RA 9514 - FIRE INSPECTION SURVEY AND MAPPING Examination Key

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

COURSE : FIRE ARSON INVESTIGATION AND INSPECTION (FAIIC)

MODULE : FIRE INSPECTION SURVEY AND MAPPING


LECTURER : SUPT ARNEL A INANDAN, DPA
SUBJECT : Examination Key

1. The document that gives authority to the Fire Safety Inspectors to conduct survey on the fire
safety compliance of a particular establishment;
a. Standard checklist b. Memorandum
c Reference Order d. Inspection order

2. Hazardous areas being considered for inspection includes;


a. Kitchen b. Windows
c Basement d. All of the above

3. Nature of inspection conducted annually;


a. Application for business permit b. Periodic inspection of occupancy
c Inspection for Philhealth accreditation d. Building under inspection

4. It surveys the name of the building, owners, address and other company circumstances of the
premises being inspected;
a. Latest FSIC issued b. Business permit
c General information d. None of the above

5. It indicates the usage of each floor, section or rooms;


a. Building plans b. Business permit
c Building construction d. Sectional occupancy

6. The nature of inspection conducted before new business permit is issued;


a. Building under construction b. Application for occupancy permit
c Periodic inspection of Occupancy d. Application for business permit

7. The number of persons that can safely be accommodated in level means of egress components;
a. Capacity of horizontal exit b. Capacity of exit stair
c Load factor d. None of the above

8. The number of persons that can safely be accommodated in stair means of egress components;
a. Occupant load b. Means of egress
cCapacity of exit stair d. Occupants

9. The minimum number of permissible exit component, unless exempt by other provisions of the
Fire Code of the Philippines;
a. 4 b. 3
c 1 d. 2

10. The most important classification that the fire safety inspectors have to identify to be able to use
the correct checklist;
a. Occupancy classification b. Occupancy permit
c Occupant load d. Sectional occupancy
11. The maximum number of persons allowed to occupy an area, room or space;
a. Sectional occupancy b. Load factor
cOccupant load d. All of the above

12. The fire rating for enclosure when the building is 3storeyand below;
a. 4-hour b. 2-hour
c 3-hour d. 1-hour

13. List of violations and non-compliance to the provisions of the Fire Code;
a. Defects and deficiencies b. Standard checklist
c Ruinous building d. Imminent danger

14. The minimum number of exits when the occupant load is more than 1000 persons;
a. 5 b. 4
c 3 d. 2

15. The fire rating for enclosure when the building is 4 storey or more;
a. 5-hour b. 4 hour
c 3-hour d. 2-hour

16. Inspection of building service equipment includes the following;


a. Boiler b. Generator set
cGarbage handling facility d. All of the above

17. All of the following are features of fire protection, except;


a. Alarm system b. Standpipe system
c Portable fire extinguishers d. Emergency lights

18. The heading under which the list of corrective measures to address the violations or non-
compliance of the Fire Code are written;
a. Standard checklist b. Occupancy classification
c Inspection order d. None of the above (Recommendation)

19. An area safe from the by-products of combustion;


a. Exit b. Area of safe refuge
c Exit access c. Hallway

20. The authorized representative of the Fire Chief to conduct fire safety survey and mapping:
a. City Fire Marshal b. Municipal Fire Marshal
c Fire Safety Inspector d. All of the above