Modulo Eminic
Modulo Eminic
Modulo Eminic
2
Table of contents
Airways adapters 9
Gas scavenging 11
3
Water Separation Accessories
D-fend Pro and D-fend Pro+ water traps for single-width CARESCAPE* respiratory modules
M1182629 M1200227
Replace the D-fend Pro water trap every two months Replace the D-fend Pro+ every 24 hours, for each new
or more frequently if the monitor so indicates. patient, or more frequently if the monitor so indicates.
D-fend Pro and D-fend Pro+ water traps are recommended to be used
with the following modules:
D-fend Pro X X
D-fend Pro+ X X
D-fend Pro and D-fend Pro+ water traps are specified for use with the
following modules:
E-sCO, E-sCOV, E-sCAiO, E-sCAiOV, E-sCAiOE, E-sCAiOVE
4
D-fend water traps for double-width compact airway gas modules
876446-HEL 881319-HEL
The GORE-TEX membrane of D-fend water trap inhibits bacteria, viruses, water and mucus from entering the respiratory
measurement system.
There are application-specific water traps for Anesthesia and Critical Care.
Replace the water trap every two months or more Replace the water trap every 24 hours, for each new
frequently if the monitor so indicates. patient, or more frequently if the monitor so indicates.
D-fend and D-fend+ water traps are recommended to be used with the following modules:
D-fend X X X
D-fend+ X X X
D-fend and D-fend+ water traps are specified for use with the following modules:
E-CO, E-COV, E-COVX, E-CAiO, E-CAiOV, E-CAiOVX
In Anesthesia, replace the water trap every two P/N Description Quantity
months or more frequently if the monitor so indicates. 8002174 Mini D-fend 10 / Case
In Critical Care, replace the water trap every 24 hours,
Mini D-fend water trap is specified for use with the following
for each new patient, or more frequently if the monitor
module:
so indicates.
E-miniC
5
Patient Spirometry Accessories
D-lite flow sensors for Patient Spirometry
Ventilator independent, the flow sensor obtains measurement at the patients airway.
Only one connector is needed for lung mechanics, airway gases and metabolism.
Lightweight sensors can be used anywhere GE Healthcare respiratory monitoring technology is applied, including in
anesthesia delivery and ICU ventilation.
FOR HUMID CONDITIONS:
The D-lite+ and Pedi-Lite+ flow sensors’ hydrophilic surface prevents the condensed water from disturbing the measurement.
Measurement range 150 – 2000 ml 150 – 2000 ml 150 – 2000 ml 5 – 300 ml 5 – 300 ml
(Tidal volume) 15 – 300 ml 1 15 – 300 ml 1
6
Patient Spirometry tubes
Spirometry tubes are for single patient use only. P/N Description Quantity
890031 Spirometry Tube, 2 m (7 ft) 5 / Case
Note:
Use 2 m sampling lines with the gas exchange 884101 Spirometry Tube, 3 m (10 ft) 5 / Case
measurement. 891191-HEL Spirometry Tube, 6 m (20 ft) 5 / Case
Note: Use for MRI monitoring
73318-HEL,
73319-HEL, 8004383,
73306 733170
GE Healthcare’s gas sampling lines help ensure accurate P/N Description Quantity
measurements and problem-free use. They are tested and 73318-HEL Gas sampling line, 2 m (7 ft) 10 / Case
validated with GE Healthcare equipment.
733188 Gas sampling line, 2 m (7 ft) 100 / Case
Gas sampling lines with an elbow connector are well-
73319-HEL Gas sampling line, 3 m (10 ft) 10 / Case
suited for use with flow sensors.
733199 Gas sampling line, 3 m (10 ft) 100 / Case
73306 Gas sampling line, 6 m (20 ft) 5 / Case
Anesthesia gas sampling lines are for single patient Note: Use for MRI monitoring
use only.
8004383 Gas sampling line, 2 m (7 ft) 10 / Case
Use PVC/PE gas sampling lines when anesthetic with Elbow Connector
agents are present. Note: Use with D-lite sensors
Use 2 m gas sampling lines with the gas exchange 733170 Gas sampling line, 3 m (10 ft) 10 / Case
measurement. with Elbow Connector
Note: Use with D-lite sensors
Gas sampling lines are specified for use with the following
modules:
E-CO, E-COV, E-COVX, E-CAiO, E-CAiOV, E-CAiOVX, E-sCO,
E-sCOV, E-sCAiO, E-sCAiOV, E-miniC, E-sCAiOE, E-sCAiOVE
73385-HEL 73386-HEL
Airway adapters are for single patient use only. P/N Description Quantity
73385-HEL Straight T-adapter 10 / Case
Dead space:
Straight T-adapter: 7.5 ml 733856 Straight T-adapter 100 / Case
Elbow adapter: 10 ml 73386-HEL Elbow adapter 10 / Case
733866 Elbow adapter 100 / Case
Nasal cannulas are specified for use with the following modules:
E-CO, E-COV, E-COVX, E-CAiO, E-CAiOV, E-CAiOVX, E-sCO, E-sCOV, E-sCAiO, E-sCAiOV,
2070599-001, 2070600-001 E-sCAiOE, E-sCAiOVE, E- miniC
Nasal sampling lines are specified for use with the following modules:
E-CO, E-COV, E-COVX, E-CAiO, E-CAiOV, E-CAiOVX, E-sCO, E-sCOV, E-sCAiO, E-sCAiOV,
878003, 878004, 878005 E- miniC, E-sCAiOE, E-sCAiOVE
10
Gas scavenging
Exhaust lines are specified for use with the following modules:
E-CO, E-COV, E-COVX, E-CAiO, E-CAiOV, E-CAiOVX, E-sCO, E-sCOV, E-sCAiO, E-sCAiOV, E-sCAiOE, E-sCAiOVE
M1031273
P/N Description
M1031273 Adapter for gas return
11
Quick Guide: select the right accessories
Step 1: Select the water trap
D-fend+, Green
Critical Care 881319-HEL
Double-width
compact airway gas module
E-CO (V) (X), E-CAiO (V) (X) D-fend, Black
Anesthesia 876446-HEL
1 Check the tidal volume from the module and the monitor manuals.
12
Calibration gases & regulators
Use the calibration gas recommended for your module, and follow the recommended calibration intervals to ensure that the
measurement accuracy remains within specifications.
Gas exchange in
Anesthesia Critical Care CO2, E-miniC
Critical Care
E-sCO x
E-sCOV x
E-sCAiO x
E-sCAiOV x
E-CO x
E-COV x
E-COVX x
E-CAiO x
E-CAiOV x
E-CAiOVX x
E-miniC x
GE Healthcare GE Healthcare Finland Oy GE Healthcare © 2013 General Electric Company – All rights reserved.
8200 W. Tower Ave. Kuortaneenkatu 2 3/F Building # 1, General Electric Company reserves the right to make
changes in specifications and features shown herein, or
Milwaukee, WI 53223 00510 Helsinki GE Technology Park discontinue the product described at any time without
notice or obligation. Contact your GE Representative for
U.S.A. Finland 1 Hua Tuo Road the most current information.
Shanghai 201203 * GE, GE Monogram, Aespire, Avance and CARESCAPE are
www.gehealthcare.com China trademarks of General Electric Company.