1-Fisher Specification and Sizing Sheets - RevC
1-Fisher Specification and Sizing Sheets - RevC
1-Fisher Specification and Sizing Sheets - RevC
Sizing Type: Liquid Flow is Turbulent Solving for: Cv Noise is Hydrodynamic Flow is Mass
Variable Name Units Minimum1 Normal 1 Maximum 1 Minimum2
SERVICE & SIZING
Liquid CONDENSATE CONDENSATE CONDENSATE CONDENSATE
Inlet fluid density (Rho1) kg/m3 851.50 978.50 976.60 851.50
Inlet Pressure (P1) bar(g) 0.04000 0.04000 0.04000 0.08000
Pressure Change (dP) bar 0.00200 0.00100 0.01000 0.00200
Inlet Temperature (T1) deg C 65.0000 45.0000 6.9000 65.0000
Mass Flow Rate Liquid (wl) kg/h 30.0000 30.0000 900.0000 30.0000
Pressure Recovery Factor (Fl) 0.960 0.960 0.960 0.960
Valve style modifier (Fd) 0.092 0.104 0.377 0.092
Cavitation coefficient (Kc) 0.600 0.600 0.600 0.600
Dynamic Viscosity (Mu) cP 2.144 0.635 0.422 2.144
Vapor Pressure (Pv) bar(g) 0.01000 0.01000 0.01000 0.01000
Critical Pressure (Pc) bar(g) 85.00000 85.00000 85.00000 85.00000
Atmospheric Pressure psi 14.69 14.69 14.69 14.69
Pipe Size Up in 2 2 2 2
Pipe Schedule Up 40S 40S 40S 40S
Pipe Size Down in 2 2 2 2
Pipe Schedule Down 40S 40S 40S 40S
Nominal Valve Diameter (dv) in 1.000 1.000 1.000 1.000
NOISE CALCULATION
Hydrodynamic Trim Standard Trim Standard Trim Standard Trim Standard Trim
Valve Lpa (LpAe1m) dB(A) < 50 < 50 < 50 < 50
VELOCITY OUTPUTS
V1 Pipe ft/s 0.015 0.013 0.388 0.015
V2 Pipe ft/s 0.015 0.013 0.388 0.015
Valve/Regulator Sizing Calculation
Customer: ENGINEERING PROCUREMENT AND PROJECT Emerson FZE
1053
Contact: Mourad Elloumi Contact: Ajeesh.Karothukuzhy
Customer Reference: AR 0618 Control Valves Sales Office Reference: Lead Time:
Item: 100 Rev: Qty: 1 Quote: 320-AKD-190627-0046745/HIGH PRESSURE Rev: C
SEPARATOR TIE-IN AT THE WEST QURNA
Tags: 22-273-00-LV-001 Date Last Modified: 10/06/2019
Description: NPS 1 EZ Special Tagging 667 Size 40i DVC6200 Factory Mtgs DVC6200/DVC2000 Process Level 3 Global Drawings
Charges/Services -EU Charges/Services -EU
Service Description: Condensate to OWS line
Sizing Type: Liquid Flow is Turbulent Solving for: Cv Noise is Hydrodynamic Flow is Mass
Variable Name Units Normal 2 Maximum 2
SERVICE & SIZING
Liquid CONDENSATE CONDENSATE
Inlet fluid density (Rho1) kg/m3 978.50 976.60
Inlet Pressure (P1) bar(g) 0.08000 0.08000
Pressure Change (dP) bar 0.01000 0.01000
Inlet Temperature (T1) deg C 45.0000 6.9000
Mass Flow Rate Liquid (wl) kg/h 380.0000 900.0000
Pressure Recovery Factor (Fl) 0.960 0.960
Valve style modifier (Fd) 0.211 0.377
Cavitation coefficient (Kc) 0.600 0.600
Dynamic Viscosity (Mu) cP 0.635 0.422
Vapor Pressure (Pv) bar(g) 0.01000 0.01000
Critical Pressure (Pc) bar(g) 85.00000 85.00000
Atmospheric Pressure psi 14.69 14.69
Pipe Size Up in 2 2
Pipe Schedule Up 40S 40S
Pipe Size Down in 2 2
Pipe Schedule Down 40S 40S
Nominal Valve Diameter (dv) in 1.000 1.000
NOISE CALCULATION
Hydrodynamic Trim Standard Trim Standard Trim
Valve Lpa (LpAe1m) dB(A) < 50 < 50
VELOCITY OUTPUTS
V1 Pipe ft/s 0.164 0.388
V2 Pipe ft/s 0.164 0.388
Item Notes: