BullSequana S400 and Dell EMC VMAX 250F Fast Track
BullSequana S400 and Dell EMC VMAX 250F Fast Track
BullSequana S400 and Dell EMC VMAX 250F Fast Track
Abstract
September 2018
Revisions
Acknowledgements
Special thanks to Erwan Prevost, Greig Lilienfeld and Ryno Coetzee from Dell EMC, Arnaud
Aumonier, Benoit Gonsolin and Virgil Chetty from ATOS BDS and Jamie Reding and Donovan White
from Microsoft
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 2
Table of Contents
Revisions ................................................................................................................................................. 2
Acknowledgements................................................................................................................................. 2
Executive ................................................................................................................................................. 5
Introduction ............................................................................................................................................ 6
Target audience ...................................................................................................................................... 6
Data warehouse workload challenges .................................................................................................... 7
SQL Server 2017 ...................................................................................................................................... 8
SQL Server Data Warehouse Fast Track .................................................................................................. 9
Recommended reference architectures ............................................................................................... 10
Single server reference architecture ................................................................................................ 10
High available reference architecture............................................................................................... 12
Hardware components ......................................................................................................................... 14
ATOS BullSequana S400 server ......................................................................................................... 14
Emulex LPe31002-M6 16 Gbps Host Bus Adapter ............................................................................ 14
Brocade® 6510 switch ....................................................................................................................... 15
Dell EMC VMAX 250F ........................................................................................................................ 15
Scalable Performance ................................................................................................................... 15
Mission-Critical Availability ........................................................................................................... 15
Hyper Consolidation...................................................................................................................... 16
Storage configuration ........................................................................................................................... 17
Hardware configuration of Dell EMC all flash array.......................................................................... 17
Front and Rear View of the system................................................................................................... 17
Engine Slots and FA Ports Layout...................................................................................................... 18
Logical configuration of the array ..................................................................................................... 18
LUN / Disk configuration and FA port assignments .......................................................................... 19
VMAX storage groups (SG)................................................................................................................ 19
Read and write cache........................................................................................................................ 20
Server connectivity and multi-pathing.............................................................................................. 20
Cabling............................................................................................................................................... 21
Cabling single server configuration................................................................................................... 21
Cabling high available server configuration ...................................................................................... 22
BullSequana S400 server configuration ................................................................................................ 23
System BIOS ...................................................................................................................................... 23
Emulex LPe31002-M6 16 Gbps Host Bus Adapter ............................................................................ 23
Windows Server 2016 configuration .................................................................................................... 25
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 3
Installation ........................................................................................................................................ 25
Drivers and packages installed.......................................................................................................... 26
Power plan ........................................................................................................................................ 26
Lock pages in memory ...................................................................................................................... 27
Windows disks .................................................................................................................................. 27
MPIO ................................................................................................................................................. 29
Windows Defender configuration..................................................................................................... 30
SQL Server 2017 Enterprise Edition Configuration ............................................................................... 31
Grant perform volume maintenance task privilege.......................................................................... 31
Tempdb configuration ...................................................................................................................... 31
Start-up parameters for the SQL Server instance ............................................................................. 31
SQL Server maximum memory ......................................................................................................... 32
Maximum Degree of parallelism (MAXDOP) .................................................................................... 32
Resource governor ............................................................................................................................ 33
Database configuration..................................................................................................................... 33
Additional considerations for the Highly Available (HA) reference architecture ............................. 33
DWFT certification for ATOS BullSequana S400 with Dell EMC VMAX 250F ........................................ 34
Summary ............................................................................................................................................... 35
Technical support and resources Dell EMC .......................................................................................... 36
Bill of Materials (BOM).......................................................................................................................... 37
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 4
ATOS, Dell EMC™ and Microsoft®, in cooperation, provide
Executive summary guidelines and principles to assist customers in designing and
implementing a balanced configuration for Microsoft SQL
Server® data warehouse workloads to achieve out-of-the-box
scalable performance. These certified database reference
architectures enable each of the components in the database
stack to provide optimal throughput to match the database
capabilities of the specific setup.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 5
Today’s enterprise businesses face a constant challenge
Introduction keeping pace with the huge data processing and storage
requirements generated by all aspects of their business. As
they face the daunting task of scaling their DBMS systems to
meet short term as well as long term requirements, one of the
first decisions to be made is whether to scale up (add
additional resources to existing systems), or scale out (add
additional separate systems).
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 6
Organizations use data warehouses to aggregate data
Data warehouse collected from operational systems and elsewhere and
workload challenges prepare data for analysis.
Data growth
As the number of IoT devices increase, the data in data
warehouses is growing exponentially. In this environment, it is
important to use solutions that provide high data compression
without compromising query performance, while reducing
storage and I/O bandwidth. Integrated Machine Learning tools
like Python and R makes it possible to run ML models on data
without moving the data.
Both the ATOS BullSequana S400 and the S800 with the Dell
EMC VMAX are designed to grow with your needs. Soon the
ATOS BullSequana can scale up to 32 CPU’s and the Dell EMC
VMAX 250F can scale up to 1.1 PB and the 950F to 4.4 PB.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 7
Microsoft SQL Server 2017 has made significant improvements
SQL Server 2017 in data warehousing technologies and performance, including
column-store features as well as many other improvements.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 8
The SQL Server Data Warehouse Fast Track (DWFT) program is
SQL Server Data designed to provide customers with standard and proven
Warehouse Fast system architectures optimized for a range of enterprise data
warehousing needs. The goal is to help enterprise customers
Track deploy data warehouse solutions with a recommended
hardware configuration appropriate for the requirements of
the workload with reduced risk, cost, and complexity.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 9
The following subsections describe the two different DWFT
Recommended reference architectures for SQL Server 2017, comprised of ATOS
reference BullSequana S400 servers and Dell EMC VMAX flash arrays.
architectures
Single server reference Figure 1 illustrates the single server reference architecture with
the major elements and Table 1 lists the component details.
architecture
Public network
BullSequana S400
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 10
Table 1 Single server reference architecture
Component Description
Server BullSequana S400
Processors 4x Intel® Xeon Platinum 8180M processors (2.5
MHz, 28 cores and 56 threads)
Total cores 112
Total Logical Processors 224
Total RAM 6 terabytes in 128 GB DIMM’s
Host Bus Adapters 5x Emulex LPe31002-M6 adapter
Network Adapters 4x Intel X722 10 Gbps + 4x Intel X722 SFP+
OS disks 800 GB SSD RAID1
Software Operating system Windows Server 2016 Standard Edition
Database software SQL Server 2017 Enterprise Edition Core version
Storage Array Dell EMC VMAX 250FX WITH 1 VBRCK BASE 2048GB
I/O cards 2 PAIRS OF FIBRE CHANNEL MODULES 8MM 8
PORTS 16G FC
Disk drives 32x VMAX 250 RAID5(7+1) 3840GB
SAN switches 2x Brocade® 6510 with 16Gbps SFPs
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 11
High available reference For database high availability, Windows® failover clustering is
recommended. Using Microsoft clustering services, one
architecture database server is configured as the primary (active) server and
the second server is configured as the secondary (passive)
server. The secondary server should have exactly the same
configuration as the primary server. Since the database is only
active on a single server at any point of time, the performance
of the database on the primary server (active) is comparable to
the single server configuration (discussed earlier).
Public network
Private
network
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 12
Table 2 High available reference architecture
Component Description
Server Two BullSequana S400 in active - passive
Processors 4x Intel® Xeon Platinum 8180M processors (2.5
MHz, 28 cores and 56 threads)
Total cores 112
Total Logical Processors 224
Total RAM 6 terabytes in 128 GB DIMM’s
Host Bus Adapters 5x Emulex LPe31002-M6 adapter
Network Adapters 4x Intel X722 10 Gbps + 4x Intel X722 SFP+
OS disks 800 GB SSD RAID1
Software Operating system Windows Server 2016 Standard Edition
Database software SQL Server 2017 Enterprise Edition Core version
Storage Array 1x Dell EMC VMAX 250FX VBRICK BASE 2048GB
I/O cards 2 PAIRS OF FIBRE CHANNEL MODULES 8MM 8
PORTS 16G FC
Disk drives 32x VMAX 250 RAID5(7+1) 3840GB
SAN switches 2x Brocade® 6510 with 16Gbps SFPs
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 13
Hardware components
The BullSequana S line is also available in a S200 version with 2 CPU’s, a S800 with 8 CPU’s (equally
certified by Microsoft for SQL Server 2017 DWH Fast Track architecture), a S1600 with 16 CPU’s and
a S3200 with 32 CPU’s.
The Emulex Gen 6 FC HBAs with Dynamic Multi-core architecture offer higher performance, lower
latency, enhanced diagnostics and manageability that benefit both 16GFC and 32GFC environments
by applying all ASIC resources to any port that needs it. The Emulex Gen 6 HBAs delivers up to
12,800 MB/s (2 ports 32GFC, or 4 ports 16GFC, full duplex), less than half the latency, and support an
industry-leading 1.6 million IOPS per adapter. The quad-port LPe32004 delivers up to 3.2 million
IOPS per adapter.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 14
Brocade® 6510 switch
The Brocade 6510 switch by Broadcom is a 1U, 48-port, rack-mountable Fibre Channel switch
providing up to 16Gbps of bandwidth per port. This switch enables organizations to simplify IT
infrastructures, improve system performance, maximize the value of virtual server deployments, and
reduce overall storage costs.
The Brocade 6510 Switch has all the capabilities you need to help improve network speed and
efficiency.
16Gbps Fibre Channel performance — about 40 percent higher than 10GbE SANs
Up to 48 ports that deliver 768Gbps aggregate full-duplex throughput
Frame-based trunking at rates up to 128Gbps
Exceptionally low power consumption (14 watts/Gbps)
The Dell EMC VMAX All Flash family can scale beyond the confines of a single system footprint to
deliver scalable performance where needed. It enables hundreds of multi-core Intel CPUs to be
pooled and allocated on-demand to meet the performance requirements for dynamic mixed
workloads. This is achieved though powerful multi-threading and the industry’s first dynamic, user
controlled core allocation so no workload is starved of resources. The core element of Dell EMC
VMAX All Flash family is the V-Brick. Each V-Brick has one engine, two DAEs, and usable capacity
with fully redundant components.
For VMAX 250 Flash Capacity Packs are used to scale up to 1.1 petabytes. The VMAX All Flash scales
by aggregating up to two V-Bricks as a single system with fully shared connectivity, processing, and
capacity resources. Each V-Brick supports up to 48 CPU cores for blazing-fast performance scaling to
a maximum of 96 cores per array.
Scalable Performance
• Leverage advanced multi-core/multi-threading algorithms and a flash-optimized design to meet
strict SLAs for high-demand online transaction processing (OLTP), virtualized applications, and high-
growth Oracle and SQL databases
• Scale out performance and scale up capacity to achieve millions of IOPS, PBs of capacity, and
predictable performance (350-microsecond response time)
Mission-Critical Availability
• Mission-critical availability architecture with advanced fault isolation, robust data integrity
checking and proven non-disruptive hardware and software upgrades
• Six-nines availability for 24x7 operations using SRDF software, the gold standard for multi-site
remote replication and DR
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 15
Hyper Consolidation
• Achieve massive consolidation with support for mixed open, mainframe and file storage on the
same system simplifying management and significantly lowering overall TCO
• Consolidate multiple concurrent workloads and multi-PBs of capacity both on premise and through
tiering to cloud storage.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 16
Storage configuration
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 17
Engine Slots and FA Ports Layout
The following figure explains the director and the ports on the vBrick:
Core distribution:
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 18
LUN / Disk configuration and FA port assignments
All LUNs were configured as THIN LUNs in virtual pool created from 64 flash drives. Data are wide
striped across all flash drives in the vBrick.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 19
Read and write cache
VMAX cache is global. It is dynamically used for reads and writes. The default settings were used for
system write pending limit. No cache partitions were created as there is only single application using
system.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 20
Cabling
The hardware components where connected using the ATOS and Dell EMC best practices.
The upper ports of the Brocade switches are used to connect the ATOS BullSequana S400 server.
Each even port of the Emulex HBA’s was connected to the upper ports on the left of Brocade switch
one and each off port of the Emulex HBA’s was connected to the upper ports on the left of Brocade
switch two. The bottom ports are only used to connect the FC ports of the Dell EMC VMAX.
0 Port 1 0 Port 1
0 Port 1
Lnk Act
Lnk Act
0 Port 1
0 Port 1
Lnk Act
Lnk Act
BullSequana S400
Brocade 6510
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
Brocade 6510
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
#
3
3
3
3
2
2
2
2
1
1
1
1
0
0
0
0
3
3
3
2
2
2
1
1
1
0
0
0
Dell EMC VMAX to Brocade F/C switch 1 ATOS BullSequana S400 to Brocade F/C switch 1
Dell EMC VMAX to Brocade F/C switch 2 ATOS BullSequana S400 to Brocade F/C switch 2
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 21
Cabling high available server configuration
The following diagram explains the cabling between two BullSequana S400 servers in a high
availability configuration and the Dell EMC VMAX 250F. The placement of the HBA’s can be different
based on the placement of the HBA modules.
To keep the diagram with all the connections readable the Brocade switches are presented twice:
first only the left part and then the right part.
Lnk Act
Lnk Act Lnk Act Lnk Act
0 Port 1
0 Port 1 0 Port 1 0 Port 1
Lnk Act
Lnk Act Lnk Act Lnk Act
Brocade 6510
Brocade 6510
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
Brocade 6510
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
Brocade 6510
0 4 1 5 2 6 3 7 8 12 9 13 10 14 11 15 16 20 17 21 18 22 19 23 24 28 25 29 26 30 27 31 32 36 33 37 34 38 35 39 40 44 41 45 42 46 43 47
#
3
3
3
3
2
2
2
2
1
1
1
1
0
0
0
0
3
3
3
2
2
2
1
1
1
0
0
0
Dell EMC VMAX to Brocade F/C switch 1 ATOS BullSequana S800 to Brocade F/C switch 1
Dell EMC VMAX to Brocade F/C switch 2 ATOS BullSequana S800 to Brocade F/C switch 2
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 22
BullSequana S400 server configuration
System BIOS
All options, except for the BMC network configuration, were left at their factory default settings. The
Logical Processor option, under Processor Settings, is left at its default setting of Enabled. This
enables Intel® Hyper-Threading Technology, which maximizes the number of logical processors
available to SQL Server.
If this is not the case the HBA’s firmware need to be upgraded to this version or the latest available
for each HBA. The latest firmware can be downloaded from the Broadcom Emulex site
(https://www.broadcom.com/products/storage/fibre-channel-host-bus-adapters/lpe31002-m6).
The update of the firmware can be performed using the “Download Firmware” button in the Emulex
OneCommand™ Manager. Changing the driver and or the firmware could require a restart of the
server.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 23
Except the QueryDept parameter – which was changed from 32 to 64 – all the other host and HBA
parameters were left at their default settings.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 24
Windows Server 2016 configuration
Installation
The installation of Windows was done with the default settings. After the installation, the Windows
Feature MPIO was activated as shown in figure 8.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 25
Drivers and packages installed
It is important to have the drivers and packages on a USB key because the network adapters are
newer than Windows 2016 and the drivers are not part of the Windows Drivers Catalogue included
on the installation DVD.
After the installation of Windows and the MPIO, the following drivers and packages were installed
(in that order):
After the installation of these drivers and packages, a restart of Windows might be needed.
Power plan
To maximize performance, the server was configured to use the High performance power plan as
shown in Figure 9.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 26
Lock pages in memory
To prevent Windows from paging SQL Server memory to disk, the Lock pages in memory option was
enabled for the SQL Server service account. Remember to restart the SQL Server instance to for this
setting to take effect.
For information on enabling this option, visit Enable the Lock Pages in Memory Option
Windows disks
After the zoning in the switches and the VMAX are done the LUN’s show up in Windows Disk
Management. After putting the disks on-line and the initialisation, all LUN’s are formatted with ReFS
and a block size of 64 KB:
If all the disks are formatted properly, Windows Disk Management shows the following list:
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 27
There are in total, there are 17 LUN’s:
Performing a quick format of an eight terabyte LUN might take some time.
For DWFT reference architectures, ATOS and Dell EMC recommends using mount points for the
volumes instead of drive letters. It is highly recommended to assign appropriate volume and mount
point names in order to simplify troubleshooting and performance analysis. Ideally, the mount point
names should be assigned in a way that makes it easy to identify the VMAX volume for a given
Windows volume.
The following table shows the volume labels and access paths used for the reference configuration:
After completing of all the LUN’s the directory C:\Storage looks like this:
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 28
MPIO
MPIO was configured using Dell EMC best practices. MPIO best practices for the VMAX array are
documented in the paper, Dell EMC Host Connectivity Guide for Windows.
The MPIO policy for all volumes is left at Least Queue Dept, allowing a load balancing policy that
sends I/O down the path with the fewest currently outstanding I/O requests.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 29
Windows Defender configuration
Microsoft Windows Defender is a standard installed anti-virus and anti-spam component. To prevent
the scanner to scan the SQL Server data and log files the following exclusions must be added to
guarantee performance:
Exclude the following folders in a high availability (HA) solution (not displayed):
.ldf
.mdf
.ndf
These settings are also valid for other virus scanners. More information on configuring virus scanners
with SQL Server is available at https://support.microsoft.com/en-us/help/309422/choosing-
antivirus-software-for-computers-that-run-sql-server
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 30
SQL Server 2017 Enterprise Edition Configuration
The installation was done using mostly of the default settings. Some exceptions are listed below.
Tempdb configuration
The tempdb database was configured to use eight data files of equal size. The data files were placed
on the eight tempdb data volumes. The tempdb transaction log file was placed on the log volume.
All files were expanded to the appropriate size and auto grow was enabled.
More information in the Microsoft article, DBCC TRACEON - Trace Flags and Database Engine Service
Start-up Options.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 31
SQL Server maximum memory
The maximum server memory for this reference architecture should be set to 5.767.168 MB or
5.632GB, which leaves 512 GB for the operating system. If additional applications share the server,
adjust the amount of memory left available to the operating system accordingly.
For more information on the MAXDOP see the Microsoft article, Configure the max degree of
parallelism Server Configuration Option.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 32
Resource governor
Depending on the type of workload used the most – row store (RS) or clustered column store (CS) –
the settings of the Resource Governor needs to be adapted accordingly.
For the row store the resource governor setting used to limit the maximum memory grant is set to
12 percent.
For the column store the resource governor setting used to limit the maximum memory grant is set
to 25 percent.
For information about the resource governor, visit the Microsoft page Resource Governor.
Database configuration
The data warehouse database was configured to use multiple file groups, each containing eight files
distributed evenly across the eight data volumes. All files were allowed to grow automatically. The
file groups were configured with the AUTOGROW_ALL_FILES option to help ensure that all files
within a given file group remain the same size.
An additional volume needs to be created and configured as the disk witness. Dell EMC recommends
using a 2GB volume for the disk witness. For more information on quorum and voting configurations
in a failover cluster, see the Microsoft article, Configure and Manage a Quorum.
All volumes need to be mapped to each node of the cluster. All volumes need to be configured as a
cluster resource and added to the SQL Server cluster resource group.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 33
DWFT certification for ATOS BullSequana S400 with Dell EMC
VMAX 250F
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 34
Summary
ATOS and Dell EMC, in partnership with Microsoft, enables customers to deploy tested and validated
data warehouse solutions using Data Warehouse Fast Track reference architectures for SQL Server
2017. These uniquely designed architectures ensure optimal business intelligence solutions. The
end-to-end best practices and recommendations enable the customer to achieve enhanced return
on investment and faster time to value with a balanced data warehouse environment that can
perform better than traditional data warehouse systems.
The ATOS / Dell EMC DWFT reference architectures provide the following benefits:
Deliver a tested and validated configuration with proven methodology and performance
behaviour
Deliver outstanding performance on the ATOS BullSequana S400 server platform with
blazing processor speeds and leading-edge, all-flash-based Dell EMC VMAX 250F storage
arrays
Achieve a balanced and optimized solution at all levels of the stack by following best
practices for both hardware and software components, achieving faster time to value, and
lower total cost of ownership
Avoid over provisioning of hardware resources
Offer high availability at all levels of setup (host, switches, and storage)
Offer a single point of contact and accountability for purchases, services, and support; SQL
Server is available to purchase from Dell EMC worldwide
Help customers avoid the pitfalls of an improperly designed and configured system
Reduce future support costs by limiting solution re-architect efforts due to scalability
challenges
This paper describes a reference architecture using an ATOS BullSequana S400 server with a Dell
EMC VMAX 250F all flash storage array. By implementing Data Warehouse Fast Track for SQL Server
2017 design principles, this configuration achieved a 320TB rating.
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 35
Technical support and resources Dell EMC
Dell support is focused on meeting customer needs with proven services and Dell Tech Center is an
online technical community where IT professionals have access for Dell software, hardware, and
services.
Storage Solutions Technical Documents on Dell Tech Center provide expertise that success on Dell
EMC storage platforms.
Additional resources:
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 36
Bill of Materials (BOM)
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 37
Item Description Qty
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 38
Item Description Qty
458-001-711 VMAX FLASH FX POWERPATH PRODUCT=IC 1
458-002-353 VMAX250 FX FLASH ENCRYPTION PRODUCT=IC 1
458-001-691 APPSYNC STR PK FOR VMAX FX SUITE =CC 210
458-001-516 VMAX FLASH FX SUITE OS 1TB=CC 210
450-001-207 VMAX FLASH FX SUITE ENABLER 1TB=CC 210
SQL Server 2017 DWH Fast Track Certification for ATOS BullSequana S400 and Dell EMC VMAX 250F 39