Design of Wall A
Design of Wall A
Design of Wall A
Diameter of reinforcement = 16 mm
Effective depth of wall, d = 242 mm
K = Mu/(Fcu x b x d^2)
Ast = Mu/0.95.fy.z
= 24.955 x 10^6 / (0.95 x 460 x 229.900)
= 248.392 sq.mm
Diameter of reinforcement = 16 mm
Effective depth of wall, d = 226 mm
Ast = Mu/0.95.fy.z
= 22.957 x 10^6 / (0.95 x 460 x 214.700)
= 244.682 sq.mm
Hence no additional shear check or shear reinforcements are required as per clause 3.7.7.4 of BS 8110
D. Check of Deflection
M/bd2 = 24.955x10^6/(1000x242²)
= 0.426
Service Stress, fs = 2/3 x fy x As req/As prov (From Equation 8, BS 8110: Part 1)
= 74.677 N/mm2
Modification factor, MF = 3.078 (From Equation 7, BS 8110: Part 1)
= 2 ,as the value is greater than 2
Support condition = Simply Supported
Span / Eff. Depth ratio = 20 (From Table 3.9, BS 8110: Part 1)
Span of the wall = 6500 mm
Depth required for deflection = 6500/(20x2) (Considering the shorter span)
= 163 mm
> 242 mm Hence OK
Dia of bar Ф = 16 mm
Spacing of bar = 200 mm
Area of bar = 201.0619 mm2
Area of steel per meter length As = 1005 mm2
Area of concrete Ac = 150000 mm2