LW SFP+ module pairs per 16 Gb FC host interface card in the node canister; both node canisters must have the
same connectivity type. The LW SFP+ modules replace the SW SFP+ modules that ship standard with the 16 Gb FC HIC.
** Maximum quantity shown is for models without / with integrated 12 Gb SAS host ports.

The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures provide 12 Gb SAS internal dual-port
drive connectivity, and each control enclosure also has two 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports
(1 port per node canister) for 12 Gb SAS expansion enclosure connectivity.

Lenovo Storage V3700 V2 and V3700 V2 XP 11


Expansion enclosures
The Lenovo Storage V3700 V2 and V3700 V2 XP control enclosures supports attachment of up to ten
Lenovo Storage V3700 V2 expansion enclosures. Intermix of LFF and SFF enclosures is supported. The
enclosures can be added to the system non-disruptively.
The following table lists the models of the Lenovo Storage V3700 V2 expansion enclosures.

Table 7. Lenovo Storage V3700 V2 expansion enclosures


Part Machine Feature
Description number Type-Model code
Relationship models (Worldwide)
Lenovo Storage V3700 V2 LFF Expansion Enclosure 6535N1F 6535-HC7 AU43
Lenovo Storage V3700 V2 SFF Expansion Enclosure 6535N2F 6535-HC8 AU44
Relationship models (PRC only)
Lenovo Storage V3700 V2 LFF Expansion Enclosure PRC 6535R1E 6535-HC7 AU43
Lenovo Storage V3700 V2 SFF Expansion Enclosure PRC 6535R2E 6535-HC8 AU44
TopSeller models (Worldwide)
Lenovo Storage V3700 V2 LFF Expansion Enclosure (Top Seller) 6535EN1 6535-HC7 AU43
Lenovo Storage V3700 V2 SFF Expansion Enclosure (Top Seller) 6535EN2 6535-HC8 AU44

The expansion enclosures include the following items:


One Lenovo Storage V3700 V2 LFF or SFF expansion enclosure
Two power supplies with cooling modules
Two expansion canisters
Rack mount hardware kit
Publications package
Note: The expansion enclosures come standard without power cords; the power cord option must be
purchased together with the enclosure (see Power supplies and cables for details).
Each Lenovo Storage V3700 V2 expansion enclosure ships with two expansion canisters. Each expansion
canister provides 12 Gb SAS connectivity to the internal drives and two external 12 Gb SAS x4 ports (Mini-
SAS HD SFF-8644 connectors labelled Port 1 and Port 2) that are used for connections to the Lenovo
Storage V3700 V2 or V3700 V2 XP node canisters and for daisy chaining the expansion enclosures
between each other. The expansion port (Port 1) on the left and right node canisters is connected to the
Port 1 on the left and right expansion canisters, respectively. The Port 2 on the left and right expansion
canisters is connected to the Port 1 on the left and right expansion canisters in the adjacent enclosure,
respectively, and so on.

Lenovo Storage V3700 V2 and V3700 V2 XP 12


The expansion enclosure connectivity topology is shown in the following figure.

Figure 7. Expansion unit connectivity topology


The following table lists ordering information for the connectivity options that are supported with the
expansion enclosures.

Table 8. Expansion unit connectivity options


Quantity per
one
Part Feature expansion
Description number code enclosure
Lenovo Storage V3700 V2 0.6m 12Gb SAS Cable (mSAS HD) 01DC675 AU4P 2*
Lenovo Storage V3700 V2 1.5m 12Gb SAS Cable (mSAS HD) 01DC677 AU4R 2*
Lenovo Storage V3700 V2 3m 12Gb SAS Cable (mSAS HD) 01DC679 AU4T 2*
* One cable per expansion canister; two cables are required per each expansion enclosure.

Drives
The Lenovo Storage V3700 V2 and V3700 V2 XP LFF control and expansion enclosures support up to 12
LFF hot-swap drives, and the SFF enclosures support up to 24 SFF hot-swap drives.
The following table lists drive options that are supported with the Lenovo Storage V3700 V2 and V3700 V2
XP LFF enclosures.

Table 9. LFF drive options


Maximum
quantity per
Part Feature one LFF
Description number code enclosure
3.5-inch 12 Gbps SAS hot-swap HDDs
Lenovo Storage V3700 V2 300GB 3.5" 15K HDD 01DE331 AU65 12
Lenovo Storage V3700 V2 600GB 3.5" 15K HDD 01DE333 AU66 12
Lenovo Storage V3700 V2 900GB 3.5" 10K HDD 01DE335 AU67 12
Lenovo Storage V3700 V2 900GB 15K RPM 3.5" HDD 01KP917 B0RF 12
Lenovo Storage V3700 V2 1.2TB 3.5" 10K HDD 01DE337 AU68 12

Lenovo Storage V3700 V2 and V3700 V2 XP 13


Maximum
quantity per
Part Feature one LFF
Description number code enclosure
Lenovo Storage V3700 V2 1.8TB 3.5" 10K HDD 01DE339 AU69 12
Lenovo Storage V3700 V2 2.4TB 3.5" 10K HDD 01KP970 B1JW 12
3.5-inch 12 Gbps NL SAS hot-swap HDDs
Lenovo Storage V3700 V2 4TB 3.5" 7.2K HDD 01DE341 AU6A 12
Lenovo Storage V3700 V2 6TB 3.5" 7.2K HDD 01DE343 AU6B 12
Lenovo Storage V3700 V2 8TB 3.5" 7.2K HDD 01DE345 AU6C 12
Lenovo Storage V3700 V2 10TB 7.2K 3.5" HDD 01KP894 AVW3 12
Lenovo Storage V3700 V2 12TB 7.2K 3.5" HDD 01PG414 B3SF 12

The following table lists drive options that are supported with the Lenovo Storage V3700 V2 and V3700 V2
XP SFF enclosures.

Table 10. SFF drive options


Maximum
quantity per
Part Feature one SFF
Description number code enclosure
2.5-inch 12 Gbps SAS hot-swap HDDs
Lenovo Storage V3700 V2 300GB 2.5" 15K HDD 01DE347 AU6D 24
Lenovo Storage V3700 V2 600GB 2.5" 15K HDD 01DE349 AU6E 24
Lenovo Storage V3700 V2 900GB 2.5" 10K HDD 01DE351 AU6F 24
Lenovo Storage V3700 V2 900GB 15K RPM 2.5" HDD 01KP916 B0RE 24
Lenovo Storage V3700 V2 1.2TB 2.5" 10K HDD 01DE353 AU6G 24
Lenovo Storage V3700 V2 1.8TB 2.5" 10K HDD 01DE355 AU6H 24
Lenovo Storage V3700 V2 2.4TB 2.5" 10K HDD 01KP969 B1JV 24
2.5-inch 12 Gbps NL SAS hot-swap HDDs
Lenovo Storage V3700 V2 2TB 2.5" 7.2K HDD 01DE357 AU6J 24
2.5-inch 12 Gbps SAS hot-swap SSDs
Lenovo Storage V3700 V2 400GB 2.5" Flash Drive 01DE359 AU6K 24
Lenovo Storage V3700 V2 800GB 2.5" Flash Drive 01DE361 AU6L 24
Lenovo Storage V3700 V2 1.6TB 2.5" Flash Drive 01DE363 AU6M 24
Lenovo Storage V3700 V2 3.2TB 2.5" Flash Drive 01DE365 AU6N 24
2.5-inch 12 Gbps SAS hot-swap SSDs - Read-optimized
Lenovo Storage V3700 V2 1.92TB 1DWD 2.5" SAS SSD 01CX802 AUDQ 24
Lenovo Storage V3700 V2 3.84TB 1DWD 2.5" SAS SSD 01GT345 AUK3 24
Lenovo Storage V3700 V2 7.68TB 2.5" RI Flash Drive 01KP494 AVW1 24
Lenovo Storage V3700 V2 15.36TB 2.5" RI Flash Drive 01KP495 AVW2 24

Lenovo Storage V3700 V2 and V3700 V2 XP 14


Software
The following software features are included with every Lenovo Storage V3700 V2 or V3700 V2 XP storage
system:
RAID levels 0, 1, 5, 6, and 10
Provides the flexibility to choose the level of data protection that is required.
Distributed RAID 5 and 6
Helps improve performance and availability with significantly faster rebuild time by allowing data to
be distributed across more physical drives that are used simultaneously.
Virtualization of internal storage
Enables rapid, flexible provisioning and simple configuration changes.
Thin Provisioning
Optimizes efficiency by allocating disk storage space in a flexible manner among multiple users,
based on the minimum space required by each user at any time. With thin provisioning, applications
use only the space they are actually using, not the total space that is allocated to them.
Data Reduction Pools
Help deliver consistent performance from compressed volumes and increase existing capacity
utilization by automatically de-allocating and reclaiming capacity of thin-provisioned volumes
containing deleted data and enabling this reclaimed capacity to be reused by other volumes.
One-way Data Migration
Enables easy and nondisruptive moves of volumes from another storage system onto the Lenovo
Storage V3700 V2 or V3700 V2 XP storage system by using FC or SAS connectivity.
FlashCopy
Enables creation of copies of data for backup, parallel processing, testing, and development, and
have the copies available almost immediately. Lenovo Storage V3700 V2 and V3700 V2 XP storage
systems support up to 64 targets per system at no charge.
Embedded GUI
Intuitive, web-based next-generation GUI for easy system set up and management.
The Lenovo Storage V3700 V2 and V3700 V2 XP storage capabilities can be expanded with optional
licensed functions. Each optional software function is licensed on a per-system basis and covers controller
enclosure and all attached expansion enclosures.
To help evaluate the benefits of these new capabilities, licensed functions (with the exception of FlashCopy
upgrade) can be enabled at no charge for a 90-day trial period. Trials are started from the Lenovo Storage
management GUI and do not require any Lenovo intervention. Upon expiration of the trial, the function is
automatically disabled unless a license key for that function was installed onto the machine.
The following optional licensed functions are available:
FlashCopy Upgrade
Enables creation of copies of data for backup, parallel processing, testing, and development, and
have the copies available almost immediately. Lenovo Storage V3700 V2 and V3700 V2 XP storage
systems support up to 64 targets per system at no charge. The FlashCopy upgrade option
increases this support to 2,048 FlashCopy targets per system.
Easy Tier
Storage tiering helps optimize storage use with data location to improve system performance,
reduce costs, and simplify management. Easy Tier automatically and dynamically moves frequently
accessed data to flash (solid-state) drives in the system, which results in flash drive performance
without manually creating and managing storage tier policies. Easy Tier makes it easy and
economical to deploy flash drives in the environment.

Lenovo Storage V3700 V2 and V3700 V2 XP 15


Encryption
The encryption feature is supported on the Lenovo Storage V3700 V2 XP system, and it provides
encryption for data at rest for enhanced data security. Encryption is performed by the V3700 V2 XP
control enclosure for data that is stored within the system (the control enclosure and all attached
expansion enclosures). Encryption feature does not require self-encrypting drives (SEDs); it works
with traditional drives. Encryption is enabled on the entire V3700 V2 XP system (the control
enclosure and all attached expansion enclosures).
Remote Mirroring
The remote mirroring feature provides storage system-based data replication by using synchronous
or asynchronous data transfers over IP, FC, or FCoE communication links:
Metro Mirror maintains a fully synchronized copy at metropolitan distances (up to 300 km).
Global Mirror operates asynchronously and helps maintain a copy at much greater distances
(up to 8000 km).
Both functions support VMware Site Recovery Manager for disaster recovery.
For ultimate flexibility, Lenovo Storage V3700 V2 and V3700 V2 XP remote mirroring interoperates
with any Lenovo Storage V Series, Storwize for Lenovo, or IBM Storwize family system, including
Storwize V3700, Storwize V7000, Storwize V5000, and SAN Volume Controller.
The remote mirroring option must be acquired (or licensed) for the primary (local) and secondary
(remote) systems. If the Lenovo Storage V3700 V2 or V3700 V2 XP is mirrored to another system,
the other system must have the appropriate and applicable license for remote mirroring.
The Lenovo Storage V3700 V2 and V3700 V2 XP support the following management interfaces:
Web-based graphical user interface (GUI) via HTTPS that requires only a supported browser
(Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate
console or plug-in
Command line interface (CLI) via SSH
Storage Management Initiative Specification (SMI-S)
SNMP and email notifications
The following tables list ordering information for optional software features for the Lenovo Storage
V3700 V2 and V3700 V2 XP.

Table 11. Optional software features for the Lenovo Storage V3700 V2
Maximum
Part Feature quantity per
Description number code system
Lenovo Storage V3700 V2 FlashCopy Upgrade Key Activation 01DE367 AU7D 1
Lenovo Storage V3700 V2 Remote Mirroring Key Activation 01DE369 AU7E 1
Lenovo Storage V3700 V2 Easy Tier Key Activation 01DE371 AU7F 1

Table 12. Optional software features for the Lenovo Storage V3700 V2 XP
Maximum
Part Feature quantity per
Description number code system
Lenovo Storage V3700 V2 XP FlashCopy Upgrade Key Activation 01DE373 AU7G 1
Lenovo Storage V3700 V2 XP Remote Mirroring Key Activation 01DE375 AU7H 1
Lenovo Storage V3700 V2 XP Easy Tier Key Activation 01DE377 AU7J 1

Lenovo Storage V3700 V2 and V3700 V2 XP 16


Encryption
The Lenovo Storage V3700 V2 XP supports encryption for data at rest. Encryption is performed by
the control enclosure for data stored within the system (the control enclosure and all attached expansion
enclosures). Encryption is enabled on Lenovo Storage V3700 V2 XP through the acquisition of the
Encryption Enablement feature. This feature enables encryption on the entire V3700 V2 XP system (control
enclosure and all attached expansion enclosures).
The Encryption USB Flash Drives (Four Pack) feature is required when the Encryption Enablement feature
is acquired. This feature provides four USB flash drives for storing the encryption master access key. This
feature can also be ordered if more USB flash drives are needed.
The following table lists ordering information for the encryption options.

Table 13. Lenovo Storage V3700 V2 XP encryption options


Maximum
quantity per
Part Feature one control
Description number code enclosure
Lenovo Storage V3700 V2 XP Encryption Enablement 01PG406 B2Z8 1
Lenovo Storage V3700 V2 XP Encryption USB Drive Pack 01PG407 B2Z9 1

Note: The Lenovo Storage V3700 V2 XP Encryption Enablement feature and the Encryption USB Drive
Pack feature are not available in the following countries:
Belarus
Kazakhstan
People's Republic of China
Russia

Lenovo Storage V3700 V2 and V3700 V2 XP 17


Power supplies and cables
The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures have two redundant hot-swap 800 W AC
power supplies, each with an IEC 320-C14 connector.
The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures ship standard without power cables. Rack
power cords or line cords should be ordered with the enclosures (see the following table; each part
number or feature code contains two power cords that are needed per one enclosure).

Table 14. Power cords


Part Feature
Description number code
Rack power cables
Lenovo Storage V3700 V2 2.0m, 10A/100-250V, C13/IEC 320-C14 2x Rack Power Cables 01DE209 AU5P
Line cords
Lenovo Storage V3700 V2 1.8m, 10A/120V, C13/NEMA 5-15P (US/CHI) 2x Line Cords 01DE223 AU63
Lenovo Storage V3700 V2 2.8m, 10A/110V, C13 to CNS 10917-3(TW) 2x Line Cords 01DE213 AU5T
Lenovo Storage V3700 V2 2.8m, 10A/120V, C13/NEMA 5-15P (US) 2x Line Cords 01DE211 AU5R
Lenovo Storage V3700 V2 2.8m, 10A/220V, C13 to GB 2099.1 (CN) 2x Line Cords 01DE207 AU5M
Lenovo Storage V3700 V2 2.8m, 10A/220V, C13 to IRAM 2073 (AR) 2x Line Cords 01DE205 AU5K
Lenovo Storage V3700 V2 2.8m, 10A/220V, C13 to NBR 6147 (BR) 2x Line Cords 01DE215 AU5V
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13 to BS 1363/A (UK) 2x Line Cords 01DC689 AU53
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13 to CEE7-VII (EUR) 2x Line Cords 01DC693 AU57
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13 to CEI 23-16 (IT) 2x Line Cords 01DE201 AU5F
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13 to DK2-5a (DK) 2x Line Cords 01DC695 AU59
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13 to SI 32 (Israel) 2x Line Cords 01DE203 AU5H
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13/AS/NZS 3112 (ANZ) 2x Line Cords 01DC691 AU55
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13/SABS 164 (SA) 2x Line Cords 01DC697 AU5B
Lenovo Storage V3700 V2 2.8m, 10A/230V, C13/SEV1011-S24507(SW) 2x Line Cords 01DC699 AU5D
Lenovo Storage V3700 V2 2.8m, 10A/240V, C13 to IS 6538 (India) 2x Line Cords 01DE217 AU5X
Lenovo Storage V3700 V2 2.8m, 12A/220V, C13 to KSC 8305 (KR) 2x Line Cords 01DE221 AU61
Lenovo Storage V3700 V2 4.3m, 12A/100V, C13 to JIS C-8303 (JP) 2x Line Cords 01DE219 AU5Z

Physical specifications
The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures have the following dimensions and weight
(approximate):
Height: 87 mm (3.4 in)
Width: 483 mm (19.0 in)
Depth: 556 mm (21.9 in)
Weight (fully configured):
Control Enclosure: 26 kg (57.3 lb)
Expansion Enclosure: 26.7 kg (58.9 lb)

Operating environment
Lenovo Storage V3700 V2 and V3700 V2 XP 18
Operating environment
The Lenovo Storage V3700 V2 and V3700 V2 XP enclosures are supported in the following environment:
Air temperature:
Operating: 10 °C - 35 °C (50 °F - 95 °F)
Non-operating: -10 °C - +50 °C (14 °F - 125 °F)
Maximum altitude: 3,050 m (10,006 ft)
Relative humidity:
Operating: 20% - 80% (non-condensing)
Non-operating: 8% - 80% (non-condensing)
Electrical power:
Voltage range: 100 V AC - 240 V AC
Frequency: 50 Hz - 60 Hz
Power consumption:
LFF Control Enclosure (V3700 V2): 331 watts
LFF Control Enclosure (V3700 V2 XP): 333 watts
LFF Expansion Enclosure: 231 watts
SFF Control Enclosure (V3700 V2): 333 watts
SFF Control Enclosure (V3700 V2 XP): 335 watts
SFF Expansion Enclosure: 233 watts
Heat dissipation (BTU per hour):
LFF Control Enclosure (V3700 V2): 1,129
LFF Control Enclosure (V3700 V2 XP): 1,136
LFF Expansion Enclosure: 788
SFF Control Enclosure (V3700 V2): 1,136
SFF Control Enclosure (V3700 V2 XP): 1,143
SFF Expansion Enclosure: 795
Acoustical noise emission:
LFF enclosure:
6.1 bels (idling)
6.1 bels (operating)
SFF enclosure:
6.2 bels (idling)
6.2 bels (operating)

Warranty services and upgrades


The Lenovo Storage V3700 V2 and V3700 V2 XP have a three-year Customer Replaceable Unit (CRU) and
onsite warranty with 9x5/next business day (NBD) terms.
Some countries might have different warranty terms and conditions than the standard warranty. This is due
to local business practices or laws in the specific country. Local service teams can assist in explaining
country-specific terms when needed. Examples of country-specific warranty terms are second or longer
business day parts delivery or parts-only base warranty.
If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will
dispatch a service technician to the customer site to perform the replacement. Onsite labor under base
warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units
(FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor
under base warranty.

Lenovo Storage V3700 V2 and V3700 V2 XP 19


If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement
parts that are under base warranty (including FRUs) that will be sent to a requested location for self-
service. Parts-only service does not include a service technician being dispatched onsite. Parts must be
changed at customer’s own cost and labor and defective parts must be returned following the instructions
supplied with the spares parts.
Also available are Lenovo Services warranty upgrades and post-warranty maintenance agreements, with a
well-defined scope of services, including service hours, response time, term of service, and service
agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are
available in every country. For information about Lenovo warranty service upgrade offerings that are
available in your country or area, refer to the following resources:
Service part numbers in Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com/#/services
Lenovo Services Availability Locator
http://lenovolocator.com/
In general, the following Lenovo warranty service upgrades are available:
Warranty and maintenance service upgrades:
3, 4, or 5 years of warranty service coverage
1-year or 2-year post-warranty extensions
Foundation Service: 9x5 service coverage with next business day onsite response
Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed
repair (available only in select countries)
Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed
repair (available only in select countries)
YourDrive YourData
Lenovo’s YourDrive YourData service (where applicable) is a multi-drive retention offering that
ensures your data is always under your control, regardless of the number of drives that are installed
in your Lenovo system. In the unlikely event of a drive failure, you retain possession of your drive
while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
The YourDrive YourData service can be purchased in convenient bundles with Foundation,
Essential, or Advanced Service upgrades and extensions.
Remote Technical Support
Remote Technical Support (RTS) provides comprehensive technical call center support for 1 or 3
years. RTS can reduce problem resolution time, which helps decrease the cost to address technical
problems and increase uptime.
Hardware Installation Services
Lenovo experts can seamlessly manage the physical installation of your server, storage, or
networking hardware. Working at a time convenient for you (business hours or off shift), the
technician will unpack and inspect the systems on your site, install options, mount in a rack
cabinet, connect to power and network, check and update firmware to the latest levels, verify
operation, and dispose of the packaging, allowing your team to focus on other priorities.
For service definitions, country-specific details, and service limitations, please refer to the following
documents:
Lenovo Statement of Limited Warranty for Data Center Group (DCG) Servers and System Storage
http://pcsupport.lenovo.com/us/en/solutions/ht503310
Lenovo Data Center Services Agreement
http://support.lenovo.com/us/en/solutions/ht116628

Lenovo Storage V3700 V2 and V3700 V2 XP 20


Regulatory compliance
The Lenovo Storage V3700 V2 and V3700 V2 XP conforms to the following regulations:
FCC: Verified to comply with Part 15 of the FCC Rules, Class A
Canada ICES-003, Class A
Australia and New Zealand Class A statement
European Union Council Directive 2004/108/EC
EN 55022, Class A
Japan VCCI Class A statement
People's Republic of China Class A statement
Taiwan Class A compliance statement
Korea KCC Class A statement
Russia EMI Class A statement
Mexico NOM

Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the
network. The Lenovo Storage V3700 V2 and V3700 V2 XP support attachment to Lenovo servers by using
SAS, iSCSI, FC, or FC over Ethernet (FCoE) storage connectivity protocols. Hybrid storage connectivity
also is supported.
Note: Tables that are provided in this section are for ordering reference purposes only. End-to-end storage
configuration support must be verified through the Lenovo Storage V3700 V2 Interoperability Matrix that
can be found on the Lenovo Storage V3700 V2 Documentation page:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/v3700v2/6535/documentation
SAS connectivity
The following table lists currently available SAS adapters for Lenovo servers that are compatible with the
Lenovo Storage V3700 V2 and V3700 V2 XP SAS storage (direct attach).

Table 15. SAS adapters


Description Part number
ThinkSystem SAS HBAs
ThinkSystem 430-8e SAS/SATA 12Gb HBA 7Y37A01090
ThinkSystem 430-16e SAS/SATA 12Gb HBA 7Y37A01091
System x SAS HBAs
6Gb SAS HBA 46M0907
N2125 SAS/SATA HBA (6Gb) 46C9010
N2225 SAS/SATA HBA (12Gb) 00AE912
N2226 SAS/SATA HBA (12Gb) 00AE916
ThinkServer SAS HBAs
Lenovo ThinkServer 9300-8e PCIe 12Gb 8 Port External SAS Adapter by LSI 4XB0F28703

FCoE or iSCSI connectivity


The Lenovo Storage V3700 V2 and V3700 V2 XP support end-to-end 10 Gb FCoE connectivity with native
FCoE ports or FCoE connectivity via FCoE/FC gateways with native FC ports. Lenovo RackSwitch™,
Brocade, and Cisco converged switches can be used to provide FCoE connectivity for the Lenovo
Storage V3700 V2 and V3700 V2 XP FC storage.

Lenovo Storage V3700 V2 and V3700 V2 XP 21


The Lenovo Storage V3700 V2 and V3700 V2 XP also support iSCSI attachments via standard 1 Gb, 10
Gb, or 25 Gb Ethernet network. Any compatible Ethernet switch, including Lenovo RackSwitch top of rack
(TOR) switches and integrated Flex System Ethernet I/O modules, can be used to provide iSCSI
connectivity for the Lenovo Storage V3700 V2 and V3700 V2 XP iSCSI storage.
With software iSCSI initiators, any supported 1 Gb, 10 Gb, or 25 Gb Ethernet adapter for Lenovo servers is
compatible with the Lenovo Storage V3700 V2 and V3700 V2 XP iSCSI storage.
Currently available converged FCoE/iSCSI adapters for Lenovo servers that are compatible with
the Lenovo Storage V3700 V2 and V3700 V2 XP are listed in the following table. Other HBAs also might be
supported (see the Interoperability Matrix for details).

Table 16. Converged FCoE/iSCSI adapters


Description Part number
System x converged adapters
QLogic 8200 Dual Port 10GbE SFP+ VFA (Requires 00Y5624) 90Y4600
System x FoD upgrades required for FCoE/iSCSI support
QLogic 8200 VFA FCoE/iSCSI License (FoD) (For 90Y4600) 00Y5624
Flex System converged adapters
Flex System CN4022 2-port 10Gb Converged Adapter 88Y5920
Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter (Requires 94Y5164) 94Y5160
Flex System FoD upgrades required for FCoE/iSCSI support
Flex System CN4058S Virtual Fabric Adapter SW Upgrade (FoD) (For 94Y5160) 94Y5164

Fibre Channel connectivity


The Lenovo Storage V3700 V2 and V3700 V2 XP support direct FC attachments and FC switch-based
attachments. Brocade and Cisco SAN switches can be used to provide FC connectivity for the Lenovo
Storage V3700 V2 FC storage.
Currently available FC adapters for Lenovo servers that are compatible with the Lenovo Storage V3700 V2
and V3700 V2 XP FC storage are listed in the following table. Other HBAs also might be supported (see the
Interoperability Matrix for details).

Table 17. Fibre Channel adapters


Description Part number
ThinkSystem HBAs: 32 Gb FC
ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 7ZT7A00517
ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 7ZT7A00519
ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 7ZT7A00516
ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 7ZT7A00518
System x HBAs: 16 Gb FC
Emulex 16Gb Gen6 FC Single-port HBA (LPe31000) 01CV830
Emulex 16Gb Gen6 FC Dual-port HBA (LPe31002) 01CV840
Emulex 16Gb FC Single-port HBA (LPe16000) 81Y1655
Emulex 16Gb FC Dual-port HBA (LPe16000) 81Y1662
QLogic 16Gb Enhanced Gen5 FC Single-port HBA (QLE2690) 01CV750
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA (QLE2692) 01CV760

Lenovo Storage V3700 V2 and V3700 V2 XP 22


Description Part number
QLogic 16Gb FC Single-port HBA (QLE2660) 00Y3337
QLogic 16Gb FC Dual-port HBA (QLE2662) 00Y3341
System x HBAs: 8 Gb FC
Emulex 8Gb FC Single-port HBA (LPe12000) 42D0485
Emulex 8Gb FC Dual-port HBA (LPe12002) 42D0494
QLogic 8Gb FC Single-port HBA (QLE2560) 42D0501
QLogic 8Gb FC Dual-port HBA (QLE2562) 42D0510
ThinkServer HBAs: 16 Gb FC
ThinkServer QLE2672 PCIe 16Gb 2 Port FC Adapter by QLogic 4XC0F28745
ThinkServer LPe16000B Single Port 16Gb FC HBA by Emulex 4XB0F28653
ThinkServer LPe16002B Dual Port 16Gb Fiber Channel HBA by Emulex 4XB0F28650
ThinkServer LPe16002B-M6-L PCIe 16Gb 2 Port FC HBA by Emulex 4XB0F28705
ThinkServer LPm16002-M6-L AnyFabric 16Gb 2 Port FC HBA by Emulex 4XB0F28706
ThinkServer HBAs: 8 Gb FC
ThinkServer QLE2562 Dual Port 8Gb Fibre Channel HBA by QLogic 0C19482
ThinkServer LPe16002B-M8-L PCIe 8Gb 2 Port FC HBA by Emulex 4XB0F28704
Flex System HBAs: 16 Gb FC
Flex System FC5052 2-port 16Gb FC Adapter 95Y2386
Flex System FC5054 4-port 16Gb FC Adapter 95Y2391
Flex System FC5172 2-port 16Gb FC Adapter 69Y1942
Flex System HBAs: 8 Gb FC
Flex System FC3052 2-port 8Gb FC Adapter 95Y2375
Flex System FC3172 2-port 8Gb FC Adapter 69Y1938

Networking switches
The following table lists currently available Ethernet and FC rack-mount switches that are currently offered
by Lenovo that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.

Table 18. Ethernet and FC rack-mount switches


Part
Description number
1 Gb Ethernet (iSCSI connectivity)
Lenovo RackSwitch G7028 (Rear to Front) 7159BAX
Lenovo RackSwitch G7052 (Rear to Front) 7159CAX
Lenovo RackSwitch G8052 (Rear to Front) 7159G52
10 Gb Ethernet (iSCSI connectivity)
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) 7159A1X
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) 7159B1X
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) 7159C1X
10 Gb Ethernet (iSCSI connectivity, FCoE transit switch)
Lenovo RackSwitch G8124E (Rear to Front) 7159BR6
Lenovo RackSwitch G8264 (Rear to Front) 7159G64

Lenovo Storage V3700 V2 and V3700 V2 XP 23


Part
Description number
Lenovo RackSwitch G8272 (Rear to Front) 7159CRW
Lenovo RackSwitch G8296 (Rear to Front) 7159GR6
25 Gb Ethernet (iSCSI connectivity)
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) 7159E1X
100 Gb Ethernet (4x 25 Gb Ethernet breakout connectivity out of a 100 Gb port; iSCSI connectivity)
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) 7159D1X
Converged 10 GbE and 8 Gb FC (iSCSI connectivity, FCoE/FC gateway, end-to-end FCoE)
Lenovo RackSwitch G8264CS (Rear to Front) 7159DRX
8 Gb FC
Lenovo B300, 8 ports activated w/ 8Gb SWL SFPs, 1 PS, Rail Kit 3873AR3
Lenovo B300, E_Port License included, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit 3873AR6
16 Gb FC
Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit 6559D2Y
Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit 6559D1Y
Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit 3873AR5
Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit 3873BR3
32 Gb FC
Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit 6559D3Y
Lenovo ThinkSystem DB620S, 24 ports activated, No SFPs, 2 PS, Rail Kit 6415G3A
Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit 6415G11
Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit 6415G2A
Lenovo ThinkSystem DB400D 32Gb FC Director, Up to 192 ports, 8U, Enterprise SW 6684B2A
Lenovo ThinkSystem DB800D 32Gb FC Director, Up to 384 ports, 14U, Enterprise SW 6682B1A

For more information, see the list of Product Guides in the following categories:
Top-of-rack Switches: http://lenovopress.com/servers/options/switches#rt=product-guide
Rack SAN Switches: http://lenovopress.com/storage/switches/rack#rt=product-guide

Lenovo Storage V3700 V2 and V3700 V2 XP 24


The following table lists currently available Ethernet and FC embedded switches and pass-thru modules for
Flex System that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.

Table 19. Ethernet and FC embedded switches for Flex System


Description Part number
1 Gb Ethernet (iSCSI connectivity)
Lenovo Flex System EN2092 1Gb Ethernet Scalable Switch 49Y4294
10 Gb Ethernet (iSCSI connectivity, FCoE transit switch)
Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch 00FM514
Lenovo Flex System SI4091 10Gb System Interconnect Module 00FE327
Lenovo Flex System Fabric SI4093 System Interconnect Module 00FM518
Cisco Nexus B22 Fabric Extender for Flex System* 94Y5350
Cisco Nexus B22 Fabric Extender with FET bundle for Flex System* 94Y5355
25 Gb Ethernet (iSCSI connectivity)
Lenovo ThinkSystem NE2552E Flex Switch 4SG7A08868
Converged 10 GbE and 8 Gb FC (iSCSI connectivity, FCoE/FC gateway, end-to-end FCoE)
Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch 00FM510
8 Gb FC
Lenovo Flex System FC3171 8Gb SAN Switch 69Y1930
16 Gb FC
Lenovo Flex System FC5022 16Gb SAN Scalable Switch 88Y6374
Lenovo Flex System FC5022 24-port 16Gb SAN Scalable Switch (includes two 16 Gb SFPs) 00Y3324
Lenovo Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch 90Y9356
Pass-thru modules (require a compatible external switch)
Lenovo Flex System EN4091 10Gb Ethernet Pass-thru 88Y6043
Lenovo Flex System FC3171 8Gb SAN Pass-thru 69Y1934
* Requires a supported Cisco Nexus top of rack switch.

For more information, see the list of Product Guides in the following categories:
Blade Network Modules: http://lenovopress.com/servers/blades/networkmodule#rt=product-guide
Blade Storage Modules: http://lenovopress.com/servers/blades/storagemodule#rt=product-guide

Lenovo Storage V3700 V2 and V3700 V2 XP 25


Operating systems
The Lenovo Storage V3700 V2 and V3700 V2 XP support host attachments to the System x servers,
ThinkServer systems, and Flex System compute nodes running the following operating systems:
Microsoft:
Microsoft Windows Server 2016
Microsoft Windows Server 2012 R2
Microsoft Windows Server 2012
Red Hat:
Red Hat Enterprise Linux 7 Update 3
Red Hat Enterprise Linux 7 Update 2
Red Hat Enterprise Linux 6 Update 7
Red Hat Enterprise Linux 6 Update 6
SUSE:
SUSE Linux Enterprise Server 12 SP1
SUSE Linux Enterprise Server 11 SP4
VMware:
VMware vSphere 6.5
VMware vSphere 6.0 Update 2
VMware vSphere 6.0 Update 1
VMware vSphere 5.5 Update 3
VMware vSphere 5.1 Update 3
Note: The operating systems shown are for Lenovo servers. The V3700 V2 might support other operating
systems. For a full list of supported operating systems, refer to the Lenovo Storage V3700 V2
Interoperability Matrix that can be found on the Lenovo Storage V3700 V2 Documentation page:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/v3700v2/6535/documentation

Rack cabinets
The following table lists the rack cabinets that are currently offered by Lenovo that can be used with
the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.

Table 20. Rack cabinets


Part
Description number
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072RX
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072PX
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) 93074RX
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) 93634PX
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) 93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) 93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments) 93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) 93084EX

For more information, see the list of Product Guides in the Rack cabinets category:
http://lenovopress.com/servers/options/racks

Lenovo Storage V3700 V2 and V3700 V2 XP 26


Power distribution units
The following table lists the power distribution units (PDUs) that are currently offered by Lenovo that can
be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.

Table 21. Power distribution units


Part
Description number
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 cord 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord 00YJ780
0U 18 C13/6 C19 Switched and Monitored 32A/200-240/346-415V/3Ph PDU w/ IEC60309 532P6 cord 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd line cord 46M4003
1U 12 C13 Switched and Monitored DPI PDU (without line cord) 46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord 46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord) 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord 71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord) 39M2816
DPI Single Phase C13 Enterprise PDU (without line cord) 39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord) 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord 39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord 39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) 00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord 39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P) 40K9614
DPI 32a Line Cord (IEC 309 P+N+G) 40K9612

Lenovo Storage V3700 V2 and V3700 V2 XP 27


Part
Description number
DPI 32a Line Cord (IEC 309 3P+N+G) 40K9611
DPI 60a Cord (IEC 309 2P+G) 40K9615
DPI 63a Cord (IEC 309 P+N+G) 40K9613
DPI Australian/NZ 3112 Line Cord (32A) 40K9617
DPI Korean 8305 Line Cord (30A) 40K9618

For more information, see the list of Product Guides in the Power Distribution Units category:
http://lenovopress.com/servers/options/pdu

Uninterruptible power supply units


The following table list the uninterruptible power supply (UPS) units that are currently offered by Lenovo
that can be used with the Lenovo Storage V3700 V2 and V3700 V2 XP in storage solutions.

Table 22. Uninterruptible power supply units


Part
Description number
Worldwide models
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) 55941AX
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) 55941KX
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) 55942AX
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55942KX
RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA5-20R 16A, 1x NEMA L5-30R 24A outlets) 55943AX
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55948KX
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55949KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55948PX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55949PX
ASEAN, HTK, INDIA, and PRC models
ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943KT
ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets) 55943LT
ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 55946KT
ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output) 5594XKT

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups#rt=product-guide

Lenovo Financial Services


Lenovo Storage V3700 V2 and V3700 V2 XP 28
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services
that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers
financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize
your purchase power by obtaining the technology you need today, protect against technology
obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance
their entire technology solution. We focus on making it easy to do business with us. Our highly
experienced team of finance professionals operates in a work culture that emphasizes the importance of
providing outstanding customer service. Our systems, processes and flexible policies support our goal of
providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware
and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or
months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex
transactions are serviced properly. As a premier client, you have a dedicated finance specialist who
manages your account through its life, from first invoice through asset return or purchase. This specialist
develops an in-depth understanding of your invoice and payment requirements. For you, this dedication
provides a high-quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider
about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com

Related publications and links


For more information, see the following resources:
Lenovo Storage V3700 V2 product page:
http://www3.lenovo.com/us/en/p/77X2SHD3700
Lenovo Data Center Solution Configurator (DCSC):
http://dcsc.lenovo.com
Lenovo Storage V3700 V2/V5030 Information Center
http://systemx.lenovofiles.com/help/topic/com.lenovo.storage.common.nav.doc/
overview_storage_vseries.html
Lenovo Storage V3700 V2 and V3700 V2 XP Documentation
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-
storage/v3700v2/6535/documentation
Lenovo Storage V3700 V2 and V3700 V2 XP Support:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v3700v2/6535

Related product families


Product families related to this document are the following:
Lenovo Storage
External Storage

Lenovo Storage V3700 V2 and V3700 V2 XP 29


Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your
local Lenovo representative for information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product,
program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any
Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify
the operation of any other product, program, or service. Lenovo may have patents or pending patent applications
covering subject matter described in this document. The furnishing of this document does not give you any license
to these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.


1009 Think Place - Building One
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the
information herein; these changes will be incorporated in new editions of the publication. Lenovo may make
improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time
without notice.

The products described in this document are not intended for use in implantation or other life support applications
where malfunction may result in injury or death to persons. The information contained in this document does not
affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express
or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information
contained in this document was obtained in specific environments and is presented as an illustration. The result
obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply
in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any
manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials
for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was
determined in a controlled environment. Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level systems and there is no guarantee
that these measurements will be the same on generally available systems. Furthermore, some measurements may
have been estimated through extrapolation. Actual results may vary. Users of this document should verify the
applicable data for their specific environment.

© Copyright Lenovo 2019. All rights reserved.

This document, LP0497, was created or updated on September 11, 2018.


Send us your comments in one of the following ways:
Use the online Contact us review form found at:
http://lenovopress.com/LP0497
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at http://lenovopress.com/LP0497.

Lenovo Storage V3700 V2 and V3700 V2 XP 30


Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other
countries, or both. A current list of Lenovo trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
AnyFabric®
Flex System
Lenovo Services
Lenovo®
RackSwitch
System x®
ThinkServer®
ThinkSystem
TopSeller
The following terms are trademarks of other companies:
Linux® is a trademark of Linus Torvalds in the United States, other countries, or both.
Internet Explorer®, Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.

Lenovo Storage V3700 V2 and V3700 V2 XP 31

You might also like