USER INSTRUCTIONS

Automax WS/WM Ultraswitch™ Installation


Switchbox
Operation
Maintenance
FCD AXENIM0135-02 - 09/16
FCD AXENIM0135-02 - 09/16

CONTENTS
1. GENERAL INFORMATION..................................................................................... 3

2. SAFETY INSTRUCTION........................................................................................ 3

3. UNPACKING..................................................................................................... 3

4. CERTIFICATES.................................................................................................. 4

5. SPECIFICATIONS............................................................................................... 4
5.1 Technical data.................................................................................................................................. 4
5.2 Materials of construction................................................................................................................. 4
5.3 Product label.................................................................................................................................... 4
5.4 WS/WM UltraSwitch™ nomenclature............................................................................................... 5
5.5 WS/WM UltraSwitch™ switch options............................................................................................. 6

6. INSTALLATION................................................................................................. 8
6.1 Wiring instructions.......................................................................................................................... 9
6.2 Cover and housing options............................................................................................................ 10

7. SWITCHES (Certified)........................................................................................ 11
7.1 Installation in hazardous locations................................................................................................. 11
7.2 Adjusting limit switches................................................................................................................. 11
7.3 Cam fine adjustment ..................................................................................................................... 11
7.4 Switch option specifications (all)................................................................................................... 12

8. DIMENSIONS.................................................................................................. 14

9. SPARE PARTS................................................................................................. 15

10. SPECIAL CONDITIONS FOR SAFE USE................................................................... 15

2
FCD AXENIM0135-02 - 09/16

1. GENERAL INFORMATION
WS/WM Ultraswitch™ enclosures provide local and remote position indication for
automated valves. They generally feature a visual black/yellow or red/green indicator for
intuitive local position determination. The WS/WM Ultraswitch™ is available with a number
of limit switch options for remote indication, in a variety of electrical applications. They may
also be used as a junction box for direct installation of solenoid valves.

2. SAFETY INSTRUCTION
Read the safety instructions in this manual carefully before using the product. If any
questions arise during installation, contact supplier/sales office before continuing further.
This equipment is suitable for use in Class 1, Division 1&2, groups ABCDFG or non-hazardous locations
only.

3. UNPACKING
Report transport damage to the carrier immediately. In case of discrepancies - contact your
nearest FLOWSERVE location.

• Substitution of components may impair suitability • Pay attention to personal protection, (clothing,
for Div. 2 locations. glasses, gloves) when performing installation or
service.
• Inspect periodically for degradation. Replace parts if
degradation is found. • All installation, inspection, and maintenance of the
equipment should be performed by suitably trained
• Cleaning this housing by rubbing should be done in personnel. For more information refer to EN 60079-
a non-hazardous area. 14:1997, EN 60079-17, EN 60079-18, EN 60079-19.

• Potential electrostatic charging hazard, clean only • Do not disconnect equipment unless area is known
with a damp cloth – danger of propagating discharge. to be non-hazardous.

• All grounding and bonding installation requirements • To prevent ignition of flammable or combustible
must be addressed. atmospheres, disconnect power before servicing.

• Use only Flowserve original spare parts in order not


to invalidate certification.

WARNING
POTENTIAL ELECTROSTATIC HAZARD
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT
CABLE ENTRANCES MAY REACH A TEMPERATURE OF MAX 83 ºC
SEE MANUAL FOR SAFE USE
CERTIFICATES, MANUAL AND CONTROL DRAWING CAN BE DOWNLOADED FROM
WWW.PMV.NU

3
FCD AXENIM0135-02 - 09/16

4. CERTIFICATES
General Purpose
ATEX II 1GD Ex ia IIC T4/T5/T6
ATEX II 1GD Ex ia IIB T4/T5/T6
cCSAus Class I, Division 1 Groups A,B,C,D; Class II Division 1 Groups F,G; Class III
cCSAus Class I, Division 2, Groups A,B,C,D; Class II, Division 2, Groups F,G; Class III

5. SPECIFICATIONS
5.1 Technical data
Ingress protection IEC 529 IP 66/67, NEMA Type 4X Weight (max) 0.7 kg / 1.55 lbs

5.2 Materials of construction


Part Material
Housings Powder Epoxy painted Aluminum or
PA6/PA66 engineered resin, 25 – 30% fiberglass filled
Covers Powder Epoxy painted Aluminum or
PA6/PA66 engineered resin, 25 – 30% fiberglass filled or
Transparent Polycarbonate
Shaft Stainless Steel SS EN 2346 / AISI 303
Cams/Splines Nylon
Terminal Block Nylon
Internal Brackets Nylon, Aluminum or Stainless Steel
All Internal Fasteners Stainless Steel
All External Fasteners Stainless Steel
All Molded in Fasteners Anodized Aluminum
Indicators Polycarbonate or PA66

5.3 Product label

* NOTE: If the equipment is likely to come in contact with aggressive


substances, it is the responsibility of the user to take suitable precautions
to prevent it from being adversely affected, thus ensuring that the type of
protection provided by the equipment is not compromised.

Product name and model code


Logotype

Approvals Electrical rating


and diagram

Warnings Year of manufacture

Manufacturer Serial number


4
FCD AXENIM0135-02 - 09/16

5.4 WS/WM UltraSwitch™ nomenclature

A = Brand sticker
X Automax
B = Shaft type
N Namur shaft, EN 15714
S Low profile shaft
T For NAF Turnex
D Double ”D” 1/4 Inch Flats
C = Body style
WS General Purpose/I.S. Enclosure / 1/2” NPT Conduit entries
WM General Purpose/I.S. Enclosure / M20x1,5mm Conduit entries
D = Number of conduit entries
2 2 conduit entries
4 4 conduit entries (2 according to ”C” + entries opposite side with different type of th-
reading)
E = Body material
A Aluminum
R Engineered resin
F = Cover material
A Aluminum
R Engineered resin
P Polycarbonate Cover (clear)
G = Indicator
1 No indicator
2 Flat Arrow Indicator Yellow / Black
H Black / Yellow UltraDome™
U Standard UltraDome™ (Red Close/Green Open)
H = Number of switch elements
0 No switches (empty housing)
1 1 Switch
2 2 Switches
I = Switch type - (See page 12 and 13)
J = Certificate
14 General Purpose
15 ATEX Ex ia
28 cCSAus Ni

Ordering code example

A B C C D E F G H I I J J

X N W S 2 A R U 2 P P 2 8

A = brand, NAMUR shaft, 1/2” NPT Housing with 2 conduits, Aluminum body, Resin cover, stadard UltraDome™,
2 proximity switches ”PP”, cCSAus certificate (2 open terminals)

5
FCD AXENIM0135-02 - 09/16

5.5 WS/WM UltraSwitch™ switch options


Cert. Switch Option Manufacturer Load Capacity
M1 SPDT Mechanical Honeywell 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @
MicroSwitch 250VDC; 5A @ 120VAC (resistive load)
MG A, B SPDT Gold Mechanical Honeywell 1A @ 125 VAC; 50 mA @ 24 VDC
MicroSwitch (resistive load)
F1 IN5129 IFM 10-36VDC
F3 IF5250 IFM 10-36VDC NC PNP, 150mA, 3-wire NC
F5 IF6001 IFM 18-32VDC, NO PNP, 150mA@50°C
F6 IF6034 IFM 10-36VDC, NO PNP, 150mA, Stainless
steel
F7 IN0074 IFM 20-250 AC/DC NO, 350mA/100mA
F8 IN0081 IFM 20-250 AC/DC NO, 350mA/100mA w/LED
FJ IN5263 IFM IN-2002-FRKG/PH RT
P4 A, B, C SPST Proximity Aleph 0.35A @ 140 VAC; 0.25A @ 200VDC
(50 W Max.)
P5 A, B, C SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC
(3 W Max.)

PE A, B, C SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 1A @ 24 VDC


PP C SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC
PT A, B, C SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC
N8 A Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor; 8 VDC
NP A Solid State Proximity PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply

NQ A Solid State Proximity PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC


NR Solid State Proximity PF NJ4-12GM40-E1 PNP Sinking; 200 mA max.
Current; 10-60 VDC
NS Solid State Proximity PF NJ4-12GM40-E2 NPN Sourcing; 200 mA max.
Current; 10-60 VDC
NT Solid State Proximity PF NJ4-12GK40-E2 NPN Sourcing; 200 mA max.
Current; 10-60 VDC
N9 Solid State Proximity PF NBB3-V3-Z4 NPN Sourcing; 100 mA max.
Current; 5-60 VDC
NW A Solid State Proximity PF SJ3.5-SN NAMUR NC Sensor; 8 VDC

More switch options available

6
FCD AXENIM0135-02 - 09/16

Code Certificate
A ATEX II 1GD Ex ia IIC T4/T5/T6
ATEX II 1GD Ex ia IIB T4/T5/T6
B cCSAus IS
C cCSAus NI

Notes

1) Valid certification codes according to table in WS/WM Nomenclature on page 5.

2) Some models have more than two open terminal locations open as standard. Consult factory for details.

7
FCD AXENIM0135-02 - 09/16

6. INSTALLATION
The WS/WM Ultraswitch™ may be installed to
valves or valve actuators with a variety of mounting
hardware.

For best results, specify the NAMUR shaft option


and NAMUR mounting hardware when fitting to a
NAMUR compliant actuator. These options allow
direct coupling to actuators without couplings,
reducing dead band.

Bolt bracket to actuator and WS/WM


Ultraswitch™ to bracket, leaving bolts finger tight.

For NAMUR applications the WS/WM Ultraswitch™ ISO/NAMUR


switch shaft features an integral alignment pin. Mounting bracket Hex. screws
This pin must engage the tapped hole in the VDI/VDE 3845 4x M5x8
actuator shaft.

For non-NAMUR applications, make sure to


properly install a coupler between the WS/WM
Ultraswitch™ and actuator. Once the WS/WM
Ultraswitch™ is installed with fasteners loosely
tightened, stroke the actuator two or three times WS/WM switch mounted on rotary actuator
to align the bracket. Then tighten all fasteners.

Ambient temperature working conditions.


The WS/WM Ultraswitch™ switch box is tested
and operational in following temperature range:

-40° – 180°F
-40° – 80°C
Mounting kits
For compact/low profile installation - use mounting kit KL01 or KL02. Use with shaft type ”S” only. These
kits allow the user to install it on actuators with a shaft height of 20, 30 or 50mm. The kits also adapt
easily to both 80/30mm actuator top pattern as well as 130/80mm actuator top pattern (see table below
for reference). Standard NAMUR mounting brackets are also available.
Actuator shaft height (mm)

Bolt pattern 130/30 (mm)


Bolt pattern 80/30 (mm)
Mounting kit p/n

C = Height (mm)

KL01 20/30 yes yes 80/90


Note! Shaft type ”S”
KL02 50 yes yes 110
only!

8
FCD AXENIM0135-02 - 09/16

6.1 Wiring instructions


• Perform all wiring according to the Internal and external grounding
wiring diagram found on the label
in the housing (see picture) and
instructions given below.

• Make sure that the ground wire is


correctly connected

• Seal unused entries with proper and


suitable conduit plugs.

The WS/WM Ultraswitch™ enclosures feature


pre-wired switches. All user connections are made
at a numbered terminal strip. Both external and
internal grounding locations have been provided
for use in installation. A wiring diagram is located Wiring diagram inside
on the product label and indicates which terminal
number corresponds to which switch contact:
normally open, normally closed, common, etc. Terminal strip
Follow the wiring diagram, and electric code to
connect switches to your system.

For field wiring: ensure that any excess wire lengths Caution!
or loops are routed away from any moving parts • Proper and suitable conduit plugs must be
and are short enough, or secured to ensure a 1/4” installed in unused conduit entries before put-
clearance between the wire and the inside surface ting the unit into service.
of the switchbox cover.
• Installation must be according to National
Electric Code, local codes, local certificates
Note: for all magnetically tripped proximity swit- and manufacturer’s instructions in all cases.
ches, the top switch should only be used to indicate Environmental seals must be used to protect
the clockwise position: the bottom switch should ingress of water through the conduits.
only be used to indicate the counter-clockwise
position. Any deviation from these settings may
result in erratic indication. • Prevent electrostatic build-up for safe use. The
enclosure of the WS/WM Ultraswitch™ switch
box is made of PA6/PA66 and any impact or
Solenoids may also be wired through the WS/WM friction caused by external objects should be
Ultraswitch™ enclosure. At least two auxiliary avoided to prevent electrostatic build-up.
terminals are included as standard. Wire the so-
lenoid to auxiliary terminals, then connect power
leads to the opposite terminal side. Be sure to
properly ground the solenoid at the provided
ground terminal.

WS UltraSwitch™ Series enclosures include two


1⁄2” NPT conduit entries and the WM Series inclu-
des two M20x1.5 conduit entries.

9
FCD AXENIM0135-02 - 09/16

6.2 Cover and housing options

Aluminum or Resin Aluminum or Resin Aluminum or Resin


cover cover flat cover
Dome Indicator Arrow Indicator

Polycarbonate transparent cover Polycarbonate transparent cover


Dome Indicator Arrow Indicator

Aluminum housing Resin housing

10
FCD AXENIM0135-02 - 09/16

7. Switches (certified)
Substitution of components may impair suitability for hazardous (classified) locations. Do
not disconnect equipment unless area is known to be non-hazardous.

To prevent ignition of flammable or combustible atmospheres, disconnect power before ser-


vicing, or; read, understand and adhere to the manufacturer’s live maintenance procedures.

7.1 Installation in hazardous locations


Refer to control drawing RA-2. Consult factory.

7.2 Adjusting limit switches


UltraSwitch™ enclosures feature Quick-Set™ cams
which are used to trip the limit switches. These
cams are easily adjusted without tools.

Caution: disconnect power before removing cover


when installed in hazardous locations.

Remove cover and set aside. Rotate actuator/valve
to full clockwise (CW) position. Adjust cam(s) as-
sociated with CW as follows:

1. Push or pull cam against spring to disengage


it from splines.
2. Rotate cam CW breaking contact with switch
(or moving magnet away from switch).
Cam adjustment
3. Continue rotating cam CW just until switch
trips.
rotate cam(s) CCW.
4. Release cam and re-engage it with splines.
Note: factory setting is:
Top switch = CW (closed)
Rotate actuator/valve to full counter-clockwise Second switch = CCW (open)
(CCW) position. Adjust cam(s) associated with
CCW as described in steps 1 through 4, except

7.3 Cam fine adjustment


Some cams have a fine adjustment available. These
cams will have a small screw embedded in the side
of the cam.

Adjusting this screw clockwise or counter clock-


wise will deform the cam, changing the trip point
slightly.

Cam fine adjustment

11
FCD AXENIM0135-02 - 09/16

7.5 Switch option specifications (all)


Code Switch Option Manufacturer Part Number Load Capacity
00 No switches
(empty housing)
F1 IFM IN5129 10-36VDC (J=14only)
F3 IFM IF5250 10-36VDC NC PNP, 150mA, 3-wire NC
F5 IFM IF6001 18-32VDC, NO PNP, 150mA@50°C
F6 IFM IF6034 10-36VDC, NO PNP, 150mA, Stainless Steel
F7 IFM IN0074 20-250 AC/DC NO, 350mA/100mA
F8 IFM IN0081 20-250 AC/DC NO, 350mA/100mA w/LED (J=14)
F9 IFM IN0097 20-250 AC/DC NO FB
IFM IF5249 10-36VDC NO PNP, 150mA, 3-wire NO
FC IFM IF5718 10-36VDC NO PNP/NPN, 150mA, plastic
FE IFM NS5003 IS-2002-N
FG IFM IS5070 FB3004-APKG
FH IFM IS5001 IS-3002-BPOG
FJ IFM IN5263 IN-2002-FRKG/PH RT
FK IFM NS5002 IS-2002-N
FZ AS-i Bus Card 31VDC 28 mA
M1 SPDT Honeywell V7-1C13D8-201 15.1A (1/2 HP) at 125/250 VAC; 1/4A at 125 VDC;
Mechanical MicroSwitch 1/4A at 250 VDC; 5A at 120 VAC (resistive load)
MG SPDT Honeywell V7-1D19D8-201 1A at 125 VAC / 50 mA at 24 VDC
Gold Mechanical MicroSwitch (resistive load)
N1 Pepperl+Fuchs NJ4-12GM40-E
N2 Pepperl+Fuchs NJ2-12GK-N
N3 Pepperl+Fuchs SJ3,5-S1N
N4 Pepperl+Fuchs NJ2-12GK-SN
N5 Pepperl+Fuchs NJ4-12GK40-E
N6 Pepperl+Fuchs NJ4-12GK40-E1
N7 Pepperl+Fuchs NBB2-V3-E0
N8 Solid State Proximity Pepperl+Fuchs NJ2-V3-N NAMUR Sensor Output / 5-25 VDC Supply
N9 Solid State Proximity Pepperl+Fuchs NBB3-V3-Z4 NPN Sourcing/ 100 mA max. Current / 5-60 VDC
NA Pepperl+Fuchs NBN4-12GM40-E2
NB Pepperl+Fuchs NJ2-12GM-N
NC Pepperl+Fuchs NJ4-12GM-N
ND Pepperl+Fuchs NCB2-12GM40-Z1
NE Pepperl+Fuchs NCB2-12GM35-N0
NF Pepperl+Fuchs NCN4-12GM35-N0
NG Pepperl+Fuchs NJ5-11-N-G
NH Pepperl+Fuchs NCB4-12GM40-N0
NK Pepperl+Fuchs NCN4-12GM40-Z0
NL Pepperl+Fuchs NCB2-V3-N0
NM Pepperl+Fuchs NJ2-11-SN-G
NN Pepperl+Fuchs NBB2-V3-E2
NP Solid State Proximity Pepperl+Fuchs SJ3.5-N
NQ Solid State Proximity Pepperl+Fuchs NJ4-12GK-N
NR Solid State Proximity Pepperl+Fuchs NJ4-12GM40-E1 PNP Sinking / 200 mA max. Current / 10-60 VDC

12
FCD AXENIM0135-02 - 09/16

7.5 Switch option specifications (continued)


Code Switch Option Manufacturer Part Number Load Capacity
NS Solid State Proximity Pepperl+Fuchs NJ4-12GM40-E2 NPN Sourcing / 200 mA max.
Current / 10-60 VDC
NT Solid State Proximity Pepperl+Fuchs NJ4-12GK40-E2 NPN Sourcing / 200 mA max.
Current / 10-60 VDC
NV Solid State Proximity Pepperl+Fuchs NJ2-11-N-G NAMUR Sensor Output / 5-25 VDC Supply
NW Solid State Proximity Pepperl+Fuchs SJ3,5-SN NAMUR Sensor Output / 5-25 VDC Supply
NX NBB2-V3-E3
NY Solid State Proximity Pepperl+Fuchs NJ4-12GK-SN NAMUR Sensor Output / 5-25 VDC Supply
P4 SPST Proximity Aleph PS-6132 0.35A at 140 VAC / .25A at 200VDC
(50 W Max.)
P5 SPDT Proximity Hamlin 59135-030 0.25A at 120 VAC / 0.25A at 28 VDC (3 W Max.)
PE SPDT Sabre Pxy Flowserve XA0199 1A at 120 VAC / 1A at 24 VDC
PP SPDT Phazer Pxy Flowserve XA0155 3A at 120 VAC / 2A at 24 VDC
PT SPST BRS Pxy Flowserve XA0157 3A at 120 VAC / 0.5 at 24 VDC
R1 Pepperl+Fuchs NBB3-V3-Z4-3G-3D
R2 Pepperl+Fuchs NBB2-V3-E3-3G-3D
R3 Pepperl+Fuchs NBN4-V3-E2-3G-3D

13
FCD AXENIM0135-02 - 09/16

8. Dimensions

WS body enclosure WM body enclosure

14
FCD AXENIM0135-02 - 09/16

9. Spare parts

1 Pos Part No Description

1 D2-SP31 Arrow indicator assembly

2 D2-SP52 Dome indicator assembly


red/green
2 2 D2-SP17 Dome indicator assembly
black/yellow

3 M800214 Polycarbonate transparent cover


with dome indicator red/green

4 M800215 Polycarbonate transparent cover


with arrow indicator
3 5 ME1967 Gasket for cover
(all cover types)

10. Special Conditions for Safe Use

• The Rotary Limit Switch Box is marked with the following warning marking: ”WARNING – POTENTIAL
ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS”.

• Enclosure material limits for EPL Ga are exceeded, as aluminium content is greater than 10%. User
must determine the suitability of the equipment for the particular application, for example, to avoid an
ignition hazard due to impact or friction

• The total electrical ratings must not exceed the values indicated in the control drawing, W-43C.

15
Flowserve Corporation
Flow Control Division
1978 Foreman Drive
Cookeville, Tennessee 38501 USA
Phone: +931 432 4021
Fax: +931 432 5518

Flowserve Flow Control (UK) Ltd.


44 Victoria Way, Burgess Hill
West Sussex, RH15 9NF
UNITED KINGDOM
Tel: +44 (0) 1444 884846
E-mail: pmvuksales@flowserve.com
Country Name
Flowserve
Town Name, Flow Control
City 00000 Benelux
Country
Rechtzaad 17
Telephone: 0 000
4703 RC Roosendaal000 0000
THE NETHERLANDS
Country Name
Tel: +31 (0) 30 6771946
Town Name,
Fax: +27 (0)City 00000 Country
30 6772471
Telephone: 0 000 000 0000
E-mail: fcbinfo@flowserve.com

Country
FlowserveName
Flow Control GmbH
Town Name, City
Rudolf-Plank 000002Country
Strasse
D-76275 Ettlingen
Telephone: 0 000 000 0000
GERMANY
Country
Tel: +49 Name
(0) 7243 103 0
Fax: +49
Town (0)City
Name, 7243 103 Country
00000 222
This area can be used for divisional information E-mail: argus@flowserve.com
Telephone: 0 000 000 0000
Flowserve
Country NameSpa
Via Prealpi, 30
Town Name, City 00000 Country
20032 Cormano (Milano)
Telephone:
ITALY 0 000 000 0000
Tel: +39 (0) 2 663 251
Country Name
Fax: +39 (0) 2 615 18 63
Town Name,
E-mail: City 00000 Country
infoitaly@flowserve.com
To find your local Flowserve representative:
Telephone: 0 000 000 0000
Flowserve Ahaus GmbH
To find your local Flowserve representative please use the Sales Country Name 19a
von-Braun-Str.
Support Locator System found at www.flowserve.com 48683
Town Ahaus
Name, City 00000 Country
Phone: +49 2561000
Telephone: 0 000 686-119
0000
Fax: +49 2561 686-109
FCD AXENIM0135-02 - 09/16 Country Name
Flowserve
Town Name, Corporation
City 00000 Country
Bulletin XX-00-00 (X) No. 35, Baiyu Road
Telephone: 0 000 000
Suzhou Industrial 0000
Park
Suzhou 215021, Jiangsu Province,
Country Name
Flowserve
To find Corporation
your local hasFlowserve
established industry leadership in the design and manufacture
representative: PRC
of its products. When properly selected, this Flowserve product is designed to perform its Town Name,
Phone: City 00000 Country
+86-512-6288-1688
intended function safely during its useful life. However, the purchaser or user of Flowserve Telephone: 0 000 000 0000
Fax: +86-512-6288-8737
products
To findshould
yourbelocal
awareFlowserve
that Flowserve products mightplease
representative be useduse
in numerous applications
under a wide variety of industrial service conditions. Although Flowserve can provide general Country Name
the Sales
guidelines, Support
it cannot Locator
provide System
specific data andfound at for all possible applications. The
warnings Flowserve Australia Pty Ltd
purchaser/user must therefore assume the ultimate responsibility for the proper sizing and Town
Flow Name,
ControlCity 00000 Country
Division
www.flowserve.com 14 Dalmore Drive
selection, installation, operation, and maintenance of Flowserve products. The purchaser/user Telephone: 0 000 000 0000
should read and understand the (WS/WM Switchbox User Instructions) instructions included Scoresby, Victoria 3179
withOrthecall
product, and train
toll free: its employees
0 000 000 and contractors in the safe use of Flowserve products Austrialia
Country Name
in connection with the specific application. Phone: +61 City
3 9759 3300
Town Name, 00000 Country
Fax: +61 3 9759 3301
While the information and specifications contained in this literature are believed to be accurate, Telephone: 0 000 000 0000
they are supplied for informative purposes only and should not be considered certified or
as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be Flowserve
Country Pte Ltd
Name
construed as a warranty or guarantee, express or implied, regarding any matter with respect No. 12 Tuas Avenue 20
Town Name, City 00000 Country
to this product. Because Flowserve is continually improving and upgrading its product design, Singapore 638824
the specifications,
Flowserve Corporation hasdimensions andleadership
established industry information contained
in the design hereinofare
and manufacture subjectWhen
its products. to change without
properly selected, this Flowserve Telephone:
Phone: +650 000
6879000 0000
8900
notice. Should any question arise concerning these provisions, the purchaser/user should
product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware
that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can provide Fax: +65 6862 4940
contact Flowserve
general guidelines, Corporation
it cannot provide specificat any
data and one
warningsof for
itsallworldwide operations
possible applications. or offices.
The purchaser/user must therefore assume the ultimate Country Name
responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and
understand the (INSERT OFFICIAL USER INSTRUCTION TITLE) instructions included with the product, and train its employees and contractors in the Town Name, do
Flowserve CityBrasil
00000Ltda
Country
For
safemore information
use of Flowserve productsabout Flowserve
in connection Corporation,
with the specific application. contact www.flowserve.com or call USA
1-800-225-6989. Rua Tocantins,
Telephone: 0 000128
000 -0000
Bairro Nova
While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and
should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a
Gerti
©warranty
October 2013, express
or guarantee, Flowserve Corporation,
or implied, Irving,
regarding any matter Texasto this product. Because Flowserve is continually improving and upgrading
with respect São Caetano do Sul,
its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise
concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. São Paulo 09580-130 Brazil
Phone: +5511 4231 6300
For more information about Flowserve Corporation, contact www.flowserve.com or call USA 1-800-225-6989.
Fax: +5511 4231 6329 - 423

flowserve.com