1. Basic Specification
Item Specification
Controlled axis Simultaneous 6 axes (maximum 8 axes as option)
Servo motor AC servo motor
Position reader Absolute encoder
Programming language Teaching playback
Program number 9,999 programs
Memory capacity 256MB (2,560,000 steps equivalent)
5.7 inches color LCD (640*480, with back light, 65,536 color display)
standard cable length 8m (direct inlet specification)
Teach pedant
single hand 3 position enable switch (left hand), touch panel,
IP65 equivalent, Weight 0.96Kg, Cable diameter φ8.3mm
Mode select switch (teach/playback), Emergency stop button,
Operating panel
Motor ON button, Start button, Stop button
Safety function PLd (category 3)
Cables to robot standard cable length 5m (direct inlet specification)
Memory device Flash memory
External memory device USB memory (USB memory itself is not accessory of controller)
Interface panel on front door inside, side panel and rear panel (refer to
User interface another sheet) (When hardware option is added, some place may not
be available to use.)
Construction Full closed cabinet
Dust proof, drip proof IP54 equivalent
Cooling Indirect cooling method
AC200V – 220V +/- 10% (3 phase, 50/60Hz) D grounding
Main circuit breaker 40A, Leak current maximum 100mA
<Consuming power>
Primary power supply While robot’s moving : Refer to the specification sheet for each robot
While power saving : 0.13kVA (cooling fan is activating),
0.08kVA (cooling fan is stopping)
In power saving, motor power is turned off and robot arm is held by brake.
2. Control Specification
Functions Abstract
Machine lock This can check I/O by playback program, keeping robot stationary.
This can check program flow by changing logical I/O from teach pendant,
I/O simulation
keeping physical I/O locked.
This can protect program to avoid the modification and deletion by careless
Memory protect
operation.
This can save energy by motor power off and brake lock after
Power saver pre-determined time passed with no movement. When more time passed,
fan motors inside of cabinet will stop for further power saving.
Real time monitor of following data;
1. Robot program
2. Error logging
3. Fixed I/O
Monitor utility
4. General usage I/O
5. Program queue
6. Operating time
7. PLC program (ladder monitor), and or so
Help message Operations and function explanations are displayed on teach pendant.
(Built-in manual) And graphical troubleshooting manual is also displayed.
Customization Software keys are re-locatable for better operation.
When main power is down while playback robot, all necessary data is back
Power failure backup
upped for easy restarting of the robot after power on.
Program queue Up to 10 programs to be played back can be reserved.
Home position Up to 32 home position can be defined. Home position signal is outputted.
- General usage signal output
- General usage signal input
Functions - Program flow control (step jump/call, program jump/call)
- Timer delay
- Welding, and or so
Pushbuttons and lamps can be arranged on teach pendant touch panel
screen. Operating switches and indicators are replaced to software, so this
Interface panel
utility can contribute to cost down.
Available to register up to 31 keys /screen * 8 screens = 248 keys
Ethernet File upload and download via Ethernet is available. (1 port)
Serial interface RS232C communication is available. (1 ch)
This is software programmable logic controller.
Built-in PLC Physical I/O board (another option) is necessary to perform I/O
actually.(Refer to hardware option)
In the case operation mistake or unexpected interference occurs during
High Speed
teaching work, this function can detect it as a contact with outside world,
Interference Detection
and stops the robot immediately.
This is to prevent from trouble occurrence by estimating the lifespan of
Overhaul Prediction bearings in each robot arm and by detecting torque over.
Furthermore, this function can predict the overhaul timing of robot.
Page-5
(*1) Additional box for transformer is necessary on the standard cabinet. External dimension of controller
is changed to W580*D542*H1180 mm (not including the height of stand 60mm).
Page-6
Others
Vision system can see the target such as work-piece by camera, and
Built-in vision
1 measure its position. Control unit is stored inside of controller.
sensor *2
[FD11-OP139-A〕
Analogue I/O interface board is added.
Analogue I/O Input 2ch (-10 to +10V) / Output 4ch (-10 to +10V)
2
*1
[AX10-OP46-A(analog input),-B(analog output)]
To perform conveyor synchronized motion, speed signal receiver board
is added.
[FD11-OP47-A]
Conveyor Specification of receiver board:
3
synchronization *1 Differential input(conforming to RS-422), Terminating register 100Ω
(can be set by SW on board), Response frequency 1MHz max
NACHI prepares the conveyor pulse transmitter unit also.
[AW10-OP47-A]
Main circuit breaker is replaced to the leakage detection type (Sensitivity
Leakage detection
4 current 100mA).
circuit breaker *3
[FD11-OP106-A(200V),-B(400V)]
Portable brake release switch.
Also fixed type switch (mounted inside of cabinet) is prepared.
5 Brake release SW
[FD11-OP90-D(in the cabinet),-E(unit type, cable length 5m),
-F(on the door)]
Controller primary power can be switched ON/OFF by the signal from
External power
6 external device.
ON/OFF control
[FD11-OP18-A]
Operating panel on cabinet is removed and mounted on separate box.
Separate
7 Cable length :5m, 10m, 15m, 20m
operation box
[FD11-OP64-A-C05,-C10,-C15, -C20]
Regenerative discharge resistor is upgraded for high duty motion such as
Upgrading of
palletizing.
8 regenerative
[FD11-OP65-B, -C(High-duty specification)]
discharge resistor
If the robot is LP-series, FD11-OP65-C is installed.
By using an external signal instead of the mode selection switch on the
operation panel, the operation mode can be selected. When this option is
External mode
9 installed, the operation panel is removed from the controller and cannot be
selection
used.
[FD11-OP20-A]
A Robot Monitoring Unit (RMU20) that monitors the robot position and the
Robot Monitoring robot speed is added. In this option, an exclusive IPM drive unit is
10
Unit (RMU20) necessary.
[FD11-OP145-A]
*1: Extension PCI slot in PCB rack is allocated to this. 3 PCI slots are prepared.
*2: This utility occupies the standard Ethernet port on CPU board.
So if Ethernet utility is necessary, another Ethernet option [FD11-OP83-A] is necessary.
Furthermore, servo ON/OFF control of mechanism by mechanism [FD11-OP80-C] (2 axes at the
same time) can not been used.
*3: If leakage detection circuit breaker is prepared by customer at the primary power supply, its sensitivity current should be
100mA or higher.
*4: 8 axes additional option [FD11-OP124-A (transformer spec.), FD11-OP124-C (transformer-less spec.)] is necessary.
<NOTES> Combination of options
・ Built-in vision sensor [FD11-OP139-A] and External power ON/OFF control [FD11-OP18-A] can not been used at the same
time.
・ Built-in vision sensor [FD11-OP139-A] and Servo ON/OFF control of mechanism by mechanism [FD11-OP80-A,-B,-C] can not
been used at the same time.
・ In case of CE specification, Brake release SW in the cabinet [FD11-OP90-D] can not been used. Please select Brake release
SW on the door [FD11-OP90-F].
・ When using "External power ON/OFF control" [FD11-OP18-A] and "8 axes additional option" at the same time, 8 axes
additional option [FD11-OP124-D (transformer spec.), FD11-OP124-E (transformer-less spec.)] is necessary.
・ The "Robot Monitoring Unit" [FD11-OP145-A] and the "Built-in vision sensor" [FD11-OP139-A] cannot be used at the same
time. And, "2 axes" of "Mechanism by mechanism servo ON/OFF" [FD11-OP80-C] is also unavailable with this option.
Page-8
3. Controller Appearance
3.1 Controller dimensions
Page-10
Operation panel
Teach pendant
TP selector 175mm
switch
Emergency stop
button
Sheet key
Sheet key
Page-11
4. Transporting
Transfer the controller to its installation place by use of a crane, a forklift, or a hand lifter.
When to transfer it by use of a crane, use eye bolts (at 2 portions). And when to use a
WARNING forklift or a hand lifter, transfer the controller so that it should not fall down.
Printed boards and other precision devices are used in the controller; therefore do not
give any impact during transfer. When hoisting the controller using a crane, take care that
WARNING none of the parts on the controller will be damaged by the wires.
Folklift
5. Installation
A robot controller has a through-hole for an external connection cable on its right side and back
side. To install a robot controller, secure a space of 400 mm at least for external connection cable.
Page-19
After the robot controller has been installed, shut the door completely, and check that the door has
been locked by the keys provided for this purpose. Dirt, dust and other foreign matter may find their way
inside the robot controller if its door is not completely shut, possibly causing it to fail. Also lock the circuit
breaker of the controller using the key provided for this purpose. Be absolutely sure to entrust the
safekeeping of the key for the circuit breaker padlock to a specially designated person or the person in
charge of safety management. (The padlock is to be provided by customer)
Door key can be locked. If necessary, lock them and a specially designated person or the person in
charge of safety management should charge the key.
Page-20
6. Type of controller
Controller type
Primary
Specification transformer
power voltage
FD11-0000 Domestic (JIS) AC200V without transformer
FD11-1101 For North America (ANSI、NFPA79) AC400V with transformer
FD11-0100 For both Domestic and Abroad AC400V with transformer
North America Headquarters Phone: 248-305-6545 Fax: 248-305-6542 42775 W. 9 Mile Rd. Novi, Michigan 48375, U.S.A
Indiana Service Center Phone: 502-517-1553 Fax: 317-535-3659 715 Pushville Road, Greenwood, Indiana, 46143, U.S.A.
South Caroline Service Center Phone: 864-458-8000 Fax: 864-458-8256 1310 Garlington Road, Suite L, Greenville, SC 29615, U.S.A.
Canada Branch Office Phone: 905-760-9542 Fax: 905-760-9477 89 Courtland Ave., Unit No.2, Concord, Ontario, L4K 3T4, CANADA
Phone: Fax: Unit 3, 92, Kettles Wood Drive, Woodgate Business Park,
U.K. branch
+44-0121-423-5000 +44-0121-421-7520 Birmingham B32 3DB, U.K.
Phone: Fax:
Sydney office Unit 1, 23-29 South Street, Rydalmere, N.S.W, 2116, AUSTRALIA
+61-(0)2-9898-1511 +61-(0)2-9898-1678
Phone: Fax:
Brisbane office 7/96 Gardens Dr,Willawong,QLD 4110, , AUSTRALIA
+61-(0)7-3272-4714 +61-(0)7-3272-5324