Brosur Katalog Fire Alarm HOOSEKI

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Convensional

Semi Addressable
Full Addressable
ADDRESSABLE FIRE ALARM CONTROL PANEL CONVENTIONAL FIRE ALARM CONTROL PANEL
FEATURES
FEATURES Two-Stage alarm delay function :
At the first stage, when the detector sends the signal for the first time, the control
English LCD Screen (240 x 128 or 240 character).
LCD backlight energy-saving protection function. panel will automatically reset the signal and enter the second stage for standby
Two-wire circuits for supper long transmission distance after 8 seconds.
(up to 1,5 km between the control panel and modules). At the second stage, if there is another signal sent by the detectors within 9-40
The data memory device can store up to 2000 historical records permanently seconds, the control panel will triggered the fire alarm, else reset the alarm signal.
(the device in graphic system can be expandable up to 20 million records). This will prevent the control panel from sending false alarms.
Composed voice alarm function (broadcost)in human voice to operators). Standby battery protection :
Voice guidance function (while operating) During power-cut, when the standby battery is under DC 18V it will automatically
Abnormal temperature protection function (I/O modules over loading).
stop discharging to extend battery life.
5LCs, IDCs are equipped with insulation for false inspection function.
Protection against lighting surge :
Protection against lightning surge. HOOSEKI Fire Alarm
I/O modules miswiring protection to accessories are available. Power supply module with protection against lightning surge to avoid device
Control Panel
I/O modules are equipped with segment isolation function. damage caused by high voltage or power surge.
A table to review all I/O modules statuses is available for casier operation. Quality control :
Addresses and interlocks can be display on the LCD screen. All interior components of the display module and base boards in the unit are
Weekly automatic check function. approved by CE and CNS. All products have to pass strict inspection before
Repeat alarm function. delivery to ensure durability.
Two stage alarm delay function
Abnormal voltage inspection :
Standby battery with power saving function HOOSEKI Fire Alarm
With abnormal voltage display function, the system can indicate high and low voltage.
Build in-printer Control Panel
Modular design :
The system has modular design with inputs/ outputs independet terminal module. If there is a problem on site, users do not have
to remove external wires and can easly replace defective boards improving the efficiency of maintenance and inspection.
HOOSEKI Fire Alarm Annunciator Exterior design :
Equipped with zone display panel board. The panel (made of flame retardant plastic) adopt a streamline design for clear
DIMENSIONS (STEEL) *Size mark in red represent with printer aption. indication of zone’s name, floor, building, properties, etc.
Cabinet Wall-mount Other Functions:
Can be integrated with the TYY Voice Evacuation System and the Emergency Telephone System in one cabinet for more
Addressas appealing look and less space consuming.
/Loops 255/1L
255/1L
510/2L 765/3L 1020/4L 1275/5L 1530/6L 1785/7L 2040/8L
DIMENSIONS (STEEL)
H(mm) 450 500 840 1020 Cabinet Wall-mount
Number
of Loops 5~10L 15L 20L 25~30L 35~40L 45~50L 55~60L 65~70L 75~80L 85~90L 95~100L 105~110L 115~120L
W(mm) 480 480 480 480 H(mm) 400 495 580 520 580 700 760 840 930 1020 1110 1195 1350
W(mm) 300 300 300 480 480 480 480 480 480 580 580 580 580
D(mm) 130 (*160) 160 180 180
D(mm) 120 120 120 180 180 180 180 200 200 200 200 200 200
Interlock
SPECIFICATIONS Cabinet Floor-standing 2-in-1 3-in-1 4-in-1 Control Panel
Number 125~130L 135~150L 155~170L 135~260L 265~300L 305~340L 345~450L 455~600L 1L 1L
of Loops
ITEM Specifications H(mm) 1600 1800 2000 1600 1800 2000 1800 1800 180 250
W(mm) 580 580 580 1160 1160 1160 1740 2320 180 210
Model HS-ADD-1P/8L(1Loop/8Loop), HS-ADD-AN1/8 (1 Loop/8 Loop)
Power Source 110V AC 50/60 Hz or 220V AC 50/60 Hz D(mm) 260/360 260/360 260/360 260/360 260/360 260/360 260/360 260/360 75 90
Addresses / Loops 128/1L 256/1L 512/2L 768/3L 1024/4L 1280/5L 1536/6L 1792/7L 2048/8L
Standby Battery 24V DC SPECIFICATIONS
Transmission Distance Two-wires (able for branch wiring 1,5km
ITEM Specifications
Annunciator Use RS-485 for 800m, Network Signal Transceiver for 3km and Optical Fiber
Connection for up to 40km Model HS-5L, 10L, 15L, 20L, HS-25L, 30L, 40L, 50L (5 Zone - 40 Zone)
AN-5L, 10L, 15L, 20L, 25L, 30L, 40L, 50L (5 Zone - 50 Zone)
Loop Voltage Load Power / Indicating Lamp / Zone Telephone : 24V DC Power Source 110V AC 50/60 Hz or 220V AC 50/60 Hz
SLC power source: 32V AC Standby Battery 24V DC
Power Consumption Main control panel (monitoring) : 500mA Charging Voltage Below 26V DC 450mA, trickle charging
Circuit Voltage 24V DC operation voltage, under 10~11V DC 32mA
Communication module for each system (monitoring): 280 mA Rated Impedance Under 50 , Ground Resistance above 2M
Transmission Method Selective and sequential (I/O modules) Detector Connection No limiitation for Conventional Rate of Rise Heat / Fixed Temperature Heat
Detectors : Up to 30 Photoelectric Smoke Detectors (24V DC 40 A) per zone
Broadcast Output Relay output : interlock relay board x 13 sets for a max of 2,000 contacts E.O.L Resistor 10K
Method (relay board = 40 contacts [standard], 160 contacts [expansion]) No. of Indicators 1.2 times of the number of zone (LED indicating lamp)
Main Audio Voice notifications, human voice or voice alarm (over 90 dB) No. of Bells 1.2 times of the number of zone
o Color Green/ Red / Black
Ambient Temperature 0~40 C Buttons Rocker Switch / Push-button / Capacitive Touch Switch
Cabinet Material Powder coating steel (optional Flame retardant ABS enclosure available Cabinet Material Powder coating steel (optional Flame retardant ABS enclosure available
up to 256/1L only) up to 20L only HOOSEKI Fire Alarm
Main Audio Mono tone sounder (above 85dB for 1m distance) Annunciator
Alarm Relay Contact 2 sets of No-Voltage NO contact, capacity AC 250V / 7A
FIRE ALARM SYSTEM FIRE ALARM SYSTEM
&ŝƌĞůĂƌŵW͘͘>ŽŵďŝŶĂƟŽŶ^ĞƌŝĞƐ Fire Alarm Accesories
Base Manual
Call Point (HS-Base) FRONT VIEW HS-PBL
DESCRIPTION SIDE VIEW Fire Alarm Combination
This Fire Manual Station can quickly transmit a signal to the fire
receiver terminals or the repeaters while the button under a
TOP VIEW DESCRIPTION
transparent protective cover has been pushed at the first finding
Material Plate MS tebal 1.2 mm
of a fire accident. (This signal is beyond the accumulated time
Engsel SH-006
limitation).
There is a light over the button. The light will light up as a signal has been exactly Mata ayam

received by the receiver terminal. There is also a telephone jack for telephone Knob pintu

communication with attendant at the fire receiver terminal. Telephone


Te
HS-FP1 Manual Call Point
ADVANTAGES Handset
SPESIFICATIONS 1. Auto-Return by pushing button, no need to disassemble
Material ABS Plastic
Model No. HS-FP1 the main body. Purpose Equipped in Fire Hose,
Voltage Range 24V DC 2. Response light available to identify the operation completed. insert to manual call point
Alarm Current 30 mA
3. Reinforced transparent protective cover is reusable. plug for communicating with
Contact Rating 24V DC 100mA
4. All plastics are fire-proof, light, convenient and stylish. fire alarm control panel
Sub-Function Phone jack; Confirmation LED;
Dimensions 212 (H) x 63 (W) x 50 (D) mm
Reset button 5. Outside cord distribution with terminators to ease on work.
Option Base
Material Fire-Proof plastics MOUNTING
Dimensions O 140 (mm)
Weight 150g
Color Red
28 70

BOX Main Distribusion Frame FRONT VIEW SIDE VIEW


HS-FL3 Indicator Lamp LED
17 51
(MDF) DESCRIPTION
Material Plate MS
TOP VIEW tebal 1.2 mm
Engsel SH-006
Kunci Hubben
SPESIFICATIONS
50 pairs
Model No. HS-FL3
: 50 x 40 x 13 cm
Power Source 24V DC
Alarm Current 12 mA
DESCRIPTION Ambient Temp. -10 C~+55 C
The fire indicating lamp is an equipment to go twinkling, Material Fire-Proof plastics
to show the position of a fire signal device and to be Weight 52g
controlled vby fire receiver terminal or a repeater while
Dimensions O 92 x 58 (H) mm
Color Red
a fire accident accured.

HS-FB6 Alarm Bell FB6 24V


DESCRIPTION ADVANTAGES
The fire alarm bell is an equipment 1. The way of motor-driven is taken at the low consumption
controlled by the fire receiver of current, to reduce the load for power output from
terminal or the repeater and sounds receiver terminal. BOX TB (Terminal Box) 12 pairs, 24 pairs
a warning as a fire accident occured. 2. This design of exceptional structure is sturdy and durable.
The bell even can ring to last 40 hours without decline of DESCRIPTION
SPESIFICATIONS the performance and structure. Material Plate MS tebal 1.2 mm
Model No. HS-FB6 Engsel SH-006
Fire Alarm
Power Source 24V DC Main Control Board Kunci Hubben
Alarm Current 35 mA Zone Alarm
12 pairs : 30 x 20 x 8 cm
Movement Motor + + + + 24 pairs : 30 x 25 x 8 cm
Material 3.0 Alloy Alu B B B
Dimensions O 6” (150mm) - - - -

Weight 418g Common


Sound Output 90 dB/ M and above Wiring

Color Red
FIRE ALARM SYSTEM FIRE ALARM SYSTEM
I/O Modules I/O Modules
Control Modules
Isolation Module 1 In 1 Out
Control Modules 1 In 1 Out (with isolation function)
FUNCTIONS Coomunication isolation function, when short circuit occurred in the module, the
Isolation module for addressable 2 wire communication module will be automatically isolated from the main communication line.
Module Base
(IN) (OUT) system
S+ S- S+ S- Recoomend to use for each 25 addressable equipments FEATURES
Isolation short circuit indicating lamp
Bult-in tri-state LED indicator to indicate different
Not occupy address
statuses, “Monitoring”, “Disconnection”, and
INPUT OUTPUT Deploy at main line for branching purpose
“Fire State”. HS-ADD-I/O-1
HS-ADD-IM SLC Contact SLC Contact Isolation module deploys between main line and branch
SPECIFICATIONS
Binary coded address dip switch
line, when short circuit happens, isolation module will
Two-wire multi-transmission
auto-isolate the error part with the main line so can avoid EOL : Below 10K capacitor / address.
Stable communication with resistance to noise
the whole zone break-down Operating Environment : 0 C- 50 C relative
and disturbances
Alumina rail lock strukture, easy to install humidity below 85%
Self-test function for circuit disconnection and
Monitoring Current : 420 A
activation
Activating Current : 16mA
SPESIFICATIONS Expandable to connect with photoelectric
Load Voltage Input : 24V DC (YRR-02)
smoke, rate of rise heat and fixed temperature
Function Communication short circuit isolation Rated Voltage : 33V AC
Operating Voltage DC16~36V heat detectors
Output Contact Capacity : 30V DC / 2A (max)
Current Consumption DC32V normal 400 A LED indication pattern, as follows :
Material : Flame retardant plastic
Reaction time Below 0.3 sec monitoring (flash at intervals of 2.5s),
Ambient Temperature 0 C~50 C Relative Humidity below 95%
Dimensions : 80 (H) x 60 (W) x 30 (D) mm
disconnection (flash at intervals 0.5s) and fire
Dimension 67 x 100 x 26 mm Note : EOL capacitor
state (on)
Material Fire~proof plastic
Can be fixed on alumunium railings for easy
installment

Base Detectors Addressable SPESIFICATIONS


(Only for Full Addressable System) Function Circuit Input
EOL Resistor Bellow 10 /master line
HS-ADD-BD Ambient Temperature -10 C~50 C Relative Humidity below 95%
Suitable for Model: Monitored Current 420 A/DC24V FEATURES Control Modules
Operating Voltage DC16~30V
- ROR (HS-WS19L)
Material Fire-proof plastic
Built-in tri-state LED indicator to indicate 4 In 4 Out
- Fixed (HS-WK100L) Dimension 108 x 22.6 mm different statuses, “Monitoring”, “Disconnec-
- Smoke (HS-WT30L) Note Addressable profesional EOL resistor tion” and “Fire State”
Binary coded address dip switch HS-ADD-I/O-4
Two-wire multi-transmission
SPECIFICATIONS
WIRING APPLICATION & INSTRUCTION Stable communication with resistance to noice EOL : Below 10K capacitor / address.
FUNCTIONS Operating Environment : 0 C- 50 C relative
and disturbances
Status indicators for “Monitoring, ”Active,”Er- humidity below 85%
Self-test function for circuit disconnection and
ror” and “Isolating.” Monitoring Current : 3.2 mA
activation
Address coding by binary coded dip switch Activating Current : 48mA
Expandable to connect with photoelectric
for easier setting Activating Current : 64mA (YRR-4L & YRR-4LO)
smoke, rate of rise heat and fixed temperature
Two-wires multi multi-transmission Load Voltage Input : 24V DC (YRR-3LO & YRR-4LO)
heat detectors
Stable communication with rejection to noise Rated Voltage : 33V AC
LED indication pattern, as follows :
and disturbances Output Contact Capacity : 30V DC / 2A
monitoring (flash at intervals of 2.5s),
Self-test functions for circuit disconnection (YRR-3LO & YRR-4LO)
disconnection (flash at intervals of 0.5s) and fire
and activation Material : Flame retardant plastic
state (on)
Expandable to connect with photoelectric Dimensions : 87 (H) x 93.5 (W) x 43 (D) mm
Can be fixed on alumunium railings for easy
smoke, rate of rise heat and fixed tempera- Note : EOL capacitor
installment
ture heat detectors , and no need for ex-
ternal power supply

Wiring Notes :
Addressable Detector Base’s L+ LC connect
to Convensional Detectors’ L+ LC, polarized
Provided current is not over 1.3mA/DC24V
A Profesional terminal device is needed,
cannot use a normal 10K
FIRE ALARM SYSTEM FIRE ALARM SYSTEM
Rate of Rise Heat Detector Fixed Temperature Heat Detector

ISO 9001 certificated


DESCRIPTION
The rate-of-rise heat detector, HS-WS19L, is designed ISO 9001 certificated
to sense the rapid or abnormal rise in temperature of
air. If ambient temperature rises rapidly, the air in DESCRIPTION
chamber expands and presses the diaphram to close
The detector, HS-WK100L incorportes a self-resetting
the contact point to give advanced warning. When
bimetallic disk element with response indicator.
a slower temperature change occurs, the expanded
It activates whenever the ambient air temperature
air escapes through a bleeding hole to keep the HS-WK100L
reaches the top temperature detector setting.
HS-WL19L pressure balanced so that the fault alarm
never occurs.
ADVANTAGES
ADVANTAGES Stabilized performance, long-term durability and Red indication lamp lights when detector is activated.
Rate-of-rise heat detector detects intense fires by Red indication lamp lights when detector is least-malfunction are ensured by employing a High-temperature-enduring plastics are used to build
quickly responding to rapid temperature increases. activated. bimetal mechanism. up the main body which is also nicely shaped.
Mechanical operating principles ensure the long- High-temperature-enduring plastics and fire-proof Self-restoring ensures the elements repeated use. The base is in common with other detectors made
term durability and the least malfunction. material are used to build up the main body of The sensitive part is enclosed to prevent from in this company for the facilitation of installation.
Self-restoring ensures those elements repeated use. the detector. being moistened and contaminated. Connections are non-polarized to avoid wiring
High quality components are fitted for greater The base is in common with other detectors made Pure silver contacts ensure the quick response. mistakes.
reliability. in this company for the facilitation of installation.
Coonections are non-polarized to avoid wiring
mistakes.
SPECIFICATION
SPECIFICATION
Main Model HS-WK100L Alarm Temperature Comply to EN54, CNS
Model HS-WS19L Ambient Temp. -10 C~+55 C Type 2 wire Ambient Temperature -10oC~+55oC
Type 2 wire Ambient Humidity 0~95% Voltage Range 12~30V DC Ambient Humidity 0~95%
Voltage Range 12~30V DC Material Fire-proff Plastics Alarm Current 24V DC 30mA Material Fire-Proof plastics
Alarm Current 24V DC 30mA Dimensions 102 (Dia.) x 42 (H)mm Polarization Non-polarized Dimensions 101 (Dia.) x 47 (H)mm
Contact Rating N/A Weight 130g Fixed Temperature 60 C, 70 C, 80 C. Weight 100gms.
Polarization Non-polarized Color White Sensitivity : Color White
Alarm Temp. Comply to EN54, CNS
When exposed within an air stream 1 m/sec., 125%
+ higher than its operating temperature, and at 20 C
OPERATION PRINCIPLES of ambient temperature, the detector will sound an
alarm within 90 seconds.

Contacting Point
- OPERATION
Insulator Leak Hole MOUNTING STATUS PRINCIPLES
Thermostat Terminal

Diaphragm
Heat-Detecting Chamber
MOUNTING STATUS
DIMENSIONS
Base
Unit: mm 42 83 Heat-Detecting Plate
Body Pitch
Contacting Point Circular Disk Bi-Metal

90 Cap 83
Insulated Pin
Pitch
102 Base
WIRING AND CONNECTION
46

WIRING AND CONNECTION


Head

46
O 90

O 103
O 103
FIRE ALARM SYSTEM
Photoelectric Type Smoke Detector HS-WT30L
ISO 9001, Approved
DESCRIPTION
The photoelectric type smoke detector is based on the
photoelectric sensing principle to make up.
When fire break out and smoke enters the light- tight
box, the particles of smoke scatter the infrared light,
and this scattered light goes into the receiving element,
thereby emitting an electric current, and while the
electric current is up to the fixed extend, the fire alarm
will be activated. This is an advance scientific device. It
is very quick and accurate to activate the early fire
HS-WT30L warning system. Because of the pretty and compact
styling, it is most suitable for the interior decoration of the
modern buildings.

MOUNTING STATUS
SPECIFICATION
Unit: mm
Main Model: HS-WT30L
Series Model: HS-WT30L1. HS-WT30L3
83
Rated Voltage: 24V DC
Pitch
Working Voltage: 12V to 30V DC
Standby current: 60 micro amps.(max)
Base
Alarm Current:1OOmilli amps.(max)
Initial Stabilizing Time: 15sec Body

46
Identification Light: Red color(LED).
Ambient Temperature: -10 C~+50 C
Ambient Humidity: 0-95%
O 103
Body Case: Fire-Proof Plastic
Weight: Approx.140g.
Color: Creamy-white. WIRING AND CONNECTION
Used Conventional

Remote Indikator Lamp HS-R1L


Detector Status LED Indicator :-
Alarm Status : Red
80 mm

HS-R1L
60 mm
SPECIFICATIONS
Technical Specifications Smoke Detectors
Normal Rated Voltage 1,5 - 5 VDC
Operating Voltage 1.5 VDC
Alarm Current 20mA
Weight 30g