Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., MY4-DC6).
Part number
Single contact Bifurcated contact
Standard Upper Lower Standard Upper Lower
Contact bracket mounting mounting bracket mounting mounting
Type Terminal form Construction mounting bracket bracket mounting bracket bracket
Standard Plug-in/solder DPDT Unsealed MY2 MY2F MY2S MY2Z MY2ZF MY2ZS
3PDT MY3 MY3F MY3S — — —
4PDT MY4 MY4F MY4S MY4Z MY4ZF MY4ZS
PCB DPDT MY2-02 — — MY2Z-02 — —
3PDT MY3-02 — — — — —
4PDT MY4-02 — — MY2Z-02 — —
Plug-in/solder 4PDT Sealed MYQ4 — — MYQ4Z — —
PCB 4PDT MYQ4-02 — — MYQ4Z-02 — —
Plug-in/solder 4PDT Hermetically MY4H — — MY4ZH — —
PCB 4PDT Sealed MY4H-0 — — MY4ZH-0 — —
Note: 1. For SEV approved type, order the following: MY4-SV-DC6. (Lloyd's Register approval. See “Approvals” section.)
2. To order connecting sockets and mounting tracks, see “Accessories” section.
3. AgCdO contacts are also available (MY2E, MY3E, MY4E). Contact your OMRON sales representative for details.
MY MY
Part number
Single contact Bifurcated contact
Standard Upper Lower Standard Upper Lower
Contact bracket mounting mounting bracket mounting mounting
Type Terminal form Construction mounting bracket bracket mounting bracket bracket
LED indicator Plug-in/solder DPDT MY2N — — MY2ZN — —
3PDT MY3N — — — — —
4PDT MY4N — — MY4ZN — —
High-capacity DPDT w/o LED MY2-Y — — — — —
indicator
LED indicator MY2N-Y — — — — —
Diode surge DPDT MY2-D — — MY2Z-D — —
suppression* 3PDT MY3-D — — — — —
4PDT MY4-D — — MY4Z-D — —
LED indicator DPDT MY2N-D2 — — MY2ZN-D2 — —
and diode surge 3PDT MY3N-D2 — — — — —
suppression* 4PDT MY4N-D2 — — MY4ZN-D2 — —
RC circuit** DPDT w/o LED MY2-CR — — MY2Z-CR — —
3PDT indicator MY3-CR — — — — —
4PDT MY4-CR — — MY4Z-CR — —
DPDT LED indicator MY2N-CR — — — — —
4PDT MY4N-CR — — — — —
Push-to-test DPDT MY214 — — MY2Z12 — —
button 4PDT MY414 — — MY4Z12 — —
LED indicator DPDT MY214N — — MY2Z12N — —
and RC circuit 4PDT MY414N — — MY4Z12N — —
Note: 1. For SEV approved type, order as the following: MY4-SV-DC6. (Lloyd's Register approval. See “Approvals” section.)
2. To order connecting sockets and mounting tracks, see “Accessories” section.
3. AgCdO contacts are also available. Contact your OMRON sales representative for details.
4. * DC coils only
** AC coils only
■ ACCESSORIES
Connecting Sockets
To Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the available types chart.
Available Types
Track mounted sockets
2
MY MY
Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length.
Specifications
■ CONTACT DATA
Non-latching – Unsealed
3
MY MY
■ COIL DATA
Non-latching – AC
Coil inductance
Coil (ref. value) (H) Pick-up Dropout Maximum Power
Rated Rated current (mA) resistance Armature Armature voltage voltage voltage consumption
voltage (V) 50 Hz 60 Hz (Ω) OFF ON (% of rated voltage) (VA, W)
6 214.10 183 12.20 0.04 0.08 80% max. 30% min. 110% max. Approx.
12 106.50 91 46 0.17 0.33 1.00 to 1.20
24 53.80 46 180 0.69 1.30
50 25.70 22 788 3.22 5.66
100/110 11.70/12.90 10/11 3,750 14.54 24.60 Approx.
110/120 9.90/10.80 8.40/9.20 4,430 19.20 32.10 0.90 to 1.10
200/220 6.20/6.80 5.30/5.80 12,950 54.75 94.07
220/240 4.80/5.30 4.20/4.60 18,790 83.50 136.40
Non-latching – DC
Coil inductance
Coil (ref. value) (H) Pick-up Dropout Maximum Power
Rated resistance Armature Armature voltage voltage voltage consumption
voltage (V) Rated current (mA) (Ω) OFF ON (% of rated voltage) (VA, W)
6 150 40 0.17 0.33 80% max. 10% min. 110% max. Approx.
12 75 160 0.73 1.37 0.90
24 36.90 650 3.20 5.72
48 18.50 2,600 10.60 21.00
100/110 9.10/10 11,000 45.60 86.20
Latching – AC
Latching – DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
AC rated current, and ±15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Because the coil is designed for low power consumption, connect a bleeder (if necessary after confirming the leakage
current), when the coil is driven by an SCR.
5. For AC type latching coils, the rated current values are half-wave rectified current values measured with a DC ammeter.
4
MY MY
■ CHARACTERISTICS
Non-latching
Latching
5
MY MY
■ CHARACTERISTIC DATA
Maximum switching capacity – Non-latching
MY2, MY3 MY4 MY4(Z)H MYQ4(Z)H
Rated operating current (A) Rated operating current (A) Rated operating current (A) Rated operating current (A)
6
MY MY
Dimensions
Unit: mm (inch)
■ RELAYS
MY2 MY3 MY4
■ -02
MY■ Mounting holes
■F
MY■ Mounting holes
Note: The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-pole type.
7
MY MY
Unit: mm (inch)
■ RELAYS (continued)
MY(Z)H MY4(Z)H-0
■ -5
MY■ Mounting holes Terminal arrangement
(Bottom view)
MY2 MY3
Note: The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and
3-pole types are identical the 4-pole type. MY4, MYQ4(Z), MY4(Z)H, MY4H-0
MYQ4(Z) MYQ4(Z)-02
8
MY MY
Unit: mm (inch)
■ ACCESSORIES
Track mounted sockets (UL File No. E87929) (CSA Report No. LR46088)
PYF08A-E Terminal arrangement/ PYF11A Terminal arrangement/
mounting holes mounting holes
(Top view) (Top view)
Back connecting socket (UL File No. E87929) (CSA Report No. LR46088) – DPDT
PY08 PY08QN PY08-02
Back connecting socket (UL File No. E87929) (CSA Report No. LR46088) – 3PDT
PY11 PY11QN PY11-02
Note: 1. UL/CSA does not apply to wire wrap (Q) type sockets.
■ CR.
2. Value in brackets is for MY■
9
MY MY
Unit: mm (inch)
■ ACCESSORIES (continued)
Back connecting socket (UL File No. E87929) (CSA Report No. LR46088) – 4PDT
PY14 PY14QN PY14-02
■ -CR.
Note: Value in brackets is for MY■
Mounting holes
DPDT 3PDT 4PDT
10
MY MY
* This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N.
** L = Length
PFP-50N ............... L = 497.84 mm (19.60 in)
PFP-100N ............... L = 990.60 mm (39.00 in)
PFP-100N2 ............... L = 990.60 mm (39.00 in)
*** A total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the track at a pitch
of 9.91 (0.39) between holes.
11
MY MY
Unit: mm (inch)
■ ACCESSORIES (continued)
Socket mounting plates [t=1.52 (.06)]
■ RELAY OPTIONS
LED Indicator Terminal arrangement/Internal connections (Bottom view)
Specifications and dimensions same as the standard type MY4N
with the following exception. Because an LED indicator is DC coil rating type AC coil rating type
employed as the operation indicator, the rated current is
approximately 3.8 mA higher in the DC types and 0.5 to 5 mA
higher in the AC types than in the standard type.
Ambient operating temperature: -55° to 60°C (-67° to 140°F).
Green LED ............ DC
Red LED ............... AC
Note: 1. In MY2N and MY3N, only the contact circuit is different from the illustration below. The coil terminals 10 and 11 of MY3N
become (-) and (+), respectively.
2. Pay special attention to the polarities when using the DC type.
3. The AC coil-type is provided with a self-diagnostic function that detects a breakage in the coil.
RC Circuit
Specifications and dimensions same as the standard type with the Terminal arrangement/
following exceptions. Internal connections
The panel cutout dimensions are the same as those of the standard type. (Bottom view)
However, the height is higher by 17.02 mm (0.67 in).
Note: 1. The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-
pole type.
2. Available on AC versions only.
3. Terminal arrangement/internal connections: MY2-Y is the same as the standard type; MY2N-Y is the same as the LED
indicator type.
12
MY MY
Characteristic Data
Without RC circuit With RC circuit
Push-to-test button
■ 12
MY■ Mounting holes
When mounting the relay, use the connecting socket PYC-P2 shown
in “ACCESSORIES” section. The mounting hole dimensions shown
here are applicable to the relay with mounting stud.
Note: The dimension drawings show the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-pole type.
Note: 1. Pay special attention to the polarities when using the DC type.
2. The release time is somewhat longer, but satisfies the standard specifications of 25 ms.
3. The reverse-breakdown voltage of the diode is 1,000 VDC.
4. Available on DC versions only.
Connecting sockets
Use the standard MY4 (4PDT) sockets with the terminal arrangements listed below.
Terminal arrangement/Internal connections (Bottom view)
AC DC
Note: 1. R is a resistor for ampere-turn compensation, and is incorporated in the relays rated at 50 VAC or above.
2. Pay attention to the polarity of the set and reset coils, as incorrect connection of positive and negative terminals will result in
malfunctioning of the relay.
13
MY MY
■ APPROVALS
UL recognized type (File No. E41515)
SEV listed type (File No. D791/63 [2- & 4-pole], D791/91 [3-pole])
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the
performance characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
14
MY MY
Cat. No. GC RLY6 9/97 Specifications subject to change without notice. Printed in the U.S.A.
15