BASE PLATE ( I -TYPE ) Platine I - type

DESIGN INPUTS : Donnees de calcul b = 0.725 m


f = 10.53
LOADS: CHARGES D = 329.5 mm

Axial Compression in the column ( N ) = 14442 daN Load Case 36


Axial Tension in the column ( T ) = 11315 daN Load Case 37
Moment at the Base of the Column ( Mz ) = 15236 m-daN Load Case 50
Shear at the Base of the Column ( Fx ) = 4651.45 daN Load Case 39
Shear at the Base of the Column ( Fz ) = 3299.55 daN Load Case 50

Parameters PARAMETRES

Determination of Base Pressure :

a) Calculation of length of compression zone (yo):


490mm

tf

N
M

Ft yo

dt Pm

Where,

yo = Length of the compression zone


hp = Length of the Base Plate
bp = Width of the Base Plate
hc = Depth of column
bc = Width of column flange
tf = Thickness of column flange
tw = Thickness of column web
N = Axial compressive force in the column
M = Moment at the bottom of the column
At = Total sectional area of the anchor bolt
dt = Distance between the centre of anchor bolt to the CG of the section
n = Coefficient d' equivalence = Ea / Eb
where Ea = Modulus of elasticity of Steel
Eb = Modulus of elasticity of Concrete
Inputs :

hp = 750 mm
bp = 400 mm
hc = 490 mm
bc = 300 mm
tf = 23 mm
tw = 12 mm
N = 14442.108 daN
M = 15236.175 m-daN
Bolt (f) = 30 mm
Cross Spacing (s) = 200 mm
Cover = 75 mm
At = 1122 mm2 ( 2 Nos of 30 dia Bolts on either side )
n = 15 (Ea / Eb)
a2 = 55 mm
dt = 300 mm ( dt = a2 + hp/2)

To find the position yo of the neutral axis, we use the graph 1 (see annexe)

(dt+ M/N) = 2.01


(dt+ hp/2)

2 n At = 0.125
bp (dt+hp/2)
From the chart, the value of yo/(dt + hp/2) = 0.375

Yo = 253.125 mm

Base Pressure in the concrete : Pression sur beton

pm = 2(M + N dt)
bp yo (dt + (hp/2) - (yo/3))

= 0.6545 daN/mm2

pm = 65.45 daN/cm2

Maximum Tension in one Bolt:

Ft or Nj = M - N (hp/2 - yo/3)
2*(dt + (hp/2) - (yo/3))

Ft or Nj = 9345 daN

Verification de la resistance du beton

K.s bc = 2.126 > 0.6545 daN/mm2

pm < K.s bc Hence Safe

Average pressure on the concrete : Pression moyenne sur be'ton :

p = 2*N = 2 x 14442.108 x 10 = 0.963 N / mm2


bp hp 400 x 750
s bc = 0.85 fc28 = 0.85 x 25 = 14.17 N / mm2
1.5 1.5
p = k s bc = 1.5 x 14.17 = 21.26 N / mm2 > 0.963 N / mm2

Hence Ok

Check for Flange in Tension

Leff smaller of ( bc/2; pi*a2 ; (bc-s)/2 + (pi/2)*a2 ; (s/2)+ (pi/2)*a2 )

smaller of ( 150 172.85714286 136.42857 186.429 )

that is = 136.42857143

Nj = 9345 daN < Leff x tf x s e = 136.428571428571 x 23 x 26.5


= 43384.2857 daN

Hence Ok

Check for the Strength of Base plate

Side in Tension

M1 = 1027950 daN-mm (M1 = Nj (2 dt-hc )

V1 = 18690 daN (V1 = 2*Nj)

Side in Compression

p1 0.3 daN/mm2 (p1= pm (yo-hp/2+hc/2) /yo)

M2 1833086.7 daN-mm

V2 25285.0 daN

M3 327250.0 daN-mm

The maximum moment = 1833086.7 daN-mm


The maximum shear = 25285.0 daN

tp > 32.21 mm tp > (6 M2 / bp / sigma ep) 0.5

tp > 6.99 mm tp > (2.6 * V2 / bp / sigma ep)

Check for Rigidity of the Base plate


A Horizontal Vertical Horizontal Moment Moment G H
Node Env Fx DN Fy DN Fz DN Mx kg-m My kg-m Mz kg-m Mz kg-m
1 +ve 4645.433 11102.016 3299.547 15236.18 6.384 0
242 1.33*G39 1.33*G 50 1.33*G 50 1.33*G 32 1.33*G -
1 -ve -4651.447 -7737.287 -3299.547 -15236.18 -6.384 0
39 1.33*G 42 1.33*G 47 1.33*G 47 1.33*G 31 1.33*G -
4 +ve 388.279 14442.11 2483.357 10243.52 0 0
36 1.33*G 36 1.33*G 50 1.33*G 50 1.33*G - -
4 -ve -382.265 -11315.41 -2483.357 -10243.52 0 0
237 1.33*G37 1.33*G 47 1.33*G 47 1.33*G - -

A Horizontal Vertical Horizontal Moment Moment G H


Node Env Fx DN Fy DN Fz DN Mx kg-m My kg-m Mz kg-m Mz kg-m
1 +ve 3432.279 8228.529 2454.173 11364.13 4.424 0
449 1.0*G 440 1.0*G 445 1.0*G 445 1.0*G 431 1.0*G -
1 -ve -3436.801 -5698.658 -2454.173 -11364.13 -4.424 0
440 1.0*G 441 1.0*G 444 1.0*G 444 1.0*G 430 1.0*G -
4 +ve 284.451 10739.88 1842.027 7619.967 0 0
426 1.0*G 426 1.0*G 445 1.0*G 445 1.0*G - -
4 -ve -279.929 -8388.977 -1842.027 -7619.967 0 0
435 1.0*G 427 1.0*G 444 1.0*G 444 1.0*G - -
BASE PLATE

DESIGN INPUTS : Donnees de calcul

LOADS: CHARGES

Axial Compression in the column ( N ) = 14442 daN Load Case 36


Axial Tension in the column ( T ) = 11315 daN Load Case 37
Moment at the Base of the Column ( Mz ) = 10244 m-daN Load Case 36
Shear at the Base of the Column ( Fx ) = 4651.4 daN Load Case 39
Shear at the Base of the Column ( Fz ) = 3299.5 daN Load Case 50

Parameters PARAMETRES

Determination of Base Pressure :

a) Calculation of length of compression zone (yo):


490mm

tf
N
M

Ft yo

dt Pm

Where,

yo = Length of the compression zone


hp = Length of the Base Plate
bp = Width of the Base Plate
hc = Depth of column
bc = Width of column flange
tf = Thickness of column flange
tw = Thickness of column web
N = Axial compressive force in the column
M = Moment at the bottom of the column
At = Total sectional area of the anchor bolt
dt = Distance between the centre of anchor bolt to the CG of the section
n = Coefficient d' equivalence = Ea / Eb
where Ea = Modulus of elasticity of Steel
Eb = Modulus of elasticity of Concrete
Inputs :

hp = 750 mm
bp = 400 mm
hc = 490 mm
bc = 300 mm
tf = 23 mm
tw = 12 mm
N = 14442.108 daN
M = 10243.517 m-daN
Bolt (f) = 30 mm
Cross Spacing (s) = 200 mm
Cover = 75 mm
At = 1122 mm2 ( 2 Nos of 30 dia Bolts on either side )
n = 15 (Ea / Eb)
a2 = 55 mm
dt = 300 mm ( dt = a2 + hp/2)

To find the position yo of the neutral axis, we use the graph 1 (see annexe)

(dt+ M/N) = 1.50


(dt+ hp/2)

2 n At = 0.125
bp (dt+hp/2)
From the chart, the value of yo/(dt + hp/2) = 0.42

Yo = 283.5 mm

Base Pressure in the concrete : Pression sur beton

pm = 2(M + N dt)
bp yo (dt + (hp/2) - (yo/3))

= 0.4429 daN/mm2

pm = 44.29 daN/cm2

Maximum Tension in the Bolt:

Ft or Nj = M - N (hp/2 - yo/3)
2*(dt + (hp/2) - (yo/3))

Ft or Nj = 5334 daN

Design of Anchor Bolts : Calcul des boulons d'ancrage :

Diameter of the anchor bolt = 30 mm


Maximum tension in one bolt = 5334 daN
Area of the bolt used = 561 mm2
Allowable stress in the bolts = 26.5 daN/mm2
Allowable force in the bolt = 11893 daN > 5334 daN

Hence ok

Average pressure on the concrete : Pression moyenne sur be'ton :

p = 2*N = 2 x 14442.108 x 10 = 0.963 N / mm2


bp hp 400 x 750
s bc = 0.85 fc28 = 0.85 x 25 = 14.17 N / mm2
1.5 1.5
p = k s bc = 1.5 x 14.17 = 21.26 N / mm2 > 0.963 N / mm2

Hence Ok

Check for Flange in Tension

Leff smaller of ( bc/2; pi*a2 ; (bc-s)/2 + (pi/2)*a2 ; (s/2)+ (pi/2)*a2 )

smaller of ( 150 172.86 136.43 186.43 )

that is = 136.43

Nj = 5334 daN < Leff x tf x s e = 136.43 x 12 x 26.5


= 43384.7 daN

Hence Ok

Check for the Strength of Base plate

1 2 3
l3
H

H' s
2
1

Size of the Stiffener

Assume the thickness of base plate tp = 25 mm

Thickness of Stiffner e = 10 mm