Datasheet Cofraplus 60
Datasheet Cofraplus 60
Datasheet Cofraplus 60
Cofraplus® 60
Cofraplus® 60 is a trapezoidal profile sheet with lateral embossments
at its web intended to realise composite slabs.
The embossments ensure the longitudinal shear bond between
the concrete and the steel profile which acts than as additional
reinforcement to the slab construction. The profile serves as
formwork in the pouring phase of the concrete and allows savings
to be made on the low reinforcement layer and to its self-weight
due to the trapezoidal geometry. A multi-use profile, Cofraplus® 60
is suitable for all types of construction. Upon request, the standard
5 ribs profile with a cover width of 1035mm can be delivered only
with 4 ribs and a smaller cover width of 828mm to reduce scrap by
offcuts and site operations.
d
58
207 101 Fire safety Light Economical Video
62
Cover width : 1 035 mm Coated face
CE - Marking
French technical approval : DTA No. 3/15-800
Characteristics of the base material Norms Nominal thickness of the profile
Steel grade S 350 GD EN 10346 Characteristics sheet [mm]
P 34-310 0,75 0,88 1,00 1,25
Galvanised steel ZM 175 ETPM ZMevolution or
Type of corrosion AbZ Z-30.11-61 Weight [kg/m ] 2
8,53 10,00 11,37 14,22
protection
Galvanised coated steel P 34-301 Cross section Ap: [mm /m] 2
1 029 1 217 1 391 1 797
ZM 175 EN 10169+A1
Organic coating Norms Effective inertia Ieff [mm /m] 443 700 526 400 600 800 751 000
4
Category IIIa P 34-310 Height of neutral axis [mm] 33,70 33,70 33,70 33,70
Hairplus 25 µm
Category CPi3 EN 10169+A1
Other coatings On demand Modulus of inertia [mm3/m] 13 160 15 620 17 830 22 280
Cofraplus® 60 C: Cofraplus® 60 P:
If shear connectors are welded or nailed to the across the Pre-punched version, compatible with shear connectors welded
profile sheet to the beam, the Cofraplus® 60 C version brings in advance or in shop to composite beams.
advantages. The spacing between the 2 stiffners in the lower
flange permits to well position the connector.
According EN1994-1-2 4.3.2, Cofraplus® 60 composite floors are rated REI 30 even without specific reinforcement in the rib.
For higher fire resistance classes, reinforcement bars are required. These are positioned in the ribs of the profile. Their size is determined by
calculation (see Cofra5).
Sound insulation
The acoustic behaviour of a raw composite slab is determined by its mass.
Values calculated by modelling – study report CSTB No. AC15-26054708
Thickness of the slab [cm]
11 12 13 14 15 16 17 18 20
Rw [dB] 46 47 48 48 49 50 51 52 53
(C;Ctr) [dB] (-2;-6) (-2;-6) (-2;-6) (-1;-6) (-1;-6) (-2;-6) (-2;-7) (-2;-7) (-2;-7)
Structural performance
Acceptable unweighted q values with g’ = 0 in kg/m2
A calculation using Cofra 5 might optimise the given values according to the project requirements
Single span L
Assumptions Thickness
Key [mm]
Concrete C25/30 (Density 2500 kg/m ) 3
0,75
Fire resistance REI30 Installation without
0,88
Deflection while pouring L / 180 propping
1,00
Deflection in service L [cm] / 350 if L < 3.5 m or (0.5 cm + L / 700) if L > 3.5 m
With propping 0,75