Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ABS Aeration Product Overview PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 78

ABS Aeration Product Overview Sulzer Pumps

The Heart of Your Process


ABS Aeration Products Sulzer Pumps

ABS NOPON Membrane/Porous ABS NOPON Submersible


Disc Diffuser System Aerator Mixer OKI

Self-aspiration Aerator TA/TAK


Venturi - Jet

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 2


ABS NOPON Disc Diffuser System (DDS) Sulzer Pumps

Membrane disc diffuser: Coarse disc diffuser:


PIK300、PRK 300、KKI 215、 HKL 215、MKL215
DS20*

Membrane :PIK 300 Coarse :HKL 215

Diffuser diameter 330 mm ( 13”) Diffuser diameter 215 mm ( 7”)


Air flow rate 1,0 - 10 m3/h (20°C; 101,3 kPa) Air flow rate 1 - 5 m3/h (20°C; 101,3 kPa)
Net membrane surface area = 0,06 m2 Net disc surface area = 0,025 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 3


Sulzer Pumps

Zone header
(Manifold)

Drop leg
pipe

Disc diffuser

Mounting Pipe
brackets (diffuser header)

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 4


Sulzer Pumps

Water drainage) Closed


loop pipe

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 5


Available Materials Sulzer Pumps

Diffuser body PP uPVC

Membrane disc EPDM -

Porous disc HDPE

SS Disc AISI 316

Pipes uPVC PP

Zone headers uPVC PP AISI 316

Mounting brackets uPVC AISI 316

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 6


ABS DDS Delivery Range Sulzer Pumps

1. Blowers station 8. Diffusers header


2. Air main pipe 9. Diffuser
3. Dropleg pipe 10. Drainage (purge) connection
4. Bottom zone header 11. Condense collecting pipe
5. SS Zone header support 12. Flexible or rigid purge pipe
6. PVC header support 13. Support bracket
7. Joint sleeve 14. Expansion joint

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 7


PIK 300 Sulzer Pumps

Diffuser diameter 330 mm ( 13”)


Air flow rate 1,0 - 10 m3/h (20°C; 101,3 kPa)
Net membrane surface area = 0,06 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 8


1 - 3 mm Fine Bubbles Sulzer Pumps

Higher the total inter-face area gas bubbles to water,


higher is the gas volume transfer.

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 9


PIK 300 components Sulzer Pumps

5120 membrane slits

Max/min distance between diffusers


and between air pipes:

Min Max
X, mm 400 1250/1450
Y, mm 400 1250/1450

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 10


Sulzer Pumps

SOTE Performances - PIK 300


4,00 m diffuser
SOTE % submergence
40.00
DD
25%
20%
35.00
15%
10%
5%

30.00

25.00

20.00

15.00
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00

Airflow/diffuser, m3/h (20°C ; 101,3 kPa)


DD = diffuser density = total effective membrane area/total tank bottom area

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 11


PRK 300 Sulzer Pumps

Diffuser diameter 330 mm ( 13”)


Air flow rate 1,0 - 10 m3/h (20°C; 101.3 kPa)
Net membrane surface area = 0.06 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 12


PRK 300 components Sulzer Pumps

Retrofitting opportunity

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 13


KKI 215 Sulzer Pumps

Diffuser diameter 215 mm ( 7”)


Air flow rate 0,5 - 4 m3/h (20°C; 101,3 kPa)
Net membrane surface area = 0,025 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 14


KKI 215 components Sulzer Pumps

1850 membrane slits

X
Max/min distance between diffusers
and between air pipes:

Min Max
X, mm 350 1000
Y, mm 350 1000

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 15


Sulzer Pumps

SOTE Performances - KKI 215


4,00 m diffuser
submergence
SOTE %35.00

30.00

DD
25.00
15 %
10 %
7%
20.00 5%

3%
15.00
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50

Airflow / diffuser, m3/h (20°C ; 101.3 kPa)


DD = diffuser density = total effective membrane area/total tank bottom area

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 16


DS 20 SUCOFLOW Sulzer Pumps

Diffuser diameter 520 mm ( 20”)


Air flow rate 1,0 - 20 m3/h (20°C; 101,3 kPa)
Net membrane surface area = 0,183 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 17


Sulzer Pumps

EPDM Membrane

Integrated independent check-valve

The diffuser can be installed on circular (uPVC,


SS ) pipes or square (SS) pipes

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 18


Sulzer Pumps

Example of bottom fixed SS installation

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 19


Example of to-the-bottom fixed installation Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 20


Sulzer Pumps

WWTP Frauenfeld CH

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 21


Available Porous disc diffusers Sulzer Pumps

Models:
HKL 215
MKL 215

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 22


HKL 215 Sulzer Pumps

Diffuser diameter 215 mm ( 7”)


Air flow rate 1 - 5 m3/h (20°C; 101,3 kPa)
Net disc surface area = 0,025 m2
Available with Ceramic Disc as HKC 215

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 23


HKL 215 components Sulzer Pumps

Double layer disc

X
Max/min distance between diffusers
and between air pipes:

Min Max
X, mm 350 1000
Y, mm 350 1000

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 24


SOTE Performances - HKL 215 Sulzer Pumps

4,00 m diffuser
SOTE % submergence
35.00

30.00

DD
25.00 15 %
9%
6%

20.00
4%

2%
15.00
0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50

Airflow / diffuser, m3/h (20°C ; 101,3 kPa)


DD = diffuser density = total effective membrane area/total tank bottom area

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 25


MKL 215 (Medium Bubble Diffuser) Sulzer Pumps

Diffuser diameter 215 mm ( 7”)


Air flow rate 1.5 - 6 m3/h (20°C; 101.3 kPa)
Net disc surface area = 0.025 m2

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 26


MKL 215 components Sulzer Pumps

Single layer disc

X
Max/min distance between diffusers
and between air pipes:

Min Max
X, mm 350 1000
Y, mm 350 1000

Medium bubble = 3 - 5 mm

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 27


SOTE Performances - MKL 215 Sulzer Pumps

SOTE %
30.00

25.00

DD
15 %
20.00 9%
6%
4%

15.00
2%

10.00
1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50

Airflow / diffuser, m3/h (20°C ; 101,3kPa)

DD = diffuser density = total effective membrane area/total tank bottom area

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 28


Nopol Clean System Sulzer Pumps

• Suitable for both porous and


membrane discs.
• Whenever the back pressure
increase reaches 20mbar.
• Both for membranes and
porous discs.
• To maintain constant back
pressure.
• To avoid all kinds of clogging PUMP MOTOR

and sliming. CONTROL PANEL

• To be used once a week to


PUMP FOR LIQUID
once a year depending waste FORMIC ACID

water.
ACID CONTAINER

PVC-HOSE BOX FOR


ACCESSORIES

POWER CABLE
Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 29
Sulzer Pumps

OKI
Submersible Aerator Mixer

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 30


Main characteristics Sulzer Pumps

Submerged unit
Suitable for continuos and or intermittent aeration
Suitable for both municipal and industrial WW aeration
Combined mixing and aeration
Non - clogging
Suitable in deep tanks
High oxygen transfer and mixing capacity
Liftable system; no process interruption for Service
Suitable for BNR processes (Biological Nutrient Removal)
Suitable for SBR processes (Sequencing Batch Reactor)
Suitable for MBR processes (Membrane Biological Reactor)
Suitable for MBBR process (Moving Bed Biological Reactor)
Suitable for feeding with O2gas

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 31


Main components Sulzer Pumps

Motor

Gearbox

Stator

Rotor

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 32


Sulzer Pumps

Stator
Rotor

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 33


Components Details Sulzer Pumps

1 Frame 7 Hose clamps 13 Lifting bail


2 Rotor 8 Rubber straps 14 Lifting cable
3 Stator and stator ducts 9 Process air hose 15 Power cable(s)
4 Nameplates 10 Hose flange for air main 16 Signal cable
5 Hose flange sealing 11 Heavy duty shaft seal 17 Cable support
6 Hose flange for O.K.I. 12 Drive unit (geared motor)
Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 34
OKI Product Series Sulzer Pumps

100 & 200

With non-submersible motor equipped with sealing and cooling jacket


(hood)

1000

Classic OKI Aerator Mixer

2000

New generation of OKI Aerator Mixer

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 35


OKI 100 & 200 series Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 36


OKI 1000 series Technical Specifications Sulzer Pumps

A AM AM2
continuous continuous continuous rpm/H rpm/L max
aeration aeration+ aeration+ SOTR
mixing at mixing at at 8 m
high speed low speed kg O2/h
without air without air

A 3.0 5.5 3,0/2,0 142 95 19**)

B 4.0 7.5 4,0/2,6 157 105 29

A 5.5 7.5 5/3,3 95 64 41

B 7.5 11 7,5/5 103 69 49

C 11.0 15 11/7,5 115 77 57

A 15.0 18.5 15/10 103 69 105

B 18.5 25 18,5/13 112 75 130

C 22.0 30 20/13 118 79 140

A 30.0 37*) 26/18,5 98 64 170

B 37.0 - 30/20 104 70 200


*) this model can be used as mixer at higher speed only after **) at 7 m
check and approval by the technical department
Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 37
Models Sulzer Pumps

• A-models are for continuous aeration

• AM-models are for aeration and mixing without air at high speed
(high mixing energy)

• AM2-models are for aeration and mixing without air at low speed (low
mixing energy)

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 38


Performances of OKI 1090 C SOTR / Airflow / Water depth Sulzer Pumps

SOTR kg O2/h

Water depths

Airflow/ m3/min

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 39


OKI 1000 Installed Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 40


OKI 1000 Series Rotor Sulzer Pumps

Rotor blade
Air pods

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 41


Working principle Sulzer Pumps

Compressed
air inlet

Water + Fine
Bubbles
outlets

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 42


Lab test arrangement Sulzer Pumps

Water + Fine
Bubbles at stator
duct outlet

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 43


OKI 2000 series Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 44


OKI 2000 series Rotor Sulzer Pumps

Air ports Rotor blade

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 45


Working principle Sulzer Pumps

Compressed
air inlet

Water + Fine
Bubbles
outlets

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 46


All are AM - models, i.e. for aeration and high energy mixing
Sulzer Pumps

Motor Motor Shaft


OKI Model Power Power (approx)
kW kW

2000A 15AM 15,00 14,40


2000B 22AM 22,00 20,10
2000C 30AM 30,00 25,80
2000D 37AM 37,00 34,00

Suitable for O2gas feeding

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 47


OKI 2000 installed Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 48


OKI Installation principle Sulzer Pumps

Lifting cable

Flexible process hose


and electrical cable

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 49


Cavendish Farms Inc., Canada. Food Industry. Aeration
tanks with 10 OKI submersible aerator mixers Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 50


Prague WWTP - Aerobic Sludge Digestion -
no.3 Digesters; WD = 14,00 m Sulzer Pumps

18 OKI submersible aerator mixers

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 51


Phoenix Pulp & Paper, Thailand.
Aeration tank with 10 OKI submersible aerator mixers Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 52


Mörrums Bruk Pulp Mill Sweden - MultiBioProcess Sulzer Pumps

10 OKI submersible 2000-30 + 5 HST S6000

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 53


Sulzer Pumps

TA/TAK
Submersible Self-aspirating Aerator

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 54


Main Characteristics Sulzer Pumps

Submerged unit (no needs of additional blower).


Suitable for continuous and or intermittent
aeration (aeration only).
Suitable for both municipal and industrial WW
aeration.
Very low clogging risks.
Suitable for water depth up to 7m.
Retrievable system; no process interruption for
Service.
Suitable for SBR processes (in combination
with submersible mixer).
SOTR range:3.0 - 80.0 kgO2/h.

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 55


Main Components Sulzer Pumps

Non-torquing water
tight encapsulated
cable entry with strain
relief

Dual mechanical seal system Water tight encapsulated


with outside sintered silicon squirrel cage NEMA B three
carbide seal, carbon/steel phase motor, class F insulation,
inside seal 155°C, thermal sensors in
each winding phase
DI-electrode seal leakage
monitor
Air inlet pipe
Oil chamber

Efficient diffuser
system jets air-waste
water mixture into Specially engineered star shaped Replaceable
tank impeller for creatings fine bushing
bubbles
Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 56
TA / TAK Submersible Aerator Sulzer Pumps

Operative water depth range


= 2,0 - 7,0 m

SOTR range = 3,0 - 80,0 kgO2/h

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 57


Working principles of TA / TAK Sulzer Pumps

Water +
Bubbles Water +
Water Bubbles
Air

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 58


TA units on duty Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 59


Starting sequence Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 60


Standard Material of Aerator TAxx1
Sulzer Pumps

Hex. Screw
TA 901 to 2400 Spring Washer

All hydraulic parts except bushing


Stainless steel AISI 304 Key

On request:
Stainless steel AISI 316Ti Motor Support
Hard Chrome layer
Impeller

Bushing Impeller Washer


Impeller Screw

Standard material: bronze Channel Ring


hardfibre on request
Bushing

Hydraulic Stator

Hex. Nut

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 61


Standard Material of Aerator TAxx2 Sulzer Pumps

Hex. Screw
TA 152 to 602 Spring Washer

Motor support --> AISI 316 cast s.s.


Impeller --> AISI 316 cast s.s. Key
hydraulic stator --> AISI 316 cast s.s.
Channel ring --> PUR on request also in SS 316
Motor Support

Impeller

Impeller Washer
Impeller Screw

Channel Ring

Bushing

Hydraulic Stator

Hex. Nut

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 62


Cast aerators: hydraulic end components Sulzer Pumps

Hydraulic Stator

Motor Support

Impeller
Channel Ring

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 63


Hydraulic Parts Aerator TA Sulzer Pumps

Hex. Screw
Material: casted Spring Washer
or welded stainless steel

Key

Motor Support

Impeller

Impeller Washer
Impeller Screw

Working side pushes liquid


Back side creates vacuum and aspirates air
Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 64
Hydraulic Parts Aerator TA Sulzer Pumps

Hex. Screw
Material: PUR or casted / welded
Spring Washer
stainless steel

Key

Motor Support

Impeller

Impeller Washer
Impeller Screw

Channel Ring

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 65


Distance of Gap between Impeller
Tip and Channel Ring Tip 0.75 mm

Impeller
Channel Ring

Wastewater Technology
Cast submersible aerators TA Sulzer Pumps

New generation with


cast stainless steel
hydraulics:

Hydraulic Stator
Impeller
Motor Support
Channel Ring

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 67


Submersible Aerator TAK
with Channel Extension 1.5 m long Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 68


Product Range Aerator TA/TAK 50 Hz Sulzer Pumps

TA 302
M60/4 + M90/4
(M2-Range) MU-IEM
TA 152
Weight= 122kg
M30/4 (M1-Range)
Impeller:
M40/4 (M2-Range) MU-IEM
dia 200mm; height
Weight= 76 kg
28mm
Impeller:
dia 220mm; height 18mm
max. w.d. 6,0 m
SOTR=7,5 kgO2/h
max. w.d. 5,0 m
SOTR=4 kgO2/h

TA 901
TA 602 M185/4 + M220/4
M110/4 -M160/4 (M4-Range) MU-DEM
(M3-Range) MU-IEM Weight= 360 kg
Weight= 211 kg Impeller:
Impeller: dia 282mm; height
dia 240mm; height 28mm
28mm
max. w.d. 8,0 m
max.w.d. 7,0 m SOTR= 21 kgO2/h
SOTR= 14 kgO2/h

TAK (beginning at 901model) improves the


oxygen transfer performance up to 25 %

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 69


Product Range Aerator TA/TAK 50 Hz Sulzer Pumps

TA 1200 TA 1800
M220/4 + M300/4 M370/4 - M450/4 (M4-Range)
(M4-Range) MU-DEM M550/4 (M5-Range)
Weight= 465 kg Weight= 785 kg
Impeller: Impeller:
dia 290mm; height 30mm dia 310mm; height 36mm

max. w.d. 6.5 m max. w.d. 9 m


SOTR= 30 kgO2/h SOTR= 46 kgO2/h

TA 2400
M550/4 + M750/4 (M5-Range)
Weight= 915 kg
Impeller:
dia 340mm; height 35mm

max. w.d. 7.5 m


SOTR= 70 kgO2/h

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 70


Sulzer Pumps

Venturi Jet

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 71


Venturi-Jet Principle Sulzer Pumps

Air
Suction
Inlet

Diffuser Mixing Zone

Mixed Flow
Venturi
Chamber
Water Inflow

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 72


Venturi-Jet Application Sulzer Pumps

 Aeration

 Tank Cleaning

 Tank Mixing

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 73


Venturi Aeration Advantages Sulzer Pumps

 Silent submerged operation


 No spray or aerosol formation
 Avoids odours
 No special installation structures needed
 Easy to exchange or expand
 Low investment cost

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 74


Venturi Tank Cleaning Applications m Sulzer Pumps

 Storm Water Tank cleaning


 Treatment plant overflow tanks
 Tank Cleaning in Industry

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 75


Venturi Tank Cleaning Advantages m Sulzer Pumps

 Air bubbles keep solids in suspension


 Pre-Aeration reduces load on the treatment plant
 Blockage free operation due to ContraBlock™
 Variety of installation options available
 Easy to exchange or expand
 Low investment cost

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 76


Installation Options Sulzer Pumps

Storm water tank


cleaning model

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 77


Tank Shapes Sulzer Pumps

Customer presentation | August 2011 Copyright © Sulzer Pumps | Slide 78