Compact Pneumatic Cylinder
Compact Pneumatic Cylinder
Compact Pneumatic Cylinder
EUS20-184 A -UK
Series C55
ISO Standard [ISO 21287]
Compact Cylinder
Series C55
ø20, ø25, ø32, ø40, ø50, ø63
How to Order
Without
auto switch C55 B 20 10
With auto switch CD55 B 20 10 M9B S
Built in magnet Number of auto switches
- 2 pcs.
S 1 pc.
Mounting style
n “n” pcs.
Through-hole/Both ends
B tapped common (Standard)
L Foot style Bore size
F Rod side flange style Auto switch
20 20 mm
G Head side flange style - Without auto switch (Built-in magnet cylinder)
25 25 mm
C Single clevis style 32 32 mm ∗ For the applicable auto switch model, refer to the table below.
∗ Auto switches are shipped together, (but not assembled).
40 40 mm
50 50 mm
63 63 mm
Rod end thread
- Rod end female thread
Cylinder stroke (mm) M Rod end male thread
Refer to the next page for standard
and intermediate strokes.
Yes
Reed
1
ISO Standard [ISO 21287] Compact Cylinder Series C55
Specifications
Theoretical
Output OUT IN Manufacture of Intermediate Stroke
Unit: N
Operating pressure (MPa) Dealing with the stroke by the 1 mm interval by using an exclusive body
Bore size Operating Description
with the specified stroke
(mm) direction 0.3 0.5 0.7
Part no. Refer to “How to Order” for the standard model no. (page at left)
IN 71 118 165
20 Stroke range 6 to 149
OUT 94 157 220
Part no.: C55B32-47
IN 113 189 264 Example
25 Makes 47 stroke tube
OUT 147 245 344
IN 181 302 422
32
OUT 241 402 563
Weight
IN 317 528 739
40 Without Auto Swtich Unit: g
OUT 377 628 880
Bore size Cylinder stroke (mm)
IN 495 825 1150 (mm)
50 5 10 15 20 25 30 35 40 45 50 60 80 100 125 150
OUT 589 982 1370
20 111 124 137 150 163 176 189 202 215 228 254 306 357 422 487
IN 841 1400 1960
63 25 152 168 183 199 214 230 246 261 277 292 323 386 448 526 603
OUT 935 1560 2180
32 250 273 295 317 339 362 384 406 428 451 495 584 673 785 896
40 315 339 364 388 412 436 461 485 509 533 582 679 776 897 1018
Mounting Bracket Part No. 50 497 534 570 607 644 681 718 755 791 828 902 1049 1197 1381 1565
63 677 717 757 797 837 877 917 957 997 1037 1117 1277 1437 1638 1838
Bore size Single
(mm)
Foot Flange
clevis With Auto Switch (Built-in magnet) Unit: g
Bore size Cylinder stroke (mm)
20 C55-L020 C55-F020 C55-C020
(mm) 5 10 15 20 25 30 35 40 45 50 60 80 100 125 150
25 C55-L025 C55-F025 C55-C025
20 113 126 139 152 165 178 191 204 216 229 255 307 359 424 489
32 C55-L032 C55-F032 C55-C032
25 154 170 185 201 217 232 248 263 279 294 325 388 450 528 606
40 C55-L040 C55-F040 C55-C040
32 254 277 299 321 343 366 388 410 432 455 499 588 677 788 900
50 C55-L050 C55-F050 C55-C050
40 319 344 368 392 416 441 465 489 513 537 586 683 780 901 1022
63 C55-L063 C55-F063 C55-C063
50 502 539 575 612 649 686 723 760 796 833 907 1054 1202 1386 1570
• Order two foot brackets per cylinder.
• Parts belonging to each bracket are as follows. 63 685 725 765 805 845 885 925 965 1005 1045 1125 1285 1445 1645 1845
Foot, Flange, Single clevis/Body mounting bolt Add each weight of auto switches and mounting brackets when mounting an auto switches.
Refer to pages 14 to 17 for auto switch weight.
2
Series C55
500
300
Stroke 200
Eccentric distance 100
100
ø50
ø63 ø40
1
ø32
10 ø50 ø25
ø40 ø20
ø32
0.1
ø25 10 100 200 300 500 1000
1
0 50 100 150 200
∗ Refer to Model Selection in Best Pneumatics catalogue for details about model selection procedure.
3
ISO Standard [ISO 21287] Compact Cylinder Series C55
Construction
ø20, ø25 With auto switch (Built-in magnet)
i t r !4 !2 y q e !3 o w u !0
!2 r t i !4 y q e !3 o w u !0
!1
Mounting Bolt
5
ISO Standard [ISO 21287] Compact Cylinder Series C55
Dimensions
ø20, ø25
2-M5
Auto switch
Port size
øI
4-øN through
T
øD
M
E
Flat washer
2 x 4-OA ø20
4 pcs.
2 x 4-RA (RB) K
L B + Stroke M
A + Stroke E
ø25
6
Series C55
Dimensions
ø32 to ø63
2-G1/8 Auto switch
Port size
Q F 2 x 4-øOB Z H thread
counterbore RB effective depth C
J
øI
4-øN through
T
øD
M
E
Flat washer
2 x 4-OA
4 pcs.
2 x 4-RA (RB) K
L B + Stroke M
A + Stroke E
7
ISO Standard [ISO 21287] Compact Cylinder Series C55
Mounting Bracket
Foot bracket Flange bracket
Hexagon socket
head cap screw
(accessory) FL
2 x øFD 4 x øFD
M
Hexagon socket
head cap screw
R øD
FX
FZ
M
M/2
LH
2 x øLD
L
LT
LX
FT FY
Y X LZ
M
ø20, ø25 ø32 to ø63 FV
(mm) (mm)
Hexagon Hexagon
Bore size socket Bore size socket
(mm) L LD LH LT LX LZ M R X Y head cap
(mm) DH11 M FD FL FT FV FX FY FZ head cap
screw screw
20 22 7 27 4 22 36 22 8 16 7 M5 20 16 22 6.6 2.8 8 38 55 — 68 M5
25 22 7 29 4 26 40 26 10 16 7 M5 25 16 26 6.6 2.8 8 38 60 — 73 M5
32 24.5 7 33.5 4 32 46 32.5 15 16 7 M6 32 30 32.5 7 5 10 50 64 32 79 M6
40 26 10 38 4 36 52 38 17.5 18 9 M6 40 35 38 9 5 10 55 72 36 90 M6
50 31 10 45 5 45 64 46.5 20 21 9 M8 50 40 46.5 9 6 12 70 90 45 110 M8
63 31 10 50 5 50 74 56.5 22.5 21 9 M8 63 45 56.5 9 6 12 80 100 50 120 M8
øCD hole H9
CZ
M
CX
M CU
CZ CW RR
(mm)
Hexagon
Bore size socket
(mm)
CDH9 CL CU CW CX-0.2
-0.6 CZ M RR head cap
screw
20 8 3 12 20 16 35 22 9 M5
25 8 3 12 20 16 40 26 9 M5
32 10 5.5 12 22 26 45 32.5 9.5 M6
40 12 5.5 15 25 28 51 38 12 M6
50 12 6.5 15 27 32 64 46.5 12 M8
63 16 6.5 20 32 40 74 56.5 16 M8
8
Series C55
Proper Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height
A B W ≈ Hs
∗ Figures in the table below are used as a reference when mounting the auto
switches for stroke end detection. In the case of actually setting the auto
switches, adjust them after confirming their operation. (mm)
Symbol A B W A B W A B W Hs
20 11.5 5.5 3.5(1) 15.5 9.5 -0.5 14.5 8.5 -9.5 22
25 11.5 7.5 5.5(3) 15.5 11.5 1.5 14.5 10.5 -7.5 24
Bore size 32 15 9 7 (4.5) 19 13 3 18 12 -6 27
(mm) 40 16 9 7 (4.5) 20 13 3 19 12 -6 30
50 9.5 15.5 13.5(11.5) 13.5 19.5 9.5 12.5 18.5 0.5 36
63 11.5 17.5 15.5(13.5) 15.5 21.5 11.5 14.5 20.5 2.5 41
The dimension inside ( ) is for D-A93.
A B ≈ Hs
Symbol A B Hs A B Hs
20 11.5 5.5 22 15.5 9.5 24
25 11.5 7.5 24 15.5 11.5 26
Bore size 32 15 9 27 19 13 29
(mm) 40 16 9 30 20 13 32
50 9.5 15.5 36 13.5 19.5 38
63 11.5 17.5 41 15.5 21.5 43
9
ISO Standard [ISO 21287] Compact Cylinder Series C55
The Number of Surfaces and Grooves Where an Auto Switch Can Be Mounted (As Direct Mounting)
The number of the surfaces and grooves where the auto switch can be mounted, by switch type, are shown in the table below.
Operating Range
(mm)
Bore size
Auto switch model
20 25 32 40 50 63
D-M9씲W(V)
5 5.5 6 6 6 6.5
D-M9BAL
D-A9씲(V) 9 9 9 9 9 10.5
D-M9씲(V) 3 3.5 3.5 3.5 3.5 4
∗ The operating ranges are provided as guidelines including hystereses and
are not guaranteed values (assuming approximately ±30% variations).
They may vary significantly with ambient environments.
Besides the models listed in “How to Order,” the following auto switches are applicable.
Refer to Best Pneumatics for detailed specifications.
10
Series C55
Auto switch
• Use a watchmakers’ screwdriver with a handle 5 to 6 mm in diameter when tightening the auto
switch mounting screw.
Tightening torque should be set 0.10 to 0.20 N.m.
11
Series C55
Auto Switch Specifications
Auto Switch Common Specifications
Flexible specification
Note) D-M9쏔(V) series use flexible lead wire as standard.
Choke coil
CD-P12 OUT (+)
Brown
Zener diode
Switch operation
position OUT (–)
Blue
(ON)
Hysteresis Note)
Reed switch: 2 mm or less
Solid state switch: 1 mm or less Dimension
Switch operation
position
(OFF)
Connection
To connect a switch unit to a contact protection box, connect the lead wire
from the side of the contact protection box marked SWITCH to the lead
wire coming out of the switch unit. Keep the switch as close as possible to
the contact protection box, with a lead wire length of no more than 1 meter.
12
Series C55
COM COM
PLC internal circuit PLC internal circuit
2-wire 2-wire
Brown Input Blue Input
Switch Switch
13
Reed Switch: Direct Mounting Style
D-A90(V)/D-A93(V)/D-A96(V)
Auto Switch Specifications
Grommet PLC: Programmable Logic Controller
Electrical entry direction: In-line D-A90/D-A90V (without indicator light)
Auto switch model D-A90/D-A90V
Applicable load IC circuit, Relay, PLC
Load voltage 24 V AC/DC or less 48 V AC/DC or less 100 V AC/DC or less
Maximum load current 50 mA 40 mA 20 mA
Contact protection circuit None
Internal resistance 1 Ω or less (including lead wire length of 3 m)
D-A93/D-A93V/D-A96/D-A96V (with indicator light)
Auto switch model D-A93/D-A93V D-A96/D-A96V
Applicable load Relay, PLC IC circuit
Caution Load voltage 24 VDC 100 VAC 4 to 8 VDC
Operating Precautions Load current range
Fix the switch with appropriate screw and max. load 5 to 40 mA 5 to 20 mA 20 mA
current
installed on the switch body. If using other
screws, switch may be damaged. Contact protection circuit None
Internal voltage D-A93 — 2.4 V or less (to 20 mA)/3 V or less (to 40 mA)
drop 0.8 V or less
D-A93V — 2.7 V or less
Indicator light Red LED lights when ON
Lead wires
Auto Switch Internal Circuit D-A90(V)/D-A93(V) — Oilproof vinyl heavy-duty cord: ø2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m
D-A96(V) — Oilproof vinyl heavy-duty cord: ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue), 0.5 m
D-A90(V) Note 1) Refer to page 12 for reed switch common specifications.
Note 2) Refer to page 12 for lead wire lengths.
Contact OUT (±)
Reed switch
protection Brown
box Weight Unit: g
CD-P11
CD-P12 OUT (±)
Blue
Auto switch model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V
Lead wire length: 0.5 m 6 6 6 6 8 8
D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41
LED diode Brown
Contact OUT (+)
Resistor protection Brown
Dimensions Unit: mm
Reed switch
box
Zener
diode CD-P11
CD-P12 D-A90/D-A93/D-A96
OUT (–) Indicator light
Blue Blue
D-A90 without indicator light
M2.5 x 4 l
Slotted set screw
D-A96(V)
DC (+)
LED diode Brown
(+)
Resistor Most sensitive
Load
Reed switch
Indicator light
D-A90 without indicator light 14
Solid State Switch: Direct Mounting Style
D-M9N(V)/D-M9P(V)/D-M9B(V)
Auto Switch Specifications
Grommet PLC: Programmable Logic Controller
DC (+)
Brown D-M9쏔
Main circuit
of switch
D-M9P(V)
2.7
2.8
4
DC (+)
Brown 22 500 (3000)
Main circuit
of switch
OUT
Black D-M9쏔V
DC (–)
Blue
2.7
D-M9B(V)
2.6
OUT (+)
9.5
Brown
Main circuit
of switch
OUT (–)
Blue
4
2.8
15
2-colour Indication Type, Solid State Switch: Direct Mounting Style
D-F9NW(V)/D-F9PW(V)/D-F9BW(V)
Auto Switch Specifications
Grommet PLC: Programmable Logic Controller
D-F9쏔W/D-F9쏔WV (with indicator light)
Auto switch model D-F9NW D-F9NWV D-F9PW D-F9PWV D-F9BW D-F9BWV
Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular
Wiring type 3-wire 2-wire
Output type NPN PNP –
Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC
Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) –
Current consumption 10 mA or less –
Load voltage 28 VDC or less – 24 VDC (10 to 28 VDC)
Caution Load current 40 mA or less 80 mA or less 5 to 40 mA
Operating Precautions 1.5 V or less
Internal voltage
(0.8 V or less at 10 mA 0.8 V or less 4 V or less
drop
Fix the switch with appropriate screw load current)
installed on the switch body. If using other Leakage current 100 µA or less at 24 VDC 0.8 mA or less
screws, switch may be damaged.
Operating position .......... Red LED lights when ON.
Indicator light
Optimum operating position .......... Green LED lights when ON.
Auto Switch Internal Circuit Lead wires
Oilproof vinyl heavy-duty cord: ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue),
D-F9NW(V) 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m
Note 1) Refer to page 12 for solid state switch common specifications.
DC (+) Note 2) Refer to page 12 for lead wire lengths.
Brown
Main circuit
OUT
of switch
Black
Weight Unit: g
DC (–)
Blue Auto switch model D-F9NW(V) D-F9PW(V) D-F9BW(V)
0.5 7 7 7
Lead wire length
3 34 34 32
(m)
D-F9PW(V) 5 56 56 52
DC (+)
Brown
Main circuit
Dimensions
of switch
Unit: mm
OUT
Black
D-F9첸W
2.6
4
DC (–)
Blue
6 Most sensitive position
2
OUT (+)
Brown
Main circuit
of switch
22
2.8
ø2.7
Blue
4
3.1
Optimum operating
position
20
2.8
4.6
16
Water Resistant 2-colour Indication Type
Solid State Switch: Direct Mounting Style
D-M9BAL
Auto Switch Specifications
Grommet PLC: Programable Logic Controller
D-M9BAL (with indicator light)
Water (coolant) resistant type Auto switch model D-M9BAL
Wiring type 2-wire
Output type —
Applicable load 24 VDC relay, PLC
Power supply voltage —
Current consumption —
Load voltage 24 VDC (10 to 28 VDC)
Load current 5 to 30 mA
Internal voltage drop 5 V or less
Leakage current 1 mA or less at 24 VDC
Caution Indicator light Operating position ..... Red LED lights when ON.
Optimum operating position ..... Green LED lights when ON.
Operating Precautions
Lead wires
1. Please consult with SMC if using coolant Oilproof vinyl heavy-duty cord: ø2.7, 2 cores (Brown, Blue), 0.18 mm2, 0.5 m
liquid other than water based solution. Note 1) Refer to page 12 for solid state switch common specifications.
2. Fix the switch with appropriate screw ins- Note 2) Refer to page 12 for lead wire lengths.
talled on the switch body. If using other
screws, switch may be damaged.
Weight Unit: g
OUT (+)
Brown
Main circuit
Dimensions Unit: mm
of switch
OUT (-)
Blue
17
18
EUROPEAN SUBSIDIARIES:
© DiskArt™ 1988
UK
SMC Industrial Automation CZ s.r.o. SMC Pneumatics (Ireland) Ltd. SMC Romania srl SMC Pneumatics (UK) Ltd
Hudcova 78a, CZ-61200 Brno 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Str Frunzei 29, Sector 2, Bucharest Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN
Phone: +420 5 414 24611, Fax: +420 5 412 18034 Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 Phone: +40 213205111, Fax: +40 213261489 Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064
E-mail: office@smc.cz E-mail: sales@smcpneumatics.ie E-mail: smccadm@canad.ro E-mail: sales@smcpneumatics.co.uk
http://www.smc.cz http://www.smcpneumatics.ie http://www.smcromania.ro http://www.smcpneumatics.co.uk
http://www.smceu.com
http://www.smcworld.com
SMC CORPORATION 1-16-4 Shimbashi, Minato-ku, Tokio 105 JAPAN; Phone:03-3502-2740 Fax:03-3508-2480
Produced and printed by SMC European Marketing Centre 12/04 Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.