Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

44523-RWO-Veolia-OWS COM 8 2016 WEB PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

OWS-COM

Oily Water Separator

Complying with your


challenges fulfilling the
5 ppm standard

WATER TECHNOLOGIES
RWO’s reliably reaches
> type
approved
classic: 5 ppm acc. to MEPC.107(49)

limit
by DGUV

Oily Water confirmed by


> confirmed by
USCG, LR, MED, RMRS,

Separators
DNV GL and LR ABS, BV, CCS

More than 14,000 ships have already been


Automatic bypass
equipped with RWO’s oily water separators
since RWO started its business in 1975. To extend the operating life of the demulsi-
The OWS-COM system uses a combination fier, an automatic bypass is fitted to the
of highly effective open porous coalescer separating system. The oil content monitor
with automatic backflushing, together with periodically checks the water quality of the
a second stage emulsion breaking oil and first stage separator. If below the set max.
hydrocarbon polisher. value, the demulsifier is bypassed. This re-
The periodical backflushing keeps the coales- sults in lower operational cost and long
cer surface clean and offers long lasting product life.
operation according to IMO Resolution
MEPC.107(49). The OWS-COM is part of
RWO’s leading Total Water Management
offer.
Your key benefits
> Most economical: second
stage is bypassed whenever
possible
> Easy to install and maintain
> Safest: Oil Monitoring device
always checks effluent
> Suction type: preserves pump
from attrition
> Most compact:
suitable for newbuilds and
retrofit
> Improved hydrodynamics for
longer polisher lifetime

WATER TECHNOLOGIES
Oil content monitor
The RWO oily water separating system is According to IMO Resolution
equipped with a 15 ppm oil content alarm de- MEPC.107(49) an extra 3-way
vice, type tested and approved in accordance valve is installed downstream
with IMO Resolution MEPC.107(49). of the oily water separator in
During flushing of the alarm device the 3-way the overboard line to recirculate the water
diverting valve is in recirculation mode (auto- to the bilge whenever required during Port
matic stopping device). State Control.

55A

2 Power supply
55B
3 Control box
23B 17
4 Oil discharge
25B
42 5 Backwashing outlet
3
A

14
9 Sensor electrode
2 47
10 Electrical heating

14 Mono pump

15 Backwashing inlet

22 25A 15 17 Oil Monitor OMD


For information only.
22 Bilge water inlet
9 10
23B To the bilgewater tank

25A Sample water inlet

25B Flushing water inlet


5
42 Sample tap
C

4
47 Adsorber

55A To overboard

55B To the bilgewater tank


B

Technical Data OWS-COM


Type Capacity A B C Power (kW)
Empty weight
(m3/h) (mm) (mm) (mm) (kg)

0.1 0.1 1100 715 650 0.8 125

0.25 0.25 1005 960 750 2.6 180

0.5 0.5 1050 970 750 3.2 195

1.0 1.0 1220 1170 800 3.2 270

2.5 2.5 1485 1510 1060 3.7 457

5.0 5.0 1715 1825 1385 4.6 757

10.0 10.0 2000 2155 1575 5.7 1195

– Data are subject to change without further notice –

WATER
WATERTECHNOLOGIES
TECHNOLOGIES
Printed on 100 % recycled paper
Resourcing the world

Resourcing the world

SALES
de-vwst.sales.rwo@veolia.com

SPARES
de-vwst.spares.rwo@veolia.com

SERVICE
service.rwo@veolia.com
Veolia Water Technologies Deutschland GmbH · 9.2016

Veolia Water Technologies Deutschland GmbH


Gerold-Janssen-Str. 2 • 28359 Bremen/Germany
Phone: +49 421 53 705-0 • Fax: +49 421 53 705-440
Veoliawatertech.bremen@veolia.com • www.rwo.de