3KXP200011R1001-DS 266GST Ast en C 06 2012
3KXP200011R1001-DS 266GST Ast en C 06 2012
3KXP200011R1001-DS 266GST Ast en C 06 2012
Proven sensor technology together with state-of-the-art New TTG (through-the-glass) key technology
digital technology — Enables quick and easy local configuration without the
— Large turn down ratio of up to 100:1 need to open the cover - even in environments with
explosion protection
Comprehensive selection of sensors
— Optimized performance and stability IEC 61508 certification
— For SIL2 (1oo1) and SIL3 (1oo2) applications
10-year stability
— 0.15 % of URL Full compliance with Pressure Equipment Directive (PED)
category III
Change from one to two columns
Model 266GST Gauge
Model 266AST Absolute
(Δ) Measuring range lower limit (LRL) for 266AST is 0 abs for all measuring ranges
Electrical data and options Integrated LCD display with TTG operation (code L5)
As with the integrated LCD display above, but featuring an
HART digital communication and 4 ... 20 mA output innovative TTG (through-the-glass) keypad which can be used
Power supply to activate the device's configuration and management menus
The transmitter operates from 10.5 ... 42 V DC with no load without having to remove the transmitter housing cover.
and is protected against reversed polarity (additional loads The TTG keys are protected against accidental activation.
enable operation above 42 V DC).
During use in Ex ia zones and in other intrinsically safe Surge protection (optional)
applications, the power supply must not exceed 30 V DC. Up to 4 kV
Minimum operating voltage with "surge protection" option: — Voltage: 1.2 μs rise time / 50 μs delay time at half value
12.3 V DC — Current: 8 μs rise time / 20 μs delay time at half value
Additional blocks
1 enhanced resource block
1 manufacturer-specific pressure with calibration
transducer block
1 manufacturer-specific advanced diagnostics transducer
block
1 manufacturer-specific local display transducer block
Number of VCRs
35
Output interface
PROFIBUS PA communication according to
PROFIBUS DP 50170 Part 2 / DIN 19245 Part 1-3.
Data blocks
1 "physical block"
3 "analog input" blocks
1 "pressure transducer block" with calibration
1 "transducer block" for local display
Electromagnetic field The total performance accuracy includes the measuring error
Meets all requirements of EN 61326 and NAMUR NE-21. (non-linearity including hysteresis and non-reproducibility), as
well as the thermal change in the ambient temperature as
Common-mode interference regards the zero signal and span.
No influence from 100 V rms @ 50 Hz, or 50 V DC
2
E perf = (E ΔTZ + E ΔTS ) 2 + E lin
Mounting position
The recommended mounting position is vertical, with the Eperf = Total performance
process connection pointing downward. EΔTZ = Effect of the ambient temperature on the
Any deviations from this position will lead to a zero error, zero signal
which can be corrected by adjusting the zero position. With EΔTS = Effect of the ambient temperature on the
measuring range codes C and F, a deviation of 90° has an measuring span
additional effect on the ambient temperature of up to 0.02 Elin = Measuring error
mbar/10K.
Long-term stability
± 0.15 % of URL over a period of 10 years
(± 0.05 % URL/year)
Terminals
HART version: Three connections for signal / external display,
for wire cross sections of up to 2.5 mm2 (14 AWG), and
connection points for testing and communication purposes
Fieldbus versions: Two signal connections (bus connection) for
wire cross sections of up to 2.5 mm2 (14 AWG)
Grounding
Internal and external ground terminals are provided for
6 mm2 (10 AWG) wire cross sections.
Change from two to one column
2 M+
4
3 60 10
2 40 80
0
20 10
% 0
0
Kent-Taylo r
+
+
+
4
- 691HT
-
F1 F2 F3 F4
PV
TRI M
A B C D E F G H I
1 2 3
J K L M N O P Q R
4 5 6
S T U
@ %
7
V W X
8
& /
Y Z #
9
+
3
0 -
M10023
The HART handheld terminal can be connected to any wiring termination point in the loop, provided there is a minimum
resistance of 250 Ω between the handheld terminal and transmitter power supply. If this is less than 250 Ω, additional resistance
needs to be incorporated in order to enable communication.
Fieldbus versions
HART version
1 2
97 (3.82)
53 (2.09)
3
22 (0.87)
1 2
42 (1.65)
- +
79 (3.11) 52 (2.05)
69 (2.72)
M10028
XX XX XX XX
Accuracy
Base accuracy 0.025 % (Note: 4) D1
Explosion Protection Certification
ATEX Group II Category 1 GD - Intrinsic Safety Ex ia E1
ATEX Group II Category 1/2 GD - Flameproof Ex d (Note: 1) E2
ATEX Group II Category 3 GD - Type of protection "N" Ex nL design compliance E3
FM approval (Canada, CSA) Class I, II, Div. 1, 2, Group A to F (XP, IS, NI)
(Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) E4
FM approval (USA) Class I, II, Div. 1, 2, Group A to F (XP, IS, Nl)
(Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) E6
FM approvals (USA and Canada) Intrinsic Safety EA
FM approvals (USA and Canada) Explosion-proof (Note: 1) EB
FM approvals (USA and Canada) Non-incendive EC
Combined ATEX, FM and CSA (Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) EN
Combined ATEX - Intrinsic Safety, Flameproof and Type „N“ (Note: 1) EW
IEC Approval Group II Category 1 GD - Intrinsic Safety Ex ia E8
IEC Approval Group II Category 1/2 GD - Flameproof Ex d (Note: 1) E9
IEC Approval Group II Category 3 GD - Type of protection "N" Ex nL design compliance ER
NEPSI IIC Ex ia EY
NEPSI IIC Ex d (Note: 1) EZ
NEPSI IIC Ex nL ES
Combined NEPSI Ex ia and Ex d (Note: 1) EP
Combined NEPSI Ex ia, Ex d and Ex nL (Note: 1) EQ
Other Explosion Protection Certifications
GOST Russia - Ex ia W1
GOST Russia - Ex d (Note: 1) W2
GOST Kazakhstan - Ex ia W3
GOST Kazakhstan - Ex d (Note: 1) W4
Inmetro Brazil - Ex ia W5
Inmetro Brazil - Ex d (Note: 1) W6
Inmetro Brazil - Ex nL W7
Integral LCD
With integral LCD display L1
TTG (Through The Glass) integral digital LCD display L5
XX XX XX
Explosion Protection Certification
ATEX Group II Category 1 GD - Intrinsic Safety Ex ia E1
ATEX Group II Category 1/2 GD - Flameproof Ex d (Note: 1) E2
ATEX Group II Category 3 GD - Type of protection "N" Ex nL design compliance E3
FM approval (Canada, CSA) Class I, II, Div. 1, 2, Group A to F (XP, IS, NI)
(Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) E4
FM approval (USA) Class I, II, Div. 1, 2, Group A to F (XP, IS, Nl)
(Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) E6
FM approvals (USA and Canada) Intrinsic Safety
(Only available with 1/2-14 NPT or M20 electrical connections) EA
FM approvals (USA and Canada) Explosion-proof
(Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) EB
FM approvals (USA and Canada) Non-incendive
(Only available with 1/2-14 NPT or M20 electrical connections) EC
Combined ATEX, FM and CSA (Only available with 1/2-14 NPT or M20 electrical connections) (Note: 1) EN
Combined ATEX - Intrinsic Safety, Flameproof and Type „N“ (Note: 1) EW
IEC Approval Group II Category 1 GD - Intrinsic Safety Ex ia E8
IEC Approval Group II Category 1/2 GD - Flameproof Ex d (Note: 1) E9
IEC Approval Group II Category 3 GD - Type of protection "N" Ex nL design compliance ER
NEPSI IIC Ex ia EY
NEPSI IIC Ex d (Note: 1) EZ
NEPSI IIC Ex nL ES
Combined NEPSI Ex ia and Ex d (Note: 1) EP
Combined NEPSI Ex ia, Ex d and Ex nL (Note: 1) EQ
Other Explosion Protection Certifications
GOST Russia - Ex ia W1
GOST Russia - Ex d (Note: 1) W2
GOST Kazakhstan - Ex ia W3
GOST Kazakhstan - Ex d (Note: 1) W4
Inmetro Brazil - Ex ia W5
Inmetro Brazil - Ex d (Note: 1) W6
Inmetro Brazil - Ex nL W7
Integral LCD
With integral LCD display L1
TTG (Through The Glass) integral digital LCD display L5
www.abb.com