Auditorium B.O.Q All Complete PDF
Auditorium B.O.Q All Complete PDF
Auditorium B.O.Q All Complete PDF
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
2 Flooring work
2.1 Providing & Fixing Carpet underlay with 10mm thick DURAfill or
apporved equivalent of approved Color, manufactured by The Supreme
Industries Limited, or approved equivalent thickness built up using
minimum 10 MM specifically extruded high performance sheet, minimum
density 30 kg / Cu. Mt & compression strength of 0.21 Kg / Cm. Sq.,
when tested as per ASTM D-3575. DURAFIL or appproved equivalent
will work as a moisture barrier & provide cushioning to carpet.
441.17 sqm
2.2 Textile floor carpet over seating area : Providing of Forbo Flotex
Flocked floor covering of 4.3mm thickness rolls having a density of 70
million fibres of nylon 6.6 per M2 , Fire Test EN-13501, Appearence
Retention Hexapod ISO 140-8,Friction Slip Resistance Test EN 14041
Class DS, sanitized anti-microbial treatment with resilient waterproof
backing ,anti allergic cetrtified by British allergy foundation, anti static,
acoustical impact sound should be 20dB and approximate weight of 1.8
k.g./sqm of roll form. The reaction to fire should be as per EN13501-1:
Bfl-s1. carpet should be installed after self leveling compound done
properly as per company specifications. 441.17 sqm
The access floor shall be factory finished with Anti-static High Pressure
laminate with Non Warp technology upto 1mm thickness for superior
adhesion and Surface flatness within 0.75mm.The panel is to withstand
a Concentrated Load of 363 kgs applied on area 25mm x 25mm without
collapse in the centre of the panel which is placed on four steel blocks.
The panel will withstand and Uniformly Distributed Load (UDL) minimum
1250 kg/sqm and an impact load of 50kg all complete as per the
approved manufacturers specification and as per the direction of
Engineer-in-charge. All specification must be printed on the side of the
panel to ensure the quality of the product.
2.5 Supply and installation of vinyl sheet flooring, 2 metre wide and overall
thickness of 2mm. The thickness of wear layer would be 2mm. The
product should be homogeneous and single layered. The wear surface
shall consist of impregnated polyurethane homogeneous mixture of PVC
with TRUESHIELD technology, Plasticizers without DOP, Urethane,
color pigments and filler calendered to form a sheet. Color and pattern
details shall be dispersed throughout the thickness of the wear layer. It
shall conform to group "T" wear resistance as per EN 649, Clean Room
certified with class 'A' as per ASTMF5100, Flammability resistance of
class Bfl-s1 as per GB8624-2006, Dynamic coefficient of friction of class
DS as per EN 13893, Thermal Resistance of 0.072m2K/W as per EN
12667, Thermal conductivity of 0.071W/mK as per EN12524, impact
sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9
as per DIN 51130, Residual indentation of 0.03mm as per GB/T 4085-
2005, Color fastness rating of ≥6 as per ISO 105-B02, total weight being
2.8kg/m2 as per EN430. The product shall be suitable for applications in
class 23/34/43 areas as per EN685. Product shall exhibit antistatic
behaviour, resistance to bacteria,resistance to chemical, resistance to
staining,suitability to castor chair.
Installation- It is important to ensure the subfloor on which the sheet is
being laid is smooth, flat, hard and free from moisture, grease etc. In
case of uneven subfloor the same should be levelled using self leveling
compound. IPS/Vitrified/ceramic/mosaic tiles do not provide zero leveled
sub floor. The moisture present in the subfloor should be less than 8%
before installation of the floor. The sheet should be installed as per
recommended adhesive. The installation shall be undertaken as per
153.00 Sqm
manufacturers installation instructions.
(BILL OF QUANTITY)
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size
600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having
galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation
area with 1.8 mm dia holes and having NRC of 0.5, electro statically
polyester powder coated of thickness 60 microns (minimum), including
factory painted after bending and perforation. 531.41 Sqm
3.3
Board Ceiling for Band/Border Providing & fixing false ceiling at all
height including providing & fixing offramework made of special section,
power pressed from M.S. sheets and galvanised with zinc coating of 120
gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle
cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm,
at 1200mm c/c, one flange fixed to the ceiling with dash fastener
12.5mm dia x 50mm long with 6mm dia bolts,other flange of cleat fixed to
the angle hangers of 25 x10 x0.50mm of
(BILL OF QUANTITY)
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing &
finishing to a flush finish of tapered and square edges of the board with
recommended jointing compounds, jointing tapes,finishing with jointing
compounds in three layers covering up to 150mm on both sides of joints
and two coats of primer suitable for boards, all as per manufacture’s
specification and also including the cost of making opening for light
fittings,grills, diffusers, cut outs made with frame of perimeter channels
suitablyfixed, all complete as per drawings, specificaton and direction of
the Engineer in charge but excluding the cost of painting with:
5 MISCELLANEOUS WORK
5.1 Providing & fixing 6mm thick Wood polymer Composite Board(WPC)
(minimum 625 grams per square metre) of Alstone Oligo make or
approved equivalent and shade on existing pre-prepared wall surface
suitable for direct installation with Alstone stixall adhesive or approved
equivalent as per manufacturer's specifications as per approved drawing
complete in all respects and to the entire satisfaction of the Engineer-in-
charge/ consultant / architect. 122.00 sqm
(BILL OF QUANTITY)
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
5.3
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand and
manufacture, including applying additional coats wherever required, to
achieve even shade and colour. 2453.89 sqm
5.4 Painting with synthetic enamel paint, having VOC (Volatile Organic
Compound) content less than 150 grams/ litre, of approved brand and
manufacture, including applying additional coats wherever required to
achieve even shade and colour.
Two coats 500.00 sqm
5.5 Applying priming coats with primer of approved brand and manufacture,
having low VOC (Volatile Organic Compound ) content.
With ready mixed red oxide zinc chromatic on steel / iron works having
VOC content less than 250 grams/ litre 500.00 sqm
5.8 Providing and fixing factory made precast RCC perforated drain covers,
having concrete of strength not less than M-25, of size 1000 x 450x50
mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross
sectional T.M.T. hoop bars, including providing 50 mm dia perforations
@ 100 to 125 mm c/c, including providing edge binding with M.S. flats of
size 50 mm mm x 1.6 mm complete, all as per direction of Engineer-in-
charge. 158.00 Each
5.9 Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand) 3.99 cum
5.10 15 mm cement plaster on the rough side of single or half brick wall of
mix:
1:4 (1 cement : 4 fine sand) 17.36 sqm
5.11 Providing and laying cement concrete in retaining walls, return walls,
walls (any thickness) including attached pilasters, columns, piers,
abutments, pillars, posts, struts, buttresses, string or lacing
courses,parapets, coping, bed blocks, anchor blocks, plain window sills,
fillets, sunken floor, etc. up to floor five level, excluding the cost of
centering, shuttering and finishing :
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) 61.00 cum
(BILL OF QUANTITY)
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
5.13 Structural steel work in single section, fixed with or without connecting
plate, including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer all complete. 2000.00 kg
5.14 Steel work welded in built up sections / framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
a) In stringers, treads, landings etc. of stair cases, including use of
chequered plate wherever required, all complete 5000.00 Kg
b) In gratings, frames, guard bar, ladder, railings, brackets, gates and
similar works 3000.00 Kg
Note:- Shop drawing for working platform in Auditorium to be
submitted by contractor and work shall be strated only after the
approval of Engineer in charge/IUAC.
5.15 Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733
and IS: 1285, fixing with dash fasteners of required dia and size,
including necessary filling up the gaps at junctions, i.e. at top, bottom
and sides with required EPDM rubber/ neoprene gasket etc. Aluminium
sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-
charge. (Glazing, paneling and dash fasteners to be paid for separately)
:
For fixed portion
(BILL OF QUANTITY)
Name Of Work:- Interior Designing Work of Auditorium including balance Civil Work, Acoustical, Internal electrical and Fire fighting Works at IUAC Campus, New DELHI
6.5 Artwork in interior wall of IUAC auditorium building with Acrylic Paints
complete as per the satisfaction of Engineer-in-charge/IUAC. 25.00 Sqm
7.2
Providing and placing 2 seater sofa Indo make Model: Ceylon or
approved equivalent make. Sofa frame shall be made up of hard wood
and i/c stainless steel spring of 200 mm high in seat jointed with plastic
nivar covered with high quality leatherite The foam shall be made of
polyurethane having density of 40- 45 kg/cubic meter. The rate of high
quality Leatherite used shall be approx Rs. 300/ sq mt. A SPECIAL
TYPE OF UPHOLSTERY IS USED IN THIS SOFA is Microfibre with
Polyester Laminate. IT IS A FABRIC WHICH GIVES A LEATHER FEEL
AND SMOOTH SURFACE. THE FABRIC IS MICROFIBRE WITH
POLYSTER LAMINATED BASE. Slab stock and bonded foam at seat
with recron padding at seat. Backrest is made of slab stock with recron
fillers. Double webbing : Spring and nylon. FRAME MATERIAL: Klin
dried Wood Frame. Seat Foam : Slab stock foam with recron layer. Also
bonded foam used as a supporting material beneath slab stock. Foam
Density : 34 kg/ cubic m. Back Foam : Slab stock foam with recron fill at
back and arms Foam Density : 34 kg/cubic m. Webbing Material : S-
spring along with nylon strips. same expect spring in back covered with
2mm thick PU foam on back side and MS chrome legs . etc the product
should be from BIFMA and FSC Certified Company, complete as per
image/drawing specification under the guidance of Engineer-in-Charge. 6.00 Each
7.4 Supplying and placing in position 21 Seater conference table of Indo Model Z-
Line Flexi or approved equivalent make manufacturing as per design, modular
conference table of size of height 750mm, the top of the table shall be made up
of 36mm thick MDF PVC foiled top with decorative anodized sections with
curved shapde pvc foiled leg with 100mm thickness at centre. The modesty
panel of the table shall be 600mm height made of 18mm thick pre-laminated
particle board. The top, legs and modesty panel shall be joined to each other and
with wire managers shall be provided on table top with 62mm dia to hold wires
the product should be from BIFMA and FSC Certified Company, complete as
per image specification under the guidance of Engineer-in-Charge.
7.5 Providing and placing in position Medium back revolving Chair of Indo make
Model: IML 1018 or approved equivalent make. Chair seat & back made up of
hi-quility leatherite made up of 1.2+/-0.1cm thick hot press plywood measured.
Chair upholstered with leatherite and moulded foam. The foam is desinged with
contoured lumber support for extra confort. The seat and back are arrested
together. The P.U. armrest is made of Nylone Chrome and armrest top
upholstered with leatherite. The front pivot synchro tilt mechanism is designed
with features like 360 degree Revolving type, Chair has gas lift mechanism for
height adjustment resting on MS chrome base dia 60-61 cm with superior
quality five castor wheel pronged with steel strip twin castor wheels and Centre
tilt mechanism etc. the product should be from BIFMA and FSC Certified
Company, complete as per image specification under the guidance of Engineer-
in-Charge.
21 Each
7.6 Providing & Placing Reception Counter in 'U' Shape as per drawing with Main
Desk of size - 6600(L) x 750(D) x 1100(ht) with Side Desk on both sides of size
- 2400(L) x 750(D) x 1100(ht). 19mm thick commercial block board with 1mm
thick decorative Laminate as per approved shade on all exposed surfaces of
board. The unit will be having 3 Pedestal of size 400(W) x 450(D) x 700(Ht)
having 2Drawers + 1Filling Drawer in each pedestal, the product should be from
BIFMA and FSC Certified Company, complete as per image specification under
the guidance of Engineer-in-Charge.
1 Each
(BILL OF QUANTITY)
FIRE-FIGHTING WORK
Item Rate Rate Amount
Description of work Unit
NO. Qty. in words In figures
Sub Head- FIRE FIGHTING SYSTEM
WET RISER SYSTEM
1 Supplying, Installation, Testing and commissioning of electric driven pump set
suitable for automatic operation as per specification as required & comprising
offollowing:-
a) 1 No horizontal foot mounted type Single stage centrifugal split casing pump of
cast iron body and bronze impeller with stainless steel shaft, mechanical seal and
capable of delivering 900 LPM at 56 m head complete with TEFC type squirrel cage
induction motor with class - F insulation , synchronous speed 3000 RPM continuous
duty, designed for operation on 415 +/- 10%, 50 HZ, 3 phase, AC supply with IP 55
class of protection confirming to IS:325 and duly coupled with the pumping set as per
specification.
b) M S fabricated common base plate fabricated from M S Channel of suitable size,
coupling, coupling guard, foundation bolt etc. as required.
c) Suitable cement concrete foundation including vibration isolation by providing
cushy foot mountings duly plastered complete as required.
2 set
5 Providing, Fixing including testing and commissioning of 100 mm dia pressure gauge
of range 0-15 Kg / Sq.cm. having burdon tube of stainless steel 310 in cast
aluminium,stove enameled, black weather proof case with outer, screwed aluminium
nozzle complete with necessary u-type stainless steel siphon tube and cock including
providing suitable painted angle iron support of the tube etc as required.
4 Each
6 Providing, Fixing, Testing and commissioning single headed stainless steel ISI
marked oblique pattern hydrant landing valve with 80mm dia flanged inlet and 63mm
dia instantaneous type female outlet complete with gum metal cap and chain and all
accessories as per IS-5290-1983.
12 Each
7 Providing Fixing, Testing and commissioning of 2 way fire service inlet with cabinet &
connection with 63 mm dia built in spring type non return coupling fitted on existing
100 mm dia G.I. pipe inlet header etc. as per specification complete as reqd.
1 Each
8 Providing and Fixing of 63 mm dia 15 mtr long (polyester fiber type) RRL hose pipe
Confirming to IS:636-1992 Part-II with male and female Gun metal couplings duly
binded with GI wire, rivets etc. as required. 12 set
10 Providing and fixing fire man axe as required complete in all respects. 6 Each
11 Providing and fixing 63 mm dia stainless steel branch pipe with 20 mm (nominal
internal diameter) as per IS:903 size stainless steel nozzle,suitable for instantaneous
connection to interconnect hose pipe coupling as required. 12 Each
(BILL OF QUANTITY)
FIRE-FIGHTING WORK
Item Rate Rate Amount
Description of work Unit
NO. Qty. in words In figures
12 Providing and fixing first aid hose reel with MS construction spray painted in post
office Red, with up-to-date amendments complete with the following as required :(a)
30m long 20mm (nominal internal) dia water hose Thermoplastic (Textile reinforced)
Type-2 as epr IS:444 with stainlees steel /gunmetal sgut off Nozzle having 5mm dia
orifice. (b) 20mm (nominal internal) dia stainless-steel globe valve & nozzle. (c)
Drum and brackets for fixing the equipment on wall. (d) Connections from riser with
25 mm dia ball valve .
6 Each
13 Providing and fixing the following sizes flanged type ISI marked non-return valves of
C.I. body and bronze/gun metal seat, complete with bolts, nuts, rubber insertions etc.
as required.
150 mm dia (horizontal) 4 Each
14 Providing and fixing following sizes ISI marked butterfly valves of cast iron body and
bronze/Stainless steel seat PN 1.6 complete with accessories such as nut, bolt,
rubber insertions complete with testing, commissioning etc. as required.
a 150nn dia 8 Each
b 80 mm dia 4 Each
15 Providing & Fixing Pump ON -OFF push button type remote switches at ground floors
i/c connection with multi core control wiring from starter panel as reqd. 2 Each
16 Supplying, Laying & Fixing on wall / surface one no. XLPE insulated, & PVC
sheathed armoured copper conductor cable of 1.1 KV grade on surface / cable tray
as required.
a) 4 x 2.5 Sq.mm+2x2.5 Sqmm earth wire 50 Mtrs
b) 2 x 6 Sq.mm+1x6 Sqmm earth wire 30 Mtrs
(BILL OF QUANTITY)
FIRE-FIGHTING WORK
Item Rate Rate Amount
Description of work Unit
NO. Qty. in words In figures
17 Fabrication, Supply, Installation, Testing and commissioniong of floor/wall mounted
compartmentalized with hinged lockable doors cubical electrical control panel of
suitable size fabricated from CRCA sheet of 2 mm thick, dust and vermin proof,
powder coated of approved shade after chemically treated with seven tank process,
cable alley, suitable for operation on 3 phase 415 volt 50 Hz AC supply i/c providing
and fixing following switch gear to be mounted on complete with gaskets,
interconnections and earthing etc. as required. The enclosure protection class shall
be of IP 54. ( For wet riser system) (General arrangement and schematic Drawings to
be approved by the department before start of fabrication)
Incomer
a) 100 ATPMCCB 35 KA, (ICS= ICU)-1 No
b) 100 A rating 4 strip tinned copper sleeved bus bar - 1 set
c) 1 set - multifunction digital meter to read V, Amp, KW,
KWH with 3 nos. Suitably rated CT's class 1.0
accuracy and 15 VA burden.
d) 3 Nos. Phase indication LED lamps with back up SPMCB.
Outgoing
a) 63 Amp TP MCCB, 10KA , (ICS= ICU) -2 nos.
b) Suitable DOL starter with over load protection, curent sensing type single phase
preventor complete with all accessories and internal wiring required for automatic
operation of terrace pumps - 2 Sets
c) Selector switch for local/remote, auto/ manual/off operation, push buttons for
ON,OFF, in manual mode, LED type ON/ OFF 3 phase indication lamps with Toggle
switch- 2 Sets
d) Digital ammeter with selector switch and suitable CT's - 2 Sets
1 set
18 Pdg. and fixing of following sizes stop/drain valve of Stainless Steel for testing the
drain system as required.
a) 40 mm dia ( in Delivery pumps.) 1 Each
19 Providing and fixing of cast iron Double flanged y type strainer of folloing size:
a 150mm 2 Each
(BILL OF QUANTITY)
FIRE-FIGHTING WORK
Item Rate Rate Amount
Description of work Unit
NO. Qty. in words In figures
Indoor type hose cabinet frames fabricated from 40x40x5 mm angle iron sections and
full front glass door and locking arrangment. Suitable to accommodate 2-nos landing
valve, 2-nos15mtr hoses1-no first aid hose reel and 1-no branch pipe. The cabinet
20
frame shall be painted with one coat of primer and two or more coat of synthetic
enamel paint of approved make and shade as required size 2x1.2mtr.
6 Each
Weather proof Hose Box fabricated out of 1.8 mm thick M.S. sheet complete with
21 glass in front having locking arrangement, suitable to accommodate all the necessary
fittings etc. 6 Each
Total
BILL OF QUANTITY
ELECTRICAL WORKS
Item DSR Rate Rate AMOUNT
S. No. Description of work Qty.
2014 Unit In words In Figures
SUB-HEAD-I-INTERNAL ELECTRICAL WORK
WIRING IN STEEL CONDUIT
1.1) 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point
with 1.5 sq.mm FRLS PVC insulated copper conductor single
core cable in surface / recessed steel conduit, with modular
switch,modular plate, suitable GI box and earthing the point with
1.5sq.mm. FRLS PVC insulated copper conductor single core cable
etc as required.
a) 1.3.3 Group C Point 605
1.2) N.S Wiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FRLS PVC insulated copper conductor single core cable
With modular switch, modular plate, suitable GI box and earthing
Point 190.00
the point with 1.5 sq.mm. FRLS PVC insulated copper conductor
single core cable etc as required in existing Conduit.
1.3) 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed
medium class PVC conduit, 2 way modular switch, modular
Point 15
plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.
1.4) 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular
switch, connection etc. as required. (For light plugs to be used in Each 223
non residential buildings).
1.5) 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
Each 99
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
1.6) 2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type,
socket outlet, with 2 pole and earth, metal enclosed plug top
alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure,
on surface or in recess, with chained metal cover for the socket
Each 12
out let and complete with connections, testing and commissioning
etc. as required.
1.9) 1.17 Supplying and drawing following sizes of FRLS PVC insulated
copper conductor, single core cable in the existing surface/
recessed steel / PVC conduit as required
a) 1.17.12 3 x 2.5 sq. mm Metre 700
b) 1.17.21 3 x 4 sq. mm Metre 650
c) 1.17.30 3 x 6 sq. mm Metre 400
1.1) 1.25 Supplying and fixing stepped type electronic fan regulator on the
existing modular plate switch box including connections but Each 9
excluding modular plate etc. as required.
1.11) 1.26 Supplying and fixing modular blanking plate on the existing modular
plate & switch box excluding modular plate as required. Each 150
TOTAL SUB-HEAD-I
SUB-HEAD-II-WIRING FOR T.V, TELEPHONE & DATA.
2.1) 1.24 Supplying and fixing following modular switch/ socket on the existing
modular plate & switch box including connections but excluding
modular plate etc. as required.
a) 1.24.6 Telephone socket outlet Each 35
b) 1.24.7 TV antenna socket outlet Each 2
b) NS RJ - 45 Jack computer socket outlet Each 42
2.2) 1.27 Supplying and fixing following size/ modules, GI box alongwith
modular base & cover plate for modular switches in recess etc as
required.
a) 1.27.1 1 or 2 Module (75mmX75mm) Each 77
2.3) 1.28 Supplying and fixing following Modular base & cover plate on
existing modular metal boxes etc. as required.
a) 1.28.1 1 or 2 Module Each 77
2.4) 1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC
insulated annealed copper conductor, unarmored telephone cable in
the existing surface/ recessed steel/ PVC conduit as required.
2.5) 1.18 Supplying and drawing Co-axial TV cable RG-6 grade, 0.7mm solid
copper conductor PE insulated, shileded with fine tinned copper
Mtrs 300
braid and protected with PVC sheath in the existing surface/
recessed steel/ PVC conduit as required.
2.6) 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the
Mtrs 1750
existing surface/ recessed steel/ PVC conduit as required.
2.7) 1.20 Supplying and fixing of following sizes of steel conduit along with
accessories in surface/recess including painting in case of
surfaceconduit, or cutting the wall and making good the same in
case of recessed conduit as required.
a) 1.20.1 20 mm Mtrs 4500
b) 1.20.2 25 mm Mtrs 8500
c) 1.20.3 32 mm Mtrs 1200
2.8) 1.21 Supplying and fixing of following sizes of medium class PVC conduit
along with accessories in surface/recess including cutting the wall
and making good the same in case of recessed conduit as required.
a) MR 10 Pair Each 3
b) MR 20 Pair Each 1
c) MR 100 Pair Each 1
3.0) MR Supply, laying, testing and commissioning of the following multi core
0.61 mm annealed tinned copper conductor PVC insulated and PVC
sheathed and overall PVC sheathed armoured/ unarmoured
telephone cables generally conforming to ITD s/WS-11-B and IS
1554 Part I as required and including making terminal joints,
complete as required.
a) MR 10 Pair Meter 350
b) MR 20 Pair Meter 155
TOTAL SUB-HEAD-II
3.3) 1.50 Installation of exhaust fan in the existing opening, including making
good the damage, connection, testing, commissioning etc. as
required.
3.4) 1.51 Extra for fixing the louvers/ shutters complete with frame for a
Each 15
exhaust fan of all sizes.
TOTAL SUB-HEAD-III
4.4) NS Supply ,fixing , testing and commissioning of 13W LED 2 feet tube
light/mirror Light fixture all accessories as required. Model: Havells
Cat No. LHDT15113631 or equivalent. Each 14
4.5) NS Supply ,fixing , testing and commissioning of 10W LED Bulk Head
Light fixture all accessories as required. Model: Bajaj Cat No.
BIBWP 10W LED or equivalent. Each 9
4.6) NS Supply ,fixing , testing and commissioning of 20W LED
Surface/Wall Mounted tube light fixture all accessories as
required.Model: Bajaj Cat No. BN150W LED20S-6500 PSE OD GR
or equivalent. Each 50
4.7) NS Supply ,fixing , testing and commissioning of 15W LED Surface
Mounted square downlight fixture all accessories as required.
Model: Bajaj Cat No. BGSLO Sleek Surface 15 WH SQ or
equivalent. Each 42
4.12) NS SIT and comminissioning Indoor emergency exit sign wall / pendent
mounting luminair with ihour backup complete with all accessories .
Viewing earter from one side for wall mounting type or viewing from
two sides suspended type all accessories as required. Model: Bajaj
Cat No.BESL 03 LED DSD WBB Red or equivalent.
Each 11
4.13) NS Supply, installation, testing and commissioning of LED Flexible Strip
light 4-5 Watt/mtr of approved color for indoor mounting with
transformer/Driver unit at every 5 mtrs complete in all respects.
Model: Bajaj Cat No. BCFL 300 25W IP20 or equivalent.
mtrs. 25
4.15) NS Supply of ISI marked energy efficient sweep ceiling fan with double
ball bearing , motor ,blades , down rod , canopies , capacitor etc .
Suitable for operation on 230 volts , 50 Hz. , single phase , AC
supply complete as required of and as per specifications attached
.(1200mm Sweep) Each 9
TOTAL SUB-HEAD-IV
2.9 Supplying and fixing following way prewired vertical type TP&N
MCB distribution board of steel sheet for 415 volts on
surface/recess complete with loose wire box of sheet steel, dust
protected, duly powder painted, inclusive of 200 amps tinned copper
bus bar, common neutral link, earth bar, din bar for mounting
MCB’s, terminal connectors for all incoming and outgoing circuits,
duly prewired with adequate size of FRLS PVC insulated copper
conductor upto the terminal connector/ neutral link, earthing etc as
required (But without MCB/ RCCB/ Isolator). (Note : Prewired
vertical type MCB TPDB is normally used where 3 phase outlets are
required.)
2.9.6 6 way Double door Each 1
5.3) 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C”
curve, miniature circuit breaker suitable for inductive load of
following poles in the existing MCB DB complete with connections,
testing and commissioning etc. as required.
5.4) 2.12 Supplying and fixing following rating, double pole, 240 volts,
isolatorin the existing MCB DB complete with connections, testing
andcommissioning etc. as required.
a) 2.12.2 63 amps Each 2
5.5) 2.13 Supplying and fixing following rating, four pole, 415 volts, isolator
in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
5.7) 2.11 Supplying and fixing single pole blanking plate in the existing MCB
DB complete etc. as required. Each 65
TOTAL SUB-HEAD-V
SUB-HEAD-VI-CABLE TRAYS
6.1) 4.1 Supplying and installing following size of perforated pre-painted
M.S. cable trays with perforation not more than 17.5%, in
convenient sections, joined with connectors, suspended from the
ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
6.6) MR Supplying and fixing of following recessed type raceway made out
of 2mm thich G.I sheet complete with joints, horizontal bends ,
vertical bends , level adjustment including cutting of floor & finishing
the same including actual size of Junction box etc. as required.
TOTAL SUB-HEAD-VI
SUB-HEAD-VII CABLES
7.3) M.R. Supply of following size of 1.1kv grade multicore aluminium
conductor XLPE insulated and PVC sheathed armoured cable as
per IS : 7098:1988 with upto date amendments.
(a) M.R. 3.5 core, 240 Sq.mm. Meter 120
(b) M.R. 3.5 core, 150 Sq.mm. Meter 120
(c) M.R. 3.5 core, 120 Sq.mm. Meter 150
(d) M.R. 3.5 core, 95 Sq.mm. Meter 200
(e) M.R. 4 core, 35 Sq.mm. Meter 240
(f) M.R. 4 core, 25 Sq.mm. Meter 300
7.4) 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refilling the trench etc as required.
7.5) 9.1 Supply and making end termination with flame proof double
compression brass gland and aluminium thimbles for XLPE
insulated and PVC sheathed aluminium conductor cable of 1.1kv
grade of the following sizes as required.
(a) 9.1.29 3½ X 240 sq. mm (62mm) Each 2
7.6) 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm,
made of mild steel, at least 2 mm thick, and vitreous enameled
white on both sides, and with inscription in single red colour on front
side as required. Each 4
7.7) 14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light
duty) in ground complete with RCC collars, jointing with cement
mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep)
and refilling etc as required.
14.14.2 150 mm dia. Meter 20
14.14.3 250 mm dia. Meter 20
TOTAL SUB-HEAD-VII
SUB HEAD VIII - LIGHTINING PROTECTION AND
EARTHING SYSTEM
8.1) 6.2 Providing and fixing of lightning conductor finial, made of 25mm dia
300mm, long GI tube, having single prong at top, with 85mm dia.
6mm thick GI base plate including holes etc. complete as required.
Each 4
8.2) 6.4 Jointing copper / G.I. tape (with another copper/ G I tape, base of
the finial or any other metallic object) by riveting / nut bolting/
sweating and soldering etc as required. Each 2
8.3) 6.7 Providing and fixing G.I. tape 20mm x 3mm thick on parapet or
surface of wall for lightning conductor as required (For horizontal
run) Metre 350
8.4) 6.8 Providing and fixing GI tape 20mm x 3mm thick on parapet or
surface of wall for lightning conductor as required. (for vertical run).
Metre 150
8.5) 6.12 Providing and fixing testing joint, made of 20mm x3mm thick GI
strip, 125mm long, with 4 nos. of GI bolts, nuts, check nuts and
spring washers etc.complete as required. Each 2
8.6) 6.14 Providing and laying GI tape, 32mm x 6mm thick, from earth
electrode directly in ground as required. Metre 150
TOTAL SUB-HEAD-VIII
9.5) 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe
from earth electrode including connection with G.I. nut, bolt, spring,
washer excavation and re-filling etc. as required. Meter 250
9.7) 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for
loop earthing as required. Meter 1500
TOTAL SUB-HEAD-IX
TOTAL SUB-HEAD-X
(b) M.R. Double side single left/ right arrow exit Each 5
TOTAL SUB-HEAD-XI
SUB-HEAD-XII : PA SYSTEM
Supply, Installation, Testing & Commissioning of IP based
Networkable touch screen paging station for selection of zones,
supervision of system status, setting of scheduled broadcasts with
12.1 M.R. Set
the following functions: Built-in monitoring loudspeaker, Detachable
goose-neck microphone, LCD touchscreen display complete as
required 1
Supply, Installation, Testing & Commissioning of 8 zone IP based,
digital Voice Alarm controller expandable upto 256 zones. The voice
alarm controller should be able to connect directly over existing
Ethernet. It should have functions like the audio playing, zone
12.2 M.R. control, fault monitoring, log recording, volume control and amplifier
Set
switchover. The Voice alarm controller should also have the
following functions: 255 Priorities, Time schedule broadcasts,
Capable of amplifier redundancy, 8 trigger inputs/outputs, 4
simultaneous audio messages per controller complete as required
1
TOTAL SUB-HEAD-XII
TOTAL SUB-HEAD-XIII