COMMISIONING
• For doing so, X84 in UBA2 must be disconnected and lift in normal from the control cabinet.
4.0.2. Cabin roof “in level” with door sill in lift with encoder positioning:
If we want to do like this, we must activate/deactivate 3 times landing door lock (at any floor except bottom one) and press
landing call After acting about landing door lock, LOP will make bip signal in that moment we must press that landing call,
and the lift will move down in slow speed and leave the car roof “in level” with that door sill. If after 20 seconds we did not
change to Insepction, lift will return to nomral mode.
POME/DiagPC/DiagPDA Write in address position AE39=A5, controller will change to 00 or 01 depending on the new
direction; if the process is faulty it will show FF. Activate recall for saving changes.
CMB/CMS
FI
4.1.1. Electrical/mechanical components revision: Checking the installation without power supply
• Right functioning of electrical/mechanical components all of them are making right contact.
4.1.2. Insolation of the shaft installation ohm resistance between UBA2 0V and installation earth is zero ohms; J50 must
be placed
4.1.3. Phases Voltages L1, L2 and L3 are according to the specifications with +10% and -15%
• Voltage in board input voltage: it must be taken with the connector unplugged from the board; it must follow the order
of the next table 1.
output voltage: it must be taken with the connector plugged to the board; it must follow the order of
the next table 2.
Table 1 Table 2
TENSIÓN in Connector Board TENSIÓN in Connector Board
230 Vac X133.3 (PE), X133.2 (N), X133.1 (L1) UBA2 230Vac X130.1 y X816.1 (N), X130.2 y X816.3 (L1), X816.2 (PE) UBA2
24 Vdc X302.1(+), X302.2(-) UCC2 24 Vdc X604.1 o X604T.1(+), X604.2 o X604T.2(-) UCP+
24 Vdc X602.1(+), X602.2(-) UCP+ X813, X814 (Brake power supply) UBV
4.1.6. Automatic rescue for lack of power supply: UPS parameter 32E4 must be
01. Only in HD lifts must be 03
4.1.7. Brake tests: Lift must be in normal, top/bottom level and Static & dinamic
must be done in sequence.
• Static turning –S72 right or left (I or II position) and keeping so for more
than 4 seconds, one brake (I or II) will be opened; we can see it by LEDs SF1
and SF2, Off=open and On= close. Repeat the same for the other brake.
• Dinamic After making both static tests; turning –S72 (into position I or II),
hold –S72 in that position and giving order to move from the UBA2 board; then
lift will start to move and when it reachs nominal speed it will activate one
break and lift will be stopped; then realease –S72, send the lift to the floor
where it started (by pressing up/down push button in the UBA2 or by –S154.1.
Repeat the test for the other brake.
Always to disconnect the power supply and check jumpers in the new board are in the same place.
Leave the controller in rappel or switch lift off. Then we can start to upgrade the FW into CMC4+ boards.
The only FW which is uploaded through the big red connector is the UCM2 (USB2CMC4 or TKE-USB).
The rest of the CMC4+ board should be upgraded through the small red connector of TKE-USB or the
group USB2CMC4+special adapter.
Before reaching job site: LCA1 must be activated and take it with you for commisioning +
POME/BOMO/DiagPC/DiagPDA/LD2T,
At job site:
• Shaft teaching
• Load weight device tare
If we want to know the % of load inside the car controller must be in rappel; then activate and deactivate
SW3 in the UCM2 and car display will show % of cabin nominal load,
With one load weight cell in traction ropes Tare must be carried out in 2 steps. First tare at the bottom flor
and second one at the top floor.
Shaft teaching: if lift has encoder positioning. LIFT IN NORMAL in bottom floor (FI on and CMB OFF).
When the lift has made a complete travel of the shaft: AE53 or F4 will show «00»: Teach-in correctly
done or «FF» fault during the process.
For working with this option, calibration with two point of load is needed. And activate P8,18 in Vacon VVVF.
Lift in recall
*3 to 00; in this moment controller is waiting for ‘0’ car call, so we must activate ‘0’ cabin push button;
then display will change to 01 and we’ll press ‘1’ cabin push button;
…
if display shows 40, we’ll press open push button in COP. Ckeck table 3
Whenever we have finished with push buttons, we’ll press the last one pressed as many time as
needed to get *3 on the display again.
October 2014
0…31 level 0 to 31
42 Ccanelling calls
43 cabin priority
44 authorized persons
45 firemen indicator
46 overload
47 buzzer
48 VIP/Shabbat/Attika indicator
49 lift man
technicalservice.tkems@thyssenkrupp.com
51 lift man down direction
52 lift man starting
4.2.1. COMMISIONING:Configurating push buttons
53 lift man 80%
ThyssenKrupp 54 lift man call downwards
55 lift man upwards
the COP and press directly into the BMC.
If it’s an output configuration we must open
56 firemen key
Elevator Manufacturing Spain
57 fan key
58 Shabbat key
59 light key
Acceso trasero 1
71 keypad 2
72 keypad 3 Acceso frontal 2
Failure due to short-circuit of one of the protected ucm2 outputs (further details in “fault
43 2Bh NO FALLO_PROTEC_SALIDAS NO
subcodes”).
44 2Ch No POWER_FAIL No Power failure
45 2Dh No FALLO_24V No 24V failure
46 2Eh No STS_SHABBAT No Control in SHABBAT mode
47 2Fh No FALLO_EQUIPO_EMERG *8 Emergency equipment in car (EAR) failure signal
48 30h YES ERROR_CONTAJE *6 Vane counting fault (Shaft copying)
49 31h YES OVER_CONEX *0 Number of connections/time exceeded
50 32h YES NO_CIERRA_41 *7 There is no LOCK signal on attempting to close the door
51 33h YES NO_CIERRA_40 *7 There is no presence signal on attempting to close the door
52 34h YES OVERT_DOOR *7 The number of “close_attempts” (attempts to close the doors) was exceeded
Landing door opened w/o voltage in main controller; reset activating and
76 4Ch YES APER_PTA_V0 *3
deactivating the emergency switch on the control board
77 4Dh NO CORTO_UCC NO Short-circuit in Car board UCC2. It may also trip due to overconsumption
78 4Eh YES APER_PTA_V1 *3 Landing door opened with voltage in main controller
Failure during teach-in, no rear landing plate detected (further details IN “FAULTS
85 55h YES NO_UCPS_TRASERO *A
SUBCODES”)
Failure during teach-in, no front landing plate detected (further details in “fault
86 56h YES NO_UCPS_FRONTAL *B
subcodes”)
87 57h YES MAS_UCPS_FRONTAL *A Teach-in failure, more landing boards than programmed are detected (front)
88 58h YES MAS_UCPS_TRASERO *B Teach-in failure, more landing boards than programmed are detected (rear)
97 61h YES NO_CAE_CPIK0612 *1 None of the running contactors K06, K061 or K062 switch off. (CPI-CAN)
98 62h YES NO_ENTRA_CPIK0612 *1 None of the running contactors K06, K1 or K2 switch on. (CPI-CAN)
99 63h YES NO_CAE_CPIK0F *1 Brake contactor K0F does not switch off. (CPI-CAN)
100 64h YES NO_ENTRA_CPIK0F *1 Brake contactor K0F does not switch on. (CPI-CAN)
101 65h YES FALLO_CANCPI *1 Can communication failure between control and drive
102 66h YES FALLO_SECCPI *1 CPI Starting, stopping or slowdown sequence failure. (CPI-CAN)
103 67h YES FALLO_HNDCHKM16R8 *1 Communication failure between UCM2 and UCV
104 68h YES NO_ENTRA_BRK1 *1 Supervision of brake contacts, BRK1 (can drive) contact is not actuated
105 69h YES NO_CAE_BRK1 *1 Supervision of brake contacts, brk1 (can drive) is not activated
106 6Ah YES NO_ENTRA_BRK2 *1 Supervision of brake contacts, brk2 (can drive) contact is not activated
108 6Ch YES FALLO_INITCPI *1 Initialisation failure between control and drive
109 6Dh NO SHAFT_FUME_SENSOR_ON NO Smoke detector in shaft activated
110 6Eh YES FALLO_CMI_A3 *3 Fault of unintended movement control system
111 6Fh YES INCOHERENCIA_CONTAJE *8 B322 or b232 bi-stable end failure
112 70h NO INUNDACION_SENSOR_ON no Buoy flooding sensor activated
113 71h YES ERROR_PARAM_CMI_A3 *3 Error in parameter ControlMI_A3
114 72h YES NIVEL_BAJO_ACEITE *0 It has been detected that a hydraulic elevator has low oil level
118 76h YES BLOQUEO_A3_FUERA_SR *3 An uncontrolled exit from the area is detected
119 77h Yes FALLO_CORRECCION *3 The start correction sequence could not be initiated.
120 78h Yes BLOQUEO_MSW__FRENO *1 Blocked due to brake microswitch failure.
121 79h yes BLOQUEO_SR *3 Blocked due to sr pre-opening module failure.
7Ah..
122…125 LIBRES
7Dh
126 7Eh YES NO_TMAXNUDGE *9 “tmaxNudge” parameter programmed nudging time out of range.
127 7Fh YES NO_PLT_CORTAS *9 “PltCortas” parameter area with short floors incorrectly defined.
128 80h YES INMEDIATE_STOP *0 Immediate stop, uba2 X90.2 input deactivated
129 81h YES NO_IMPULSOS_PANT *8 No VANE impulses received
130 82h YES EXCESO_PEQUEÑA *8 Programmed time in slow exceeded
131 83h YES NO_ENTRA_HCONT *1 Fast speed contactor does not switch on
132 84h YES NO_CAE_HCONT *1 Fast speed contactor does not switch off
133 85h YES NO_ENTRA_LCONT *1 Slow speed contactor does not switch on
134 86h YES NO_CAE_LCONT *1 Slow speed contactor does not switch off
135 87h YES NO_ENTRA_UCONT *1 Upwards trip contactor does not switch on
148 94h YES NO_MAXT_DOOR *9 “maxt_door” parameter maximum door time out of range.
149 95h YES NO_CONEX_HORA *9 “conex_hora” parameter maximum number of connections/hour out of range.
150 96h YES NO_RESERVA_CONEX *9 “reserva_conex” maximum connection reserve out of range.
151 97h YES NO_MAXT_GRANDE *9 “maxt_grande” parameter maximum fast speed time out of range.
152 98h YES NO_MAXT_PEQUEÑA *9 “maxt_pequena” parameter maximum slow speed time out of range.
153 99h YES NO_MAXT_RENIVEL *9 “maxt_renivel” parameter maximum re-levelling time out of range.
“cab_call_max” parameter maximum permitted number of car calls out of range and if
154 9Ah YES NO_CAB_CALL_MAX *9
greater than the difference between “cota_sup” and “cota_inf”.
155 9Bh YES NO_RET_STOP *9 “ret_stop” parameter maximum stop delay out of range.
156 9Ch YES NO_TIEMPO_ET *9 “time_et” parameter maximum star-delta start switch out of range.
157 9Dh YES PULS_STUCK *9 Button stuck (further details in “fault subcodes”).
“prefer_sup” parameter upper preferential level number out of range of the “cota_sup”
159 9Fh YES NO_PREFER_SUB *9
or “cota_inf” defined in the installation.
“lobby_1” parameter main level 1 number out of range of the “cota_sup” or “cota_inf”
161 A1h YES NO_LOBBY_1 *9
defined in the installation.
“lobby_2” main level 2 number out of range of the “cota_sup” or “cota_inf” defined in
162 A2h YES NO_LOBBY_2 *9
the installation.
168 A8h Yes CODE_FOT_F1 *8 Photo switch position sensor pulse fault (additional info )
169 A9h Yes CODE_FOT_F2 *8 Photo switch position sensor pulse fault (additional info )
170 AAh Yes CODE_FOT_F3 *8 Photo switch position sensor pulse fault (additional info )
171 ABh yes START_SIN_DIRECCION *8 Starting command without setting the direction of travel
175 AFh YES RESCATE_ERROR *3 Dea rescue control error (further details in “fault subcodes”).
178 B2h YES NO_COTAINTERSUP *9 “cota_supInterm” upper intermediate level out of range.
181 B5h YES PARAM_ENCODER *9 Error in a parameter related to the positioning with encoder
186 BAh YES FALLO_CM_SUPLEMENTARIO *9 The extra CM is not consistent with B322 “CMB” and B323 “CMS”
187 BBh NO FALLO_DMC *F The DMC device is not connected or has not been initialised properly
The uco device or can door operator is not connected or was not correctly initialised
188 BCh Yes FALLO_OP *F
(further details in “fault subcodes”).
189 BDh yes FALLO_BTN_LIN *F Failure of one of the car operating panel plates (BMC/IMC).
190 BEh YES FALLO_SECUENCIA_VACONCAN *1 When stopping the Inverter does not authorise brake activation
191 BFh YES FALLO_SCNA_VACONCAN *1 Failure to detect when stopping the opening of the series which is normally open
192 C0h YES FALLO_ESP_VACONCAN *1 When stopping the Inverter does not authorise the opening of the motor contactor
193 C1h YES FALLO_SCNC_BRAKE_VACONCAN *1 Failure to close when stopping the series normally closed
At start-up the series which are normally open and the series normally closed are not in
194 C2h YES FALLO_SCNCNA0_VACON_CAN *1
their initial status
195 C3h YES FALLO_SCNCNA_VACON_CAN *1 At start-up the series which are normally closed fail to open
196 C4h YES FALLO_SECUANCIA_ESP_VACONCAN *1 At start-up the Inverter does not authorise the activation of the motor contactor
201 C9h YES ERROR_TEST_DE_FRENO *1 The brake test concluded incorrectly (further details in “fault subcodes”).
202 CAh YES FALLO_INTENSIDAD_VARIADOR *1 Unexpected current detected in the inverter transformer
203 CBh YES AVERIA_VARIADOR *1 The drive reported a failure (further details in “fault subcodes”).
204 CCh yes AVERIA_VARIADOR_ERROR *1 If a failure occurs in the drive during initialisation thereof.
206 CEh Yes FALLO_SECUENCIA_APERTURA_SERIE_ARRANQUE *1 If the safety series are activated during start.
251 FB NO RST_PILA_AVERIAS NO Fault pile reset or deleted. marks the last time the fault pile was deleted.
Notes:
1. When a short-circuit occurs it may be detected at more than one output in addition to
that which generated it.
2. The drive fault code is calculated using the following formula: vacon fault code =
position + (32, in downward direction) + (64, in upward direction) + (128, if in motion).
3. Brake a indicates first shoe tested and brake b indicates second shoe tested.
ThyssenKrupp
CMC4+ new generation Elevator Manufacturing Spain
October 2014
102 Technical Service – CSC NI ThyssenKrupp
technicalservice.tkems@thyssenkrupp.com Elevator Manufacturing Spain