Rectangular Column Calculations

This document provides design calculations for a rectangular reinforced concrete column with equally spaced reinforcement on the perimeter. It includes load cases, material properties, column dimensions, reinforcement details, and calculations to check the column's capacity against the applied loads and moments. The detailed calculations show the column is safe for all load cases considered based on an interaction diagram comparing applied moment and axial load to the column's moment and axial capacity.

Uploaded by

Mikhail Tabucal
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

Rectangular Column Calculations

This document provides design calculations for a rectangular reinforced concrete column with equally spaced reinforcement on the perimeter. It includes load cases, material properties, column dimensions, reinforcement details, and calculations to check the column's capacity against the applied loads and moments. The detailed calculations show the column is safe for all load cases considered based on an interaction diagram comparing applied moment and axial load to the column's moment and axial capacity.

Uploaded by

Mikhail Tabucal
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Rectangular Column Calculations Issue: Design Page

Equally Spaced Reinf. on Perimeter 1 of 1

Project Owner: Mr and Ms Felicisimo M. Sumaya

Service Loads Ultimate Loads


Dead Live Wind E Load Case 1 2 3 4
Pu (kN) 12 16 5 0 Pu (kN) 17.3 40 39.4 33
Mu (kN.m) 10 15 10 10 Mu (kN.m) 22 39.5 42.375 43.65
Case 1: 0.9D+1.3W Case 3: 0.75(1.4D+1.7L+1.7W)
Reinforcement Concrete Case 2: 1.2D+1.6L Case4: 0.75(1.4D+1.7L+1.87E)
fy (MPa) 275 fc' (MPa) 24 Spiral Column
Es (MPa) 200000 ecu 0.003 Tied Co Tied Column
Side 2
Do not Consider displaced Conc.
Reinforcement Details Consider displaced Conc.

b (mm)

Edge 1
Edge 2
Location No. #
Edge 1 2 16 Column Dimensions Mu
Edge 2 2 16 b (mm) 200
Side 1 & Side 2 2 16 h (mm) 350

Cover (mm) 40 Side 1


r = As/(b*h) 0.02298
h (mm)
Detailed Calculations

c Mn Pn f f Mn f Pn
- 0.0 1589.786 0.75 0 1192 SAFE SECTION
453 3.8 1589.786 0.75 2.8727 1192
438 4.5 1589.786 0.75 3.3974 1192
423 5.3 1589.786 0.75 3.9593 1192
Interaction Diagram (fMn, fPn)
409 7.7 1589.786 0.75 5.7709 1192
394 17.3 1589.786 0.75 12.98 1192 1400
Interaction Diagram
379 26.4 1589.786 0.75 19.834 1192 17.3
40
364 35.0 1589.786 0.75 26.262 1192 1200
fPn (kN)

39.4
350 42.5 1559.512 0.75 31.885 1170 33
335 50.0 1491.462 0.75 37.517 1119 1000
320 57.0 1421.909 0.75 42.754 1066
305 63.5 1350.631 0.75 47.612 1013
291 69.1 1282.314 0.75 51.821 961.74 800
276 74.7 1206.893 0.75 56 905.17
261 79.8 1128.781 0.75 59.871 846.59 600
246 84.6 1047.488 0.75 63.46 785.62
232 88.5 960.9191 0.75 66.365 720.69
400
217 92.3 862.0283 0.75 69.244 646.52
202 94.8 765.0351 0.75 71.117 573.78
187 94.7 679.4817 0.75 71 509.61 200
173 94.0 594.39 0.75 70.476 445.79
158 92.7 496.02 0.75 69.493 372 0
143 90.2 402.77 0.75 67.616 302.08 0 10 20 30 40 50 60 70 80
128 85.9 324.52 0.75 64.449 243.39 fMn (kN.m)
114 81.1 245.26 0.75 60.847 183.95
99 74.9 150.70 0.77 57.358 115.35
84 67.8 62.96 0.84 57.171 53.127
69 58.2 -19.03 0.90 52.406 -17.13
55 46.9 -110.30 0.90 42.179 -99.27
40 29.8 -241.3 0.90 26.85 -217.2
25 14.3 -355.6 0.90 12.826 -320.1