Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
135 views

Crack Width-Crm

This document calculates the crack width of a 15m deep tunnel slab as per IS 456-2000 standards. It provides details of the slab dimensions, reinforcement sizes and spacing, material properties, and steps to calculate the neutral axis depth, tensile and compressive stresses, surface strain, and design crack width. The calculated crack width of 0.0631mm is less than the permissible limit of 0.2mm, indicating it is within safe limits.

Uploaded by

rammohan
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views

Crack Width-Crm

This document calculates the crack width of a 15m deep tunnel slab as per IS 456-2000 standards. It provides details of the slab dimensions, reinforcement sizes and spacing, material properties, and steps to calculate the neutral axis depth, tensile and compressive stresses, surface strain, and design crack width. The calculated crack width of 0.0631mm is less than the permissible limit of 0.2mm, indicating it is within safe limits.

Uploaded by

rammohan
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

806080000

3325
242430.08
492.37189
NAGARJUNA CONSTRUCTION COMPANY LIMITED
Engineering Design and Technology Department
CONSTRUCTION GROUP
2
PROJECT: DOCUMENT NO.
Tunnel 15m deep
DESIGNED CHECKED
RMHS
STRUCTURE:

CALCULATION OF CRACK WIDTH AS PER IS 456-2000 (ANNEX F)

Permissible Crack Width (As per IS456- 35.3.2) = 0.2

Maximum Service Moment, Ms = 21.63

Width of cross section, b = 1000

Overall Thickness Of Slab, h = 200

Clear Cover in Tension Face = 30

Clear Cover in Compression Face, dc = 30

Grade of Concrete, fck = M25

Grade of Steel, fy = Fe415

Diameter of Tension Reinforcement (Equivalent diameter of bundle bars) 10

Spacing of Tension Reinforcement = 75

Diameter of Compression Reinforcement = 10

Spacing of Compression Reinforcement = 0

Effective Depth, d = 200 - 30 - 10 / 2 = = 165

Area of Tension Reinforcement , Ast = 1047

Percentage of Tension Reinforcement = 0.635

Area of Compression Reinforcement, Asc = #DIV/0!

Percentage of Compression Reinforcement = 0.38

Modulus of Elasticity of Steel, Es = 2.0E+05

Modulus of Elasticity of Concrete, Ec (=5000 x fck ) = 25000

Modular Ratio, m = 280/3scbc = = 10.98

Neutral Axis depth, x = 40.3

(By solving Eq: b x2/2 +(1.5 m -1)Asc(x-dc))= m Ast (d-x)

Lever Arm, z = d - x/3 = 165 -40.3/3 = 151.6

Tensile Stress in Steel, fs = Msx106 /(Ast*(d-x/3)) = 136.3

< 0.555fy

Comptressive Stress in Concrete, fcb = x fs/m(d-x) 4.0

Page 2
NAGARJUNA CONSTRUCTION COMPANY LIMITED
Engineering Design and Technology Department
CONSTRUCTION GROUP
3
PROJECT: DOCUMENT NO.
Tunnel 15m deep
DESIGNED CHECKED
RMHS
STRUCTURE:

< 0.333fck

e=
1
( h - x ) x fs = 8.726E-04
( d - x) x Es

Page 3
NAGARJUNA CONSTRUCTION COMPANY LIMITED
Engineering Design and Technology Department
CONSTRUCTION GROUP
4
PROJECT: DOCUMENT NO.
Tunnel 15m deep
DESIGNED CHECKED
RMHS
STRUCTURE:

e=2 b(h-x)(h-x) = 3.255E-04


3EsAst(d-x)

Average Surface Strain, e = e1 - e2


m = 5.470E-04

Distance from the Point Considered to the Surface of the

Nearest Longitudinal Bar,acr = 46.3

Design Crack Width, w =

= 3 x 46.3 x 0.000547 / 1000 = 0.0631


1 + 2 * ( ( 46.3 - 30 ) / ( 200 - 40.3 ) )
< 0.2mm Safe

Page 4
NAGARJUNA CONSTRUCTION COMPANY LIMITED
Engineering Design and Technology Department
CONSTRUCTION GROUP
5
PROJECT: DOCUMENT NO.
Tunnel 15m deep
DESIGNED CHECKED
RMHS
STRUCTURE:

Page 5
6
DATE

PAGE

mm

kNm

mm
Result On/Off
mm

mm

mm

mm

mm

mm

mm

mm

mm2

mm2

N/mm2

N/mm2

mm

mm

N/mm2

O.K.

N/mm2

Page 6
7
DATE

PAGE

O.K.

Page 7
8
DATE

PAGE

mm

mm

0.2mm Safe

Page 8
9
DATE

PAGE

Page 9

You might also like