WATER TREATMENT PLANT [WTP] SCADA

Quality assurance and efficiency


Of Water Treatment Plant [WTP]
Operational

COMPLIANT TO
 SNI 6775:2008 Tata cara pengoperasian dan pemeliharaan unit paket Instalasi Pengolahan Air
 SNI 6774:2008 Tata cara perencanaan unit paket instalasi pengolahan air
 SNI 6773:2008 Spesifikasi unit paket instalasi pengolahan air
 Permenkes Nomor 492 Tahun 2010
Water for life
Water is a basic human need. It is a common assumption in which we find
water, then there is no hope for life. The amount of water is limited and the
increasing number of humans caused the water crisis.

SCADA
SCADA (supervisory control and data acquisition) is a type of industrial control system
(ICS). Industrial control systems are computer controlled systems that monitor and con-
trol industrial processes that exist in the physical world. SCADA systems historically dis-
tinguish themselves from other ICS systems by being large scale processes that can in-
clude multiple sites, and large distances .

RIFIER I (300 LPS)


SEDIMENT TANK - CLA

Level228 cm
TBDT 4.5 NTU

pH 6.7

Turbidit
y 17
5 NTU Turbidit
y 1.
5 NTU
WTPA
WTPA (Water Treatment Plant Automation) is a type SCADA in water industries. The
processes involved in treating water for drinking purpose may be solids separation using
physical processes such as settling and filtration, and chemical processes such as disin-
fection and coagulation. A combination selected from the following processes is used for
municipal drinking water treatment worldwide:
1. Coagulation & flocculation
2. Coagulator, P&ID control for dosing Pump.
3. Sedimentation / clarifier valve control.
4. Automatic Back washing for Filtration
5. Desalination (optional process)
6. Disinfection - for killing bacteria. Free chlorine online meter.
Expansible Integration into:
 Reverse Osmoses System (RO)
 Ultrafiltration System
 Dissolved Oxygen Monitoring
Special Design

WTPA - SCADA
The main purpose of automation for efficiency and safety, the best quality
of water as a outcome of processing water treatment warranty by SCADA.
Engineering—Purchasing—and Construction as
integrated services offering best WTPA SCADA

General
AUTOMATICS PUMP CONTROL for INTAKE &
DISTRUBUTION
Electronic pump controller at variable speed, for single and multiple
pump applications, it offers :
 energy savings
 PID controlling variable depend on load
 comfort of constant pressure
 selectable pressure

METERING SYSTEM
Metering System supports reading flow for raw water and water
treatment outcomes. There are numerous benefits to using
electronics flow meters to perform fluid flow measurements, such
as electromagnetic, ultrasonic flow meter . They are generally non-
invasive and have no moving parts, reducing the risk of
breakdowns and the frequency of repairs.

Automatic Dosing Coagulant


Pump controlling dose over stroke length and stroke rate. PLC
integrated into Current Streaming Monitor (SCM) to feedback dosing
control (PID– Proportional Integral Derivative). Automatic Dosing
can be decreasing Chemical Coagulant up to 30% than manual

Streaming Current Monitor


Streaming Current Monitor establishes a new level of control for plant
operators that depend on Streaming Current to maintain water quality
by chemical treatment dosing control.
the number of flock during treatment of raw water measured, with
feedback control will optimize the use of chemical coagulants.
Range : ± 10.00 ICu (SCU)
Resolution : 0.01 ICu (SCU)
Accuracy : ± 1% of full scale
Response time : 1 second
Analog output : 4-20 mA
Digital outputs : RS-232 /485 serial
Display : Graphical trending and
numeric

pH online reading
Specially designed for water treatment applications where both pH and ORP need to be
monitored. read pH conditions will determine the pretreatment of raw water.
Range : 0 to 14 pH
Resolution : 0.01 pH
Accuracy : 0.014 pH
Step Response Time : 90% in 30 seconds
Turbidity
Raw water turbidity readings condition is critical, performance will be measured
on the coagulant dose when turbidity levels change.
one of the water quality criteria measured turbidity level, so the online turbidity
monitoring is essential. Option range of measurement:: 0-100 NTU, 0-1,000 NTU
and 0– 9999 NTU.

Dissolved Oxygen
Raw water turbidity readings condition is critical,
Sensor Type Luminescent dissolved oxygen sensor
Transmitter/local display Optional, not required
Range : 0 to 20 mg/L concentration
0 to 200% saturation
Accuracy : (DO) ±0.1 mg/L, 0 to 8 mg/L
±0.2 mg/L, 8 to 20 mg/L
Response time, cap T90 : 30 sec T95: 37 sec @ 25°C
Resolution : 0.01 mg/L

Water Level Transmitter


Level sensors for measuring the level in sedimentation tanks, filter compartment
and reservoir volume monitoring storage.
Range : 0 to 20 m concentration
Accuracy : 3 to 150 mm
Other type of level instrument are sludge Finder, used for detection leveling
sludge in the bottom of sedimentation basin.
Pneumatic Operating Valve
The advantages of WTP automation solution using valve control:
 Significant savings with regard to installation
 Consistent operation for backwashing, sludge disposal in filter
 Control elements are combined on the valve terminal
 Automatic feedback control by variant sensor (sludge / pressure)
 Easily remote control & monitoring
Area to be controlling:
1. Flocculation / slow mixing area
2. sedimentation / clarifier
3. filtration

Residual Chlorine meter online


disinfectant Technique are using chlorine gas or powder, The main health effect
that comes from drinking too much chlorinated water is bladder cancer. Drinking
chlorinated water over a long period of time may also cause a person to develop
asthmatic conditions. As PERMENKES RI No. 492 2010, maximum residual
chlorine in drinking water is 5 mg/liters.
FUTURE SYSTEM
Industrial technology bring a life better, for future both of management can monitoring at
multiple sites, and in long distances. This solution ready is based on best technology with its
high speed performance and large data volume capability. It offers state-of-the-art Fault De-
tection and Diagnostics (FDD) technology, identifies equipment and energy inefficiencies
and provides possible causes that help in predicting plant operations. With this solution, one
can provide role-based analytics and intelligence across operations and the water-
based enterprise.
Easily customizable Web portals enable comprehensive, personalized visibility of
your operations, maintenance and financial information, to help make decisions.
Visualize your enterprise from anywhere, anytime and on any device.
Designed around the international standard for data exchange and FDD technolo-
gy for continuous commissioning to your operations, solution includes the follow-
ing major features:
1. Role-based Portal for Analysis & Forecasting
2. Water Operations and Enterprise Reporting
3. Integration of Financial & Operational Data
4. Interfaces with Microsoft SQL Server, SAP, Oracle and IBM databases
5. Predict, Reduce and Eliminate Equipment Downtime Before it Happens
6. Reduces Equipment Downtime, Improves Operational Efficiency by 50%
7. Reduces Energy and Maintenance Costs by Asset Optimization
8. Uses Microsoft SharePoint® Collaboration and Social Networking Technology
9. Be Notified “Anywhere, Anytime and On Any Platform” with Microsoft Silverlight®
10.Real-time Alerts of Faults Using Email, SMS Messages and Web Browsers
11. Advanced Notifications of Probable Causes for Improved Reliability and Control
12.GIS integration, geographical interfacing data

PT.TRICOTEKNOLOGIUTAMA
Perumahan Batununggal Indah Phone : +62-22-7564077
Jl.Batununggal Indah Raya no 21 A Fax : +62-22-7564048
Batununggal - Bandung E-mail : customercare@tricoteknologi.com