Wiring Diagram
C0-12DD2E-D
24VDC
C1
X1
See Discrete I/O Specifications
+
X2
PWR RUN
R UN Inputs (X1 – X4)
+
X3
RUN X4
ERR STOP
S TOP V1
Y1 L 24
PORT1
VDC
Y2 L See Discrete I/O Specifications
+
LNK/ACT
L
ETHER Y3 Outputs (Y1 – Y4)
NET Y4 L
100MBIT
CO
AD1V Transmitter 0-5V
PORT2 See Analog I/O Specifications -
AD1 I Transmitter 4-20mA
TX2
AD2V Transmitter 0-5V
Voltage & Current
RX2
AD2 I Transmitter 4-20mA
Input (AD1V – AD2I)
RS-232
RS 232
ACOM
RS-485
RS-
-485
485
5 DA1V
PO
ORT3
PORT3
See Analog I/O Specifications -
TX3
TX
X3
+
_
DA1 I
Voltage & Current
DA2V
RX
X3
RX3
LG
G DA2 I Output (DA1V – DA2I)
+
Transmitter
P/S
NOTE: There are no ZIPLink pre-wired PLC connection cables and modules for the Analog
PLCs (cannot mix discrete I/O and analog I/O signals in a ZIPLink cable).
NOTE: When using Ethernet Analog PLCs, you must use CLICK programming software
version V2.20 or later.
IMPORTANT: use only one terminal (voltage or current) per channel. You
must also select the analog type (voltage or current) in the CPU built-in I/O
setup in the CLICK programming software
(pull-down menu Setup > CPU Built-in I/O Setup).
General Specifications
Current Consumption at 24VDC 140mA
Terminal Block Replacement Part No. C0-16TB
Weight 5.08 oz (144g)
Points
2
Status Indicators Logic Side (4 points, green LED)
1
Commons 1 (4 points/common)
0
0 10 20 30 40 50 55 °C
32 50 68 85 104 122 131 °F
Ambient Air Temperature (°C/°F)
Y1 - Y4
Discrete I/O Specifications - Outputs Equivalent Discrete Output Circuit
0
0 10 20 30 40 50 55 °C
32 50 68 85 104 122 131 °F
Ambient Air Temperature (°C/°F)
+
Transmitter P/S
18-30 VDC
C0-4AD2DA-1 C0-4AD2DA-2
0-20mA In 0-10V
4-20mA Out
CH1 CH1
0V 0V
INPUT
INPUT
CH2 CH2
0V 0V
CH3 CH3
0V 0V
CH4 CH4
0V 0V
CH1 CH1
0V 0V
OUTPUT
OUTPUT
CH2 CH2
0V 0V
24V 24V
0V 0V
C0-4AD2DA-1 C0-4AD2DA-2
These general specifications apply to all Acceptable External Power Drop Max 10ms
Analog, analog combo I/O modules only:
CLICK PLCs, optional I/O modules, and 32°F to 140°F (0°C to 60°C);
optional power supply products. Please Operating Temperature All other modules:
32°F to 131°F (0°C to 55°C),
refer to the appropriate I/O temperature IEC 60068-2-14 (Test Nb, Thermal Shock)
derating charts under both the PLC and –4°F to 158°F (–20°C to 70°C)
I/O module specifications to determine IEC 60068-2-1 (Test Ab, Cold)
Storage Temperature IEC 60068-2-2 (Test Bb, Dry Heat)
best operating conditions based on the IEC 60068-2-14 (Test Na, Thermal Shock)
ambient temperature of your particular Ambient Humidity 30% to 95% relative humidity (non–condensing)
application. Environmental Air No corrosive gases. Environmental pollution level is 2 (UL840)
MIL STD 810C, Method 514.2, EC60068-2-6
Vibration JIS C60068-2-6 (Sine wave vibration test)
Shock MIL STD 810C, Method 516.2, IEC60068-2-27, JIS C60068-2-27
Comply with NEMA ICS3-304, Impulse noise 1μs, 1000V
EN61000-4-2 (ESD), EN61000-4-3 (RFI), EN61000-4-4 (FTB)
Noise Immunity EN61000-4-5 (Surge), EN61000-4-6 (Conducted)
EN61000-4-8 (Power frequency magnetic field immunity)
RFI: No interference measured at 150 and 450 MHz (5w/15cm)
Emissions EN55011:1998 Class A
Agency Approvals UL508 (File No. E157382, E316037); CE (EN61131-2)
Other RoHS
CLICK Specifications
CLICK Specifications
PLC Units Specifications (continued)
Ethernet Basic, Standard and Analog PLC Unit Specifications
Ethernet Basic PLC Ethernet Standard PLC Ethernet Analog PLC
Control Method Stored Program/Cyclic execution method Stored Program/Cyclic execution method Stored Program/Cyclic execution method
I/O Numbering System Fixed in Decimal Fixed in Decimal Fixed in Decimal
Ladder Memory (steps) 8000 8000 8000
Total Data Memory (words) 8000 8000 8000
Contact Execution (boolean) < 0.2 µs < 0.2 µs < 0.2 µs
Typical Scan (1k boolean) < 1ms < 1ms < 1ms
RLL Ladder Style Programming Yes Yes Yes
Run Time Edits Yes Yes Yes
Scan Variable / fixed Variable / fixed Variable / fixed
CLICK Programming Software for Yes Yes Yes
Windows
Yes (one Ethernet port and Yes (one Ethernet port, one RS-232 port and Yes (one Ethernet port, one RS-232 port and
Built-in Communication Ports one RS-232 port) one RS-485 port) one RS-485 port)
FLASH Memory Standard on PLC Standard on PLC Standard on PLC
Built-in Discrete I/O points 8 inputs, 6 outputs 8 inputs, 6 outputs 4 inputs, 4 outputs
Built-in Analog I/O Channels No No 2 or 4 inputs; 2 outputs
Number of Instructions Available 21 21 21
Control Relays 2000 2000 2000
System Control Relays 1000 1000 1000
Timers 500 500 500
Counters 250 250 250
Interrupt Yes (external: 8 / timed: 4) Yes (external: 8 / timed: 4) Yes (external: 8 / timed: 4)
Subroutines Yes Yes Yes
For/Next Loops Yes Yes Yes
Math (Integer and Hex) Yes Yes Yes
Drum Sequencer Instruction Yes Yes Yes
Internal Diagnostics Yes Yes Yes
Password Security Yes Yes Yes
System Error Log Yes Yes Yes
User Error Log No No No
Memory Backup Super Capacitor + Battery Super Capacitor + Battery Super Capacitor + Battery
Battery Backup Yes (battery part # D2-BAT-1) Yes (battery part # D2-BAT-1) Yes (battery part # D2-BAT-1)
Calendar/Clock Yes Yes Yes
I/O Terminal Block Replacement ADC p/n C0-16TB ADC p/n C0-16TB ADC p/n C0-16TB
Communication Port & Terminal N/A ADC p/n C0-3TB ADC p/n C0-3TB
Block Replacement
24 VDC Power Terminal Block ADC p/n C0-4TB ADC p/n C0-4TB ADC p/n C0-4TB
Replacement
CLICK Specifications
PLC Features
Basic PLCs Standard PLCs
Mounting Mounting
Tab Tab
Sliding Sliding
Latch Latch
PLC Mode PLC Mode C0-01DD1-D
Switch Switch
8 Discrete 8 Discrete
Input Input
LED Status Points LED Status Points
Indicators
PWR
Indicators RUN
ERR
PORT1
TX1
RX1
Communication
Ports
Communication
TX2
TX3
RX3
Sliding Sliding
Latch Latch
Power Power
Terminal Mounting Terminal Mounting
24V Tab 24V Tab
0V 0V
N.C. N.C.
G G
Analog PLCs
Sliding
Latch
PLC Mode C0-02DD1-D
Switch C1
X1
4 Discrete
X2
Inputs
X3 Power
LED Status PWR X4 Terminal
al
Indicators RUN C2
ERR Y1 4 Discrete 24V
Y2 Outputs 0V
PORT1
TX1
Y3
Y4
N.C.
RX1 +V G
AD1V 2 Analog
Communication
TX2
RX2
AD1II
AD1 Inputs
AD2V
Ports PORT2
AD2II
AD2
ACOM
PORT3
RS-485
DA1V 2 Analog
TX3 DA1II
DA1 Outputs
RX3 DA2V
DA2II
DA2
Sliding
Latch
Power
Terminal Mounting
24V Tab
0V
N.C.
G
CLICK Specifications
PLC Features (continued)
Mounting Mounting
Tab Tab
S
Sliding Sliding
Latch
L C0-11DD1E-D
C0-11DD1E-
Latch
C0-10DD1E-D
C0-10DD1E-
-D
D PLC Mode 01DD1-D
-D
PLC Mode C0-01DD1-D
C0-
C0 01DD1 D
Switch Switch C1
1
C1
X1 8 Discrete X1
1 8 Discrete
X2
2
Input
X2
2
Input
LED Status PWR RUN
RUN X3
3
Points LED Status PWR
RUN
RUN
RUN X3
3
Points
X4
4
Indicators
RUN R
PWR
X4
4
Indicators ERR STOP
STOP C2
2
RUN
ERR STOP
STOP C2
2
ERR
PORT1 X5
5
PORT1 X5
5
LNK/ACT X6
6
LNK/ACT X6
6
PO
PORT
ORT1
ORT1
PORT1
ETHER X7
7
ETHER X7
7
NET
TX
TX
X1
TX1 X8
8
NET X8
8 100MBIT
100MBIT RX
X
X1
RX1
Communication C3
3
Ports PORT2
C3
3 PORT2
X2
TX2 Y1
1
TX2
Y1 Communication TX2
Y2
2 6 Discrete
Y2
2 6 Discrete Ports
X
RX2
RX2
RX2
Y3
3 Output
PORT2
PORT2
RS 232
RS-232
Y3
3 Output
RS-232
RS 232
Y4
4
Points RS-485
R
RS-4
RS-485
S
S-4 85 5
485
Y4
4
Points
PO
PO RT3
PORT3
ORT
ORT3
T3 C4
4
C4
4
Y5
5 TX
X3
TX
TX33
+
_
Y5
5
Y6
6
Y6
6 RX
RX
X3
3
RX3
LG
G +V
V
+V
V
S
Sliding Sliding
Latch
L Latch
Power
wer Power
Terminal
rminal Mounting Terminal Mounting
24V Tab 24V Tab
0V 0V
N.C. N.C.
G G
Sliding
PLC Mode C0-12DD1E-D Latch
Switch C1
X1 4 Discrete
X2
Inputs Power
LED Status PWR RUN
R UN X3
Sliding
Latch
Power
Terminal
Removeable Screw Type
24V Terminal Block
0V
N.C. Mounting
G Tab
CLICK Specifications
PLC LED Status Indicators
Basic CPUs
POWER LED (Green) Basic PLC
On Power Good
Off Power Failure
Standard PLC
POWER LED (Green) Standard CPUs
On Power Good
Off Power Failure
Error RX1
PORT3
RS-485 On Output True
TX & RX LED (Green)
TX3 Off Output False
On Comm Port Data Active RX3
Off No Communication
Analog PLC
POWER LED (Green)
Analog CPUs
On Power Good
Off Power Failure
Initializing X2
Off Input False
Blink System X3
Self Diagnostic
Blink Warning
AD1V
TX2 AD1 I
RX2 AD2V
Off No Error PORT2
AD2 I
ACOM
RS-485
PORT3 DA1V
TX & RX LED (Green)
TX3 DA1 I
On Comm Port Data Active RX3 DA2V
DA2 I
Off No Communication
CLICK Specifications
PLC LED Status Indicators
POWER LED (Green)
On Power Good Ethernet Basic PLC
Off Power Failure Ethernet Basic CPU
RUN LED (Green) C0-10DD1E-D
C0-10D D1E--D
D
Blink Communicating
Blink Communicating
CLICK Specifications
On Input True
Off Input False
Note: There are no LED indications
on the Analog I/O modules.
Mounting Orientation
CLICK PLCs must be mounted prop-
erly to ensure ample airflow for cooling
purposes. It is important to follow the
unit orientation requirements and to verify
that the PLC’s dimensions are compatible
STOP
RUN
PORT2
RX1
TX1
RUN
RX2
TX2
PWR
ERR
9.4
[0.37]
9.2
[0.36]
Power Supply
Unit Dimensions
mm [inches]
PLC Units
I/O Modules
1
Station Address: 1
left of each communications port to 5 NC No connection
Data length: 8 bits
6 0V Power (-) connection (GND)
6
indicate when the port is transmitting or Stop bit: 1
receiving. Protocol: Modbus RTU (slave only)
1
On The Comm Port is sending data. PORT1 Parity: odd, even, none Odd 5 RTS Request to send
TX1
Off The Comm Port is not sending data.
Station Address: 1 to 247 1
RX1
6 0V Power (-) connection (GND)
Data length: 8 bits (Modbus RTU) or 6
RX1 and RX2 (Green)
TX2
RX2 7, 8 bits (ASCII) 8 bits
On The Comm Port is receiving data. PORT2
Stop bit: 1,2 1
Off The Comm Port is not receiving data.
Protocol: Modbus RTU Modbus RTU
(master/slave) or ASCII in/out
PORT1
Communication speed (baud): 1200, (RS-485)
TX1, TX2 and TX3 (Green) TX1 2400, 4800, 9600, 19200, 38400, 38400 Signal B
57600, 115200 2 - (minus)
On The Comm Port is sending data. RX1
(RS-485)
Off The Comm Port is not sending data. TX2 Parity: odd, even, none Odd Logic
RX2 3 LG Ground(0 V)
PORT2 Station Address: 1 to 247 1
RX1, RX2 and RX3 (Green)
PORT3
RS-485 Data length: 8 bits (Modbus RTU) or 8 bits
On The Comm Port is receiving data.
TX3
7, 8 bits ( ASCII)
Off The Comm Port is not receiving data. RX3
Stop bit: 1,2 1
Protocol: Modbus RTU Modbus RTU
(master/slave) or ASCII in/out
Port Setup
Use CLICK programming software to
easily configure the communications
ports.
Built-in Communications
Ports
Ethernet Basic, Standard and Analog PLCs
have one built-in Ethernet communications Com Port 1 Com Port 1
port and one RS-232 communications
port. Ethernet Standard and Analog PLCs Com Port 2
also have one built-in RS-485 communica- Com Port 2
tions port. The Ethernet port supports the Com Port 3
Modbus TCP protocol. The RS-232 and
Ethernet Basic PLC Ethernet Standard and
RS-485 ports support either Modbus RTU or Ethernet Analog PLCs
ASCII protocol. The RS-232 port supplies
5 VDC, so you can connect a monochrome Port 1
Com Port 1 Specifications Port 1 Pin Descriptions
C-more Micro HMI panel without an addi- Use: Programming and Ethernet Communication 1 TX+ Transmit Data (+)
tional power supply. 8 pin RJ45
8 pin Phone
RJ45
Physical: 8 pin, RJ45, Ethernet Type Jack 2 TX- Transmit Data (-)
Communication speed (Mbps): 10/100 3 RX+ Receive data (+)
LED Status Indicators Protocol: Modbus TCP 4 NC Not connected
1
There are LED indicators located to 5 NC Not connected
the left of each communication port to 6 RX- Receive Data (-)
8
indicate when the port is transmitting or 7 NC No connection
receiving. 8 NC No connection
Com Port 2 Default Port 2
Ethernet Basic PLCs
Specifications
Use: Serial Communication -
Port 2 Pin Descriptions
Port 11 &
Port & 22 LED
LED
66pin
pin RJ12
RJ12 Phone
Phone 1 0V Power (-) connection (GND)
Physical: 6 pin, RJ12, RS-232 - Type Jack
Type Jack
StatusIndicators
Status Indicators 2 5V Power (+) connection
Communication speed (baud): 2400,
LNK/ACT LED (Green) PWR RU
R
RUN 4800, 9600, 19200, 38400, 57600, 38400 3 RXD Receive data (RS-232)
115200
1
4 TXD Transmit data (RS-232)
RUN
On Connected to the network ERR S
STOP
Blink Communicating
PORT1 Parity: odd, even, none Odd 5 RTS Request to send
LNK/ACT
6
Off Disconnected from the network
ETHER
NET
Station Address: 1 to 247 1 6 0V Power (-) connection (GND)
Data length: 8 bits (Modbus RTU) or
100MBIT
RX2 (Green)
Com Port 3 Port 3
Default Port 3 Pin Descriptions
On The Comm Port is receiving data.
Specifications RS-485
RS-485
Off The Comm Port is not receiving data. Signal A
Use: Serial Communication - 1 + (plus)
(RS-485)
Physical: 3 pin, RS-485 - Signal B
Ethernet Standard and 2 - (minus)
Communication speed (baud): 2400, (RS-485)
Ethernet Analog PLCs 4800, 9600, 19200, 38400, 57600, 38400 Logic
Port 1, 2 & 3 LED 115200 3 LG Ground(0 V)
Port 1, Indicators
Status 2, & 3 LED Parity: odd, even, none Odd
Status Indicators
Station Address: 1 to 247 1
LNK/ACT LED (Green)
On Connected to the network
Data length: 8 bits (Modbus RTU) or 8 bits
7, 8 bits ( ASCII)
Blink Communicating
Stop bit: 1,2 1
Off Disconnected from the network
Protocol: Modbus RTU
RUN
ERR
PORT1
STOP
(master/slave) or ASCII in/out Modbus RTU
100MBIT LED (Orange)
LNK/ACT
On Communicating at 100Mbps ETHER
NET
100MBIT
Off Communicating at 10Mbps or
disconnected from the network
PORT2
TX2
RS-485
Port Setup
On The Comm Port is sending data. PORT3
Port 1
CLICK PLC
Port 1
NOTE: CLICK’s (RS-232) Port 1 and Port 2 can provide 5 VDC power to the panel, but not at the same time. If a C-more Micro-Graphic
panel is connected to both ports, then at least one of the panels must be powered by a C-more Micro DC power adapter, EA-MG-P1
or EA-MG-SP1, or another 24 VDC power source. Color C-more Micro-Graphic panels must also be powered from a separate 24 VDC
source.
Do not use the following Direct LOGIC devices with CLICK’s Port 1 or 2:
Warning: The following DirectLOGIC PLC devices cannot be used with a CLICK PLC’s Port 1 or Port 2:
Handheld Programmer for DL05, DL06, DL105, DL205 & D3-350 CPUs, p/n D2-HPP
Handheld Programmer for DL405 CPUs, p/n D4-HPP-1
Timer/Counter Access for DL05, DL06, DL105, DL205, DL405 & D3-350 CPUs, p/n DV-1000
D2-HPP DV-1000
D4-HPP-1
Another CLICK
PC
Ethernet PLC
All CLICK
Ethernet PLCs Other Devices
Supporting
Modbus TCP
Client Mode
C-more Panel
Another CLICK
Ethernet PLC
Port 2
Port 2
Port 3
Modbus RTU
Modbus RTU Master Devices
Other Devices
C-more and C-more Supporting Modbus RTU
Micro-Graphic Panel Master Mode
ASCII
Devices that SEND ASCII messages
Other devices
that can send Modbus RTU Slave Devices
ASCII data.
Barcode
Weigh Scale
Reader
Other Devices
Supporting Modbus
RTU Slave Mode
Power Supplies
Power Supplies
The CLICK PLC family offers two 24 VDC CLICK 24 VDC Power Supply Ratings
Part Number Output Current Price C0-00AC
power supplies. They are identical except
for the output current. C0-00AC 0.5 A $29.00
C0-01AC 1.3 A $39.00
It is not mandatory to use one of these
CLICK power supplies for the CLICK PLC C0-00AC Power Supply Specifications
system. You can use any other 24 VDC
Input Voltage Range 85-264 VAC
power supply that Automationdirect.com
Input Frequency 47-63 Hz
offers, including the PSP24-DC12-1 12
Input Current (typical) 0.3 A @ 100 VAC, 0.2 A @ 200 VAC
VDC to 24 VDC converter shown below.
Inrush Current 30 A
C0-00AC Power Supply Output Voltage Range 23-25 VDC
Output Current 0.5 A
Limited auxiliary AC power supply allows Over Current Protection @ 0.65 A (automatic recovery)
you to power the 24 VDC CLICK C0 series Weight 5.3 oz (150g)
PLCs with 100-240 VAC supply power.
The 0.5A DC power supply is capable of
controlling the PLC plus a limited configu- C0-01AC Power Supply Specifications 24 VDC
Input Voltage Range 85-264 VAC Output Power
ration based on the power budget of each Terminals
I/O module. The C0-00AC is a low- Input Frequency 47-63 Hz
(for CLICK PLC, I/O or
cost solution for applications requiring Input Current (typical) 0.9 A @ 100 VAC, 0.6 A @ 200 VAC field device, etc.)
only minimal I/O and power consump- Inrush Current 30 A
85-264 VAC
tion. This power supply will not support a Output Voltage Range 23-25 VDC
Power Source
fully-populated CLICK PLC system with all Output Current 1.3 A
Input Terminals
possible I/O module combinations. Over Current Protection @ 1.6 A (automatic recovery)
Weight 6.0 oz (170g)
C0-01AC Power Supply
Expanded auxiliary AC power supply allows PSP24-DC12-1 DC-DC Converter Specifications
C0-01AC
you to power the 24 VDC CLICK C0 series Input Voltage Range 9.5-18 VDC
PLCs with 100-240 VAC supply power. Input Power (no load) 1.0 W max.
The 1.3A DC power supply is capable Startup Voltage 8.4 VDC
of supporting a fully-populated CLICK Undervoltage Shutdown 7.6 VDC
PLC system with all possible I/O module Output Voltage Range 24-28 VDC (adjustable)
combinations, with no concerns for Output Current 1.0 A
exceeding the power budget. Short Circuit Protection Current limited at 110% typical
Weight 7.5 oz (213g)
PSP24-DC12-1 DC-DC Converter
With this DC-DC converter you can
operate the CLICK PLC with 12 VDC input CLICK Power Supply CLICK PLC
power.
24 VDC
Output Power
Terminals
(for CLICK PLC, I/O or
field device, etc.)
85-264 VAC
Power Source
Input Terminals
Power Budgeting
Power Budgeting
There are two areas to be considered when determining the It is strongly recommended that the power source for the logic
power required to operate a CLICK PLC system. The first area side be separate from the power source for the field side to help
is the power required by the CLICK PLC, along with the internal eliminate possible electrical noise.
logic side power that the CPU provides to its own I/O and any Power budgeting requires the calculation of the total current the
connected I/O modules that are powered through the PLC 24 VDC power source needs to provide to CLICK’s logic side,
expansion port; plus any device, such as a C-more Micro-Graphic and also a separate calculation of the total current required for all
panel, that is powered through one of the communications ports. devices operating from the field side of the PLC system.
The second area is the power required by all externally connected Refer to the Power Budgeting example shown on the following
I/O devices. This should be viewed as the field side power page. The table shows required current for a CLICK PLC, two
required. The field side power is dependent on the voltage used I/O modules, and a C-more Micro. Use the total amperage
for a particular input or output device as it relates to the wired values to select the properly sized power supply.
I/O point, and the calculated load rating of the connected device.
Power Budgeting
Power Consumption for I/O Module Current Consumption
CLICK I/O Expansion Modules (continued) (mA)
Power Budget External
I/O Module Current Consumption (mA) Part Number 24 VDC 24 VDC
(logic side) (field side)
Power Budget External
Part Number 24 VDC 24 VDC Discrete Combo I/O Modules
(logic side) (field side) C0-16CDD1 80 50
Discrete Input Modules C0-16CDD2 80 0
C0-08ND3 30 0 C0-08CDR 80 0
C0-08ND3-1 30 0 Analog Input Modules
C0-16ND3 40 0 C0-04AD-1 20 65
C0-08NE3 30 0 C0-04AD-2 23 65
C0-16NE3 40 0 C0-04RTD 25 0
C0-08NA 30 0 C0-04THM 25 0
Discrete Output Modules Analog Output Modules
C0-08TD1 50 15 C0-04DA-1 20 145
C0-08TD2 50 0 C0-04DA-2 20 85
C0-16TD1 80 100 Analog Combo I/O Modules
C0-16TD2 80 0 C0-4AD2DA-1 25 75
C0-08TA 80 0 C0-4AD2DA-2 20 65
C0-04TRS 100 0 C-more Micro-Graphic Panel
C0-08TR 100 0 Monochrome
90 0
only
C-more
Micro-Graphic
Panel
Only monochrome models
can be powered from port 1 or 2.